HeatStar HS170NG Le manuel du propriétaire

Catégorie
Chauffe-eau
Taper
Le manuel du propriétaire
70101
Heatstar by Enerco, 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 866-447-2194
FORCED-AIR NATURAL GAS-
CONSTRUCTION HEATER
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light appliance.
Extinguish any open flame.
Shut off gas to appliance.
Service must be performed by a qualified service agency.
This is an unvented gas-fired portable heater. It uses air (oxygen) from the area in which it is used.
Adequate combustion and ventilation air must be provided. Refer to page 3.
WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
HS170NG
OPERATING INSTRUCTIONS
AND OWNER’S MANUAL
READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe
place for future reference. Do not allow anyone who has not read these instructions to assemble,
light, adjust or operate the heater.
Model #
NEVER LEANEVER LEANEVER LEAVE THE HEAVE THE HEAVE THE HEATER UNATER UNATER UNATTENDED WHILE BURNING!TTENDED WHILE BURNING!TTENDED WHILE BURNING!
Force-Air Natural Gas Construction HeaterOperating Instructions and Owner’s Manual 2
SPECIFICATIONS
MODEL NO. ................................................. HS170NG
GAS TYPE ............................................. NATURAL GAS
BTU RATING. .......................................150,000 BTU/hr
(43.9 kW)
GAS SUPPLY PRESSURE TO REGULATOR:
Maximum: 1/2 psig (4.5kPa), Minimum: 9”WC (2.3 kPa)
REGULATOR OUT.............................. 4” WC (0.98 kPa)
ELECTRICAL INPUT ........................115V, 60 Hz, 1Ø, 3a
IGNITION....................... Direct Spark, interrupted type
PRIMARY FLAME CONTROL ... SolidState,10-15 sec. timing
HIGH TEMPERATURE CONTROL .......................240°F (116°C)
Minimum Ambient Temp. Rating: 0°F (-17.8°C)
FUEL CONSUMPTION ............................. 138 cu-m/hr
(3.9 cu-m/hr)
HEATED AIR OUTPUT: ......... 450 CFM (12.74 cu-m/min)
CONTENTS
Specifications .................................................................... 2
Operating Precautions ....................................................... 3
Safety Precations ............................................................... 3
Odor Fade Warning .......................................................... 4
Operating Instructions ......................................................5
Storage & Service ............................................................. 5
Wiring Diagram HS170NG ................................................. 6
Parts List HS170NG ........................................................... 7
Exploded View Drawing HS170NG ..................................... 7
WARNING:
FIRE, BURN, INHALATION, AND EXPLOSION HAZARD.
KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING
MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE
AWAY FROM THE HEATER AS RECOMMENDED BY THE
INSTRUCTIONS. NEVER USE THE HEATER IN SPACES
WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE
COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE,
SOLVENTS, PAINT THINNER, DUST PARTICLES OR
UNKNOWN CHEMICALS.
WARNING:
YOUR SAFETY IS IMPORTANT TO YOU AND TO OTH-
ERS, SO PLEASE READ THESE INSTRUCTIONS BEFORE
YOU OPERATE THIS HEATER.
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND
INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN
RESULT IN DEATH, SERIOUS BODILY INJURY AND
PROPERTY LOSS OR DAMAGE FROM HAZARDS OF
FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON
MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW
THE INSTRUCTIONS SHOULD USE OR SERVICE THIS
HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION
SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC.
CONTACT THE MANUFACTURER.
WARNING:
CARBON MONOXIDE CAN KILL
USING A POORTABLE HEATER IN AN ENCLOSED AREA
CAN PRODUCE DEADLY CARBON MONOXIDE.NOT FOR
HOME OR RECREATIONAL VEHICLE USE
Warranty and Service .................. .....................................8
FUEL ORIFICE PORT SIZE: .......................1.64±0.02mm
FUEL ORIFICE PORT N.°: ...........................................18
WARNING:THIS PRODUCT CAN EXPOSE
YOUTOCHEMICALSINCLUDINGLEADANDLEAD
COMPOUNDS, WHICH ARE KNOWN TO THE STATE
OFCALIFORNIATOCAUSECANCERANDBIRTH
DEFECTS OR OTHER REPRODUCTIVE HARM. FOR MORE
INFORMATION VISIT WWW.P65WARNINGS.CA.GOV
NEVER LEANEVER LEANEVER LEAVE THE HEAVE THE HEAVE THE HEATER UNATER UNATER UNATTENDED WHILE BURNING!TTENDED WHILE BURNING!TTENDED WHILE BURNING!
Force-Air Natural Gas Construction Heater Operating Instructions and Owner’s Manual
3
OPERATING PRECAUTIONS
This is a natural gas, direct-fired, forced air heater. It’s
intended use is primarily temporary heating of buildings
under construction, alteration or repair.
If natural gas leaks from a connection or fitting, it can mix
with the surrounding air, forming a potentially explosive
mixture. Obviously, natural gas leaks should be avoided,
so set up the natural gas supply with utmost care. Read
“Odor Fade” section for additional information about
detecting natural gas leaks. Leak check new connections or
reconnections with a soap and water solution and follow all
connection instructions herein. Also ask your natural gas
dealer for advice on the natural gas application and supply
installation and ask him to check it if there are any questions
This heater was designed and certified for use as a
construction heater in accordance with ANSI Standard Z83.7/
CGA 2.14. Check with your local fire safety authority if you
have any questions about your applications. Other standards
govern the use of fuel gases and heat producing products
in specific applications. Your local authority can advise you
about these.
Direct-Fired means that all of the combustion products enter
the heated space. Even though this heater operates very
close to 100 percent combustion efficiency, it still produces
small amounts of carbon monoxide. Carbon monoxide (called
CO) is toxic. We can tolerate small amounts but not a lot.
CO can build up in a heated space and failure to provide
adequate ventilation could result in death.
The symptoms of inadequate ventilation are:
• headache
• dizziness
• burning eyes and nose
• nausea
• dry mouth or sore throat
So, be sure to follow advice about ventilation in these
operating instructions.
Forced Air means that a blower or fan pushes the air through
the heater. Proper combustion depends upon this air flow;
therefore, the heater must not be revised, modified or
operated with parts removed or missing. Likewise, safety
systems must not be circumvented or modified in order to
operate the heater.
When the heater is to be operated in the presence
of other people the user is responsible for properly
acquainting those present with the safety precautions
and instructions, and of the hazards involved.
SAFETY PRECAUTIONS
1. Check the heater thoroughly for damage. DO NOT operate a
damaged heater.
2. DO NOT modify the heater or operate a heater which has been
modified from its original condition.
3. Use only natural gas.
4. Protect all natural gas connections from traffic or damage.
5. IMPORTANT Use only the regulator assembly provided with
the heater. Match the color stripe on the hang tag attached
to the hose assembly with the color on the label located near
the natural gas inlet fitting on the heater. Inspect the flexible
natural gas connections before each use of the heater. If there
is excessive abrasion or wear, or connection is damaged in any
way, replace with a connection meets all local, state, etc. codes
and requirements
6. For indoor use only. Area must be well ventilated. Figure 1.
(also see “Operating Precautions”).
7. If at any time gas odor is detected, IMMEDIATELY
DISCONTINUE operation until the source of gas has been
located and corrected. Read enclosed Odor fade and Natural
gas Sheet for additional information about detecting natural
gas leaks.
8. Install the heater such that it is not directly exposed to water
spray, rain and/or dripping water.
9. Maintain minimum clearance from normal combustible material
(like paper). Figure 2.
10. Due to the high surface and exhaust temperatures, adults and
children must observe clearances to avoid burns or clothing
ignition.
11. Operate only on a stable, level surface.
12. Do not use with duct work. Do not restrict inlet or exit.
13. Use only the electrical power specified. The electrical
connection and grounding must comply with National Electrical
Code - ANSI/NFPA 70 (USA) and CSA C22.1 Canadian Electrical
Code, Part 1 (Canada).
14. Use only a properly grounded 3-prong receptacle or extension
cord.
15. Do not move, handle or service while hot or burning.
16. Do not adjust the heater combustion tube elevation while
heater is running or hot. Adjustments to elevation should only
be made after the heater has cooled to touch.
17. Use only in accordance with local codes or, in the absence of
local codes, with the Standard for the Storage and Handling
of Liquefied Petroleum Gases ANSI/NFPA 58 and CSA B149.1,
Natural Gas and Natural gas Installation Code.
