Cooper Lighting ASYX 2 - WM - Wall Mount Guide d'installation

Taper
Guide d'installation
INS #
Brand Logo
reversed out of
black
INS #
IL525006EN
ASYX 2.0
SL-S1-S2 Wall Installation Instructions
Description: The ASYX 2.0 second generation of asymmetric lighting is designed for general ambient illumina-
tion and accenting architectural features. The luminaire allows for both forward and wide distributions as well
four different color temperatures to accommodate any space. The ASYX 2.0 utilizes the patented and highly effi-
cient AccuLED Optics TM system for industry leading performance. IP66 rated
Construction: Heavy-wall die cast aluminum end caps with extruded aluminum housing. Housing fins allow for
air flow and thermal management. Fixture housing is coated using electrostatically charged polyester powder
coat paint for superior protection against fade and wear.
WARNING
Risk of burn. Use protective gear to ensure to ensure
personal safety.
WARNING
Proper grounding is required to ensure personal
safety.
WARNING
Risk of Electric Shock. Disconnect power at fuse or
circuit breaker before installing or servicing.
WARNING
Risk of Fire/Electric Shock. If not qualified, consult
an electrician.
IMPORTANT: Read carefully before installing fixture. Retain for future reference.
ote:N This product must be installed in accordance
with the applicable installation code by a certi-
fied electrician, familiar with the construction and
operation of the product and hazards involved.
ote:N To prevent wiring damage or abrasion, do not
expose wiring to edges of sheet metal or any
sharp objects.
ote:N Fixture in compliance with UL 1598 and UL 8750.
ote:N Wet locations listed.
ote:N MAX ambient temperature 40°C for all small
fixtures.
ote:N All electrical wire from junction box to fixture
head to be provided by others and follow local
codes.
ote:N Ensure mounting surface can support fixture
head(s) and entire fixture assembly.
ote:N Ensure all screws are torqued to proper settings.
WARNING
Disconnect all power before proceeding with
installation.
2
EATON IL525006EN ASYX 2.0 Wall SL - S1 - S2 Installation Instructions
ASYX 2.0 Installation Instructions - WALL - Types SL - S1 - S2
1. Unpack ASYX 2.0 wall fixture and ensure that all
included parts are present. (Figure 1.)
Figure 1.
INSTALLATION
Steel Cable
Dimming
Leads
(if dimmers
are used)
Line Voltage
Leads
2. Locate wall junction box and attach Universal Mounting
plate using (4) #10-32 screws. Pull line voltage wires
through center hole of mounting plate. Make sure
longer slot is in the upward direction. (Figure 2.)
Figure 2.
3. Feed all line voltage wires through center hole of
mounting plate. (Figure 4). Connect wires with
wire nuts.
Figure 3.
Universal
Mounting Plate
Surface
Canopy Box
- 4-Gang
Junction Box
The following are included if the “C” (Surface Mount
Box with Conduit Entry) is selected
Slot on
Universal
Mouting
Plate
Steel cable
Foam Gasket
on back of
plate
(4) #10-32
screws
(4) #1/4-20 screws
Fixture Head
Black - Hot
White - Neutral
Green - Ground
Purple - 0-10V (+)
Gray - 0-10V (-)
Wiring Table:
Note: Not included and to be provided by others:
- Waterproof wires nuts
IL525006EN
2 of 4
09/29/2015
3. Hang fixture head on mounting plate using steel
cable attached to fixture head. Ensure fixture hangs
securely from mounting plate. (Figure 3.)
ASYX 2.0 Installation Instructions - WALL - Types SL - S1 - S2
3
EATON IL525006EN ASYX 2.0 Wall SL - S1 - S2 Installation Instructions
7. Repeat steps 2 through 7, but mount to Surface Canopy
Box junction box provided. (Figure 7.)
4. Connect fixture leads to line voltage power, per
local code with waterproof wire nuts. Tuck wires
into junction box. (Figure 4.)
Figure 4.
Figure 5.
Figure 6.
5. Lift fixture head and tighten (4) #10-32 screws into
mounting plate at hole locations. (Figure 5).
Waterproof wire
nuts by others
6. To level and adjust angle of fixture head, loosen knuckle
bolt with socket wrench, and use an allen wrench to
adjust aiming by turning set screw on top of fixture to
desired angle. (Figure 6).
Figure 7.
Set Screw
Knuckle
Bolt
IL525006EN
3 of 4
09/29/2015
For Surface Canopy Option (“C”):
Eaton
18001 E. Colfax Avenue
Aurora, CO 80011
P: 770-486-4800
www.eaton.com/lighting
Canada Sales
5925 McLaughlin Road
Mississauga, Ontario L5R 1B8
P: 905-501-3000
F: 905-501-3172
© 2015 Eaton
All Rights Reserved
Printed in USA
Imprimé aux États-Unis
Impreso en los EE. UU.
Publication No. IL525006EN
09/29/2015
Eaton is a registered trademark.
All trademarks are property
of their respective owners.
Eaton est une marque de commerce
déposée. Toutes les autres marques
de commerce sont la propriété de leur
propriétaire respectif.
Eaton es una marca comercial
registrada. Todas las marcas
comerciales son propiedad de sus
respectivos propietarios.
Product availability, specifications,
and compliances are subject to
change without notice
La disponibilité du produit, les
spécifications et les conformités
peuvent être modifiées sans préavis
La disponibilidad de productos, las
especificaciones y los cumplimientos
están sujetos a cambio sin previo aviso
Warranties and Limitation of Liability
Please refer to www.eaton.com/LightingWarrantyTerms for our terms and conditions.
Garanties et limitation de responsabilité
Veuillez consulter le site www.eaton.com/LightingWarrantyTerms pour obtenir les conditions générales.
Garantías y Limitación de Responsabilidad
Visite www.eaton.com/LightingWarrantyTerms para conocer nuestros términos y condiciones.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Cooper Lighting ASYX 2 - WM - Wall Mount Guide d'installation

Taper
Guide d'installation