Fantech EDP150LR Le manuel du propriétaire

Catégorie
Déshumidificateurs
Taper
Le manuel du propriétaire

Ce manuel convient également à

Read and Save These Instructions
Lisez et conservez ces instructions
Lea y guarde estas instrucciones
Industrial Dehumidifier
Déshumidificateur industriel
Deshumidificador industrial
Owner’s Manual
OPERATION AND MAINTENANCE MANUAL
Industrial Dehumidifier
Déshumidificateur industriel
Deshumidificador industrial
Operating Instructions
Guide d'utilisation
Instrucciones de uso
Read and Save
These
Instructions
Lisez et
conservez ces
instructions
Lea y guarde
estas
instrucciones
1
3
5
405037
Fantech Ltd. 1-800-565-3548
Models / Modèles / Modelos
EDP150LR
EDP180CR
EDP190LR
EDP250CR
2
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
WARNING
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15
amp circuit is required. If used in a wet area, a ground fault
interrupter (GFI) is required.
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord
must be plugged into a properly grounded receptacle. If a
grounded receptacle does not exist, have one installed by a
certified electrician. Do not cut or remove the grounding
prong on the power cord plug if equipped. We recommend
that this electrical circuit/receptacle operate under a
separate breaker or fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Limitations of Use
Temperature: 4°C to 35°C (40°F to 95°F)
Relative Humidity: 20 to 80%
Water Removal
The dehumidifier is equipped with an internal condensate
pump to remove the water that is collected from the air. This
allows the water to be pumped 20 feet with the attached
hose. If the water needs to be pumped more than 20 feet
above the unit, a second pump must be added to relay the
water. The condensate pump automatically purges for 20
seconds every four minutes.
OPERATION
Place dehumidifier inside area to be dried. Make sure all
windows and doors are closed to the outside and seal off the
wet area from any unaffected areas. Route condensate hose
into a drain, or a very large container. Press the On/Off
button (Fig. 1) to activate the dehumidifier.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter
will display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will
automatically empty the reservoir.
Pressing this button allows manual
emptying of the reservoir. Press once,
and the pump will operate for 20
seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water res-
ervoir before transport or storage.
Turn off the power and allow the plugged in dehumidifier to
rest 5 minutes before the final purge.
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running
hours of the unit in 1/10 of an hour.
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
Fig. 3
Hour Button (Fig. 4)
Press the HOURS button when the
dehumidifier cannot be plugged in and
the hour meter needs to be read. The
digital hour meter will display the last
saved cumulative time for ten seconds.
Battery Replacement
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
WARNING
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
Electrical Shock Hazard
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death, fire, or
electrical shock.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is
necessary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the
electronic control and defrost light. The compressor is turned
off by the thermistor temperature measurement. The blower will
continue to run, causing air to flow through the evaporator coil
and melt the ice. When the ice is melted, the thermistor will end
the defrost cycle and the compressor will
be started.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate
the dehumidifier is in defrost cycle. During
this period, the compressor is not running.
Fig. 1
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
Fig. 2
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
Fig. 4
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
Fig. 5
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
Industrial Dehumidifier
3
Industrial Dehumidifier
Venting / Ducting (Fig. 6)
Twin rear outlets can accom-
modate two individual 5” ducts
or one 10” lay flat duct to be
attached. This allows for warm
dry air to be directed into dif-
ferent areas.
MAINTENANCE
Air Filter (Fig. 7)
The air filter should be checked regularly. Operating the
dehumidifier with a clogged filter will reduce efficiency. To
access the filter, slide the filter frame up until it clears the
dehumidifier cabinet. Reverse procedure to re-install the fil-
ter into the dehumidifier.
MAINTENANCE
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
WARNING
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
Electrical Shock Hazard
Disconnect power supply before cleaning.
Failure to follow these instructions can result in death, fire, or
electrical shock.
External Cleaning
Use a non-flammable mild, non-abrasive soap and clean
water solution to clean the dehumidifier. Wipe dry.
Internal Cleaning
Disconnect dehumidifier from power supply.
Light cleaning: Remove the air filter and spray evaporator coil
with water. Remove the two upper screws from the fronthood.
Heavy cleaning: Remove two upper screws from front hood.
Open hood. Spray water at coils. Close hood and replace
screws. (Fig. 8)
Fig. 8
Maintenance
Air Filter (Fig. 7)
The air filter should be checked regularly. Operating the dehu-
midifier with a clogged filter will reduce efficiency. The filter can be
vacuum cleaned to remove dust. To access the filter media, slide
the filter frame up until it clears the dehumidifier cabinet. Remove
the filter media from behind the frame and vacuum. Reverse pro-
cedure to re-install the filter and frame into the dehumidifier.
Storage
Freezing temperatures and biological growth must be considered
before storing the dehumidifier. The dehumidifier should be
flushed with a biofungicide before storing. When storing the unit,
ensure that water has been removed from the reservoir and
hose. This will prevent damage caused by freezing temperatures
and to prevent biological growth. Use the pump purge button to
remove water and biofungicide chemicals from the dehumidifier.
Stacking (Fig.9)
The dehumidifiers can be stacked on top of each other. The
wheels from the upper unit must be resting in the cradle of
the lower unit. DO NOT STACK MORE THAN TWO HIGH.
External Cleaning
Use a non-flammable mild, non-abrasive soap and clean
water solution to clean the dehumidifier. Wipe dry.
Internal Cleaning
Disconnect dehumidifier from power supply.
Light cleaning: Remove the air filter and spray evaporator
coil with water.Remove the two upper screws from the front
hood.
Heavy cleaning: Remove two upper screws from front hood.
Open hood. Spray water at coils. Close hood and replace
screws. (Fig. 8)
Fig. 7
Fig. 8
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before cleaning.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Venting / Ducting (Fig. 6)
Twin rear outlets can accommo-
date two individual 5” ducts or one
10” lay flat duct to be attached.
This allows for warm dry air to be
directed into different areas.
Fig. 6
Cleaning
Fig. 9
Service
A qualified refrigeration technician must service all refriger-
ant leaks.
WARNING: The dehumidifier uses a high pressure refrigerant
system and high voltage circuitry which could present a health
hazard resulting in death, serious bodily injury, and/or property
damage. Only qualified service people should service this unit.
CAUTION: Do not operate unit without the front hood secured in
place.
The serial data plate is located on the underside of the dehumid-
ifier. For service information contact 1-800-565-3548.
(2)
Storage
Freezing temperatures and biological growth must be consid-
ered before storing the dehumidifier. The dehumidifier should
be flushed with a biofungicide before storing. When storing
the unit, ensure that water has been removed from the res-
ervoir and hose. This will prevent damage caused by freezing
temperatures and to prevent biological growth. Use the
pump purge button to remove water and biofungicide chemi-
cals from the dehumidifier.
Stacking (Fig. 9)
The dehumidifiers can be stacked on top of each other. The
wheels from the upper unit must be resting in the cradle of
the lower unit. DO NOT STACK MORE THAN TWO HIGH.
Fig. 9
Service
A qualified refrigeration technician must service all refriger-
ant leaks.
WARNING: The dehumidifier uses a high pressure refrigerant
system and high voltage circuitry which could present a
health hazard resulting in death, serious bodily injury, and/or
property damage. Only qualified service people should service
this unit.
CAUTION: Do not operate unit without the front hood secured
in place.
The serial data plate is located on the underside of the dehu-
midifier. For service information contact 1-800-565-3548.
