GE DSKS433EBWW Guide d'installation

Taper
Guide d'installation
MATERIALS YOU WILL NEED
WARNING RISK OF FIRE
To reduce the risk of severe injury or death, follow all installation
instructions.
&ORWKHV GU\HU LQVWDOODWLRQ PXVW EH SHUIRUPHG E\ D TXDOL¿HG
installer.
Install the clothes dryer according to these instructions and
in accordance with local codes. In the absence of local codes,
installation must comply with the NATIONAL ELECTRICAL
CODE, ANSI/NFPA NO. 70.
This dryer must be exhausted to the outdoors.
Use only 4” rigid metal ducting for exhausting the clothes dryer to
the outdoors.
'2 127 LQVWDOO D FORWKHV GU\HU ZLWK ÀH[LEOH SODVWLF GXFWLQJ
PDWHULDOV ,I ÀH[LEOH PHWDO VHPLULJLG RU IRLOW\SH GXFW LV
installed, it must be UL listed and installed in accordance with
the instructions found in “Connecting The Dryer To House Vent”
on page 4 of this manual. Flexible venting materials are known
to collapse, be easily crushed, and trap lint. These conditions will
REVWUXFWGU\HUDLUÀRZDQGLQFUHDVHWKHULVNRI¿UH
Do not install or store this appliance in any location where it
could be exposed to water and or weather.
6DYH WKHVH LQVWUXFWLRQV ,QVWDOOHUV %H VXUH WR OHDYH WKHVH
LQVWUXFWLRQVZLWKWKHFXVWRPHU
DETERMINE ELECTRICAL REQUIREMENTS FOR YOUR DRYER MODEL
7KLVGU\HUPXVWEHFRQQHFWHGWRDQLQGLYLGXDOEUDQFKFLUFXLWRISURSHUYROWDJHDQGIUHTXHQF\DVVSHFL¿HGRQ5DWLQJ3ODWHORFDWHGLQVLGH
GU\HUGRRUZLWKQRRWKHUDSSOLDQFHVRU¿[WXUHVDWWDFKHG
(;&(37,21
$ 9UHFHSWDFOH LV ORFDWHG RQWKHEDFNRQWKHGU\HU DQG LV DYDLODEOH RQO\ IRU XVH ZLWK DZDVKHUWKDW LV DȻ[HG WR WKH GU\HU ZLWK D
:')NLW,WPD\QRWEHXVHGIRUDQ\RWKHUDSSOLDQFHRUDQ\FRQGLWLRQVRWKHUWKDQVWDWHGDERYH99PRGHOVRQO\
%UDQFKFLUFXLWPXVWEHSURWHFWHGE\WKHUHTXLUHGWLPHGHOD\IXVHVRUFLUFXLWEUHDNHUV9RU9LQVWDOODWLRQDPSV9LQVWDOODWLRQRUDPSV
The electrical installation must conform to the national and local codes.
208V AND 240V MODELS ARE NOT APPROVED FOR 120V INSTALLATION.
Installation Instructions (USA only)
MODELS DSKS433 AND DSKS333 MUST BE INSTALLED WITH CONTROL PANEL AT BOTTOM IN ORDER TO OPERATE ADEQUATELY.
UNPACKING AND PREPARING FOR INSTALLATION
Prepare the area and exhaust for installation of new dryer.
&KHFNDQGHQVXUHWKHH[LVWLQJH[WHUQDOH[KDXVWLVFOHDQDQGPHHWVDWWDFKHGLQVWDOODWLRQVSHFL¿FDWLRQV
Remove the literature and accessories bag from the dryer drum. Place the literature in a convenient place.
Using foam pads from dryer carton, turn dryer upside down as shown.
Install knobs. For location, refer to the Owner’s Manual.
Dryer is now ready to be mounted above washer using accessory kit.
Remove the foam shipping pads from under dryer.
Move the dryer to the desired location.
Follow the steps in the following pages to connect the dryer to the external exhaust and power supply.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT- Save these instructions for local
inspector’s use.
IMPORTANT- Observe all governing codes and
ordinances.
Note to Installer -%HVXUHWROHDYHWKHVHLQVWUXFWLRQV
with the customer.
Note to Customer - Keep these instructions with your
Owner’s Manual for future reference.
%HIRUH WKH ROG GU\HU LV UHPRYHG IURP VHUYLFH RU
discarded, remove the dryer door.
Service information and the wiring diagram are located
in the control console.
Do not allow children on or in the appliance. Close
supervision of children is necessary when the appliance
is used near children.
