Modern Forms WS-W22514 Kyoto Mode d'emploi

Taper
Mode d'emploi
Installation Instructions
Item number: WS-W22510
WARNING
IMPORTANT: NEVER attempt any work without shutting off the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualified electrician in accordance with the National Electrical Code
and local regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew
the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the fixture or room that you
are working on.
- Place the wall switch in the “OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use
any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of
this fixture.
CAUTION When handling the fixture, do not apply pressure to the LEDs. Hold the fixture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d'installer.
- Système est destiné à être installé par un électricien qualif en conformité avec le code national de
l'électricité et les règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur
principal en position d’arrêt (« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les
pièces, n'en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces
instructions peut annuler l’homologation ETL/CETL du luminaire.
MISE EN GARDE
Ors de la manipulation de l'appareil, ne pas appliquer de pression à la LED, tenir l'appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje
e instalación de esta lámpara.
- Sistema está disenado para ser instalado por un electricista calificado, de acuerdo con el código eléctrico
nacional y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el
interruptor de alimentación principal en la posición “OFF” (APAGADO).
- Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita
piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría
invalidar la calificación ETL/CETL esta lámpara.
PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
Hardware
PREPARATION
1. Shut off the power at the circuit breaker and
remove existing fixture, including the
mounting hardware.
2. Carefully unpack your new fixture and lay out
all the parts on a clear area. Be careful not to
lose any small parts necessary for installation.
CONNECTING THE WIRES (Fig. 2)
3. Connect the fixture wires to supply wires as
shown in Fig. 2, making sure that all wire
connectors (C1) are secured. If your outlet box
has a green or bare copper ground wire, connect
the fixture’s ground wire to it. Otherwise, connect
the fixture’s ground wire directly to the mounting
plate (D1) using the green screw provided. After
wires are connected, tuck them carefully inside
the junction box.
MOUNTING THE FIXTURE (Fig. 1)
4. Secure the mounting plate (D1) to the junction
box (A1) using the junction box screws (B1). The
side of the mounting plate marked “GND” must
face out.
5. Place the fixture frame (G1) over the mounting
plate (D1) and secure with gasket (F1) mounting
screws (E1, two at the bottom, J1, two at the top).
6. Put the glass (K1) to the fixture frame (G1) from
the top and put the metal frame (H1) on the glass
(K1) secure it to the mounting plate (D1) with
screws (E1) and gasket (F1).
COMPLETING THE INSTALLATION (Fig. 3)
7. To prevent moisture from entering the outlet box
and causing a short, use clear caulking
(i.e. indoor/outdoor silicone sealant) to outline
the outside of fixture back plate where it meets
the wall. Leave a space at the bottom to allow
moisture to escape (Fig.3)..
Fig.1
Modern Forms
www.modernforms.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. NOVEMBER, 2016 1
HARDWARE
WARNING
IMPORTANT: NEVER attempt any work without shutting o the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF”
the circuit breaker switch(es) that control the power to the xture or room that you are working on.
- Place the wall switch in the “OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are
worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture.
CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les
règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt
(« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté
et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du
luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta
lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación
principal en la posición “OFF” (APAGADO).
- Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni
utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación
ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
C1 E1 F1 J1 L1
Wire Connector
Qty: 3pc
Plastic
Anchor
Qty: 2pc
I1B1
Fixture Screw
Qty: 5pc
+ 1 extra
Set Screw
Qty: 1pc
+ 1 extra
Gasket
Qty: 5pc
+ 1 extra
Wood Screw
Qty: 2pc
Junction Box
Screw
Qty: 2pc
+ 1 extra
INSTALLATION INSTRUCTION
Kyoto - Exterior
WS-W22514
Modern Forms
www.modernforms.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. NOVEMBER, 2016 2
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig.2 Wiring
PREPARATION
- Shut o the power at the circuit breaker and remove existing xture, including the mounting hardware.
Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
CONNECTING THE WIRES
1. Connect the xture wires to supply wires as shown in Fig. 2, making sure that all wire connectors (C1) are secured. If your outlet box has
a green or bare copper ground wire, connect the xtures ground wire to it. Otherwise, connect the xtures ground wire directly to the
mounting plate (D1) using the green screw provided. After wires are connected, tuck them carefully inside the junction box (A1).
2. Drill the holes in the proper position on the wall according to the keyholes located on the mounting plate (D1). Insert the plastic anchors
(I1) into the wall.
3. Secure the mounting plate (D1) to the junction box using the junction box screws (B1). Fasten mounting plate (D1) to the wall using the
wood screws (J1). The side of the mounting plate marked “GND” must face out.
4. Place the xture frame (G1) over the mounting plate (D1) and secure with set screws (E1), two at the bottom (L1), two at the top and
gasket (F1).
5. Put the glass (K1) to the xture frame (G1) from the top and put the metal frame (H1) on the glass (K1) secure it to the mounting plate (D1)
with screws (E1) and gasket (F1).
COMPLETING THE INSTALLATION
6. To prevent moisture from entering the outlet box and causing a short, use clear caulking (i.e. indoor/outdoor silicone sealant) to outline the
outside of xture back plate where it meets the wall. Leave a space at the bottom to allow moisture to escape Fig.3
Junction Box
Caulking
Fig.3 Sealing
Fig.1
J1L1 I1
C1
B1
D1
F1
E1
G1
H1
E1 F1
Junction Box Screw
Wire Connector
Anchor
Mounting Plate
Gasket
Fixture Screw
Junction Box
Fixture Frame
Screw
Wood Screw
Fixture Screw, Gasket
Metal Frame
Glass
INSTALLATION INSTRUCTION
Kyoto - Exterior
WS-W22514
1⁄”
3¾”
3¾”
10¾”
1¾”
4¼”
Back Plate Dimensions
Modern Forms
www.modernforms.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. NOVEMBER, 2016 1
HARDWARE
WARNING
IMPORTANT: NEVER attempt any work without shutting o the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF”
the circuit breaker switch(es) that control the power to the xture or room that you are working on.
- Place the wall switch in the “OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are
worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture.
CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les
règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt
(« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté
et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du
luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta
lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación
principal en la posición “OFF” (APAGADO).
- Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni
utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación
ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
C1 E1 F1 J1
Wire Connector
Qty: 3pc
Plastic
Anchor
Qty: 2pc
I1B1
Fixture Screw
Qty: 5pc
+ 1 extra
Gasket
Qty: 5pc
+ 1 extra
Wood Screw
Qty: 2pc
Junction Box
Screw
Qty: 2pc
+ 1 extra
INSTALLATION INSTRUCTION
Kyoto - Exterior
WS-W22520
L1
Set Screw
Qty: 1pc
+ 1 extra
Modern Forms
www.modernforms.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. NOVEMBER, 2016 2
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig.2 Wiring
PREPARATION
- Shut o the power at the circuit breaker and remove existing xture, including the mounting hardware.
Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation
MOUNTING THE FIXTURE (FIG. 1)
1. Drill holes in the proper position on the wall according to the keyholes located on the mounting plate (D1). Insert the plastic anchors (I1)
into the wall.
2. Secure the mounting plate (D1) to the junction box (A1) using the junction box screws (B1). Fasten mounting plate (D1) to the wall using the
wood screws (J1). The side of the mounting plate marked “GND” must face out.
3. Lock the metal hook (M1) of the safety cable onto the mounting plate.
CONNECTING THE WIRES
4. Connect the xture wires to supply wires as shown in Fig. 2, making sure that all wire connectors (C1) are secured. If your outlet box has
a green or bare copper ground wire, connect the xtures ground wire to it. Otherwise, connect the xtures ground wire directly to the
mounting plate (D1) using the green screw provided. After wires are connected, tuck them carefully inside the junction box (A1).
5. Place the xture frame (G1) over the mounting plate (D1) and secure with set screws (E1) two at the bottom (L1), two at the top and
gasket (F1).
6. Put the glass (K1) in the xture frame (G1) from the top and put the metal frame (H1) on the glass (K1) secure it to the mounting plate (D1)
with screws (E1) and gasket (F1).
COMPLETING THE INSTALLATION
7. To prevent moisture from entering the outlet box and causing a short, use clear caulking (i.e. indoor/outdoor silicone sealant) to outline the
outside of xture back plate where it meets the wall. Leave a space at the bottom to allow moisture to escape Fig.3
Junction Box
Caulking
Fig.3 Sealing
M1
L1
J1
I1
C1
B1
D1
F1
E1
G1
H1
E1 F1
Junction Box Screw
Wire Connector
Anchor
Mounting Plate
Gasket
Fixture Screw
Metal Hook
Junction Box
Fixture Frame
Wood Screw
Fixture Screw, Gasket
Metal Frame
Glass
Screw
Fig.1
INSTALLATION INSTRUCTION
Kyoto - Exterior
WS-W22520
16¼” 12¼”
1¾” 6¾”
12¼”
Back Plate Dimensions
1⁄”
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Modern Forms WS-W22514 Kyoto Mode d'emploi

Taper
Mode d'emploi