Faber SYNT36SS300 Installation Instructions (PDF)

Catégorie
Hottes
Taper
Installation Instructions (PDF)
Version 07/11- Page 1
SYNTHESIS
(Electronic Controls)
Wall Mount Canopy Rangehood
READ AND SAVE THESE INSTRUCTIONS
The Installer must leave these instructions with the homeowner.
The homeowner must keep these instructions for future reference
and for local electrical inspectors' use.
• Installation Instructions
• Use and Care Information
READ THESE INSTRUCTIONS BEFORE YOU START INSTALLING THIS RANGEHOOD
WARNING: - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite.
Heat oils slowly on low or medium setting.
b) Always turn hood ON when cooking at high heat or when ambeing food
(i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or lter.
d) Use proper pan size. Always use cookware appropriate for the size of the surface element.
WARNING: - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE
THE FOLLOWING (*):
a) SMOTHER FLAMES with a close-tting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PRE-
VENT BURNS. If the ames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - You may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.
d) Use an extinguisher ONLY if:
1) You know you have a Class ABC extinguisher, and you already know how to operate it.
2) The re is small and contained in the area where it started.
3) The re department is being called.
4) You can ght the re with your back to an exit.
(*) Based on “Kitchen Firesafety Tips” published by NFPA.
ALL WALL AND FLOOR OPENINGS WHERE THE RANGEHOOD IS INSTALLED MUST BE SEALED.
This rangehood requires at least 24" of clearance between the bottom of the rangehood and the cooking surface or countertop.
This minimum clearance may be higher depending on local building code. For example, for gas ranges, a minimum of 30" is
recommened and may be required. Overhead cabinets on both sides of this unit must be a minimum of 18" above the cooking
surface or countertop. Consult the cooktop or range installation instructions given by the manufacturer before making any
cutouts.
LISEZ BIEN CETTE FICHE AVANT D'INSTALLER LA HOTTE
AVERTISSEMENT - POUR MINIMISER LE RISQUE D’UN FEU DE GRAISSE SUR LA TABLE DE CUISSON : a) Ne jamais laisser
un élément de la table de cuisson fonctionner sans surveillance à la puissance de chauffage maximale; un renversement/
débordement de matière graisseuse pourrait provoquer une inammation et le génération de fumée. Utiliser toujours une
puissance de chauffage moyenne ou basse pour le chauffage d’huile. b) Veiller à toujours faire fonctionner le ventilateur
de la hotte lors d’une cuisson avec une puissance de chauffage élevée ou lors de la cuisson d’un mets à amber (i.e.
Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé). c) Nettoyer fréquemment les ventilateurs d’extraction. Veiller
à ne pas laisser de la graisse s’accumuler sur les surfaces du ventilateur ou des ltres. d) Utiliser toujours un ustensile
de taille appropriée. Utiliser toujours un ustensile de taille adapté à la taille de l’élément chauffant.
AVERTISSEMENT: - POUR PRÉVENIR LES BLESSURES EN CAS DE FEU SUIVRE LES RECOMMANDATIONS SUIVANTES
(*): a) ÉTOUFFEZ LE FEU avec un couvercle métallique et fermez le brûleur. Si le feu ne s'éteint pas tout de suite, QUIT-
TEZ LES LIEUX ET APPELEZ LES POMPIERS. b) NE TOUCHEZ JAMAIS UNE CASSEROLE EN FLAMMES. c) N'UTILISEZ
JAMAIS DE L'EAU ou un torchon mouillé pour éteindre le feu - ce qui pourrait causer une explosion de vapeur. d) N'utilisez
un extincteur que si: 1. Vous avez un modèle ABC et vous connaissez bien son mode d'emploi. 2. Le feu est petit et peu
répandu. 3. Les pompiers sont déjà prévenus. 4. Vous avez une sortie derrière vous. (*) Basé sur la "cuisine Firesafety
incline" édité par NFPA.
TOUTE OUVERTURE DANS LE MUR OU LE PLANCHER À PROXIMITÉ DE LA HOTTE DOIT ÊTRE SCELLÉ
Gardez 24 po. de hauteur entre le bas de la hotte et la surface de cuisson. Cette hauteur minimum peut être plus haute suivant
le code municipal. Par exemple, les cuisinières à gaz peuvent requérir 30 po. de hauteur. Les armoires au-dessus de chaque
côté devront être au moins à 18 po. au-dessus de la surface de cuisson. Consultez la che technique avant de découper les
armoires.
Version 07/11- Page 2
VENTING REQUIREMENTS
Determine which venting method is best for your application.
Ductwork can extend either through the wall or the roof.
The length of the ductwork and the number of elbows should
be kept to a minimum to provide efcient performance. The
size of the ductwork should be uniform. Do not install two
elbows together. Use duct tape to seal all joints in the ductwork
system. Use caulking to seal exterior wall or oor opening
around the cap.
Flexible ductwork is not recommended. If it is used,
each foot of exible ductwork used is equivalent to
two feet of straight metal ductwork when calculating
the ductrun length. Thus, a exible elbow equals two
standard elbows.
Make sure there is proper clearance within the wall or oor
for exhaust duct before making cutouts. Do not cut a joist or
stud unless absolutely necessary. If a joist or stud must be
cut, then a supporting frame must be constructed.
FOR MORE SPECIFIC DUCTWORK INFORMATION, GO
TO PAGE 4.
WARNING - To Reduce The Risk Of Fire, Use Only Metal
Ductwork.
ELECTRICAL REQUIREMENTS
A 120 volt, 60 Hz AC-only electrical supply is required on a
separate 15 amp fused circuit. A time-delay fuse or circuit
breaker is recommended. The fuse must be sized per local
codes in accordance with the electrical rating of this unit as
specied on the serial/rating plate located inside the unit
near the eld wiring compartment. THIS UNIT MUST BE
CONNECTED WITH COPPER WIRE ONLY. Wire sizes
must conform to the requirements of the National Electrical
Code, ANSI/NFPA 70 - latest edition, and all local codes and
ordinances. Wire size and connections must conform with the
rating of the appliance. Copies of the standard listed above
may be obtained from:
National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
• Venting system MUST terminate outside the
home.
• DO NOT terminate the ductwork in an attic or
other enclosed space.
• DO NOT use 4" laundry-type wall caps.
• Flexible-type ductwork is not recommended.
• DO NOT obstruct the ow of combustion and
ventilation air.
• Failure to follow venting requirements may result
in a re.
This appliance should be connected directly to the fused
disconnect (or circuit breaker) through exible, armored or
nonmetallic sheathed copper cable. Allow some slack in the
cable so the appliance can be moved if servicing is ever nec-
essary. A UL Listed, 1/2" conduit connector must be provided
at each end of the power supply cable (at the appliance and
at the junction box).
When making the electrical connection, cut a 1 1/4" hole
in the wall. A hole cut through wood must be sanded until
smooth. A hole through metal must have a grommet.
WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC
SHOCK, do not use this fan with any solid-state speed
control device.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI-
CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING: Use this unit only in the manner intended
by the manufacturer. If you have any questions, contact
the manufacturer.
Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting means
to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a
tag, to the service panel.
CAUTION: For General Ventilating Use Only. Do Not
Use To Exhaust Hazardous or Explosive Materials and
Vapors.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI-
CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING: Installation Work And Electrical Wiring Must
Be Done By Qualied Person(s) In Accordance With All
Applicable Codes And Standards, Including Fire-Rated
Construction.
Sufcient air is needed for proper combustion and
exhausting of gases through the ue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
When cutting or drilling into wall or ceiling, do not dam-
age electrical wiring and other hidden utilities.
Ducted fans must always be vented to the outdoors.
WARNING
• Electrical ground is required on this rangehood.
• If cold water pipe is interrupted by plastic,
nonmetallic gaskets or other materials, DO NOT
use for grounding.
• DO NOT ground to a gas pipe.
• DO NOT have a fuse in the neutral or grounding
circuit. A fuse in the neutral or grounding circuit
could result in electrical shock.
• Check with a qualied electrician if you are in doubt
as to whether the rangehood is properly grounded.
• Failure to follow electrical requirements may result
in a re.
WARNING
For residential use only.
!
!
Cold Weather installations
An additional back draft damper should be installed to minimize
backward cold air ow and a nonmetallic thermal break should be
installed to minimize conduction of outside temperatures as part of
the vent system. The damper should be on the cold air side of the
thermal break. The break should be
as close as possible to where the
vent system enters the heated portion of the house.
Version 07/11- Page 3
RÈGLEMENTS D'ÉVACUATION
Conrmer la sortie d'évacuation - soit par le mur, soit par
le toit.
Utilisez une longueur de tuyauterie minimale avec les moindres
de coudes pour la plus grande efcacité. Le diamètre de
tuyauterie doit être uniforme. N'installez jamais 2 coudes
ensemble. Scellez bien tous les joints avec un ruban adhésif
métallique à l'intérieur et scellez bien le clapet extérieur avec
du calfeutrage.
Utilisez un tuyau d'évacuation rigide lorsque possible.
Un tuyau exible égale deux fois plus qu'un tuyau rigide,
ce qui réduit la puissance d'évacuation.
Veillez à ce que l'espace pour le tuyau soit ample - ainsi on
n'aurait pas besoin de découper les supports de mur intérieur.
Si ce découpage est nécessaire, veillez bien à ce qu'un
renforcement soit mis en place.
Pour de meilleurs résultats, utilisez un tuyau de transition de
9 pouces dès que possible.
RÈGLEMENTS D'ÉVACUATION ADDITIONELL - PAGE 10.
AVERTISSEMENT - Pour Ne Pas Risquer Un Feu, Utilisez
Seulement Les Matériaux Métalliques.
Veillez a ce qu'un contact d'un demi-pouce (1/2 po.) soit
installé à chaque bout de l (soit à l'appareil ainsi qu'à la
boite à fusible).
Faites un trou de 1 1/4 po. dans le mur. S'il s'agit d'un trou en
bois - sablez-le bien, tandis qu'un trou passant par le métal
demande un bouche-trou.
AVERTISSEMENT - POUR RÉDUIRE LE RISQUE
D'INCENDIE OU DE CHOC ELECTRIQUE, ne pas utiliser
ce ventilateur en conjonction avec un dispositif de réglage
de vitesse à semi-conducteurs.
AVERTISSEMENT – POUR MINIMISER LES RISQUES
D’INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES
CORPORELS, OBSERVER LES PRESCRIPTIONS
SUIVANTES: Suivez les recommandations du fabricant
et entre en communication avec lui pour toute
information.
Fermez le courant avant tout entretien et veillez a ce qu'il
reste fermé. Si on ne peut pas verrouiller le panneaux
du service électrique, afchez un avis de danger sur la
porte.
AVIS: Pour L'évacuation Générale - Veillez à Ne Pas
Evacuer Des Matériaux Ou Vapeurs Explosif.
AVERTISSEMENT – POUR MINIMISER LES RISQUES
D’INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES
CORPORELS, OBSERVER LES PRESCRIPTIONS
SUIVANTES: L'installation Et Le Raccordement Electrique
Doivent Se Faire Par Un Technicien Qualié Selon Tous
Les Codes Municipaux.
An d'obtenir un rendement maximal en ce qui a trait à la
combustion ainsi qu'à l'évacuation des gaz par la conduite
de cheminée, une bonne aération est nécessaire pour
tous les appareils à combustion. Suivez les conseils et
mesures de sécurité du fournisseur tels que ceux publiés
par l'Association Nationale de la Sauvegarde contre
l'Incendie et l'Association Américaine d'Ingénieurs de
Chauffage, Frigorifaction et Air Climatisé ainsi que les
codes municipaux.
En perçant un mur veillez à ne pas perforer un autre l
électrique.
Une ventilateur à évacuation exrieure doit être
raccordée à l'extérieur.
AVERTISSEMENT
• Le système d'évacuation DOIT sortir à l'extérieur.
• N'ÉVACUEZ PAS le conduit soit dans une
mansarde soit dans un espace enfermé.
• N'UTILISEZ PAS un clapet de séchoir à 4 pouces.
• N'utilisez pas un conduit exible.
• N'ENCOMBREZ PAS la circulation d'air.
• Faute de suivre cet avertissement pourrait
occasionner un feu.
FICHE TECHNIQUE ÉLECTRIQUE
Le raccordement électrique doit se faire avec un circuit séparé
de 15 ampères fusible à 120V, 60 Hz, courant alternant. On
recommande un coupe-circuit. La taille du fusible doit se
conformer aux codes municipaux suivant la spécication
électrique sur la plaque intérieure. Le diamètre du l
devra aussi se conformer aux règlements du code national
électrique, ANSI/NFPA 70 - ainsi qu'aux règlements locaux
et les spécications de cet appareil. On peut obtenir ces
informations chez:
l'Association Nationale de la Prévention du Feu
Batterymarch Park
Quincy, Massachusetts 02269
Raccordez cet appareil directement au coupe-circuit avec un
l exiblle couvert en cuivre en laissant un peu de lâchement
dans le l pour permettre le déplacement de l'appareil.
• Une prise à terre est nécessaire pout cette hotte.
• N'utilisez pas un tuyau à l'eau froide pour la mise
à terre s'il est branché à un joint plastique, non-
métallique ou autre.
• NE JOIGNEZ PAS la mise à terre à conduit de gaz.
• N'INSTALLEZ PAS un fusible dans le circuit de
mise à terre - ce qui peut causer une secousse
électrique.
• Vériez avec un électricien certié à ce que la hotte
soit bien mise à terre.
• Faute de suivre ces recommandations pourrait
occasionner un feu.
AVERTISSEMENT
Uniquement pour usage menager.
!
!
Installations pour régions à climat froid
On devrait installer un clapet antireux additionnel pour minimiser le
reux d'air froid, et incorporer un élément non métallique d'isolation
thermique pour minimiser la conduction de chaleur par l'intermédiaire
du conduit d'évacuation, de l'intérieur de la maison à l'extérieur. Le
clapet anti-reux doit être placé du côté air froid par rapport à l'élément
d'isolation thermique. L'isolant thermique doit être aussi proche que
possible de l'endroit le système d'évacuation s'introduit dans la
partie chauffée de la maison.
Version 07/11- Page 4
Includes: Lower Chimney with holes for ducting Ductless
Diverter • Vent Grates • Two Charcoal Filters
Ductless Conversion Kit/
Kit Pour Conversion Du Conduit
Stainless
DUCTSYNT
Replacement Charcoal Filters/Filtres au Charbon
6093034
High Ceiling Chimney Kit/
Kit D'extension Pour La Cheminée Plafond Haut
One 40” upper chimney (S) to replace 16
3/8”
upper chimney (S) that came with hood
Stainless
HIGHSYNT
OPTIONAL ACCESSORIES AND DIMENSIONS / ACCESSOIRES POUR L’INSTALLATION
30"
-
Version 07/11- Page 5
TOOLS NEEDED FOR INSTALLATION
• Saber Saw or Jig Saw
• Drill
• 1 1/4" Wood Drill Bit
• Pliers
• Phillips Screwdriver
• Flat Blade Screwdriver
• Wire Stripper or Utility Knife
• Metal Snips
• Measuring Tape or Ruler
• Level
• Pencil
• Caulking Gun
• Duct Tape
PARTS SUPPLIED FOR INSTALLATION
• 1 Hardware Package
• 1 Literature Package
PARTS NEEDED FOR INSTALLATION
• 2 Conduit Connectors
• Power Supply Cable
• 1 Wall or Roof Cap
All Metal Ductwork
9 Feet Straight Duct
2 - 90˚ Elbows
Wall Cap
Total System
9.0 feet
10.0 feet
0.0 feet
19.0 feet
FIGURE 3
3.0 feet
5.0 feet
12.0 feet
0.0 feet
45˚ Elbow
90˚ Elbow
90˚ Flat Elbow
Wall Cap
FIGURE 2
CALCULATE THE DUCTRUN LENGTH
The ductrun should not exceed 35 equivalent feet
if ducted with the required minimum of 6" round
ductwork. Calculate the length of the ductwork
by adding the equivalent feet in FIGURE 2 for
each piece of duct in the system An example
is given in FIGURE 3.
For best results, use no more than three 90°
elbows. Make sure that there is a minimum of
24" of straight duct between elbows if more
than one is used. Do not install two elbows
together. If you must elbow right away, do it
as far away from the hood's exhaust opening
as possible.
WARNING
Because of the weight and size of the
rangehood canopy, two or more people
are needed to move and safely install the
rangehood canopy.
Failure to properly lift rangehood could
result in damage to the product or personal
injury.
PERSONAL INJURY HAZARD
PLAN THE INSTALLATION
This rangehood can be installed as either ducted or ductless. In a ducted
application, this rangehood can be vented through the wall or ceiling. To vent
through a wall, a 90° elbow is used. When installed ductless, the rangehood
vents out of grates on the sides of the chimney. Ductless installations require
a Ductless Conversion Kit, available from your dealer.
WARNING! BEFORE MAKING ANY CUTS OR HOLES FOR INSTALLATION,
DETERMINE WHICH VENTING METHOD WILL BE USED AND CAREFULLY
CALCULATE ALL MEASUREMENTS.
RANGEHOOD COMPONENTS
FIGURE 1
A. CANOPY SECTION
B. LOWER CHIMNEY COVER
C. UPPER CHIMNEY COVER
D. CANOPY MOUNTING BRACKETS
E. CANOPY MOUNTING BRACKET
F. MOUNTING SCREWS
G. CHIMNEY MOUNTING BRACKETS
H. DAMPER
I. CHIMNEY SCREWS
ADJUSTMENT SCREWS
!
G
I
H
Version 07/11- Page 6
1” min
16
3/8” max
22”
9
1/2”
36”
x
also consult cooktop
manufacturer's recommendation
upper
chimney
lower
chimney
canopy
x = distance from hood to cooktop
(varies depending on installation)
min - 24”, suggested max - 30”
cabinet base
FIGURE 4
19 1/4”
PREPARE THE WALL
1. Disconnect and move freestanding range from cabinet
opening to provide easier access to upper cabinet and rear
wall. Put a thick, protective covering over cooktop, set-in
range or countertop to protect from damage or dirt.
2. Determine and clearly mark with a pencil the center line
on the wall where the rangehood will be installed.
3. The canopy attaches to the wall by two mounting brackets
(1 in FIGURE 5). The canopy of the rangehood hangs on
the two brackets which must be mounted with the anges
on the top of the bracket and pointing away from the wall.
Before installing the brackets, the adjustment screws must
be installed into the bottom of the bracket. These two
screws are provided in the hardware package and have
hexagon heads with a slot for a at blade screwdriver.
The dimensions illustrate mounting the canopy 24" above
the cooking surface.
4. The chimney mounts by two brackets (2 in FIGURE 5).
Note the position of the brackets. The top bracket should
be installed about 1/8" away from the ceiling. The bottom
bracket must be installed at the bottom point of the upper
chimney sleeve.
Determine the proper location for each bracket and install
the brackets on the wall. MAKE SURE THAT THE BRACK-
ETS ARE SECURELY FASTENED TO THE WALL.
5. Determine and make all necessary cuts in the wall for the
ductwork. Install the ductwork before the rangehood.
6. Determine the proper location for the Power Supply
Cable (FIGURE 6). Use a 1 1/4" Drill Bit to make this
hole. Run the Power Supply Cable. Use caulking to seal
around the hole. DO NOT turn on the power until instal-
lation is complete.
INSTALLATION DIMENSIONS
The Synthesis chimneys are adjustable and designed to meet varying ceiling
heights as indicated in FIGURE 4. The chimneys can be adjusted for ceil-
ings between 7' 8 1/2" and 9' 5 7/8" depending on the distance between
the bottom of the hood and the cooktop (distance x in FIGURE 4).
FIGURE 5
FIGURE 6
30 MODELS
36 MODELS
For shorter ceilings,
have the chimney
cover(s) cut at a sheet
metal shop. For higher
ceiling installations, the
High Ceiling Chimney
Kit includes a new 40”
upper chimney which
would replace the 16
3/8” upper chimney that
came with the hood.
min & max ceiling height examples
x = 30"
min
8'
2 1/2"
max
9'
5 7/8"
x = 28"
min
8'
1/2"
max
9'
3 7/8"
x = 26"
min
7'
10 1/2"
max
9'
1 7/8"
x = 24"
min
7'
8 1/2"
max
8'
11 7/8"
Version 07/11- Page 7
3. Remove the cover from the eld wiring compartment. Remove
the wiring electrical knockout using a at-blade screwdriver. Feed
the Power Supply Cable through the electrical knockout.
4. Hang the canopy on the brackets (1 in FIGURE 8). There are
two rectangular holes on the rear of the canpoy. The brackets
pass through these holes and the canopy hangs from the anges
on the brackets. Due to the weight of the canopy, two people
should lift it to avoid injuries. Make sure that the canopy is
secure on the brackets before releasing.
5. Level the canopy. The height and level of the canopy can
be adjusted by rotating the adjustment screws (W in FIGURE
8) on each side of the blower inside the rangehood.
INSTALL THE RANGEHOOD
1. Remove the unit from the carton and place on a at surface
for assembly. Cover the surface to prevent accidental dam-
age. Remove all parts including the mounting hardware before
discarding the carton.
2. Remove the grease lters from the unit and set aside. The
grease lters are removed by pressing the handle in front of the
lter (FIGURE 7). When replacing, make sure that the lters are
properly positioned with the handles in front and visible.
6. Connect the Power Supply Cable to the rangehood. Attach
the White lead of the power supply to the White lead of the
rangehood with a twist-on type wire connector. Attach the Black
lead of the power supply to the Black lead of the rangehood with
a twist-on type wire connector. Connect the Green (Green and
Yellow) ground wire under the Green grounding screw.
7. Replace the eld wiring compartment cover and the grease
lters.
8. For ducted installations, the damper must be attached to the
exhaust opening on the top of the canopy. Connect the ductwork
and seal all connections with duct tape.
FOR DUCTLESS INSTALLATIONS
Do not use the DAMPER (I In FIGURE 1) for ductless
installations. The UPPER CHIMNEY COVER must be installed
rst, before the LOWER CHIMNEY DUCTLESS.
Ductless installations require a Ductless Conversion Kit. This
kit consists of a LOWER CHIMNEY DUCTLESS (A in FIGURE
9) with holes for the exhaust air, a DUCTLESS DIVERTER (C),
two VENT GRIDS (B) to cover the holes in the chimney cover,
and two CHARCOAL FILTERS (D). The DUCTLESS DIVERTER
must be installed before the LOWER CHIMNEY DUCTLESS
is attached (as indicated by the arrow in FIGURE 9). The
LOWER CHIMNEY COVER without holes (B in FIGURE 1)
should be discarded.
FIGURE 9
Once the LOWER CHIMNEY DUCTLESS with holes is installed,
the VENT GRIDS (B) are inserted into the holes (FIGURE 10).
B
Attach the CHARCOAL FILTERS to both sides of the blower (as
indicated in FIGURE 11). Install the grease lters.
FIGURE 10
FIGURE 11
FIGURE 8
FIGURE 7
Version 07/11- Page 8
FIGURE 13
9. The chimney must be attached to the body of the rangehood, as indicated in FIGURE 12. The UPPER CHIMNEY COVER (C)
must be installed rst, then the LOWER CHIMNEY COVER (B) wraps around it. Both sections are secured to the wall under the
CHIMNEY MOUNTING BRACKETS (H). Secure the UPPER CHIMNEY COVER to the MOUNTING BRACKETS with the CHIMNEY
SCREWS (J). Secure the LOWER CHIMNEY COVER to the CANOPY SECTION (A) with the CHIMNEY SCREWS (J).
FIGURE 12
10. Turn the power supply on. Turn on blower and light. If the rangehood does not operate, check that the circuit breaker is not
tripped or the house fuse blown. If the unit still does not operate, disconnect the power supply and check that the wiring connec-
tions have been made properly.
USE AND CARE INFORMATION
This rangehood system is designed to remove smoke, cooking vapors and odors from
the cooktop area.
For Best Results
Start the rangehood several minutes before cooking to develop proper airow. Allow the
unit to operate for several minutes after cooking is complete to clear all smoke and odors
from the kitchen.
Cleaning
The metal grease lters should be cleaned frequently in hot detergent solution or washed
in the dishwasher. Stainless steel cleaner should be used on stainless rangehoods.
Abrasives and scouring agents can scratch stainless steel nishes and should not be
used to clean nished surfaces.
Replacing the Lamps
Before attempting to replace the lamps, make sure that the light switch is turned off.
Remove the 2 screws (as indicated in FIGURE 14) that hold the light support and gently
pull the support down from the hood. Remove the lamp from the light support and replace
with new lamp. Replace the light support and x it into place with the 2 screws.
An alternative method to replace the lamps is to use a 1 1/4" suction cup (FIGURE 15).
Attach the suction cup to the bulb and pull rmly down on the bulb and replace with a
new lamp.
FIGURE 14
Version 07/11- Page 9
WIRING DIAGRAM
DIAGRAMME DE CÂBLAGE
• This rangehood uses 20 watt Halogen Lamps. / Cette hotte utilise les ampoule halogènes de 20 W.
CONTROL PANELS AND WIRING DIAGRAMS PANNEAU DE COMMANDES & DIAGRAMMES DE CÂBLAGE
0 1 2 3 4 5 6 7 8 9
Creato da.
Rev :
Ver :
DOLCE CORRADO
Materiali: non deveno contenere Pb, Cr6+, Hg, PBB, pbde, ai sensi della direttiva 2002/95 CE
SCHEMA ELETTRICO M8-4V ESB FARETTI
Non rilevare quote dal grafico non ap portare modifiche senza l'autorizzazione d'ufficio progettazione
a termini di legge ci riserviamo la prop rieta' del presente disegno con divieto di riproduzione totale o parziale
Code :
Disegno N :
Data:
08.Set.2010
LINE IN
120Vac
60Hz ~
L
N
Y-G
WIRING BOX
BLU
RED
BLK
WHT
Y-G
1
2
3
4
5
6
BLK
V1
MC
F
V2
ESB
0
MOTOR
1
MOTOR
BRW
GRY
BLU
123
6 5 4
789
1 2 3
654
987
RED
M8 4V
120V ~
WHT
BRW
2
SPEED
BLU
BLK
1
1
BLK
BLK
WHT
2
2
WHT
ORG
BRW
3
3
BRW
GRY
4
4
GRY
RED
WHT
BLU
Y-G
BLU
5
5
BLU
3/I
SPEED
RED
6
6
RED
WHT
7
7
WHT
VLT(ORG)
8
8
VLT(ORG)
RED(ORG)
9
9
RED(ORG)
RED
10
10
RED
VLT
11
11
VLT
0-1
LIGHT
12
12
TOROIDAL
TRANSFORMER
WHT
4
3
BLK
RED
2
1
BLK
N
L
V4
L
V3
ORG
2
1
RED
ORG
4
3
VLT
WHT
1
2
3
4
5
6
ORG
WHT
BRW
GRY
ORG
RED(ORG)
VLT(ORG)
RED
VLT
PRI.
SEC.
ELECTRONIC
TRNSFORMER
VLT
RED
HALOGEN
LAMPS
VLT
INCANDESCENT
LAMP
RED
HALOGEN
LAMPS
HALOGEN
LAMPS
HALOGEN
LAMPS
Rangehood Control Panel
The control panel is located under the front of the canopy. The
position and function of each control button are noted below
(FIGURE 15).
Light On/Off Button ( L )
On/Off switch for the halogen lights. Press the light button to turn
the light ON. and again to turn off.
Blower Off Button ( M )
Off switch for the blower. The blower can be operated by pressing
any of the speed buttons
Blower Speed Button ( V )
Speed control for blower. Press the switch "1" for LOW speed,
"2" for MEDIUM speed and "3" for HIGH speed. Hold down the
speed 3 button for 5 seconds to activate the intensive speed. Which
operates the hood for 10 minutes on the high speed and then returns
the previous speed.
FIGURE 15 - 3-SPEED / 3 VITESSE
Panneau de commandes
Le panneau de commandes est situé sur le moyen sous la hotte.
La position et la fonction de chaque bouton sont indiquées à la
(FIGURE 15)
Bouton marche-arrêt de la lumière (L)
Interrupteur marche-arrêt pour la lumière. Régler à « 1 » pour mettre
en circuit (ON) et à « 0 » pour mettre hors circuit (OFF).
Ventilateur outre de bouton (M)
Outre du commutateur pour le ventilateur. Le ventilateur peut être
actionné en appuyant sur les boutons l'uns des de vitesse
Bouton de vitesse du ventilateur (V)
Commande de vitesse pour le ventilateur. Pressez le " de
commutateur ; 1" ; pour à vitesse réduite, " ; 2" ; pour la vitesse
MOYENNE et le " ; 3" ; pour la vitesse. Maintenez le bouton de
la vitesse 3 pendant 5 secondes pour activer la vitesse intensive.
Ce qui fonctionne le capot pendant 10 minutes sur la vitesse et
renvoie alors la vitesse précédente.
L
V
M
Version 07/11- Page 10
FABER WARRANTY & SERVICE (SAVE FOR YOUR RECORDS)
All Faber products are warranteed against any defect in materials or workmanship for the
original purchaser for a period of 1 year from the date of original purchase. This warranty
covers labor and replacement parts. To obtain warranty service, contact the dealer from
whom you purchased the rangehood, or the local Faber distributor. If you cannot identify
a local Faber distributor, contact us at (508) 358-5353 for the name of a distributor in your
area.
The Following is not covered by Faber's warranty:
1. Service calls to correct the installation of your range hood, to instruct you how to use your
range hood, to replace or repair house fuses or to correct house wiring or plumbing.
2. Service calls to repair or replace range hood light bulbs, fuses or lters. Those
consumable parts are excluded from warranty coverage.
3. Repairs when your range hood is used for other than normal, single-family
household use.
4. Damage resulting from accident, alteration, misuse, abuse, re, ood, acts of God,
improper installation, installation not in accordance with electrical or plumbing codes, or
use of products not approved by Faber.
5. Replacement parts or repair labor costs for units operated outside the United States or
Canada, including any non-UL or C-UL approved Faber rangehoods.
6. Repairs to the hood resulting from unauthorized modications made to the
rangehood.
7. Expenses for travel and transportation for product service in remote locations and pickup
and delivery charges. Faber range hoods should be serviced in the home.
Record Your Information Below:
Serial #: __________________________
Date of Purchase: ______________
Version 07/11- Page 11
9 pi de conduit droit
2 Coudes 90˚
Capuchon de mur
Système total
9,0 pi
10,0 pi
0,0 pi
19,0 pi
FIGURE 3
3,0 pi
5,0 pi
12,0 pi
0,0 pi
Coude 45˚
Coude 90˚
Coude plat 90˚
Capuchon de mur
FIGURE 2
CALCUL DE LONGUEUR DU CONDUIT
La longueur du conduit ne doit jamais excéder
35 pi s’il s’agit de conduit rond de 6 po. Calculer
la longueur du conduit en ajoutant l’équivalent
en pied de la FIGURE 2 pour chaque pièce du
conduit du système. Un exemple est donné à
la FIGURE 3. Pour de meilleurs résultats,
ne pas utiliser plus de trois coudes de 90
o
.
S’assurer qu’il y ait un minimum de 24 po
de conduit droit entre les coudes si l’on
utilise plus d’un coude. Ne pas installer
deux coudes ensemble.
AVERTISSEMENT
À cause du poids et de la dimension de la
hotte, deux ou plusieurs personnes sont
nécessaires pour déplacer et installer la
hotte de façon sécuritaire.
Si la hotte n’est pas soulevée de façon
appropriée, il peut en résulter des
dommages au produit ou des blessures.
RISQUE DE BLESSURE
FIGURE 1
PLAN DE L’INSTALLATION
Cette hotte peut être installée avec ou sans conduit. Pour une installation
avec conduit, la ventilation peut s’effectuer par le mur ou le plafond. Pour
une ventilation par le mur, un coude de 90˚ est utilisé. Lorsque installée sans
conduit, la ventilation s’effectue par des grilles sur les côtés de la cheminée.
Les installations sans conduit requièrent un Kit Pour Conversion Du Conduit
disponible chez le marchand.
AVERTISSEMENT! AVANT DE FAIRE UNE COUPE OU DES TROUS POUR
L’INSTALLATION, DÉTERMINER QUELLE MÉTHODE DE VENTILATION SERA
UTILISÉE ET CALCULER LES MESURES DE FAÇON PRÉCISE.
CALCUL DE LONGUEUR DU CONDUIT
OUTILS NÉCESSAIRES À L’INSTALLATION
• Scie sauteuse ou à découper
• Perceuse
• Foret à bois 1 1/4 po
• Pinces
• Tournevis Phillips
• Tournevis à lame plate
• Dénude l ou couteau tout usage
• Pince coupante à l métallique
• Ruban à mesurer ou règle
• Niveau
• Crayon
• Outil à calfeutrer
• Ruban à conduit
PIÈCES FOURNIES POUR L’INSTALLATION
• 1 nécessaire de ferrures
• 1 nécessaire de documentation
PIÈCES NÉCESSAIRES POUR L’INSTALLATION
• 2 connecteurs de conduit
• Câble d’alimentation
• 1 capuchon de mur ou de toit
• Conduit en métal
ASSEMBLAGE DE LA HOTTE
A. HOTTE
B. CHEMINÉE INFÉRIEURE
C. CHEMINÉE SUPÉRIEURE
D. FIXATIONS DE LA HOTTE
E. LES VIS D'AJUSTEMENT
F. LES VIS DE FIXATIONS
G. FIXATIONS DE CHEMINÉE
H. LE REGISTRE
I. LES VIS DE CHEMINÉE
DE LA HOTTE
!
G
I
H
Version 07/11- Page 12
modèle 30
modèle 36
couvercle
cheminée
supérieure
couvercle
cheminée
inférieure
hotte
x = distance entre la hotte et la
table de cuisson
min - 24 po, suggested max - 30 po
cabinet base
FIGURE 4
19 1/4 po
Pour plafonds petit,
coupez les covercle
cheminée(s). Pour
plafonds haut, utilisez
le Kit D'extension
Pour La Cheminée
Plafond Haut (Une
cheminée supérieure
de 40 po pour réplacer
l'original cheminée
supérieure de 16
3/8 po).
1 po min
16
3/8 po max
22” po
9
1/2” po
36 po
x
DIMENSIONS D’INSTALLATION
La cheminée Synthesis est réglable pour différentes hauteurs de plafond,
entre 7 pi 8 1/2 po and 9 pi 5 7/8 po (regardez la distance entre la hotte
et la table de cuisson - x en FIGURE 4. Cela s’accomplit en utilisant
plus ou moins du couvercle de la cheminé supérieure.
PRÉPARATION DU MUR
1. Débrancher et enlever la cuisinière an d’avoir un
meilleur accès aux armoires supérieures et au mur arrière.
Placer un recouvrement épais sur la plaque de cuisson,
la cuisinière encastrée ou le dessus du comptoir pour
protéger des dommages et de la poussière.
2. Déterminer et marquer clairement, à l’aide d’un crayon,
la ligne centrale sur le mur où la hotte sera installée.
3. La hotte Synthesis s’installe au mur avec deux xations
(1 de la FIGURE 5). La hotte est suspendue par deux
xations qui doivent être installées avec les collerettes sur
le dessus de la xation et pointant vers l’extérieur du mur.
Avant d’installer les xations, installer les vis de réglage
au bas de la xation. Ces deux vis sont fournies dans
le nécessaire de ferrures et ont des têtes hexagonales
avec une encoche pour un tournevis à lame plate. Les
dimensions à la FIGURE 5 sont pour l’installation de la
hotte à 24 po au-dessus du plan de travail.
4. La cheminée s’installe au mur par deux xations (2 de
la FIGURE 5). Noter la position des xations. La xation
supérieure doit être installée à environ 1/8 po du plafond.
La xation inférieure doit être installée au point inférieur
du manchon de la cheminée supérieure.
Déterminer l’emplacement approprié pour chaque xation
et les installer au mur. S’ASSURER QUE LES FIXATIONS
SONT BIEN INSTALLÉES AU MUR.
5. Déterminer et faire toutes les coupes nécessaires
dans le mur pour les conduits. Installer les conduits
avant la hotte.
6. Déterminer l’emplacement approprié pour le câble
d’alimentation, tel qu’il est indiqué à la FIGURE 6. Utiliser
un foret de 1 1/4 po pour faire un trou et y passer le
câble d’alimentation. Utiliser du calfeutrage pour sceller
tout autour du trou. NE PAS mettre en circuit tant que
l’installation n’est pas complétée.
FIGURE 5
FIGURE 6
min & max hauteurs
de plafond
x = 30 po
min
8 pi
2 1/2 po
max
9 pi
5 7/8 po
x = 28 po
min
8 pi
1/2 po
max
9 pi
3 7/8 po
x = 26 po
min
7 pi
10 1/2 po
max
9 pi
1 7/8 po
x = 24 po
min
7 pi
8 1/2 po
max
8 pi
11 7/8 po
Version 07/11- Page 13
INSTALLATION DE LA HOTTE
1. Retirer l’appareil de la boîte et le déposer sur une surface
plane pour l’assemblage. Couvrir la surface pour éviter tout
dommage. Retirer toutes les pièces incluant les ferrures avant
de jeter la boîte.
2. Retirer les ltres pour la graisse de l’appareil et les mettre de
côté. Retirer les ltres pour la graisse en pressant sur la poignée
à l’avant du ltre, tel qu’il est illustré à la FIGURE 7. Au moment
de les replacer, s’assurer que les ltres soient positionnés
adéquatement, la poignée vers l’avant et visible.
FIGURE 8
FIGURE 9
B
FIGURE 10
FIGURE 11
3. Retirer le couvercle du compartiment de câblage. Retirer la
pastille enfonçable de la boîte électrique à l’aide d’un tournevis
à lame plate. Passer le câble d’alimentation par le trou.
4. Suspendre la hotte aux xations (1 de la FIGURE 8). Il y a
deux trous rectangulaires à l’arrière de la hotte. Les xations
passent au travers de ces trous et la hotte est suspendue aux
collerettes des xations. À cause du poids de la hotte, deux
personnes devraient la soulever n d’éviter toute blessure.
S’assurer que la hotte soit en place sur les xations, de façon
sécuritaire.
5. Mettre la hotte de niveau. La hauteur de la hotte peut être
réglée en tournant les vis (W) tel qu’il est indiqué à la FIGURE
8, de chaque côté du ventilateur.
6. Brancher le câble d’alimentation sur la hotte. Attacher le l
blanc du câble d’alimentation sur le l blanc de la hotte avec
une cosse. Attacher le l noir du câble d’alimentation au l noir
de la hotte avec une cosse. Brancher le l de mise à la terre
vert (jaune et vert) sous la vis de mise à la terre verte.
7. Replacer le couvercle du compartiment de câblage et les
ltres pour la graisse.
8. Pour les installations avec conduits, le REGISTRE (I de
la FIGURE 1) doit être xé à l’ouverture d’évacuation sur le
dessus de la HOTTE. Brancher les conduits et sceller toutes
les connexions avec du ruban à conduit.
INSTALLATIONS SANS CONDUIT
N'utilisez pas le REGISTRE ROND (H de la FIGURE 1) pour les
Installations sans conduit. La section CHEMINÉE SUPÉRIEURE
doit être installée en premier.
Installations sans conduit requièrent le Kit Pour Conversion Du
Conduit. Ce nécessaire comprend un CHEMINÉE INFÉRIEURE
AVEC TROUS D'ECHAPPEMENT D'AIR (A de la FIGURE 9), un
DÉFLECTEUR SANS CONDUIT (C), deux GRILLES (B) pour
couvrir les trous du couvercle de cheminée et deux FILTRES AU
CHARBON (D). Le DÉFLECTEUR SANS CONDUIT doit être
installé avant le couvercle de la CHEMINÉE INFÉRIEURE AVEC
TROUS, comme à la FIGURE 9. Le couvercle de CHEMINÉE
INFÉRIEURE SANS LES TROUS doit être mis de côté (B de
la FIGURE 1) .
Installer les FILTRES AU CHARBON (FIGURE 11) sur les côtés
du ventilateur. Installer les ltres pour la graisse.
Une fois le couvercle de CHEMINÉE INFÉRIEURE AVEC TROUS
installé, les GRILLES sont insérées dans les trous, tel qu’il est
illustré à la B de la FIGURE 10
FIGURE 7
Version 07/11- Page 14
9. La cheminée doit être xée à la hotte. La section CHEMINÉE SUPÉRIEURE (C) doit être installée en premier, puis la section
CHEMINÉE INFÉRIEURE (B) . Les deux sections sont xées de façon sécuritaire au mur sous les FIXATIONS DE CHEMINÉE (H),
tel qu’il est indiqué à la FIGURE 12. Attacher la section CHEMINÉE SUPÉRIEURE avec LES VIS DE CHEMINÉE (J). Attacher
la section CHEMINÉE INFÉRIEURE à la HOTTE (A) avec LES VIS DE CHEMINÉE (J).
FIGURE 13
FIGURE 12
10. Mettre l’alimentation en circuit. Mettre en circuit le ventilateur et la lumière. Si la hotte ne fonctionne pas, vérier si le disjoncteur
n’est pas déclenché ou si le fusible n’est pas grillé. Si l’appareil ne fonctionne toujours pas, débrancher l’alimentation et vérier si
les connexions ont été effectuées correctement.
UTILISATION ET ENTRETIEN
Cette hotte est conçue pour enlever la fumée, les vapeurs de cuisson et les odeurs de la
cuisine.
Pour de meilleurs résultats
Mettre la hotte en circuit avant de commencer la cuisson. Laisser l’appareil fonctionner
quelques minutes après la cuisson pour éliminer la fumée et les odeurs de la cuisine.
Nettoyage
Les ltres à graisse en métal devraient être nettoyés fréquemment dans une solution
d’eau chaude et de détergent ou mettre au lave-vaisselle. Utiliser un nettoyant pour l’acier
inoxydable sur les hottes en acier inoxydable. Ne pas utiliser de produits abrasifs ou de
récurants, car ils peuvent égratigner le ni en acier inoxydable et ils ne devraient pas être
employés pour nettoyer les surfaces de nition.
Remplacement de la lumière halogène
Avant d’essayer de remplacer les ampoules, s’assurer que l’interrupteur soit hors circuit.
Retirer les deux vis (de la FIGURE 14). Retirer l’ampoule et la remplacer par une nouvelle
ampoule.
Une méthode alternative pour substituer les lampes est d'utiliser des 1 1/4"tasses d'aspiration
(de la FIGURE 14). Attachez la tasse d'aspiration à l'ampoule et tirez fermement vers le
bas sur l'ampoule et la substituez avec une nouvelle lampe
FIGURE 14
Version 07/11- Page 15
FABER GARANTIE ET SERVICE (
ÉCONOMISER POUR VOS ENREGISTREMENTS
)
Faber garantit à l’utilisateur-acheteur d’origine que les produits Faber vendus neufs par nous sont sans vice de
matériel et de main-d’oeuvre d’origine pour une période d’un an à partir de la date d’achat. La garantie couvre
la main-d’oeuvre et les pièces de remplacement. An d’obtenir un service sous garantie, communiquer avec le
marchand où la hotte a été achetée ou le distributeur Faber de la région. Si l’on ne peut trouver de distributeur
Faber, communiquer avec nous au (508) 358-5353 an d’obtenir le nom d’un distributeur dans la région.
Les frais suivants ne sont pas couverts par la garantie Faber :
1. Les appels de service pour corriger l’installation de votre hotte de cuisinière, pour vous indiquer
comment utiliser votre hotte de cuisinière, pour remplacer ou réparer les fusibles de votre maison ou
pour corriger votre câblage ou votre système de plomberie.
2. Les appels de service pour remplacer ou réparer les ampoules, les fusibles ou les
ltres de votre hotte de cuisinière.
3. Les réparations lorsque votre hotte de cuisinière a été utilisée plus que la normale,
c'est-à-dire plus que pour une famille par foyer.
4. Les dommages résultant d’un accident, de l’altération, d’une mal utilisation, d’un acte
de Dieu, d’une installation inappropriée, d’une installation non-conforme aux
normes d’électricité ou de plomberie ou d’une utilisation de l’appareil non approuvée par Faber.
5. Les pièces de remplacement ou les frais de main d’œuvre pour les unités
utilisées en dehors du Canada ou des États Unis, incluant toutes hotte de cuisinière
approuvée par Faber non UL ou C-UL.
6. Les réparations dues à des modications non-autorisées sur votre hotte de cuisinière.
7. Les frais de transport de l’appareil pour réparations à distance.
Enregistrez Votre Information Ci-dessous:
Séquentiel #: __________________________
Date d'achat: ______________
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Faber SYNT36SS300 Installation Instructions (PDF)

Catégorie
Hottes
Taper
Installation Instructions (PDF)

dans d''autres langues