,QVWDOOWKHGU\HUZKHUHWKHWHPSHUDWXUHLV DERYH)
for satisfactory operation of the dryer control system.
Product failure due to improper installation is not
covered under the Warranty.
'U\HUV LQVWDOOHG LQ JDUDJHV LI DOORZHG E\ ORFDO FRGHV
PXVWEHHOHYDWHGLQFKHVFPDERYHWKHÀRRU
TOOLS YOU WILL NEED
SLIP JOINT PLIERS
FLAT BLADE AND PHILLIPS SCREWDRIVER
S
GLOVES
SAFETY
GLASSES
DRYER POWER
CORD KIT
(NOT PROVIDED
WITH DRYER)
4" DUCT
CLAMPS (2)
OR
4" SPRING
CLAMPS (2)
EXHAUST
HOOD
3/4" STRAIN
RELIEF
UL RECOGNIZED
4" DIA. METAL
ELBOW
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. METAL DUCT (RECOMMENDED)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT
(IF NEEDED.)
DUCT TAPE
UL RATED
120/240V,30A
WITH 3 OR 4 PRONGS.
IDENTIFY THE PLUG
TYPE AS PER THE
HOUSE RECEPTACLE
BEFORE PURCHASING
LINE CORD.
234D2017P001 31-16710 02-13 GE
STACKING KITS FOR DRYERS
(Comes with individual Installation Instructions)
 Over washer
- Use Wall Mount Kit WMK-35 or
- Stack Rack DSDR24 or
- Stack Rack DSR-24
 For alcove and closet depth and width
UHTXLUHPHQWVVHHVSHFL¿FNLWLQVWUXFWLRQV
 All stacking kits are available from your
local sales outlet.
Questions? Call: 800.GE.CARES (US) or visit our web site at: www.GEAppliances.com (US)
Printed in Mexico
FOR THREE-WIRE SUPPLY
(208V & 240V MODELS)
Remove terminal block cover.
&RQQHFWWZR+27OLQHVWRRXWHUVFUHZV/DQG/RI
terminal block.
Connect Neutral line to center
VFUHZ1RIWHUPLQDOEORFN
Properly strain relief the cordset or cable to the cable entry
hole with UL recognized strain relief.
Replace terminal block cover.
FOR FOUR-WIRE SUPPLY
(208V & 240V MODELS)
Remove terminal block cover.
5HPRYHJURXQGVWUDSDQGGLVFDUG5HVFUHZJUHHQ
grounding screw in place.
&RQQHFWWZR+27OLQHVWRRXWHUVFUHZV/DQG/RI
terminal block.
&RQQHFW1HXWUDOOLQHWRFHQWHUVFUHZ1RIWHUPLQDOEORFN
Attach ground wire of power
supply to green grounding screw
beside terminal block.
Properly strain relief the cordset or cable to the cable
entry hole with UL recognized strain relief.
Replace terminal block cover.
Typical 30 amp receptacle for use where
local codes permit use of flexible type
power supply cord (pigtail).
3 WIRE RECEPTACLE
(10-30R)
7KH RSHUDWLQJ YROWDJH 9ROWV $PSHUDJH $PSV DQG
)UHTXHQF\ +] RI WKLV GU\HU DUH LQGLFDWHG RQ WKH 5DWLQJ
Plate located to the right of the loading port.
Connect this dryer to a circuit corresponding to that
indicated on Rating Plate and protected by fuses or a
circuit breaker in accordance with local codes.
Use a power supply cord kit marked for use with clothes
GU\HU)RU9DQG9PRGHOVXVHDSRZHUVXSSO\FRUG
kit marked for use with clothes dryers.
)RUDOWHUQDWH9RU9SRZHUVXSSO\KRRNXSSURFHHG
DVIROORZV
Connect supply wire leads to terminal block as shown on
sketch below, depending on type of installation.
Make sure screws on terminal block are tight.
This appliance must be grounded. In the event of malfunction
or breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electrical current.
WARNING: Improper connection of the
equipment grounding conductor can result in a risk of electric
VKRFN&KHFNZLWKDTXDOL¿HGHOHFWULFLDQRUVHUYLFHPDQLI\RX
are in doubt as to whether the appliance is properly grounded.
'RQRWPRGLI\WKHSOXJSURYLGHGZLWKWKHDSSOLDQFHLILWZLOOQRW¿W
WKHRXWOHWKDYHDSURSHURXWOHWLQVWDOOHGE\DTXDOL¿HGHOHFWULFLDQ
WARNING: Appliance grounded to neutral
conductor through a link. If used in a mobile home, a new
construction, a recreational vehicle or if local codes do not
SHUPLWJURXQGLQJWKURXJKQHXWUDODFRQGXFWRUFRUGRUFDEOH
assembly for use with clothes dryers must be used with the
IROORZLQJ VSHFL¿FDWLRQV 7\SH 6W &DEOH  0LQ 9ROW
 $PS ZLWK FORVHGORRS WHUPLQDOV DQG VHFXUHG ZLWK D 8/
recognized strain relief. See manufacturer’s instructions.
2
ELECTRICAL CONNECTION DETAILS
OBSERVE ALL GOVERNING CODES AND ORDINANCES
DO NOT USE EXTENSION CORD WITH THIS APPLIANCE
GROUNDING INSTRUCTIONS
POWER SUPPLY
&25'$:*
MINIMUM COPPER
CONDUCTORS
$039
WITH TYPE UL
5(&2*1,=('
MINIMUM RATED
&
2592/7
23(5$7,21
OR 120/240 VOLT
6833/<86(21/<
$03)86(6
POWER SUPPLY CORD
$:*0,1,080
&233(5&21'8&7256
$039:,7+&/26('
LOOP TERMINALS TYPE UL
5(&2*1,=('0,1,080
5$7('&
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.
5(029(*5281'675$3
$1'',6&$5'25
92/723(5$7,2125
92/76833/<86(
21/<$03)86(6
Typical 30 amp receptacle for use
where local codes permit use of
flexible type power supply cord
(pigtail).
Typical 30 amp cord assembly for
use where local codes do not
permit grounding through neutral.
4-WIRE RECEPTACLE (14-30R)
4-CONDUCTOR CORD
ASSEMBLY ( Type ST Cable)
X
W
G
Y
*UHHQRU<HOORZ
*URXQG:LUH
Hot Wire
*UHHQ
*URXQGLQJ
Screw
*URXQG
Strap
White Neutral Wire
Hot Wire
*UHHQ*URXQGLQJ6FUHZ
Hot
Wire
White Neutral Wire
Hot
Wire
DRYER TOP VIEW
IF YOUR DRYER COMES WITH REAR EXHAUST,
TO CHANGE TO SIDE OR BOTTOM EXHAUST:
Remove access panel at back of dryer to gain access
to internal ducts.
Disconnect duct exhaust from blower housing
UHPRYHWDSHVHFXULQJGXFW
FOR SIDE EXHAUST:
5HPRYHGHVLUHGNQRFNRXWSODWHHLWKHUULJKWRUOHIWVLGH
&XWDPPòµOHQJWKRIPPµGLDULJLG
GXFWDVVKRZQUHPRYHEXUUVIURPFXWHGJH
Attach this extension duct to blower housing duct.
$WWDFKDHOERZIDFLQJGHVLUHGRSHQLQJ
$WWDFKDVHFWLRQRIPPµGLDULJLGGXFW
to elbow to protrude through side of cabinet.
Seal all joints with duct tape.
Reinstall rear access panel.
FOR BOTTOM EXHAUST:
Remove cover plate at bottom of dryer.
,QVWDOODHOERZ
Seal all joints with duct tape.
Reinstall rear access panel.
3ODFHFRYHUSODWHUHPRYHGIURPERWWRP
RIGU\HURYHUUHDUH[KDXVWRSHQLQJ
IF YOUR DRYER COMES WITH TOP EXHAUST,
TO CHANGE TO SIDE OR REAR EXHAUST:
Remove rear access panel.
'LVFRQQHFW UHWDLQLQJSODWH DQG HOERZE\ UHPRYLQJ
mounting screw from the chassis and remove tape
securing elbow to blower housing.
Remove cover plate from rear access panel and place
over top exhaust opening.
FOR SIDE EXHAUST:
5HPRYHGHVLUHGNQRFNRXWSODWHHLWKHUULJKWRUOHIWVLGH
7DNH WKH GXFW SUHYLRXVO\ UHPRYHG DQG FXW D  PP
 òµ OHQJWK RI  PP µ GLD ULJLG GXFW DV VKRZQ
UHPRYHEXUUVIURPFXWHGJH
Attach this extension duct to blower housing duct.
$WWDFKWKHHOERZIDFLQJGHVLUHGRSHQLQJ
$WWDFKDVHFWLRQRIPPµGLDULJLGGXFWWRHOERZWR
protrude through side of cabinet.
Seal all joints with duct tape.
Reinstall rear access panel.
FOR REAR EXHAUST:
&XWDPPò´OHQJWKRIPPµGLDULJLG
GXFWDVVKRZQUHPRYHEXUUVIURPFXWHGJH
Attach this extension duct to blower housing.
Seal all joints with duct tape. Reinstall near access panel.
EXHAUST INFORMATION
WARNING - IN CANADA AND IN THE
UNITED STATES, THE REQUIRED EXHAUST DUCT
DIAMETER IS 4 in (102mm). DO NOT USE DUCT LONGER
THAN SPECIFIED IN THE EXHAUST LENGTH TABLE.
8VLQJH[KDXVWORQJHUWKDQVSHFL¿HGOHQJWKZLOO
• Increase the drying times and the energy cost.
• Reduce the dryer life.
$FFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG
WARNING - BEFORE PERFORMING THIS
EXHAUST INSTALLATION, BE SURE TO DISCONNECT
THE DRYER FROM ITS ELECTRICAL SUPPLY.
The correct exhaust installation is YOUR RESPONSIBILITY. Problems
due to incorrect installation are not covered by the warranty.
Remove and discard existing plastic or metal foil transition duct and
UHSODFHZLWK8/OLVWHGWUDQVLWLRQGXFW
The MAXIMUM ALLOWABLE duct length and number of bends of the
exhaust system depends upon the type of duct, number of turns, the
W\SHRIH[KDXVWKRRGZDOOFDSDQGDOOFRQGLWLRQVQRWHGEHORZ7KH
maximum duct length for rigid metal duct is shown in the table on
the next page.
EXHAUST SYSTEM CHECK LIST
HOOD OR WALL CAP
Terminate in a manner to prevent back drafts or entry of birds or
other wildlife.
Termination should present minimal resistance to the exhaust
DLU ÀRZ DQG VKRXOG UHTXLUH OLWWOH RU QR PDLQWHQDQFH WR SUHYHQW
clogging.
Never install a screen in or over the exhaust duct. This could cause
lint build up.
Wall caps must be installed at least 12 in. above ground level or any
other obstruction with the opening pointed down.
SEPARATION OF TURNS
For best performance, separate all turns by at least 4 ft. of straight
duct, including distance between last turn and exhaust hood.
TURNS OTHER THAN 90º
 2QHWXUQRIRUOHVVPD\EHLJQRUHG
 7ZRWXUQVVKRXOGEHWUHDWHGDVRQHWXUQ
 (DFKWXUQRYHUVKRXOGEHWUHDWHGDVRQHWXUQ
SEALING OF JOINTS
All joints should be tight to avoid leaks. The male end of each
section of duct must point away from the dryer.
The duct shall not be assembled with screws or other fastening
means that extend into the duct and catch lint.
 'XFWMRLQWVFDQEHPDGHDLUDQGPRLVWXUHWLJKWE\ZUDSSLQJWKH
overlapped joints with duct tape.
Horizontal runs should slope down toward the outdoors
1/4 inch
per foot.
INSULATION
Ductwork that runs through an unheated area or is near air conditioning
VKRXOGEHLQVXODWHGWRUHGXFHFRQGHQVDWLRQDQGOLQWEXLOGXS
EXHAUST CONNECTION
WARNING - TO REDUCE THE RISK OF
FIRE OR PERSONAL INJURY:
This clothes dryer must be exhausted to the outdoors.
Use only 4” rigid metal ducting for the home exhaust duct.
8VHRQO\µULJLG PHWDO RU 8/OLVWHG ÀH[LEOH PHWDOVHPLULJLGRU
IRLOW\SH GXFW WR FRQQHFW WKHGU\HU WR WKH KRPH H[KDXVW GXFW
It must be installed in accordance with the instructions found in
“Connecting the Dryer to House Vent” on page 4 of this manual.
Do not terminate exhaust in a chimney, a wall, a ceiling, gas
YHQWFUDZOVSDFHDWWLFXQGHUDQHQFORVHGÀRRURULQDQ\RWKHU
concealed space of a building. The accumulated lint could create
DSRWHQWLDO¿UHKD]DUG
Never terminate the exhaust into a common duct with a kitchen
exhaust system. A combination of grease and lint creates a
SRWHQWLDO¿UHKD]DUG
'RQRWXVHGXFWORQJHUWKDQVSHFL¿HGLQWKHH[KDXVWOHQJWKWDEOH
/RQJHUGXFWVFDQDFFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG
Never install a screen in or over the exhaust duct. This will cause
OLQWWRDFFXPXODWHFUHDWLQJDSRWHQWLDO¿UHKD]DUG
• Do not assemble ductwork with any fasteners that extend into the
duct. These fasteners can accumulate lint, creating a potential
¿UHKD]DUG
Do not obstruct incoming or exhausted air.
