Mi-Heat MI-HEAT ETM, TS 15 Guide d'installation

Taper
Guide d'installation
ETM, TS
Mi-Heat Heizsysteme GmbH Ol Streek 39a D-26607 Aurich, Germany
Tel.: +49 (0)4941-6971930 Email: info@infrarot-fussboden.de
INHALT
ALLGEMEINE HINWEISE ZUR VERLEGUNG
WÄRMEVERLUSTTABELLE
INSTALLATION AM ROHR
INSTALLATION ALS DACH- UND FALLROHRHEIZUNG
INSTALLATIONSBEISPIELE
TECHNISCHE DATEN
BEANSTANDUNGEN, GARANTIE
GARANTIESCHEIN
2
3
4
4
14
18
19
20
INSTALLATIONSANLEITUNG
CONTENT
GENERAL INFORMATION TO INSTALLATION
HEAT LOSS TABLE
INSTALLATION ON PIPE
INSTALLATION AS ROOF AND DOWNSPOUT HEATING
INSTALLATION EXAMPLES
TECHNICAL DATA
CLAIMS, WARRANTY
GUARANTEE CARD
6
7
8
8
14
18
19
20
INSTALLATION INSTRUCTIONS
CONTENU
INFORMATIONS GÉNÉRALES CONCERNANT
L‘INSTALLATION TABLEAU DES PERTES DE CHALEUR
TUYAU D‘INSTALLATION
INSTALLATION COMME TOIT ET CHAUFFAGE GOULOTTE
DES EXEMPLES D‘INSTALLATION
CHARACTÉRISTIQUES TECHNIQUES
RÉCLAMATIONS, GARANTIE
CERTIFICAT DE GARANTIE
10
11
12
12
14
18
19
20
INSTRUCTIONS D‘INSTALLATION
2
ALLGEMEINE HINWEISE ZUR VERLEGUNG
• Bei der Installation oder dem Arbeiten an dem Heizkreis ist es sicherheitsrelevant, die Stromzufuhr abzustellen.
• Der Abstand zwischen den Heizleitern am Rohr muss mindestens 50mm betragen.
• Der minimale Abstand zum Heizkreis in Dachrinnen sollte 2cm betragen.
• Der minimale Biegeradius darf nicht unterschritten werden.
• Heizleitungen dürfen nicht gekreuzt oder geknickt werden.
• Bitte beachten Sie, dass die Rohrleitungen im Regelbetrieb nicht mehr als 60 °C erreichen.
Es wird empfohlen, die Installation durch eine Elektrofachkra unter sorgfältiger Beachtung national und international gültiger Normen und Standards
ausführen zu lassen.
• Der Einsatz eines Fehlerstromschutzschalters (30 mA) ist bei der Verwendung von Heizkreisen zwingend vorgeschrieben.
• Der Anschluss der Heizelemente darf nur von einem erfahrenen Fachmann, unter Beachtung aller geltenden VDE Bestimmungen, erfolgen.
Die An- und Abschlussmuen müssen sorgfältig behandelt werden. Die Zugbeanspruchung auf die Muen darf die maximal zulässige Belastung von 120 N
nicht überschreiten.
Die Muen dürfen nicht geknickt oder beschädigt werden.
Kürzen oder verlängern des Heizkreises ist strengstens untersagt.
Önen oder ersetzen Sie die ursprüngliche Verbindung nicht. Um den Kaltleiter zu verlängern wird empfohlen, eine Anschlussdose zu nutzen.
• Heizkreise dürfen niemals in aufgerolltem Zustand in Betrieb genommen werden.
Das gelb-grüne Kabel (Erdungskabel) muss dauerha und zuverlässig an eine Erdungsmaßnahme (PE-Leiter) angeschlossen werden.
• Stellen Sie sicher, dass alle mechanischen Rohrprüfungen (d.h. hydrostatische Prüfung / Spülung) abgeschlossen sind.
• Planen Sie die Verlegung der Heizleitung am Rohr.
• Das Vorhandensein der Heizkreise muss ersichtlich gemacht werden, z.B. durch die Anbringung von Warnzeichen im Sicherungskasten oder
Kennzeichnungen vor Ort.
• Des Weiteren müssen sie Teil einer elektrischen Dokumentation entlang der Installation sein.
Beim Verlegen und Ziehen der Heizbänder sind scharfe Kanten und Schweißperlen sowie hohe Zugkra zu vermeiden.
Heizkreise dürfen nie direkt auf Kunststorohren bzw. Kunststoteilen montiert werden. Kunststoteile und -rohre müssen unbedingt zu 100% mit
Alufolie abgedeckt werden.
Bitte installieren Sie das Heizelement streng nach den Schaltplänen.
• Bei Installation oder Gebrauch darf das Heizkabel keinen Biegungen ausgesetzt sein, welche die Werte in den technischen Daten überschreiten.
Verwenden Sie Ihr Heizsystem niemals, wenn Ihnen eine Beschädigung bekannt ist.
Das Heizsystem darf keinen mechanischen Belastungen, Spannungen und längsverlaufenden Biegungen während der Installation oder beim Gebrauch
ausgesetzt sein.
• Es ist verboten, alternative Konstruktionen an den Heizelementen vorzunehmen, welche nicht in der Anleitung beschrieben wurden.
Es ist untersagt, den Heizkreis an eine andere Spannung als 230±10 VAC anzuschließen.
Es ist verboten, Heizkabel ohne Außenmantel in Klebstoschichten oder in Straßenbelag zu verwenden.
Um Beschädigungen am Heizelement zu vermeiden, muss zwingend darauf geachtet werden, dass nach der Installation in diesem Bereich keine
nachträglichen Bauarbeiten, wie z.B. Bohren oder Sägen, mehr stattnden.
Während der Installation sollte der Kontakt des Heizkabels mit Öl, Lösungsmitteln oder ähnlichen Substanzen vermieden werden.
Um eine Überlastung des Stromnetzes zu verhindern, sollte die Stromversorgung des Heizkabels die maximale Spannung nicht überschreiten.
Die beheizte Fläche muss vollständig eben und frei von Steinen oder anderen spitzen Gegenständen sein. Falls erforderlich, verlegen Sie bitte einen
Kantenschutz an den Übergangspunkten Ihrer Dachrinne oder Ihres Fallrohrs.
• Beginnen Sie mit der Verlegung des Heizkabels an der Anschlussdose.
• Die Fertigstellung der An-und Abschlüsse dürfen nur unter trockenen Bedingungen ausgeführt werden.
Ein Rohrleitungsheizsystem kompensiert den Wärmeverlust, der trotz Isolierung unvermeidbar ist. Durch die Wärmekompensation, ermöglicht die
Rohrheizung, dass der Inhalt des Rohres auf der gewünschten Temperatur gehalten werden kann. Durch Beheizen der Rohre oder Dachrinnen werden
folgende Schäden vermieden:
das Platzen der Rohre durch Einfrieren
das Einfrieren von Flüssigkeiten im Inneren
das Verstopfen der Rohrleitungen und Dachrinnen
WICHTIGER HINWEIS: Bitte lesen Sie diese Anleitung sorgfältig durch, bevor Sie mit der Installation des Produktes beginnen. Die Zuverlässigkeit
Ihres Heizsystems hängt sehr stark davon ab, wie sorgfältig Sie Ihr Heizsystem installieren. Die Inhalte dieser Betriebsanleitung wurden für Personen
beschrieben, die sich mit dem Sachverhalt von elektrischen Begleitheizungen auskennen.