Opening Opening
Heater near floor near ceiling
Forced air (HS170NG) 3 ft2 3 ft2
Clearance Forced Air HS170NG
From floor .......................................................0 ft
From outlet ..................................................... 6 ft
From sides ......................................................2 ft
From top .........................................................3 ft
Locate 10 ft. from canvas or plastic tarpaulins or similar
coverings and secure them to prevent flapping or movement
due to wind action.
Figure 1
VENTILATION: Minimum openings required
Figure 2: MINIMUM CLEARANCE: From normal combustible materials
NEVER LEANEVER LEANEVER LEAVE THE HEAVE THE HEAVE THE HEATER UNATER UNATER UNATTENDED WHILE BURNING!TTENDED WHILE BURNING!TTENDED WHILE BURNING!
Force-Air Natural Gas Construction HeaterOperating Instructions and Owner’s Manual 4
FUEL GAS ODOR
LP gas and natural gas have man-made odorants added
specifically for detection of fuel gas leaks.
If a gas leak occurs you should be able to smell the
fuel gas. Since Propane gas (LP) is heavier than air you
should smell for the gas odor low to the floor. ANY
GAS ODOR IS YOUR SIGNAL TO GO INTO IMMEDIATE
ACTION!
Do not take any action that could ignite the fuel gas. Do
not operate any electrical switches. Do not pull any power
supply or extension cords. Do not light matches or any other
source of flame. Do not use your telephone.
Get everyone out of the building and away from the area
immediately.
Close all fuel supply valves, or the main fuel supply valve
located at the meter if you use natural gas.
Use your neighbor’s phone and call your fuel gas supplier and
your fire department. Do not re-enter the building or area.
Stay out of the building and away from the area until
declared safe by the firefighters and your fuel gas supplier.
FINALLY, let the fuel gas service person and the firefighters
check for escaped gas. Have them air out the building and
area before you return. Properly trained service people must
repair any leaks, check for further leakages, and then relight
the appliance for you.
ODOR FADING - NO ODOR DETECTED
Some people cannot smell well. Some people cannot smell
the odor of the man-made chemical added to natural gas
(LP) or natural gas. You must determine if you can smell the
odorant in these fuel gases.
Learn to recognize the odor of propane (LP) gas and natural
gas. Local propane (LP) gas dealers will be more than happy
to give you a scratch and sniff pamphlet. Use it to become
familiar with the fuel gas odor.
Smoking can decrease your ability to smell. Being around
an odor for a period of time can affect your sensitivity to
that particular odor. Odors present in animal confinement
buildings can mask fuel gas odor.
The odorant in propane (LP) gas and natural gas is
colorless and the intensity of its odor can fade under
some circumstances.
If there is an underground leak, the movement of gas
through the soil can filter the odorant.
ODOR FADE WARNING
WARNING
Asphyxiation Hazard
Do not use this heater for heating human living quarters.
Do not use in unventilated areas.
The flow of combustion and ventilation air must not be obstructed.
Proper ventilation air must be provided to support the combustion air requirements of the heater being used.
Refer to the specification section of the heater’s manual, heater data plate, or contact the Factory to determine combustion air
ventilation requirements of the heater.
Lack of proper ventilation air will lead to improper combustion.
Improper combustion can lead to carbon monoxide poisoning leading to serious injury or death. Symptom of carbon monoxide
poisoning can include headaches dizziness and difficulty in breathing.
Propane (LP) gas odor may differ in intensity at different
levels. Since Propane (LP) gas is heavier than air, there may
be more odor at lower levels.
Always be sensitive to the slightest gas odor. If you
continue to detect any gas odor, no matter how small, treat
it as a serious leak. Immediately go into action as discussed
previously.
ATTENTION - CRITICAL POINTS TO
REMEMBER!
Propane (LP) and natural gas have a distinctive odor.
Learn to recognize these odors. (Reference Fuel Gas
Odor and Odor Fading sections above.
Even If you are not properly trained in the service and repair
of the heater, ALWAYS be consciously aware of the odors of
propane gas (LP) gas and natural gas.
If you have not been properly trained in repair and service of
propane gas (LP) or natural gas then do not attempt to light
heater, perform service or repairs, or make any adjustments
to the heater on the propane gas (LP) or natural gas fuel
system.
A periodic sniff test around the heater or at the heater’s
joints; i.e. hose, connections, etc., is a good safety practice
under any conditions. If you smell even a small amount of
gas, CONTACT YOUR FUEL GAS SUPPLIER IMMEDIATELY.
DO NOT WAIT!
Heater Elevation Adjustment
This heater is equiped with an elevation adjustment panel located
at the exhaust end of the control box.
1. Do not adjust the heater combustion tube elevation while
heater is running or hot. Adjustments to elevation should only
be made after the heater has cooled to touch.
2. To adjust the heater combustion tube elevation, turn the
adjustment screw knob counterclockwise and lift the
combustion tube to desired position.
NEVER LEANEVER LEANEVER LEAVE THE HEAVE THE HEAVE THE HEATER UNATER UNATER UNATTENDED WHILE BURNING!TTENDED WHILE BURNING!TTENDED WHILE BURNING!
Force-Air Natural Gas Construction Heater Operating Instructions and Owner’s Manual
5
OPERATING INSTRUCTIONS
PREPARING FOR OPERATION
1. Check the heater for possible shipping damage. If any is
found, immediately notify the factory.
2. Follow all of the “Precautions”.
3. Assemble the regulator to the heater fuel inlet with the gas
flow arrow pointed toward the heater. You should use a
pipe sealant onto the male pipe thread, since this will insure
that no sealant gets into the fuel system. Then screw the
male thread into the inlet and tighten by rotating clockwise.
4. Connect the hose to the heater by rotating the hose fitting
clockwise.
5. Securely tighten all gas connections.
6. Open the natural gas valve and check all gas connections
with a soap and water solution. DO NOT USE A FLAME.
7. Connect power cord to well-grounded 115V, 60 Hz, 1Ø
source of power.
8. When using an extension cord, make certain that it is a
3-wire (grounded) cord of proper wire size.
START
1. Slowly open the main natural gas valve.
2. Set thermostat to full on. Heater will ignite automatically.
3. Set thermostat to desired temperature. Heater will turn off
and on automatically as the temperature varies in the heater
area.
STOP
1. Securely close valve on the natural gas supply.
2. Continue to operate heater until all fuel in the hose has
burned.
3. Unplug the heater from electrical supply.
RESTART AFTER SAFETY SHUTDOWN
1. Securely close valve at natural gas cylinder. Unplug heater.
2. Wait 5 minutes.
3. Restart following “Start” procedure.
MAINTENANCE AND STORAGE
1. The heater should be inspected before each use, and at least
annually by a qualified person.
2. Turn off the natural gas supply valve when the heater is not
in use.
SERVICING
A hazardous condition may result if a heater is used that has
been modified or is not functioning properly.
When the heater is working properly:
The flame is contained within the heater.
The flame is essentially blue with perhaps some
yellow tipping.
There is no strong disagreeable odor, eye burning or
other physical discomfort.
There is no smoke or soot internal or external to the
heater.
There are no unplanned or unexplained shut downs
of the heater.
The parts lists and wiring diagram show the heater as it was
constructed. Do not use a heater which is different from that
shown. In this regard, use only the regulator supplied with
the heater. IMPORTANT Match the color stripe on the hang
tag attached to the hose assembly with the color on the label
located near the natural gas inlet fitting on the heater. Do
not use alternates. For this heater, the regulator must be set
as shown in “specifications”. If there is any uncertainty about
the regulator setting, have it checked.
A heater which is not working right must be repaired, but
only by a trained, experienced service person.
In-warranty products will be repaired with no charge for
either parts or labor. Please include a brief statement
indicating date, place of purchase, the nature of the problem
and proof of purchase.
Out-of-warrranty products will be repaired with a charge for
parts and labor.
CAUTION:
Failure to unplug the unit may result in unexpected
operation.
NEVER LEANEVER LEANEVER LEAVE THE HEAVE THE HEAVE THE HEATER UNATER UNATER UNATTENDED WHILE BURNING!TTENDED WHILE BURNING!TTENDED WHILE BURNING!
Force-Air Natural Gas Construction HeaterOperating Instructions and Owner’s Manual 6
If any original wiring as supplied by the heater must be replaced,
it must be replaced with type AWG 105° C wire or its equivalent
except as indicated (*type SF2-200, **SGI 250° C).
