Generac iX1400 005842R0 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur
www.generac.com or 1-888-GENERAC
iX 1400
Digital Inverter Generator Operator's Manual
MODEL: 005842-0

DEADLY EXHAUST FUMES! ONLY use OUTSIDE
far away from windows, doors and vents.

NOT for use in critical life support applications.

SAVE this Manual. Provide this manual to any
operator of the generator.
Accessory Box ..............................................Inside Front Cover
Introduction ..............................................................................1
Read this Manual Thoroughly ..................................................1
Safety Rules ............................................................................1
Standards Index ...............................................................3
General Information .................................................................4
Specifications ...........................................................................4
Emissions Information ......................................................4
Unit Identification ......................................................................4
Control Panel....................................................................5
Operation .................................................................................5
Pre-Use Check ..........................................................................5
Starting the Generator ...............................................................6
Adding Loads ............................................................................6
Using the FlexPower
Switch ...................................................7
Using the 12 VDC Battery Charger ............................................7
Shutting Down ..........................................................................7
Low Oil Level Shutdown ............................................................8
Fueling the Generator ................................................................8
To Fill the Fuel Tank ..........................................................8
Adding Engine Oil ......................................................................8
To Add Engine Oil to the Crankcase ..................................8
Maintenance ............................................................................9
Generator Maintenance .............................................................9
Generator Maintenance Schedule ..............................................9
Cleaning the Generator ..............................................................9
Engine Maintenance ................................................................10
Changing the Engine Oil ..........................................................10
Changing the Fuel Filter ...........................................................10
Changing the Spark Plug .........................................................11
Transportation and Storage .....................................................11
Clean Spark Arrestor Screen ...................................................12
Troubleshooting .....................................................................13
Troubleshooting Guide .............................................................13
ACCESSORY BOX
Check all contents. If any parts are missing or damaged locate an
authorized dealer at 1-888-436-3722.
Contents include:
1 bottle SAE 30 Oil Oil Funnel
Spark Plug Wrench Screwdriver
Battery Charge Cable
Table of Contents
WARNING!
California Proposition 65
Engine exhaust and some of its constituents are known to the state of California to cause cancer,
birth defects, and other reproductive harm.
WARNING!
California Proposition 65
This product contains or emits chemicals known to the state of California to cause cancer,
birth defects, and other reproductive harm.
INTRODUCTION
Thank you for purchasing this model by Generac Power Systems,
Inc. This model is a compact, high performance, air-cooled,
engine driven generator designed to supply electrical power to
operate electrical loads where no utility power is available or in
place of utility due to a power outage.
READ THIS MANUAL THOROUGHLY
If any portion of this manual is not understood, contact the
nearest Authorized Dealer for starting, operating and servicing
procedures.
The operator is responsible for proper and safe use of the
equipment. We strongly recommend that the operator read this
manual and thoroughly understand all instructions before using the
equipment. We also strongly recommend instructing other users to
properly start and operate the unit. This prepares them if they need
to operate the equipment in an emergency.
The generator can operate safely, efficiently and reliably only if it
is properly located, operated and maintained. Before operating or
servicing the generator:
Become familiar with and strictly adhere to all local, state and
national codes and regulations.
Study all safety warnings in this manual and on the product
carefully.
Become familiar with this manual and the unit before use.
The manufacturer cannot anticipate every possible circumstance
that might involve a hazard. The warnings in this manual, and on
tags and decals affixed to the unit are, therefore, not all inclusive.
If using a procedure, work method or operating technique that the
manufacturer does not specifically recommend, ensure that it is
safe for others. Also make sure the procedure, work method or
operating technique utilized does not render the generator unsafe.
THE INFORMATION CONTAINED HEREIN WAS BASED ON
MACHINES IN PRODUCTION AT THE TIME OF PUBLICATION.
GENERAC RESERVES THE RIGHT TO MODIFY THIS MANUAL AT
ANY TIME.
SAFETY RULES
Throughout this publication, and on tags and decals affixed to the
generator, DANGER, WARNING, CAUTION and NOTE blocks are
used to alert personnel to special instructions about a particular
operation that may be hazardous if performed incorrectly or
carelessly. Observe them carefully. Their definitions are as
follows:
Indicates a hazardous situation or action which, if
not avoided, will result in death or serious injury.
Indicates a hazardous situation or action which,
if not avoided, could result in death or serious
injury.
Indicates a hazardous situation or action which,
if not avoided, could result in minor or moderate
injury.
NOTE:
Notes contain additional information important to a procedure
and will be found within the regular text body of this manual.
These safety warnings cannot eliminate the hazards that they
indicate. Common sense and strict compliance with the special
instructions while performing the action or service are essential to
preventing accidents.
Four commonly used safety symbols accompany the DANGER,
WARNING and CAUTION blocks. The type of information each
indicates is as follows:
This symbol points out important safety
information that, if not followed, could
endanger personal safety and/or property of
others.

This symbol points out potential explosion
hazard.
This symbol points out potential fire hazard.
This symbol points out potential electrical
shock hazard.
GENERAL HAZARDS
NEVER operate in an enclosed area, in a vehicle, or indoors
EVEN IF doors and windows are open.
• For safety reasons, the manufacturer recommends that the
maintenance of this equipment is carried out by an Authorized
Dealer. Inspect the generator regularly, and contact the nearest
Authorized Dealer for parts needing repair or replacement.
Operate generator only on level surfaces and where it will not be
exposed to excessive moisture, dirt, dust or corrosive vapors.
Keep hands, feet, clothing, etc., away from drive belts, fans,
and other moving parts. Never remove any fan guard or shield
while the unit is operating.
Certain parts of the generator get extremely hot during
operation. Keep clear of the generator until it has cooled to
avoid severe burns.
Do NOT operate generator in the rain.
Do not alter the construction of the generator or change controls
which might create an unsafe operating condition.
Never start or stop the unit with electrical loads connected
to receptacles AND with connected devices turned ON. Start
the engine and let it stabilize before connecting electrical
loads. Disconnect all electrical loads before shutting down the
generator.
1
Safety Rules
2
When working on this equipment, remain alert at all times.
Never work on the equipment when physically or mentally
fatigued.
Never use the generator or any of its parts as a step. Stepping
on the unit can stress and break parts, and may result in
dangerous operating conditions from leaking exhaust gases,
fuel leakage, oil leakage, etc.
EXHAUST & LOCATION HAZARDS
Never operate in an enclosed area or indoors! NEVER use
in the home, in a vehicle, or in partly enclosed areas such
as garages, even if doors and windows are open! ONLY use
outdoors and far from open windows, doors, vents, and in an
area that will not accumulate deadly exhaust.
The engine exhaust fumes contain carbon monoxide, which
you cannot see or smell. This poisonous gas, if breathed in
sufficient concentrations, can cause unconsciousness or even
death.
Adequate, unobstructed flow of cooling and ventilating air
is critical to correct generator operation. Do not alter the
installation or permit even partial blockage of ventilation
provisions, as this can seriously affect safe operation of the
generator. The generator MUST be operated outdoors.
This exhaust system must be properly maintained. Do nothing
that might render the exhaust system unsafe or in noncompliance
with any local codes and/or standards.
• Always use a battery operated carbon monoxide alarm indoors,
installed according to the manufacturers instructions.
If you start to feel sick, dizzy, or weak after the generator has
been running, move to fresh air IMMEDIATELY. See a doctor, as
you could have carbon monoxide poisoning.
ELECTRICAL HAZARDS
The generator produces dangerously high voltage when in
operation. Avoid contact with bare wires, terminals, connections,
etc., while the unit is running, even on equipment connected
to the generator. Ensure all appropriate covers, guards and
barriers are in place before operating the generator.
Never handle any kind of electrical cord or device while
standing in water, while barefoot or while hands or feet are wet.
DANGEROUS ELECTRICAL SHOCK MAY RESULT.
The National Electric Code (NEC) requires the frame and external
electrically conductive parts of the generator be properly
connected to an approved earth ground. Local electrical codes
may also require proper grounding of the generator. Consult
with a local electrician for grounding requirements in the area.
Use a ground fault circuit interrupter in any damp or highly
conductive area (such as metal decking or steel work).
Do not use worn, bare, frayed or otherwise damaged electrical
cord sets with the generator.
In case of accident caused by electric shock, immediately shut
down the source of electrical power. If this is not possible,
attempt to free the victim from the live conductor. AVOID
DIRECT CONTACT WITH THE VICTIM. Use a non-conducting
implement, such as a rope or board, to free the victim from the
live conductor. If the victim is unconscious, apply first aid and
get immediate medical help.
FIRE HAZARDS
Gasoline is highly FLAMMABLE and its vapors are EXPLOSIVE.
Do not permit smoking, open flames, sparks or heat in the
vicinity while handling gasoline.
Never add fuel while unit is running or hot. Allow engine to
cool completely before adding fuel.
Never fill fuel tank indoors. Comply with all laws regulating
storage and handling of gasoline.
Do not overfill the fuel tank. Always allow room for fuel
expansion. If tank is over-filled, fuel can overflow onto a hot
engine and cause FIRE or an EXPLOSION. Never store generator
with fuel in tank where gasoline vapors might reach an open
flame, spark or pilot light (as on a furnace, water heater or
clothes dryer). FIRE or EXPLOSION may result. Allow unit to
cool entirely before storage.
• Wipe up any fuel or oil spills immediately. Ensure that no
combustible materials are left on or near the generator. Keep the
area surrounding the generator clean and free from debris and
keep a clearance of five (5) feet on all side to allow for proper
ventilation of the generator.
Do not insert objects through unit’s cooling slots.
Save These Instructions – The manufacturer suggests that these rules for safe operation be copied
and posted near the unit's installation site. Safety should be stressed to all operators and potential
operators of this equipment. If you loan this unit to anyone, be sure to also loan this Owner's Manual
and advise that it be read thoroughly before operating the unit.
Safety Rules
• Do not operate the generator if connected electrical devices
overheat, if electrical output is lost, if engine or generator sparks
or if flames or smoke are observed while unit is running.
Keep a fire extinguisher near the generator at all times.
STANDARDS INDEX
1. National Fire Protection Association (NFPA) 70: The NATIONAL
ELECTRIC CODE (NEC) available from www.nfpa.org
2. National Fire Protection Association (NFPA) 5000: BUILDING
CONSTRUCTION AND SAFETY CODE available from www.
nfpa.org
3. International Building Code available from www.iccsafe.org
4. Agricultural Wiring Handbook available from www.rerc.org ,
Rural Electricity Resource Council P.O. Box 309 Wilmington,
OH 45177-0309
5. ASAE EP-364.2 Installation and Maintenance of Farm Standby
Electric Power available from www.asabe.org, American
Society of Agricultural & Biological Engineers 2950 Niles
Road, St. Joseph, MI 49085
This list is not all inclusive. Check with the Authority Having Local
Jurisdiction (AHJ) for any local codes or standards which may be
applicable to your jurisdiction.
MODEL NO:
SERIAL NO:
Figure 1 - Generator ID Plate
ID PLATE
3
Safety Rules
4
SPECIFICATIONS
Engine Type . . . . . . . . . . . . . . . . . . . . . . . . Single Cylinder, 4-Stroke
Engine Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80cc
Starter Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Recoil
Fuel Capacity/Type . . . . . . . . . . . . . . . . . 0.73 Gal (2.77 L)/Unleaded
Oil Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.63 Qt (0.6L)
Runtime Full/Half Load . . . . . . . . . . . . . . . . . . . . . . . . 2.5/5.0 Hours
Spark Plug Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BPR7HS
Spark Plug Gap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..030”
Dimensions L x W x H (in) . . . . . . . . . . . . . . . . . . . . . . 22 x 12 x 18
Weight Lb/kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46.0/20.09
Maximum AC Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1400W
Surge AC Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1450W
AC Volts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 VAC
Rated AC Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11.6 A
Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Hz
THD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.0%
Insulation Class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Class B
Outlets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(2) 5-15R, (1) 12 VDC
DC Volts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 VDC
Rated DC Current. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 A
NOTE:
Power output and runtime are influenced by many factors,
some of which are fuel quality, ambient temperature and engine
condition. Output decreases approximately 3.5% for each 1,000
feet above sea level and 1% for every 10 degrees above 60°F.
EMISSIONS INFORMATION
The Environmental Protection Agency (EPA) and California Air
Resource Board (CARB) require that your generator comply with
exhaust and evaporative emission standards. This generator is
certified to meet the applicable EPA and CARB emission levels.
Additional information regarding the requirements set by EPA and
CARB is as follows:
It is important that you follow the maintenance specifications
provided in this manual to ensure that your engine complies with
the applicable emission standards for the duration of the engine’s
life. This engine is certified to operate on gasoline. The emission
control system on your generator consists of the following:
Fuel System Air Induction System
~ Fuel Tank ~ Intake pipe/manifold
~ Fuel Cap ~ Air cleaner
~ Carburetor Ignition System
~ Fuel Lines ~ Spark plug
Evaporative Control System ~ Ignition module
~ Carbon Canister Exhaust System
~ Vapor Hoses ~ Pulse Air Injection Valve
~ Muffler
The Emissions Compliance Period referred to on the Emissions
Compliance Label indicates the number of operating hours for
which the engine has been shown to meet Federal and California
emission requirements. See the table below to determine the
compliance period for your generator. The displacement of your
generator is listed on the Emissions Compliance Label.
UNIT IDENTIFICATION (Figure 2)
1. Carrying Handle: Lift the generator by this handle only.
2. Spark Plug Cover: Allows access to the engine spark plug.
3. Fuel System Primer: Used to prime the fuel system for
starting.
4. Fuel Cap Pressure Valve: Allows air to enter the fuel tank to
equalize pressure.
5. Fuel Tank Cap: Access to fuel tank for filling.
6. Control Panel: location of generator controls and output
receptacles.
7. Air Intake Slats: Allows for cooling air to enter the housing.
8. Muffler: Lowers engine exhaust noise (includes the spark
arrestor).
9. Choke: Cold engine starting aid
10. Left Side Service Cover: Allows access to air filter, fuel filter
and oil fill.
11. Vent Hoses: Hoses allow venting of the carburetor.
12. Fuel Shutoff: Controls fuel supply to the carburetor.
13. Starter Rope: Pull rope for starting engine.
Figure 2 - Unit Identification
1
2
3
4
5
6
7
8
9
10
11
12
13
4
General Information
55
CONTROL PANEL (Figure 3)
14. LOW OIL LEVEL LED (yellow): Lights up when oil level is
below safe operating level and the engine shuts down..
15. OVERLOAD LED (red): Lights up if the generator experiences
a load greater than the rated output, low voltage, overheats or
the powered circuit experiences a short. The output is stopped
even though the engine keeps running.
16. READY LED (green): Indicates output from the generator
unless there is a low oil or overload condition.
17. 12 VDC Plug: Connection for re-charging 12VDC automotive-
style batteries while generator is in operation.
18. FlexPower™ Switch: This switch slows the engine speed
when the load is reduced to save fuel and engine wear.
19. 12 VDC Circuit Breaker: Overload protection for the 12 VDC
charging system.
20. Ground (Earth) Connection Lug: Grounding point for the
generator; consult state and local electrical codes before use
(floating ground).
21. 120 VAC Receptacles: Two (2) receptacles for connecting
accessories.
NOTE:
Do not exceed the rated output of the generator.
Figure 3 - Control Panel
14
15
16
17
18
19
20
21
PRE-USE CHECK
Prior to starting the generator and adding loads, perform the
following tasks:
1. Make sure the generator is on a firm, level (not to exceed 15°
in any direction), non-combustible surface with at least five
(5) feet of clearance on all sides.
Never operate in an enclosed area or
indoors! NEVER use in the home, in a
vehicle, or in partly enclosed areas such
as garages, even if doors and windows are
open! ONLY use outdoors and far from open
windows, doors, vents, and in an area that
will not accumulate deadly exhaust.
2. Remove the fuel cap and check the fuel level. If fuel is needed,
see the section “FUELING THE GENERATOR”.
3. Remove the left side service cover and check the oil level
by removing the oil filler cap. The oil level should be to the
bottom of the threads on the oil fill pipe. If oil is needed, see
the section “ADDING ENGINE OIL”.
4. Replace and secure the left side service cover.
5. Make sure there are no loads connected to the generator.
6. The National Electric Code (NEC) requires the frame and
external electrically conductive parts of the generator be
properly connected to an approved earth ground. Proper
grounding of the generator will prevent electrical shock in
the event of a ground fault condition in the generator or in
connected electrical devices. Proper grounding also helps
dissipate static electricity, which often builds up in unguarded
devices.
7. Local electrical codes may also require proper grounding of
the generator.
Starting the generator with accessories
connected to the 120 VAC outlets will
damage the generator and the connected
accessories.
Operation
6 6
STARTING THE GENERATOR
Once the fuel and oil levels have been checked and it has been
verified there are no loads connected, the generator may be
started. Turn the FlexPower Switch OFF (O).
1. Open the fuel valve (Figure 4), located below the starter rope
pull, by turning to the valve 90° counter-clockwise to the “ON”
(I) position.
2. Pull up on the center of the fuel fill cap and prime the fuel
system by depressing the plunger up to five (5) times with the
vent closed (Figure 5 on next page).
3. Open the fuel tank vent on the top of the fuel fill cap by turning
the center portion to the “ON” mark (Figure 6 on next page).
4. If the engine is cold or has not been run for some time, engage
the choke by pushing the choke lever to the right.
5. Grip the handle for the pull starter and brace your other hand
against the generator. Pull the rope slowly until resistance is
felt, then pull the rope rapidly.
Figure 4 - Fuel Valve
TURNING THE FUEL ON
6. If the engine does not start, repeat steps 2-5 until the engine
fires and begins to run.
7. Carefully adjust the choke to approximately the ½ position
until the engine begins to run smoothly, then push the lever all
the way to the left (Figure 6).
8. Make sure the bottom of the generator is not blocked by sand,
leaves, grass, etc. as the cooling vents are located on the
bottom of the unit.
Figure 5 - Prime Fuel System
FUEL
SYSTEM
VENT
PLUNGER
VENT
Figure 6 - Adjust Choke
ENGINE CHOKE
OPERATION
ON
I
OFF
O
ADDING LOADS
Once the generator has been running smoothly for 2-3 minutes,
electrical loads can be added.
 Do not use worn, bare, frayed or otherwise
damaged electrical cord sets with the
generator. Do not handle any kind of electrical
device while standing in water, while barefoot,
or while hands or feet are wet.
1. There are two grounded 120 VAC duplex outlets on the front
of the generator.
2. DO NOT overload the generator; if the red “overload” LED
lights up and the accessories attached to the generator
stop operating, stop the engine and reduce the load to the
generator. Restart and apply reduced loads.
3. Consult the following table to estimate what can be powered
by the generator.
Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Running Watts
*Air Conditioner (12,000 Btu) . . . . . . . . . . . . . . . . . . . . . . . . .1700
*Air Conditioner (24,000 Btu) . . . . . . . . . . . . . . . . . . . . . . . . .3800
*Air Conditioner (40,000 Btu) . . . . . . . . . . . . . . . . . . . . . . . . .6000
Battery Charger (20 Amp) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
Belt Sander (3") . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000
Chain Saw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
Circular Saw (6-1/2"). . . . . . . . . . . . . . . . . . . . . . . . . . 800 to 1000
*Clothes Dryer (Electric) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5750
*Clothes Dryer (Gas) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700
*Clothes Washer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1150
Coffee Maker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1750
*Compressor (1 HP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2000
*Compressor (3/4 HP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1800
*Compressor (1/2 HP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1400
Curling Iron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700
*Dehumidifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 650
Disc Sander (9") . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
Edge Trimmer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
Electric Blanket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400
Electric Nail Gun. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
Electric Range (per element) . . . . . . . . . . . . . . . . . . . . . . . . . . 1500
Electric Skillet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1250
*Freezer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700
*Furnace Fan (3/5 HP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 875
Operation
7
*Garage Door Opener. . . . . . . . . . . . . . . . . . . . . . . . . . . 500 to 750
Hair Dryer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
Hand Drill. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250 to 1100
Hedge Trimmer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 450
Impact Wrench . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
Iron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
*Jet Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800
Lawn Mower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
Light Bulb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Microwave Oven . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700 to 1000
*Milk Cooler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1100
Oil Burner on Furnace. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
Oil Fired Space Heater (140,000 Btu) . . . . . . . . . . . . . . . . . . . . . 400
Oil Fired Space Heater (85,000 Btu) . . . . . . . . . . . . . . . . . . . . . . 225
Oil Fired Space Heater (30,000 Btu) . . . . . . . . . . . . . . . . . . . . . . 150
*Paint Sprayer, Airless (1/3 HP) . . . . . . . . . . . . . . . . . . . . . . . . . 600
Paint Sprayer, Airless (handheld) . . . . . . . . . . . . . . . . . . . . . . . . 150
Radio. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 to 200
*Refrigerator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700
Slow Cooker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
*Submersible Pump (1-1/2 HP) . . . . . . . . . . . . . . . . . . . . . . . . 2800
*Submersible Pump (1 HP) . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000
*Submersible Pump (1/2 HP). . . . . . . . . . . . . . . . . . . . . . . . . . 1500
*Sump Pump. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800 to 1050
* Allow three (3) times the listed running watts for starting theses devices.
NOTE:
When an electric motor is started, the "OVERLOAD" LED may
light up for up to five (5) seconds (this is normal). If it stays on,
a fault has occured. Remove all loads and shut down generator
to reset the alarm. Restart the generator. If the "OVERLOAD"
LED remains lit, contact a Generac Dealer for assistance.
USING THE FLEXPOWER™ SWITCH
When the accessories connected to the generator are going to
be used intermittently (such as a hand drill), the FlexPower™
switch can be pushed to the “ON” (I) position. This will lower the
generator engine speed when loads are not being applied, saving
fuel, reducing engine wear and extending runtime.
USING THE 12 VDC BATTERY CHARGER
The 12 VDC receptacle may be used to recharge 12 VDC
automotive batteries only. The DC charging output is not regulated.
The circuit protector does not prevent over-charging a battery.
1. Connect the charging cable to the generator first, then the
battery, ALWAYS connecting the red lead to positive (+) and
the black to negative (-).
Do not permit smoking, open flame, sparks
or any other source of heat around a battery.
Wear protective goggles, rubber apron
and rubber gloves when working around
a battery. Battery electrolyte fluid is an
extremely corrosive sulfuric acid solution
that can cause severe burns. If a spill occurs,
flush area with clear water immediately.
Storage batteries give off explosive hydrogen
gas while recharging. An explosive mixture
will remain around the battery for a long
time after it has been charged. The slightest
spark can ignite the hydrogen and cause an
explosion. Such an explosion can shatter the
battery and cause blindness or other serious
injury.
NEVER reverse the polarity when connecting
the battery terminals to the charging jack.
Severe damage may occur to the generator
and battery.
2. Keep the FlexPower™ switch in the “OFF” (O) position.
3. Start the generator and use it as normal. Charging time will
vary with battery size and condition. Check the voltage at the
battery terminals once the charging cable has been unplugged
or the generator has been shut down.
NOTE:
This receptacle can not recharge 6-Volt batteries and can not
be used to crank an engine having a discharged battery.
SHUTTING DOWN
Once the generator is no longer needed it can be shut down.
1. Switch off any accessories connected to the generator. Unplug
any cords to the 120 VAC duplex outlets or the 12 VDC plug.
2. Turn the fuel valve to the “OFF” (O) position (Figure 7). A
switch behind the fuel valve grounds the ignition system,
stopping the engine and the fuel supply is shut off.
3. Close the vent on the fuel cap.
4. Allow the generator to cool before moving or storing.
Always allow the generator to cool off before
storing. High temperatures will be present
at the rear of the unit for some time after
shutdown.
Figure 7 - Turn Off Fuel
TURNING THE FUEL OFF
7
Operation
8
LOW OIL LEVEL SHUTDOWN
This generator is equipped with a low oil level shut down. If the oil
level in the engine crankcase drops below a pre-determined level,
the engine will stop automatically and the “LOW OIL LEVEL” LED
will light up.
Remove the Left Side Service Cover and check the oil level of
the engine. Add or drain oil as necessary; refer to see the section
ADDING ENGINE OIL”.
FUELING THE GENERATOR
Use care when fueling the generator. Only fill the fuel tank when
the generator has cooled entirely. Use fresh unleaded gasoline with
a minimum Research Octane Number (RON) of 87.
NOTE:
Do not use any gasoline containing more than 10% Ethanol.
NEVER fill the fuel tank with E85 or a mixture of oil and gasoline
designated for two-cycle engines.
Do not light a cigarette or smoke when filling the
fuel tank.
Gasoline is highly FLAMMABLE and its
vapors are EXPLOSIVE. Do not permit
smoking, open flames, sparks or heat in the
vicinity while handling gasoline.
Never fill fuel tank indoors. never fill fuel
thank when engine is running or hot. avoid
spilling gasoline on a hot engine. allow
engine to cool entirely before filling fuel tank.
Do not overfill the fuel tank. Always allow
room for fuel expansion. If tank is over-filled,
fuel can overflow onto a hot engine and
cause FIRE or an EXPLOSION. Wipe up fuel
spills immediately!
TO FILL THE FUEL TANK
1. Remove the fuel tank cap.
2. Add fuel slowly, stopping about two (2) inches below the top
of the filler neck.
3. Replace the fuel tank cap. Make sure the valve on the fuel cap
is in the “OFF” position.
4. If the generator is going to be started, refer to the section
“STARTING THE GENERATOR” for additional directions on
priming the fuel system.