Provide an access for inspection and cleaning of the exhaust
system, especially at turns and joints. Exhaust system shall be
inspected and cleaned at least once a year.
ALTERNATE EXHAUST INSTRUCTIONS
Left knockout
Bottom
knockout
Right knockout
Blower
Front of dryer
152
mm
203 mm
(8”)
89 mm
(3½”)
6”
For Rear Exhaust
For Side Exhaust
Rigid
Metallic
Ducting
Cut Here
EXTENSION DUCT
It is importat to replace the ground clip after
cuttin
g
the exhaust duct,
(
on rear exhaust model
)
295 mm
115 mm (4½”)
(11½”)
EXHAUST LENGTH CALCULATION
RIGID (Preferred)
3DUWVDUHDYDLODEOHIURP\RXUORFDOVHUYLFHRUJDQL]DWLRQ
:;;µ;·'XFW :;;(OERZ
:;;µ;·'XFW :;;$OXPLQXPKRRG
4
ALCOVE OR CLOSET INSTALLATION
If your dryer is approved for installation in an alcove or closet,
it will be stated on a label on the dryer back. The installation
PXVWFRQIRUPWRWKHIROORZLQJVSHFL¿FDWLRQV
WARNING: TO PREVENT LARGE AMOUNTS
OF LINT AND MOISTURE FROM ACCUMULATING AND TO
MAINTAIN DRYER EFFICIENCY, THIS MACHINE MUST BE
EXHAUSTED OUTDOORS.
Minimum clearances between dryer cabinet and adjacent
ZDOOVRURWKHUVXUIDFHVDUH
0LQLPXP YHUWLFDO VSDFH IURP ÀRRU WR RYHUKHDG FDELQHWV
FHLOLQJHWFLVLQ
Closet doors must be louvered or otherwise ventilated and must
FRQWDLQDWOHDVWVTXDUHLQFKHVRIRSHQDUHDHTXDOO\GLVWULEXWHG,I
the closet contains both a washer and a dryer, doors must contain
at least 120 square inches of open area equally distributed.
NOTE TO INSTALLER - AFTER INSTALLATION CHECK
THE FOLLOWING:
(;+$867'8&70XVWPHHWVSHFVRQSDJH1RH[FHVVLYH
WXUQV1RNLQNVRUREVWUXFWLRQVWRDLUÀRZ
(;+$867+22'6KRXOGZRUNIUHHO\DQGRSHQGRZQZDUG
*5281',1*'U\HUPXVWEHSURSHUO\JURXQGHGWRFRQIRUPWR
local codes and ordinance requirements.
23(5$7,217XUQGU\HURQDQGFKHFNIRUKHDW
+$1'&86720(57+(2:1(5·60$18$/*LYHLQVWUXFWLRQVRQ
RSHUDWLQJWKHGU\HU$QVZHUDQ\TXHVWLRQV
*,9(7+(6(,167$//$7,21,16758&7,216WRWKHFXVWRPHU
4" DIA.
4"
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90°
Elbows
Rigid
Metal
Rigid
Metal
14 m (46 ft)
11 m (37 ft)
9 m (30 ft)
7 m (23 ft)
11 m (37 ft)
9 m (30 ft)
6.5 m (22 ft)
4.5 m (15 ft)
0
1
2
3
Use only for short
run installations
CONNECTING THE DRYER TO HOUSE VENT
RIGID METAL TRANSITION DUCT
• For best drying performance, a rigid metal transition duct is
recommended.
• Rigid metal transition ducts reduce the risk of crushing and
kinking.
UL-LISTED FLEXIBLE METAL (SEMI-RIGID) TRANSITION DUCT
,IULJLGPHWDOGXFWFDQQRWEHXVHGWKHQ8/OLVWHGÀH[LEOHPHW
DOVHPLULJLGGXFWLQJFDQEHXVHG.LW:;;
 1HYHU LQVWDOO ÀH[LEOH PHWDO GXFW LQ ZDOOV FHLOLQJV ÀRRUV RU
other enclosed spaces.
7RWDOOHQJWKRIÀH[LEOHPHWDOGXFWVKRXOGQRWH[FHHGIHHW
P
• For many applications, installing elbows at both the dryer
DQGWKHZDOOLVKLJKO\UHFRPPHQGHGVHHLOOXVWUDWLRQVEHORZ
Elbows allow the dryer to sit close to the wall without kinking
and or crushing the transition duct, maximizing drying
performance.
• Avoid resting the duct on sharp objects.
UL-LISTED FLEXIBLE METAL (FOIL-TYPE) TRANSITION DUCT
• In special installations, it may be necessary to connect the
GU\HUWRWKHKRXVHYHQWXVLQJDÀH[LEOHPHWDOIRLOW\SHGXFW
$ 8/OLVWHG ÀH[LEOH PHWDO IRLOW\SH GXFW PD\ EH XVHG 21/<
LQLQVWDOODWLRQVZKHUHULJLGPHWDORUÀH[LEOHPHWDOVHPLULJLG
ducting cannot be used AND where a 4” diameter can be
maintained throughout the entire length of the transition duct.
,Q&DQDGDDQGWKH8QLWHG6WDWHVRQO\WKHÀH[LEOHPHWDOIRLO
W\SH GXFWV WKDW FRPSO\ ZLWKWKH´2XWOLQHIRU &ORWKHV 'U\HU
7UDQVLWLRQ'XFW6XEMHFW$µVKDOOEHXVHG
 1HYHU LQVWDOO ÀH[LEOH PHWDO GXFW LQ ZDOOV FHLOLQJV ÀRRUV RU
other enclosed spaces.
7RWDOOHQJWKRIÀH[LEOHPHWDOGXFWVKRXOGQRWH[FHHGIHHW
P
• Avoid resting the duct on sharp objects.
For best drying performance
1 Slide one end of the duct over the clothes dryer outlet pipe.
2. Secure the duct with a clamp.
:LWKWKHGU\HULQLWVSHUPDQHQWSRVLWLRQH[WHQGWKHGXFWWR
its full length. Allow 2” of duct to overlap the exhaust pipe.
&XWRȺDQGUHPRYHH[FHVVGXFW.HHSWKHGXFWDVVWUDLJKWDV
SRVVLEOHIRUPD[LPXPDLUÀRZ
4. Secure the duct to the exhaust pipe with the other clamp.
NOTE: The clearances stated above are minimums.
Consideration must be given to the type accessory kit
XVHGZLWKGU\HU5HIHUWRWKHVSHFL¿FNLWLQVWUXFWLRQIRU
details.
Alcove Closet
Sides 0” 1”
Top 1” 1”
Front µ
Rear µ µ
WHEN INSTALLED IN MANUFACTURED (MOBILE) HOMES
Dryer must be exhausted to the outside. Exhaust MUST NOT be
terminated beneath mobile home. Exhaust material MUST NOT
support combustion. Installation MUST conform to Manufactured
+RPH&RQVWUXFWLRQ6DIHW\6WDQGDUG7LWOH&)53DUW
or when such standard is not applicable, the American National
6WDQGDUGRI0RELOH+RPHV$16,1)5$1R%)RUHOHFWULFDO
connection, see “Connecting dryer using 4 wire connection”.
USE OF CASTERS (120V PORTABLE MODELS ONLY)
For a portable installation screw casters into the holes on the bottom of the
dryer. Refer to the “Installation Instructions for caster assembly” sheet to
install casters.
)RUHYHU\H[WUDHOERZUHGXFHWKHDOORZDEOHYHQWV\VWHPOHQJWK
by 10 ft.
7ZRHOERZVZLOOEHWUHDWHGOLNHRQHHOERZ
)RUWKHVLGHH[KDXVWLQVWDOODWLRQVDGGRQHHOERZWRWKHFKDUW
The total vent system length includes all the straight portions and
HOERZVRIWKHV\VWHPWUDQVLWLRQGXFWLQFOXGHG
FLEXIBLE
7RWDO OHQJWK RI ÀH[LEOH PHWDO GXFW VKDOO QRW H[FHHG  IW  P 7KH
IROORZLQJNLWLVDYDLODEOHIURP\RXORFDOVHUYLFHRUJDQL]DWLRQ
.LW:;;µGLDÀH[LEOHPHWDOVHPLULJLG8/OLVWHGWUDQVLWLRQ
GXFWLQFOXGHVHOERZV
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

GE DSKS433EBWW Guide d'installation

Taper
Guide d'installation

dans d''autres langues