HS170NG - WIRING CHART
COLOR LENGTH FROM TO
White 7” Valve Terminal Block
Black 6” On/Off Switch Terminal Block
Red-(Hi-Temp) 16 1/2” High Limit Switch Valve
Red-(Hi-Temp) 16 1/2” High Limit Switch Terminal Block
Orange 11” Flame Control Spark Plug
(Ignition)
Green 7” Flame Control Ground
(Harness)
Red 7” Flame Control Terminal Block
(Harness)
White 6” Flame Control Terminal Block
(Harness)
Black 6” Flame Control Terminal Block
(Harness)
HOW MUCH HEAT DO I REQUIRE?
For economy, it is important to match input to that required. But
heat requirements often vary. For example, it usually takes a lot
more heat to get things warm than it does to keep them that
way. Likewise, outside air temperature usually changes during
the day so you may need more heat at night than you do in the
daytime. An approximation of the heat required can be found by
using the chart below.
Cubic feet Temperature Rise Required (oF)*
of space to
be heated 20o30o40o50o
5,000 14,000 20,000 27,999 34,000
7,000 19,000 28,000 38,000 47,000
10,000 27,000 40,000 54,000 67,000
15,000 40,000 60,000 80,000
100,000
20,000 54,000 80,000 107,000 133,000
30.000 80,000 120,000 160,000 200,000
50,000 133,000 200,000 266,000 333,000
BTU’S PER HOUR REQUIRED
Recommended Minimum Gauge
for Cord Extensions
Wire Gauge Chart A.W.G.
Name
Plate 120V Cord Length in Feet
Amps. 25 50 100 150
5-6 18 16 14 12
6-8 18 16 12 10
8-12 18 14 12 10
10-12 16 14 10 8
12-14 16 12 10 8
WARNING: When using a thermostat controlled heater,
its exit area should be protected from personnel and
warnings posted of sudden startup.
Model #HS170NG
WIRING DIAGRAM
NEVER LEANEVER LEANEVER LEAVE THE HEAVE THE HEAVE THE HEATER UNATER UNATER UNATTENDED WHILE BURNING!TTENDED WHILE BURNING!TTENDED WHILE BURNING!
Force-Air Natural Gas Construction Heater Operating Instructions and Owner’s Manual
7
Item Part No. Description Qty.
Item Part No. Description Qty.
1 21735 Outer Shell - Model MH, HS 1
2 22249 Middle Cylinder 1
3 22261 Orifice Assembly 1
4 21146 Flame Holder Assembly 1
5 26168 High Limit Switch 1
6 23038 Orifice Nut 1
7 Handle 1
8 Handle Mounting Clips 2
9 26010 Set Screw, Nyloc 1
10 26074 Fan 1
11 22251 Motor Assembly 1
12 22252 Grille, Inlet/Motor Mounting 1
13 22262 Regulator, 4” WC 1
14 22263 Male Fitting Conn. 1
3/8MPT x 3/8SAE FLR
15 22264 Solenoid Valve, Goyen 1
16 22265 Fitting Close Nipple 1
17 22266 Fuel Tube Assembly 1
18 21084 Electrode, Spark 1
19 24340 Thermostat Mounting Bracket 1
20 22254 Thermostat Assembly 1
21 26070 Loop Clamp, 5/16 1
22 27808 Flame Control, Potted 1
23 21036 Power Cord Assembly 1
24 28771 Terminal Board 1
25 26223 Bushing Strain Relief 1
26 28772 Knob, Thermostat 1
27 22255 Control Box 1
28 22273 Base, Control Box 1
MODEL# HS170NG PARTS LIST
27094
27095
NEVER LEANEVER LEANEVER LEAVE THE HEAVE THE HEAVE THE HEATER UNATER UNATER UNATTENDED WHILE BURNING!TTENDED WHILE BURNING!TTENDED WHILE BURNING!
WARNING
Air Quality Hazard
Do not use this heater for heating human living quarters.
Use of direct-fired heaters in the construction environment can result in exposure to levels of CO, CO2, and NO2 considered
to be hazardous to health and potentially life threatening.
Do not use in unventilated areas.
Know the signs of CO and CO2 poisoning.
ǞHeadaches, stinging eyes
ǞDizziness, disorientation
ǞDifficulty breathing, feels of being suffocated
Proper ventilation air exchange (OSHA 29 CFR 1926.57) to support combustion and maintain acceptable air quality shall be
provided in accordance with OSHA 29 CFR Part 1926.154, ANSI A10.10 Safety Requirements for Temporary and Portable
Space Heating Devices and Equipment used in the Construction Industry or the Natural Gas and Propane Installation Codes
CSA B149.1.
ǞPeriodicallymonitorlevelsofCO,CO2andNO2existingattheconstructionsite–attheminimumatthestartofthe
shift and after 4 hours.
ǞProvide ventilation air exchange, either natural or mechanical, as required to maintain acceptable indoor air quality.
USA 8-Hr Time weighted average
(OSHA 29 CFR 1926.55 App A)
Canada 8-hr time weighted average
WorkSafe BC OHS Guidelines Part 5.1
and Ontario Workplaces Reg 833
CO 50 ppm
CO25000 ppm
NO2
USA– CeilingLimit
(ShortTermExposureLimit=15minutes)
CanadaSTEL(15minutesReg833/1hour
WSBC) WorkSafe BC OHS Guidelines Part
5.1 and Ontario Workplaces Reg 833
CO 100 ppm
CO215000 ppm (WSBC)
3000 ppm (Reg 833)
NO25ppm 1.0 ppm (WorkSafeBC)
5.0 ppm (Reg 833)
Ensure that the flow of combustion and ventilation air exchange cannot become obstructed.
• Asthebuilding‘tightensup’duringtheconstructionphasesventilationmayneedtobeincreased.
NEVER LEANEVER LEANEVER LEAVE THE HEAVE THE HEAVE THE HEATER UNATER UNATER UNATTENDED WHILE BURNING!TTENDED WHILE BURNING!TTENDED WHILE BURNING!
HS170NG
OPERATING INSTRUCTIONS
AND OWNER’S MANUAL
READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe
place for future reference. Do not allow anyone who has not read these instructions to assemble,
light, adjust or operate the heater.
Model #
WARNING:
USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS
COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE
DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE
AGENCY.
PARTS ORDERING INFORMATION:
PURCHASING: Accessories may be purchased at any HeatStar local dealer or direct
from the factory.
FOR INFORMATION REGARDING SERVICE
Please call Toll-Free 866-447-2194 • www.HeatStar.com
Our office hours are 8:00 AM – 5:00 PM, EST, Monday through Friday.
Email to: techservice@enerco-HeatStar.com
Please include the model number, date of purchase, and description of problem in all
communication.
LIMITED WARRANTY
The company warrants this product to be free from imperfections in material or workmanship,
under normal and proper use in accordance with instructions of The Company, for a period
of one year from the date of delivery to the buyer. The Company, at its option, will repair or
replace products returned by the buyer to the factory, transportation prepaid within said one
year period and found by the Company to have imperfections in material or workmanship.
If a part is damaged or missing, call our Technical Support Department at 866-447-2194.
Address any Warranty Claims to the Service Department, HeatStar, Inc., 4560 W. 160th St.,
Cleveland, Ohio 44135. Include your name, address and telephone number and include details
concerning the claim. Also, supply us with the purchase date and the name and address of the
dealer from whom you purchased our product.
The foregoing is the full extent of the responsibility of the Company. There are no other
warranties, express or implied. Specifically there is no warranty of fitness for a particular
purpose and there is no warranty of merchantability. In no event shall the Company be liable for
delay caused by imperfections, for consequential damages, or for any charges of the expense
of any nature incurred without its written consent. The cost of repair or replacement shall be
the exclusive remedy for any breach of warranty. There is no warranty against infringement of
the like and no implied warranty arising from course of dealing or usage of trade. This warranty
will not apply to any product which has been repaired or altered outside of the factory in any
respect which in our judgment affects its condition or operation.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so
the above limitation or exclusion may not apply to you. This Warranty gives you specific legal
rights, and you may have other rights which vary from state to state.
HeatStar, Inc., reserves the right to make changes at any time, without notice or
obligation, in colors, specifications, accessories, materials and models.
HeatStar, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 800-251-0001
HeatStar is a registered trademarks of Enerco Group, Inc.
© 2019, Enerco Group, Inc. All rights reserved
PRODUCT REGISTRATION: Thank you for your purchase.
Please log in to http://www.egiregistration.com to register your product.
NEVER LEANEVER LEANEVER LEAVE THE HEAVE THE HEAVE THE HEATER UNATER UNATER UNATTENDED WHILE BURNING!TTENDED WHILE BURNING!TTENDED WHILE BURNING!
AVERTISSEMENT : Le non-respect des instructions, telles qu’indiquées dans le présent
guide, risque de causer une explosion ou un incendie entraînant des dommages matériels
ou des blessures graves, voire mortelles.
70101
Heatstar by Enerco, 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 800-251-0001
APPAREIL DE CHAUFFAGE AU GAZ NATUREL À
AIRPULSÉ POUR CHANTIER DE CONSTRUCTION
N’entreposez ni n’utilisez d’essence ou autres liquides ou vapeurs inflammables à proximité de
ce type d’appareil.
EN PRÉSENCE D’UNE ODEUR DE GAZ
Ne tentez pas d’allumer l’appareil de chauffage.
Éteignez toute flamme nue.
Fermez l’alimentation en gaz à l’appareil.
L’entretien doit être effectué par un fournisseur de services d’entretien qualifié.
Cet appareil de chauffage portatif alimenté au gaz n’est pas ventilé. Il utilise l’oxygène de l’air ambiant.
Une circulation d’air adéquate doit être assurée pour la combustion et la ventilation. Voir page 3.
Modèle # HS170NG
HS170NG
GUIDE D’UTILISATION ET
MANUEL DU PROPRIÉTAIRE
LISEZ SOIGNEUSEMENT LES INSTRUCTIONS : Lisez et observez toutes les instructions. Conservez ces
instructions dans un endroit sécuritaire pour vous y référer ultérieurement. Ne permettez pas à quiconque
n’ayant pas lu les présentes instructions d’assembler, d’allumer, de régler ou de faire fonctionner l’appareil.
Modèle #
NE JAMAIS LAISSER LE CHAUFFNE JAMAIS LAISSER LE CHAUFFNE JAMAIS LAISSER LE CHAUFFAGE SANS SURAGE SANS SURAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!VEILLANCE PENDANT LE BRÛLAGE!VEILLANCE PENDANT LE BRÛLAGE!
Force-Air Natural Gas Construction HeaterOperating Instructions and Owner’s Manual 2
SPÉCIFICATIONS
MODÈLE N°.................................................................HS170NG
TYPE DE GAZ...........................................................Gaz Naturel-
COTE BTUDe.....................................43.9 kW (150,000 BTU/hr)
TABLE DES MATIÈRES
Spécifications .............................................................................. 2
Précautions liées au fonctionnement .......................................... 3
Précautions liées à la sécurité ..................................................... 3
Avertissement relatif aux substances odorantes .......................... 4
Instructions de fonctionnement ................................................. 5
Entreposage et entretien ............................................................ 5
Schéma de câblage (Modèle n° HS170NG) .................................. 6
Liste des pièces (Modèle n° HS170NG) ........................................ 7
Plan détaillé (Modèle n° HS170NG) ............................................. 7
AVERTISSEMENT :
DANGER D’INCENDIE, D’INHALATION ET D’EXPLOSION.
GARDEZ LES COMBUSTIBLES SOLIDES TELS QUE LES
MATÉRIAUX DE CONSTRUCTION LE PAPIER ET LE CARTON À
UNE DISTANCE SÉCURITAIRE DE L’APPAREIL DE CHAUFFAGE
TEL QUE RECOMMANDÉ DANS LES INSTRUCTIONS.
N’UTILISEZ JAMAIS L’APPAREIL DE CHAUFFAGE DANS UN
ENDROIT QUI CONTIENT OU RISQUE DE CONTENIR DES
COMBUSTIBLES VOLATILES OU EN SUSPENSION DANS L’AIR,
OU DES PRODUITS TELS QUE DE L’ESSENCE, DES SOLVANTS,
DU DILUANT À PEINTURE, DES PARTICULES DE POUSSIÈRE
OU DES PRODUITS CHIMIQUES INCONNUS.
AVERTISSEMENT :
NON CONÇU POUR UNE UTILISATION À L’INTÉRIEUR DE LA
MAISON OU DANS UN VÉHICULE RÉCRÉATIF.
AVERTISSEMENT :
VOTRE SÉCURITÉ EST IMPORTANTE POUR VOUS ET POUR LES
AUTRES, PAR CONSÉQUENT VEUILLEZ LIRE CES DIRECTIVES
AVANT DE FAIRE FONCTIONNER CET APPAREIL DE CHAUFFAGE.
AVERTISSEMENT GÉNÉRAL
DE DANGER :
LE NON-RESPECT DES MESURES DE PRÉVENTION ET DES
INSTRUCTIONS FOURNIES AVEC CET APPAREIL DE CHAUFFAGE
RISQUE DE CAUSER LA MORT, DES BLESSURES GRAVES ET
DES DOMMAGES OU DES PERTES MATÉRIELLES RÉSULTANT
D’INCENDIE, D’EXPLOSION, DE BRÛLURE, D’ASPHYXIE,
D’INTOXICATION AU MONOXYDE DE CARBONE ET/OU
D’ÉLECTROCUTION. SEULES LES PERSONNES APTES
À COMPRENDRE ET À RESPECTER LES INSTRUCTIONS
DEVRAIENT UTILISER OU EFFECTUER LE SERVICE DE CET
APPAREIL DE CHAUFFAGE.
SI VOUS AVEZ BESOIN D’AIDE OU D’INFORMATION
CONCERNANT L’APPAREIL DE CHAUFFAGE TELS QUE
MANUEL D’INSTRUCTIONS, ÉTIQUETTES, ETC., VEUILLEZ
COMMUNIQUER AVEC LE FABRICANT.
PRESSION D’ALIMENTATION EN GAZ À L’ENTRÉE DU
RÉGULATEUR
MAXIMUM: 1/2PSIG (3,4 KPA), MINIMUM:9”C.E.(2,3 KPA)
SORTIE DU RÉGULATEUR ............... 4” C.E. (0,98 kPa)
ENTRÉE ÉLECTRIQUE 115V, 60 Hz, 1Ø, 3a
ALLUMAGE .................. Étincelle directe, à interruption
TAILLE DU PORT D'ORIFICE DE CARBURANT:............1.64
±0.02mm
SORTIE D’AIR CHAUD : 450 PI3/MIN (12,74 M3/MIN)
CONTRÔLE DE FLAMME PRINCIPAL Transistorisé,
temporisation 10-15 s
LIMITE SUPÉRIEURE DE TEMPÉRATURE 240°F (116°C)
Valeur nominale de température ambiante minimale: 0°F
(-17,8°C)
CONSOMMATION ÉNERGÉTIQUE ...138 pi3/h (3,9 m3/h)
NOMBRE D'ORIFICES DE PORT DE CARBURANT:..........18
Garantie et service ..................................................................... 8
AVERTISSEMENT: CE PRODUIT PEUT
VOUSEXPOSERÀPLOMBETCOMPOSÉSDEPLOMB,
IDENTIFIÉPARL'ÉTATDECALIFORNIECOMMEPOUVANT
CAUSERLECANCER.LAVEZ-VOUSLESMAINSAPRÈS
AVOIRMANIPULÉCEPRODUIT.POURDEPLUSAMPLES
INFORMATIONS,PRIÈREDECONSULTERWWW.
P65WARNINGS.CA.GOV.
NE JAMAIS LAISSER LE CHAUFFNE JAMAIS LAISSER LE CHAUFFNE JAMAIS LAISSER LE CHAUFFAGE SANS SURAGE SANS SURAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!VEILLANCE PENDANT LE BRÛLAGE!VEILLANCE PENDANT LE BRÛLAGE!
Force-Air Natural Gas Construction Heater Operating Instructions and Owner’s Manual
3
PRÉCAUTIONS LIÉES AU FONCTIONNEMENT
Cet appareil de chauffage à air pulsé et à feu direct fonctionne
au gaz naturel. Il est destiné principalement à chauffer
temporairement des édifices en construction, en rénovation ou en
réparation.
