Best UCB3I30SBB Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation
HB0313
UCB3I SERIES
INSTALLATION INSTRUCTIONS
INTENDED FOR DOMESTIC COOKING ONLY
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGES 8 AND 9.
READ AND SAVE THESE INSTRUCTIONS
BEST; Hartford, Wisconsin www.BestRangeHoods.com 800-558-1711
BEST; Drummondville, QC, Canada www.BestRangeHoods.ca 866-737-7770
23864 rev. 04
! !
2
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualified personnel in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guidelines and safety standards such as
those published by the National Fire Protection Association
(NFPA) and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE) and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vente
d
d outdoors.
7. To reduce the risk of fire or electric shock, do not use this unit
with any additional solid-state speed control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
10. All tempered glass can experience spontaneous breakage. If
broken, tempered glass falls out of it’s opening in interlocking
clumps. Tempered glass can, on occasion, break into large
shards rather than the classic tiny piece pattern.
11. When applicable local regulations comprise more
restrictive installation and/or certification requirements,
the aforementioned requirements prevail on those of this
document and the installer agrees to conform to these at his
own expense.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan, filters or in exhaust ducts.
d) Use proper pan size. Always use cookware appropriate for the
size of the surface element.
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Your hood motor has a thermal overload which will automatically
shut off the motors if it overheats. The motors will restart when
cooled down. If the motor(s) continues to shut off and restart,
have the hood serviced.
5. The minimum hood distance above cooktop must not be
less than 24". A maximum of 30" above cooktop is highly
recommended for best capture of cooking impurities. For a
gas range, the bottom of the hood MUST NOT BE LESS
than 30” above cooktop.
6. Two installers are recommended because of the large size and
weight of this unit.
7. To reduce the risk of fire and to properly exhaust air, be sure to
duct air outside — Do not exhaust air into spaces within walls
or ceiling or into attics, crawl space or garage.
8. Because of the high exhausting capacity of this unit, you
should make sure enough air is entering the house to replace
exhausted air by opening a window close to or in the kitchen.
9. Use with approved cord-connection kit only.
10. Please read specification label on product for further
information and requirements.
WARNING
!
CAUTION
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE
THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or
towels — This could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You own a Class ABC extinguisher and you know how to
operate it.
B. The fire is small and contained in the area where it started.
C. The fire department has been called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
WARNING
!
3
TABLE OF CONTENTS
1. I NSTALL DUCTWORK ................................................................................................................................................................3
2. PREPARE THE INSTALLATION .....................................................................................................................................................4
3. P
REPARE THE HOOD ............................................................................................................................................................4-5
4. INSTALL GLASS PANEL (WITHOUT GLASS MODELS ONLY) ..................................................................................................................5
5. INSTALL THE ADAPTER/DAMPER .................................................................................................................................................6
6. I
NSTALL THE HOOD .................................................................................................................................................................7
7. C
ONNECT WIRING ..................................................................................................................................................................7
8. REINSTALL BLOWER WHEEL AND BOTTOM PANEL ........................................................................................................................... 7
9. REINSTALL HYBRID FILTERS ......................................................................................................................................................8
10. LED LIGHTING ......................................................................................................................................................................8
11. CARE ..................................................................................................................................................................................8
12. OPERATION ..........................................................................................................................................................................9
13. WIRING DIAGRAM.................................................................................................................................................................10
14. SERVICE PA RT S ................................................................................................................................................................... 11
15. WARRANTY ........................................................................................................................................................................12
1. INSTALL DUCTWORK
Plan where and how the ductwork will be installed.
The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest,
straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around
the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated airflow. Refer to
the table at the botom of this page to help you plan the most efficient installation.
Install wall or roof cap; once done, ensure there is no leak in house insulation. Connect metal ductwork to cap and work back towards the
hood location. If 6” round ducts are installed, use a 3¼” x 10” to 6” transition positionned, if possible, 18” away from the adapter/damper.
Use 2” metal foil duct tape to seal the joints.
We recommend to install the hood at a minimum distance of 24” from an electric range and of 30” from a gas range.
Distances over 30” are at the installer and users discretion.
HOOD
3¼" X 10" DUCT
ROOF CAP
WALL
CAP
HH0142A
24" MINIMUM ABOVE
COOKING
SURFACE
(30" FOR GAS RANGE)
3¼" X 10"
A
DAPTER/DAMPER
HOOD
6" ROUND DUCT
ROOF CAP
WALL CAP
3¼" X 10" TO 6"
R
OUND TRANSITION
HH0222A
3¼" X 10"
A
DAPTER/DAMPER
24" MINIMUM ABOVE
COOKING
SURFACE
(30" FOR GAS RANGE)
3 ¼” X 10” MAXIMUM
DUCT LENGHT
6” ROUND MAXIMUM
DUCT LENGHT
ROOF OR WALL CAP
WITH DAMPER
ELBOW(S)*
(90° AND/OR 45°)
60
FT.- 1 0
50
FT.- 1 1
40
FT.- 1 2
- 50
FT.1 0
- 40
FT.1 1
- 30
FT.1 2
M
AXIMUM DUCT LENGHTS RECOMMENDED TO ACHIEVE 80% EXHAUST EFFICIENCY
*STANDARD ELBOWS
WITH 1” INTERNAL
RADIUS.
4
2. PREPARE THE INSTALLATION
NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the manufacturer.
Make sure that the following items are included:
- Hood
- Accessories:
2 hybrid filters
3¼” x 10” adapter/damper (located in one styrofoam end cap)
Parts bag (located in one styrofoam end cap) including:
1 wire clamp, 9 no. 8 x 1/2” screws, 2 wire connectors and 3 no. 6 x 1/2” standard screws
Parts sold separately:
- Ducts, elbows, wall or roof caps
- Transition 3¼” x 10” to 6” round (optional, for 6” round ducts installation only)
- Glass panel for UCB3I30SBN and UCB3I36SBN models (see service parts list on page 11)
NOTES: 1. During installation, protect countertop and/or cooktop.
2. If the bottom of the cabinet is recessed, attach four 1’ wide wood strips (not
included), as shown at right, in order to properly attach the hood to the
cabinet. The wood strips must be as thick as recess.
WARNING
!
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
HO0028A
CABINET BOTTOM
¾1¾1
10¼’’
5¼’’
1”
1”
1”
1”
Cut-out the openings for duct (A) and power cable (B), in cabinet or wall, according to the direction of discharge chosen. See figures below.
C
L
HD0407A
3½”
5¼” 5¼”
3”
B
1½” DIA.
A
7/8”
HORIZONTAL DISCHARGE
C
L
7/8’’
3½’’
5¼’’ 5¼’’
2¼’’
HD0566A
A
CABINET BOTTOM
2’’
1½’’
B
1/4’’
VERTICAL DISCHARGE
3. PREPARE THE HOOD
3.1 Lay the hood filters up on a table. Use a piece of cardboard to avoid damaging the
table or the hood. Remove tape on filters. Lift filters by pushing them towards the
back and flip them up, then set the filters aside.
HD0553
5
3.2 FOR 30” WIDE HOODS:
Remove the 7 screws (A only) retaining the bottom panel, and set aside.
FOR 36” WIDE HOODS:
Remove the 8 screws (A and B) retaining the bottom panel and set aside.
HO0246
A
B
3. PREPARE THE HOOD (CONT'D)
3.3 Using both hands, gently pull on the blower wheel to remove. Set blower wheel
aside.
HO0347
4.1 Carefully remove glass panel from its packaging.
Remove glass panel nuts (factory installed) from both studs and set aside.
4.2 Insert glass panel studs in hood front holes.
4.3 While holding glass panel, pre-tighten previously removed nuts by hand. Ensure glass panel is flush with top of hood and centered
from side-to-side.
Then, using a 3/8" socket, tighten nuts completely.
4. INSTALL GLASS PANEL (SBN MODELS ONLY)
The SBN hood models decorative glass panel is sold separately and has to be installed before completing the hood installation.
HD0556
NUT
STUD
6
Press the metal shutoff plate on a flat surface to completely flatten bent flange.
HO0245
Using both screws previously removed, install the metal shutoff plate on top of the hood.
HD0415
5. INSTALL THE ADAPTER/DAMPER (ALL MODELS)
The wall duct must be roughed-in to properly interface with the hood. Before performing the installation, make sure the adapter fits easily
in the duct. If this hood replaces an existing hood, please note that location of the air exhaust can vary from one manufacturer to another.
FOR HORIZONTAL DISCHARGE ONLY:
Turn the hood over and remove the metal shutoff plate from the back of the hood, by
removing both retaining screws. Set screws aside.
Fold down the foldable flange of the adapter/damper. This flange must be at 90° from the
remaining flanges. See picture beside.
HD0112
HO0244
SCREW LOCATIONS
Using two no. 6 x 1/2’ screws provided, secure the adapter/damper to the back of the hood.
Remove tape from damper flap.
Seal the adapter/damper to the hood using metal foil duct tape.
HO0178
TOP
BOTTOM
PIVOT
FOR VERTICAL DISCHARGE ONLY:
Using two no. 6 x 1/2” screws provided, secure the adapter/damper to the top of the hood.
Remove tape from damper flap.
Seal the adapter/damper to the hood using metal foil duct tape.
HO0179
SCREWS
PIVOT
7
6. INSTALL THE HOOD
6.1 Run power cable to installation location. Position the hood in its intended
location. Using a pen, mark the position of the screws (as shown at right).
Remove the hood.
6.2 Install the first four no. 8 x 1/2’ screws, leaving a 1/8’ gap (do not install screws nos. 5, 6, 7, 8 and 9 yet).
6.3 Install the wire clamp and insert the power cable in the hood. Place the hood under the cabinet, slide it in position and tighten the wire
clamp to secure the cable. Make sure the adapter/damper enters the duct opening. Tighten the first 4 screws completely, then add the
last screws (screws nos. 5, 6, 7, 8 and 9) in the center holes. Make sure the damper flap opens freely.
HD0554
1
2
563
4
8
9
7
7. CONNECT WIRING
WARNING
!
Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable
codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting
means to prevent power to be switched on accidentally.
HE0059
GROUND
SCREW
Connect cable to range hood wiring using included wire connectors.
Connect BLACK to BLACK, WHITE to WHITE and GREEN or BARE WIRE to GREEN
ground screw. DO NOT FORGET TO CONNECT THE GROUND.
8. REINSTALL BLOWER WHEEL AND BOTTOM PANEL
CAUTION
When reinstalling the blower wheel, make sure the small tab is aligned with the yellow label on the motor.
8.1 Reinstall blower wheel: Using both hands, gently push on
the blower wheel until secured.
8.2 Insert bottom panel in the back of the hood.
8.3 Secure bottom panel to the hood, using the 7 or 8 screws
previously removed in step 3.2.
HO0168
8
9. REINSTALL THE HYBRID FILTERS
CAUTION
Remove protective plastic film covering filters before reinstalling them.
Rest rear filters edge on filter springs in the range hood. Tilt up the filters into position.
Make sure filter tabs are securely engaged in range hood front edge slots after
installation.
HO0348
FILTER TABS
11. CARE
HYBRID FILTERS AND BOTTOM PANEL
The hybrid filters and the bottom panel should be cleaned frequently. Use a warm detergent solution.
Remove hybrid filters by pushing them towards the back of hood and rotating downward.
Clean all-metal filters in the diswasher using a non-phophate detergent. Discoloration of the filters may occur if using phosphate detergents,
or as a result of local water conditions — this will not affect filter performance. This discoloration is not covered by the warranty. To minimize
or prevent discoloration, hand wash filters using a mild detergent.
STAINLESS STEEL
Do:
Regularly wash with clean cloth or rag soaked with warm water
and mild soap or liquid dish detergent.
Always clean in the direction of original polish lines.
Always rinse well with clear water (2 or 3 times) after cleaning.
Wipe dry completely.
You may also use a specialized household stainless steel
cleaner.
Don’t:
Use any steel or stainless steel wool or any other scrapers to
remove stubborn dirt.
Use any harsh or abrasive cleansers.