Figure 8 - Fuel Tank Cap
FUEL
TANK
CAP
FILL TANK UNTIL
FUEL IS TWO (2)
INCHES BELOW
THE TOP
ADDING ENGINE OIL
All oil should meet minimum American Petroleum Institute (API)
Service Class SJ, SL or better. Do not use any aftermarket
additives.
Select the oil's viscosity grade according to the expected operating
temperature.
Above 40° F, use SAE 30
Below 40° F to 10° F, use 10W-30
Below 10° F, use synthetic 5W-30
10W-30
10W -3 0
SAE 30
SAE 3 0
Synthetic 5W-30
Syn t he tic 5 W -3 0
TO ADD ENGINE OIL TO THE CRANKCASE
1. Place the unit on a firm, level surface (not to exceed 15° in any
direction).
2. Remove the Left Side Service Cover.
3. Remove the oil fill cap located on the bottom of the engine
crankcase.
4. Add the recommended engine oil slowly, stopping frequently
to check the level. The full level is the base of the threads in
the filler neck. DO NOT OVERFILL!
8
Operation
9
5. Replace the oil fill cap and tighten.
6. Always check the oil level before starting the generator
engine.
DO NOT overfill the engine crankcase with
oil. High oil pressure may result, causing
premature engine wear and damage.
Figure 9 - Oil Fill
FULL OIL LEVEL
IS THE BOTTOM
OF THESE
THREADS
OIL FILL
CAP
GENERATOR MAINTENANCE
Proper care will ensure maximum performance of your generator.
Generator maintenance consists of keeping the unit clean and dry.
Operate and store the unit in a clean dry environment where it will
not be exposed to excessive dust, dirt, moisture or any corrosive
vapors.
Cooling air slots in the generator must not become clogged with
snow, leaves, or any other foreign material.
Check the cleanliness of the generator frequently and clean when
dust, dirt, oil, moisture or other foreign substances are visible on
its exterior surface.
NOTE:
Never insert any object or tool through the air cooling slots,
even if the engine is not running.
NOTE:
DO NOT use a garden hose to clean the generator. Water
can enter the engine fuel system and cause problems. In
addition, if water enters the generator through cooling air
slots, some water will be retained in voids and crevices of the
rotor and stator winding insulation. Water and dirt buildup on
the generator internal windings will eventually decrease the
insulation resistance of these windings.
GENERATOR MAINTENANCE SCHEDULE
Follow the recommended service schedule; to order replacement
parts call 1-888-436-3722.
Each
Use
Every 100
Hours
Every 6
Months
Each
Year
Fuel Level X
Oil Level X
Check Air Filter X
*Change Engine Oil X
**Clean Air Filter X
Check Spark Plug X
Check Muffler X
Inspect and Clean
Spark Arrestor
X
Replace Spark Plug X
Replace Fuel Filter X
* Perform initial oil change after the first five (5) hours of operation
** Clean the air filter more often if operating in dusty or sandy
conditions. Replace as necessary.
*** Inspect and clean every 50 hour of operation.
CLEANING THE GENERATOR
1. Use a damp cloth to wipe exterior surfaces clean.
2. A soft, bristle brush may be used to loosen caked on dirt, oil,
etc.
3. A vacuum cleaner may be used to pick up loose dirt and
debris.
4. Low pressure air (not to exceed 25 psi) may be used to
blow away dirt. Inspect cooling air slots and openings
on the generator. These openings must be kept clean and
unobstructed.
5. Inspect the vent hoses on the left side of the generator. Make
sure the hoses protrude through the slots below the door and
that the ends are open and free of debris.
9
Maintenance
10
ENGINE MAINTENANCE
NOTE:
Only work on a generator that has cooled completely.
Inspect the oil level and air filter condition each time you are going
to use the generator. To check the air filter and oil level the left side
service cover must be removed; use a screwdriver to loosen the
screw securing the cover and remove.
The air filter is located behind a cover for the air box (Figure 10).
Push the tab on the bottom of the air box upwards to release the
cover. To service the air cleaner:
1. Remove the air cleaner. Tap the element to shake loose any
large particles.
2. Wash the element in soapy water. Squeeze the filter dry in
clean cloth (DO NOT TWIST).
3. Soak the filter element in clean engine oil. Squeeze the excess
oil from the filter, leaving a light coating.
4. Clean air cleaner housing and cover before re-installing the
filter element.
Figure 10 - Air Filter
AIR
FILTER
FILTER
HOUSING
COVER
LEFT SIDE
SERVICE COVER
SCREW
LEFT SIDE
SERVICE
COVER
CHANGING THE ENGINE OIL
Hot oil may cause burns. Allow engine
to cool entirely before draining oil. Avoid
prolonged or repeated skin exposure with
used oil. Thoroughly wash exposed areas
with soap.
Change the engine oil after the first five (5) hours of operation.
Change the engine oil every 100 hours thereafter. To change the
engine oil:
Change the oil only when the fuel tank is low
or nearly empty. Tipping the generator with a
full fuel tank may cause fuel leakage.
1. Place the generator over a drain pan and remove the drain
plug. Tip the generator on its side to drain the used oil from
the crankcase.
NOTE:
To make draining the oil easier, a 6” length of vinyl (PVC) hose
with an inside diameter of 1.25” (32mm) any be placed over
the drain lip.
2. Tip the generator upright once the oil has finished draining.
Replace the engine oil with the proper grade called out in
Section “ADDING ENGINE OIL”, then replace the drain plug.
CHANGING THE FUEL FILTER
Locate the fuel filter, just below the engine intake housing (Figure
11). Make sure the Fuel Shutoff is in the “OFF” (O) position.
1. Remove the pinch clamps securing the fuel filter. Pull the
hoses free.
Wipe up any fuel spills immediately! Do not
smoke or replace the fuel filter near sparks
or open flame!
2. Replace the used filter with a new one. Push the fuel hoses
onto the barbed filter fittings until they are seated completely.
3. Replace the clamps, making sure they are seated on the
fittings.
Figure 11 - Fuel Filter
FUEL
FILTER
OIL FILL PLUG/
OIL DRAIN
CARBURETOR
VENT HOSE
CARBURETOR
DRAIN HOSE
10
Maintenance
11
CHANGING THE SPARK PLUG
Replace the spark plug each year, regardless of how many hours
the generator has been run. Use a NGK BPR7HS that has be
gapped to .030” (.76mm). To replace the spark plug:
1. Remove the spark plug cover on the top right side of the
generator, just below the handle (Figure 12).
2. Carefully pull the spark plug lead from the spark plug. Use a
socket wrench to remove the spark plug.
3. Install the new spark plug into the cylinder head. Tighten the
spark plug to 15 ft/lb.
4. Replace the spark plug lead, making sure it is fully seated.
5. Replace the spark plug cover.
Figure 12 - Replace Spark Plug
SPARK PLUG
LOCATION
TRANSPORTATION AND STORAGE
Transport or store the generator only if it has cooled completely.
Make sure the fuel valve and the vent on the fuel cap are both in
the OFF (“O”) position.
It is important to prevent gum deposits from forming in essential
fuel system parts such as the carburetor, fuel hose or tank during
long-term storage. Also, experience indicates that alcohol-blended
fuels (called gasohol, ethanol or methanol) can attract moisture,
which leads to separation and formation of acids; these acids gas
can damage the fuel system of an engine while in storage.
To avoid engine problems, the use of a commercial fuel stabilizer
prior to storage is recommended. Follow the manufacturer’s
instructions when adding the fuel stabilizer.
If the generator is going to be stored for more than six (6) months,
the generator should be prepared as follows:
1. Remove all gasoline from the fuel tank.
2. Start and run engine until engine stops from lack of fuel or
open the valve on carburetor bowl (Figure 13), and allow
gasoline to drain down tube into a receptacle. Discard
appropriately. Be sure to close the valve once the gasoline has
drained.
3. After the engine cools down, drain oil from crankcase. Refill
with recommended grade.
4. Remove spark plug and pour about 1/2 ounce (15 ml) of
engine oil into the cylinder. Cover spark plug hole with rag. Pull
the starting rope several times to coat the cylinder wall with
engine oil.
5. Install and tighten the spark plug.
6. Clean the generator outer surfaces. Check that cooling air
slots and openings on generator are open and unobstructed.
7. Store the unit in a clean, dry place.
Do not store gasoline from one season to another.
If possible, store the unit indoors and cover it to give protection
from dust and dirt.
Figure 13 - Carburetor Drain Valve
CARBUREATOR DRAIN
VALVE LOCATED BEHIND
AIR INTAKE
TURN VALVE COUNTER-
CLOCKWISE TO DRAIN FUEL,
CLOCKWISE TO CLOSE
Maintenance
12
CLEAN SPARK ARRESTOR SCREEN
The engine exhaust muffler has a spark arrestor screen. Inspect
and clean the screen every 50 hours of operation or once each
year, whichever comes first.
NOTE:
If using the generator on any forest covered, brush covered
unimproved land, it MUST BE equipped with a spark arrestor.
The spark arrestor must be maintained in cood condition by the
owner/operator.
Clean and ispect the spark arrestor as follows:
Remove the screen retainer by removing the retainer clamp.
Slide the spark arrestor screen out from the muvvler outlet
tube.
• Inspect screen and replace if torn, perforated or otherwise
damaged. Do NOT use a defective screen. If screen is not
damaged, clean with a commercial solvent.
Replace the screen and retainer and secure with retainer
clamp.
Figure 14 - Spark Arrestor Screen
Maintenance
13
TROUBLESHOOTING GUIDE
PROBLEM CAUSE CORRECTIVE ACTION
Engine won't start. 1. No fuel in tank.
2. Fuel valve turned off.
3. Defective spark plug.
4. Plugged fuel filter.
5. Defective or stuck engine stop switch.
1. Add fuel to tank.
2. Turn fuel valve on.
3. Replace spark plug.
4. Replace fuel filter.
5. Replace engine start switch.
Engine starts, then shuts down. 1. Low fuel level.
2. Fuel tank vent closed.
3. Incorrect engine oil level.
4. Contaminated fuel.
5. Defective low oil level switch.
6. Defective ignition coil.
1. Add fuel to tank.
2. Open fuel tank vent.
3. Check engine oil level, add or drain as needed.
4. Replace fuel filter.
5. Replace Low Oil Level switch.
6. Replace ignition coil.
Engine starts, then runs rough. 1. Choke is stuck or left on.
2. Dirty or clogged air filter.
3. Defective or dirty spark plug.
4. Dirty fuel filter.
5. Defective FlexPower switch.
1. Turn choke off.
2. Clean or replace the air filter element.
3. Replace spark plug.
4. Replace fuel filter.
5. Replace FlexPower switch.
No AC output. 1. Generator is overloaded (OVERLOAD LED is on).
2. AC voltage is low (OVERLOAD LED is on).
3. Inverter module is overheated (OVERLOAD LED is
on).
4. Short circuit in load (OVERLOAD LED is on).
5. Defective inverter assembly.
1. Shut down generator to reset module. Reduce
loads and restart generator.
2. Verify vent is open and choke is OFF.
3. Verify service door is ON. Let cool for 15 minutes
and restart generator.
4. Verify condition of any extension cords and all
loads being powere.
5. Replace inverter assembly.
No DC output. ** 1. DC circuit breaker is open.
2. Defective DC circuit breaker.
3. Defective rectifier.
1. Reset DC circuit breaker.
2. Replace DC circuit breaker.
3. Replace rectifier.
Fuel leaks from drain hoses. 1. Fuel system over primed (flooded).
2. Carburetor drain in bowl is not closed.
1. Turn vent in cap ON and let generator sit 15
minutes before restarting.
2. Turn valve clockwise to close.
* Engine speed increases and decreases — This is normal as the generator starts up and as loads vary.
** Verify FlexPower Switch is in the "O" OFF position.
Troubleshooting
Manual Part No. 0H8050 Rev F (06/26/13) Printed in China
www.generac.com o 1-888-GENERAC
iX 1400
Manual del Usuario del Generador Inversor
Digital
MODELO: 005842-0
PELIGRO
¡GASES DE ESCAPE MORTALES! ¡Utilícelo
SOLAMENTE al AIRE LIBRE y lejos de ventanas,
puertas y respiraderos!
NO diseñado para uso en aplicaciones de
soporte de vida crítica.

GUARDE este Manual. Proporcione este manual
a cualquier operador del generador.
Caja de accesorios ..........................Dentro de la portada
Introducción ....................................................................1
Lea este manual en su totalidad .....................................1
Reglas de Seguridad ......................................................1
Índice de normas .....................................................3
Información general........................................................4
Especificaciones ..............................................................4
Información de las emisiones ...................................4
Identificación de la unidad ................................................4
Panel de control .......................................................5
Operación .......................................................................5
Verificación antes de arrancar ..........................................5
Cómo arrancar el generador .............................................6
Cómo agregar cargas.......................................................6
Cómo usar el interruptor FlexPower™ ..............................7
Cómo usar el cargador de batería de 12 VCD ...................7
Cómo apagarlo ................................................................7
Paro por bajo nivel de aceite ............................................8
Cómo cargar combustible al generador ............................8
Para llenar el depósito de combustible .....................8
Cómo agregar aceite al motor ..........................................8
Para añadir aceite de motor al cárter del motor ........8
Mantenimiento ................................................................9
Mantenimiento del generador ...........................................9
Programa de mantenimiento del generador .......................9
Limpieza del generador ....................................................9
Mantenimiento del motor................................................10
Cambio del aceite de motor ...........................................10
Cambio del filtro de combustible ....................................10
Cambio de la bujía .........................................................11
Transporte y almacenamiento ........................................11
Limpieza del filtro del supresor de chispas .....................12
Localización y corrección de fallas ..............................13
Guía de detección de problemas ....................................13
CAJA DE ACCESORIOS
Compruebe todo el contenido. Si algunas piezas faltan o están dañadas,
localice a un distribuidor autorizado llamando al 1-888-436-3722.
El paquete incluye:
1 bote de aceite SAE 30 Embudo para aceite
• Llave para bujías Destornillador
Cable de carga de batería
Contenido
ADVERTENCIA!
Proposición 65 de California
El escape del motor y algunos de sus componentes son conocidos pore el Estado de California como
causa de cáncer, defectos congénitos y otros daños reproductivos.
ADVERTENCIA!
Proposición 65 de California
Este producto contiene o emite sustancias químicas que son conocidas por el Estado de California como
causa de cáncer, defectos congénitos y otros daños reproductivos.
INTRODUCCIÓN
Gracias por comprar este generador portátil de Generac Power Systems,
Inc. Este modelo es un generador compacto, de alto rendimiento,
enfriado por aire y accionado por un motor que está diseñado para
suministrar corriente eléctrica para impulsar cargas eléctricas donde no
esté disponible el servicio público eléctrico o en lugar del servicio público
eléctrico por un apagón.
LEA ESTE MANUAL EN SU TOTALIDAD
Si cualquier parte de este manual no se entiende, contacte al
Distribuidor Autorizado más cercano para obtener información sobre los
procedimientos de arranque, operación y mantenimiento.
El operador es responsable del uso apropiado y seguro del equipo.
Recomendamos encarecidamente que el operador lea este manual y
comprenda a fondo todas las instrucciones antes de usar el equipo.
También recomendamos encarecidamente darle instrucciones a otros
usuarios sobre cómo arrancar y operar correctamente la unidad. Esto los
preparará en caso de que necesiten operar el equipo en una emergencia.
El generador puede operar de forma segura, eficiente y confiable
solamente si se sitúa, opera y mantiene correctamente. Antes de operar o
dar mantenimiento al generador:
• Familiarícese con todos los códigos y regulaciones locales, estatales
y nacionales, y sígalas al pie de la letra.
• Estudie cuidadosamente todas las advertencias de seguridad en este
manual y en el producto.
Familiarícese con este manual y con la unidad antes de usarla.
El fabricante no puede anticipar cada circunstancia posible que pueda
implicar un riesgo. Las advertencias en este manual, y en las etiquetas
y calcomanías en la unidad son, por lo tanto, no exhaustivas. Si usa un
procedimiento, método de trabajo o técnica de operación que el fabricante
no recomiende específicamente, cerciórese de que es seguro para otros.
También asegúrese de que el procedimiento, método de trabajo o técnica
de operación utilizada no haga que el generador sea inseguro.
LA INFORMACIÓN INCLUIDA EN EL PRESENTE SE BASA EN LAS
MÁQUINAS EN PRODUCCIÓN A LA HORA DE LA PUBLICACIÓN.
GENERAC SE RESERVA EL DERECHO DE MODIFICAR ESTE MANUAL EN
CUALQUIER MOMENTO.
REGLAS DE SEGURIDAD
En esta publicación, y en las etiquetas y calcomanías en el generador,
los recuadros de PELIGRO, ADVERTENCIA, PRECAUCIÓN y NOTA se
utilizan para alertar al personal de instrucciones especiales sobre una
operación en particular que pueda ser peligrosa si se realiza incorrecta
o negligentemente. Obsérvelos cuidadosamente. Sus definiciones son
como sigue:
PELIGRO
Indica una situación o acción peligrosa que, si no se
evita, puede ocasionar la muerte o una lesión grave.
ADVERTENCIA
Indica una situación o acción peligrosa que, si no se
evita, podría ocasionar la muerte o una lesión grave.
CUIDADO
Indica una situación o acción peligrosa que, si no se
evita, podría ocasionar una lesión menor o moderada.
NOTA:
Las Notas contienen información adicional importante para un
procedimiento y se incluyen dentro del cuerpo del texto de este manual.
Estas advertencias de seguridad no pueden eliminar los peligros que
indican. El sentido común y el estricto cumplimiento con las instrucciones
especiales mientras realiza la acción o el servicio son esenciales para la
prevención de accidentes.
Cuatro símbolos de seguridad de uso frecuente acompañan los cuadros
de PELIGRO, ADVERTENCIA y PRECAUCIÓN. El tipo de información que
cada uno indica es como sigue:
Este símbolo señala información de seguridad
importante que, si no se sigue, podría poner en
peligro la seguridad personal y/o las propiedades
de terceros.

Este símbolo indica el riesgo de posible explosión.
Este símbolo indica el riesgo de posible incendio.
Este símbolo indica el riesgo de posible descarga
eléctrica.
PELIGROS GENERALES
NUNCA opere en un área cerrada o en interiores, en un vehículo,
incluso si las puertas y ventanas están abiertas.
Por razones de seguridad, el fabricante recomienda que el mantenimiento
de este equipo se realice por un Distribuidor Autorizado. Examine el
generador regularmente, y contacte al Distribuidor Autorizado más
cercano para las piezas que necesitan repararse o reemplazarse.
Sólo opere el generador en superficies niveladas y donde no esté
expuesto a humedad, suciedad, polvo o vapores corrosivos, en exceso.
Mantenga las manos, pies, ropa, etc, alejados de las bandas de
impulsión, de los ventiladores y de otras piezas móviles. Nunca quite
alguna guarda o blindaje de los ventiladores mientras la unidad está
en operación.
Ciertas piezas del generador se calientan demasiado durante la
operación. Manténgase alejado del generador hasta que se haya
enfriado para evitar quemaduras graves.
NO opere el generador en la lluvia.
No modifique la estructura del generador ni cambie los controles
puesto que podría crear una condición de funcionamiento insegura.
Nunca arranque o pare la unidad con las cargas eléctricas conectadas
a los tomacorrientes Y con los dispositivos conectados ENCENDIDOS.
Arranque el motor y déjelo estabilizarse antes de conectar las cargas
eléctricas. Desconecte todas las cargas eléctricas antes de apagar el
generador.
Al trabajar en este equipo, permanezca alerta todo el tiempo. Nunca
realice trabajos en el equipo cuando esté cansado físicamente o
mentalmente.
1
Reglas de seguridad
2
• Nunca utilice el generador o ninguna de sus piezas como escalón. Si
se para sobre la unidad puede ejercer presión y romper piezas, y esto
puede generar condiciones de funcionamiento peligrosas como fugas
de gases de escape, fugas de combustible, fugas de aceite, etc.
PELIGROS DEL ESCAPE Y DE LA UBICACIÓN
¡Nunca opere en áreas cerradas o interiores! ¡NUNCA opere en un
área cerrada, en un vehículo, o en el interior AUNQUE las puertas
y ventanas están abiertas! Úselo SÓLO en exteriores y lejos de
ventanas abiertas, puertas, ductos de ventilación y en áreas que
no acumularán el mortal gas del escape.
PELIGRO
El uso del generador en ambientes cerrados PUEDE
MATARLO EN MINUTOS.
El los gases de escape del generador contienen monóxido
de carbono. Este es un venenos que no se puede ver ni oler.
NUNCA lo utilice dentro de una
casa o garaje, INCLUSO SI las
puertas y las ventanas están
abiertas.
Utilícelo SOLAMENTE al aire
libre y lejos de ventanas,
puertas, respiraderos.
Los gases de escape del motor contiene monóxido de carbono,
que no se puede ver ni oler. Este gas venenoso, si es inhalado en
concentraciones altas, puede causar inconsciencia o incluso la
muerte.
El flujo adecuado y sin obstrucciones del aire de enfriamiento y de
ventilación es esencial para el correcto funcionamiento del generador.
No modifique la instalación ni permita algún bloqueo, incluso parcial,
de los componentes de la ventilación, ya que esto puede afectar
seriamente la operación segura del generador. El generador SE DEBE
poner en funcionamiento al aire libre.
Este sistema de escape debe recibir el mantenimiento correcto. No
haga nada que pueda hacer que el dispositivo de escape sea inseguro
o que no cumpla con los códigos o normas locales.
Utilice siempre una alarma a pilas para detección del monóxido de
carbono en interiores, siguiendo las instrucciones del fabricante.
Si comienza a sentirse enfermo, mareado o débil después de que
el generador esté en funcionamiento, trasládese a un lugar con aire
fresco INMEDIATAMENTE. Visite a un doctor, pues podría sufrir de
intoxicación por monóxido de carbono.
PELIGROS ELÉCTRICOS
El generador produce un voltaje peligrosamente alto cuando está en
funcionamiento. Evite tocar alambres pelados, los terminales, las
conexiones, etc. mientras la unidad está en funcionamiento, incluso
en el equipo conectado al generador. Asegúrese de que todas las
cubiertas, guardas y barreras adecuadas estén colocadas en su sitio
antes de hacer funcionar el generador.
• Nunca manipule ningún tipo de cable o dispositivo eléctrico mientras
esté parado en agua, mientras esté descalzo, o mientras tenga
las manos o los pies mojados. PUEDE SUFRIR UNA DESCARGA
ELÉCTRICA PELIGROSA.
El Código Eléctrico Nacional (NEC) requiere que el marco y las partes
conductoras del exterior del generador estén conectadas correctamente
a una tierra aprobada. Los códigos eléctricos locales pueden también
requerir que el generador se ponga a tierra adecuadamente. Consulte con
un electricista local sobre los requerimientos de puesta a tierra en su área.
Utilice un interruptor de circuito por falla a tierra en áreas húmedas
o altamente conductivas (como los trabajos en pisos metálicos o en
herrería).
No use cables eléctricos gastados, pelados, quemados o dañados de
alguna otra forma con el generador.
En caso de un accidente ocasionado por descarga eléctrica, corte
inmediatamente la fuente de corriente eléctrica. Si esto no es posible,
intente liberar a la víctima del conductor vivo. EVITE EL CONTACTO
DIRECTO CON LA VÍCTIMA. Utilice un instrumento no conductor, tal
como una cuerda o una tabla, para liberar a la víctima del conductor
vivo. Si la víctima está inconsciente, aplique los primeros auxilios y
consiga ayuda médica inmediatamente.
RIESGOS DE INCENDIOS
La gasolina es altamente INFLAMABLE y sus vapores son
EXPLOSIVOS. No permita fumar, llamas abiertas, chispas o calor a
su alrededor mientras manipula la gasolina.
Nunca añada combustible mientras la unidad está en funcionamiento
o caliente. Permita que el motor se enfríe totalmente antes de añadir
combustible.
Nunca llene el depósito de combustible en interiores. Cumpla con todas
las leyes que regulan el almacenamiento y el manejo de la gasolina.
No sobrellene el depósito de combustible. Siempre deje espacio
para la dilatación del combustible. Si se sobrellena el depósito, el
combustible puede desbordarse sobre el motor caliente y causar
un INCENDIO o una EXPLOSIÓN. Nunca almacene el generador con
combustible en el depósito donde los vapores de gasolina pueden
llegar a una llama abierta, una chispa o un piloto (como en un
horno, calentador de agua o un secadora de ropa). Puede suceder
un INCENDIO o una EXPLOSIÓN. Permita que la unidad se enfríe
totalmente antes de almacenarla.
• Limpie los derrames de combustible o aceite inmediatamente.
Asegúrese de que no se dejen materiales combustibles sobre o cerca
del generador. Mantenga el área alrededor del generador limpia y libre
de desechos y deje un espacio de cinco (5) pies a cada lado para
permitir la adecuada ventilación del generador.
No inserte objetos a través de las ranuras de enfriamiento de la unidad.
Guarde estas instrucciones – El fabricante sugiere que estas reglas para la operación segura se copien y
se coloquen cerca del sitio de instalación de la unidad. Se debe hacer hincapié de la seguridad a todos los
operadores y a los posibles operadores de este equipo. Si presta esta unidad a alguien, asegúrese también de
prestarle este Manual del Propietario a la persona y aconséjele que debe ser leído por completo antes de operar
la unidad.
Reglas de seguridad
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38

Generac iX1400 005842R0 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur