Vanox Nova VL36BN Operating & Maintenance Instructions

Catégorie
Cheminées
Taper
Operating & Maintenance Instructions
DANGER
Read and understand this manual. Improper installa-
tion, adjustments, alterations, service or maintenance
can cause serious injury, property damage or even
death. For assistance or additional information consult
a qualified installer, service agency or gas supplier.
NOTICE
Installer: Leave this manual with the appliance.
Do not remove.
Consumer: Retain this manual for maintenance and
future reference. Do not discard.
Installation
Operation &
Maintenance
Instructions
VANOX Fireplace Inc.
www.vanoxreplace.com
Zero clearance
BV Gas Fireplace
NOVA VL36BN
1218837
WARNING
Hot glass will cause burns.
Do not touch glass until unit
is cooled.
Never allow children to
touch glass.
CAUTION
Glass doors on gas fireplaces are extremely hot while
the fireplace is on and remain hot even after the
fireplace has been turned off. Safety screens are
available and can reduce the risk of severe burns.
Please keep children away from the fireplace at all
times.
WARNING
Do not store or use gasoline or any other flammable
vapors and liquids in the vicinity of this or any other
gas burning appliance. A fire or explosion may occur
causing serious injury, property damage or even
death.
DANGER
IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electrical switch; do not use any
phone in your building.
- Immediately call your gas supplier from your
neighbours phone. Follow the gas suppliers instruc-
tions.
- If you cannot reach your gas supplier, call the fire
department.
installation
opération &
entretien
instruction
VANOX Fireplace Inc.
dégagement zéro
BV Cheminée au gaz
NOVA VL36BN
1218837
www.vanoxreplace.com
AVERTISSEMENT
Verre chaud peut causer des
brûlures. Ne pas toucher le
verre jusqu'à ce que l'unité
est refroidie.
Ne jamais laisser les enfants
toucher la vitre.
DANGER
Lire et comprendre ce manuel. Une mauvaise installa-
tion, des ajustements, des modifications, de service ou
d'entretien peuvent causer des blessures graves, des
dommages matériels ou même la mort. Pour de l'aide
ou des renseignements supplémentaires, consultez un
installateur, une agence de service ou le fournisseur.
AVERTISSEMENT
Ne pas entreposer ni utiliser d'essence ou d'autres
vapeurs et liquides inflammables à proximité de cet
appareil ou tout autre appareil de chauffage au gaz.
Un incendie ou une explosion peut se produire et
provoquer des blessures graves, des dommages
matériels ou même la mort.
AVERTISSEMENT
Installateur: Laissez ce manuel avec l'appareil. Ne
retirez pas.
Consommateur: Conservez ce manuel pour l'entretien
et la référence future. Ne jetez pas.
DANGER
SI VOUS UNE ODEUR DE GAZ
- Ne pas tenter d'allumer l'appareil.
- Ne touchez à aucun interrupteur électrique; ne pas
utiliser le téléphone dans votre immeuble.
- Appelez immédiatement votre fournisseur de gaz à
partir du téléphone d'un voisin. Suivez les instructions
du fournisseur de gaz.
- Si vous ne pouvez pas joindre votre fournisseur de
gaz, appelez le service d'incendie.
Safety Alert Key
CAUTION
Indicates a hazardous situation which, if not avoided,
WILL result in minor or moderate injury.
ATTENTION
Indique une situation dangereuse qui, si elle n'est pas
évitée, entraînera la mort ou des blessures ou des
dommages matériels graves.
DANGER
Indicates a hazardous situation which, if not avoided,
WILL result in death or serious injury or property
damage.
Indique une situation dangereuse qui, si elle n'est pas
évitée, entraînera la mort ou des blessures ou des
dommages matériels graves.
WARNING
Indicates a hazardous situation which, if not avoided,
COULD result in death or serious injury or property
damage.
AVERTISSEMENT
Indique une situation dangereuse qui, si elle n'est pas
évitée, POURRAIT entraîner la mort ou des blessures
graves ou des dommages property.
NOTICE
Addresses practices that are important, but not
related to personal injury.
AVERTISSEMENT
Adresses pratiques qui sont importantes, mais ne
sont pas liées à des blessures.
Part. No. VL36BN-Man-072414-A
VL36BN Gas Fireplace VANOX Fireplace Inc.
Page 3
VL36BN Gas Fireplace
Safety Alert Key
Introduction ..............................................................................4
Installation
Before you Start .......................................................4 - 5
Installation Checklist....................................................5
Section 1:
Installation Overview and Product Dimensions.....6
Section 2:
Framing the Fireplace..................................................6
Installing the replace shell........................................7
Clearances ....................................................................7
Section 3:
B-Vent Installation...................................................8 - 10
Section 4:
Finishing .......................................................................11
Facing.............................................................................11
Mantels and surrounds...............................................11
Section 5:
Wiring ......................................................................12 - 14
Section 6:
Installing and Removing the Door...........................15
Section 7:
Installing the Gasline..................................................16
Section 8:
Operation, Lighting Instructions
SIT millivolt Valve ................................17 - 18
SIT IPI Valve..............................................19 - 20
Section 9:
Installing the Optional Fan Kit..............................21 - 22
Installing the Glass Media..........................................22
Installing the Drftwood log set.................................23
Opperation: .............................................................................23
Maintenance: ............................................................................24
Warranty: ....................................................................................25
Notes ........................................................................................26 - 27
Table of Contents
NOTICE
You must read and understand this manual prior
to installation, operation or troubleshooting this
appliance. Please retain this owners manual for
future reference and maintenance,
AVIS
Vous devez lire et comprendre ce manuel avant
l'installation, le fonctionnement ou le dépannage
de cet appareil. S'il vous plaît conserver ce
manuel du propriétaire pour référence et
l'entretien futur.
Introduction
Thank You for choosing a VANOX VL36 Fireplace
About the VL36BN Fireplace
The VL36-BN includes a 18,000 BTU Linear burner. The
VL36-BN is certied in Canada and USA as a Vented Gas
Fireplace (ANSI Z21.50 -2014 / CSA 2.22 -2014) and is avail-
able in two versions.
VL36BN - Millivolt Ignition)
VL36BN-E - IPI Ignition)
The VL36-BN is rated for Natural Gas at 18,000 BTU/H (7.33
Kilowatts) Input.
How to use this manual:
This manual covers all models and unless otherwise speci-
ed, the designation VL36-BN refers to all models. Sections
which are specic to a particular model are marked with a
symbol, plus the appropriate model number.
Warranty and Installation Information:
The Vanox warranty will be voided by, and Vanox disclaims
any responsibility for, the following actions:
• Modication of the replace and/or components includ-
ing glass doors.
• Use of any component part not manufactured or ap-
proved by Vanox in combination with this Vanox replace
system.
• Installation other than as instructed in this manual.
Consult your local Gas Inspection Branch on installation
requirements for factory-built gas replaces. Installation &
repairs should be done by a qualied contractor.
Installations in Canada must conform to the current CAN/
CGA B149.1 and .2 Gas Installation Code and local regula-
tions.
• Installation in the USA must conform to local codes, or in
the absence of those codes, conform to the National Fuel
gas Code, ANSI 2223.1 / NFPA54.
Before you Start
IMPORTANT MESSAGE: SAVE THESE INSTRUCTIONS
The VL36BN B- Vent replace must be installed in accor-
dance with these Instructions. Carefully read all the Instruc-
tions in this manual rst. Consult the Local Gas Branch to
determine the need for a permit prior to starting the instal-
lation. It is the responsibility of the installer to ensure this
replace is installed in compliance with the manufacturers
instructions and all applicable codes.
Installation
Part. No. VL36BN-Man-072414-A
VL36BN Gas Fireplace
VANOX Fireplace Inc.
Page 4
NOTICE
Installation and repairs should be done by an authorized
fireplace service technician. The appliance should be
inspected before use and at least annualy by a preofes-
sional. More frequent cleaning may be required due to
excessive lint from carpeting, bedding material, etc. It is
imperative that control compartments, burners and circulat-
ing air passageways of the fireplace are kept clean.
AVIS
Installation et réparations doivent être effectuées par
un technicien de service autorisé de cheminée. L'appareil
doit être inspecté avant son utilisation et au moins annualy
par un preofessional. Un nettoyage plus fréquent peut être
nécessaire en raison des peluches provenant des tapis,
literie, etc Il est impératif que les compartiments de
contrôle, les brûleurs et les passages de circulation d'air du
foyer sont propres.
CAUTION
Due to high operating temperatures, this appliance
should not be located out of traffic & away from
furniture and draperies. Children and adults should be
alerted to the hazards of the high surface temperature,
which could cause burns or clothing ignition. Young
children should be carefully supervised when they are
in the same room as the appliance. Clothing or other
flammable materials should not be palced on or near
the appliance.
ATTENTION
En raison de températures de fonctionnement
élevées, cet appareil ne doit pas être situé hors de la
circulation et loin des meubles et des rideaux. Les
enfants et les adultes doivent être sensibilisés aux
dangers de la température de surface élevée, ce qui
pourrait provoquer des brûlures ou l'inflammation des
vêtements. Les jeunes enfants doivent être surveillés
attentivement lorsqu'ils sont dans la même pièce que
l'appareil. Vêtements ou autres matériaux inflam-
mables ne doivent pas être palced sur ou près de
l'appareil.
Part. No. VL36BN-Man-072414-A
VL36BN Gas Fireplace
VANOX Fireplace Inc.
Page 5
CAUTION
Young children should be carefully supervised when
they are in the same room as this appliance. Toddlers,
young children and others may be susceptible to
accidental contact burns. A physical barrier is recom-
mended if there are at risk individuals in the house. To
restrict access to the fireplace install an adjustable
safety gate to keep toddlers, young children and
others at risk individuals out of the room and away
from hot surfaces.
ATTENTION
Les jeunes enfants doivent être surveillés attentive-
ment lorsqu'ils sont dans la même pièce que l'appareil.
Les tout-petits, les jeunes enfants et autres personnes
sont sujets aux brûlures accidentelles. Une barrière
physique est recommandée s'il ya des personnes à
risque dans la maison. Pour restreindre l'accès à la
cheminée installer une barrière de sécurité ajustable
pour éloigner les bambins, les jeunes enfants et autres
personnes à risque hors de la pièce et loin des
surfaces chaudes.
Installing Overview and Product Dimensions
Please review the Installation Checklist on Page 4 for gen-
eral information on preparing for a successful installation
of your replace. The VL36BN replace may be installed in
any location that maintains proper clearances to air condi-
tioning ducts, electrical wiring and plumbing.
Safety, as well as eciency of operation, should be consid-
ered when selecting the replace location. Select a loca-
tion that does not interfere with room trac, has adequate
ventilation and oers an accessible path for B-Vent instal-
lation.
Section 1: Installation Overview
Installation Checklist
1). Determine the desired install location of your replace.
See Section 1, Dimensions on Page 5, and refer to the
Framing. Section 2 for details.
2). Select the location of your termination and resulting
vent run. Your selected termination location must be the
highest point in the B-Vent installation.
3). Should it be impossible to meet the venting require-
ments laid out in Section 3: Venting, please contact Vanox.
4). Lay out the Vent run and Electrical Requirements Refer
to Section 4: Wiring, for Details.
5). Refer to Section 5: Installing the Gas Line, for details on
the gas connection and access. Refer to local codes and
guidelines for installation requirements.
NOTE: Installation and repairs should be done by a
qualied contractor and must conform to, below:
• Installations in the USA must conform to the local codes
or in the absence of local codes to the current version of
National Fuel Gas Code, ANSI Z223.1/NFPA 54. Electrical
Installations must conform to the local codes or, in the ab-
sence of local codes, to the current version of the National
Electrical Code, ANSI/NFPA 70. See Appendix C for
installation within the State of Massachusetts..
Section 2: Framing the Fireplace
Framing Dimensions
36”
15 1/2”
39”
Figure 1. Fireplace Locations.
E
4”
4”
AB
C
F
D
Part. No. VL36BN-Man-072414-A
VL36BN Gas Fireplace VANOX Fireplace Inc.
Page 6
VL36BN Gas Fireplace
Installing The Fireplace Shell
The replace may be installed in any location that main-
tains proper clearances to air conditioning ducts, electrical
wiring and plumbing. Safety, as well as eciency of opera-
tion, must be considered when selecting the replace loca-
tion. Try to select a location that does not interfere with
room trac, has adequate ventilation
Refer to page 4 - B-Vent Installation for more information.
The replace dimensions are shown below:
Front View Side View
Top View
Corner Installation.
Figure 3. Fireplace dimensions.
34 1/8”
9 3/8”
65 7/8”
32 7/8”
1” clearance
at corners
Clearances
These clearances apply to all dimensions except the framed
opening, where the clearance to combustibles are listed on
Page 6, Section No. 2.
The VL36-BN clearances to combustible materials are:
Top 64”
Back 1”
Side 1”
Floor 0”
Mantel 9”
Perpendicular Wall 4”
B-Vent 1”
Clearances specied by the B-vent manufacturer.
For protection against freezing temperatures, it is recommend-
ed that outer walls of the chase be insulated with a vapour
barrier. This will reduce the possibility of a cold-air convection
current on the replace.
Figure 4. Combustible Shelf location.
35 3/4”27 1/8”
16 1/4”
4 3
/
8”
A
A
6 3/4”
1”
Fresh Air
Inlet
14 1/2”
64”
Flue collar
Shelf
Floor /
Hearth
Min.
12’-0”
1”
1”
Back Wall
2” non-
combustible
board
Part. No. VL36BN-Man-072414-A
VL36BN Gas Fireplace
VANOX Fireplace Inc.
Page 7
enclosure
Rain cap / termination
Attic
insulation
shield
ceiling
Floor
ceiling framing
4” B-Vent only
Floor / hearth
Min.
12’-0” feet
roof framing
Storm collar
The VL36BN is certied for use with standard 4” and 5” inch
B-Vent, and requires no B-Vent appliance connector. Simply
attach the B-Vent to the replace ue collar, and secure it
using 1/4” sheet metal screws.
Refer to the current CAN/CGA B-149.1 or ANSI Z223.1 /
NFPA54, gas Installation Code for specic vent sizing.
Notes:
The replace requires a MIN. 12’-0” feet vertical
rise in order operate correctly.
If more than 12’-0” feet of B-Vent is used on vent
runs, use ceiling supports.
For reducing to the 4”B-Vent, use the BV increas-
ing adapter on top of the 5” Fireplace ue collar.
Fireplace can be supplied with the 4” or the 5” col-
lar from the factory.
4” B-Vent installation
See the detailed drawings below and determine which
installation best suits your application. Follow all the pre-
scribed details installations as shown. Failing to do so can
create an unsafe condition, which to lead to a re, safety
hazard, injury or death.
Figure 5. Straight through ceiling and roof installation, for 4”
inch B-Vent installation.
Section 3: B-Vent Installation
enclosure / chase
Attic
insulation
shield
Floor / hearth
4” & 5” B-Vent
ceiling framing
Floor framing
ceiling framing
Rain cap / termination
Storm collar
Min.
12’-0” feet
Figure 6. Max. 12” oset for 4” inch B-Vent ONLY.
CAUTION
Test your B-Vent installation after completion to ensure
that no combustible by-products are spilling from the
fireplace opening. This draft test should be performed
after a ten (10) minute warm up period. The manufac-
turer will not be responsible for any installations with
inadequate draw.
ATTENTION
Testez votre installation B-Vent après l'achèvement de
s'assurer qu'aucun combustible des sous-produits se
propageaient de l'ouverture du foyer. Ce projet de test
doit être effectué après dix (10) minutes
d'échauffement période. Le fabricant ne sera pas
responsable de toutes les installations avec tirage
insuffisant.
Part. No. VL36BN-Man-072414-A
VL36BN Gas Fireplace VANOX Fireplace Inc.
Page 8
VL36BN Gas Fireplace
enclosure
Rain cap / termination
ceiling
Floor
ceiling framing
5” B-Vent
Floor / hearth
Min.
12’-0” feet
roof framing
Storm collar
5” B-Vent
Figure 7. Max. 26” oset, (multi-bends) for 5” inch B-Vent
installation.
Installation of VL36BN replace with
Tjernlund Power Vent and insulated
aluminum ex.
Minimum enclosure requirements: Ensure all up-stream
PV joints from PV are sealed with High temperature sili-
cone sealant.
NOTE: If clearances are below 64” non-combustible materi-
als, (steel studs and concrete board) MUST BE USED. For
further information contact replace manufacturer.
Figure 8. Power Vent system, wiring with Tjernlund Power
Vent Motor.
ceiling
Floor
ceiling
f
raming
Floor / hearth
Min. 64”
exterior
exhaust
M
Power Vent exhaust
Motor
5
Wiring Diagram with VANOX PV1500
Powervent
Figure 7a. Powervent with VANOX PV1500.
NOTES:
1) All ex venting components must be insulated with Fire
rated insulation.
2).
- Clearances to cumbustibles: for PVM (Motor) 4” all around.
- Clearances to cumbustibles: for BV pipe = 1”
- Clearances to cumbustibles: for insulated ex = 3”
3). Some corner installations with power vent (only) may
require vent adapter (oset box), part number V0B5 to con-
nect the replace ue with existing 5” custom muer. The
oset box MUST be insulated after it is connected.
120V
ceiling
Floor
Power
Supply
Floor / hearth
VL36BN
Valve 24V Relay (PVR)
Blue Green
24V
Min.
12’-0” feet 24V
Red
White
Wall Switch
PVEB
PVM
Red
Air Switch
(PVAS) 120V
MAX
10 feet
Part. No. VL36BN-Man-072414-A
VL36BN Gas Fireplace VANOX Fireplace Inc.
Page 9
VL36BN Gas Fireplace
115VAC,
60Hz
inta
k
e
exhaust
Power Vent
Air
switch
24V
Relay
BLU
GRN
WHT
RED
Wall switch
TH
TPTH
SIT
Terminal
Dry
contacts
24V
Relay TP
TH
TPTH
Robert
Shaw
Dry
co
n
tacts
Existing Wood
Chase, with 10”
diameter vent
Floor / hearth
Relief opening
Rain cap / termination
Min.
12’-0” feet
4”/5” Flex, or Rigid
B-Vent pipe.
pipe.
Steel pipe
Conrming proper venting of Appliance.
To check for proper drafting use this procedure.
1). Place unit in operation and allow to run for approximately
(5)-minute to establish a up-draft.
2). Using a match or something that will produce smoke,
place it up to the opening of the draft hood and verify that
the ame or smoke is being drawn into the draft hood. If the
ame or smoke is blown away from the draft hood open-
ing. You may have to re-check the venting and verify there
is a minimum of 12’-0” feetof venting, or check the house for
negative pressure.
Installation with 4”diameter aluminum venting into an exist-
ing type A wood replace Chase.
Spill Switch
Relief Opening
Figure 9. VL36BN Wiring diagram with millivolt system.
Figure 10. VL36BN installation where a wood replace
chase exists.
Figure 9a. PVEB Wiring diagram.
Part. No. VL36BN-Man-072414-A
VL36BN Gas Fireplace
VANOX Fireplace Inc.
Page 10
Non-combustible
board.
38L”
2”
9”
8”
7”
6”
20”
18”
12” 9”
Finishing Around the Fireplace
Combustible mantels and mouldings may be safely installed
over the top and on the front of the replace. The VL36BN
requires a minimum 2”x 38”L. Non-combustible board on
top of the upper ange.
Mantels & Surrounds
NOTE: National Canadian Gas Association mantel test
requirements are for re hazard prevention to combustible
materials.
New technology, to meet consumer and government
demands for the wise use of energy, has prompted us to
manufacture many models of replaces which are hot, fuel
and energy ecient.
Please be aware; temperatures over the mantel will rise above
normal room temperature and walls above replace may be
hot to touch.
We recommend careful consideration be given to the eects
of elevated mantel temperatures which may be in excess of
product design, for example: candles, plastic or pictures. This
can cause melting, deformation, discoloration or premature
failure of T.V. and radio components.
Section 4: Finishing
Figure 13. Combustible framing clearances above replace.
Painting:
Special care is recommended by the Master Painters and
Decorators Association, when painting the replace sur-
rounds, to select and apply a quality Alkyd sealer prior to the
applying of latex paints. This is to prevent leaching of water
from evaporation and causing a brownish staining eect to
paint over coats.
Figure 12. Combustible mantel clearances above replace..
6”
Min. 9” 7 1/2”
Flue collar
Relief opening
Door
Access panel
MUST NOT BE
O
B
S
R
UC
TED
2 x 4 wood stud @ 39”
Mantel
Drywa
ll
6 3/4”
Combustion
Air
2” non-combustible board
Fireplace Mantle
When selecting the nish material for your replace, it
is important to remember the following: THE RELIEF
OPENING MUST NOT BE OBSTRUCTED IN ANY WAY - to
do so restricts the air supply for the draft hood and heat
exchanger it also prevents access for servicing of the limit
switch.
The face of the replace may be painted to match the room
decor, provided you use a heat-resistant paint. Decorative
facing must not extend past the replace opening at all,
because it will interfere with the access to retainers for
removal of glass door.
Figure 10. Combustible mantles and facings.
DO NOT COVER the lower Access Cover, as shown in
Figure No. 13. The result will be an obstruction of the
incoming Combustion Air, and A FIRE COULD RESULT.
Refer to the current CAN/CGA B-149.1 and .2 or ANSI
Z223.1 / NFPA54 Gas Installation Code for specic vent
sizing.
Part. No. VL36BN-Man-072414-A
VL36BN Gas Fireplace VANOX Fireplace Inc.
Page 11
VL36BN Gas Fireplace
Gas Control and Pilot Wiring
SIT Millivolt Valve, 820.618, with On/o.
Section 5: Wiring
Figure 16. SIT Millivolt valve, VL36BN Fireplace.
Figure 14. Finishing materials above Relief opening.
Finishing materials can be Flush with TOP of Relief
opening, but MUST NOT COVER opening. Lower
panel must be left uncovered for access to internal
components, burner, optional fans, electrics, etc.
Door
Ceramic Tile
Relief opening
Blue wire to
Valve coil
Pilot hood
Thermopile
Safety Spill Switch
Black wire
Black wire
ON-OFF
Thermopile
Blue wire con-
nected to Valve
Flue 5” dia.
or 4” dia.
Relief opening
DO NOT COVER
THIS AREA
2 x 4 wood stud
Door Frame
Drywall
7 1/2”
39”32 1/2”
2”
WARNING
Combustible objects must not be placed on a non-n-
combustible mantel unless the non-combustible
mantel meets the minimum height and width require-
ments for a combustible mantel.
AVERTISSEMENT
Objets combustibles ne doivent pas être placés sur un
manteau non combustible à moins que le linteau
incombustible est conforme aux exigences de hauteur
et largeur minimum pour un manteau combustible.
NOTICE
RELIEF OPENING MUST NOT BE COVERED WHEN
ADDING FINISHING MATERIALS AROUND FIRE-
PLACE OPENING. See figure 14 above, and Figure
15 below.
AVIS
SECOURS D'OUVERTURE doit pas être recouverte
LORS DE L'AJOUT matériaux de finition autour de la
cheminée OUVERTURE. Voir figure 14 ci-dessus, et la
figure 15 ci-dessous.
NOTICE
RELIEF OPENING MUST NOT BE COVERED WHEN
ADDING FINISHING MATERIALS AROUND FIRE-
PLACE OPENING. See figure 14 above, and Figure
15 below.
AVIS
SECOURS D'OUVERTURE doit pas être recouverte
LORS DE L'AJOUT matériaux de finition autour de la
cheminée OUVERTURE. Voir figure 14 ci-dessus, et la
figure 15 ci-dessous.
Part. No. VL36BN-Man-072414-A
VL36BN Gas Fireplace
VANOX Fireplace Inc.
Page 12
Gas Control and Pilot Wiring: IPI System
Spill Switch
Figure 17. IPI Electronic gas valve, VL36BN Fireplace.
WARNING
Electrical grounding instructions. This appliance is
equipped with a three-pronged (grounding) plug for
your protection against shock hazzard and should be
plugged directly into a properly grounded three-e-
pronged receptacle. Do not cut or remove the ground-
ing prong from the plug.
AVERTISSEMENT
Électriques instructions de mise à la terre. Cet
appareil est équipé d'un à trois broches (mise à la
terre) prise pour votre protection contre les chocs
hazzard et doit être branchée directement dans une
prise à trois broches. Ne pas couper ou enlever la
broche de terre de la fiche.
Part. No. VL36BN-Man-072414-A
VL36BN Gas Fireplace VANOX Fireplace Inc.
Page 13
Figure 18. VL36BN Spill Switch.
Spill Switch:
The VL36BN gas replace uses the 820.618 and Robert-Shaw 7000 Series True Millivolt Systems. This System does not have a
thermocouple.
Safety Spill Switch
Thermopile
Thermopile
ON-OFF
Black wire Black wire
Pilot hood
Blue wire to
Valve coil
Side view
Millivolt Valve
Blue wire
connected
to Valve
WARNING
- Do not clean glass when hot.
- Do not use abrasive cleaners.
- Using a substitute glass will void all product warran-
ties.
- Do not strike or abuse glass. Care must be taken to
avoid breakage of glass
- Do not operate this fireplace without the glass front or
with broken glass.
AVERTISSEMENT
- Ne pas nettoyer la vitre lorsqu'elle est chaude.
- Ne pas utiliser de nettoyants abrasifs.
- Utilisation d'un verre de remplacement annulera
toutes les garanties.
- Ne pas frapper ou malmener la vitre. Des précau-
tions doivent être prises pour éviter les bris de verre
- Ne pas faire fonctionner ce foyer sans les portes en
verre ou avec du verre brisé.
Part. No. VL36BN-Man-072414-A
VL36BN Gas Fireplace
VANOX Fireplace Inc.
Page 14
Section 6: Removing the Door
Figure 20. Remove lower Access Cover.
Figure 21. Lower Access Cover removed.
Figure 22. Release Hasp.
Figure 23. Removal of Screen.
Removing the door & Safety Screen:
The VL36BN door is removed in a few simple steps. Follow
these instructions below to remove the Horizontal access
panel, unlatch the door buckles and, remove the door.
Replace in reverse order.
Buckle
Part. No. VL36BN-Man-072414-A
VL36BN Gas Fireplace VANOX Fireplace Inc.
Page 15
VL36BN Gas Fireplace
Buckle
Gasline Installation:
This gas appliance should be installed by a qualied
installer in accordance with local building codes and with
current CAN/CGA - B149.1 or .2 installation codes for Gas
Burning appliances and equipment in Canada.
Installations in the USA must conform to the local codes
or in the absence of local codes to the current version of
National Fuel Gas Code, ANSI Z223.1/NFPA 54. Electrical
Installations must conform to the local codes or, in the ab-
sence of local codes, to the current version of the National
Electrical Code, ANSI/NFPA 70. See Appendix C for
installation within the State of Massachusetts..
1. The gas pipeline can be brought in ONLY through the
left side of the appliance. A knockout is provided at either
location to allow for the gas pipe installation and testing of
any gas connection.
2. The gas control inlet is 3/8” NPT.
3. When using copper or ex connector, use only approved
ttings. Always provide a union so that gas line can be
easily disconnected for burner or fan servicing. See gas
specication for pressure details and ratings.
4. When a vertical section of gas pipe is required for the
installation, a condensation trap is needed. See CAN/CGA-
B149.1 or .2 for code details.
5. For natural gas, a minimum of 3/8” iron pipe with gas
minimum pressure of 5.5 w.c. must be used for supply from
the gas meter. Consult with the local gas utility if any ques-
tions arise concerning pipe sizes.
6. 1/8” NPT plugged tappings are accessible for test gauge
connection both on the inlet and outlet of the gas valve.
7. Turn the gas supply ON and check for leaks. DO NOT USE
OPEN FLAME FOR THIS PURPOSE. Use an approved leak
testing solution.
8. The appliance and its individual shuto valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of 1/2 PSIG (3.5 KPa).
9. The appliance must be isolated from the gas supply
piping system by closing its individual shuto valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 PSIG (3.5 KPa).
Section 7: Installing the Gasline
Figure 25. Gas Line / Valve Installation.
Copper
Rigid pipe
SIT control
valve
Gas Specications and Ratings:
Model
VL36BN - NG - Millivolt; 18,000 BTU/h
VL36BNE - NG - IPI; 18,000 BTU/h
Gas Inlet
Gas Supply Min. 5.5 WC
Max. 14.7 WC
Manifold Pressure; 3.5 WC
Orice Size, #47dms; air shutter closed.
WARNING
A Qualified Electrician must connect electrical wiring
to junction outlet for built-in installation.
AVERTISSEMENT
Un électricien qualifié doit raccorder le câblage
électrique à la sortie de la jonction pour l'installation
intégrée.
WARNING
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper or danger-
ous operation. Verify proper operation after servicing.
AVERTISSEMENT
Identifiez tous les fils avant de les débrancher lors
des contrôles. Les erreurs de câblage peuvent
provoquer un mauvais fonctionnement ou dangereux.
Vérifier le bon fonctionnement après l'entretien.
Part. No. VL36BN-Man-072414-A
VL36BN Gas Fireplace
VANOX Fireplace Inc.
Page 16
Section 8: Operation: Lighting Instructions
SIT Millivolt Valve:
Part. No. VL36BN-Man-072414-A
VL36BN Gas Fireplace VANOX Fireplace Inc.
Page 17
Part. No. VL36BN-Man-072414-A
VL36BN Gas Fireplace
VANOX Fireplace Inc.
Page 18
SIT Millivolts Valve:
SIT IPI Valve:
Part. No. VL36BN-Man-072414-A
VL36BN Gas Fireplace VANOX Fireplace Inc.
Page 19
Part. No. VL36BN-Man-072414-A
VL36BN Gas Fireplace VANOX Fireplace Inc.
Page 20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Vanox Nova VL36BN Operating & Maintenance Instructions

Catégorie
Cheminées
Taper
Operating & Maintenance Instructions

dans d''autres langues