Allow dirt to accumulate.
Let plaster dust or any other construction residues reach the
hood. During construction/renovation, cover the hood to make
sure no dust sticks to stainless steel surfaces.
WARNING
!
Before servicing or cleaning the unit, switch power off at service panel and lock service panel to prevent power
from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
10. LED LIGHTING
The lighting of this hood is produced by two LED modules (included).
WARNING
!
Do not touch LED modules during or soon after operation. Burns may occur. Cannot be replaced by any other type of light bulb
or LED module.
GLASS PANEL
Hot water with mild soap or glass cleaner is all that is usually needed.
When using mild soap, rinse with clear water. Wipe dry with a clean, soft cloth to avoid water marks.
Avoid when choosing a detergent:
- Any cleaners that contain bleach. They will attack stainless steel.
- Any products containing chloride, fluoride, iodide, bromide. They will deteriorate surfaces rapidly.
- Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc. They are highly explosive and should never
be used close to a range.
9
12. OPERATION
Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the
air after you turn off the range.
HC0052
A
B
CD
A. DELAY BUTTON/CONTROL LOCK (DOUBLE FUNCTION BUTTON):
i. When a blower speed is selected, press this button to activate the delay function. The delay button will light to its high intensity, then
to its mid intensity to indicate this function is activated; the selected blower speed button will alternate every 2 seconds from its high
intensity to its mid intensity. The blower will continue to operate for 5 minutes and will stop automatically. Selecting an other speed
while the delay function is activated will not deactivate the function or reset the timer. To cancel the delay function, press the delay
button once again, or press the selected speed button which will also turn the blower off.
ii. When blower is off, it is possible to lock the control interface in order to clean the glass panel.
To lock the control interface: Press and hold the button for 2 seconds. The button will light to its high intensity and flash three times,
it will then stay on its mid intensity to indicate that the control interface is locked.
To unlock the control interface: Press and hold the button for 2 seconds. The button will light to its high intensity and flash 3 times,
it will then fade out to its low intensity to indicate that the control interface is unlocked.
B. SPEED SELECTION BUTTONS:
Press the button corresponding to the desired blower speed (from 1 for low speed to 4 for high speed). The chosen speed button will
light to its high intensity then fade to its mid intensity. To turn off the blower, press once more on the corresponding blower speed
button; the button light will fade to its low intensity.
NOTE: When blower is off, pressing on blower speed 1 button will cause the blower to start on second speed for a very short lapse of time,
and then resume on speed 1.
C. MASTER ON/OFF:
When blower and lights are off, press this button to turn the hood on to the last memorized speed level. If there is no memorized
speed level, speed will be set at level 1 and light insensity at 3. To turn off the blower and the light simultaneously, press this button
once.
HEAT SENTRY™: The hood is equipped with a HEAT SENTRY thermostat. If blower is ON at a lower speed setting and excessive heat is
detected above the cooking surface, it turns the blower up to third speed. When the temperature level drops to normal,
the blower will return to its original setting.
NOTE: When Heat Sentry is activated, the “DELAY OFF” function is inactivated.
WARNING
!
The Heat Sentry can change the blower speed when excessive heat is detected above the cooking surface. If this
situation occurs and you must stop the blower, press on the third speed button or on the master ON/OFF button.
D. LIGHT BUTTON/BACKLIGHTING COLOR (DOUBLE FUNCTION BUTTON):
i. This button allows three different lighting levels according to your needs. Press once for full intensity, twice for intensity level 2, and
once more for nightlight. To turn off the lights, press once more.
If desired, when the lights are on, press and maintain the light button for 1 second; lights will be turned off.
NOTE: When only the lights are ON to any intensity and no interaction with the hood is detected for a 10-second period, the
7 buttons backlighting will fade to its low intensity, acting as a night light feature.
ii. When lights are off, pressing and holding this button for 1 second will switch the backlighting color from white to blue or from blue
to white (default backlighting color is white) and memorize it. The button will flash three times to indicate that the color change has
been made.
NOTE: Due to the particular sensitivity of the control interface, keep the glass panel clean as dirt and condensation may cause
erratic operation of the hood blower and/or lighting. If this situation occurs, wipe the glass panel and wait 90 seconds. Then,
adjust the blower and/or lighting at your convenience.
CAUTION
After a power failure or during the range hood power up, a 5-second booting sequence is executed. Wait for the
control backlighting to turn off before use.
NOTE: To decrease the maximum airflow from 600 CFM to 300 CFM, follow the instructions of the 300 CFM CRT kit (included with the
unit, envelope no. 23894, or order SV23894 part).
10
13. WIRING DIAGRAM
WARNING
!
Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable
codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting
means to prevent power from being switched on accidentally.
Line
Neutral
Ground
120 V AC
BLK BLACK
BLU BLUE
BRN BROWN
GRN GREEN
ORG ORANGE
RED RED
WHT WHITE
YEL YELLOW
COLOR CODE
16 Pins
LED driver
Input
Output
LED
LED
User interface
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
T1
FAN MOTOR
User Interface
J1
10VAC
J8
Aux.
Input
3
2
1
RP1
J3
Programmer
header
Triac Ext
J7
J11
12VDC
+
-
J4
Motor
Speed
J2
120V-Motor-Lamp
1
J10
J9 Serial Com
5
4
32
1
J5
Output
J6
Thermistor
2
3
4
5
1
2
3
4
1
2
1
2
1
2
3
4
1
2
1
2
3
PNK PINK
PPL PURPLE
HE0046A
YEL
BLK
WHT
WHT
RED
RED
RED
RED
BRN
BLU
ORG
WHT
RED
WHT
BLK
BLK 120
ORG 120
BLU 88
PPL 60
PNK 45
YEL 10
WHT 0
WHT 0
BRN
BLK
GRN
WHT
BLK
WHT
BLU
11
14. SERVICE PARTS
HL0448
1
2
3
4
5
6
7
8
9
10
11
REPLACEMENT PARTS AND REPAIRS
In order to ensure your unit remains in good working condition, you must use Broan-NuTone genuine replacement parts only.
Broan-NuTone genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable
certification standards and maintain a high standard of safety. Any third party replacement part used may cause serious damage and
drastically reduce the performance level of your unit, which will result in premature failing. Broan-NuTone recommends to contact a
certified service depot for all replacement parts and repairs.
KEY
NO.
PART NO.DESCRIPTION
WIDTHS
30" 36"
1
SV09953XX* GLASS PANEL 30” 1
SV09954XX* GLASS PANEL 36” 1
2 SV22427 E
LECTRONIC CONTROL 11
3 62612 LED MODULE 22
4 SV01766E WHEEL AND MOTOR 11
5 SV62053 HYBRID FILTER 15.875” X 14” x 0.5” 2 2
6 SV21189 POWER UNIT 11
7 SV07325 TRANSFORMER 11
8 62248 LED DRIVER AND CONNECTION HARNESS 11
9 SV02160 CAPACITOR 11
10 SV08548 R
OCKER SWITCH 11
11 SV13296 ADAPTER/DAMPER 11
** SV23894 CRT KIT 300 CFM (OPTIONAL)11
** SV05869 BEST LOGO 11
** SV23864 INSTALLATION MANUAL 11
** SV06751 HARDWARE BAG 11
*P
ART NUMBER ACCORDING TO GLASS PANEL COLOR.
PLEASE CONTACT CUSTOMER SERVICE OR VISIT WEB SITE.
**ITEM NOT SHOWN.
12
15. WARRANTY
FIVE-YEAR LIMITED WARRANTY FOR BEST
®
PRODUCTS
Warranty Period and Exclusions: Broan-NuTone, LLC (the “Company”) warrants to the consumer purchaser of its product (“you”) that the product (the
“Product”) will be free from material defects in the materials or its workmanship for a period of five (5) years from the date of original purchase (or such
longer period as may be required by applicable law) or a period of two (2) years from the date of service for any labor provided on the Product.
The limited warranty period for any replacement parts provided by the Company and for any Products repaired or replaced under this limited warranty shall
be the remainder of the original warranty period (or such longer period as may be required by applicable law).
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES AND BULBS, FUSES, FILTERS, DUCTS, ROOF CAPS, WALL CAPS
AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service, (b) normal wear and tear, (c) any Products or
parts which have been subject to misuse, abuse, abnormal usage, negligence, accident, improper or insufficient maintenance, storage or repair (other than
repair by the Company), (d) damage caused by faulty installation, or installation or use contrary to recommendations or instructions, (f) damage caused by
exposure to salt air, (g) damage in transit, (h) natural wear of finish, (i) Products in commercial or nonresidential use, (j) damage caused by fire, flood or
other act of God, or (k) Products with altered, defaced or removed serial numbers. This warranty covers only Products sold to consumers in North America.
This warranty supersedes all prior warranties and, subject to applicable law, is not transferable from the original consumer purchaser.
No Other Warranties: This Limited Warranty contains the Company’s sole obligation and your sole remedy for defective Products. The foregoing warranties
are exclusive and in lieu of any other warranties and conditions, express or implied. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THE
COMPANY DISCLAIMS AND EXCLUDES ALL OTHER EXPRESS WARRANTIES AND CONDITIONS, AND DISCLAIMS AND EXCLUDES ALL WARRANTIES
AND CONDITIONS IMPLIED BY LAW, INCLUDING WITHOUT LIMITATION THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
To the extent that applicable law prohibits the exclusion of implied warranties or conditions, the duration of any applicable implied warranty or condition
is limited to the period specified for the express warranty above. Some jurisdictions (which may include the Province of Quebec or specific US states) do
not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Any oral or written description of the Product is
for the sole purpose of identifying it and shall not be construed as an express warranty.
Whenever possible, each provision of this Limited Warranty shall be interpreted in such manner as to be effective and valid under applicable law, but if any
provision is held to be prohibited or invalid, such provision shall be ineffective only to the extent of such prohibition or invalidity, without invalidating the
remainder of such provision or the other remaining provisions of the Limited Warranty.
Remedy: During the applicable limited warranty period, the Company will, at its option, provide replacement parts for, or repair or replace, without charge,
any Product or part thereof, to the extent the Company finds it to be covered by and in breach of this limited warranty under normal use and service. The
Company will ship the repaired or replaced Product or replacement parts to you at no charge. You are responsible for all costs for removal, reinstallation
and shipping, insurance or other freight charges incurred in the shipment of the Product or part to the Company. If you must send the Product or part
to the Company, as instructed by the Company, you must properly pack the Product or part—the Company is not responsible for damage in transit. The
Company reserves the right to utilize reconditioned, refurbished, repaired or remanufactured Products or parts in the warranty repair or replacement
process. Such Products and parts will be comparable in function and performance to an original Product or part and warranted for the remainder of the
original warranty period (or such longer period as may be required by applicable law).
Company reserves the right, in its sole discretion, to refund the money actually paid by you for the Product. If the Product or component is no longer
available, replacement may be made with a similar product of equal or greater value, at Company’s sole discretion. This is your sole and exclusive remedy
for breach of this limited warranty.
Exclusion of Damages: THE COMPANY’S OBLIGATION TO PROVIDE REPLACEMENT PARTS, OR REPAIR OR REPLACE, AT THE COMPANY’S OPTION,
SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY AND THE COMPANY’S SOLE AND EXCLUSIVE OBLIGATION. THE
COMPANY SHALL NOT BE LIABLE FOR INCIDENTAL, INDIRECT, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH
THE PRODUCT, ITS USE OR PERFORMANCE.
Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply
to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from jurisdiction to jurisdiction. The disclaimers,
exclusions, and limitations of liability under this warranty will not apply to the extent prohibited by applicable law.
This warranty covers only replacement or repair of defective Products or parts thereof at the Company’s main facility and does not include the cost of field
service travel and living expenses.
Any assistance the Company provides to or procures for you outside the terms, limitations or exclusions of this limited warranty will not constitute a waiver
of such terms, limitations or exclusions, nor will such assistance extend or revive the warranty. The Company will not reimburse you for any expenses
incurred by you in repairing or replacing any defective Product, except for those incurred with the Company’s prior written permission.
How to Obtain Warranty Service: To qualify for warranty service, you must (a) notify the Company at the address or telephone number stated below within
seven (7) days of discovering the covered defect, (b) give the model number and part identification and (c) describe the nature of any defect in the Product
or part. At the time of requesting warranty service, you must present evidence of the original purchase date. If you cannot provide a copy of the original
written limited warranty, then the terms of the Company’s most current written limited warranty for your particular product will control.
PRODUCT SPECIFICATIONS
All illustrations and specifications in this catalog are based on the latest product information available at time of production. Broan-NuTone, LLC and
BEST® reserves the right to make changes at any time, without notice, in prices, colors, materials, equipment, specifications and models, place of
manufacture and to discontinue models or equipment.
Best
Broan-NuTone, LLC- 926 W. State Street, Hartford, WI 53207 1-800-637-1453
Best®, 550 Lemire Blvd., Drummondville, QC, Canada (1-866-737-7770) www.bestrangehoods.com
HB0313
SÉRIE UCB3I
GUIDE D’INSTALLATION
23864 rév. 04
CONÇUE UNIQUEMENT POUR LA CUISSON DOMESTIQUE
INSTALLATEUR : LAISSER CE GUIDE AU PROPRIÉTAIRE.
PROPRIÉTAIRE : DIRECTIVES D’UTILISATION ET D’ENTRETIEN
EN PAGES 8 ET 9.
LIRE ET CONSERVER CES DIRECTIVES
! !
BEST; Hartford, Wisconsin www.BestRangeHoods.com 800 558-1711
BEST; Drummondville, QC, Canada www.BestRangeHoods.ca 866 737-7770
2
AFIN DE RÉDUIRE LES RISQUES D’INCENDIE,
D’ÉLECTROCUTION OU DE BLESSURES CORPORELLES,
SUIVEZ LES DIRECTIVES SUIVANTES :
1. N’utilisez cet appareil que de la façon prévue par le
manufacturier. Si vous avez des questions, contactez le
manufacturier à l’adresse et au numéro de téléphone indiqués
dans la garantie.
2. Avant de réparer ou de nettoyer l’appareil, couper l’alimentation
électrique en verrouillant le panneau de distribution afin
d’éviter sa remise en marche accidentelle. Si le panneau de
distribution ne peut être verrouillé, y fixer un avertissement en
évidence, telle qu’une étiquette de couleur vive.
3. Les travaux d’installation et de raccordement électrique doivent
être effectués par une personne qualifiée, conformément aux
codes et standards de construction, incluant ceux concernant
la protection contre les incendies.
4. Une quantité d’air adéquate est requise afin d’assurer une
bonne combustion et l’évacuation des gaz par la cheminée
dans le cas des appareils alimentés au gaz, afin de prévenir
les retours de cheminée. Conformez-vous aux instructions et
aux standards de sécurité des manufacturiers d’équipement
de chauffage, tel que publiés par la National Fire Protection
Association (NFPA), et l’American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), ainsi
que les responsables des codes locaux.
5. Veillez à ne pas endommager le câblage électrique ou d’autres
équipements non apparents lors de la découpe ou du perçage
du mur ou du plafond.
6. L’évacuation des ventilateurs avec conduits doit toujours se
faire à l’extérieur.
7. Afin de réduire le risque d’incendie ou d’électrocution, ne
pas utiliser cet appareil avec une commande de vitesse à
semi-conducteur additionnelle.
8. Afin de réduire le risque d’incendie, n’utilisez que des conduits
en métal.
9. Cet appareil doit être relié à une mise à la terre.
10.Tout verre trempé peut se briser spontanément. En cas de bris,
il tombera hors de son emplacement en s’égrenant. Le verre
trempé peut, à l’occasion, se briser en gros morceaux plutôt
qu’en petites particules.
11. Lorsqu’une réglementation est en vigueur localement et qu’elle
comporte des exigences d’installation et/ou de certification
plus restrictives, lesdites exigences prévalent sur celles de ce
document et l’installateur entend s’y conformer à ses frais.
AFIN DE RÉDUIRE LES RISQUES DE FEU DE CUISINIÈRE :
a) Ne jamais laisser les appareils de cuisson sans surveillance
lorsqu’ils sont réglés à feu vif. Les débordements engendrent de
la fumée et des déversements graisseux pouvant s’enflammer.
Chauffez l’huile lentement, à feu doux ou moyen.
b) Toujours mettre la hotte en marche lorsque vous cuisinez à
feu vif ou que vous cuisinez des mets flambés (par exemple :
crêpes Suzette, cerises jubilée, steaks au poivre flambés).
c) Nettoyez régulièrement la (les) roue(s) du ventilateur. Ne
laissez pas la graisse s’accumuler sur le ventilateur, les filtres
ou les conduits d’évacuation.
d) Utilisez le bon format de casserole. Servez-vous toujours de
casseroles et d’ustensiles appropriés à la dimension de la
surface chauffante.
1. Pour une utilisation à l’intérieur seulement.
2. Pour usage domestique seulement. Ne pas utiliser pour évacuer
des vapeurs ou des matières dangereuses ou explosives.
3. Afin d’éviter tout dommage au moteur et de débalancer ou de
rendre bruyante la roue du moteur, garder votre appareil à l’abri
des poussières de placoplâtre et de construction/rénovation, etc.
4. Le moteur de votre hotte possède une protection thermique
qui arrêtera automatiquement le fonctionnement du moteur s’il
surchauffe. Le moteur redémarrera automatiquement une fois
refroidi. Si le moteur continue de s’arrêter et de redémarrer,
faites-le vérifier.
5. La distance minimale entre le bas de votre hotte et la surface
de cuisson ne doit pas être inférieure à 24 po. Un maximum de
30po au-dessus du plan de cuisson est fortement recommandé
pour une meilleure évacuation des odeurs de cuisine. Pour
une cuisinière au gaz, le bas de votre hotte encastrable NE
DOIT PAS ÊTRE INFÉRIEUR à 30 po au-dessus de la surface
de cuisson.
6. Deux installateurs sont recommandés lors de l’installation en
raison de la grande dimension et le poids de cet appareil.
7. Afin de réduire les risques d’incendie, assurez-vous d’évacuer
l’air à l’extérieur. Ne pas évacuer l’air dans des espaces
restreints comme l’intérieur des murs ou plafond ou dans le
grenier, faux plafond ou garage.
8. En raison de la grande capacité d’évacuation de cet appareil,
il est recommandé d’ouvrir une fenêtre dans ou près de la
cuisine afin de remplacer l’air évacué.
9. Cette hotte ne doit être utilisée qu’avec un ensemble de cordon
d’alimentation approuvé.
10. Veuillez consulter l’autocollant apposé à l’intérieur du produit
pour plus d’information ou autres exigences.
AFIN D’ÉVITER TOUT RISQUE DE BLESSURES LORS D’UN
FEU DE CUISINIÈRE, SUIVEZ CES DIRECTIVES* :
1. Étouffez les flammes avec un couvercle hermétique, une
tôle à biscuits ou un plateau métallique et ensuite, éteindre
le brûleur. PRENEZ SOIN D’ÉVITER LES BRÛLURES. SI
LES FLAMMES NE S’ÉTEIGNENT PAS IMMÉDIATEMENT,
ÉVACUEZ LES LIEUX ET APPELEZ LES POMPIERS.
2. NE PRENEZ JAMAIS UNE CASSEROLE EN FLAMMES
DANS VOS MAINS – Vous pourriez subir des brûlures.
3. N’UTILISEZ PAS D’EAU, incluant linge à vaisselle ou serviette
mouillés – ceci pourrait occasionner une violente explosion.
4. N’utilisez un extincteur QUE DANS LE CAS OÙ :
A. Vous savez qu’il s’agit d’un extincteur de classe ABC et
que vous en connaissez le fonctionnement.
B. Le feu est petit et limité à l’endroit où il a débuté.
C. Les pompiers ont été avisés.
D. Vous pouvez combattre l’incendie en ayant accès à une
sortie de secours.
*Tirées du Kitchen Fire Safety Tips publié par la NFPA.
AVERTISSEMENT
!
AVERTISSEMENT
!
ATTENTION
3
TABLE DES MATIÈRES
1. I NSTALLATION DES CONDUITS ....................................................................................................................................................3
2. PRÉPARATION DE LINSTALLATION ..............................................................................................................................................4
3. P
RÉPARATION DE LA HOTTE ..................................................................................................................................................4-5
4. INSTALLATION DE LA FADE DE VERRE (MODÈLES SANS FADE DE VERRE SEULEMENT ) .....................................................................5
5. INSTALLATION DE LADAPTATEUR/VOLET .......................................................................................................................................6
6. I
NSTALLATION DE LA HOTTE ......................................................................................................................................................7
7. B
RANCHEMENT ÉLECTRIQUE ....................................................................................................................................................7
8. REMISE EN PLACE DE LA ROUE ET DU PANNEAU INFÉRIEUR.............................................................................................................7
9. REMISE EN PLACE DES FILTRES HYBRIDES ..................................................................................................................................8
10. ÉCLAIRAGE À DEL ................................................................................................................................................................8
11. ENTRETIEN ...........................................................................................................................................................................8
12. FONCTIONNEMENT .................................................................................................................................................................9
13. SCHÉMA ÉLECTRIQUE ...........................................................................................................................................................10
14. PIÈCES DE REMPLACEMENT ................................................................................................................................................... 11
15. GARANTIE ..........................................................................................................................................................................12
1. INSTALLATION DES CONDUITS
Planifier à quel endroit et de quelle façon les conduits seront installés.
Le conduit reliant cette hotte à l’extérieur du bâtiment a un effet direct sur le débit de l’air, le bruit généré et la consommation d’énergie
de son ventilateur. Pour obtenir le meuilleur rendement, utiliser un conduit le plus droit et le plus court possible, en évitant de raccorder le
ventilateur de la hotte à un conduit de format plus petit que recommandé. De l’isolant autour du conduit peut réduire la perte d’énergie et
empêcher la croissance de moisissures. Les hottes installées avec un conduit préexistant pourraient ne pas atteindre leur débit nominal.
En utiliser le moins possible. Veuillez vous référer au tableau en bas de page pour vous aider à planifier l’installation la plus efficace.
Installer un capuchon de toit ou de mur, puis s’assurer qu’il n’y a aucune fuite dans l’isolation de la maison. Relier le conduit de métal de
format adéquat (3¼ po x 10 po ou 6 po rond) au capuchon, puis acheminer le conduit jusqu’à la hotte. Si un conduit rond de 6 po est utilisé,
utiliser aussi une transition de 3¼ po x 10 po à 6 po. Il est recommandé d’installer cette transition à 18 po de l’adaptateur/volet. Sceller les
joints avec du ruban adhésif de métal de 2 po de largeur.
Il est recommandé d’installer la hotte à une distance minimale de 24 po au-dessus d’une cuisinière électrique et de 30 po
au-dessus d’une cuisinière au gaz.
Une distance de plus de 30 po demeure à la discrétion de l’installateur et de l’utilisateur.
HOTTE
CONDUIT
DEPO X 10 PO
CAPUCHON DE TOIT
CAPUCHON
DE
MUR
HH0142F
MINIMUM DE 24 PO
AU
-DESSUS DE LA
SURFACE
DE CUISSON
(30 PO POUR UNE
CUISINIÈRE AU GAZ)
ADAPTATEUR/VOLET
DE
PO X 10 PO
HOTTE
HH0222F
CAPUCHON DE TOIT
CONDUIT ROND DE 6 PO
TRANSITION
PO X 10 PO
À 6 PO ROND
A
DAPTATEUR/VOLET
DE
PO X 10 PO
MINIMUM DE 24 PO
AU
-DESSUS DE LA
SURFACE
DE CUISSON
(30 PO POUR UNE
CUISINIÈRE AU GAZ)
C
APUCHON
DE
MUR
LONGUEUR MAXIMALE DE
CONDUIT DE 3¼ po X 10 po
LONGUEUR MAXIMALE DE
CONDUIT DE 6 PO ROND
CAPUCHON DE MUR OU
DE TOIT AVEC CLAPET
COUDE(S)* DE 90°
ET/OU DE 45°
60
PI -10
50
PI -11
40
PI -12
- 50
PI 10
- 40
PI 11
- 30
PI 12
L
ONGUEURS MAXIMALES DE CONDUIT RECOMMANDÉES POUR OBTENIR UNE EFFICACITÉ DÉVACUATION DE 80 %.
*C
OUDES STANDARD
DE RAYON INTERNE
DE 1 PO.
4
2. PRÉPARATION DE L’INSTALLATION
NOTE : Avant de commencer l’installation, vérifier le contenu de la boîte. Si des pièces sont manquantes ou endommagées, contacter le
manufacturier.
S’assurer que les éléments suivants sont inclus :
- Hotte
- Accessoires :
2 filtres hybrides
Adaptateur/volet de 3¼ po x 10 po (situé dans un embout en styromousse)
Sac de pièces (situé dans un embout en styromousse) incluant :
1 serre-fil, 9 vis n° 8 x 1/2 po, 2 capuchons de connexion et 3 vis standard n° 6 x 1/2 po
Pièces vendues séparément :
- Conduits, coudes, capuchons de mur ou de toit
- Transition 3¼ po x 10 po à 6 po rond (optionnelle, pour une installation avec conduit rond de 6 po seulement)
- Façades de verre pour les modèles UCB3I30SBN et UCB3I36SBN (voir la liste des pièces de remplacement en page 11)
NOTES : 1. Protéger la surface de cuisson et le comptoir de cuisine pendant l’installation.
2. Si le fond de l’armoire est en retrait, y fixer 4 languettes de bois de 1 po
de largeur (non incluses), pour combler l’espace afin de bien retenir la
hotte à l’armoire. Voir ci-contre pour le positionnement des languettes.
AVERTISSEMENT
!
Il est recommandé de porter des lunettes et des gants de sécurité lors de l’installation, de l’entretien et de la réparation de cet
appareil.
HO0028F
DESSOUS D’ARMOIRE
¾ PO1¾ PO1
10¼ PO
PO
1 PO
1 PO
1 PO
1 PO
Découper, dans l’armoire ou le mur, les ouvertures pour le conduit (A) et le fil d’alimentation électrique (B), selon l’évacuation choisie
(horizontale ou verticale). Voir les illustrations ci-dessous.
C
L
HD0407F
PO
POPO
3 PO
B
PO DIA.
A
7/8 PO
ÉVACUATION HORIZONTALE
C
L
7/8 PO
PO
POPO
HD0566F
A
DESSOUS D’ARMOIRE
1/4 PO
2 PO
PO
B
PO
ÉVACUATION VERTICALE
3. PRÉPARATION DE LA HOTTE
3.1 Poser la hotte à plat sur une table, filtres vers le haut. Placer au préalable un
morceau de carton pour éviter d’endommager la table et la hotte. Retirer le ruban
adhésif des filtres. Soulever les filtres en les poussant vers l’arrière et en les
dégageant de la hotte, puis les mettre de côté.
HD0553
5
3. PRÉPARATION DE LA HOTTE (SUITE)
3.2 POUR LES HOTTES DE 30 PO :
Retirer les 7 vis de retenue du panneau inférieur (A seulement) et les mettre de côté.
POUR LES HOTTES DE 36 PO :
Retirer les 8 vis de retenue du panneau inférieur (A et B) et les mettre de côté.
HO0246
A
B
3.3 À deux mains, tirer doucement sur la roue du ventilateur afin de la retirer. Mettre la
roue de côté.
HO0347
4.1 Retirer délicatement la façade de verre de son emballage.
Retirer les deux écrous des goujons de la façade de verre (installés en usine) et les mettre de côté.
4.2 Insérer les goujons de la façade de verre dans les trous du devant de la hotte.
4.3 Tout en maintenant la façade de verre, pré-serrer à la main les écrous précédemment retirés. S’assurer que la façade de verre est à
égalité avec le dessus de la hotte et centrée d’un côté à l’autre. À l’aide d’une douille 3/8 po, serrer complètement les écrous.
4. INSTALLATION DE LA FAÇADE DE VERRE (MODÈLES SANS FAÇADE DE VERRE SEULEMENT)
La façade de verre décorative des modèles de hotte SBN est vendue séparément et doit être installée avant de poursuivre l’installation.
HD0556
ÉCROU
GOUJON
6
Redresser le côté plié de la plaque métallique en appuyant celle-ci sur une surface plane.
HO0245
À l’aide des 2 vis retirées précédemment, fixer la plaque métallique sur le dessus de
la hotte.
HD0415
5. INSTALLATION DE LADAPTATEUR/VOLET (TOUS LES MODÈLES)
Le conduit doit être bien préparé pour recevoir l’adaptateur. Avant d’installer la hotte, s’assurer que l’adaptateur entre aisément à l’intérieur du
conduit. Si cette hotte en remplace une autre, veuillez noter que la localisation de la sortie de l’air peut varier d’un manufacturier à l’autre.
ÉVACUATION HORIZONTALE SEULEMENT :
Retourner la hotte et dévisser les 2 vis retenant la plaque métallique à l’arrière de la hotte.
Mettre les vis de côté.
Plier le rebord pliable de l’adaptateur/volet de façon à ce qu’il se situe à 90° par rapport aux
autres rebords. Voir la photo ci-contre.
HD0112
HO0244
EMPLACEMENT DES VIS
À l’aide des deux vis n° 6 x 1/2 po (fournies), fixer l’adaptateur/volet à l’arrière de la hotte.
Retirer le ruban adhésif sur le volet de l’adaptateur.
Sceller l’adaptateur/volet à la hotte à l’aide de ruban adhésif de métal.
HO0178
DESSUS
DESSOUS
PIVOT
ÉVACUATION VERTICALE SEULEMENT :
À l’aide des deux vis n° 6 x 1/2 po (fournies), fixer l’adaptateur/volet sur le dessus de la
hotte. Retirer le ruban adhésif sur le volet de l’adaptateur.
Sceller l’adaptateur/volet à la hotte à l’aide de ruban adhésif de métal.
HO0179
VIS
PIVOT
7
6. INSTALLATION DE LA HOTTE
6.1 Passer le fil d’alimentation électrique jusqu’à l’endroit de l’installation.
Placer la hotte à son emplacement. À l’aide d’un crayon, marquer la
position des vis (tel qu’il est illustré ci-contre). Retirer la hotte.
6.2 Visser quatre vis n° 8 x 1/2 po en laissant un espace de 1/8 po (ne pas installer tout de suite les vis n
os
5, 6, 7, 8 et 9).
6.3 Installer le serre-fil et passer le cordon d’alimentation électrique dans la hotte. Placer la hotte sous l’armoire, la glisser en position
et serrer le serre-fil pour maintenir le cordon en place. S’assurer que l’adaptateur entre dans le conduit. Visser complètement les
4 premières vis, puis ajouter les dernières vis (n
os
5, 6, 7, 8 et 9). S’assurer que le volet de l’adaptateur s’ouvre librement.
HD0554
1
2
563
4
8
9
7
7. BRANCHEMENT ÉLECTRIQUE
AVERTISSEMENT
!
Risque d’électrocution. Le raccordement électrique doit être effectué par du personnel qualifié conformément aux codes et aux
standards. Avant d’effectuer le branchement, coupez l’alimentation électrique au tableau de distribution principal et verrouillez
ce dernier pour éviter une mise en marche accidentelle.
HE0059
VIS DE MISE
À LA TERRE
Connecter les fils à la hotte en utilisant les capuchons de connexion fournis.
Connecter le NOIR au NOIR, le BLANC au BLANC et le VERT ou FIL DÉNUDÉ à
la vis VERTE de mise à la terre. NE PAS OUBLIER DE CONNECTER LA MISE À
LA TERRE.
8. REMISE EN PLACE DE LA ROUE ET DU PANNEAU INFÉRIEUR
ATTENTION
Lors de la réinstallation de la roue du ventilateur, s’assurer que son ergot est aligné avec l’étiquette jaune du moteur.
8.1 Remettre en place la roue du ventilateur : à deux mains,
pousser doucement la roue jusqu’à ce qu’elle soit bien
en place.
8.2 Insérer le panneau inférieur au dos de la hotte.
8.3 Fixer le panneau inférieur à la hotte à l’aide des 7 ou des 8
vis précédemment retirées à l’étape 3.2.
HO0168
8
9. REMISE EN PLACE DES FILTRES HYBRIDES
ATTENTION
Retirer le film de plastique protecteur des filtres avant de les réinstaller.
Appuyer le rebord arrière des filtres sur les ressorts de filtre à l’intérieur de la hotte.
Incliner chaque filtre vers le haut jusqu’à ce que que les languettes soient bien
engagées dans les fentes du rebord avant de la hotte. S’assurer que les filtres sont
bien en place après l’installation.
HO0348
LANGUETTES
11. ENTRETIEN
FILTRES HYBRIDES ET PANNEAU INFÉRIEUR
Les filtres et le panneau inférieur doivent être nettoyés régulièrement. Utiliser de l’eau chaude additionnée de détergent. Pousser les filtres
vers l’arrière de la hotte, puis les abaisser afin de les retirer.
Nettoyer les filtres métalliques au lave-vaisselle avec un détergent sans phosphate. L’utilisation d’un détergent avec phosphates, de même
que la teneur en minéraux de l’eau, peut occasionner une décoloration des filtres, ce qui n’affectera en rien leur capacité de filtration. Cette
décoloration n’est pas couverte par la garantie. Afin de prévenir ou de limiter la décoloration, laver les filtres à la main avec un détergent doux.
ACIER INOXYDABLE
À faire :
• Laver régulièrement les surfaces à l’aide d’un chiffon ou d’un
linge propre imbibé d’eau tiède et de savon doux ou de détergent
liquide à vaisselle.
Toujours nettoyer dans le sens du polissage.
• Toujours bien rincer avec de l’eau claire (de 2 à 3 fois) et essuyer
complètement.
Un nettoyant domestique conçu spécialement pour l’acier
inoxydable peut aussi être utilisé.
À ne pas faire :
• Ne pas utiliser de laine d’acier ou d’acier inoxydable ou tout
autre grattoir pour enlever la saleté tenace.
Ne pas utiliser une poudre nettoyante abrasive ou rugueuse.
Ne pas laisser la saleté s’accumuler.
• Ne pas laisser la poussière de plâtre ou tout autre résidu de
construction atteindre la hotte. Couvrir la hotte pour la durée
des travaux afin de s’assurer qu’aucune poussière n’atteint
la hotte.
AVERTISSEMENT
!
Avant de nettoyer ou de réparer l’appareil, coupez le courant au panneau de distribution et verrouillez-en l’accès afin d’éviter
sa remise en marche accidentelle. Si le panneau de distribution ne peut être verrouillé, y apposer un avertissement bien en
évidence, comme une étiquette de couleur vive.
10. ÉCLAIRAGE À DEL
L’éclairage de cette hotte est produit par 2 modules DEL (inclus).
AVERTISSEMENT
!
Ne pas toucher aux modules DEL durant ou peu après leur utilisation. Peuvent causer des brûlures. Ne peuvent être remplacées
par aucun autre type d’ampoule ou de module à DEL.
FAÇADE DE VERRE
De l’eau chaude et un savon doux ou un nettoyant à vitres suffisent.
Si vous utilisez un savon doux, rincer à l’eau claire. Essuyer à l’aide d’un linge propre et doux pour éviter les stries.
À éviter lors du choix d’un détergent :
- Tous produits nettoyants contenant des agents de blanchiment; ils attaqueront l’acier inoxydable.
- Tous produits contenant du chlorure, du fluorure, de l’iode ou du bromure; ils détérioreront rapidement les surfaces.
- Tous produits combustibles utilisés pour le nettoyage : acétone, alcool, éther, benzène, etc.; ils sont grandement explosifs et ne
devraient jamais être utilisés près d’une cuisinière.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Best UCB3I30SBB Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation