SYNAPSE CBSSW-450-002 Central Base Station Guide d'installation

Catégorie
Antennes réseau
Taper
Guide d'installation
DOC-1000598-A-2
SPECIFICATIONS
Dimensions : 12.6” x 10.6” x 7.6(320 x 270 x 193 mm)
Input Power : 110-277VAC, +/- 10%; 11W max; 6kV surge
protection
Operating Temperature : -40°C to +54°C
Radios : SNAP 2.4GHz 802.15.4; Wi-Fi 2.4Ghz 802.11 b/g/n;
Cellular 4G LTE
CAUTION
The Central Base Station must be installed in accordance
with national, state, and local electrical codes and
requirements
All work must be performed by qualified personnel
Disconnect all power before installation or service
Metal conduit and connector must be grounded
NEEDED MATERIALS
Mounting Hardware: Using hardware appropriate for the
installation and mounting surface (0.25” diameter screw or bolt),
use all six (6) 0.310" diameter mounting holes to mount the unit
Screwdriver: A 1/8 Hex screwdriver or Allen key is required to
remove the wiring/bottom compartment cover
Needle-nose Pliers: For tightening antenna cable connections if
external antenna kit is used
Conduit
For indoor installations: 3/4” conduit fitting with a cable
strain relief or cable clamp is needed for indoor
installations. The power entry point is sized for a 3/4”
NPT (1.12” diameter).
For outdoor installations: A liquid rated (IP65/NEMA 4X)
3/4” conduit fitting is needed for outdoor installations.
The power entry point is sized for a 3/4” NPT (1.12”
diameter).
Note: To maintain IP rating of the unit, it must be installed with a
IP65/NEMA 4X fitting at the power and ethernet entry points.
WARNING: TO AVOID FIRE, SHOCK, OR DEATH: TURN OFF
POWER AT CIRCUIT BREAKER OR FUSE AND VERIFY THAT
POWER IS OFF BEFORE WIRING!
INSTALLATION INSTRUCTIONS
WARNING: DO NOT INSTALL THE CENTRAL BASE STATION
IN DIRECT SUNLIGHT. If installing the Central Base Station
outdoors, ensure that the Central Base Station is provided some
means of shading from direct sunlight. Installing the unit in direct
sunlight will substantially reduce maximum operating
temperature. Please install unit in shaded area or provide a non-
metallic sunshade that will not obstruct RF signals.
1. Select an installation location for the Central Base Station.
The best location provides direct line of sight between the
Central Base Station or the optional external antenna and
at least two other lighting controllers in the network. The
antennas inside the Central Base Station rely on free space
around them for best RF performance so avoid an
installation near network cabling, AC power lines or metal
pipes.
2. There are two ways to mount the Central Base Station
(CBS): using a pole strap (step 3) or screwing the CBS to a
wall with the screw holes (step 4).
WARNING: The CBS must be mounted vertically
with the conduit coming out of the bottom of the
unit, or the wireless signals may be compromised.
DO NOT install the CBS horizontally.
3. You can mount the CBS to a pole using any Polycase pole
straps that are compatible with the Polycase© YH-121006
enclosure.
4. Using six (6) 0.25” diameter screws that can fit the 0.310”
diameter mounting holes and capable of supporting 50 lbs.
of weight, screw the CBS to the wall.
5. Remove the two screws and lower cover to access the
bottom wiring compartment. (Figure 1). A flathead
screwdriver may be used to help lift and remove the cover.
6. Once the CBS is mounted and the wiring compartment
cover is removed, you must have a licensed electrician
connect power into the CBS’s wiring compartment
according the national, state, and local electrical codes and
requirements. The three connection points in the wiring
compartment are as follows:
Black is Line
White is Neutral
Green is Ground
NOTE: To ensure safety and surge protection connect
the green ground wire to an earth ground.
7. If you are using an external antenna kit, please refer to the
“INSTRUCTIONS FOR INSTALLING EXTERNAL ANTENNA
KIT OPTIONAL” section in this guide for the necessary
configuration steps.
8. If you are not using an external antenna kit, place the lower
cover back into position and tighten the two screws.
(Figure 1)
NOTE: The Power entry cable is not provided. The power
entry hole is 3/4” knockout (1.12”).
For indoor installations use a proper sized conduit
fitting with a cable strain relief or cable clamp.
For outdoor installations use a proper sized conduit
and a sealed power entry connector in order for the
box to meet NEMA 4X standards.
NOTE: The Central Base Station holds a rating of IP65 for
outdoor when the door is latched, and all entry ports
(power and ethernet) are properly sealed. Failure to
properly seal entry ports and latch the door will void the
IP65 rating.
WARNING: THERE ARE NO SERVICEABLE COMPONENTS
INSIDE THE CENTRAL BASE STATION, except for the
Surge Protection Device which should only be replaced
by a licensed electrician. The Surge Protection Device
replacement part number is LSP10277S.
Operation Instructions for Push Buttons
The default behavior for the 5 buttons are as follows:
1. 100% Light Level (Zone All)
2. 75% Light Level (Zone All)
3. 50% Light Level (Zone All)
4. 25% Light Level (Zone All)
5. Off (Zone All)
NOTE: To program the button for a different behavior please
contact your commissioning agent, refer to any training
material you received, or open a support ticket at-
https://support.synapsewireless.com/
Note: Door image removed for clarity.
INSTRUCTIONS FOR INSTALLING
EXTERNAL ANTENNA KIT - OPTIONAL
The Central Base Station includes an external connector on the
bottom of the unit for use with the Synapse Outdoor Antenna Kit.
This external antenna and cable help ensure that the
SimplySNAP gateway signal is amplified and propagated to
other devices. This is important on large sites or sites with large
physical obstructions between the SimplySNAP gateway and
lighting controllers.
Note: For more Details on outdoor antenna installation
instructions please see the Outdoor Antenna Install Guide
https://help.synapsewireless.com/Lighting/Assets/Hardware_Gui
des/Outdoor Antenna Install Guide.pdf
If you are using an outdoor antenna kit, follow the instructions
below to prepare the Central Base Station for connection using
the external connector on the bottom of the unit.
1. With the lower cover of the wiring compartment removed,
find the cable A and B and connector C as shown below in
the bottom right of the unit. (Figure 2).
2. Unscrew the connectors on cable A and B to
disconnect cable A from cable B.
3. Screw on and hand tighten the connector on cable B
to connector C as shown below. (Figure 3)
4. Tighten a ¼ turn with a pair of needle nose pliers. Do
not over tighten or the RF pin in the bulkhead will
crack, creating poor RF link quality.
5. Place the lower cover back into position and tighten
the two screws. (Figure 1)
6. Connect the external cable and antenna according to
the install guide included with the Outdoor Antenna
Kit.
REGULATORY INFORMATION AND
CERTIFICATIONS
RF Exposure Statement: This equipment complies
with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be
installed and operated with minimum distance of 20cm
between the radiator and your body. This transmitter
must not be co-located or operating in conjunction with
any other antenna or transmitter.
Industry Canada (IC) certifications: This digital
apparatus does not exceed the Class B limits for radio
noise emissions from digital apparatus set out in the
Radio Interference Regulations of the Canadian
Department of Communications.
Le present appareil numerique n’emet pas de bruits
radioelectriques depassant les limites applicable aux
appareils numeriques de la class B prescrites dans le
Reglement sur le brouillage radioelectrique edicte par le
ministere des Communications du Canada.
FCC certifications and regulatory information
(USA only)
FCC Part 15 Class B: This device complies with part
15 of the FCC rules. Operation is subject to the
following two conditions: (1) These devices may not
cause harmful interference, and (2) These devices must
accept any interference received, including interference
that may cause harmful operation.
RADIO FREQUENCY INTERFERENCE (RFI) (FCC
15.105): This equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against
harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there
is no guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful interference to radio or television reception,
which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
(1) Re-orient or relocate the receiving antenna; (2)
Increase the separation between the equipment and
the receiver; (3) Connect the equipment into an outlet
on a circuit different from that to which the receiver is
connected; (4) Consult the dealer or an experienced
radio/TV technician for help.
CERTIFICATIONS
Model : CBSSW-450-002
Contains FCC ID : U9O-SM220
Contains IC : 7084A-SM220
UL File No : E346690
ROHS : 3:2011/65/EU(2015/863)
For Support-
Please contact your commissioning agent or installer,
or open a support ticket at-
https://support.synapsewireless.com/
INSTALLATION GUIDE
WARNING AND CAUTIONS:
TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND
TEST THAT POWER IS OFF BEFORE WIRING!
Risk of Electric Shock - Local codes may require more than one disconnect switch. De-energize
all disconnect switches before servicing the equipment.
Use this device with copper or copper clad wire only.
To be installed and/or used in accordance with appropriate electrical codes and regulations.
If you are unsure about any part of these instructions, consult an electrician.
CBSSW-450-002 Central Base Station
Power Ratings: 110-277VAC; 11W max
Operating Temperature: -40 to +54 C
WARNINGS AND CAUTIONS:
Disconnect power at circuit breaker or fuse when servicing, installing, or removing fixture or
changing lamps.
Mounting: It is critical to the RF performance of this device that the enclosure be oriented
vertically. Enclosure must be mounted with door latch/lock on the right.
Metal conduit and connector must be grounded.
A
B
C
C
C
C
B
A
Figure 1
Figure 3
Figure 2
355.8
14.01
269.1
10.59
336.6
13.25
333.4
13.13
323.9
12.75
6.4
.25
TYP
203.2
8.00
193.7
7.63
7.9
.31
TYP
6.7
.27
TYP
C
L
C
L
Top
Bottom
Note: This drawing
is the rear view of
the CBS and is a 1:1
image if printed on