Überprüfen Sie die Beschaenheit des Heizkabels. Der Außenmantel des Heizkabels darf nicht beschädigt sein oder werden.
Überprüfen Sie das System (Leistungsabgabe, Abschnittslänge).
Es wird empfohlen, vor Installationsbeginn folgende Vorbereitungen zu treen:
Fertigen Sie einen Verlegeplan der Heizelemente an.
Legen Sie die Position des Temperatursensors fest.
Legen Sie die Position und Größe des Schaltschrankes fest.
Legen Sie sich die notwendigen Werkzeuge und Materialien für die Installation bereit.
Entscheiden Sie sich für ein geeignetes Verfahren zur Befestigung der Heizleitungen an der Oberäche Ihres Rohres, Daches, der Dachrinne
oder des Fallrohrs.
Befreien Sie Ihr Rohr, Dach, Dachrinne oder Fallrohr von Blättern und sonstigem Schmutz.
VORBEHALT
Wir behalten uns vor, technische Daten jederzeit und ohne Ankündigung zu ändern. Änderungen, Irrtümer und Druckfehler begründen keinen Anspruch
auf Schadensersatz. Um Ihre Sicherheit zu gewährleisten, müssen zwingend die entsprechenden Richtlinien und Vorschrien, sowie die Betriebs- und
Installationsanleitung beachtet werden.
5 mm 10 mm 15 mm 20 mm 30 mm
6 mm
8 mm
10 mm
15 mm
22 mm
28 mm
35 mm
42 mm
54 mm
3
3
3
4
5
6
7
7
9
0,035 W/mk
W/m @ -20°C
7
8
10
13
18
22
26
31
39
4
5
6
8
10
12
15
17
21
4
4
5
6
8
9
11
12
15
3
4
4
5
6
7
9
10
12
5 mm 10 mm 15 mm 20 mm 30 mm
6 mm
8 mm
10 mm
15 mm
22 mm
28 mm
35 mm
42 mm
54 mm
3
4
4
5
5
6
7
7
8
0,042 W/mk
W/m @ -20°C
8
10
11
15
21
26
32
37
47
6
6
7
8
10
12
14
16
19
5
5
6
7
8
9
10
12
14
4
4
5
6
7
8
9
10
11
5 mm 10 mm 15 mm 20 mm 30 mm
6 mm
8 mm
10 mm
15 mm
22 mm
28 mm
35 mm
42 mm
54 mm
2
2
3
3
4
4
4
5
6
0,035 W/mk
W/m @ -20°C
5
6
7
9
13
15
19
22
28
4
4
5
6
7
8
10
11
13
3
3
4
4
5
6
7
8
9
3
3
3
4
4
5
6
6
8
3
MINERALWOLLE
WÄRMEVERLUSTTABELLE
Diese Betriebsanleitung ist nicht dafür bestimmt, Ihnen die Grundlagen der Wärmeverlustberechnung zu vermitteln. Bitte wenden Sie sich an ihren
Fachhändler, falls Sie eine Wärmverlustberechnung benötigen.
Man spricht von einem Wärmeverlust, wenn die Umgebungstemperatur geringer als die Temperatur des Rohres ist. Es ndet ein permanenter
Temperaturwechsel statt (von warm zu kalt). Dies kann im ungünstigsten Fall dazu führen, dass Ihre Rohrleitung einfriert. Die Heizkreise halten Ihre
Rohrleitungen bis zu einer Umgebungstemperatur von -20°C zuverlässig frostfrei.
Die folgenden Tabellen sollen Ihnen bei der Auswahl der richtigen Heizleistungen helfen. Die dort dargestellten Wärmeverluste sind bei einer
Umgebungstemperatur von -20°C ermittelt worden. Bitte verlegen Sie die im Folgenden beschriebenen Heizkabel nur an Rohrleitungen.
Wenn die Leistung eines Heizkreises nicht ausreicht, müssen Sie die Anzahl der Heizkreise erhöhen um die nötige Leistung zu erreichen. Bitte beachten
Sie, dass die in der Tabelle angegebenen Werte nur Richtwerte sind und Ihnen lediglich als Orientierung dienen sollen. Die Isolationswerte sind nur
Durchschnittswerte, welche bei den unterschiedlichen Herstellern abweichen können. Die Maßeinheit für den Wärmeverlust ist W/m.
Zum Beispiel:
Die benötigte Heizleistung für ein Rohr mit 42mm Durchmesser und 5mm Mineralwolle Isolierung bei -20°C Umgebungstemperatur beträgt 31 W/m.
Dies würde bei diesem Beispiel bedeuten, dass es empfehlenswert ist, zwei Heizkabel auf der Rohrleitung zu montieren.
ARMAFLEX
PU-SCHAUM
1
2
3
4
.
30 W/m
30 W/m
250 W/m²
40 W/m
40 W/m
300 W/m²
4
INSTALLATION AM ROHR
Materialien überprüfen:
Prüfen Sie, ob alle in der Anleitung beschriebenen Teile im Lieferumfang enthalten sind.
Stellen Sie sicher, dass die zur Verfügung stehende Betriebsspannung mit der Nennspannung des Heizkreises übereinstimmt.
Überprüfen Sie das Heizkabel und alle Komponenten auf Transportschäden. Prüfen Sie das Heizkabel zudem auf Schäden im Außenmantel.
Beschädigte Heizkabel dürfen aus sicherheitsrelevanten Gründen niemals verwendet werden.
Rohrleitungen überprüfen:
Überprüfen Sie die Rohrleitungen auf Schweißperlen, raue Oberächen oder scharfe Kanten. Entfernen Sie diese gegebenenfalls.
Stellen Sie sicher, dass alle Rohroberächen berührungstrocken sind.
AUSROLLEN
ABKLEBEN
BEFESTIGEN
ISOLIEREN
Rollen Sie den Heizkreis aus.
Vermeiden Sie Schlaufen
und knicken Sie die
Heizleitung nicht.
Bringen Sie das Heizkabel
entsprechend der
Rohrstärke und der
erforderlichen Heizleistung
ein- oder mehrfach der
Länge nach am Rohr an und
befestigen Sie es im Abstand
von 30cm.
Überkleben Sie
das Heizkabel mit
Aluminiumklebeband, um
die Wärmeverteilung zu
verbessern.
Nach Montage des
Heizkabels sind die Rohre
mit handelsüblichem
Isoliermaterial zu versehen.
INSTALLATION ALS DACH- UND FALLROHRHEIZUNG
WÄRMEVERLUSTTABELLE
Es ist wichtig, dass Sie die örtlichen Bedingungen, sowie Ihre Dachkonstruktion bei der Auswahl Ihres Heizsystems berücksichtigen.
In der Regel werden die Dachtypen in die zwei folgenden Kategorien eingeteilt:
Kaltdach: Diese Dachkonstruktion ist sehr gut isoliert.
Warmdach: Diese Dachkonstruktion ist sehr schlecht isoliert.
Es ist im Normalfall immer mit den Bedingungen eines „Kaltdachs“ zu rechnen.
Für die Auswahl der optimalen Dachrinnenheizung sollten Sie folgende Werte berücksichtigen:
Falls Sie größere Rinnenquerschnitte besitzen, sollten Sie die Anzahl der Heizbänder mit den in der folgenden Tabelle dargestellten Multiplikatoren
erhöhen.
Kaltdach-Konguration
Rinne <201mm* :
Fallrohr <201mm* :
Kehle:
Warmdach-Konguration
Rinne <201mm* :
Fallrohr <201mm* :
Kehle:
* Rinnenquerschnitt
d
d
1
2
34
6
5
7
811
12
10
7
9
5
Rinnenquerschnitt
(mm)
200
250
280
333
400
500
Halbrund
(d)
80 mm
105 mm
127 mm
153 mm
192 mm
250 mm
Kastenförmig
(d)
70 mm
85 mm
120 mm
150 mm
200 mm
Konguration
Multiplikator
1
2
2
2
3
3
Beispiel: Bei halbkreisförmigen Dachrinnen mit einem Rinnenquerschnitt von 250 bis 333mm ist es
notwendig, zwei Lagen des Heizkabels zu verlegen.
DACHRINNEN
Bitte befestigen Sie die Kabelhalterungen an der Dachrinne.
Der Abstand zwischen den Kabelhalterungen sollte 0,25 m bei einlagiger Verlegung und 0,5 m bei
mehrlagiger Verlegung betragen. Das Heizkabel sollte auf dem Boden der kastenförmigen Dachrinne
verlegt werden.
FALLROHRE
Bei Fallrohren sollten Sie bis zu einem Durchmesser von 100 mm nur eine Lage des Heizkabels
verwenden. Bei einem Durchmesser von über 100 mm, sollten Sie die Anzahl der benötigten Heizkabel
mit dem in der Tabelle dargestellten Multiplikator erhöhen.
ACHTUNG: Bitte rechnen Sie damit, dass bei nicht vorkonfektionierten Heizkabeln (Meterware) 1 m
mehr Heizkabel für den An- und Endabschluss benötigt wird.
Fallrohr-Durchmesser
(mm)
50
60
76 und 80
87
100
120
150
Konguration
Multiplikator
1
1
1
1
1
2
2
Falls Sie nur eine Lage des Heizkabels verwenden und Ihr Fallrohr unterirdisch verläu, ist es empfehlenswert, das Heizkabel zu schleifen. Verlegen Sie das
Heizkabel bis zu 80 cm unter der Erde (Frostgrenze) oder bis Ihr Fallrohr in das Abwassernetz eintritt. Bei der Verlegung von Fallrohren, die unterirdisch
verlaufen, benötigen Sie zusätzlich 2 m Heizkabel. Die Montage der Heizkabel in Fallrohren mit weniger als 10 m Länge kann ohne die Verwendung von
Tragseilen erfolgen.
Befestigen Sie die Seilklemmen am Heizkreis. Die Klemmen sollten in einem Abstand von 250-400 mm befestig werden. Um an den Stellen, an denen sich die
Metallbefestigungen der Klemmen benden, Schäden am Heizkabel zu vermeiden, wickeln Sie bitte 2-3 Schichten Glasseidenklebeband um diese Stellen.
Befestigen Sie den Heizkreis auf Ihrem Objekt.
Bei Fallrohren mit einem Durchmesser von mehr als 100 mm sind zwei Lagen Heizkabel notwendig. Bei Kupfer-Fallrohren muss ein Stahlseil mit einem
Polyethylen-Mantel verwendet werden. Die Befestigung der Heizleitung auf dem Seil:
Befestigen Sie das Heizkabel mit Hilfe von Klammern alle 1,5 m am Seil.
Verlegen Sie nun das vorbereitete Heizkabel im Fallrohr.
Schützen Sie das Heizkabel vor scharfen Kanten.
Wir empfehlen Ihnen, ein Gewicht (max. 1 kg) am Ende des Seils zu befestigen, um eine Verdrehung des Seils zu vermeiden.
KEHLE UND GAUBE
Befestigen Sie das Blech auf der Kehle bzw. Gaube.
Der Abstand zwischen den Kabelhalterungen sollte 0,25 m bei einlagiger Verlegung und 0,5 m bei mehrlagiger Verlegung betragen.
TRAUFBLECH
Traufbleche sind der Übergang zwischen der Dachäche und der Regenrinne und schützten die Unterkonstruktion vor Eindringen von Feuchtigkeit.
Befestigen Sie die Halterung auf dem Traufblech.
Der Abstand zwischen den Kabelhalterungen sollte 0,25 m bei einlagiger Verlegung und 0,5 m bei mehrlagiger Verlegung betragen.
Das Heizkabel sollte auf dem Unterteil des Traufblechs verlegt werden.
1-Fallrohre
2-Dachgaube
3-Hängerinnen
4-Flachdachentwässerung
5-Dachentwässerung
6-Dachkehle
7-Dachentwässerung
8-Schneefangsysteme
9-Traufblech
10-Flachdach
11/12-Flachdachablauf
6
GENERAL INFORMATION TO INSTALLATION
• Please shut down the system and ensure that energizing is impossible, before starting installation or maintenance.
• The distance between the heating cables on a pipe must be at least 50mm.
• The minimum distance to heating circuits in gutters is 2cm.
• The installation cannot be under the mimimum bending radius.
• Heating cables cannot be crossed or folded.
• Please pay attention that pipelines in operation do not reach over 60 °C.
It is recommended to have the installation done by an electrically qualied person in accordance with the latest local and international regulations and
standards.
The application of a fault-current circuit breaker (30 mA) with the use of heating circuits is required by law.
The termination of heating elements may only be done by an experienced professional, according to valid VDE Regulations.
The power connection and end connection termination must be handled cautiously. The allowed pull stress of the terminations cannot exceed 120 N.
• The connetions cannot be folded or damaged.
It is not allowed to shorten or extend the heating circuit.
Do not open or replace the original termination. We recommend to use a termination box when extending the cold lead length.
• Heating circuits cannot be energized while rolled together.
• The green/yellow cable (earthing cable) must be permanentely connected to a reliable earthing (PE-wire).
• Ensure that all mechanical pipe tests (i.e. hydrolic testing / cleaning) have been completed.
• Plan the installation of the pipe heating section.
Make the presence of the heating circuit visable, i.e. by placement of warning labels or marking in place, for example on circuit breaker cabinets.
• Furthermore, they need to be part of the electrical documentation along the installation.
• Sharp edges, burrs, and too high pulling forces are to be avoided during installation and pulling of the heating cables.
Heating sections are not allowed to be directly installed onto plastic pipes or plastic parts. First the plastic object must absolutely be 100% covered with
aluminum foil.
• Please install the heating section stricktly according to the wiring diagrams.
• By installation or usage, the heating cable bends cannot be installed or operated under the values stated in the technical data.
• Never use your heating sytsem when there is a known damage.
The heating system cannot be exposed to mechanical loads, operation voltage and long running bends during the installation or operation.
• It is forbidden to make alternative constructions on the heating elements that are not written in the instructions.
• It is forbidden to use the heating section on a voltage other than 230±10 VAC.
• It is forbidden to use a heating cable without overjacket, in glue layers or under a road surface.
It is compulsory to be made attention that aer installation of the heating section, there is no construction work, such as drilling or sawing, being done in
the installation area.
• Contact of the heating cable with oil, disolvents, or other solutions shall be avoided during the installation.
The heating cable should not be over the maximum allowed power supply, in order to prevent overlasting of the electrical network.
• The heated area must be fully even and free from stones and other pointed objects. Please use edge protection on the transition points of the gutters and
downspouts if necessary.
Begin installation of the heating section at the termination box.
• The completion of the power and end connections can only be done under dry conditions.
A pipe heating system uses the electric heater cable to compensate the heat that is lost through the thermal insulation. Replacing the lost heat allows the
pipe and uid inside the pipe to be maintained at a desired temperature.
Heating of pipes or gutters can prevent the following damages:
Bursting of pipes due to frost
Freezing of liquids inside
Cloging of pipes and gutters
IMPORTANT NOTES: Please read this manual carefully, before proceeding with installation. The system reliability and the eective operation are highly
dependent upon its installation quality. The contents of this manual are intended mainly for persons who are familiar with the installation, the operation
and the maintenance of electric trace heating systems.
Check the heating cable characteristics. The overjacket of the heating section cannot be damaged.
Check the system (performance, section lengths).
The following preparation are recommended to be met before installation begins:
Dra an installation plan of the heating elements.
Determine the temperature sensor positions.
Determine the position and size of the electrical power cabinet.
Make the necessary tools and materials for installation available.
Decide an appropriate method for securing the heating section onto the pipe, roof, gutter, or downspout.
Free the pipe, roof, gutter, or downspout from leaves and other dirt
RESERVATION
Technical data are subject to change without notice. Changes, errors and printer‘s errors do not justify claims for damages. For safety components and
systems the relevant standards and regulations are to be observed, as well as the corresponding operating and installation instructions.
5 mm 10 mm 15 mm 20 mm 30 mm
6 mm
8 mm
10 mm
15 mm
22 mm
28 mm
35 mm
42 mm
54 mm
3
3
3
4
5
6
7
7
9
0,035 W/mk
W/m @ -20°C
7
8
10
13
18
22
26
31
39
4
5
6
8
10
12
15
17
21
4
4
5
6
8
9
11
12
15
3
4
4
5
6
7
9
10
12
5 mm 10 mm 15 mm 20 mm 30 mm
6 mm
8 mm
10 mm
15 mm
22 mm
28 mm
35 mm
42 mm
54 mm
3
4
4
5
5
6
7
7
8
0,042 W/mk
W/m @ -20°C
8
10
11
15
21
26
32
37
47
6
6
7
8
10
12
14
16
19
5
5
6
7
8
9
10
12
14
4
4
5
6
7
8
9
10
11
5 mm 10 mm 15 mm 20 mm 30 mm
6 mm
8 mm
10 mm
15 mm
22 mm
28 mm
35 mm
42 mm
54 mm
2
2
3
3
4
4
4
5
6
0,035 W/mk
W/m @ -20°C
5
6
7
9
13
15
19
22
28
4
4
5
6
7
8
10
11
13
3
3
4
4
5
6
7
8
9
3
3
3
4
4
5
6
6
8
7
HEAT LOSS TABLE
This manual is not intended to cover the fundamentals of heat loss calculation. Please contact your supplier if a heat loss calculation is required.
Heat loss is when the ambient temperature is lower than that pipe maintenance temperature. There is a constant temperature change between warm and
cold, that can, in the most unfortunate situation,cause your pipes to freeze. The heating circuits dependently maintain your pipe frost free by temperatures
below to -20°C.
The following charts/ tables are intended to make it easier for you to choose the right heating power. The heating losses shown in this charts were
established for an ambient temperature of -20°C. Please install the heating cables only alongside the pipe.
In case the power of a heating cable is not suicient, we kindly ask you to increase the number of layers. Please pay attention to the fact that the shown
values are approximate values only and are intended as a selection help only. The insulation values are average values only which may dier with dierent
manufacturers. The measuring unit for the heat loss is W/m.
For example:
The normal needed power output for a 42mm pipe diameter with 5mm Mineral Wool insulation is 31 W/m at -20°C ambient temperature.
This means that the heating cable will need to be installed twice onto the pipe according to this example.
MINERAL WOOL
PU FOAM
ARMAFLEX
8
1
2
3
4
.
30 W/m
30 W/m
250 W/m²
40 W/m
40 W/m
300 W/m²
INSTALLATION ON PIPE
Check the materials:
Ensure that everything in the installation manual described parts are in the delivery.
Ensure that the available operation voltage and the operation voltage of the heating cable are the same.
Check the heating cable and all components for transportation damages. Check the heating cable additionally for damages to the overjacket.
Damaged heating cables cannot be used due to safety relevant reasons.
Check the pipe:
Check the pipe for welding perls, uneven surfaces or sharp edges. Remove these when found.
Ensure that all pipe surfaces are dry to the touch.
Roll out the heating circuit.
Please avoid loops and do
not bend the heating circuit.
Install the heating circuit
(depending on the thickness
of the pipe and the required
heating power) alongside
the pipe – in single or
multiplicate and x it every
30cm.
Wrap the heating circuit
with aluminium adhesive
tape or aluminium foil in
order to improve the heat
distribution.
Aer installation of the
heating circuit, the pipes
have to be wrapped
with standard insulation
material.
ROLL OUT INSTALLATION
COVERING INSULATION
INSTALLATION AS ROOF AND DOWNSPOUT HEATING
CALCULATION AND SELECTION
It is important to consider the local conditions and type of roof construction by the selection. Roof constructions are generally categorized into the
following two groups:
Cold roof: this roof construction is very good insulated.
Hot roof: this roof construction is very poorly insulated.
Normally, you shall always calculate with the „cold roof“ - conditions.
For the optimum selection of the correct heating system, the following values are to be taken into account:
Cold Roof Conguration
Gutter <201mm* :
Downspout <201mm* :
Valley gutter:
Hot Roof Conguration
Gutter <201mm* :
Downspout <201mm* :
Valley gutter:
* Nominal dimension
For larger sizes, you should increase the heating tape layer with the conguration multiplier shown in the table below.
d
d
1
2
34
6
5
7
811
12
10
7
9
9
Nominal dimension
(mm)
200
250
280
333
400
500
Semi-circular gutter
(d)
80 mm
105 mm
127 mm
153 mm
192 mm
250 mm
Box gutter
(d)
70 mm
85 mm
120 mm
150 mm
200 mm
Conguration
Multiplier
1
2
2
2
3
3
Downsput diameter
(mm)
50
60
76 and 80
87
100
120
150
Conguration
Multiplier
1
1
1
1
1
2
2
Example: By semi-circular gutters with nominal dimensions of 250 to 333 mm, it is necessary to install
two tracings of heating cable.
GUTTERS
Please install the cable attachments to the gutter.
The distance between the cable attachments should be 0.25 m by one layer tracing and 0.5 m by
multiple layer tracings. The heating cable should be installed onto the oor of box gutters.
DOWNSPUTS
Only one layer of heating cable is requrired by downspouts upt to a diameter of 100 mm. For
downspouts with a diameter over 100 mm, the amount of heat cable tracings should be multiplied by
the amount listed in the table.
ATTENTION: Please take 1m additional cable into account for the power and end termination by
heating cables that are not factory terminated.
It is recommended that the heating cable loop when only one heating cable is used and your downspout runs under the ground level. Install the heating
cable up to 80 cm under the ground level (frost limit) or until the downspout enters with the sewage network. An additional 2 m heating cable is required by
downspouts that run under the ground level. Heating cable may be installed without tension rope in downspouts under 10 m length.
Secure the clamps onto the heating cable. The clamps should be secured with a distance of 250-400 mm. For prevention of damage to the heating cable, 2-3
layers of glass cloth tape should be wrapped around the cable on areas where the clamps are secured. Install the heating circuit to your object.
Two layers of heat tracing are required for downspouts with a diameter of more than 100 mm. A metal rope with polyethylen insulation is necessary for copper
downspouts. Securing of the heating cable onto the tension rope is done as follows:
Secure the heating cable every 1.5 m onto the rope using clamps.
Install the prepared heating cable into the downspout.
Protect the heating cable from sharp edges.
We suggest to use a weight (max. 1 kg) at the end of the tension rope to prevent twisting of the rope.
VALLEYS AND DORMERS
Install the clamps to the valley and dormer sheet metal.
The distance between the clamps should be 0.25 m for one layer heat tracing and 0.5 m for more layer heat tracing.
EAVE FLASHING
Eave ashings are the transitions between the roof areas and the gutters. These protect the underconstruction from moisture going inside.
Install the clamps to the sheet metal.
The distance between the clamps should be 0.25 m for one layer heat tracing and 0.5 m for more layer heat tracing.
The heating cable should be installed on the lower part of the eave ashing.
1-Downspouts
2-Dormers
3-Gutter
4-Downspout entry
5-Splash back
6-Valley
7-Splash back
8-Rake
9-Eave ashing
10-Flat roof
11/12-Roof drain heated area
10
INFORMATIONS GENERALES POUR L‘INSTALLATION
Un système de chauage utilise le câble du radiateur électrique pour compenser la chaleur qui est perdue par l‘isolation thermique. Le remplacement de la
chaleur permet au tuyau et d‘un uide à l‘intérieur du tuyau d‘être entretenus à la température désirée. Le chauage des tuyaux ou des gouttières peuvent
empêcher les dommages suivants :
L‘éclatement des tuyaux dus au givre
Congélation du uide à l‘intérieur
Colmatage des tuyaux et des gouttières
NOTES IMPORTANTES : Veuillez lire attentivement ce manuel avant de procéder à l‘installation. La abilité du système et le bon fonctionnement sont
fortement dépendants de la qualité de son installation. Le contenu de ce manuel est destiné principalement aux personnes qui sont familières avec
l‘installation, l‘exploitation et de maintenance des systèmes de chauage par traçage électrique.
Veuillez arrêter le système et vous assurer que ce qui stimule est impossible, avant de commencer l‘installation ou de l‘entretien.
La distance entre les câbles chauants sur un tuyau doit être au moins 50 mm.
La distance minimale pour les circuits de chauage dans les caniveaux est de 2 cm.
L‘installation ne peut pas être en dessous du rayon de cintrage minimum.
Les câbles de chauage ne peuvent pas être franchis ou pliés.
Veuillez faire attention que les pipelines en exploitation n‘atteignent pas plus de 60 °C.
Il est recommandé d‘avoir l‘installation eectuée par une personne qualiée électriquement en conformité avec les derniers règlements et normes locaux
et internationaux.
L‘application d‘un coupe-circuit à courant de défaut (disjoncteur 30 mA) avec l‘utilisation des circuits de chauage est requise par la loi.
La résiliation des éléments de chauage peut uniquement être eectuée par un professionnel, selon les règlements VDE valides.
La connexion d‘alimentation et de n de la connexion de la résiliation doit être manipulée avec précaution. Le stress de traction permis ne peut pas
dépasser 120 N.
Les connexions ne peuvent pas être pliées ou endommagées.
Il n‘est pas autorisé de prolonger ou raccourcir le circuit de chauage.
Ne pas ouvrir ou remplacer la résiliation originale. Nous vous recommandons d‘utiliser une boîte de résiliation lors de l‘extension de la longueur du l
froid.
Les circuits de chauage ne peuvent pas être sous tension pendant qu‘ils soient roulés ensemble.
Le câble vert / jaune (terre) doit être connecté à un câble de terre able en permanence (PE-wire).
Assurez-vous que tous les tuyaux (par exemple : des tests mécaniques / le nettoyage) ont été achevés.
Planier l‘installation de la section du tuyau de chauage.
Assurez que la présence du circuit de chauage soit visible, c‘est-à-dire par le placement d‘étiquettes d‘avertissement ou le marquage en place, par
exemple sur des armoires coupe-circuit.
En outre, ils doivent faire partie de la documentation électrique le long de l‘installation.
Les arêtes vives, de bavures et de forces de traction trop élevées sont à éviter lors de l‘installation et en tirant des câbles de chauage.
Les sections de chauage ne sont pas autorisées à être directement installées sur les tuyaux en plastique ou des pièces en plastique. Le premier objet en
plastique doit absolument être 100 % couvert de papier aluminium.
Veuillez installer la section de chauage strictement selon les schémas de câblage.
Par l‘installation ou d‘utilisation, la courbe du câble de chauage ne peut pas être installée ou utilisée dans les valeurs indiquées dans les données
techniques.
N‘utilisez jamais votre système de chauage lorsqu‘il y a un dommage.
Le système de chauage ne peut pas être exposé à des charges mécaniques, tension de fonctionnement et courbes longes pendant l‘installation ou
l‘exploitation.
Il est interdit de faire des constructions alternatives sur les éléments de chauage qui ne sont pas décrites dans les instructions.
Il est interdit d‘utiliser la section de chauage sur une tension autre que 230±10 VCA.
Il est interdit d‘utiliser un câble chauant sans enveloppe, avec des couches de colle ou sous une surface de route.
Il est obligatoire d‘attirer l‘attention sur le fait qu‘après l‘installation de la section de chauage, il n‘y a pas de travaux de construction, tels que le forage
ou le sciage, eectués dans la zone d‘installation.
Le câble ne doit pas être en contact avec de l‘huile, solvants ou d‘autres solutions pendant l‘installation.
Le câble chauant ne doit pas dépasser l‘alimentation maximale permise, an d‘éviter un échelonnement du réseau électrique.
La zone chauée doit être entièrement uniforme et libre des pierres et d‘autres objets pointus. Veuillez utiliser la protection sur les points de transition
des gouttières et goulottes si nécessaire.
Commencez l‘installation de la section de chauage à la boîte de cessation.
L‘achèvement de l‘alimentation et des connexions de bout peut seulement être fait dans des conditions sèches.
RÉSERVATION
Les données techniques sont sujettes à changement sans préavis. Changements, erreurs et des erreurs d‘impression ne justient pas de demandes en
dommages-intérêts. Les normes et règlements appropriés doivent être observés pour les pièces de sécurité et les systèmes, ainsi que les instructions
d‘opération et d‘instruction correspondantes.
Vérier les caractéristiques du câble chauant. L‘enveloppe du câble chauant ne peut pas être endommagée.
Vériez le système (performance, section des longueurs).
La préparation suivante est recommandée d’être achevée avant que l‘installation commence :
Rédigez un plan d‘installation des d‘éléments de chauage.
Déterminez les positions du capteur de température.
Déterminez la position et la taille de l‘armoire électrique.
Assurez-vous que les outils et matériaux d‘installation sont disponibles.
Décidez-vous d‘une méthode appropriée pour sécuriser la section de chauage sur le tuyau, la toiture, la gouttière ou la goulotte.
Libérez le tuyau, la toiture, la gouttière ou la goulotte des feuilles et d‘autres saletés.
5 mm 10 mm 15 mm 20 mm 30 mm
6 mm
8 mm
10 mm
15 mm
22 mm
28 mm
35 mm
42 mm
54 mm
3
3
3
4
5
6
7
7
9
0,035 W/mk
W/m @ -20°C
7
8
10
13
18
22
26
31
39
4
5
6
8
10
12
15
17
21
4
4
5
6
8
9
11
12
15
3
4
4
5
6
7
9
10
12
5 mm 10 mm 15 mm 20 mm 30 mm
6 mm
8 mm
10 mm
15 mm
22 mm
28 mm
35 mm
42 mm
54 mm
3
4
4
5
5
6
7
7
8
0,042 W/mk
W/m @ -20°C
8
10
11
15
21
26
32
37
47
6
6
7
8
10
12
14
16
19
5
5
6
7
8
9
10
12
14
4
4
5
6
7
8
9
10
11
5 mm 10 mm 15 mm 20 mm 30 mm
6 mm
8 mm
10 mm
15 mm
22 mm
28 mm
35 mm
42 mm
54 mm
2
2
3
3
4
4
4
5
6
0,035 W/mk
W/m @ -20°C
5
6
7
9
13
15
19
22
28
4
4
5
6
7
8
10
11
13
3
3
4
4
5
6
7
8
9
3
3
3
4
4
5
6
6
8
11
TABLEAU DES PERTES DE CHALEUR
Ce manuel n‘a pas l‘intention de couvrir les fondements du calcul de la perte de chaleur. Veuillez contacter votre fournisseur si un calcul de perte de chaleur
est nécessaire.
La perte de chaleur est lorsque la température ambiante est inférieure à la température de l‘entretien du tuyau. Il y a un changement de température
constante entre l‘air chaud et froid, qui peuvent, dans la plupart des situation regrettables, geler vos tuyaux. Les circuits de chauage maintiennent en
permanence votre tuyau sans givre par des températures inférieures à -20°C.
Les tableaux suivants sont destinés à rendre plus facile votre choix de puissance de chauage. Les pertes de chauage indiquées dans ce tableau ont été
établies pour une température ambiante de -20°C. Veuillez uniquement installer les câbles à côté des tuyaux.
Au cas où la puissance d‘un câble chauant n‘est pas suisante, nous vous demandons d‘augmenter le nombre de couches. Veuillez prêter attention au
fait que les valeurs indiquées sont des valeurs approximatives et ne visent qu‘une sélection de l‘aide seulement. Les valeurs d‘isolement sont des valeurs
moyennes qui peuvent diérer avec des fournisseurs / fabricants diérents. L‘unité de mesure pour la perte de chaleur est W/m.
Par exemple :
La puissance de sortie normale nécessaire pour un tuyau de 42mm de diamètre avec 5mm d‘isolation de Laine Minerale est 31 W/m à une température
ambiante de -20°C.
Cela signierait pour cet exemple qu’il est recommandé de monter deux câbles chauants sur la conduite.
LAINE MINERALE
MOUSSE PU
ARMAFLEX
1
2
3
4
.
30 W/m
30 W/m
250 W/m²
40 W/m
40 W/m
300 W/m²
12
TUYAU D‘INSTALLATION
Vérier le matériel :
Assurez-vous que tout dans la partie des pièces décrites du manuel d‘installation est présent dans la livraison.
Assurez-vous que la tension d‘opération et la tension de fonctionnement du câble chauant disponibles sont les mêmes.
Vériez le câble chauant et tous les composants pour des dommages suivant le transport. Vériez le câble chauant rigoureusement pour des dommages
à l‘enveloppe. Les câbles chauants endommagés ne peuvent pas être utilisés en raison de motifs pertinents.
Vériez le tuyau :
Vériez le tuyau pour des perles de soudure, des surfaces irrégulières ou des bords tranchants. Extrayez-les une fois que vous les trouvez. Assurez-vous que
toutes les surfaces des tuyaux sont sèches au toucher.
MISE EN
APPLICATION L‘INSTALLATION
COUVRANT ISOLEMENT
Mettez le circuit de
chauage en place. Veuillez
éviter les boucles et ne pliez
pas le circuit de chauage.
Installez le circuit de
chauage (selon l‘épaisseur
du tuyau et la puissance de
chauage requise) le long
du tuyau - en le indienne
ou multiple et xez tous les
30 cm.
Enveloppez le circuit de
chauage avec un ruban
adhésif aluminium ou du
papier aluminium an
d‘améliorer la répartition de
la chaleur.
Après l‘installation du circuit
de chauage, les tuyaux
doivent être emballés avec
du matériel d‘isolation
standard.
INSTALLATION COMME TOIT ET CHAUFFAGE GOULOTTE
SÉLECTION ET CALCUL
Il est important de tenir compte des conditions locales et du type de construction du toit par la sélection. Des constructions de toit sont généralement
classées dans les deux groupes suivants :
Toit froid : cette construction de toit est très bien isolée.
Toit chaud : cette construction de toit est très mal isolée.
Normalement, vous devez toujours calculer avec les conditions du « toit froid ».
Pour une sélection optimale du système de chauage correct, les valeurs suivantes doivent être prises en compte :
* Dimension nominale
Pour de plus grandes tailles, vous devriez augmenter la couche de bande de chauage avec le multiplicateur de conguration indiquée ci-dessous dans le
tableau.
Conguration du toit froid
Gouttière <201mm* :
Goulotte <201mm* :
Gouttière de la vallée :
Conguration du toit chaud
Gouttière <201mm* :
Goulotte <201mm* :
Gouttière de la vallée :
d
d
1
2
34
6
5
7
811
12
10
7
9
13
Dimension nominale
(mm)
200
250
280
333
400
500
Gouttière encastrée
(d)
70 mm
85 mm
120 mm
150 mm
200 mm
Multiplicateur de
conguration
1
2
2
2
3
3
Exemple : Par gouttières semi-circulaires avec des dimensions nominales de 250 à 333 mm, il est
nécessaire d‘installer deux tracés de câble chauant.
Diamètre de la goulotte
(mm)
50
60
76 et 80
87
100
120
150
Multiplicateur de
conguration
1
1
1
1
1
2
2
GOUTTIÈRES
Veuillez installer les xations de câbles à la gouttière.
La distance entre les xations de câbles doit être 0,25 m par une couche de traçage et 0,5 m par des
couches tracés multiples. Le câble chauant doit être installé sur le sol des gouttières corniches.
GOULOTTES
Qu‘une seule couche de câble chauant est requis par des goulottes avec un diamètre jusqu‘à
100 mm. Pour les tuyaux d‘un diamètre de 100 mm, la quantité de chaleur des câbles tracés doivent
être multipliées par le montant listé dans le tableau.
ATTENTION : Veuillez prendre 1 m de câble supplémentaire en compte pour la puissance et la
terminaison d‘extrémité pour des câbles chauants qui ne sont pas fabriqués en usine.
Il est recommandé que le câble chauant boucle lorsque seulement un câble chauant est utilisé et votre goulotte est placé sous-sol. Installez le câble
chauant jusqu‘à 80 cm dans le sous-sol (limite du givre) ou jusqu‘à ce que la goulotte entre avec le réseau des eaux usées. Un montant supplémentaire
de 2 m de câble chauant est requis par les tuyaux qui sont placés sous-sol. Le câble peut être installé sans corde de tension dans les goulottes moins de
10 m de longueur.
Sécurisez les brides sur le câble. Les brides doivent être xés avec une distance de 250 à 400 mm. Pour la prévention des dommages au câble chauant,
2 à 3 couches de bande en de verre tissu doivent être enroulées autour du câble sur les endroits où les colliers de câble sont sécurisés. Installez le circuit de
chauage à votre objet.
Deux couches de traçage de chauage sont requis pour les tuyaux d‘un diamètre supérieur à 100 mm. Une corde métallique avec isolation en polyéthylène
est nécessaire pour les goulottes en cuivre. Pour sécuriser le câble à la corde de tension :
Sécurisez le câble de chauage sur la corde tous les 1,5 m à l‘aide des brides.
Installez le câble chauant préparé dans la goulotte.
Protégez le câble chauant des bords tranchants.
Nous conseillons d‘utiliser un poids (max. 1 kg) à la n de la corde pour empêcher qu‘elle se torde.
VALLÉES ET LES LUCARNES
Installez les colliers à la vallée et à la tôle de la lucarne.
La distance entre les brides doit être de 0,25 m pour un traçage de chaleur d‘une couche et 0,5 m pour un traçage de chaleur à multiple couches.
SOLIN AVANT-TOIT
Les solins avant-toit sont les transitions entre les espaces du toit et les gouttières. Ils protègent ce qui est sous construction de l‘humidité. Installez les brides
à la tôle. La distance entre les brides doit être de 0,25 m pour un traçage de chaleur d‘une couche et 0,5 m pour un traçage de chaleur à multiple couches. Le
câble chauant doit être installé sur la section inférieure du solin avant-toit.
1-Goulottes
2-Lucarnes
3-Gouttière
4-Entrée de goulotte
5-Dosseret
6-Vallée
7-Dosseret
8-Râteau
9-Solin avant-toit
10-Toit plat
11/12-Espace chaué de vidange de toit
Gouttière semi-circul.
(d)
80 mm
105 mm
127 mm
153 mm
192 mm
250 mm
1
2
3
4
5
6
7
1
2
3
4
6
5
7
8
1
2
3
4
6
5
8
0,8 m
1,5 m
50mm.
60mm.
60mm.
300mm.
60mm.
14
INSTALLATIONSBEISPIELE
Montage- oder Klebeband
Anordnung des Heizkreises am Ventil
Installation von drei Schleifen
Fallrohrhalterung
Beheizter Raum
Abwassernetz
Erde ErdeErde
Gewicht
Fallrohr
Seilklemme
Heizkreis
Seil
Klemme
Installation von zwei SchleifenInstallation einer Schleife; mind. Biegeradius = 30mm
INSTALLATION EXAMPLES
Installation self-adhesive band
Installation heating circuit on valve
Installation three layers
Hanger clamp
Heated room
Sewage
Ground level Ground levelGround level
Weight
Downspout
Rope clamp
Heating section
Tension rope
Clamp
Installation two layersInstallation one layer; min. bending radius = 30mm
EXEMPLES D‘INSTALLATION
Une couche d‘installation ; rayon de courbure min. = 30mm Deux couches d‘installation
Trois couches d‘installation Bande auto-adhésive d‘installation
L‘installation de la vanne du circuit de chauage
Goulotte
Collier de suspension
Pince
Corde de tension
Section de chauage
Serre-câble
Poids
Eaux usées
Niveau du sol Niveau du sol Niveau du sol
Chambre chauée
1
2
3
4
6
5
7
9
8
1
2
3
4
6
5
7
8
1
2
3 4
6
5
7
9
8
0,5 m
1
2
3
4
6
5
7
8
0,5 m
15
Heizkabel
Seilhalterungsklemme
Heizkabelanschluss im Wellrohr
Abstandshalter
Dachrinne
Seilhalterung
Seilklemme
Seil
Fallrohr
Heizkabel
Heizkabelanschluss im Wellrohr
Abstandshalter
Halterung
Kantenschutz
Seilklemme
Seil
Fallrohr
Heating cable
Hanger clamp
Heating termination inside corrugated tube
Installation spacer
Gutter
Tension rope hanger
Rope clamp
Tension rope
Downspout
Heating cable
Heating termination inside corrugated tube
Installation spacer
Installation strip
Edge protection
Rope clamp
Tension rope
Downspout
Bande d‘installation
Câble de chauage
Goulotte
Corde de tension
Serre-câble
Protection d‘extrémité
L‘entretoise d‘installation
Chauage à l‘intérieur de la terminaison du
tube en carton ondulé
Gouttière
Câble de chauage
Goulotte
Corde de tension
Serre-câble
Cintre de corde de tension
L‘entretoise d‘installation
Chauage à l‘intérieur de la terminaison du
tube en carton ondulé
Pince de suspension
1
2
3
4
1
5
2
3
4
5
12
3
4
5
52
1
2
3
4
5
0,5m
0,25m
0,5m
0,25m
16
Stehfalz-Dacheindeckung
Wassersensor
Fallrohrhalterung
Klemme
Einlagig
Heizkabel
Heizkabelhalterung
Stehfalzhalterung
Rinnenhalterung
Fallrohr
Dichtungskleber
Dachrinne
Wellrohr
Niete
Seilklemme
Halterung
Halterung
Seil
Klemme
Dachrinne
Heizkabel
Heizkabel
Heizkabel
Zweilagig
Heizkabel
Klemme
Klemme
Klemme
Standing seam roof
Water sensor
Hanger clamp
Clamp
Single layer
Heating cable
Heating cable support
Gutter clip
Roof clip
Downspout
Glue/Sealant
Gutter
Corrugated tube
Rivet
Rope clamp
Flat bar
Flat bar
Tension rope
Clamp
Gutter
Heating cable
Heating cable
Heating cable
Double layer
Heating cable
Clamp
Clamp
Clamp
Goulotte
Pince de suspension
Pince
Corde de tension
Serre-câble
Seule couche
Pince
Gouttière
Capteur d‘eau
Rivet
Tube ondulé
Gouttière
Colle/Adhérent
Couche double
Barre plate
Câble de chauage
Pince
Barre plate
Câble de chauage
Pince
Câble de chauage
Câble de chauage
Pince
Toit à joint stationnaire
Clip de toit
Clip de gouttière
Support de câble de chauage
Câble de chauage
1
2
3
4
6
5
7
8
1
2
3
4
6
5
7
8
1
2
3
4
1
2
3
4
1
2
3
4
0,5m
0,25m
1
2
3
44
0,25m
0,10 - 0,15m
17
Traufblech
Halterung
Dachrinne
Seil
Seilhalterung
Heizkabel
Klemme
Niete
Klemme
Traufblech
Heizkabel
Klemme
Schneefangsystem
Trapezblech
Heizkabel
Fallrohr
Flashing
Bracket
Gutter
Tension rope
Tension rope hanger
Heating cable
Clamp
Rivet
Clamp
Flashing
Heating cable
Clamp
Snow retention support arm
Ribbed metal roof
Heating cable
Downspout
Pince
Gouttière
Goulotte
Câble de chauage
Toit métallique nervuré
Bras de support de conservation de la neige
Cintre de corde de tension
Corde de tension
Le support
Pince
Câble de chauage
Clignotant
Clignotant
Rivet
Pince
Câble de chauage
1
2
3
4
1
2
3
4
5
1
23
44
230 VAC, 50 Hz
15-18 W/m
10 A
+5 °C
+15 °C
+90 °C
-30 °C
30 mm
-20 °C
IP 67
12
3
45
100mm
125mm
18
Heizkabel
Spannung
Leistung
Min. notwendige Absicherung
Temperaturbereich
Heizung EIN
Heizung AUS
Max. zul. Werkstücktemperatur
Min. Betriebstemperatur
Min. Biegeradius
Min. Installationstemperatur
IP Schutzgrad
Heizkabel
Dachkehlenheizung
Fallrohr
Abstandshalter
Bitumenwellplatten bzw. Dachschindeln
Abstandshalterbefestigungsausgleich
Abstandshalterbefestigung
Abstandshalter
TECHNISCHE DATEN
Heating cable
Power supply
Linear output
Min. rated fuse size
Temperature control range
Heating ON
Heating OFF
Max. operation range
Min. operation temperature
Min. bending radius
Min. installation temperature
IP protection level
Heating cable
Valley heating
Downspout
Spacer
Bitumen well plates or roof shingles
Spacer hight dierence compensation
Spacer securing material
Spacer
TECHNICAL DATA
Câble de chauage
Tension
Sortie linéaire
Min. classe de taille de fusible
Échelle de contrôle de température
Chauage ON
Chauage OFF
Échelle de fonctionnement max.
Température de fonctionnement min.
Rayon de courbure min.
Température de l‘installation min.
Protection IP
L‘entretoise
Matériel de xation de l‘entretoise
Equilibrage du matériel de xation de l‘entretoise
Plaques à puits de bitume ou de bardeaux de toit
Câble de chauage
L‘entretoise
Goulotte
Chauage de la vallée
CARACTÉRISTIQUES TECHNIQUES
19
Alle Angaben entsprechen dem aktuellen Stand unserer Kenntnisse und sind nach bestem Wissen richtig und zuverlässig. Änderungen, Irrtümer und
Druckfehler begründen keinen Anspruch auf Schadensersatz. Für die Haung gelten ausschließlich die allgemeinen Geschäsbedingungen. Technische
Änderungen behalten wir uns ohne entsprechende Vorankündigung vor.
BEANSTANDUNGEN
Im Reklamationsfall wenden Sie sich bitte an den Verkäufer.
GARANTIE
Der Hersteller garantiert die Übereinstimmung des Heizkabels mit der Konstruktionsbeschreibung unter der Annahme der Beachtung der Montage- und
Betriebsanleitung.
Garantiezeitraum – 2 Jahre ab Kaufdatum.
Tritt innerhalb des Garantiezeitraums ein Mangel auf, des auf eine fehlerhae Herstellung zurück zu führen ist, so hat der Kunde das Recht auf
Nacherfüllung. Schäden aufgrund unsachgemäßer Handhabung, Beschädigung durch Fremdverschulden, falscher Installation (nicht der Anleitung folgend)
oder deren Folgeschäden, sind von der Garantie ausgenommen. Bitte bewahren Sie Ihren Kaufbeleg auf.
Garantieleistungen werden nur gegen Vorlage des Kaufbelegs erbracht.
All information given are believed to be reliable and correct according to the best of our knowledge. Modications, mistakes and printing errors do not
justify claims for compensation. The manufacturer‘s and supplier‘s only obligations for this product are those in the general business terms of delivery.
Specications are subject to change without prior notice.
CLAIMS
In case of a claim please contact the seller.
WARRANTY
The manufacturer guarantees the conformity of the heating cable with the design description, assuming compliance with the assembly and operating
instructions.
Warranty period – 2 years from date of purchase.
In case of a failure during guarantee period casued by a manufacturing defect, the customer has the right to supplementary performance. The warranty
does not cover any damages due to inadequate handling, damages through a third party, wrong installation (not following the manual) or its consequential
damages. Please keep your receipt.
For any warranty claims you have to show your sales receipt.
RÉCLAMATIONS
En cas de réclamation, veuillez vous adresser au vendeur.
GARANTIE
Le fabricant garantie la conformité du câble à la description du dessin, en assumant le respect des instructions de montage et de fonctionnement.
Période de garantie – 2 ans à partir de la date d‘achat.
En cas de panne lors de la période de garantie causée par à un défaut de fabrication, le client a le droit à une performance supplémentaire. La garantie ne
couvre aucun dommage dû à une manipulation inappropriée, les dommages eectués par des tiers, une mauvaise installation (non conforme au manuel)
ou ses dommages consécutifs. Veuillez conserver votre ticket.
Pour toute réclamation sous garantie, vous devrez montrer votre ticket de caisse.
Toutes les informations indiquées sont considérées comme ables et correctes au mieux de notre connaissance. Les modications, fautes et erreurs
d‘impression ne justient pas les demandes d‘indemnisation. Les seules obligations du fabricant et du fournisseur pour ce produit sont celles indiquées
dans les conditions commerciales générales de livraison. Les spécications sont sujettes à changement sans préavis.
20
GARANTIESCHEIN
Heizkreis-Typ:
Name /
Straße /
Postleitzahl, Stadt /
Land /
Tel /
Kaufdatum /
Installationsdatum /
E-Mail /
Installateuer /
Unterschri /
GUARANTEE CARD
Heating section type:
Name /
Street /
Postal Code, City /
Country /
Tel /
Purchase date /
Installation date /
e-mail /
Installer /
Signature /
CERTIFICAT DE GARANTIE
Type de section de chauage :
Nom
Rue
Code postal, ville
Pays
l
Date d‘achat
Date d‘installation
E-mail
Installateur
Signature
MI-HEAT-INST-0030-ETM-TS-HA-190918
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Mi-Heat MI-HEAT ETM, TS 15 Guide d'installation

Taper
Guide d'installation