Maintenance
Air Filter (Fig. 7)
The air filter should be checked regularly. Operating the dehu-
midifier with a clogged filter will reduce efficiency. The filter can be
vacuum cleaned to remove dust. To access the filter media, slide
the filter frame up until it clears the dehumidifier cabinet. Remove
the filter media from behind the frame and vacuum. Reverse pro-
cedure to re-install the filter and frame into the dehumidifier.
Storage
Freezing temperatures and biological growth must be considered
before storing the dehumidifier. The dehumidifier should be
flushed with a biofungicide before storing. When storing the unit,
ensure that water has been removed from the reservoir and
hose. This will prevent damage caused by freezing temperatures
and to prevent biological growth. Use the pump purge button to
remove water and biofungicide chemicals from the dehumidifier.
Stacking (Fig.9)
The dehumidifiers can be stacked on top of each other. The
wheels from the upper unit must be resting in the cradle of
the lower unit. DO NOT STACK MORE THAN TWO HIGH.
External Cleaning
Use a non-flammable mild, non-abrasive soap and clean
water solution to clean the dehumidifier. Wipe dry.
Internal Cleaning
Disconnect dehumidifier from power supply.
Light cleaning: Remove the air filter and spray evaporator
coil with water.Remove the two upper screws from the front
hood.
Heavy cleaning: Remove two upper screws from front hood.
Open hood. Spray water at coils. Close hood and replace
screws. (Fig. 8)
Fig. 7
Fig. 8
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before cleaning.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Venting / Ducting (Fig. 6)
Twin rear outlets can accommo-
date two individual 5” ducts or one
10” lay flat duct to be attached.
This allows for warm dry air to be
directed into different areas.
Fig. 6
Cleaning
Fig. 9
Service
A qualified refrigeration technician must service all refriger-
ant leaks.
WARNING: The dehumidifier uses a high pressure refrigerant
system and high voltage circuitry which could present a health
hazard resulting in death, serious bodily injury, and/or property
damage. Only qualified service people should service this unit.
CAUTION: Do not operate unit without the front hood secured in
place.
The serial data plate is located on the underside of the dehumid-
ifier. For service information contact 1-800-565-3548.
(2)
Fig. 6
Fig. 7
4
TROUBLESHOOTING
The Unit is NOT working:
• Why do you believe the dehumidifier is not working?
• Is the power ON?
• Has the breaker tripped? – Reset breaker
If in a wet area, is the unit plugged into a GFI protected cir-
cuit? – Excessive moisture will trip GFI. Remove from area.
• Is the unit being run off a generator? - Check output does
not fluctuate as the unit will not operate at low voltage.
• If using an extension cord - Is the cord of the correct
gauge for the distance run? (14 AWG up to 25and 12
AWG over 25’). Note: Verify voltage while unit is starting.
Start up will cause the highest current draw and largest
voltage drop. Even if plugged directly to outlet there can
be a significant voltage drop. Never assume the voltage is
ok without verifying.
• Is the unit draining? – Check the condensate receptacle.
If full, the float is up and the unit will not operate – drain
receptacle.
• Overpressure switch tripped. Check for fan failure or high
ambient temperature. Display panel indicates defrost.
The unit continually ices up: Note that some ice buildup on the
evaporator coils is normal but airflow should not be blocked.
• Is the fan working? – Fan not working, check run capacitor
and fan unit.
• Is warm air blowing out the front of the unit? - No warm
air, temperature may be too low. Raise temperature with
supplementary source.
• Is the air filter clean and airflow unobstructed? Clean
filter. Unit should have a minimum of 10” clearance all
around it.
• Dirty evaporator coils? – Clean coils.
• Defrost thermostat loose or not working? Secure or
replace.
• Defrost timer set incorrectly or defective? Reset or
replace.
• Temperature in the operating space is too low? - Raise
temperature with supplementary source.
Unit moves some water but not as much as expected:
Air temperature and Relative Humidity have dropped - Check
levels with calibrated humidity meter and/or thermostat.
• Unit is in defrost cycle – Unit will start after cycle.
• Air filter dirty or airflow obstructed - Unit should have a
minimum of 10” clearance all around it. Clean air filter and
ensure adequate airflow/space around unit.
• Evaporator coils dirty – Clean coils.
• Restrictive or kinked exhaust ducting (if used) Straighten
out ducting.
• Defrost timer set incorrectly for conditions – Reset timer.
• Defrost thermostat defective - Replace
• Refrigerant charge is low – Have unit checked by qualified
technician
• Defective compressor Replace compressor by qualified
technician as it requires recycling of refrigerant.
Unit runs continuously for days:
• Unit is working removing water - High Relative Humidity
in space.
• Humidity or water is getting into the space – Find source
and stop it.
• Unit is undersized for space Use larger unit or mul-
tiple units.
• Poor air movement in space Use air movers to
increase movement.
Unit runs but does not pump water:
• Drain hose kinked or blocked Straighten or unblock hose.
• Pump float stuck closed – Reset or replace.
• Pump not working Check electrical operation with out-
side supply.
• Hose disconnected internally – Reconnect hose.
• Compressor capacitor bad – Check capacitor.
Fan runs but Compressor does not:
• Condensate pump not working – Check pump and float.
• Bad connection in pump circuit – Check connections.
• Bad compressor capacitor – Check capacitor.
• Defective control board – Replace.
• Defective compressor Replace compressor by quali-
fied technician.
• Defective time delay or Thermistor Check and/or replace.
• Defective pressure switch – Check and replace.
Fan does not run. Compressor runs briefly but cycles on/off:
• Defective fan capacitor – Check capacitor.
• Loose connection in fan circuit – Check connections.
• Fan obstructed and not turning – Remove obstruction.
• Defective fan – Replace fan.
• Defective control board – Replace control board.
5
WIRING DIAGRAMS
EPD150LR, EPD180CR
EPD190LR, EPD250CR
6
WARRANTY - ONE YEAR
This product is warranted against defects in material and workmanship
for a period of one year from the date of purchase by the original pur-
chaser. During this period, all parts and labor will be provided at no
cost. Consumable parts (ie: light bulbs and filters) are not warranted
or guaranteed for any length of time. This warranty is non transferable.
ADDITIONAL SIX YEAR WARRANTY
For a period of six years following the ONE YEAR WARRANTY compo-
nents of the sealed system are warranted against defects in material.
Parts will be supplied (freight prepaid) free of charge. Installation labor
is not covered. This warranty is non transferable.
LIFETIME WARRANTY ON ROTOMOLDED HOUSING
The Rotomolded housing of this product carries a lifetime warranty.
This warranty is non transferable.
NOTICE
1. This warranty applies only to the original purchaser and applies
only within the boundaries of CANADA and CONTINENTAL USA.
2. This is the only warranty of the dealer and Fantech Limited. for
the above mentioned product and no other warranty or condition,
expressed or implied shall apply, except where specifically
excluded by law.
3. The original purchaser should complete this warranty form and
retain it in the event warranty service is required.
4. Proof of purchase date will be required for warranty claims.
Please retain bills of sale for proof.
5. Some states do not allow the exclusion or limitation of incidental
or consequential damages, so the above limitation or exclusion
may not apply to you. This warranty gives specific legal rights, and
the purchaser may have other rights which vary from state to
state. For more information regarding legal rights the purchaser
may contact the local or state consumer affairs office or the
appropriate state Attorney General.
LIMITED PRODUCT WARRANTY
GENERAL PROVISIONS
No warranty or insurance herein contained or set out shall apply when
damage or repair is caused by any of the following:
1. Power failure.
2. Damage in transit or when moving the appliance.
3. Improper power supply such as low voltage, defective house wir-
ing or inadequate fuses.
4. Accident, alteration, abuse or misuse of the appliance such as
inadequate air circulation in the room or abnormal operating
conditions, (extremely high or low room temperatures).
