Jenn-Air JGCP430WP Guide d'installation

Catégorie
Cuisinières
Taper
Guide d'installation

Ce manuel convient également à

INSTALLATION INSTRUCTIONS
CommerCial-Style GaS CooktopS
30" (76.2 Cm), 36" (91.4 Cm), and 48" (121.9 Cm)
For residential use only
INSTRUCTIONS D’INSTALLATION
tableS de CuiSSon à Gaz de type CommerCial
30" (76,2 Cm), 36" (91,4 Cm) et 48" (121,9 Cm)
Pour utilisation résidentielle uniquement
Table of Contents/Table des matières
W10899358A
IMPORTANT:
Installer:
Leave installation instructions with the homeowner.
Homeo
wner: Keep installation instructions for future reference.
IMPOR
TANT :
Installateur
: Remettre les instructions d'installation au propriétaire.
Pr
opriétaire : Conserver les instructions d'installation pour référence ultérieure
.
www.jennair.com (U.S.A.) www.jennair.ca (Canada)
COOKTOP SAFETY ........................................................................ 2
INSTALLATION REQUIREMENTS ................................................. 3
Tools and Parts .............................................................................3
Location Requirements ................................................................4
Electrical Requirements ...............................................................7
Gas Supply Requirements ...........................................................7
INSTALLATION INSTRUCTIONS ................................................... 8
Install Cooktop .............................................................................8
Install Optional Backguard ...........................................................8
Make Gas Connection .................................................................9
Install Griddle .............................................................................10
Complete Installation .................................................................10
GAS CONVERSIONS ....................................................................12
LP Gas Conversion ....................................................................12
Natural Gas Conversion .............................................................14
STRIP CIRCUITS ..........................................................................15
WIRING DIAGRAMS .....................................................................16
SÉCURITÉ DE LA TABLE DE CUISSON .....................................18
EXIGENCES D’INSTALLATION ...................................................19
Outillage et pièces ......................................................................19
Exigences d’emplacement .........................................................20
Spécifications électriques ..........................................................23
Spécifications de l’alimentation en gaz .....................................23
INSTRUCTIONS D’INSTALLATION .............................................24
Installation de la table de cuisson ..............................................24
Installation du dosseret facultatif ...............................................25
Raccordement au gaz ................................................................25
Installation de la plaque à frire ...................................................26
Achever l’installation ..................................................................26
CONVERSIONS POUR CHANGEMENT DE GAZ ......................29
Conversion pour l’alimentation au propane ..............................29
Conversion pour l’alimentation au gaz naturel ..........................32
SCHÉMA DES CIRCUITS ............................................................33
SCHÉMAS DE CÂBLAGE ............................................................34
2
COOKTOP SAFETY
WARNING: If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury or death.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or
the gas supplier.
WARNING: Gas leaks cannot always be detected by smell.
Gas suppliers recommend that you use a gas detector approved by UL or CSA.
For more information, contact your gas supplier.
If a gas leak is detected, follow the “What to do if you smell gas” instructions.
3
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Tools Needed
Adjustable wrench Tape measure Marker or pencil
Pipe wrench Flat-blade screwdriver
15
/
16
" combination wrench
Wrench or channel lock pliers Pipe-joint compound
resistant to LP gas
Noncorrosive leak-detection solution
For LP/Natural Gas Conversions
Adjustable wrench
3
/
8
" drive ratchet
1
/
2
" deep-well socket
7 mm nut driver Masking tape
IMPORTANT: Do not install a ventilation system that blows air downward toward this gas cooking appliance. This type of
ventilation system may cause ignition and combustion problems with this gas cooking appliance resulting in personal injury or
unintended operation.
In the State of Massachusetts, the following installation instructions apply:
Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
If using a ball valve, it shall be a T-handle type.
A flexible gas connector, when used, must not exceed 3 feet.
4
Parts Supplied
Check that all parts are included.
Gas pressure regulator
Burner grates
Burner bases and burner caps
Griddle drip tray (on griddle models)
Foam tape
LP orifice package (W10393255)
Conversion label (W10393342)
NOTE: The cooktop is manufactured for use with Natural gas.
To convert to LP gas, see the “Gas Conversions” section.
Optional Backguards
48" (121.9 cm) models and grill models must be installed with
a backsplash if installing at zero clearance to a combustible
backwall. See the “Cabinet Dimensions” section in the “Location
Requirements” section for installation requirements.
36" (91.4 cm) Retractable Backguard
Order Part Number 8284756
48" (121.9 cm) Retractable Backguard
Order Part Number 8284755
9" (22.9 cm) Backguard for 36" (91.4 cm) Cooktops
Order Part Number W10115776
9" (22.9 cm) Backguard for 48" (121.9 cm) Cooktops
Order Part Number W10115777
33
1
/
2
" (85.0 cm) Retractable Backguard with Wire Shelf
for 36" (91.4 cm) Cooktops
Order Part Number W10285448
33
1
/
2
" (85.0 cm) Retractable Backguard with Wire Shelf
for 48" (121.9 cm) Cooktops
Order Part Number W10285449
To order, see the “Assistance or Service” section of the Use
and Care Guide.
Check local codes and consult gas supplier. Check existing gas
supply and electrical supply. See the “Electrical Requirements”
and “Gas Supply Requirements” sections.
High Altitude Conversion
To convert the cooktop for elevations above 6,560 ft (1999.5 m),
order a High Altitude Conversion Kit.
Part Number W10394296 - LP high altitude
Part Number W10394295 - Natural gas high altitude
To order, see the “Assistance or Service” section of the Use and
Care Guide.
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Do not obstruct flow of combustion and ventilation air.
It is the installer’s responsibility to comply with installation
clearances specified on the model/serial/rating plate. The
model/serial/rating plate is located on the underside of the
cooktop burner base.
It is recommended that a 600 CFM or larger vent hood
be installed above the cooktop.
It is not recommended that a microwave hood combination
be mounted above the cooktop.
The cooktop should be installed in a location away from
strong draft areas, such as windows, doors, and strong
heating vents or fans.
All openings in the wall or floor where cooktop is to be
installed must be sealed.
Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.
Grounded electrical supply is required. See the “Electrical
Requirements” section.
Proper gas supply connection must be available. See the
“Gas Supply Requirements” section.
The cooktop is designed to hang from the countertop
by its side or rear flanges.
The gas and electric supply should be located as shown in
the “Gas and Electric Connection Locations” section so that
they are accessible without requiring removal of the cooktop.
Provide cutout in left rear corner of cutout enclosure as
shown to provide clearance for gas inlet, power supply cord,
and to allow the rating label to be visible.
IMPORTANT: To avoid damage to your cabinets, check with
your builder or cabinet supplier to make sure that the materials
used will not discolor, delaminate, or sustain other damage.
Mobile Home - Additional Installation Requirements
The installation of this cooktop must conform to the
Manufactured Home Construction and Safety Standard,
Title 24 CFR, Part 3280 (formerly the Federal Standard for
Mobile Home Construction and Safety, Title 24, HUD Part
280). When such standard is not applicable, use the Standard
for Manufactured Home Installations, ANSI A225.1/NFPA 501A
or local codes.
In Canada, the installation of this cooktop must conform with
the current standards CAN/CSA-A240-latest edition or with
local codes.
5
Product Dimensions
Side View of Cooktop
Gas and Electric Connection Locations
A
B
C
D
E
A. 27
1
/
8
” (68.9 cm)
B. 30" (76.2 cm) cooktop: 29
7
/
8
" (75.9 cm)
36" (91.4 cm) cooktop: 35
3
/
4
" (90.8 cm)
48" (121.9 cm) cooktop: 47
7
/
8
" (121.6 cm)
C. Island trim or optional backguard
D. 36" (91.4 cm) long 3 prong grounding-type
power supply cord
E. Model/serial/rating plate (located on the
underside of the cooktop burner base)
A
C
F
G
D
E
B
A. 27
3
/
4
" (70.5 cm)
B. 1
1
/
4
" (3.2 cm)
C. 7
7
/
16
" (18.8 cm)
D. Gas inlet is located 1
7
/
8
" (4.8 cm) from the back
of the cooktop burner base and 4
7
/
8
" (12.4 cm) in
from left-hand side of the cooktop burner base.
E. 22" (55.9 cm)
F. 3
5
/
16
" (8.4 cm)
G.
9
/
16
" (1.4 cm)
A
B
C
D
A. Grounded 3 prong outlet should be located on
left-hand side of the cutout 16" (40.6 cm) max.
from enclosure sidewall
B. 10" (25.4 cm) min. clearance from countertop to
top of the outlet
C. 14" (35.6 cm) countertop to the gas supply line
D. Gas supply line should be located in this area on
rear or side walls or the supply line can come up
through the floor.
NOTE: Solid side and bottom of cutout enclosure
not shown.
6
Cabinet Requirements
Size Model A*
Cooktop
Cutout to
Back Wall
B**
Cooktop to
Cabinet
C
Optional Backguard
and Upper Cabinet
Opening
D
Cabinet and
Countertop
E
Countertop Only
30" (76.2 cm)
JGCP430 1
3
/
4
" (4.4 cm)*
30" (76.2 cm) 30" (76.2 cm)
29
1
/
4
" (74.3 cm)
30" (76.2 cm) or
29
7
/
8
" (75.9 cm) for
zero clearance
36" (91.4 cm) JGCP436
JGCP536
1
3
/
4
" (4.4 cm)* 42" (106.7 cm) 36" (91.4 cm) 35
1
/
4
" (89.5 cm) 36" (91.4 cm) or
35
3
/
4
" (90.8 cm) for
zero clearance
48" (121.9 cm) JGCP548 1
3
/
4
" (4.4 cm)* 42" (106.7 cm) 48" (121.9 cm) 47
1
/
4
" (120.0 cm) 48" (121.9 cm) or
47
7
/
8
" (121.6 cm) for
zero clearance
* NOTE: If backwall is constructed of a combustible material and a backguard is not installed, a minimum clearance of
dimension A + 3" (7.6 cm) is required for 36" (91.4 cm) and 48" (121.9 cm) cooktops.
** NOTES: Dimension “B” can be reduced by 6" (15.2 cm) when bottom of wood or metal cabinet is covered by not less than
0.25" (6.4 mm) flame retardant millboard covered with not less than No. 28 MSG sheet metal, 0.015" (0.4 mm) stainless steel,
0.024" (0.6 mm) aluminum, or 0.020" (0.5 mm) copper.
If installing a range hood above the cooktop, follow the range hood instructions for dimensional clearances above the
cooktop surface.
B min.**
C
A*
D
E
F
I
J
K
M
G
N
O
H
C
E
L
P
L
D
A. See chart.
B. See chart.
C. See chart.
D. See chart.
E. See chart.
F. 18" (45.7 cm) min. clearance upper cabinet
to countertop
G.
3
/
4
" (1.9 cm) back of cabinet cutout to gas
opening cutout
H. 6
7
/
8
" (16.1 cm) gas opening cutout depth
I. 12
1
/
2
" (31.7 cm) gas opening cutout width
J. 22
1
/
4
" (56.5 cm) cabinet cutout depth
K. 2" (5.1 cm) cabinet side to gas cutout
L. 6" (15.2 cm) min. distance on both sides of the
cooktop to the side wall or other combustible
material above cooking surface
M. 24" (61.0 cm) cabinet depth
N. 7
1
/
4
" (18.4 cm) cabinet depth to countertop
O. Notch to be equal on both sides
P. 13" (33.0 cm) upper cabinet depth
7
Electrical Requirements
IMPORTANT: The cooktop must be electrically grounded in
accordance with local codes and ordinances, or in the absence
of local codes, with the National Electrical Code, ANSI/NFPA 70
or Canadian Electrical Code, CSA C22.1.
This cooktop is equipped with an electronic ignition system
that will not operate if plugged into an outlet that is not
properly polarized.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine
that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
A 120-volt, 60 Hz, AC-only, 15-amp, fused electrical circuit
is required. A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit
serving only this cooktop be provided.
Electronic ignition systems operate within wide voltage limits,
but proper grounding and polarity are necessary. Check that
the outlet provides 120-volt power and is correctly grounded.
The wiring diagrams are provided with this cooktop. The
wiring diagrams are located inside the control console and
in the “Wiring Diagrams” section.
Gas Supply Requirements
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes
and ordinances. In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest
edition.
IMPORTANT: Leak testing of the cooktop must be conducted
according to the manufacturer’s instructions.
Type of Gas
Natural Gas:
This cooktop is factory-set for use with Natural gas. To
convert to LP gas, see the Gas Conversion instructions
provided in the package containing literature. The model/
serial/rating plate located on the left underside of the
cooktop burner base has information on the types of gas
that can be used. If the types of gas listed do not include
the type of gas available, check with the local gas supplier.
LP Gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the cooktop from the gas
specified on the model/serial/rating plate for use with a different
gas without consulting the serving gas supplier. To convert to LP
gas, use the LP gas conversion kit provided with the cooktop
and see the “Gas Conversions” section.
Gas Supply Line
Provide a gas supply line of
3
/
4
" (1.9 cm) rigid pipe to the
cooktop location. A smaller size pipe on longer runs may
result in insufficient gas supply. With LP gas, piping or tubing
size can be
1
/
2
" (1.3 cm) minimum. Usually, LP gas suppliers
determine the size and materials used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas
must be used. Do not use TEFLON
®†
tape.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
®
TEFLON is a registered trademark of Chemours.
8
Flexible metal appliance connector:
If local codes permit, a new CSA design-certified, 4 - 5 ft
(122 - 152.4 cm) long,
5
/
8
" (1.6 cm) or
3
/
4
" (1.9 cm) I.D.,
flexible metal appliance connector may be used for
connecting the cooktop to the gas supply line.
A
1
/
2
" (1.3 cm) male pipe thread is needed for connection
to the female pipe threads of the inlet to the appliance
pressure regulator.
Do not kink or damage the flexible metal tubing when
moving the cooktop.
Must include a shut-off valve:
The supply line must be equipped with a manual shut-off
valve. This valve should be located in the same room but
external to the cooktop enclosure or cabinet. It should be in
a location that allows ease of opening and closing. Do not
block access to shut-off valve. The valve is for turning on or
shutting off gas to the cooktop.
Gas Pressure Regulator
The gas pressure regulator supplied with this cooktop must
be used. The inlet pressure to the regulator should be as
follows for proper operation:
Natural Gas:
Minimum pressure: 6" (15.2 cm) WCP
Maximum pressure: 14" (35.5 cm) WCP
LP Gas:
Minimum pressure: 11" (27.9 cm) WCP
Maximum pressure: 14" (35.5 cm) WCP
Contact local gas supplier if you are not sure about the inlet
pressure.
Burner Input Rating - Altitude
Input ratings shown on the model/serial rating plate are for
elevations up to 2,000 ft (609.6 m).
For elevations above 2,000 ft (609.6 m), ratings need to be
reduced at a rate of 4% for each 1,000 ft (304.8 m) above
sea level (not applicable for Canada).
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least
1" water column pressure above the manifold pressure shown
on the model/serial/rating plate.
Line pressure testing above
1
/
2
psi gauge (14" WCP)
The cooktop and its individual shut-off valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
1
/
2
psi (3.5 kPa).
Line pressure testing at
1
/
2
psi gauge (14" WCP) or lower
The cooktop must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than
1
/
2
psi (3.5 kPa).
INSTALLATION INSTRUCTIONS
Install Cooktop
Write down the model and serial numbers before installing the
cooktop. Both numbers are located on the left front underside of
the burner base.
Unpack the parts supplied with your cooktop. The parts shipped
with the cooktop depend on your model ordered. See the “Tools
and Parts” section for a complete list of parts supplied with your
cooktop.
The pressure regulator and flexible stainless steel gas supply
line connector can be assembled to the cooktop now or after
the cooktop is installed in the cutout. See the “Make Gas
Connection” section.
1. Decide on the final location for the cooktop.
2. Using two or more people, place the cooktop upside down
on a covered surface.
3. Remove foam strip from literature packing. Remove backing
from foam strip. Apply foam strip adhesive-side down along
the left and right sides of the cooktop trim.
NOTE: The foam strip helps the cooktop sit flat on uneven
counters and avoids damage to the countertop surface.
4. Using 2 or more people, turn cooktop right side up.
Install Optional Backguard
36" (91.4 cm) and 48" (121.9 cm) models may require a
backguard. See “Cabinet Dimensions” in the “Location
Requirements” section for installation requirements. See
the “Tools and Parts” section for information on ordering.
Remove island trim and attach backguard using 6 screws;
insert 3 from the front and 3 from the back (9" [22.9 cm]
backguard shown).
A
B
C
A. Gas supply line
B. Shut-off valve “open” position
C. To cooktop
WARNING
Excessive Weight Hazard
Use two or more people to move and install cooktop.
Failure to do so can result in back or other injury.
A
B
C
A. Cooktop base
B. Foam strip
C. Cooktop
9
Make Gas Connection
To Assemble Pressure Regulator:
1. Using 2 or more people, stand the cooktop on its side
or back.
2. Connect the flexible stainless steel connector to the pressure
regulator using a
1
/
2
" male pipe thread adapter.
A combination of pipe fittings must be used to connect the
cooktop to the existing gas line. The following shows a
typical connection. Your connection may be different,
according to the supply line type, size, and location.
3. Install the pressure regulator with the arrow pointing up
toward the bottom of the cooktop burner base and in a
position where you can reach the regulator cap.
IMPORTANT: All connections must be wrench-tightened.
Do not make connections to the gas regulator too tight.
Making the connections too tight may crack the regulator
and cause a gas leak. Do not allow the regulator to turn on
the pipe when tightening fittings.
Use only pipe-joint compound made for use with Natural
and LP gas. Do not use TEFLON
®
tape.
You will need to determine the fittings required depending
on your installation.
4. Place cooktop into the countertop cutout.
NOTE: Check that the front edge of the cooktop is parallel
to the front edge of the countertop. If repositioning
is needed, lift entire cooktop up from cutout to avoid
scratching the countertop.
Typical flexible connection
1. Apply pipe-joint compound made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see
B and F in the following illustration).
2. Attach one adapter to the gas pressure regulator and
the other adapter to the gas shut-off valve. Tighten both
adapters.
3. Use a
15
/
16
" combination wrench and channel lock pliers to
attach the flexible connector to the adapters. Check that
connector is not kinked.
Complete Connection
1. Open the manual shut-off valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
2. Test all connections by brushing on an approved
noncorrosive leak-detection solution. If bubbles appear,
a leak is indicated. Correct any leak found.
3. Remove cooktop burner caps, burner bases, and grates
from parts package. Place burner bases on cooktop. Place
burner caps on burner bases. Place grates over burners and
caps.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A
B
D
C
A. Gas pressure regulator
B. Regulator - Must be installed with arrow pointing up
to cooktop bottom
C. Adapter - Must have
1
/
2
" male pipe thread
D. CSA Approved flexible stainless steel gas supply line
A
B
C
D
E
F
G
H
A. Gas pressure regulator
B. Use pipe-joint compound.
C. Adapter - must have
1
/
2
"
male pipe thread
D. Flexible connector
E. Adapter
F. Use pipe-joint compound.
G.
1
/
2
" or
3
/
4
" gas pipe
H. Manual gas shut-off valve
A
B
A. Closed valve
B. Open valve
10
4. Plug into a grounded 3 prong outlet.
5. Check the operation of the surface burners. See “Check
Operation of Cooktop Burners” in the “Complete Installation”
section.
6. If your model has a griddle, see the “Install Griddle” section.
Install Griddle
(on griddle models)
The griddle is factory installed.
1. Place drip tray in the well at the front of the griddle. Slide tray
toward the back until it stops.
2. Clean griddle before using. Refer to the Use and Care Guide.
Complete Installation
Install Burner Bases and Burner Caps
Install the burner base, making sure the igniter electrode is
properly aligned with the base. Place burner caps on top
of burner bases. If burner caps are not properly positioned,
surface burners will not light.
Ultra Power™ Dual-Flame Burner
Professional Burner
Simmer/Melt Burner
Electronic Ignition System
Initial lighting and gas flame adjustments
Cooktop burners use electronic igniters in place of standing
pilots. When the cooktop control knob is turned to any position,
the system creates a spark to light the burner. This sparking
continues until the flame is lit or the knob is turned to OFF.
Check Operation of Cooktop Burners
Push in and turn each control knob to the Lite position.
The surface burners and grill flames should light within
4 seconds. The first time a burner is lit, it may take longer
than 4 seconds to light because of air in the gas line.
After verifying the proper burner operation, turn the control
knobs to OFF.
If burners do not light properly:
Turn cooktop control knob to the Off position.
Check that the cooktop is plugged in and the circuit breaker
has not tripped or the fuse has not blown.
Check that the gas shut-off valves are set to the
open position.
Check that burner caps are properly positioned on
burner bases.
Repeat start-up. If a burner does not light at this point, contact
your dealer or authorized service company for assistance.
If you need Assistance or Service:
Please reference the “Assistance or Service” section of the Use
and Care Guide or contact the dealer from whom you purchased
your cooktop.
A
B
A. Griddle drip tray
B. Griddle
A. Incorrect
B. Correct
A
B
A. Incorrect
B. Correct
A
B
A. Incorrect
B. Correct
11
Flame Height
The cooktop flame should be a steady blue flame approximately
¼" (0.64 cm) high.
Dual Flame Burner
Single Flame Burner
To Adjust Flame Height:
1. Unplug cooktop or disconnect power.
2. Remove burner grates.
3. Remove the control knobs.
4. Pull cooktop forward to expose the control console screws
on the side of the cooktop burner base.
5. Remove the 2 screws on each side of the cooktop burner
base that hold the control console in place.
6. Disconnect wiring from the control console.
On Griddle Models:
Support the control console in the middle with one arm
and disconnect the griddle switch connectors and the
grill indicator light with the other hand.
7. Remove console and set aside.
8. Remove the round gasket from the valve stem.
9. Put a control knob onto the valve stem of the burner you
want to adjust.
10. Turn the control knob to LO and light the burner using a
butane extension lighter.
11. Remove the control knob.
12. Use a
1
/
8
" x 4
1
/
4
" flat-blade screwdriver to adjust the flame
height. Tighten screw to reduce flame height. Loosen screw
to increase flame height.
NOTE: When you are converting to LP gas, the screw should
be tightened down completely on the single output valves.
The dual output valve should not be adjusted.
13. When finished adjusting the flame height, put a control knob
back onto the valve stem and turn off the burner.
14. Remove the control knob.
15. Replace the round gasket.
16. Repeat steps 8 through 15 for any other burners that need
adjustment.
17. Reinstall the control console. Support the control console in
the middle with one arm and reconnect the griddle switch
connectors and/or grill indicator light connector.
18. Set the control console back into place on the cooktop. For
a proper fit, the flange of the control console must hook over
the lip on the front of the cooktop.
A
B
A. Upper (simmer) flame
B. Lower flame
A
A. Console attachment screws
A
B
A. Griddle switch connectors
B. Grill indicator light connector
A
B
A. Single flame burner adjustment screw (on right side of valve)
B. Dual flame burner adjustment screw (on left side of valve)
A
B
A. Control console flange
B. Front lip of range cooktop
12
19. Check that the control console is flush with the top edge of
the cooktop.
20. Replace the 2 screws on each side of the control console.
21. Push the cooktop back into place in the cutout.
22. Replace the control knobs.
23. Replace burner grates.
24. Plug in cooktop or reconnect power.
25. Test the flame by turning the control from LO to HI, checking
the flame at each setting.
GAS CONVERSIONS
IMPORTANT: Gas conversions from Natural gas to LP gas must
be done by a qualified installer.
LP Gas Conversion
1. Turn the manual shut-off valve to the closed position.
2. Unplug cooktop or disconnect power.
To Convert Gas Pressure Regulator
1. Remove the access cap by using a wrench, turning the
access cap counterclockwise.
2. Remove spring retainer from the cap by pushing against the
flat side of the spring retainer. Look at the spring retainer to
locate the “NAT” or “LP” position. Turn over the spring retainer
so the “LP” is showing on the bottom. Snap the spring
retainer back into the cap. Reinstall the cap onto the regulator.
3. Test the gas pressure regulator and gas supply line.
The regulator must be checked at a minimum 1" (2.5 cm)
water column above the set pressure. The inlet pressure
to the regulator should be as follows for operation and
checking the regulator setting:
LP Gas:
Minimum pressure 11" (27.9 cm) WCP
Maximum pressure 14" (35.5 cm) WCP
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least
1" water column pressure above the manifold pressure
shown on the model/serial/rating plate.
Line pressure testing above
1
/
2
psi gauge (14" WCP)
The cooktop and its individual shut-off valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of
1
/
2
psi (3.5 kPa).
Line pressure testing at
1
/
2
psi gauge (14" WCP) or lower
The cooktop must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than
1
/
2
psi (3.5 kPa).
To Convert Surface Burners
1. If installed, remove the burner grates.
2. Remove burner cap.
3. Remove the burner base.
A
B
Large Dual Burner
A. Burner cap
B. Burner base
A
B
C
Medium Burner
A. Burner cap
B. Burner base
C. Choke (for use with medium
burner, LP gas only)
A
B
Small Burner
A. Burner cap
B. Burner base
A
A. Flush with top of cooktop
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A
B
C
A. To cooktop
B. Shut-off valve (closed position)
C. Gas supply line
A
B
CDE
A. Access cap
B. Gasket
C. Gas pressure regulator
D. LP position
E. NAT position
13
4. Apply masking tape to the end of a 7 mm nut driver to help
hold the gas orifice spud in the nut driver while changing it.
Insert nut driver into gas opening and press down onto the
gas orifice spud, and remove by turning the gas orifice spud
counterclockwise and lifting out. Set gas orifice spud aside.
5. Replace with correct LP gas orifice spud. See the “LP Gas
Orifice Spud/Hood Chart.”
Burner orifice spud
Use the following chart to find the exact orifice spud
placement.
Fully insert choke into bottom of medium burner base.
Choke should snap into place. Refer to illustration to
verify that choke is fully seated.
NOTE: Chokes are placed on medium burners only.
LP Gas Orifice Spud/Hood Chart
Burner
Rating
Color Size Burner Style
3,000 BTUs Blue 0.55 mm Small burners
11,000 BTUs Yellow 0.97 mm Medium burners
14,000 BTUs Red/Green
Green
1.05 mm
0.35 mm
Large burner - main
Large burner - simmer
6. Place Natural gas orifice spuds in plastic parts bag for future
use and keep with package containing literature.
NOTE: There may be extra orifices in your kit.
7. Replace the burner base.
8. Replace burner cap.
9. Repeat steps 2 through 8 for the remaining burners.
10. Unplug cooktop or disconnect power.
11. Remove the control knobs.
12. Pull cooktop forward to expose the control console screws
on the side of the cooktop burner base.
13. Remove the 2 screws on each side of the cooktop burner
base that hold the control console in place.
14. Disconnect wiring from the control console.
On Griddle Models:
Support the control console in the middle with one arm and
disconnect the griddle switch connectors and the grill
indicator light with the other hand.
15. Remove console and set aside.
16. Remove the round gasket from the valve stem.
17. Use a
1
/
8
" x 4
1
/
4
" flat-blade screwdriver to completely screw
down all burner screws.
18. Replace the round gasket.
19. Reinstall the control console. Support the control console in
the middle with one arm and reconnect the griddle switch
connectors and/or grill indicator light connector.
A
A. Size stamp or color
Incorrectly seated choke
Correctly seated choke
A
B
C
Choke
A
A. Console attachment screws
A
B
A. Griddle switch connectors
B. Grill indicator light connector
A
B
A. Single flame burner adjustment screw (on right side of valve)
B. Dual flame burner adjustment screw (on left side of valve)
14
20. Set the control console back into place on the cooktop. For
a proper fit, the flange of the control console must hook over
the lip on the front of the cooktop.
21. Check that the control console is flush with the top edge of
the cooktop.
22. Replace the 2 screws on each side of the control console.
23. Push the cooktop back into place in the cutout.
24. Replace the control knobs.
25. Replace burner grates.
26. Plug in cooktop or reconnect power.
27. Test the flame by turning the control from LO to HI, checking
the flame at each setting.
Complete Installation
1. Refer to the “Make Gas Connection” section for properly
connecting the cooktop to the gas supply.
2. Refer to the “Electronic Ignition System” section for proper
burner ignition, operation, and burner flame adjustments.
IMPORTANT: You may have to adjust the LO setting for each
cooktop burner.
Checking for proper cooktop burner flame is very important.
The small inner cone should have a very distinct blue flame
1
/
4
" (0.64 cm) to
1
/
2
" (1.3 cm) long. The outer cone is not
as distinct as the inner cone. LP gas flames have a slightly
yellow tip.
3. Refer to “Complete Installation” in the “Installation
Instructions” section of this manual to complete this
procedure.
Natural Gas Conversion
1. Turn the manual shut-off valve to the closed position.
2. Unplug cooktop or disconnect power.
To Convert Gas Pressure Regulator
1. Remove the access cap by using a wrench, turning the
access cap counterclockwise.
2. Remove spring retainer from the cap by pushing against the
flat side of the spring retainer. Look at the spring retainer to
locate the “LP” or “NAT” position. Turn over the spring
retainer so the “NAT” is showing on the bottom. Snap the
spring retainer back into the cap. Reinstall the cap onto the
regulator.
3. Test the gas pressure regulator and gas supply line.
The regulator must be checked at a minimum 1" (2.5 cm)
water column above the set pressure. The inlet pressure
to the regulator should be as follows for operation and
checking the regulator setting:
LP Gas:
Minimum pressure 6" (15.2 cm) WCP
Maximum pressure 14" (35.5 cm) WCP
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least
1" water column pressure above the manifold pressure
shown on the model/serial/rating plate.
Line pressure testing above
1
/
2
psi gauge (14" WCP)
The cooktop and its individual shut-off valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of
1
/
2
psi (3.5 kPa).
Line pressure testing at
1
/
2
psi gauge (14" WCP) or lower
The cooktop must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than
1
/
2
psi (3.5 kPa).
A
B
A. Control console flange
B. Front lip of range cooktop
A
A. Flush with top of cooktop
A
B
C
A. To cooktop
B. Shut-off valve (closed position)
C. Gas supply line
A
B
CDE
A. Access cap
B. Gasket
C. Gas pressure regulator
D. NAT position
E. LP position
15
To Convert Surface Burners
1. If installed, remove the burner grates.
2. Remove burner cap.
3. Remove the burner base.
A
B
Large Dual Burner
A. Burner cap
B. Burner base
A
B
C
Medium Burner
A. Burner cap
B. Burner base
C. Choke (for use with medium
burner, LP gas only)
A
B
Small Burner
A. Burner cap
B. Burner base
4. Apply masking tape to the end of a 7 mm nut driver to help
hold the gas orifice spud in the nut driver while changing it.
Insert nut driver into gas opening and press down onto the
gas orifice spud and remove by turning the gas orifice spud
counterclockwise and lifting out. Set gas orifice spud aside.
5. Replace with correct Natural gas orifice spud. See the
“Natural Gas Orifice Spud/Hood Chart.”
Burner orifice spud
Use the following chart to find the exact orifice spud
placement.
Remove choke from medium burner base.
Natural Gas Orifice Spud/Hood Chart
Burner
Rating
Color Size Burner Style
5,000 BTUs NG 5k
Small
burner bag
0.97 mm Small burners
15,000 BTUs No color 1.75 mm Medium burners
20,000 BTUs Blue/Yellow
Black
1.98 mm
0.52 mm
Large burner - main
Large burner - simmer
6. Place LP gas orifice spuds in plastic parts bag for future use
and keep with package containing literature.
NOTE: There may be extra orifices in your kit.
7. Replace the burner base.
8. Replace burner cap.
9. Repeat steps 2 through 8 for the remaining burners.
Complete Installation
1. Refer to the “Make Gas Connection” section for properly
connecting the cooktop to the gas supply.
2. Refer to the “Electronic Ignition System” section for proper
burner ignition, operation, and burner flame adjustments.
IMPORTANT: You may have to adjust the LO setting for each
cooktop burner.
Checking for proper cooktop burner flame is very important.
The small inner cone should have a very distinct blue flame
1
/
4
" (0.64 cm) to
1
/
2
" (1.3 cm) long. The outer cone is not
as distinct as the inner cone. LP gas flames have a slightly
yellow tip.
3. Refer to “Complete Installation” in the “Installation
Instructions” section of this manual to complete this
procedure.
STRIP CIRCUITS
Griddle 120V Control Wiring Diagram to Cooktop Stand-Alone
A
A. Size stamp or color
R
W OR/W
OR/W OR/W
W
V
W
VVWW
P2-1
P2-6
P1-1
P1-3
P1-4
P1-6
Rotary Control
RTD
BU W
1320W/120V
Lamp 120V
16
WIRING DIAGRAMS
6-Burner Cooktop Reignition Wiring Diagram
Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
SW1
SW2
SW3
SW4
5
6
3
4
1
2
Power Cord Only To
Cooktop Stand-Alone
Version
GND
GN
Power
Cord
Griddle Spare
Grill Spare
Main - Harness
Power Spare
RD
WH
BK
WH
RD
Reignition
Module
Cooktop
Front View
GND
BK
WH
BK
WH
WH
BK
BK
RD
N
L
Control Input
Electrodes Output
Reignition
Module
RD
RD
RD
RD
RD
RD
BR
YL
GN
N
L
RD
OR
YL
GN
WH
BU
BU
LEGEND
Ground
(Chassis)
Plug With
Female
Connector
Receptacle
With Male
Connector
Electrode Tr ansformer Relay
Contacts
Solenoid
Valve
Switch Cooktop
Gas Burner
RTD -
Temperature
Sensor
Heating
Element
Indicator Lamp
17
4-Burner Cooktop Reignition Wiring Diagram
Power
Cord
LN
GND
GN
RD
RD
WH
WH
WH
WH
RD
BK
BK
BK
RD
RD
RD
RD
RD
RD
BU
BR
YL
GND
Control Input
Electrodes Output
SW1
SW2
SW3
SW4
L
N
YL
BR
BU
RD
2
1
4
3
Power Cord Only To
Cooktop Stand Alone
Version
Main - Harness
Power Spare
Griddle Spare
Grill Spare
Cooktop
Front View
LEGEND
Ground
(Chassis)
Plug With
Female
Connector
Receptacle
With Male
Connector
Electrode Tr ansformer Relay
Contacts
Solenoid
Valve
Switch Cooktop
Gas Burner
RTD -
Temperature
Sensor
Heating
Element
Indicator Lamp
18
SÉCURITÉ DE LA TABLE DE CUISSON
AVERTISSEMENT : Si les renseignements dans ce manuel ne sont pas exactement
observés, un incendie ou une explosion peut survenir, causant des dommages au
produit, des blessures ou un décès.
Ne pas entreposer ni utiliser de l’essence ou d’autres vapeurs ou liquides inflammables
à proximité de cet appareil ou de tout autre appareil électroménager.
QUE FAIRE DANS LE CAS D’UNE ODEUR DE GAZ :
Ne pas tenter d’allumer un appareil.
Ne pas toucher à un commutateur électrique.
Ne pas utiliser le téléphone se trouvant sur les lieux.
Appeler immédiatement le fournisseur de gaz à partir du téléphone d'un voisin. Suivre
ses instructions.
À défaut de joindre votre fournisseur de gaz, appeler les pompiers.
L’installation et l’entretien doivent être effectués par un installateur qualifié, une agence
de service ou le fournisseur de gaz.
AVERTISSEMENT : L’odorat ne permet pas toujours la détection d’une fuite de gaz.
Les distributeurs de gaz recommandent l’emploi d’un détecteur de gaz (homologation UL ou CSA).
Pour d’autre information, contacter le fournisseur de gaz local.
En cas de détection d’une fuite de gaz, exécuter les instructions “Que faire dans le cas d’une odeur de gaz”.
19
EXIGENCES D’INSTALLATION
Outillage et pièces
Rassembler les outils et composants nécessaires avant d’entreprendre l’installation. Lire et observer les instructions fournies avec
chacun des outils de la liste ci-dessous.
Outillage nécessaire
Clé à molette Mètre-ruban Marqueur ou crayon
Clé à tuyauterie Tournevis à lame plate Clé mixte de
15
/
16
"
Clé ou pince Composé d’étanchéité pour tuyauteries
– résistant au gaz propane
Solution non-corrosive
de détection des fuites
Pour conversions pour gaz propane/naturel
Clé à molette Clé à cliquet de
3
/
8
" Douille longue de
1
/
2
"
Tourne-écrou de 7 mm Ruban adhésif de masquage
IMPORTANT : Ne pas installer un système de ventilation avec évacuation de l'air vers le bas, qui évacuerait l'air vers cet
appareil de cuisson à gaz. Ce type de système de ventilation peut causer des problèmes d'allumage et de combustion avec cet
appareil de cuisson à gaz et entraîner des blessures corporelles ou le fonctionnement non désiré de cet appareil.
Dans l’État du Massachusetts, les instructions d’installation suivantes sont applicables :
Les travaux d’installation et réparation doivent être exécutés par un plombier ou tuyauteur qualifié ou licencié, ou par le
personnel qualifié d’une entreprise licenciée par l’État du Massachusetts.
Si une vanne à boisseau sphérique est utilisée, elle doit comporter une manette “T”.
Si un conduit de raccordement flexible est utilisé, sa longueur ne doit pas dépasser 3 pi.
20
Pièces fournies
Vérifier que toutes les pièces sont présentes.
Détendeur
Grilles de brûleur
Bases de brûleur et chapeaux de brûleur
Plateau d’égouttement de la plaque à frire (sur modèles avec
plaque à frire)
Ruban de mousse
Ensemble de gicleurs pour gaz propane (W10393255)
Étiquette de conversion (W10393342)
REMARQUE : La table de cuisson est conçue pour une
utilisation au gaz naturel. Pour effectuer une conversion
au gaz propane, voir la section “Conversions de gaz”.
Dosserets facultatifs
Les modèles de 48" (121,9 cm) et les modèles avec gril doivent
être installés avec un dosseret si l’installation se fait en contact
direct avec une paroi arrière combustible. Voir “Dimensions
du placard” à la section “Exigences d’emplacement” pour les
spécifications concernant l’installation.
Dosseret rétractable de 36" (91,4 cm)
Commander la pièce numéro 8284756
Dosseret rétractable de 48" (121,9 cm)
Commander la pièce numéro 8284755
Dosseret de 9" (22,9 cm) pour tables de cuisson de 36"
(91,4 cm)
Commander la pièce numéro W10115776
Dosseret de 9" (22,9 cm) pour tables de cuisson de 48"
(121,9 cm)
Commander la pièce numéro W10115777
Dosseret rétractable de 33
1
/
2
" (85,0 cm) avec clayette pour
tables de cuisson de 36" (91,4 cm)
Commander la pièce numéro W1028548
Dosseret rétractable de 33
1
/
2
" (85,0 cm) avec clayette pour
tables de cuisson de 48" (121,9 cm)
Commander la pièce numéro W10285449
Pour commander, voir la section “Assistance ou service” du
Guide d’utilisation et d’entretien.
Vérifier les codes locaux et consulter le fournisseur de gaz.
Vérifier l’alimentation en gaz et l’alimentation électrique
existantes. Voir les sections “Spécifications électriques”
et “Spécifications de l’alimentation en gaz”.
Conversion pour utilisation en haute altitude
Pour convertir la table de cuisson pour des altitudes supérieures
à 6 560 pi (1999,5 m), commander un ensemble pour conversion
en haute altitude.
Pièce numéro W10394296 - gaz propane pour haute altitude
Pièce numéro W10394295 - gaz naturel pour haute altitude
Pour commander, voir la section “Assistance ou service” du
Guide d’utilisation et d’entretien.
Exigences d’emplacement
IMPORTANT : Observer les dispositions de tous les codes et
règlements en vigueur. Ne pas obstruer le flux de combustion
et de ventilation.
C’est à l’installateur qu’incombe la responsabilité de
respecter les distances de séparation exigées pour
l’installation, spécifiées sur la plaque signalétique de
l’appareil. La plaque signalétique des numéros de modèle et
de série est située sur la face inférieure de la base de brûleur
de la table de cuisson.
Il est recommandé qu’une hotte de cuisinière de 600 CFM ou
plus soit installée au-dessus de la table de cuisson.
Il n’est pas recommandé de monter un ensemble hotte/four
à micro-ondes au-dessus de la table de cuisson.
La table de cuisson doit être installée dans un emplacement
à l’écart des zones de forts courants d’air, telles que
fenêtres, portes et évents ou ventilateurs de chauffage.
Toutes les ouvertures dans le mur ou le plancher de
l’emplacement d’installation de la table de cuisson doivent
être scellées.
Respecter les dimensions indiquées pour les ouvertures à
découper dans les placards. Ces dimensions constituent les
valeurs minimales des dégagements de séparation.
Une source d’électricité avec liaison à la terre est nécessaire.
Voir la section “Spécifications électriques”.
Une source de gaz adéquate doit être disponible. Voir la
section “Spécifications de l’alimentation en gaz”.
De par sa conception, la table de cuisson est suspendue sur
le plan de travail, par les rebords des côtés ou de l’arrière.
Les sources de gaz et d’électricité doivent être situées tel
qu’indiqué à la section “Emplacements des raccordements
au gaz et à l’électricité”, pour qu’elles soient accessibles et
qu’il ne soit pas nécessaire d’enlever la table de cuisson.
Prévoir une ouverture dans l’angle arrière gauche de
l’enceinte – voir l’illustration – pour le passage de la
canalisation de gaz et du câble d’alimentation électrique
et pour que l’étiquette signalétique soit visible.
IMPORTANT : Afin d’éviter d’endommager les placards,
consulter le constructeur de la maison ou le fabricant des
placards pour déterminer si les matériaux utilisés peuvent
subir un changement de couleur, une déstratification ou
d’autres dommages.
Résidence mobile – Spécifications additionnelles à
respecter lors de l’installation
L’installation de cette table de cuisson doit être conforme aux
dispositions de la norme Manufactured Home Construction
and Safety Standard, Title 24 CFR, Part 3280 (anciennement
Federal Standard for Mobile Home Construction and Safety,
Title 24, HUD Part 280). Lorsque cette norme n’est pas
applicable, utiliser la norme Standard for Manufactured
Home Installations, ANSI A225.1/NFPA 501A ou respecter
les dispositions des codes locaux.
Au Canada, l’installation de cette table de cuisson doit
satisfaire aux stipulations de la version la plus récente de
la norme CAN/CSA-A240 ou des codes locaux en vigueur.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Jenn-Air JGCP430WP Guide d'installation

Catégorie
Cuisinières
Taper
Guide d'installation
Ce manuel convient également à

dans d''autres langues