Ai POWER 9056144 Le manuel du propriétaire

Catégorie
Groupes électrogènes
Taper
Le manuel du propriétaire
PORTABLE GENERATOR
Owner’s Manual
P/N: 32082-04534-00
Model:
Serial:
Date Purchased:
SUA6000ED REV00
SAVE THIS MANUAL FOR FUTURE REFERENCE
DO NOT RETURN
TO STORE!
CALL US FIRST
1-855-888-3598
FOR SUPPORT
Table of Contents
Introduction..........................................1
Safety....................................................1
General Safety Precautions....................2
Unpacking the Generator.......................8
Parts Included........................................8
Assembly...............................................8
Install the Wheel Kit................................8
Install the Support Leg............................8
Battery Cable Connection........................9
Controls and Features..........................10
Control Panel Features........................11
Specifications.....................................12
Add Engine Oil......................................14
Low Oil Shutdown................................14
Add Fuel:Gasoline.................................14
Add Fuel:Propane/LPG..........................15
Operation at High Altitude...................16
Grounding............................................17
Connecting to a Building’s Electrical Sys-
tem......................................................17
Operation............................................18
Generator Location...............................18
Surge Protection...................................18
Before Starting the Generator................18
Starting the Engine (Generator).............18
Connecting Electrical Loads..................21
Stopping the Engine (Generator)............21
Low Oil Shutdown................................22
Do Not Overload Generator....................22
Changing Fuels.....................................22
Maintenance And Storage....................24
Maintenance Schedule.........................24
Engine Maintenance.............................24
Engine Oil Level Check.......................24
Change Engine Oil................................25
Spark Plug Maintenance.......................25
Air Filter Maintenance...........................26
Battery Replacement............................26
Cleaning the Spark Arrestor...................27
Valve Clearance...................................27
Generator Maintenance.........................27
Storage................................................27
Trouble Shooting..................................29
Parts Diagram and Parts List................30
Parts Diagram......................................30
Parts List.............................................31
Circuit Diagram....................................33
Warranty..............................................34
INTRODUCTION
SAFETY
Read This Manual Thoroughly
The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard. The
warnings in this manual and the tags and decals affixed to the unit are therefore not all-inclusive. If you use a
procedure, work method or operating technique that the manufacturer does not specifically recommend you
must satisfy yourself that it is safe for you and others. You must also make sure that the procedure work
method or operating technique that you choose does not render the generator unsafe.
If any section of this manual is not understood,
contact customer Service at 1-855-888-3598, or
www.a-ipower.com for starting, operating and
servicing procedures. The owner is responsible for
proper maintenance and safe use of the unit.
SAVE THESE INSTRUCTIONS for future reference.
This manual contains important instructions that
must be followed during placement, operation and
maintenance of the unit and its components. Always
supply this manual to any individual that will use this
unit.
The information in this manual is accurate based on
products produced at the time of publication. The
manufacturer reserves the right to make technical
updates, corrections and product revisions at any
time without notice.
Page 01
DEFINITIONS AND SYMBOLS
DANGER
Indicates a hazard
which, if not avoided,
will result in death or
serious injury.
WARNING
Indicates a hazard
which, if not avoided,
could result in death
or serious injury.
NOTICE
Indicates information
considered important,
but not hazard-related
(e.g.,messages relating
to property damage).
CAUTION
Indicates a hazard
which, if not avoided,
could result in minor
or moderate injury.
WARNING
Read and understand manual completely
before using product. Failure to
completely understand manual and
product couldresult in death or serious
injury.
WARNING
Operating, servicing, and maintaining this equipment
can expose you to chemicals including engine
exhaust, carbon monoxide, phthalates, and lead,
which are known to the State of California to cause
cancer and birth defects orother reproductive harm.
To minimize exposure, avoid breathing exhaust, and
wear gloves or wash your hands frequently when
servicing this equipment. For more information go to
www.P65warnings.ca.gov.
The words DANGER, WARNING, CAUTION, and NOTICE are used throughout this manual to highlight important
information. Make sure that the meanings of this safety information is known to all who operate, perform
maintenance on, or are nearthe generator.
This safety alert symbol appears with most safety statements. It means attention,become alert, your
safety is involved! Please read and abide by the messagethat follows the safety alerts symbol.
Engine exhaust contains carbon
monoxide, a poisonous gas that could
kill you in minutes. You CANNOT smell
it, see it, or taste it. Even if you do not
smell exhaust fumes, you could still be
exposed to carbon monoxide gas.
Asphyxiation
Hazard
Fire
Hazard
Hot Surface.
Do Not Touch the Surface.
Burn Hazard
Page 02
Kickback
Electric Shock
Hazard
Explosion
Hazard
Moving Parts
Hazard
Operator’s Manual
GENERAL SAFETY PRECAUTIONS
POISONOUS GAS HAZARD
DANGER
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust
contains carbon monoxide. This is a poison you cannot see or smell.
NEVER use inside a home or garage,
EVEN IF doors and windows are open.
Avoid other generator hazards. READ MANUAL BEFORE USE.
Only use OUTSIDE and far away
from windows, doors and vents.
The exhaust system must be properly
maintained. Do not alter or modify the
exhaust system as to render it unsafe or
make it noncompliant with local codes
and/or standards. Failure to do so will
result in death or serious injury.
DANGER
Always, install battery operated carbon
monoxide alarm indoors and installed
according to the manufacturer’s
instruction.
• Operate this product ONLY outside far away from
windows, doors and vents to reduce the risk of
carbon monoxide gas from accumulating and
potentially being drawn towards occupied spaces.
DO NOT run this product inside homes, garages,
basements, crawl spaces, sheds, or other
partially-enclosed spaces even if using fans or
opening doors and windows for ventilation. Carbon
monoxide can quickly build up in these spaces and
can linger for hours, even after this product has
shut off.
ALWAYS place this product downwind and point
the engine exhaust away from occupied spaces. If
you start to feel sick, dizzy, or weak while using
this product, shut it off and get to fresh air RIGHT
AWAY. See a doctor. You may have carbon
monoxide poisoning.
WARNING
If you start to feel sick, dizzy or weak while using
the portable generator, you may have carbon
monoxide poisoning. Get out side to fresh air
immediately and call 911 for emergency medical
attention. Very high levels of CO can rapidly cause
victims to lose consciousness before they can
rescue themselves. DO NOT attempt to shut off the
generator before moving to fresh air. Entering an
enclosed space where a generator is or has been
running may put you at greater risk of CO
poisoning.
WARNING
Page 03
• ONLY use outside and downwind, far away from windows, doors and vents.
• Direct exhaust away from occupied spaces.
CORRECT USAGE
INCORRECT USAGE
Example location to reduce risk of carbon monoxide poisoning
• Near any door, window or vent
• Garage
• Basement
• Crawl Space
• Living Area
• Attic
• Entry Way
• Porch
• Mud Room
Do not operate in any of the following locations:
Page 04
• When starting engine, pull cord slowly until
resistance is felt and then pull rapidly to avoid
kickback.
NEVER start or stop engine with electrical devices
plugged in and turned on.
Starter cord kickback (rapid retraction)
will pull hand and arm toward engine
faster than you can let go which could
cause broken bones, fractures, bruises,
or sprains resulting in serious injury.
WARNING
DANGER
Gasoline and gasoline vapors
• Gasoline is a liquid and can cause a fire or
explosion if ignited. Gasoline vapors can ignite as
well.
• Gasoline is a skin irritant and needs to be cleaned
up immediately if spilled on skin or clothes.
• Gasoline has a distinctive odor; this will help detect
potential leaks quickly.
• In case of a petroleum gas fire, do not attempt to
extinguish the flame if the fuel supply valve is in the
ON position. Introducing an extinguisher to a
generator with an open fuel supply valve could
create an explosion hazard.
• Gasoline expands or contracts with ambient
temperatures. Never fill the gasoline tank to full
capacity, as gasoline needs room to expand if
temperatures rise.
Gasoline, gasoline vapor and propane/LPG are highly
flammable and explosive.Fire or explosion can cause
severe burns or death.
DANGER
Do not overfill tank. Allow space for fuel expansion. If
fuel spills wait until it evaporates before starting
engine. Failure to do so will result in death and
serious injury.
Propane/LPG (Liquid Petroleum Gas)
• Propane/LPG is highly flammable and explosive.
• LPG is heavier than air and can settle in low places
while dissipating.
• Propane/LPG has a distinctive odor added to help
detect potential leaks quickly.
• In case of a petroleum gas fire, do not attempt to
extinguish the flame if the fuel supply valve is in the
ON position. Introducing an extinguisher to a
generator with an open fuel supply valve could
create an explosion hazard.
• When exchanging propane/ LPG cylinders, be sure
the cylinder valve is of the same type.
• Always keep the propane/LPG cylinder in an upright
position.
• Propane/LPG will burn skin if it comes in contact
with it. Keep it away from skin at all times.
WHEN ADDING OR DRAINING GASOLINE
• Turn generator engine off and let it cool at least 2
minutes before removing gasoline cap. Loosen cap
slowly to relieve pressure in gasoline tank.
• Only fill or drain gasoline tank outdoors in a
well-ventilated area.
DO NOT overfill gasoline tank. Allow space for fuel
expansion.
• If gasoline spills, wipe spilled gasoline from the unit
or wait until it evaporates before starting engine.
• Keep fuel away from sparks, open flames, pilot
lights, heat, and other ignition sources.
• Check fuel lines, tank, cap, and fittings frequently
for cracks or leaks. Replace if necessary.
DO NOT light a cigarette or smoke.
DO NOT pump gasoline directly into the generator
at the gas station. Use an approved container to
transfer the gasoline to the generator.
WHEN STARTING GENERATOR
• Ensure spark plug, exhaust system, gasoline cap,
fuel lines, propane/LPG regulator and air filter are in
place.
• Wipe spilled gasoline or wait until it evaporates
before starting engine.
• Make certain that the generator is operating firmly
on level ground.
• If you smell gasoline or propane, turn off all fuel
supplies. Make certain, there is no fuel leak before
operating the generator.
Fuel Safety
Page 05
DO NOT operate the generator inside any building,
carport, porch, mobile equipment, marine
applications, or enclosure.
DO NOT tip the generator at angle which causes
fuel to spill.
DO NOT move the generator when is running.
Gasoline, gasoline vapor and propane/LPG are highly
flammable and explosive.
Fire or explosion can cause severe burns or death.
Do not refill the gasoline tank or replace the
propane/LPG tank when the generator is operating.
Gasoline, gasoline vapor and propane/LPG are highly
flammable and explosive.
Never use a gasoline container, gasoline tank,
propane/LPG connector hose, propane/LPG cylinder
or any other fuel item that is broken, cut, torn or
damaged. Failure to do so will result in death and
serious injury.
DANGER
WHEN OPERATING THE GENERATOR
DANGER
WHEN TRANSPORTING, MOVING OR REPAIRING
EQUIPMENT
• Transport/move/repair with fuel tank EMPTY or
with fuel shutoff valve in OFF position. On dual fuel
models, be sure the propane tank is disconnected
and securely away from the generator.
DO NOT tip generator at angle which causes fuel to
spill.
• Disconnect spark plug wire.
WHEN STORING FUEL OR GENERATOR WITH FUEL
IN TANK
• Store away from furnaces, stoves, water heaters,
clothes dryers, or other appliances that have pilot
light or other ignition source because they could
ignite fuel vapors.
DANGER
Generator voltage could cause electrical
shock or burn will result in death or
serious injury.
DANGER
Never use generator in wet or damp
locations. Never expose generator to
rain, snow, water spray while in use.
Protect generator from all hazardous
weather conditions. Moisture, or ice
can cause a short circuit or other
malfunction in the electric circuit. Water
contact with a power source if not
avoided, will result in death or serious
injury.
• Use a ground fault circuit interrupter (GFCI) in any
damp or highly conductive area, such as metal
decking or steel work.
DO NOT use generator with electrical cords which
are worn, frayed, bare or otherwise damaged.
DO NOT allow unqualified persons or children to
operate or service generator.
DANGER
Contact with terminals, bare wires and
electrical connections when generator
is running will result in death or serious
injury.
DANGER
Fire and electrocution hazard. Do not connect to a
building's electrical system unless the generator and
transfer switch have been properly installed and the
electrical output has been verified by a qualified
electrician. The connection must isolate the
generator power from utility power and must comply
with all applicable laws and electrical codes.
• Store Fuel in a container approved for gasoline.
• Store any containers containing gasoline or
propane/LPG outdoor in a well-ventilated area,
away from any combustibles or source of ignition.
Page 06
WARNING
When operating machine, do not touch
hot surfaces. Keep machine away from
combustibles during use. Hot surfaces
could result in severe burns or fire.
WARNING
Exhaust heat/gases could ignite combustibles,
structures or damage fuel tank causing a fire,
resulting in death or serious injury.
Contact with muffler area could cause burns
resulting in serious injury.
• Allow equipment to cool before touching.
• Replacement parts must be the same and installed
in the same position as the original parts.
• It is a violation of California Public Resource Code,
Section 4442, to use or operate the engine on any
forest-covered, brush-covered, or grass-covered
land unless the exhaust system is equipped with a
spark arrester, as defined in Section 4442,
maintained in effective working order. Other states
or federal jurisdictions may have similar laws.
Contact the original equipment manufacturer,
retailer, or dealer to obtain a spark arrester
designed for the exhaust system installed on this
engine.
WARNING
WHEN ADJUSTING OR MAKING REPAIRS TO
YOUR GENERATOR
• Disconnect the spark plug wire from the spark plug
and place the wire where it cannot contact spark
plug.
WHEN TESTING FOR ENGINE SPARK
• Use approved spark plug tester.
DO NOT check for spark with spark plug removed.
Unintentional sparking could cause fire or electric
shock resulting in death or serious injury.
WARNING
DO NOT wear loose clothing, jewelry or anything
that could be caught in the starter or other rotating
parts.
Starter and other rotating parts could
entangle hands, hair, clothing, or
accessories. Keep away from rotating
parts, failure to do so could result in
death or serious injury.
Excessively high operating speeds could result in
minor injury. Excessively low operating speeds
impose a heavy load.
CAUTION
DO NOT tamper with governor spring, links or other
parts to increase engine speed. Generator supplies
correct rated frequency and voltage when running
at governed speed.
DO NOT modify generator in any way.
Exceeding generators wattage/amperage capacity
could damage generator and/or electrical devices
connected to it.
DO NOT exceed the generator’s wattage amperage
capacity.
• Start generator and let engine stabilize before
connecting electrical loads.
• Connect electrical loads in OFF position, then turn
ON for operation.
• Turn electrical loads OFF and disconnect from
generator before stopping generator.
NOTICE
NOTICE
Improper treatment of generator could damage it and
shorten its life.
• Use generator only for intended uses.
• If you have questions about intended use, ask
dealer or contact local service center.
• Operate generator only on level surfaces.
DO NOT expose generator to excessive moisture,
dust, dirt, or corrosive vapors.
DO NOT insert any objects through cooling slots.
• If connected devices overheat, turn them off and
disconnect them from generator.
• Shut off generator if:
-Electrical output is lost.
-Equipment sparks, smokes, or emits flames.
-Unit vibrates excessively.
Medical and Life Support Uses.
• In case of emergency, call 911 immediately.
• NEVER use this product to power life support
devices or life support appliances.
• NEVER use this product to power medical devices
or medical appliances.
• Inform your electricity provider immediately if you
or anyone in your household depends on electrical
equipment to live.
• Inform your electrical provider immediately if a loss
of power would cause you or anyone in your
household to experience a medical emergency.
WARNING
Page 07
Page 08
UNPACKING THE GENERATOR
Parts Included
Your gasoline powered generator ships with the
following parts:
NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
Qty
2
2
2
2
2
2
1
1
1
1
1
1
1
Item Description
Wheels (8.0" Flat Free)
Axle Pin
Flat Washer
Cotter Pin
Flange Bolt M8x16
Flange Lock Nut M8
Support Leg with Vibraion Mounts
Spark Plug Wrench
Oil Bottle (900ml)
Owner's Manual
Quick Start Guide
12V DC Battery Charging Cable
Propane/LPG Hose with Regulator
• Open carton completly. Remove and verify carton
content prior to assembly. Your generator ships
with following items.
• Call our customer service at 1-855-888-3598 with
the unit model and serial number for any missing
item.
• Record model, serial number, and date of purchase
on front cover of this munual for your own record.
9 10
8
11
1
2
3
4
6
5
7
ASSEMBLY
Install the Wheel Kit
NOTE:
The wheels are not intended for over-the-road use.
1 - place generator on a flat surface.
2 - Tip the generator on a piece of cardboard or
other soft material to protect the frame paint and
prevent the generator from sliding.
Your generator requires some assembly prior to
usage.
Assembly the generator will require lifting the unit.
Always have assistance when lifting the generaotor.
CAUTION
Do not plug in or turn on the generator until it is fully
assembled according to the instructions. Failure to
completely understand manual and product could
result in death or serius injury.
Call our customer service at 1-855-888-3598 for any
assembly issues or concerns. Please have model
and serial number available.
WARNING
12 13
Page 09
ASSEMBLY
NOTE:
Handle already is assembled on the unit.
IMPORTANT: Before operating the generator the
shock-absorbing seat (K) must be adjusted for
clearance. Loosen the lock nut (L) and adjust the
shock absorbing seat (K) so there is about 3-4mm
gap between the top of the seat and the bottpm of
the alternator bracket (M). Re-tighten the lock nut
after adjustment.
3-4mm
3 - Slide axle pin (A) through the wheel (B), flat
washer (C) and generator frame axles hole (D).
4 - Secure everything with cotter pin (E). Repeat on
opposite side.
Install the Support Leg
5 - Insert bolts (F) throught the support leg (G) and
holes on the generator frame as shown.
6 - Tighten bolts (F) and nuts (H) to the frame.
M
K
L
M
K
L
G
F
H
Battery Cable Connection
A
B
C
D
E
The generator is equipped with a battery charging
feauture. Once the engine is running,a small charge
will slowly recharge the battery.
If you do not plan to use the generator for a long
period of time,we recommend to DISCONNECT the
battery plugs A and B to protect the battery from
losing charge,You may also to use a battery
float charger (not included) to maintain battery
charge.
NOTICE
A
BD
C
NOTE: The generator comes equipped with the
positive cable A (with red boot) already attached.
1. Verify the positive (+) battery cable A with red
boot is securely tightened to the positive (+)
battery post. Make sure boot is over battery post.
2. Remove bolt B (M6x12) and nut C from battery
negative (-) post.
3. Locate negative (-) battery cable D with black boot
and attach to the negative (-) battery post. Tight the
cable with bolt B and nut C. Cover the post with
black boot.
Page 10
CONTROLS AND FEATURES
1 - Control Panel
2 - Fuel Valve
3 - Frame
4 - Fuel Cap
5 - Fuel Tank
6 - Fuel Gauge
7 - Spark Plug
8 - Choke Lever
9 - Air Filter
10 - Recoil Starter
11 - Engine
12 - Oil Filler Cap/Dipstick
13 - Fuel Source Switch
14 - Battery
15 - Propane/LPG inlet
16 - Alternator Cover
17 - Handle
18 - Support Leg
19 - Muffler/Spark Arrester
20 - Carbon Canister
21 - Carburator
22 - Wheel
8123 4567
2210 11 12 13 14 15 16 17 18 199 20 21
Page 11
NOTE: Total power drawn from all outlets must not exceed the nameplate rating.
CONTROL PANEL FEATURES
1. Engine Control Switch: To start engine manually,
flip the switch to RUN (I) position and pull
recoil starter. To start engine with electric start,
press and hold the switch on the START (II)
position and the engine will crank and attempts to
start. When the engine starts, release the switch
to the RUN (I) position.
2. Low Oil Indicator: The Light will be illuminated
when the engine oil level is low. Add oil.
3. 12V DC, Outlet (Automotive): Provides 12 volt
DC power up to 8.3 amps.
4. Circuit Breaker(DC): Protects the generator
against electrical overloads.
5. Circuit Breaker(AC): Protects the generator
against electrical overloads.
6. 120V AC, 20A Duplex, GFCI, Single Phase,
60 Hz Outlets (5-20R): Each outlet is capable
of carrying a maximum of 20 amps on a single
outlet or a combination of both outlets.
7. 120/240V AC, 50A, Single Phase, 60 Hz
Outlet (NEMA 14-50R): This outlet can supply
either 120 Volt or 240 Volt output up to 50 amps.
8. Ground Terminal: The ground terminal is used to
ground the generator.
9. Main Circuit Breaker: The main circuit breaker
controlstotal output ofall outlets to protect the
generator from overload or short circuit.
10. Hour Meter: Displays and records how many
hours your generator has run (up to 9,999.9).
12V
123456 7
89
10
Page 12
SPECIFICATIONS
Model
Starting Watts (Gas)
Running Watts (Gas)
Starting Watts (Propane/LPG)
Running Watts (Propane/LPG)
Rated AC Voltage
Rated DC Voltage
Rated Frequency
Phase
Grounding System (AC)
Engine Type
Engine Displacement
Starting System
Low Oil Shutdown
Oil Type
Oil Capacity
Spark Plug OEM Type
Spark Plug Replacement Type
Spark Plug Gap
Valve Intake Clearance
Valve Exhaust Clearance
Voltage Regulation System
Alternator Excitement System
Total Harmonic Distortion (THD)
Fuel Tank Capacity
Fuel Type
Maximun Ambient Temperature
Battery Spec
Certifications
SUA6000ED (10001-04403-00)
6000W
5500W
5500W
5000W
120/240V
12V
60HZ
Single
Neutral Bonded to Frame
Single Cylinder, 4-Stroke OHV Air Cooled
322cc
Recoil/Electric
Yes
10W-30
30 fl.oz (0.9L)
F7RTC
NGK BPR7ES or Champion RN9YC
0.028~0.031inch (0.7~0.8mm)
0.004~0.006inch (0.1~0.15mm)
0.006~0.008inch (0.15~0.2mm)
AVR
Brushed
Standard
4.0Gal (15.00L)
Gasoline-Propane/LPG
104°F (40°C)
12V, 14Ah
EPA-cETL Compliant
Generator Specifications
Page 13
NOTICE
This product is designed and rated for continuous operation at ambient temperatures up to 104°F(40°C). If
needed, this product can be operated at temperatures ranging from 5°F(15°C) - 122°F(50°C) for short periods.
If the product is exposed to temperatures outside of this range during storage, it should be brought back within
this range before operation. This product must always be operated outdoors in awell-ventilated area and far
away from doors, windows, and other vents.
Maximum wattage and current are subject to and limited by such factors as fuel BTU content, ambient
temperature, altitude, engine conditions, etc. Maximum power decreases about 3.5% for each 1,000 feet above
sea level, and will also decrease about 1% for each 10°F(6°C) above 60°F( 16°C) ambient temperature.
120V AC, 20A Duplex GFCI
Your generator is equipped with ground fault circuit interrupter (GFCI) receptacles. In the event of a ground fault,
a GFCI trips automatically to stop the flow of electricity and prevent serious injury. The LED Indicator Light on
the receptacle will be turn off. Press the “RESET” button located on the front of the receptacle to restore flow of
electricity. GFCI does NOT protect against circuit overloads. To ensure proper operation of the GFCI duplex,
perform this test monthly:
1. With the generator running, plug a test lamp into the GFCI receptacle. Turn the lamp on.
2. Press the “TEST” button located on the front of the receptacle to trip the device. This should immediately stop
the flow of electricity and shut off the lamp. If the electricity is not stopped, do not use this receptacle until it has
been serviced or replaced.
3. Press the “RESET” button located on the front of the receptacle to restore the flow of electricity. If the LED
Indicator Light does not come back or GFCI cannot be reset, then it must be replaced.
Receptacle
LED Indicator Light
Outlet
Reset Button
Test Button
Outlet
TEST MONTHLY
RESET
TEST
FOLLOW DIRECTIONS
A
B
Do not attempt to crank or start the engine before
it has been properly filled with the recommended
type and amount of oil. Damage due to operation
with no oil will void your warranty.
We consider the first 5 hours of run time to be the
break-in period for the unit. During the break in
period stay at or below 50% of the running watt
rating and vary the load occasionally to allow stator
windings to heat and cool. Adjusting the load will
also cause engine speed to vary and help seat piston
rings.
Add Engine Oil
We recommend using SAE 10W-30 APISJ oil for
best performance. Other high-quality detergent oils
(APISJ or higher) are acceptable. Do not use special
additives. Ambient temperature determines the
proper oil viscosity for the engine. Use the chart to
select the proper oil for the outdoor temperature
range expected.
Low Oil Shutdown
The unit is equipped with a low oil shutdown. If the
oil level becomes lower than required, the sensor will
activate a warning device or stop the engine.
If generator shuts off and the oil level is within
specifications, check to see if generator is sitting at
an angle that forces oil to shift. Place on an even
surface to correct this. If engine fails to start, the oil
level may not be sufficient to deactivate low oil level
switch. Make sure the sump is completely full of oil.
Add Fuel:Gasoline
Gasoline must meet these requirements:
• Clean, fresh, unleaded gasoline.
• Use regular UNLEADED gasoline with the generator
engine with a minimum 87 octane / 87 AKI (91RON).
Do not use E85 or E15. For high altitude use, see
"Operation at High Altitude".
DO NOT mix oil in gasoline.
DO NOT modify engine to run on alternate fuels
The engine is equipped with a low oil shut-off and
will stop when the oil level in the crankcase falls
below the threshold level.
1. Place generator on a flat, level surface.
2. Clean area around oil fill and remove yellow oil fill
cap/dipstick (A).
3. Wipe dipstick clean.
4. Using oil funnel, slowly pour contents of provided
oil bottle into oil filler neck (B) to the "H" mark on
dipstick. Be careful do not overfill. Overfilling with
oil could cause the engine to not start or hard
starting.
5. Replace oil fill cap/dipstick (A) and fully tighten.
6. Oil level should be checked prior to each use or at
least every 8 hours of operation. Keep oil level
maintained.
-20 0 20 40 60
Ambient temperature
Recommended Engine Oil Type
80 100 120
-28.9
°F
°C -17.8 -6.7 4.4 15.6 26.7 37.8 48.9
10W-30
5W-30 Full Synthetic
10W-405W-30
H
L
NOTICE
NOTICE
Gasoline and gasoline vapor are highly flammable
and explosive.Fire or explosion can cause severe
burns or death.
DANGER
Do not overfill tank. Allow space for fuel expansion. If
fuel spills wait until it evaporates before starting
engine. Failure to do so will result in death and
serious injury.
DANGER
Page 14
Page 15
1. Remove the gasoline cap (A) slowly.
2. Slowly add unleaded gasoline to gasoline tank. Be
careful not to fill above the red fuel level indicator
(B). This allows adequate space for fuel expansion.
3. Install gasoline cap and let any spilled fuel
evaporate before starting engine or wipe the spilled
gasoline.
B
A
WHEN ADDING GASOLINE
• Only fill the gasoline tank outdoors in a
well-ventilated area.
DO NOT overfill gasoline tank. Allow space for fuel
expansion.
• If gasoline spills, wipe spilled gasoline from the unit
or wait until it evaporates before starting engine.
• Keep fuel away from sparks, open flames, pilot
lights, heat, and other ignition sources.
• Check fuel lines, tank, cap, and fittings frequently
for cracks or leaks. Replace if necessary.
DO NOT light a cigarette or smoke.
DO NOT fill the tank when the generator is running
or hot.
DO NOT pump gasoline directly into the generator
at the gas station. Use an approved container to
transfer the gasoline to the generator.
NOTICE
• Only fill the tank from an approved gasoline
container. Make sure the gasoline container is
internally clean and in good condition to prevent
fuel system contamination.
• Gasoline can damage paint and plastic. Use caution
when filling the fuel tank. Damage caused by spilled
gasoline is not covered under warranty.
• Clean the fuel screen filter of debris before and after
each fueling. Remove the fuel screen filter by
slightly compressing it while removing it from the
fuel tank.
• It is important to prevent gum deposits from forming
in fuel system parts such as the carburetor, fuel
hose or tank during storage. Alcohol-blended fuels
(called gasohol, ethanol or methanol) can attract
moisture, which leads to separation and formation
of acids during storage. Acidic gas can damage the
fuel system of an engine while in storage. To avoid
engine problems, the fuel system should be emptied
before storage of 30 days or longer. See the "Long
Term Storage" section. Never use engine or
carburetor cleaner products in the fuel tank as
permanent damage may occur.
Add Fuel: Propane/LPG
DANGER
Propane/LPG is highly flammable and explosive.
Fire or explosion can cause severe burns or death.
• The provided propane/LPG hose with regulator,
works with standard 20, 30 and 40 pound capacity
cylinders with Type 1, right hand Acme threads.
Verify the re-qualification date on the tank has not
expired. Do not use rusted or damaged cylinders.
• Only use provided propane/LPG hose for safe
propane operation.
1. Make certain both gasoline and propane/LPG
valves are closed.
2. Remove the rubber protective plugs (if it is avaiable)
and attach the propane/LPG hose with regulator to
the propane/LPG inlet located on the side control
panel of the generator. Tighten with a 19mm or
adjustable wrench. DO NOT over-tighten.
3. Remove safety plug from the propane/LPG cylinder
valve (if it is available) and attach the other end of
the propane/LPG hose with regulator to cylinder
valve. Tighten the nut by hand clockwise to a
positive stop.
IMPORTANT: DO NOT use thread seal tape or any
type of sealant to seal the propane LPG hose
connections.
Operation using an alternative main jet at elevations
lower than the recommended minimum altitude can
damage the engine. For operation at lower elevations,
the standard main jet supplied must be used.
Operating the engine with the wrong main jet may
increase exhaust emissions, fuel consumption and
reduce performance.
Operation at High Altitude
At altitudes over 5,000 feet(1524 meters), a
minimum 85 octane gasoline is acceptable. Engine
power and generator output will be reduced
approximately 3.5% for every 1000 feet (305 m) of
elevation above sea level. High altitude may cause
hard starting, increased fuel consumption and spark
plug fouling. To operate at high altitudes A-iPower
can provide a high altitude carburetor main jet. The
alternative main jet and installation instructions can
be obtained by contacting Customer Support.
NOTICE
4. Open valve on propane LPG cylinder and check all
connections for leaks by wetting the fittings with a
solution of soap and water. Bubbles which appear
or bubbles which grow indicate that a leak exists.
If a leak exists at a fitting, then turn off the valve on
the cylinder and tighten the fitting. Turn the valve
back on and recheck the fitting with the soap and
water solution. If the leak continues or if the leak is
not at a fitting, then do not use the generator and
contact customer service.
NOTICE
• Use only an approved LPG cylinder equipped with
an OPD (overfilling prevention device) valve.
DO NOT check for leaks with a lighted match or
flame.
• The propane cylinder valve should be fully closed
when the generator is not in use or is running with
gasoline.
• The regulator/hose assembly and cylinder valve
must be inspected before each use for leaks or sign
of damages.
• All new cylinders must be purged of air and
moisture prior to filling. Used cylinders that have not
been plugged or kept closed must also be purged.
The purging process should be done by your
propane gas supplier.
• Propane/LPG is heavier than air and can
accumulate in confined spaces and low places in
the event of a leak
• Propane/LPG has a distinctive odor added to help
detect potential leaks quickly.
• In case of a petroleum gas fire, do not attempt to
extinguish the flame if the fuel supply valve is in the
ON position. Introducing an extinguisher to a
generator with an open fuel supply valve could
create an explosion hazard.
• When exchanging propane/ LPG cylinders, be sure
the cylinder valve is of the same type.
• Always keep the propane/LPG cylinder in an upright
position.
• Propane/LPG will burn skin if it comes in contact
with it. Keep Propane/LPG away from skin at all times.
• Always position the cylinder so the connection
between the valve and the regulator won’t cause
bends or kinks in the hose.
DO NOT light or smoke cigarettes while you are
connecting the propane/LPG cylinder.Check the fuel
system periodically for leaks or signs of damages.
• In the event of an LPG fire, flames should not be
extinguished unless by doing so the fuel supply
valve can be turned off. If the fire is extinguished
and a supply of fuel is not turned off, an explosion
hazard greater than the fire hazard could be created.
DANGER
Do not start generator if you smell propane. Always
fully close the propane tank valve and disconnect the
propane/LPG hose from the generator when not in use.
Page 16
Grounding
The national electrical requires your generator must
be connected properly to an appropriate ground to
help prevent electric shock.
The generator has a system ground that connects the
generator frame components to the ground terminals
on the AC output receptacles. There may be Federal
or State regulations, local codes, or ordinances that
apply to the intended use of the generator. Consult a
qualified electrician, electrical inspector, or the local
agency having jurisdiction. This generator is not
intended to be used at a construction site or similar
activity as defined by NFPA 70-2020 (NEC) section
590.6.
Connecting to a Building's Electrical System
Connections to your home’s electrical system must
use a listed transfer switch installed by a licensed
electrician. The connection must isolate the generator
power from the utility power and comply with all
applicable laws and electrical codes.
WARNING
Shock hazard. Failure to properly ground
the generator can result in electric shock.
Page 17
Page 18
OPERATION
Generator Location
Surge Protection
Before Starting the Generator
Make sure you review each warning in order to
prevent fire hazard.
• Keep area clear of inflammables or other
hazardous materials.
• Select a site that is dry, well ventilated and
protected from the weather.
• Keep exhaust pipe clear of foreign objects.
• Keep generator away from open flame.
• Keep generator on a stable and level surface.
• Do not block generator air vents with paper or
other material.
Electronic devices, including computers and many
programmable appliances use components that are
designed to operate within a narrow voltage range
and may be affected by momentary voltage
fluctuations. While there is no way to prevent voltage
fluctuations, you can take steps to protect sensitive
electronic equipment.
Install UL1449, CSA-listed, plug-in surge
suppressors on the outlets feeding your sensitive
equipment.
Surge suppressors come in single- or multi-outlet
styles. They’re designed to protect against virtually
all short-duration voltage fluctuations.
Select the Fuel Source (Gasoline)
1. Make certain the propane tank is fully closed.
• Make certain the generator is on a flat, level surface
and well-ventilated location. Check for loose or
missing parts and for any damage which may have
occurred during shipment.
• Check oil level and fuel.
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust
contains carbon monoxide. This is a poison you cannot see or smell.
NEVER use inside a home or garage,
EVEN IF doors and windows are open.
Avoid other generator hazards. READ MANUAL BEFORE USE.
Only use OUTSIDE and far away
from windows, doors and vents.
• Disconnect all electrical loads from the generator.
Never start or stop the generator with electrical
devices plugged in or turned on.
WARNING
DANGER
Never use generator in wet or damp
locations. Never expose generator to
rain, snow, water spray or standing
water while in use. Protect generator
from all hazardous weather conditions.
Moisture, or ice can cause a short
circuit or other malfunction in the
electric circuit. Water contact with a
power source if not avoided, will result
in death or serious injury.
Starting the Engine (Generator)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81

Ai POWER 9056144 Le manuel du propriétaire

Catégorie
Groupes électrogènes
Taper
Le manuel du propriétaire

dans d''autres langues