5. Fire, water, damage, theft, war, riot, hostility, acts of God such as
hurricanes, floods, etc.
For information concerning your warranty, contact:
In Canada
Fantech
50 Kanalflakt Way,
Bouctouche, NB E4S 3M5
Phone: 800.565.3548; 506.743.9500
Fax: 877.747.8116; 506.743.9600
In Continental USA
Fantech
10048 Industrial Blvd.
Lenexa, KS 66215
Phone: 800.747.1762; 913.752.6000
Fax: 800.487.9915; 913.752.6466
Industrial Dehumidifier
Model Number Serial Number
Date of Purchase Customer Name
Address City
Purchased from
7
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
AVERTISSEMENT
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
Risque de choc électrique
Brancher sur une prise à 3 alvéoles reliée à la terre.
Ne pas enlever la broche de liaison à la terre.
Ne pas utiliser un adaptateur.
Ne pas utiliser un câble de rallonge.
Le non-respect de ces instructions peut causer un décès, un
incendie ou un choc électrique.
Alimentation
Pour le fonctionnement sous une tension de 115 V, une prise
mise à la terre ordinaire d’un circuit de 15 ampères est
nécessaire. S’il est utilisé dans une aire humide, l’usage d’un
disjoncteur de fuite de terre (DFT) est nécessaire.
Dispositif de sécurité électrique intégré
Dans le but d'assurer votre sécurité et votre protection, cet
appareil est muni d’un cordon d’alimentation avec fiche mise
à la terre. Le cordon d’alimentation doit être branché dans
une prise convenablement mise à la terre. S’il n’y a pas de
prise mise à la terre, faites-en installer une par un électricien
agréé. Ne coupez pas et n’enlevez pas la broche de mise à
la terre de la fiche du cordon d'alimentation s'il y en a une.
Nous recommandons d’utiliser ce circuit électrique ou cette
prise avec un disjoncteur ou un fusible distinct.
Si une rallonge électrique doit être utilisée, elle doit
comporter des conducteurs d’un calibre minimum de 14 si
elle fait 25 pieds de long ou moins et des conducteurs de
calibre 12 si elle fait plus de 25 pieds.
Limitations d'usage
Limitations d'usage
Température: 4ºC à 35'C (40ºF à 95ºF)
Humidité relative: 20 à 80%
Enlèvement de l'eau
Le déshumidificateur est équipé d’une pompe à condensats
interne servant à enlever l’eau retirée de l’air. Elle permet de
pomper l’eau à vingt pieds avec le tuyau fixé à l’appareil. Si
l’eau doit être pompée à plus de vingt pieds au-dessus de
l’unité, il faut ajouter une seconde pompe à laquelle l’eau est
envoyée. La pompe à condensats se purge automatiquement
pendant vingt secondes toutes les quatre minutes.
FONCTIONNEMENT
Placez leshumidificateur à l’intérieur de l’aire àcher.
Assurezvous que toutes les fenêtres et les portes sont feres
et isolez l’aire humide des ires non touces. Faites aboutir le
tuyau à condensats à un drain ou à un très gros contenant.
Appuyez sur le bouton On/Off (Fig. 1)
pour activer le déshumidificateur.
Bouton de mise en marche (Fig. 1)
On allume ou éteint le shumidificateur
en appuyant sur le bouton de mise en
marche. Lorsque le déshumidificateur se
met en marche, le compteur d’heures
affiche le total cumu des heures.
Bouton de purge de la pompe (Fig. 2)
En fonctionnement normal, la pompe
videra automatiquement le servoir. En
appuyant sur ce bouton, on peut vider
manuellement le réservoir. Si vous
appuyez une fois, la pompe fonctionnera
pendant vingt secondes. Si vous appuyez
sur le bouton et le maintenez enfoncé, la pompe sera activée
pendant trente secondes.
Purgez toujours manuellement le
réservoir d’eau avant de transporter ou d’entreposer la
pompe. Coupez l’alimentation et laissez le déshumidificateur
branché reposer pendant cinq minutes avant la purge finale.
Compteur d’heures numérique (Fig. 3)
Le compteur comptabilise et affiche le total des heures de
fonctionnement de l’unité en dixièmes d’heure.
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
Fig. 3
Bouton des heures (Fig. 4)
Appuyez sur le bouton HEURES lorsque
le shumidificateur ne peut être
branché et qu’il faut lire l’affichage du
compteur d’heures. Le compteur
d’heures numérique affichera le dernier
total cumulé des heures sauvegardé
pendant dix secondes.
Remplacement de la pile
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
AVERTISSEMENT
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
Risque de choc électrique
Débranchez l'alimentation avant de remplacer la pile.
Le fait de ne pas suivre ces instructions peut entraîner la mort,
un incendie ou un choc électrique.
Débranchez le déshumidificateur de son alimentation électrique.
Le compteur d’heures utilise une pile de secours pour l’affichage
lorsque le déshumidificateur est débranché et que le bouton des
heures est enfoncé. Pour changer la pile, il est nécessaire
d’enlever les quatre (4) vis du panneau de contrôle. Débranchez
l’ancienne pile et remplacez-la par une nouvelle. Remettez en place
le panneau de contrôle et les vis. Ne serrez pas trop les vis.
Cycle de dégivrage
Lorsque de la glace s’accumule sur les serpentins, une thermistance
active le contle électronique et la lumre de givrage. Le
compresseur est éteint par la mesure de la température par la
thermistance. Le ventilateur continue de fonctionner, ce qui fait
circuler à travers le serpentin de lévaporateur l’air qui fait fondre
la glace. Lorsque la glace est fondue, la thermistance met fin au
cycle de dégivrage et le compresseur est mis en marche.
Indicateur de dégivrage (Fig. 5)
L’indicateur de dégivrage s’allume pour
indiquer que le déshumidificateur est en
cours de cycle de dégivrage. Au cours
de cette période, le compresseur ne
fonctionne pas.
Fig. 1
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
Fig. 2
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
Fig. 4
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
Fig. 5
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
Déshumidificateur industriel
8
Déshumidificateur industriel
Ventilation/Canalisation (Fig. 6)
Deux évents arrières peuvent
recevoir deux canalisations dis-
tinctes de cinq pouces ou une
unique canalisation plate de dix
pouces à fixer. Ceci permet de
diriger l’air chaud et sec vers
différentes aires.
ENTRETIEN
Filtre à air (Fig. 7)
Le filtre à air doit être inspecté régulièrement. Si le
déshumidificateur est utilisé avec un filtre colmaté, l’efficacité
sera réduite. Pour accéder au matériau filtrant, faites
glisser le châssis du filtre vers le haut jusqu'à ce qu'il soit
sorti de la carrosserie du déshumidificateur. Inversez la
procédure pour réinstaller le filtre dans le déshumidificateur.
NETTOYAGE
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
AVERTISSEMENT
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
Risque de choc électrique
Débranchez l’alimentation avant le nettoyage.
Le fait de ne pas suivre ces instructions peut entraîner la mort,
un incendie ou un choc électrique.
Nettoyage externe
Utilisez une solution de détergent doux, non inflammable et
non abrasif et d’eau propre pour nettoyer le déshumidifica-
teur. Essuyez-le bien.
Nettoyage interne
Débranchez le déshumidificateur de son alimentation électrique.
Nettoyage léger:
Enlevez le filtre à air et vaporisez de l’eau sur
le serpentin de l'évaporateur. Enlevez les deux vis surieures
sur le capot avant.
