Stahl 8571 Mode d'emploi

Taper
Mode d'emploi
SolConeX
Flange socket, 30 A
8571/25 series
North American
operating instructions
Additional languages r-stahl.com
DE
US
FR
IT
ES
RU
NL
DK
SE
FI
PT
GR
PL
CZ
SK
HU
SL
RO
BG
LV
LT
EE
CH
KR
CN
– Save for future use! –
Contents
2
DE
US
FR
IT
ES
RU
NL
DK
SE
FI
PT
GR
PL
CZ
SK
HU
SL
RO
BG
LT
EE
CH
KR
CN
SolConeX
Flange socket, 30 A
8571/25 series
Contents
1 General Information .............................................................................................3
1.1 Manufacturer........................................................................................................3
1.2 Information regarding the Operating Instructions.................................................3
1.3 Further Documents ..............................................................................................3
1.4 Conformity with Standards and Regulations........................................................3
2 Explanation of Symbols .......................................................................................4
2.1 Symbols used in these Operating Instructions.....................................................4
2.2 Warning Notes .....................................................................................................4
2.3 Symbols on the Device ........................................................................................5
3 Safety Notes ........................................................................................................5
3.1 Operating Instructions Storage ............................................................................5
3.2 Personnel Qualification........................................................................................5
3.3 Safe Use ..............................................................................................................6
3.4 Specific Conditions of Use...................................................................................7
3.5 Modifications and Alterations...............................................................................7
4 Function and Device Design................................................................................8
4.1 Function ...............................................................................................................8
5 Technical Data.....................................................................................................8
6 Transport and Storage.......................................................................................16
7 Mounting and Installation...................................................................................17
7.1 Dimensions/Fastening Dimensions....................................................................17
7.2 Mounting/Dismounting, Operating Position........................................................18
7.3 Installation..........................................................................................................19
8 Commissioning ..................................................................................................21
9 Operation ...........................................................................................................21
10 Maintenance, Overhaul, Repair .........................................................................22
10.1 Maintenance ......................................................................................................22
10.2 Overhaul ............................................................................................................22
10.3 Repair ................................................................................................................22
10.4 Returning the Device .........................................................................................23
11 Cleaning.............................................................................................................23
12 Disposal .............................................................................................................23
13 Accessories and Spare Parts.............................................................................23
294417 / 8571665300
2022-07-28·IO00·III·en·00
General Information
3
DE
US
FR
IT
ES
RU
NL
DK
SE
FI
PT
GR
PL
CZ
SK
HU
SL
RO
BG
LV
LT
EE
CH
KR
CN
SolConeX
Flange socket, 30 A
8571/25 series
1 General Information
1.1 Manufacturer
1.2 Information regarding the Operating Instructions
The original instructions are the American edition.
They are legally binding in all legal affairs.
1.3 Further Documents
SolConeX connectors data sheet
Mounting instructions for auxiliary contacts
For documents in other languages, see r-stahl.com.
1.4 Conformity with Standards and Regulations
Certificates for the USA and Canada can be downloaded via the following link:
https://r-stahl.com/en/global/support/downloads/.
R. STAHL Schaltgeräte GmbH
Am Bahnhof 30
74638 Waldenburg
Germany
R. STAHL, INC.
13259 N. Promenade Blvd.
Stafford, TX 77477
USA
Tel.:
Fax:
Internet:
E-mail:
+49 7942 943-0
+49 7942 943-4333
r-stahl.com
info@r-stahl.com
Tel.:
Fax:
Internet:
E-mail:
+1 800 782-4357
+1 281 313-9302
r-stahl.com
R. STAHL Ltd.
#303, 8925-51 Avenue
Edmonton, AB T6E 5J3
Canada
Tel.:
Fax:
Internet:
E-mail:
+1 877 416 4302
+1 780 469 5525
r-stahl.com
ID no.: 294417 / 8571665300
Publication code: 2022-07-28·IO00·III·en·00
Explanation of Symbols
4294417 / 8571665300
2022-07-28·IO00·III·en·00
DE
US
FR
IT
ES
RU
NL
DK
SE
FI
PT
GR
PL
CZ
SK
HU
SL
RO
BG
LV
LT
EE
CH
KR
CN
SolConeX
Flange socket, 30 A
8571/25 series
2 Explanation of Symbols
2.1 Symbols used in these Operating Instructions
2.2 Warning Notes
Warning notes must be observed under all circumstances, in order to minimise the risk
resulting from design engineering and operation. The warning notes have the following
structure:
Signalling word: DANGER, WARNING, CAUTION, NOTICE
Type and source of danger/damage
Consequences of danger
Taking countermeasures to avoid the danger or damage
Symbol Meaning
Tips and recommendations on the use of the device
General hazard
Danger due to explosive atmosphere
DANGER
Danger to persons
Non-compliance with the instruction results in severe or fatal injuries to
persons.
WARNING
Danger to persons
Non-compliance with the instruction can result in severe or fatal injuries
to persons.
CAUTION
Danger to persons
Non-compliance with the instruction can result in light injuries to
persons.
NOTICE
Avoiding material damage
Non-compliance with these instructions can result in material damage to the
device and/or its surroundings.
294417 / 8571665300
2022-07-28·IO00·III·en·00
Safety Notes
5
DE
US
FR
IT
ES
RU
NL
DK
SE
FI
PT
GR
PL
CZ
SK
HU
SL
RO
BG
LV
LT
EE
CH
KR
CN
SolConeX
Flange socket, 30 A
8571/25 series
2.3 Symbols on the Device
3 Safety Notes
3.1 Operating Instructions Storage
Carefully read the operating instructions.
Store the operating instructions at the mounting location of the device.
Observe applicable documents and operating instructions of the devices to be
connected.
3.2 Personnel Qualification
All activities on the device may only be performed by a qualified specialist.
This primarily applies to work in the following areas:
Project engineering
Mounting/dismounting the device
(Electrical) installation
• Commissioning
Maintenance, repair, cleaning
The specialist who performs these activities must be familiar with the relevant national
standards and regulations for electrical engineering.
Additional knowledge is required for any activity in hazardous areas!
R. STAHL recommends having a level of knowledge equal to that described in the
following standards:
UL 60079-17 (Electrical Installations Inspection and Maintenance)
National Electrical Code (NEC NFPA 70 Article 504 or ISA-RP 12.6)
Canadian Electrical Code, Part I, Safety Standard for Electrical Installations
(CSA C22.1)
Local regulations and laws
Symbol Meaning
FM test mark, proven conformity of the product with the safety regulations of
the USA and Canada
16338E00
Notified body for quality control.
02198E00
Device certified for hazardous areas according to the marking.
Safety Notes
6294417 / 8571665300
2022-07-28·IO00·III·en·00
DE
US
FR
IT
ES
RU
NL
DK
SE
FI
PT
GR
PL
CZ
SK
HU
SL
RO
BG
LV
LT
EE
CH
KR
CN
SolConeX
Flange socket, 30 A
8571/25 series
3.3 Safe Use
Before mounting
Read and observe the safety notes in these operating instructions!
Ensure that the contents of these operating instructions are fully understood by the
personnel in charge.
Use the device in accordance with its intended and approved purpose only.
Always consult R. STAHL Schaltgeräte GmbH if using the device under operating
conditions which are not covered by the technical data.
Make sure that the device is not damaged.
We cannot be held liable for damage to the device caused by incorrect or
impermissible use or non-compliance with these operating instructions.
For mounting and installation
Have mounting and installation performed only by qualified and authorised persons
(see chapter "Personnel qualification").
The device is only to be installed in areas for which it is suited based on its marking.
During installation and operation, observe the information (characteristic values and
rated operating conditions) on the rating and data plates, as well as the technical data
in these operating instructions and the information plates on the device.
Before installation, make sure that the device is not damaged.
The device must be installed into an enclosure compliant with the requirements of a
known type of protection according to UL 60079-0.
Do not open the device when it is energized.
Prevent electrostatic discharge at the device.
During assembly, use the prescribed creepage distances and clearances
(acc. to UL 60079-7, UL 60947-4, UL 60947-1).
Commissioning, maintenance, repair
Only have commissioning and repairs performed by qualified and authorised persons
(see chapter "Personnel qualification").
Before commissioning, make sure that the device is not damaged.
Perform only maintenance work described in these operating instructions.
The nature of these instructions is only informative and does not cover all of
the details, variations or combinations in which this equipment may be used,
its storage, delivery, installation, safe operation and maintenance.
Since conditions of use of the product are outside of the care, custody and
control of the manufacturer, the purchaser should determine the suitability of
the product for his intended use, and assumes all risk and liability whatsoever
in connection therewith.
294417 / 8571665300
2022-07-28·IO00·III·en·00
Safety Notes
7
DE
US
FR
IT
ES
RU
NL
DK
SE
FI
PT
GR
PL
CZ
SK
HU
SL
RO
BG
LV
LT
EE
CH
KR
CN
SolConeX
Flange socket, 30 A
8571/25 series
3.4 Specific Conditions of Use
For Class I, Zone 1 applications, the flange socket must be installed in an enclosure
with "eb" increased safety.
For Class I, Zone 1 applications, the flange socket must be installed in an enclosure
such that the creepage distances and clearances comply with the "eb" increased
safety spacing requirements of UL 60079-7.
For Zone 21 applications, the flange socket must be installed in a dust protected "tb"
enclosure.
For Class I, Division 2 applications, the flange socket must be installed in an enclosure
that complies with the ingress requirements for the specific application.
For Class I, Division 2 applications, the flange socket must be installed in the enclosure
such that the creepage and clearance comply with the requirements of specific
application.
For Class II, Division 1 applications, the flange socket must be installed in a
dust-ignition proof enclosure.
For Class II, Division 1 applications, the flange socket must be installed in the
enclosure such that the creepage distances and clearances comply with the
requirements of specific application.
Lock the hinged cover using the bayonet ring if the plug is not inserted.
The flange socket is suitable for connection to a 8571/22 plug of the same
configuration and electrical ratings.
3.5 Modifications and Alterations
DANGER
Explosion hazard due to modifications and alterations to the device!
Non-compliance results in severe or fatal injuries.
Do not modify or change the device.
No liability or warranty for damage resulting from modifications and
alterations.
Function and Device Design
8294417 / 8571665300
2022-07-28·IO00·III·en·00
DE
US
FR
IT
ES
RU
NL
DK
SE
FI
PT
GR
PL
CZ
SK
HU
SL
RO
BG
LV
LT
EE
CH
KR
CN
SolConeX
Flange socket, 30 A
8571/25 series
4 Function and Device Design
4.1 Function
Application range
The 8571/25 flange socket is incomplete equipment.
Depending on the area of application, it must be installed in an enclosure specially
intended for that purpose (see chapter 3.4).
5 Technical Data
Please refer to the technical data on the device.
DANGER
Explosion hazard due to improper use!
Non-compliance results in severe or fatal injuries.
Use the device only according to the operating conditions
described in these operating instructions.
Use the device only for the intended purpose specified in these
operating instructions.
Explosion protection
Global (IECEx)
Gas and dust IECEx PTB 20.0004U
Ex db eb IIC Gb
Ex tb IIIC Db
Europe (ATEX)
Gas and dust PTB 20 ATEX 1004 U
EII 2 G Ex db eb IIC Gb
EII 2 D Ex tb IIIC Db
USA (NEC)
Gas and dust
FM21US0072U
Cl. I, Zone 1, AEx db eb IIC Gb
Cl. I, Div. 2, Groups A, B, C, D
Zone 21, AEx tb IIIC Db
Cl. II, III. Div. 1, Groups E, F, G
Canada (CE Code)
Gas and dust FM21CA0047U
Ex db eb IIC Gb
Cl. I, Div. 2, Groups A, B, C, D
Ex tb IIIC Db
Cl. II, III. Div. 1, Groups E, F, G
294417 / 8571665300
2022-07-28·IO00·III·en·00
Technical Data
9
DE
US
FR
IT
ES
RU
NL
DK
SE
FI
PT
GR
PL
CZ
SK
HU
SL
RO
BG
LV
LT
EE
CH
KR
CN
SolConeX
Flange socket, 30 A
8571/25 series
Technical data
Electrical data
Rated operational
voltage
Main contacts max. 600 V AC/max. 110 V DC
Auxiliary contacts max. 500 V AC/max. 110 V DC
Frequency 50/60 Hz (for frequencies 100 Hz reduction to 25 A required)
Voltage tolerance -10 to +10 %
Rated operational
current
Main contacts 30 A
Auxiliary contacts max. 6 A
Utilisation category AC-3: 600 V/32 A
DC-1: 110 V/32 A
UL508: 600 V/30 A
Rated insulation
voltage
Main contacts 750 V
Auxiliary contacts 550 V
Back-up fuse
without thermal
protection
35 A gG
with thermal
protection
63 A gG
Alternatively, a Class J fuse of suitable size can be used.
Technical Data
10 294417 / 8571665300
2022-07-28·IO00·III·en·00
DE
US
FR
IT
ES
RU
NL
DK
SE
FI
PT
GR
PL
CZ
SK
HU
SL
RO
BG
LV
LT
EE
CH
KR
CN
SolConeX
Flange socket, 30 A
8571/25 series
Ambient conditions
Service temperature -50 to +65 °C/-58 to 149 °F
-40 to +65 °C/-40 to 149 °F, optional (silicone-free)
(The storage temperature corresponds to the ambient temperature)
At frequencies < 100 Hz
3 pole / 4 wire (3P + PE) - with auxiliary contacts
Temperature
class
T6
Ambient
temperature
Ta
+25
°C/
+77
°F
Ta
+30
°C/
+86
°F
Ta
+35
°C/
+95
°F
Ta
+40
°C/
+104
°F
Ta
+45
°C/
+113
°F
Ta
+50
°C/
+122
°F
Ta
+55
°C/
+131
°F
Ta
+60
°C/
+140
°F
Ta
+65
°C/
+149
°F
Connection
cross-section
Rated operational current
Socket Plug
4
mm2/
AWG 12
4
mm2/
AWG 12
32 A 32 A 27.5 A 27.5 A 27.5 A 25 A 20 A 20 A
6
mm2/
AWG 10
4
mm2/
AWG 12
32 A 32 A 32 A 27.5 A 27.5 A 27.5 A 25 A 20 A
6
mm2/
AWG 10
6
mm2/
AWG 10
32 A 32 A 32 A 32 A 27.5 A 27.5 A 25 A 20 A 16 A
10
mm2/
AWG 8
6
mm2/
AWG 10
32 A 32 A 32 A 32 A 32 A 27.5 A 27.5 A 25 A 16 A
3 pole / 4 wire (3P + PE) - with auxiliary contacts
Temperature
class
T5
Ambient
temperature
Ta
+45
°C/
+113
°F
Ta
+50
°C/
+122
°F
Ta
+55
°C/
+131
°F
Ta
+60
°C/
+140
°F
Ta
+65
°C/
+149
°F
Connection
cross-section
Rated operational current
Socket Plug
4
mm2/
AWG 12
4
mm2/
AWG 12
32 A 27.5 A 25 A 20 A 16 A
6
mm2/
AWG 10
4
mm2/
AWG 12
32 A 32 A 27.5 A 20 A 16 A
6
mm2/
AWG 10
6
mm2/
AWG 10
32 A 32 A 27.5 A 25 A 16 A
10
mm2/
AWG 8
6
mm2/
AWG 10
32 A 32 A 27.5 A 27.5 A 20 A
Technical data
294417 / 8571665300
2022-07-28·IO00·III·en·00
Technical Data
11
DE
US
FR
IT
ES
RU
NL
DK
SE
FI
PT
GR
PL
CZ
SK
HU
SL
RO
BG
LV
LT
EE
CH
KR
CN
SolConeX
Flange socket, 30 A
8571/25 series
3 pole / 4 wire (3P + PE) - without auxiliary contacts
Temperature
class
T6
Ambient
temperature
Ta
+25
°C/
+77
°F
Ta
+30
°C/
+86
°F
Ta
+35
°C/
+95
°F
Ta
+40
°C/
+104
°F
Ta
+45
°C/
+113
°F
Ta
+50
°C/
+122
°F
Ta
+55
°C/
+131
°F
Ta
+60
°C/
+140
°F
Ta
+65
°C/
+149
°F
Connection
cross-section
Rated operational current
Socket Plug
4
mm2/
AWG 12
4
mm2/
AWG 12
32 A 32 A 27.5 A 27.5 A 27.5 A 25 A 20 A 20 A 16 A
6
mm2/
AWG 10
4
mm2/
AWG 12
32 A 32 A 32 A 27.5 A 27.5 A 27.5 A 25 A 20 A 16 A
6
mm2/
AWG 10
6
mm2/
AWG 10
32 A 32 A 32 A 32 A 32 A 27.5 A 27.5 A 25 A 16 A
10
mm2/
AWG 8
6
mm2/
AWG 10
32 A 32 A 32 A 32 A 32 A 27.5 A 27.5 A 25 A 20 A
3 pole / 4 wire (3P + PE) - without auxiliary contacts
Temperature
class
T5
Ambient
temperature
Ta
+45
°C/
+113
°F
Ta
+50
°C/
+122
°F
Ta
+55
°C/
+131
°F
Ta
+60
°C/
+140
°F
Ta
+65
°C/
+149
°F
Connection
cross-section
Rated operational current
Socket Plug
4
mm2/
AWG 12
4
mm2/
AWG 12
32 A 27.5 A 27.5 A 20 A 16 A
6
mm2/
AWG 10
4
mm2/
AWG 12
32 A 32 A 27.5 A 20 A 16 A
6
mm2/
AWG 10
6
mm2/
AWG 10
32 A 32 A 27.5 A 25 A 16 A
10
mm2/
AWG 8
6
mm2/
AWG 10
32 A 32 A 32 A 27.5 A 20 A
Technical data
Technical Data
12 294417 / 8571665300
2022-07-28·IO00·III·en·00
DE
US
FR
IT
ES
RU
NL
DK
SE
FI
PT
GR
PL
CZ
SK
HU
SL
RO
BG
LV
LT
EE
CH
KR
CN
SolConeX
Flange socket, 30 A
8571/25 series
4 pole / 5 wire (3P + N + PE) - with auxiliary contacts
Temperature
class
T6
Ambient
temperature
Ta
+25
°C/
+77
°F
Ta
+30
°C/
+86
°F
Ta
+35
°C/
+95
°F
Ta
+40
°C/
+104
°F
Ta
+45
°C/
+113
°F
Ta
+50
°C/
+122
°F
Ta
+55
°C/
+131
°F
Ta
+60
°C/
+140
°F
Ta
+65
°C/
+149
°F
Connection
cross-section
Rated operational current
Socket Plug
4
mm2/
AWG 12
4
mm2/
AWG 12
32 A 27.5 A 27.5 A 27.5 A 25 A 20 A 20 A 16 A
6
mm2/
AWG 10
4
mm2/
AWG 12
32 A 32 A 32 A 27.5 A 27.5 A 25 A 20 A 20 A
6
mm2/
AWG 10
6
mm2/
AWG 10
32 A 32 A 32 A 27.5 A 27.5 A 27.5 A 25 A 20 A
10
mm2/
AWG 8
6
mm2/
AWG 10
32 A 32 A 32 A 32 A 27.5 A 27.5 A 27.5 A 20 A 16 A
4 pole / 5 wire (3P + N + PE) - with auxiliary contacts
Temperature
class
T5
Ambient
temperature
Ta
+40
°C/
+104
°F
Ta
+45
°C/
+113
°F
Ta
+50
°C/
+122
°F
Ta
+55
°C/
+131
°F
Ta
+60
°C/
+140
°F
Ta
+65
°C/
+149
°F
Connection
cross-section
Rated operational current
Socket Plug
4
mm2/
AWG 12
4
mm2/
AWG 12
32 A 27.5 A 27.5 A 25 A 20 A
6
mm2/
AWG 10
4
mm2/
AWG 12
32 A 32 A 32 A 27.5 A 20 A
6
mm2/
AWG 10
6
mm2/
AWG 10
32 A 32 A 32 A 27.5 A 20 A
10
mm2/
AWG 8
6
mm2/
AWG 10
32 A 32 A 32 A 27.5 A 25 A 16 A
Technical data
294417 / 8571665300
2022-07-28·IO00·III·en·00
Technical Data
13
DE
US
FR
IT
ES
RU
NL
DK
SE
FI
PT
GR
PL
CZ
SK
HU
SL
RO
BG
LV
LT
EE
CH
KR
CN
SolConeX
Flange socket, 30 A
8571/25 series
4 pole / 5 wire (3P + N + PE) - without auxiliary contacts
Temperature
class
T6
Ambient
temperature
Ta
+25
°C/
+77
°F
Ta
+30
°C/
+86
°F
Ta
+35
°C/
+95
°F
Ta
+40
°C/
+104
°F
Ta
+45
°C/
+113
°F
Ta
+50
°C/
+122
°F
Ta
+55
°C/
+131
°F
Ta
+60
°C/
+140
°F
Ta
+65
°C/
+149
°F
Connection
cross-section
Rated operational current
Socket Plug
4
mm2/
AWG 12
4
mm2/
AWG 12
32 A 27.5 A 27.5 A 27.5 A 25 A 25 A 20 A 20 A 16 A
6
mm2/
AWG 10
4
mm2/
AWG 12
32 A 32 A 32 A 27.5 A 27.5 A 25 A 20 A 20 A 16 A
6
mm2/
AWG 10
6
mm2/
AWG 10
32 A 32 A 32 A 32 A 27.5 A 27.5 A 25 A 20 A 16 A
10
mm2/
AWG 8
6
mm2/
AWG 10
32 A 32 A 32 A 32 A 32 A 27.5 A 27.5 A 25 A 20 A
4 pole / 5 wire (3P + N + PE) - without auxiliary contacts
Temperature
class
T5
Ambient
temperature
Ta
+40
°C/
+104
°F
Ta
+45
°C/
+113
°F
Ta
+50
°C/
+122
°F
Ta
+55
°C/
+131
°F
Ta
+60
°C/
+140
°F
Ta
+65
°C/
+149
°F
Connection
cross-section
Rated operational current
Socket Plug
4
mm2/
AWG 12
4
mm2/
AWG 12
32 A 27.5 A 27.5 A 25 A 20 A 16 A
6
mm2/
AWG 10
4
mm2/
AWG 12
32 A 32 A 32 A 27.5 A 20 A 16 A
6
mm2/
AWG 10
6
mm2/
AWG 10
32 A 32 A 32 A 27.5 A 20 A 16 A
10
mm2/
AWG 8
6
mm2/
AWG 10
32 A 32 A 32 A 32 A 25 A 20 A
The maximum rated operational current depends on the conductor
cross-section and the ambient temperature.
For frequencies 100 Hz, reduction to 25 A required.
Technical data
Technical Data
14 294417 / 8571665300
2022-07-28·IO00·III·en·00
DE
US
FR
IT
ES
RU
NL
DK
SE
FI
PT
GR
PL
CZ
SK
HU
SL
RO
BG
LV
LT
EE
CH
KR
CN
SolConeX
Flange socket, 30 A
8571/25 series
Mechanical data
Number of poles 3 pole / 4 wire (3P + PE)
4 pole / 5 wire (3P + N + PE) (N-conductor connected)
Auxiliary contacts Optional max. 2 auxiliary contacts (ON – delayed, OFF – leading)
Auxiliary contacts in Ex i version are fitted with gold-plated contacts.
Optionally in NAMUR resistor circuitry.
Switching handle lockable in 0 or I position
Max. bracket
diameter
5 mm/0.19 inch
Enclosure material Polyamide, glass fibre reinforced
Degree of protection IP66 acc. to IEC 60529,
IP64 acc. to UL 60079,
Plug-side: NEMA 3, 4, 4X acc. to ANSI/NEMA 250
Impact strength IK 10 acc. to IEC/EN 62262-0,
7 joules acc. to UL 60079
Connection type Screw terminals
Connection terminals
Main contacts Solid 1 x 2.5 mm2 to 2 x 10 mm2
(1 x AWG 14 to 2 x AWG 8)
Finely stranded 1 x 2.5 mm2 to 2 x 6 mm2
(1 x AWG 14 to 2 x AWG 10)
Finely stranded with core end
sleeve
1 x 2.5 mm2 to 2 x 6 mm2
(1 x AWG 14 to 2 x AWG 10)
Solid/finely stranded 1 x 0.5 mm2 to 2 x 2.5 mm2
(1 x AWG 20 to 2 x AWG 14)
Weight 8571/25-4.. 1.3 kg/2.87 lbs
8571/25-5.. 1.5 kg/3.31 lbs
Service life > 2000 switching cycles (electric and mechanical) acc. to UL 60309-1
Tightening torque Terminals: 1.6 Nm/14.16 lbf inch
(for connection 2 x 10 mm2 /2 x AWG 8: 2.0 Nm/17.70 lbf inch)
Mounting screw for the flange socket: 2.3 Nm/20.35 lbf inch
Technical data
294417 / 8571665300
2022-07-28·IO00·III·en·00
Technical Data
15
DE
US
FR
IT
ES
RU
NL
DK
SE
FI
PT
GR
PL
CZ
SK
HU
SL
RO
BG
LV
LT
EE
CH
KR
CN
SolConeX
Flange socket, 30 A
8571/25 series
Arrangement of the earth contact sleeve
Position of time position
Example: 6 h position
22092E00
Arrangement of socket contacts and terminal markings
Arrangement of socket contacts and terminal markings in the 6h position
(View from the front side of the socket to the socket contacts)
3 pole / 4 wire
(3P + PE)
06556E00
4 pole / 5 wire
(3P + N + PE)
06555E00
8571/25-4.. 8571/25-5..
L1 L3
L2
L2 L3
L1 N
Transport and Storage
16 294417 / 8571665300
2022-07-28·IO00·III·en·00
DE
US
FR
IT
ES
RU
NL
DK
SE
FI
PT
GR
PL
CZ
SK
HU
SL
RO
BG
LV
LT
EE
CH
KR
CN
SolConeX
Flange socket, 30 A
8571/25 series
Colour code and arrangement of socket contacts and terminal markings;
HP rating assignment
Colour code according to UL 60309-1 and arrangement relative to the polarising slot for different voltages
and frequencies in accordance with UL 60309-2
1) Mainly for ship installations
For further technical data, see r-stahl.com.
6 Transport and Storage
Transport and store the device only in the original packaging.
Store the device in a dry place (no condensation) free of vibrations.
Do not drop the device.
No. of poles Frequency
[Hz]
Voltage
[V]
Colour
code
Position of
earth contact
sleeve
Current
[A]
Power
[HP]
3 pole /
4 wire
(3P + PE)
50 and 60 200 to 250 Blue 9h 16 to 30 10
50 and 60 380 to 415 Red 6h 16 to 30 15
50 and 60 480 Red 7h 16 to 30 20
50 and 60 600 to 690 Black 5h 16 to 30 25
60 440 to 460 1) Red 11h 16 to 30 20
100 to 300 > 50 Green 10h 16 to 25 3 to 20
4 pole /
5 wire
(3P + N + PE)
50 and 60 57/100 to 75/130 Yellow 4h 16 to 30 3
50 and 60 120/208 to 144/250 Blue 9h 16 to 30 10
50 and 60 200/346 to 240/415 Red 6h 16 to 30 15
50 and 60 277/480 Red 7h 16 to 30 20
50 and 60 347/600 to 400/690 Black 5h 16 to 30 25
50 230/400 Red 3h 16 to 30 15
60 250/440 to 265/460 1) Red 11h 16 to 30 20
100 to 300 > 50 Green 10h 16 to 25 3 to 20
> 300 to 500 > 50 Green 2h 16 to 25 3 to 20
294417 / 8571665300
2022-07-28·IO00·III·en·00
Mounting and Installation
17
DE
US
FR
IT
ES
RU
NL
DK
SE
FI
PT
GR
PL
CZ
SK
HU
SL
RO
BG
LV
LT
EE
CH
KR
CN
SolConeX
Flange socket, 30 A
8571/25 series
7 Mounting and Installation
7.1 Dimensions/Fastening Dimensions
Dimensional drawings (all dimensions in mm [inch]) – Subject to change
03212E00
03348E00
8571/25-4.. and 8571/25-5..
SolConeX flange socket
Opening figure
Type Versions A B
8571/25-... 405, 406, 407 approx. 234 [9.21] approx. 90 [3.54]
409, 410, 411 approx. 218 [8.58] approx. 74 [2.91]
502, 503, 504 approx. 223 [8.78] approx. 79 [3.11]
505, 506, 507 approx. 234 [9.21] approx. 90 [3.54]
509, 510, 511 approx. 222 [8.74] approx. 78 [3.07]
0
I
107 [4,21]
B
~[~]144 5,67
A
~ 151 [~ 5,9 ]4
ø 4,50 ±0,10
[ø 0,18 ]±0,004
[1,54 ]
±0,01
39 ±0,20
ø 97 [ø 3,82 ]
±0, 02 ± 0,01
99 [3,90 ]
±0, 02 ± 0,01
88 [3,46 ]±0, 02 ± 0,01
94 [3,70 ]±0, 02 ± 0,01
46
±0, 02
[1,81 ]
±0,01
Mounting and Installation
18 294417 / 8571665300
2022-07-28·IO00·III·en·00
DE
US
FR
IT
ES
RU
NL
DK
SE
FI
PT
GR
PL
CZ
SK
HU
SL
RO
BG
LV
LT
EE
CH
KR
CN
SolConeX
Flange socket, 30 A
8571/25 series
7.2 Mounting/Dismounting, Operating Position
7.2.1 Mounting
The connected 8571/25 flange socket is intended to be mounted on an Ex e enclosure
(metal or plastic). Therefore, the following installation requirements have to be met:
Required fastening dimensions
See chapter 7.1.
Wall thickness of the enclosure
Metal enclosure: 1.5 to 3.0 mm/0.059 to 0.118 inch
Plastic enclosure: 2.2 to 3.5 mm/0.087 to 0.138 inch
Maximum surface roughness of the enclosure face for the seal
Metal enclosure: Rq = approx. 0.43 µm/Ra = approx. 0.38 µm
Plastic enclosure: Rz = approx. 7.2 μm
Mounting auxiliary contacts
This device is suitable for outdoor and indoor use.
The seal of the device ensures the IP degree of protection.
For mounting instructions for installing the auxiliary contacts, see installation
note 8570/8571 (8570607300).
11203E00
Open the enclosure.
Snap the auxiliary
contacts into place
optionally in the left-hand
or right-hand seat.
Double equipping is
possible.
Close the enclosure
294417 / 8571665300
2022-07-28·IO00·III·en·00
Mounting and Installation
19
DE
US
FR
IT
ES
RU
NL
DK
SE
FI
PT
GR
PL
CZ
SK
HU
SL
RO
BG
LV
LT
EE
CH
KR
CN
SolConeX
Flange socket, 30 A
8571/25 series
7.3 Installation
DANGER
Explosion hazard due to insufficient protective measures!
Non-compliance results in severe or fatal injuries.
Select suitable conductors to ensure that the maximum
permissible conductor temperatures are not exceeded.
Lay cables in intrinsically safe circuit separately to cables in
non-intrinsically-safe circuits. The distance measurements for
this can be found in the "Separating intrinsically safe circuits
from non-intrinsically-safe circuits" section.
When using core end sleeves, attach them using a suitable tool.
Use only separately tested cable entries and stopping plugs
with a US type examination certificate.
The conductor insulation must be touching the terminal.
Do not damage the conductor (e.g. nicking)
when stripping it.
Always connect the protective conductor.
DANGER
Explosion hazard in the case of installation in special dust hazardous
areas!
Non-compliance results in severe or fatal injuries.
Do not use the device in areas where there are processes
generating strong charges, machine friction processes,
separation processes and electrospray processes
(e.g. around electrostatic coating systems)
and pneumatically generated dust.
DANGER
Explosion hazard if seal is insufficient and/or service temperature
is too high!
Non-compliance results in severe or fatal injuries.
Completely seal the bayonet ring of the plug and of the hinged
cover to obtain the degree of protection.
Securely seal and lock the enclosure.
Make sure the service temperature range is maintained
(see the "Technical data" chapter).
Mounting and Installation
20 294417 / 8571665300
2022-07-28·IO00·III·en·00
DE
US
FR
IT
ES
RU
NL
DK
SE
FI
PT
GR
PL
CZ
SK
HU
SL
RO
BG
LV
LT
EE
CH
KR
CN
SolConeX
Flange socket, 30 A
8571/25 series
Separating "intrinsically safe circuits" from "non-intrinsically-safe circuits"
Two conductors can be installed under one connection terminal.
The conductor material and conductor cross-section of both conductors must
be identical.
The conductors can be connected without any special prior measures.
6 mm/0.24 inch for a peak nominal voltage 375 V
8 mm/0.31 inch for a peak nominal voltage 750 V
or with earthed shielding in accordance with UL 913 or UL 60079-11,
UL 60079-25 (sufficient current load capacity)
20631E00
Open the enclosure.
Strip the conductors.
Insert the conductors into
the corresponding terminals
and clamp them
(for the tightening torque,
see the "Technical data" chapter).
Insert the stripped conductor ends
completely under the terminal.
Check if the conductors have
been clamped properly.
Align the conductors. Make sure
that the clamping units are not
under tension.
Close the enclosure
(for the tightening torque,
see the "Technical data" chapter).
B [mm/inch]
Main contacts 12/0.47
Auxiliary contacts 6/0.24
B
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47

Stahl 8571 Mode d'emploi

Taper
Mode d'emploi