Le gaz naturel est plus lourd que l’air. Si du gaz naturel fuit d’une
connexion ou d’un raccord, il se dirige vers le plancher, se mélange
avec l’air ambiant et forme un mélange potentiellement explosif.
Évidemment, les fuites de gaz naturel devraient être évitées ; il est
donc important de raccorder l’alimentation en natural gas avec
le plus grand soin. Veuillez lire le feuillet « Substance odorante
et gaz naturel » ci-joint pour obtenir plus de précisions relatives
à la détection des fuites de gaz naturel. Vérifiez la présence de
fuite aux nouvelles connexions et raccords en utilisant un mélange
d’eau et de savon et suivez les instructions mentionnées. Obtenez
également les conseils de votre détaillant quant à votre installation
au natural gas et posez-lui toute question que vous auriez à cet
égard.
Cet appareil a été conçu et homologué pour être utilisé
comme appareil de chauffage pour chantier de construction,
conformément à la norme ANSI Z83.7/CGA 2.14. Soumettez
à l’organisme local responsable de la sécurité et des incendies
toute question relative à votre type d’installation. Selon le type
d’application, d’autres normes peuvent s’appliquer et régir
l’utilisation des produits de combustion, de gaz combustible et des
appareils de chauffage. L’organisme local qui en est responsable
saura vous conseiller à cet égard.
Le fonctionnement à feu direct de cet appareil signifie que tous
les produits de combustion se retrouvent dans l’air ambiant.
Même si l’efficacité de combustion de l’appareil de chauffage est
presque complète, il produit quand même de petites quantités
de monoxyde de carbone. Le monoxyde de carbone (appelé CO)
est toxique. Notre organisme ne peut en supporter que de faibles
quantités. Il est possible que le CO s’accumule dans le local à
chauffer. Une ventilation inadéquate pourrait ainsi causer la mort.
Les symptômes ressentis en cas de ventilation inadéquate sont les
suivants :
• mal de tête
• étourdissement
• sensation de brûlure au nez et aux yeux
• nausée
• mal de gorge ou bouche sèche
Assurez-vous donc de respecter les conseils au sujet de la
ventilation mentionnés dans ces instructions.
Un appareil à air pulsé signifie que l’air est soufflé dans l’appareil
de chauffage par un ventilateur. La qualité de la combustion
dépend du débit d’air. Par conséquent, l’appareil de chauffage ne
doit pas être modifié ni fonctionner si des pièces sont manquantes.
Dans le même ordre d’idée, les systèmes de sécurité ne doivent pas
être contournés ni modifiés pour faire fonctionner l’appareil.
Lorsque l’appareil de chauffage doit fonctionner en présence
d’autres personnes, l’utilisateur est responsable d’informer
ces dernières des instructions et précautions liées à la
sécurité et de les avertir des dangers inhérents.
PRÉCAUTIONS LIÉES À LA SÉCURITÉ
1. Vérifiez attentivement si l’appareil de chauffage a subi des
dommages. NE FAITES PAS fonctionner un appareil endommagé.
2. NE MODIFIEZ PAS l’appareil de chauffage et ne le faites pas
fonctionner s’il n’est plus dans son état original.
3. Utilisez uniquement du gaz naturel.
4. Utilisez uniquement une alimentation au naturel à ÉLIMINATION DES
ÉMANATIONS. Si vous avez des questions à propos de l’élimination des
émanations, consultez votre détaillant de gaz naturel.
5. Installez les bonbonnes de naturel verticalement (robinet de fermeture
vers le haut). Fixez-les comme il convient de sorte qu’ils ne puissent se
décrocher accidentellement et protégez-les contre les dommages.
6. Placez les réservoirs de gaz naturel à une distance minimale
(aux États-Unis) de 2,13 m (7 pi) ou (au Canada) de 3 m (10 pi)
de l’appareil de chauffage et n’orientez pas l’échappement
directement vers les réservoirs.
7. IMPORTANT : Utilisez uniquement le tuyau et le régulateur fourni
avec l’appareil. Faites correspondre la bande de couleur de l’étiquette
fixée au tuyau à la couleur de l’étiquette située près du raccord
d’entrée de gaz naturel sur l’appareil. Inspectez le tuyau avant chaque
utilisation de l’appareil de chauffage. En cas d’abrasion, d’usure
excessive ou de coupure, remplacez le tuyau par l’ensemble de tuyaux
recommandé avant d’utiliser l’appareil de chauffage.
8. Pour utilisation intérieure seulement. La ventilation doit être
adéquate. Figure 1. (voir également « Précautions liées au
fonctionnement »).
9. Si une odeur de gaz est détectée, ARRÊTEZ IMMÉDIATEMENT
l’appareil de chauffage jusqu’à ce que la source d’émission du gaz
ait été localisée et colmatée. Veuillez lire le feuillet « Substance
odorante et gaz naturel » ci-joint pour obtenir plus de précisions
relatives à la détection des fuites de gaz naturel.
10. Installez l’appareil de chauffage de façon à ce qu’il ne soit pas
exposé à l’eau.
11. Conservez un écart minimal entre l’appareil et tout matériel
combustible (tel que du papier). Figure 2.
12. En raison des températures élevées de la surface et de l’échappement,
les adultes et les enfants doivent respecter les distances de sécurité
pour éviter des brûlures et l’inflammation des vêtements.
13. Utilisez uniquement sur des surfaces stables et de niveau.
14. N’utilisez pas l’appareil avec des conduits d’air. N’obstruez pas
l’entrée et la sortie d’air.
15. N’utilisez qu’avec l’alimentation électrique spécifiée. Le
raccordement électrique et la mise à la terre doivent être
conformes au Code national de l’électricité - ANSI/NFPA 70 (aux
États-Unis) - et à la norme CSA C22.1, partie 1 du Code canadien
de l’électricité (au Canada).
16. N’utilisez qu’avec une prise ou une rallonge mise à la terre munie
de trois broches.
17. Ne déplacez pas l’appareil, ne le touchez pas et n’essayez pas
d’en faire l’entretien alors qu’il est chaud.
18. Vous ne devez jamais ajuster la hauteur du tube de combustion
de l’appareil de chauffage lorsque l’appareil est chaud
ou fonctionne. Les réglages de hauteur doivent être faits
uniquement lorsque l’appareil n’est pas chaud au toucher.
19. Utilisez l’appareil en observant les codes de sécurité en vigueur
localement ou référez-vous aux normes relatives à l’entreposage et à
la manutention des produits de pétrole liquéfiés ANSI/NFPA 58 et CSA
B149.1 du Code d’installation du gaz naturel et du gaz naturel.
Ouverture Ouverture
Appareil de chauffage près du plancher près du plafond
Air pulsé (HS170NG) 3 pi2 (3 ft2) 3 pi2 (3 ft2)
Figure 2
ÉCART MINIMUM : entre l’appareil et tout matériel combustible.
Écart Air pulsé HS170NG
Du plancher ............................................ 0 pi (0 ft)
De la sortie ............................................. 6 pi (6 ft)
Des côtés ................................................2 pi (2 ft)
Du dessus ............................................... 3 pi (3 ft)
Placez l’appareil à 3 m (10 pi) des toiles en tissu ou en plastique
ou des revêtements similaires et fixez-les afin d’empêcher tout
battement ou mouvement causé par le vent.
Figure 1
VENTILATION : Ouvertures minimales requises
NE JAMAIS LAISSER LE CHAUFFNE JAMAIS LAISSER LE CHAUFFNE JAMAIS LAISSER LE CHAUFFAGE SANS SURAGE SANS SURAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!VEILLANCE PENDANT LE BRÛLAGE!VEILLANCE PENDANT LE BRÛLAGE!
Force-Air Natural Gas Construction HeaterOperating Instructions and Owner’s Manual 4
ODEUR DU GAZ COMBUSTIBLE
Des additifs odorants ont été ajoutés au gaz natural gas
liquéfié et au gaz naturel dans le but de faciliter la détection
de fuites.
Vous devriez remarquer une odeur de gaz combustible s’il
y a une fuite. Comme le gaz natural gas (liquéfié) est plus
lourd que l’air, l’odeur de gaz se détecte plus facilement près
du sol. TOUTE ODEUR DE GAZ EST UN SIGNAL QU’IL FAUT
INTERVENIR IMMÉDIATEMENT !
Ne prenez aucune mesure qui provoquerait l’allumage des
vapeurs de gaz. N’utilisez aucun interrupteur électrique. Ne
tirez sur aucune source d’alimentation électrique ou rallonge
électrique. N’allumez pas d’allumettes ni aucune source de
flamme. N’utilisez pas votre téléphone.
Faites évacuer immédiatement toute personne se trouvant
dans l’immeuble.
Fermez tous les robinets d’alimentation du réservoir de gaz
natural gas (liquéfié) ou de la bonbonne, ainsi que le robinet
d’alimentation principale situé sur le compteur, si vous utilisez
du gaz naturel.
Le gaz natural gas (liquéfié) est plus lourd que l’air et peut
s’accumuler dans les endroits près du sol. Si vous croyez qu’il y a
une fuite de gaz natural gas, éloignez-vous des endroits plus bas.
Utilisez le téléphone d’un voisin et communiquez avec votre
fournisseur en gaz combustible et votre service d’incendies.
Ne retournez pas dans l’immeuble ou dans le secteur.
N’entrez pas dans l’immeuble et restez-en à l’écart jusqu’à ce que
le personnel du service des incendies ou le fournisseur en gaz
combustible ait confirmé que l’endroit ne comporte aucun risque.
EN DERNIER LIEU, laissez le personnel du service des
incendies ou d’approvisionnement en gaz combustible vérifier
si du gaz s’échappe. Assurez-vous qu’ils aient aéré l’immeuble
avant d’y retourner. Le personnel d’entretien expérimenté doit
colmater toute fuite, vérifier la présence d’autres fuites, puis
se charger d’allumer l’appareil pour vous.
SUBSTANCE ODORANTE AUCUNE ODEUR
DÉCELÉE
Certaines personnes ne détectent pas bien les odeurs. Il est
donc possible que certaines personnes ne puissent sentir la
substance odorante ajoutée au gaz natural gas (liquéfié) ou
au gaz naturel. Vous devez savoir si vous arrivez à déceler
l’odeur de cette substance dans le gaz combustible.
Apprenez à reconnaître l’odeur du gaz natural gas et celle du
gaz naturel. Pour ce faire, les détaillants de gaz natural gas
(liquéfié) locaux seront heureux de vous fournir un feuillet
comprenant une pastille à humer. Servez-vous de cette pastille
AVERTISSEMENT RELATIF AUX SUBSTANCES ODORANTES
AVERTISSEMENT
Risque d’asphyxie
Cet appareil ne doit pas être utilisé pour le chauffage de locaux où demeurent des gens.
Ne l’utilisez pas dans des endroits non aérés.
Le débit de chaleur et d’air de ventilation ne doit pas être obstrué.
Le processus de combustion de cet appareil exige un apport adéquat en air de ventilation.
Consultez la rubrique portant sur les spécifications techniques dans le manuel de l’appareil ou sur la plaque de données de
l’appareil, ou communiquez avec le fabricant pour obtenir les renseignements relatifs aux exigences en apport d’air de ventilation
pour la combustion.
Le processus de combustion ne peut s’effectuer correctement si l’apport en air de ventilation est insuffisant.
Une combustion inadéquate produit des émanations nocives de monoxyde de carbone pouvant entraîner des troubles de san
graves, voire mortels. Les symptômes d’empoisonnement au monoxyde de carbone sont les maux de tête, les étourdissements et
la difficulté respiratoire.
pour vous aider à reconnaître l’odeur de gaz combustible.
Le tabagisme peut nuire à votre faculté olfactive. Votre facilité
à déceler une odeur quelconque peut s’estomper si vous
demeurez un certain temps dans un endroit où cette odeur
est présente. La présence d’animaux dans des endroits clos
peut aussi masquer l’odeur du gaz combustible.
La substance odorante contenue dans le gaz natural
gas (liquéfié) et le gaz naturel est incolore et, selon
certaines circonstances, son odeur pourrait s’estomper.
En cas de fuite souterraine, le déplacement du gaz dans le
sol peut filtrer l’odeur.
Portez toujours attention à la moindre odeur de gaz. Si
une odeur de gaz persiste, même si elle est minime, agissez
comme s’il s’agissait d’une fuite importante. Intervenez
immédiatement tel que décrit précédemment.
ATTENTION - POINTS ESSENTIELS À RETENIR !
Le gaz natural gas (liquéfié) dégage une odeur particulière.
Apprenez à reconnaître cette odeur. Consultez les rubriques
Odeur du gaz combustible et Substance odorante, ci-dessus.
Même si vous n’avez pas été formé pour effectuer l’entretien et la
réparation de l’appareil, soyez TOUJOURS attentif aux odeurs que
dégagent le gaz natural gas (liquéfié) et le gaz naturel.
Si vous n’êtes pas formé pour procéder à l’entretien et à
la réparation des appareils au gaz natural gas (liquéfié),
ne tentez pas d’allumer l’appareil, de le réparer ou
de l’entretenir, ni d’apporter des réglages au système
d’alimentation en gaz natural gas de l’appareil.
Peu importe les conditions, une bonne pratique de sécurité
consiste à sentir de temps à autre autour de l’appareil, des
raccords, du tuyau et autres éléments. Si vous décelez la
moindre odeur de gaz, COMMUNIQUEZ IMMÉDIATEMENT
AVEC VOTRE FOURNISSEUR EN GAZ COMBUSTIBLE.
N’ATTENDEZ PAS !
NE JAMAIS LAISSER LE CHAUFFNE JAMAIS LAISSER LE CHAUFFNE JAMAIS LAISSER LE CHAUFFAGE SANS SURAGE SANS SURAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!VEILLANCE PENDANT LE BRÛLAGE!VEILLANCE PENDANT LE BRÛLAGE!
Force-Air Natural Gas Construction Heater Operating Instructions and Owner’s Manual
5
INSTRUCTIONS DE FONCTIONNEMENT
AVANT LE FONCTIONNEMENT
1. Vérifiez soigneusement tout dommage qu’aurait pu subir
l’appareil de chauffage pendant l’expédition. Si vous en
découvrez, avertissez immédiatement le fabricant.
2. Respectez toutes les « Précautions ».
3. Branchez le raccord POL (filet à gauche) du tuyau et du
régulateur en tournant l’écrou POL en sens anti-horaire dans
la sortie du robinet de la bonbonne de gaz naturel, puis
serrez-le avec une clé.
4. Raccordez le tuyau à l’appareil de chauffage en tournant le
raccord dans le sens des aiguilles d’une montre.
5. Serrez fermement toutes les connexions de gaz.
6. Ouvrez le robinet de gaz de la bonbonne et vérifiez toutes
les connexions au moyen d’un mélange d’eau et de savon.
N’UTILISEZ PAS DE FLAMME.
7. Raccordez le cordon d’alimentation à une source
d’alimentation électrique de 115 V, 60 Hz, 1 Ø, mise à la terre
comme il se doit.
8. Lorsque vous utilisez une rallonge électrique, assurez-vous
que celle-ci comporte trois fils (mis à la terre) de dimension
appropriée.
HS170NG DÉMARRAGE
1. Ouvrez lentement le robinet principal de la bonbonne
de natural gas afin de prévenir la fermeture du clapet
limiteur de débit.
2. Réglez le thermostat en position maximale. L’appareil de
chauffage s’allumera automatiquement.
3. Réglez le thermostat à la température désirée. L’appareil
de chauffage se mettra en fonction et s’arrêtera
automatiquement selon les variations de température
dans la zone chauffée.
ARRÊT
1. Fermez le robinet sur la bonbonne de gaz naturel.
2. Laissez l’appareil fonctionner jusqu’à ce que tout le gaz
dans le tuyau ait brûlé.
3. Debranchez le chauffage de l'alimentation electrique.
Redémarrer après arrêt de sécurité
1. Fermez le robinet sur la bonbonne de gaz naturel.
2. Laissez l’appareil fonctionner jusqu’à ce que tout le gaz
dans le tuyau ait brûlé.
3. Débranchez le cordon d’alimentation.
REDÉMARRAGE APRÈS UN ARRÊT D’URGENCE
1. Fermez complètement le robinet sur la bonbonne de gaz
naturel. Débranchez l’appareil de chauffage.
2. Attendez cinq minutes.
3. Recommencez la procédure « Démarrage ».
ENTRETIEN ET ENTREPOSAGE
1. L’appareil de chauffage doit être vérifié avant chaque utilisation
et au moins une fois par année, par un technicien qualifié.
3. Coupez l’alimentation en gaz naturel quand l’appareil n’est
pas utilisé.
ENTREPOSAGE
Un appareil de chauffage qui a été modifié ou qui ne
fonctionne pas correctement risque d’être une cause de
dangers.
La flamme reste dans l’appareil de chauffage.
La flamme a une teinte bleue avec des pointes de
couleur jaune.
Il n’y a pas de forte odeur désagréable, ni de sensation
de brûlure aux yeux, ni de malaise physique en général.
Il n’y a pas de production de fumée ou de suie à
l’intérieur ou à l’extérieur de l’appareil de chauffage.
Il ne se produit pas d’arrêts imprévus ou inexpliqués de
l’appareil.
La liste des pièces et le schéma de câblage présentent
l’appareil de chauffage tel qu’il a été construit. N’utilisez pas
un appareil de chauffage qui diffère de ce qui est illustré.
N’utilisez à cet effet que le tuyau flexible, le régulateur et
le raccord de bonbonne (appelé raccord POL) fournie avec
l’appareil de chauffage. IMPORTANT : Faire correspondre la
bande de couleur de l’étiquette fixée au tuyau à la couleur
de l’étiquette située près du raccord d’entrée de gaz natural
gas. N’utilisez aucun élément de substitution. Sur cet appareil
de chauffage, le régulateur doit être réglé tel qu’indiqué à la
rubrique « Spécifications ». Si vous avez un doute au sujet du
réglage du régulateur, faites-le vérifier.
Les produits couverts par la garantie seront réparés sans frais,
pièces et main-d’œuvre comprises. Veuillez joindre une courte
description de la nature du problème avec la date, le lieu et la
preuve d’achat.
Si un appareil de chauffage
ne fonctionne pas
correctement,
il doit être réparé, mais
seulement
par un technicien formé et
expérimenté.
Les produits couverts par la garantie seront réparés sans frais,
pièces et main-d’œuvre comprises. Veuillez joindre une courte
description de la nature du problème avec la date, le lieu et la
preuve d’achat.
Les produits non couverts par la garantie seront réparés aux
frais (pièces et main-d’œuvre) du client.
MISE EN GARDE: Le défaut de débrancher l'appareil de
l'alimentation électrique peut provoquer un fonctionnement
inattendu.
NE JAMAIS LAISSER LE CHAUFFNE JAMAIS LAISSER LE CHAUFFNE JAMAIS LAISSER LE CHAUFFAGE SANS SURAGE SANS SURAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!VEILLANCE PENDANT LE BRÛLAGE!VEILLANCE PENDANT LE BRÛLAGE!
Force-Air Natural Gas Construction HeaterOperating Instructions and Owner’s Manual 6
SCH MA DE C´B LAGE
ModŁle n” H S17 0 N G
COULEUR
HS170NG - SCH MA DE C´B LAGE
LONGUEUR DE
Blanc 18 cm (7 po) Robinet
Noir 15 cm (6 po)
Si du câblage dÊorigine fourni avec lÊappareil de chauffage doit
être remplacé, il faut utiliser du câblage de type AWG 105 C
ou un équivalent, à moins dÊindication contraire.
(*type SF2-200, **SGI 250 C).
Interrupteur
Rouge (Haute 42 cm Interrupteur
commande max.
(16,5po) température)
Bloc de raccordement
Bloc de raccordement
Robinet
42 cm Rouge (Haute Interrupteur
(16,5po) commande max température)
Orange 28 cm Commande de
(11 po)
Vert 18 cm Commande de
(7 po)
Rouge
Bloc de
raccordement
Bougie dÊallumage
(Allumage)
Ground
18 cm Commande de Bloc de
(7 po)
Blanc
raccordement
Commande de 15 cm Bloc de
(6 po)
Noir
raccordement
15 cm Commande de Bloc de
(6 po) raccordement
AIS-JE BESOIN?
DE QUELLE QUANTIT DE CHALEUR
Calibre minimum recommandØ
pour rallonges
Tableau de calibre de c ble AWG
Longueur de la rallonge en pieds
25 50
Plaque
d identification
120 V A 100 15 0
5-6 18 16 14 12
6-8 18 16 12 10
8-12 18 14 12 10
10-12 16 14 10 8
12-14 16 12 10 8
Pour des raisons dÊéconomie, il est important que le
rendement corresponde aux besoins. Mais les besoins
en matière de chaleur varient souvent. Par exemple,
beaucoup de chaleur est habituellement requise pour
réchauffer des objets que pour les conserver au chaud.
Dans le même ordre dÊidées, la température de lÊair
extérieur augmente habituellement durant la journée; la
demande en chaleur est donc plus grande durant la nuit
que durant la journée. Une approximation de la chaleur
requise peut être établie à lÊaide du tableau ci-dessous.
du personnel.
Pieds cubes
(”C/”F)* d espace -6,6 ”C
vation de tempØrature requise
1,0 ”C 4,4 ”C 10 ”C
chau ffØ
(20 ”F) (30 ”F) (40 ”F) (50 ”F)
5 000 14 000 20 000 27 999 34 000
7 000 19 000 28 000 38 000 47 000
10 000 27 000 40 000 54 000 67 000
AVERTISSEMENT : Lors de lÊutilisation dÊun ap-
pareil de chauffage contrôlé par thermostat, sa zone
dÊéchappement doit être p rotégée et des avertissements
40 000 15 000 60 000 80 000 100 000
54 000 20 000 80 000 107 000 133 000
80 000 30 000 120 000 160 000 200 000
50 000 133 000 200 000 266 000 333 000
BTU PAR HEURE REQUIS
CODE COULEUR LÉGENDE
B NOIR
L BLUE
G VERT
O ORANGE
R ROUGE
W BLANC
CONSEIL TERMINAL
BORNEY
CONN. MÂLE
CONN. FEMELLE
YY
Y
NE JAMAIS LAISSER LE CHAUFFNE JAMAIS LAISSER LE CHAUFFNE JAMAIS LAISSER LE CHAUFFAGE SANS SURAGE SANS SURAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!VEILLANCE PENDANT LE BRÛLAGE!VEILLANCE PENDANT LE BRÛLAGE!
Force-Air Natural Gas Construction Heater Operating Instructions and Owner’s Manual
7
Modèle # HS170NG LISTE DES PIÈCES
Article N° art. Description Qté
121735 Coque extérieure - Modèle MH 1
222249 Cylindre central 1
322261 Ensemble de l’orifice 1
42114 6 Ensemble porte-flamme 1
526168 Interrupteur de limite haute de la course 1
623038 Écrou de l’orifice 1
727095 Poignée 1
827094 Clips de montage de la poignée 2
926 010 Vis de réglage, Nyloc 1
10 26074 Ventilateur 1
11 22251 Moteur 1
12 22252 Grille, montage d’admission/du moteur 1
13 22262 Régulateur, 4" de colonne d’eau 1
14 22263 Connexion à raccord mâle 3/8MPT x
3/8 SAE FLR
1
15 22264 Électrovanne, Goyen 1
16 22265 Raccord étroit 1
17 22266 Ensemble de tube à carburant 1
18 21084 Electrode, Spark 1
19 24340 Support de montage du thermostat 1
Article N° art. Description Qté
20 22254 Thermostat 1
21 26070 Support de collier, 5/16 1
22 27808 Commande de la flamme, encapsulée 1
23 21036 Cordon d’alimentation 1
24 28771 Panneau de raccordement 1
25 26223 Réducteur de tension de la bague 1
26 28773 Bouton, réglage du taux de combustion 1
27 22255 Boîtier de commande 1
28 22273 Base, boîtier de commande 1
NE JAMAIS LAISSER LE CHAUFFNE JAMAIS LAISSER LE CHAUFFNE JAMAIS LAISSER LE CHAUFFAGE SANS SURAGE SANS SURAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!VEILLANCE PENDANT LE BRÛLAGE!VEILLANCE PENDANT LE BRÛLAGE!
AVERTISSEMENT
Dangerdelaqualitédel’air
• N’utilisezpascetappareildechauffagepourlechauffagedeslocauxd’habitationhumaine.
• L’utilisationdesappareilsdechauffagedirectdanslesenvironnementsdeconstructionpeutvousexposeràdesniveauxde
CO, CO2, et NO2, qui sont considérés comme dangereux pour la santé et potentiellement mortels.
Ne pas utiliser dans les zones non ventilées.
• Connaissezlessignesd’empoisonnementauCOetCO2.
ǞMaux de tête, brûlure des yeux
ǞVertige, désorientation
ǞDifficultéàrespirer,sensationd’étouffement
• Unéchanged’airdeventilationadéquat(OSHA29CFR1926.57)poursupporterlacombustionetmaintenirunequalitéde
l’airacceptableestfournieselonOSHA29CFRpartie1926.154,ANSIA10.10Exigencesdesécuritépourlesappareilset
équipementsdechauffageportablesettemporairesutilisésdansl’industriedelaconstructionoulesCodesCSApourlegaz
naturel et le gaz propane CSA B149.1.
ǞSurveillerpériodiquementlesniveauxdeCO,deCO2etdeNO2existantssurlesitedeconstruction–àtoutlemoinsau
début du quart de travail et après 4 heures.
ǞPrévoirunéchanged’airdeventilation,soitnatureloumécanique,telquerequispourmaintenirunequalitédel’air
intérieur acceptable..
Moyenne pondérée dans le temps sur 8
heures, États-Unis
(OSHA 29 CFR 1926.55 App A)
Moyenne pondérée dans le temps sur 8
heures, Canada Directives SST de Work-
Safe BC partie 5.1 et Règlement sur les
milieux de travail en Ontario 833
CO 50 parties par million
CO25000 parties par million
NO2
É.-U.-Limitedeplafond(limited’exposi-
tionàcourtterme=15minutes)
DirectivesdeSSTCanadaSTEL(15
minutesRég.833/1heureWSBC)de
WorkSafe BC partie 5.1 et Règlement sur
les milieux de travail en Ontario 833
CO 100 parties par million
CO215000 parties par million (WSBC)
3000 parties par million (Reg 833)
NO25 parties par million 1.0 parties par million (WorkSafeBC)
5.0 parties par million (Reg 833)
• Assurez-vousqueledébitd’échanged’airdecombustionetdeventilationnepeutpasêtreobstrué.
• Laventilationpeutdevoirêtreaugmentéeàmesurequelebâtiment«durcit»lorsdesphasesdeconstruction.
NE JAMAIS LAISSER LE CHAUFFNE JAMAIS LAISSER LE CHAUFFNE JAMAIS LAISSER LE CHAUFFAGE SANS SURAGE SANS SURAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!VEILLANCE PENDANT LE BRÛLAGE!VEILLANCE PENDANT LE BRÛLAGE!
THIS PAGE INTENTIONALLY LEFT BLANK
ESTA PÁGINA INTENCIONALMENTE SE DEJA EN BLANCO
CETTE PAGE A ÉTÉ INTENTIONNELLEMENT LAISSÉE VIERGE
NE JAMAIS LAISSER LE CHAUFFNE JAMAIS LAISSER LE CHAUFFNE JAMAIS LAISSER LE CHAUFFAGE SANS SURAGE SANS SURAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!VEILLANCE PENDANT LE BRÛLAGE!VEILLANCE PENDANT LE BRÛLAGE!
THIS PAGE INTENTIONALLY LEFT BLANK
ESTA PÁGINA INTENCIONALMENTE SE DEJA EN BLANCO
CETTE PAGE A ÉTÉ INTENTIONNELLEMENT LAISSÉE VIERGE
NE JAMAIS LAISSER LE CHAUFFNE JAMAIS LAISSER LE CHAUFFNE JAMAIS LAISSER LE CHAUFFAGE SANS SURAGE SANS SURAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!VEILLANCE PENDANT LE BRÛLAGE!VEILLANCE PENDANT LE BRÛLAGE!
HS170NG
GUIDE D’UTILISATION ET
MANUEL DU PROPRIÉTAIRE
LISEZ SOIGNEUSEMENT LES INSTRUCTIONS : Lisez et observez toutes les instructions. Conservez ces
instructions dans un endroit sécuritaire pour vous y référer ultérieurement. Ne permettez pas à quiconque
n’ayant pas lu les présentes instructions d’assembler, d’allumer, de régler ou de faire fonctionner l’appareil.
Modèle #
AVERTISSEMENT :
N’UTILISEZ QUE LES PIÈCES DE REMPLACEMENT DU FABRICANT. L’UTILISATION
D’AUTRES PIÈCES RISQUE DE CAUSER DES BLESSURES ET LA MORT. LES PIÈCES DE
REMPLACEMENT NE SONT OFFERTES QUE PAR LE FABRICANT ET DOIVENT ÊTRE
INSTALLÉES PAR UNE ENTREPRISE SPÉCIALISÉE.
INFORMATIONS SUR LA COMMANDE DE PIÈCES :
ACHATS : Les accessoires peuvent être achetés chez n’importe quel revendeur local
Mr. Heater ou directement à l’usine.
POUR OBTENIR DES INFORMATIONS SUR LE SERVICE
Veuillez appeler sans frais le 866-447-2194 • www.HeatStar.com
Nos heures d’ouverture sont de 8 h 00 à 17 h HE, du lundi au vendredi.
Adressez vos courriels à : techservice@enerco-HeatStar.com
Veuillez indiquer le numéro du modèle, la date d’achat et la description du problème
dans toutes vos communications avec nous.
GARANTIE LIMITÉE
L’entreprise garantit ce produit contre tout défaut de matériel ou de main-d’œuvre, dans des
conditions d’utilisation normale et adéquate, conformément aux instructions de l’entreprise, pour une
période de un an à compter de la date de livraison à l’acheteur. L’entreprise réparera ou remplacera,
à sa discrétion, les produits retournés port payé par l’acheteur au fabricant dans la période de un an
et jugés par l’entreprise comme présentant des défauts de matériel ou de main-d’œuvre.
Si une pièce est endommagée ou manquante, téléphonez à notre service de soutien technique
au 866-447-2194.
Envoyez toutes les demandes de garantie au service à la clientèle, HeatStar, Inc., 4560 W. 160th
St., Cleveland, Ohio 44135. Incluez votre nom, l’adresse et le numéro de téléphone et aussi les
détails concernant la demande. Nous fournir également la date d’achat et le nom et l’adresse du
concessionnaire auprès duquel vous avez acheté notre produit.
Ce qui est énoncé ci-dessus constitue la responsabilité totale de l’entreprise. Il n’existe aucune autre
garantie, expresse ou tacite. Plus précisément, il n’y a aucune garantie concernant l’adéquation à une
utilisation particulière ni aucune garantie concernant la qualité marchande. En aucun cas l’entreprise
ne sera tenue responsable des retards causés par des défectuosités, ni des dommages indirects, ni des
dépenses encourues sans son consentement écrit, quelle que soit leur nature. Le coût de la réparation
ou du remplacement sera le seul recours possible en cas de violation de garantie. Il n’y a aucune
garantie contre une transgression de ce genre ni aucune garantie tacite découlant des usages du
commerce ou de la façon habituelle d’échanger. La présente garantie ne s’applique à aucun produit
qui a été réparé ou modifié par d’autres que le fabricant si cela influe de quelque façon que ce soit
sur la condition de l’appareil ou son fonctionnement, selon notre jugement.
Certains États ou provinces ne permettent pas d’exclure ou de limiter les dommages indirects
ou subséquents. Par conséquent, les limitations ou exclusions ci-dessus mentionnées ne vous
concernent peut-être pas. La présente garantie vous accorde des droits juridiques précis, mais
vous pourriez avoir d’autres droits qui varient selon la province ou l’État.
Mr. Heater, Inc., se réserve le droit de modifier en tout temps, sans préavis ni obligation, les
couleurs, spécifications, accessoires, matériaux et modèles.
HeatStar, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 800-251-0001
HeatStar est une marque déposée de Enerco Group, Inc
© 2019, Enerco Group, Inc. Tous droits réservés
ENREGISTREMENT DU PRODUIT : Nous vous remercions pour votre achat.
Veuillez vous connecter à http://www.egiregistration.com pour enregistrer votre produit.
NE JAMAIS LAISSER LE CHAUFFNE JAMAIS LAISSER LE CHAUFFNE JAMAIS LAISSER LE CHAUFFAGE SANS SURAGE SANS SURAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE!VEILLANCE PENDANT LE BRÛLAGE!VEILLANCE PENDANT LE BRÛLAGE!
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

HeatStar HS170NG Le manuel du propriétaire

Catégorie
Chauffe-eau
Taper
Le manuel du propriétaire

dans d''autres langues