Nettoyage en profondeur: Enlevez les deux vis surieures sur le
capot avant. Ouvrez le capot. Vaporisez de l’eau sur les serpen-
tins. Fermez le capot et remettez les vis en place. (Fig. 8)
Fig. 8
Maintenance
Air Filter (Fig. 7)
The air filter should be checked regularly. Operating the dehu-
midifier with a clogged filter will reduce efficiency. The filter can be
vacuum cleaned to remove dust. To access the filter media, slide
the filter frame up until it clears the dehumidifier cabinet. Remove
the filter media from behind the frame and vacuum. Reverse pro-
cedure to re-install the filter and frame into the dehumidifier.
Storage
Freezing temperatures and biological growth must be considered
before storing the dehumidifier. The dehumidifier should be
flushed with a biofungicide before storing. When storing the unit,
ensure that water has been removed from the reservoir and
hose. This will prevent damage caused by freezing temperatures
and to prevent biological growth. Use the pump purge button to
remove water and biofungicide chemicals from the dehumidifier.
Stacking (Fig.9)
The dehumidifiers can be stacked on top of each other. The
wheels from the upper unit must be resting in the cradle of
the lower unit. DO NOT STACK MORE THAN TWO HIGH.
External Cleaning
Use a non-flammable mild, non-abrasive soap and clean
water solution to clean the dehumidifier. Wipe dry.
Internal Cleaning
Disconnect dehumidifier from power supply.
Light cleaning: Remove the air filter and spray evaporator
coil with water.Remove the two upper screws from the front
hood.
Heavy cleaning: Remove two upper screws from front hood.
Open hood. Spray water at coils. Close hood and replace
screws. (Fig. 8)
Fig. 7
Fig. 8
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before cleaning.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Venting / Ducting (Fig. 6)
Twin rear outlets can accommo-
date two individual 5” ducts or one
10” lay flat duct to be attached.
This allows for warm dry air to be
directed into different areas.
Fig. 6
Cleaning
Fig. 9
Service
A qualified refrigeration technician must service all refriger-
ant leaks.
WARNING: The dehumidifier uses a high pressure refrigerant
system and high voltage circuitry which could present a health
hazard resulting in death, serious bodily injury, and/or property
damage. Only qualified service people should service this unit.
CAUTION: Do not operate unit without the front hood secured in
place.
The serial data plate is located on the underside of the dehumid-
ifier. For service information contact 1-800-565-3548.
(2)
Entreposage
Il faut tenir compte des risques de gel et de croissance biologique
avant d’entreposer le shumidificateur. Le shumidificateur
devrait être pur avec un biofongicide avant l’entreposage.
Avant d’entreposer l’unité, assurez-vous que l’eau a é enlee
du réservoir et du tuyau. Ceci permettra d’éviter les dommages
caus par le gel ainsi que la croissance biologique. Utilisez le
bouton de purge de la pompe pour enlever l’eau et les produits
chimiques biofongicides du déshumidificateur.
Empilage (Fig. 9)
Les déshumidificateurs peuvent être empilés. Les roulettes
de l’unité supérieure doivent être posées dans le berceau de
l’unité inférieure. NE PAS EN EMPILER PLUS DE DEUX.
Maintenance
Air Filter (Fig. 7)
The air filter should be checked regularly. Operating the dehu-
midifier with a clogged filter will reduce efficiency. The filter can be
vacuum cleaned to remove dust. To access the filter media, slide
the filter frame up until it clears the dehumidifier cabinet. Remove
the filter media from behind the frame and vacuum. Reverse pro-
cedure to re-install the filter and frame into the dehumidifier.
Storage
Freezing temperatures and biological growth must be considered
before storing the dehumidifier. The dehumidifier should be
flushed with a biofungicide before storing. When storing the unit,
ensure that water has been removed from the reservoir and
hose. This will prevent damage caused by freezing temperatures
and to prevent biological growth. Use the pump purge button to
remove water and biofungicide chemicals from the dehumidifier.
Stacking (Fig.9)
The dehumidifiers can be stacked on top of each other. The
wheels from the upper unit must be resting in the cradle of
the lower unit. DO NOT STACK MORE THAN TWO HIGH.
External Cleaning
Use a non-flammable mild, non-abrasive soap and clean
water solution to clean the dehumidifier. Wipe dry.
Internal Cleaning
Disconnect dehumidifier from power supply.
Light cleaning: Remove the air filter and spray evaporator
coil with water.Remove the two upper screws from the front
hood.
Heavy cleaning: Remove two upper screws from front hood.
Open hood. Spray water at coils. Close hood and replace
screws. (Fig. 8)
Fig. 7
Fig. 8
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before cleaning.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Venting / Ducting (Fig. 6)
Twin rear outlets can accommo-
date two individual 5” ducts or one
10” lay flat duct to be attached.
This allows for warm dry air to be
directed into different areas.
Fig. 6
Cleaning
Fig. 9
Service
A qualified refrigeration technician must service all refriger-
ant leaks.
WARNING: The dehumidifier uses a high pressure refrigerant
system and high voltage circuitry which could present a health
hazard resulting in death, serious bodily injury, and/or property
damage. Only qualified service people should service this unit.
CAUTION: Do not operate unit without the front hood secured in
place.
The serial data plate is located on the underside of the dehumid-
ifier. For service information contact 1-800-565-3548.
(2)
Fig. 9
Réparations
Toutes les fuites de fluide frigorigène doivent être réparées
par un technicien en réfrigération qualifié.
AVERTISSEMENT: Le déshumidificateur contient un sysme de
fluide frigorigène à haute pression et des circuits à haute tension
qui pourraient psenter un danger pour la santé et entraîner la
mort, des blessures graves et/ou des dommages mariels.
Seuls des réparateurs qualifs devraient réparer cette uni.
ATTENTION: Ne pas faire fonctionner l’unité si le capot avant
n’est pas bien en place.
Le numéro de sériie est situé sur le dessous du déshumidifi-
cateur. Pour obtenir des informations sur l’entretien, appelez
le 1- 800-565-3548.
Maintenance
Air Filter (Fig. 7)
The air filter should be checked regularly. Operating the dehu-
midifier with a clogged filter will reduce efficiency. The filter can be
vacuum cleaned to remove dust. To access the filter media, slide
the filter frame up until it clears the dehumidifier cabinet. Remove
the filter media from behind the frame and vacuum. Reverse pro-
cedure to re-install the filter and frame into the dehumidifier.
Storage
Freezing temperatures and biological growth must be considered
before storing the dehumidifier. The dehumidifier should be
flushed with a biofungicide before storing. When storing the unit,
ensure that water has been removed from the reservoir and
hose. This will prevent damage caused by freezing temperatures
and to prevent biological growth. Use the pump purge button to
remove water and biofungicide chemicals from the dehumidifier.
Stacking (Fig.9)
The dehumidifiers can be stacked on top of each other. The
wheels from the upper unit must be resting in the cradle of
the lower unit. DO NOT STACK MORE THAN TWO HIGH.
External Cleaning
Use a non-flammable mild, non-abrasive soap and clean
water solution to clean the dehumidifier. Wipe dry.
Internal Cleaning
Disconnect dehumidifier from power supply.
Light cleaning: Remove the air filter and spray evaporator
coil with water.Remove the two upper screws from the front
hood.
Heavy cleaning: Remove two upper screws from front hood.
Open hood. Spray water at coils. Close hood and replace
screws. (Fig. 8)
Fig. 7
Fig. 8
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before cleaning.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Venting / Ducting (Fig. 6)
Twin rear outlets can accommo-
date two individual 5” ducts or one
10” lay flat duct to be attached.
This allows for warm dry air to be
directed into different areas.
Fig. 6
Cleaning
Fig. 9
Service
A qualified refrigeration technician must service all refriger-
ant leaks.
WARNING: The dehumidifier uses a high pressure refrigerant
system and high voltage circuitry which could present a health
hazard resulting in death, serious bodily injury, and/or property
damage. Only qualified service people should service this unit.
CAUTION: Do not operate unit without the front hood secured in
place.
The serial data plate is located on the underside of the dehumid-
ifier. For service information contact 1-800-565-3548.
(2)
Fig. 6
Fig. 7
9
DÉPANNAGE
Lunité ne fonctionne pas:
Pourquoi pensez-vous que le déshumidificateur ne fonctionne pas?
Est-ce que l’appareil est sous tension?
• Est-ce que le disjoncteur s’est déclenché? Réinitialiser
le disjoncteur.
Si l’appareil est dans un endroit humide, est-ce qu’il est
branc dans un disjoncteur de fuite de terre (DFT)?–
Lhumidi excessive peut clencher le DFT. Enlever l’appareil
de cet endroit.
Est-ce que l’appareil est branché à uneratrice? –
Vérifiez que la sortie ne varie pas, car l’appareil ne peut pas
orer à basse tension.
Si vous utilisez une rallonge Est-ce que la rallonge est du bon
calibre pour la distance nécessaire? (14 AWG jusquà 25pi et
12 AWG au-de de 25pi). Note: Vérifiez la tension pendant le
démarrage de lappareil. Le marrage nécessitera un plus
grand courant et donc la plus grande baisse de tension. Même
si lappareil est branc directement à une prise de courant, il
peut y avoir une baisse de tension significative. Ne jamais
assumer que la tension est correcte sans vérifier.
Est-ce que le drainage se produit? Vérifiez le ceptacle de
condensat. S’il est plein, le flotteur est en haut et l’appareil
ne fonctionnera pas – videz le réceptacle.
Linterrupteur de surpression sest déclenché. Vérifiez si le ven-
tilateur a cessé de fonctionner ou que la température ambiante
est trop élevée. Le panneau daffichage indique le dégivrage.
Lappareil devient glacée constamment: Notez quun peu de glace sur
lévaporateur est normal, mais le passage dair ne devrait jamais être bloqué.
Est-ce que le ventilateur fonctionne? Si le ventilateur ne
fonctionne pas, vérifiez le condensateur du moteur ainsi que
l’appareil du ventilateur.
Est-ce que l’air chaud sort du devant de l’appareil? - S’il n’y a
pas d’air chaud, la temrature ambiante est peut-être trop
basse. Augmentez la température ambiante avec une source
externe suppmentaire.
Est-ce que le filtre à air est propre et le passage d’air
dégagé?Nettoyez le filtre. L’appareil devrait avoir un espace
minimum vide de 10po tout autour.
Est-ce que l’évaporateur est sale? – Nettoyez l’évaporateur.
Est-ce que le thermostat de dégivrage estche ou ne fonc-
tionne pas? – Fixez le thermostat ou remplacez-le.
Est-ce que le thermostat de dégivrage est réglé incorrectement
ou défectueuse? Réinitialisez le thermostat ou remplacez-le.
Est-ce que la temrature ambiante est trop basse?
Augmentez la température avec une source suppmentaire.
Lappareil accumule de l’eau, mais moins que pvu:
La température de l’air et l’humidité relative ont baissés
Vérifiez la temrature et l’humidi relative avec un
hygrotre calib et/ou un thermostat.
L’appareil est en cycle de givrage L’appareil recom-
mencera aps le cycle.
Filtre à air est sale ou le passage dair est obstrué
Lappareil devrait avoir un espace minimum vide de 10po tout
autour. Nettoyez le filtre à air et assurez un passage d’air
aquat/espace vide autour de l’appareil.
Est-ce que l’évaporateur est sale? – Nettoyez l’évaporateur.
Conduits d’échappement restrictives ou formés (si utili-
sés) – Redressez les conduits.
Minuterie de dégivrage est glée incorrectement
Réinitialisez la minuterie.
Minuterie de dégivrage est défectueuse Remplacez la minuterie.
La charge defrigérant est faible – Faitesrifiez l’appareil
par un technicien qualif.
Compresseur est fectueux Faites remplacer le compres-
seur par un technicien qualifié car cela nécessite le recyclage
des réfrigérants.
Lappareil est en marche continuellement pendant plusieurs jours:
L’appareil accumule beaucoup d’eau – L’humidité relative
dans l’espace est élevée.
• L’humidité ou l’eau entre dans l’espace – Trouvez la
source et arrêtez-la.
L’appareil est trop petite pour l’espace Utilisez un plus
grand appareil ou plusieurs appareils.
Mauvaise circulation d’air dans l’espace Utilisez un appareil
pour augmenter la circulation de l’air.
L’appareil fonctionne mais ne pompe pas d’eau:
• Tuyau de vidange plié ou bloqué Redressez ou blo-
quez le tuyau.
• Flotteur bloqué en position fermée Réinitialisez ou
remplacez le flotteur.
• Pompe ne fonctionne pas Vérifiez le fonctionnement
électrique de la source externe.
• Tuyau débrancà l’interne Rebranchez le tuyau.
• Condensateur du compresseur défectueux Vérifiez le
condensateur.
Le ventilateur fonctionne, mais non le compresseur:
Pompe de condensats ne fonctionne pas – Vérifiez la pompe
et le flotteur.
Mauvaise connexion dans le circuit électrique de la pompe
Vérifiez les connexions.
• Condensateur du compresseur défectueux Vérifiez le
condensateur.
• Circuit électrique défectueux Remplacez le circuit.
Compresseur fectueux Faites remplacer le compresseur
par un technicien qualif.
Minuterie de délai ou thermistance défectueuse Vérifiez et/
ou remplacez.
Pressostat défectueux – Vérifiez et/ou remplacez.
Le ventilateur ne fonctionne pas. Compresseur fonctionne brve-
ment mais en cycles (marche/arrêt):
• Condensateur du ventilateur est défectueux Vérifiez le
condensateur.
Mauvaise connexion dans le circuit du ventilateur Vérifiez
les connexions.
Ventilateur est obstrué et ne tourne pas Enlevez lobstruction.
Ventilateur est défectueux – Remplacez le ventilateur.
Circuit électrique défectueux – Remplacez le circuit.
10
SCHÉMAS ÉLECTRIQUES
EPD150LR, EPD180CR
EPD190LR, EPD250CR
11
GARANTIE – UN AN
Ce produit est garanti contre tous les défauts de pièces et de main-
d'oeuvre pour une période d'un an à compter de la date d’achat par
l’acheteur initial. Au cours de cette période, toutes les pièces et la
main-d'oeuvre seront fournies sans frais. Les pièces consommables
(par exemple, les ampoules électriques et les filtres) ne font l’objet
d’aucune garantie. Cette garantie n’est pas transférable.
GARANTIE SUPPLÉMENTAIRE DE SIX ANS
Les composantes du système scellé sont garanties contre les défauts
de matériaux pour la période de six ans qui suit l’expiration de la
GARANTIE D'UN AN. Les pièces seront fournies (frais de port payés
d’avance) sans frais. Les frais de main-d'oeuvre pour l’installation ne
sont pas couverts. Cette garantie n’est pas transférable.
GARANTIE À VIE SUR BOÎTIER ROTOMOULÉ
Le boîtier rotomoulé de ce produit est garanti à vie. Cette garantie
n'est pas transférable.
AVIS
1. Cette garantie ne s’applique qu’à l’acheteur initial et seulement
dans les limites des frontières du CANADA et des ÉTATS-UNIS
CONTINENTAUX.
2. La présente constitue la seule garantie offerte par le détaillant et
Fantech Limited pour le produit susmentionné et aucune autre
garantie ou condition, explicite ou implicite, ne s’appliquera, à
moins d’exclusion contraire expressément imposée par la loi.
3. L’acheteur initial devrait remplir le présent formulaire de garantie
et le conserver pour le cas des réparations couvertes par la
garantie seraient nécessaires
4. La date de la preuve d’achat sera exigée pour les réclamations au
titre de la garantie. Veuillez conserver les actes de vente à titre
de preuve.
5. Certains États ne permettent pas l’exclusion ou la limitation des
dommages consécutifs ou indirects, de sorte que la limitation ou
l’exclusion ci-dessus pourrait ne pas s’appliquer à vous. Cette
garantie donne des droits légaux particuliers à l’acheteur et
celuici peut avoir d’autres droits qui varient d’un État à l’autre.
Pour de plus amples informations concernant ses droits,
l’acheteur peut communiquer avec le bureau de la protection du
consommateur local ou de l’État ou le secrétaire à la Justice de
l’État concerné.
GARANTIE LIMITÉE DU PRODUIT
DISPOSITIONS GÉNÉRALES
Aucune garantie ou assurance contenue ou exprimée dans les présen-
tes ne s’appliquera lorsque les dommages ou le besoin de réparations
sont la conséquence d’une ou plusieurs des choses suivantes:
1. Panne d’électricité.
2. Dommages subis au cours du transport ou du déplacement de
l’appareil.
3. Alimentation électrique inappropriée (par exemple, faible tension,
câblage domestique défectueux ou fusibles inadéquats).
4. Accident, modification, mauvaises conditions de fonctionnement
ou mauvaise utilisation de l’appareil, des suites par exemple d’une
circulation inadéquate de l’air dans une pièce ou de conditions de
fonctionnement anormales (températures ambiantes extrême-
ment élevées ou basses).
5. Dommages par le feu ou l’eau, vol, guerre, émeute, hostilités, cas
fortuits comme les ouragans, les inondations, etc.
Pour des renseignements concernant votre garantie, contactez:
Au CANADA
Fantech
50 Kanalflakt Way,
Bouctouche, NB E4S 3M5
Phone: 800.565.3548; 506.743.9500
Fax: 877.747.8116; 506.743.9600
Aux ÉTATS-UNIS continentaux
Fantech
10048 Industrial Blvd.
Lenexa, KS 66215
Phone: 800.747.1762; 913.752.6000
Fax: 800.487.9915; 913.752.6466
Déshumidificateur industriel
Numéro de modèle Numéro de série
Date d’achat Nom du client
Adresse Ville
Acheté chez
12
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
ADVERTENCIA
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
Peligro de Choque Eléctrico
Conecte a un contacto de pared de conexión a tierra de
3 terminales.
No quite la terminal de conexión a tierra.
No use un adaptador.
No use un cable eléctrico de extensión.
No seguir estas instrucciones puede ocasionar la muerte, incen-
dio o choque eléctrico.
Requisitos eléctricos
Para operar el deshumidificador a 115V, es preciso el uso de
un enchufe normal con toma de tierra y circuito de 15 amp.
Es preciso utilizar un interruptor de escape a tierra si la uni-
dad se va utilizar en un área especialmente húmeda.
Sistema integrado de seguridad eléctrica
Para proporcionarle mayor seguridad, este electrodoméstico
está fabricado con una clavija con toma a tierra incluida en
el cable de toma de corriente. El cable debe enchufarse a un
receptáculo de corriente adecuado y con toma a tierra. Un
electricista acreditado deberá instalar un enchufe con toma
de tierra si no dispone de uno. No corte ni elimine la patilla
de toma a tierra de la clavija si ésta viniera incluida en el
equipo. Le recomendamos que el circuito eléctrico o enchufe
opere bajo un cortacircuitos o fusible aparte.
En caso de que necesite un cable de extensión, el cable
deberá contar con conductores de calibre mínimo de 14
gauge si es de 25 pies o más corto, y de calibre 12 gauge
si es más largo de 25 pies (sección de 3.31 y 2.08
milímetros cuadrados respectivamente).
Extracción de agua
El deshumidificador incluye una bomba interna de condensación
que elimina el agua sustraída del aire. Este sistema permite
evacuar el agua hasta a 20 pies de distancia utilizando la
manguera incluida. En caso de que necesite evacuar el agua a
una distancia mayor a 20 pies, deberá instalar otra bomba
capaz de evacuar el agua a partir de este punto. La bomba de
condensación evacua el agua de manera automática cada
cuatro minutos y durante 20 segundos.
FUNCIONAMIENTO
Coloque el deshumidificador en el área en la que quiera reducir
la humedad. Compruebe que las puertas y ventanas esn
cerradas al exterior, y sle la zona meda de cualquier otra
zona no afectada. Introduzca la manguera de condensacn en un
desagüe o en un contenedor de grandes dimensiones. Presione
el interruptor On/Off para activar el deshumidificador. (Fig. 1)
Botón de corriente (Fig. 1)
Puede prender o apagar el deshumidificador
apretando el botón de corriente. El indicador
mostrará la cantidad acumulada de horas de
uso una vez comience a operar.
Botón de la bomba de evacuación (Fig. 2)
En situaciones normales de funciona-
miento, la bomba vaciará el recipiente
contenedor de manera automática.
Puede presionar este botón si desea
evacuarlo de manera manual. La bomba
funciona durante 20 segundos si lo
presiona una vez. Si lo presiona dos veces, operará durante 30
segundos.
No olvide evacuar manualmente todo el agua del
recipiente siempre que vaya a almacenar o transportar el
aparato. Apáguelo y manténgalo conectado durante 5 minutos
antes de evacuar el agua del aparato por última vez.
Contador digital de horas de uso (Fig. 3)
El contador le mostrará la cantidad total de horas acumula-
das de operación con una exactitud de un 1/10 de hora.
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
Fig. 3
Botón de horas (Fig. 4)
Presione el botón HOURS cuando no
pueda enchufar el deshumidificador
pero quiera comprobar el total de
horas acumuladas. El indicador le
mostra durante 10 segundos la
última cantidad guardada.
Cambio de la batería
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
AVERTISSEMENT
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
Peligro De Choque Eléctrico
Desconecte de la toma de corriente antes de sustituir la batería.
No seguir estas instrucciones podría provocar incendios, descar-
gas eléctricas, e incluso la muerte.
Desconecte el deshumidificador de la toma de corriente. El indica-
dor de horas de operación utiliza una batería para que pueda ser
operativo si el aparato no es enchufado y se presiona el botón
de horas. Para cambiar esta batea, tendrá que desatornillar los
cuatro (4) tornillos del panel de instrumentos. Desconecte la
batería agotada y sustitúyala por una nueva. Vuelva a colocar el
panel de instrumentos y los tornillos, sin apretarlos en exceso.
Ciclo de deshielo
Un termistor activa el control electnico y el indicador luminoso
de deshielo cuando existe acumulacn de hielo en los serpentines.
El sistema de medición de temperatura del termistor apaga el
compresor. El ventilador seguirá funcionando, y el aire pasa por
el serpentín de evaporación hasta derretir el hielo. Una vez el hielo
se haya derretido, el termistor finaliza el ciclo de deshielo y se
reiniciará el funcionamiento del compresor.
Indicador de deshielo (Fig. 5)
El indicador de deshielo se ilumina
cuando el deshumidificador esté en un
ciclo de deshielo. El compresor no
funciona durante este periodo.
Fig. 1
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
Fig. 2
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
Fig. 4
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
Fig. 5
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
Déshumidificateur industriel
13
Déshumidificateur industriel
Ventilación / tubos de
ventilación (Fig. 6)
El aparato cuenta con dos orifi-
cios que permiten la instalación
de dos tubos individuales de 5
pulgadas (12.7 cm.), o de uno
solo de 10 pulgadas plano (25.4
cm.). De este modo se
puede dirigir el aire caliente
a zonas diferentes.
MANTENIMIENTO
Filtro del aire (Fig. 7)
Debe comprobar el estado del filtro del aire con frecuencia.
Si opera el deshumidificador con un filtro taponado reducirá
su eficiencia. Puede pasar una aspiradora por el filtro para
eliminar el polvo. Para acceder al medio del filtro, deslice el
marco del filtro hacia arriba hasta extraerlo por completo del
aparato. Quite el medio del filtro de la parte trasera del
marco y pase una aspiradora. Haga el proceso a la inversa
para instalar el filtro y el marco en el deshumidificador.
LIMPIEZA
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
ADVERTENCIA
Built in Electrical Safety
For your safety and protection this appliance is manufactured
with a grounded plug on its power cord. The power cord must
be plugged into a properly grounded receptacle. If a ground-
ed receptacle does not exist, have one installed by a certified
electrician. Do not cut or remove the grounding prong on the
power cord plug if equipped. We recommend that this electri-
cal circuit/receptacle operate under a separate breaker or
fuse.
If an extension cord is required, it must have a minimum of
14 gauge conductors if 25 feet long or less and 12 gauge
conductors if greater than 25 feet long.
Electrical Requirements
For 115V operation, a common grounded outlet on a 15 amp
circuit is required. The dehumidifier draws approx. 8 amps at
80°F, 60% RH. If used in a wet area, a ground fault inter-
rupter (GFI) is required.
Power Button (Fig. 1)
The dehumidifier is turned on or off by
pressing the power button. When the
dehumidifier is started, the hour meter will
display the cumulative hours.
Pump Purge Button (Fig. 2)
In normal operation, the pump will automat-
ically empty the reservoir. Pressing this but-
ton allows manual emptying of the reservoir.
Press once, and the pump will operate for
20 seconds. Press and hold the button and
the pump will activate for 30 seconds.
Always manually purge the water reservoir
before transport or storage. Turn off the
power and allow the plugged in dehumidifier
to rest 5 minutes before the final purge.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Place dehumidifier inside area to be dried. Make sure all win-
dows and doors are closed to the outside and seal off the wet
area from any unaffected areas. Route condensate hose into
a drain, or a very large container. Press the On/Off button
(Fig. 1) to activate the dehumidifier.
OPERATION
Fig. 1
Fig. 2
Digital Hour Counter (Fig. 3)
The counter will accumulate and display the total running hours
of the unit in 1/10 of an hour.
Hour Button (Fig. 4)
Press the HOURS button when the dehu-
midifier cannot be plugged in and the hour
meter needs to be read. The digital hour
meter will display the last saved cumulative
time for ten seconds.
Defrost Indicator (Fig. 5)
The defrost indicator will light to indicate the
dehumidifier is in defrost cycle. During this
period, the compressor is not running.
Defrost Cycle
When ice builds up on the coils, a thermistor activates the elec-
tronic control and defrost light. The compressor is turned off by
the thermistor temperature measurement. The blower will contin-
ue to run, causing air to flow through the evaporator coil and melt
the ice. When the ice is melted, the thermistor will end the defrost
cycle and the compressor will be started.
Disconnect dehumidifier from power supply. The hour meter uses
a battery backup for display when the dehumidifier is unplugged
and the hour button is depressed. To change the battery, it is nec-
essary to remove the four (4) screws from the control panel.
Disconnect the old battery and replace with new battery. Replace
control panel and screws. Do not overtighten screws.
Water Removal
The dehumidifier is equipped with an internal condensate pump
to remove the water that is collected from the air. This allows the
water to be pumped 20 feet with the attached hose. If the water
needs to be pumped more than 20 feet above the unit, a second
pump must be added to relay the water. The condensate pump
automatically purges for 20 seconds every four minutes.
Fig. 3
Fig. 4
Fig. 5
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Battery Replacement
(1)
Peligro de Choque Eléctrico
Desconecte la toma de corriente antes de limpiar.
No seguir estas instrucciones podría provocar incendios, descar-
gas eléctricas, e incluso la muerte..
Limpieza del exterior
Utilice una solución de jabón suave, no abrasivo ni inflamable y agua
limpia para limpiar el deshumidificador. Pase un trapo para secarlo.
Nettoyage interne
Desconecte el deshumidificador de la toma de corriente.
Limpieza ligera:
Saque el aire del filtro y roe el serpentín
evaporador con agua. Desatornille los dos tornillos de la parte
superior de la cubierta frontal.
Limpieza profunda: Desatornille los dos tornillos de la parte superior
de la cubierta frontal. Abra la cubierta. Rocíe los serpentines con
agua. Cierre la cubierta y vuelva a colocar los tornillos (Fig. 8))
Fig. 8
Maintenance
Air Filter (Fig. 7)
The air filter should be checked regularly. Operating the dehu-
midifier with a clogged filter will reduce efficiency. The filter can be
vacuum cleaned to remove dust. To access the filter media, slide
the filter frame up until it clears the dehumidifier cabinet. Remove
the filter media from behind the frame and vacuum. Reverse pro-
cedure to re-install the filter and frame into the dehumidifier.
Storage
Freezing temperatures and biological growth must be considered
before storing the dehumidifier. The dehumidifier should be
flushed with a biofungicide before storing. When storing the unit,
ensure that water has been removed from the reservoir and
hose. This will prevent damage caused by freezing temperatures
and to prevent biological growth. Use the pump purge button to
remove water and biofungicide chemicals from the dehumidifier.
Stacking (Fig.9)
The dehumidifiers can be stacked on top of each other. The
wheels from the upper unit must be resting in the cradle of
the lower unit. DO NOT STACK MORE THAN TWO HIGH.
External Cleaning
Use a non-flammable mild, non-abrasive soap and clean
water solution to clean the dehumidifier. Wipe dry.
Internal Cleaning
Disconnect dehumidifier from power supply.
Light cleaning: Remove the air filter and spray evaporator
coil with water.Remove the two upper screws from the front
hood.
Heavy cleaning: Remove two upper screws from front hood.
Open hood. Spray water at coils. Close hood and replace
screws. (Fig. 8)
Fig. 7
Fig. 8
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before cleaning.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Venting / Ducting (Fig. 6)
Twin rear outlets can accommo-
date two individual 5” ducts or one
10” lay flat duct to be attached.
This allows for warm dry air to be
directed into different areas.
Fig. 6
Cleaning
Fig. 9
Service
A qualified refrigeration technician must service all refriger-
ant leaks.
WARNING: The dehumidifier uses a high pressure refrigerant
system and high voltage circuitry which could present a health
hazard resulting in death, serious bodily injury, and/or property
damage. Only qualified service people should service this unit.
CAUTION: Do not operate unit without the front hood secured in
place.
The serial data plate is located on the underside of the dehumid-
ifier. For service information contact 1-800-565-3548.
(2)
Almacenamiento
Considere posibles condiciones de congelación o de formación de
microorganismos antes de plantearse el almacenamiento del
deshumidificador. Debea rociar el deshumidificador con un bio-
fungicida antes de almacenarlo. Recuerde que debe comprobar
que todo el agua ha sido extraída del recepculo y de la
manguera para evitar dos producidos por temperaturas bajo
cero y para prevenir formación de microorganismos. Utilice el
botón de la bomba de evacuacn para extraer el agua y químicos
biofungicidas del aparato.
Colocación en vertical (Fig. 9)
Puede apilar los deshumidificadores uno encima del otro. Las rue-
das de la unidad que se coloque encima deberán apoyarse en los
huecos de la unidad colocada abajo. NO APILE MÁS DE DOS UNIDADES
Fig. 9
Servicio
En caso de que se produzca una fuga de líquido refrigerante
deberá contactar con un técnico cualificado en refrigeración.
ADVERTENCIA: El deshumidificador utiliza un sistema de quido
refrigerante de alta presn y un circuito ectrico de alto voltaje
que podan resultar en dos materiales, peligro para la salud,
lesiones corporales graves, e incluso la muerte. lo personal
cualificado debe dar servicio a esta unidad.
PRECAUCIÓN: No utilice la unidad hasta haber asegurado la
cubierta frontal en posición cerrada.
La placa serial está situada en el superficie inferior del
deshumidificador. Consulte con el número 1-800-565-3548
para másinformación sobre servicio.
Maintenance
Air Filter (Fig. 7)
The air filter should be checked regularly. Operating the dehu-
midifier with a clogged filter will reduce efficiency. The filter can be
vacuum cleaned to remove dust. To access the filter media, slide
the filter frame up until it clears the dehumidifier cabinet. Remove
the filter media from behind the frame and vacuum. Reverse pro-
cedure to re-install the filter and frame into the dehumidifier.
Storage
Freezing temperatures and biological growth must be considered
before storing the dehumidifier. The dehumidifier should be
flushed with a biofungicide before storing. When storing the unit,
ensure that water has been removed from the reservoir and
hose. This will prevent damage caused by freezing temperatures
and to prevent biological growth. Use the pump purge button to
remove water and biofungicide chemicals from the dehumidifier.
Stacking (Fig.9)
The dehumidifiers can be stacked on top of each other. The
wheels from the upper unit must be resting in the cradle of
the lower unit. DO NOT STACK MORE THAN TWO HIGH.
External Cleaning
Use a non-flammable mild, non-abrasive soap and clean
water solution to clean the dehumidifier. Wipe dry.
Internal Cleaning
Disconnect dehumidifier from power supply.
Light cleaning: Remove the air filter and spray evaporator
coil with water.Remove the two upper screws from the front
hood.
Heavy cleaning: Remove two upper screws from front hood.
Open hood. Spray water at coils. Close hood and replace
screws. (Fig. 8)
Fig. 7
Fig. 8
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
WARNING
Disconnect power supply before cleaning.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Venting / Ducting (Fig. 6)
Twin rear outlets can accommo-
date two individual 5” ducts or one
10” lay flat duct to be attached.
This allows for warm dry air to be
directed into different areas.
Fig. 6
Cleaning
Fig. 9
Service
A qualified refrigeration technician must service all refriger-
ant leaks.
WARNING: The dehumidifier uses a high pressure refrigerant
system and high voltage circuitry which could present a health
hazard resulting in death, serious bodily injury, and/or property
damage. Only qualified service people should service this unit.
CAUTION: Do not operate unit without the front hood secured in
place.
The serial data plate is located on the underside of the dehumid-
ifier. For service information contact 1-800-565-3548.
(2)
Fig. 6
Fig. 7
14
GARANTÍA DE UN AÑO
Se garantiza este producto contra defectos de fabricación y materiales
por un periodo de un año a contar a partir de la fecha de compra del
comprador original. Todas las partes y la mano de obra estarán cubi-
ertas sin coste alguno durante este periodo. Las partes de reemplazo
habitual (bombillas y filtros, por ejemplo), no están cubiertas por la
garantía ni se garantizan durante periodo de tiempo alguno. Esta
garantía no puede transferirse.
GARANTÍA ADICIONAL DE SEIS AÑOS
Durante un periodo de seis años a contar desde la finalización de la
GARANTÍA DE UN AÑO, los componentes del sistema precintado
están cubiertos en caso de que las piezas mostraran algún defecto. Se
entregarán las piezas de manera gratuita (tras prepago de costos de
envío). Los costes de mano de obra para la instalación no están cubi-
ertos por la garantía. Esta garantía no puede transferirse.
GARANTÍA DE POR VIDA EN LA CAJA ROTOMOLDEADO
La caja rotomoldeado de este producto cuenta con una garantía de por
vida. Esta garantía no es transferible.
AVISO
1. Esta garantía es válida solamente para el comprador original y
dentro de las fronteras de Canadá y la parte continental de
Estados Unidos.
2. Esta es la única garantía del vendedor y de Fantech Limited para
el producto mencionado arriba. Ningún otro tipo de garantía o
condición, explícita o implícita, será aplicable, excepto en casos
específicamente excluidos por ley.
3. El comprador original deberá completar el formulario de garantía
y conservarlo para poder utilizarlo en caso de que sea preciso dar
servicio al producto.
4. Para cualquier reclamación de garantía será preciso contar con
una prueba de compra con fecha. Recuerde guardar el recibo
como comprobante de venta.
5. En algunos estados no se permite la exclusión o limitación de
daños consecuentes o secundarios; en estos casos, la limitación
anterior podría no aplicar a su caso. Esta garantía ofrece dere-
chos legales específicos; el comprador puede contar con otros
diferentes dependiendo del estado. Si necesita más información
sobre los derechos legales del comprador, puede consultar con la
oficina del consumidor local o estatal, o con el fiscal de su estado.
GARANTÍA LIMITADA DE PRODUCTO
PROVISIONES GENERALES
La garantía o seguro contenidos o establecidos aquí no serán aplica-
bles cuando el daño o la reparación consecuentes sean resultado
de alguno de los siguientes:
1. Fallo del suministro eléctrico.
2. Daños durante el transporte o traslado del electrodoméstico.
3. Suministro eléctrico inadecuado del tipo voltaje bajo, cableado
deficiente en la casa o fusibles no adecuados.
4. Accidente, alteración, abuso o mal uso del electrodoméstico del
tipo circulación de aire inadecuado en el cuarto, o condiciones
anormales de operación (temperaturas demasiado altas o
demasiado bajas en el cuarto).
5. Fuego, agua, daño, robo, guerra, disturbios, hostilidades, casos
de fuerza mayor del tipo huracanes, inundaciones, etc.
Para obtener información relativa a la garantía, comuníquese con:
En CANADA
Fantech
50 Kanalflakt Way,
Bouctouche, NB E4S 3M5
Phone: 800.565.3548; 506.743.9500
Fax: 877.747.8116; 506.743.9600
En Estados Unidos continental
Fantech
10048 Industrial Blvd.
Lenexa, KS 66215
Phone: 800.747.1762; 913.752.6000
Fax: 800.487.9915; 913.752.6466
Deshumidificador industrial
Número del modelo Número de serie
Fecha de compra Nombre del cliente
Adresse Ciudad
Comprado en
15
16
Item #: 405037
Rev Date: 071111
Fantech reserves the right to modify, at any time and without notice,
any or all of its products’ features, designs, components and specifica-
tions to maintain their technological leadership position.
United States
10048 Industrial Blvd.
Lenexa, KS 66215
Phone: 800.747.1762; 913.752.6000
Fax: 800.487.9915; 913.752.6466
www.fantech.net; [email protected]
Canada
50 Kanalflakt Way,
Bouctouche, NB E4S 3M5
Phone: 800.565.3548; 506.743.9500
Fax: 877.747.8116; 506.743.9600
Distributed by:
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Fantech EDP150LR Le manuel du propriétaire

Catégorie
Déshumidificateurs
Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues