KitchenAid 30" Range with the FIT System Le manuel du propriétaire

Catégorie
Hottes
Taper
Le manuel du propriétaire

Ce manuel convient également à

30" (76.2 CM) RANGE HOOD
Installation Instructions and Use & Care Guide
For questions about features, operation/performance, parts, accessories or service,
call: 1-800-253-1301 or visit our website at www.whirlpool.com
In Canada, call 1-800-807-6777 or visit our website at www.whirlpool.ca
HOTTE D’ASPIRATION DE 30" (76,2 CM)
Instructions d’installation et Guide d’utilisation et d’entretien
Au Canada, pour assistance, installation ou service, composer le 1-800-807-6777 ou visiter notre site Web à www.whirlpool.ca
Table of Contents/Table des matières .....................................2
Model/Modèle:
UXT2030AD
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONL
Y.
IMPOR
TANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISA
TION RÉSIDENTIELLE UNIQUEMENT
.
LI319E/W10646400E
2
TABLE OF CONTENTS TABLE DES MATIÈRES
RANGE HOOD SAFETY
You can be killed or seriously injured if you don't immediately
You
can be killed or seriously injured if you don't
follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
RANGE HOOD SAFETY .................................................................2
INSTALLATION REQUIREMENTS .................................................4
Tools and Parts ............................................................................. 4
Location Requirements ................................................................4
Venting System ............................................................................5
Electrical Requirements ...............................................................6
INSTALLATION INSTRUCTIONS ...................................................7
RANGE HOOD USE ......................................................................10
Range Hood Controls ................................................................10
RANGE HOOD CARE ...................................................................11
Cleaning .....................................................................................11
WIRING DIAGRAM .......................................................................12
ASSISTANCE OR SERVICE .........................................................13
In the U.S.A. ...............................................................................13
In Canada ...................................................................................13
WARRANTY ..................................................................................14
SÉCURITÉ DE LA HOTTE DE CUISINIÈRE ...............................15
EXIGENCES D’INSTALLATION ...................................................17
Outillage et pièces ......................................................................17
Exigences d’emplacement .........................................................17
Circuit d’évacuation ...................................................................18
Spécifications électriques ..........................................................19
INSTRUCTIONS D’INSTALLATION .............................................20
UTILISATION DE LA HOTTE .......................................................23
Commandes de la hotte de cuisinière .......................................23
ENTRETIEN DE LA HOTTE .........................................................24
Nettoyage ...................................................................................24
SCHÉMA DE CÂBLAGE ...............................................................25
ASSISTANCE OU SERVICE .........................................................26
Au Canada ..................................................................................26
GARANTIE .....................................................................................27
3
State of California Proposition 65 Warnings:
WARNING: This product contains one or more chemicals known to the State of California to cause cancer.
WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other
reproductive harm.
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
4
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting
installation. Read and follow the instructions provided
with any tools listed here.
Tools needed
Parts supplied
Remove parts from package. Check that all parts are included.
Parts needed
For 7" (17.8 cm) round vented installations
Optional accessories
* For information on ordering, see the “Assistance or Service”
section.
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
It is the installer’s responsibility to comply with installation
clearances specified on the model/serial/rating plate.
The model/serial/rating plate is located inside the range
hood on the left wall.
Range hood location should be away from strong draft
areas, such as windows, doors, and strong heating vents.
Cabinet opening dimensions that are shown must be
used. Given dimensions provide minimum clearance.
Consult the cooktop/range manufacturer installation
instructions before making any cutouts.
This range hood is recommended for use with cooktops
with a maximum total rating of 40,000 BTUs or less.
Grounded electrical outlet is required. See “Electrical
Requirements” section.
All openings in ceiling and wall where range hood will
be installed must be sealed.
These range hoods are factory set for vented installations.
Models that are capable of being installed as non-vented
(recirculating) require charcoal filters. See the “Assistance or
Service” section for information on ordering charcoal filters.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title
24 CFR, Part 328 (formerly the Federal Standard for Mobile
Home Construction and Safety, title 24, HUD, Part 280),
or when such standard is not applicable, the standard for
Manufactured Home Installation 1982 (Manufactured Home
Sites, Communities and Setups) ANSI A225.1/NFPA 501A
or latest edition, or with local codes.
Product Dimensions
Caulking gun and weatherproof
caulking compound
Jigsaw or keyhole saw
Flat-blade
screwdriver
Drill with ¹⁄₈"
(3 mm), ¹⁄₂"
(13 mm)
and 1¹⁄₄"
(3 cm) bits
Wire stripper
#2 Phillips
screwdriver
Metal snips
Pencil
#8-18 x ⁵⁄₈"
(4.2 x 16 mm)
truss-head screws
#8-18 x 1"
(4.2 x 25 mm)
flat-head screws
Drywall
anchors
Mounting
brackets
7" (17.8 cm) round vent
mounting plate
Part Number W10388168*
UL Listed/CSA
Approved
wire connectors
120V, 75W
maximum,
type E26
lamp
7" (17.8 cm) round
metal vent system with
wall or roof cap
7" (17.8 cm)
round damper
Part Number
W10355451*
Vent clamps as
required
Power
cord kit
Part Number
W10355452*
Stainless steel cleaner
and polish
Part Number 31462A*
1"
(2.5 cm)
4¹⁵⁄₁₆"
(12.5 cm)
6⁹⁄₁₆" (16.7 cm)
29¹⁵⁄₁₆" (76.0 cm)
18⁵⁄₈"
(47.3 cm)
1¹⁄₂"
(3.8 cm)
9"
(22.9 cm)
2"
(5.1 cm)
1"
(2.5 cm)
5
Installation Clearances
Venting System
Venting Methods
NOTES:
Flexible vent is not recommended. Flexible vent
creates both back pressure and air turbulence
that greatly reduce performance.
The vent system is optional for this model.
Vent system can terminate either through the roof or wall.
Use 7" (17.8 cm) or larger round vent with a maximum length
of 50 ft (15.2 m) for vent system.
Top Venting Wall Venting
A
B
A
B
A. 7" (17.8 cm) round vent
through roof (purchased
separately)
B. Roof cap with damper
(purchased separately)
A. 7" (17.8 cm) round vent out
the top and through the wall
(purchased separately)
B. Wall cap with damper
(purchased separately)
Cold Weather Installations
An additional backdraft damper should be installed to
minimize backward cold air flow and a thermal break should
be installed to minimize conduction of outside temperatures
as part of the vent system. The damper should be on the cold
air side of the thermal break.
The break should be as close as possible to where the
vent system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup
air systems when using ventilation systems greater than
specified CFM of air movement. The specified CFM varies
from locale to locale. Consult your HVAC professional
for specific requirements in your area.
Venting Requirements
Vent system must terminate to the outdoors.
Do not terminate the vent system in an attic
or other enclosed area.
Do not use a 4" (10.2 cm) laundry-type wall cap.
Use 7" (17.8 cm) round metal vent. Rigid metal
vent is recommended. Plastic or metal foil vent
is not recommended.
The length of vent system and number of elbows should
be kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61 cm) of straight
vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps or duct tape to seal all joints in the vent system.
The vent system must have a damper. If roof or wall cap has
a damper, do not use damper supplied with the range hood.
Use caulking to seal exterior wall or roof opening
around the cap.
B
A
C
D
E
A. 24" (61 cm) minimum distance from electric cooking surface
24" (61 cm) minimum distance from gas cooking surface
30" (76.2 cm) suggested maximum above the cooking surface
B. 18" (45.7 cm) minimum clearance - upper cabinet to countertop
C. 30" (76.2 cm) minimum cabinet opening width
D. 12" (30.5 cm) cabinet depth
E. 36" (91.4 cm) base cabinet height
6
Calculating Vent System Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
Vent System
Vent Piece
45° elbow 2.5 ft (0.8 m)
90° elbow 5 ft (1.5 m)
7" (17.8 cm) wall cap 0 ft (0 m)
Example vent system
1 - 90° elbow = 5 ft (1.5 m)
1 - wall cap = 0 ft (0 m)
8 ft (2.4 m) straight = 8 ft (2.4 m)
System length = 13 ft (3.9 m)
Maximum Recommended Length
7" (17.8 cm) Round Vent = 50 ft (15.2 m)
Electrical Requirements
Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA
70 (latest edition) or CSA Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition),
and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that
the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 volt, 60 Hz., AC only, 15-amp, fused
electrical circuit is required.
If the house has aluminum wiring, follow
the procedure below:
1. Connect a section of solid copper wire
to the pigtail leads.
2. Connect the aluminum wiring to the added section
of copper wire using special connectors and/or tools
designed and UL Listed for joining copper to aluminum.
Follow the electrical connector manufacturer’s recommended
procedure. Aluminum/copper connection must conform
with local codes and industry accepted wiring practices.
Wire sizes and connections must conform with the rating
of the appliance as specified on the model/serial/rating
plate. The model/serial/rating plate is located inside the
range hood on the left wall.
Wire sizes must conform to the requirements of the National
Electrical Code, ANSI/NFPA 70 (latest edition) or CSA
Standards C22. 1-94, Canadian Electrical Code, Part 1
and C22.2 No. 0-M91 (latest edition), and all local codes
and ordinances.
Wall cap
90˚ elbo
w
2 ft (0.6 m)
6 ft (1.8 m)
7
INSTALLATION INSTRUCTIONS
NOTES:
Depending on your model, determine which venting
method to use: roof or wall.
It is recommended that the vent system be installed before
the range hood is installed. Go to “Venting System” in the
“Installation Requirements” section if you need assistance.
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for the vent system.
1. Disconnect Power
2. Mark Hole Locations
Align the exterior edge of the mounting brackets
with the exterior edges of the upper cabinet.
IMPORTANT: The brackets should touch the upper cabinet.
With a pencil, mark the upper holes on the brackets.
3. Install Brackets
Using a #2 Phillips screwdriver, install the drywall anchors.
Using #8-18 x 1" (4.2 x 25 mm) flat-head #2 Phillips screws,
install the mounting brackets using the upper holes.
NOTE: For installations to a surface other than drywall,
it is recommended that a qualified contractor determine
the anchoring method.
4. Prepare Range Hood
Set the range hood on its back on a covered surface.
Using a #2 Phillips screwdriver, remove the 7"
(17.8 cm) round vent mounting plate attached
with 3.5 x 9.5 mm screws.
Using a #2 Phillips screwdriver, remove the electrical
box cover.
Using a flat-blade screwdriver, remove the appropriate
power supply knockout.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
8
5. Mark Hole Locations
Lift the range hood into place and insert the mounting bracket
tabs through the slots in the back of the range hood.
Hold the range hood firmly in place with one hand and
bend each mounting tab (A) upward approximately 90°.
Mark the hole at the power supply knockout (B).
Mark the 4 vent hole locations (C) on the top of the range hood.
OPTIONAL: Mark the hole in each mounting tab.
Remove the range hood and set it aside.
6. Mark and Cut Vent Opening
7" (17.8 cm) Round Vent System
Using the 7" (17.8 cm) round vent mounting plate, draw
the vent opening outline on the underside of the cabinet:
- Place the vent mounting plate on the bottom of the
cabinet. Position the edge of the plate with the widest
distance (A) between the hole and edge of the mounting
plate against the wall. Position the side edges of the
mounting plate between the dots marked previously.
IMPORTANT: The widest edge (A) of the vent
mounting plate must be positioned against the wall.
- Trace the 7" (17.8 cm) vent opening (solid line)
on the cabinet bottom.
Using a jigsaw or keyhole saw, cut the vent opening
1" (2.5 cm) larger than the 7" (17.8 cm) hole traced
(dashed line).
7. Drill Electrical Opening
Using a 1
1
/
4
" (3 cm) drill bit, drill the hole in the dot
marked previously at the electrical strain relief.
OPTIONAL: Using a
1
/
8
" (3 mm) drill bit, drill pilot holes
for the dots marked previously at each mounting tab
at an approximate 45° angle in an upward direction.
C
B
A
C
A
90˚
1"
(2.5 cm)
A
9
8. Prepare Range Hood Vents
and Mounting Tabs
Install Strain Relief
Install a UL Listed/CSA Approved
1
/
2
" (13 mm)
strain relief (A).
Mounting Tabs
Start a #8-18 x
5
/
8
" (4.2 x 16 mm) truss-head screw into
the mounting tab (D) on each side of the range hood
as shown in the inset. Insert the screws approximately
2 turns into the mounting tab holes.
7" (17.8 cm) Round Vent Installations
Remove both top knockouts (B and C).
9. Attach Vent Damper or Transition
7" (17.8 cm) Round Vent Mounting Plate
Using (2) short Phillips head screws, install the 7" (17.8 cm)
round vent mounting plate over the vent knockouts
removed in Step 8. Position the wide flange (C) to the front.
NOTE: An optional 7" (17.8 cm) round damper (A),
Part Number W10355451 is available as an accessory.
For information on ordering, see the “Assistance
or Service” section.
If installing the optional round damper, position
it over the round vent mounting plate.
10. Mount Range Hood
Lift the range hood into place, positioning the rear slots
over the mounting brackets.
Using a Phillips screwdriver, push on the screws that
are started into the top mounting tabs and bend the
tabs against the cabinet side walls. Attach the screws
to the cabinet side walls.
IMPORTANT: Do not overtighten the screws.
For direct wire installations, run the home power supply
cable according to the National Electric Code or CSA
standards and local codes and ordinances. There must
be enough wiring from the fused disconnect (or circuit
breaker) box to make the connection in the range hood
electrical terminal box.
Tighten the strain relief screws.
NOTE: Do not reconnect power until the installation
is complete.
OPTIONAL: If you prefer, bend the rear tabs against
the rear of the range hood and attach to the wall using
#8-18 x
5
/
8
" (4.2 x 16 mm) truss-head screws.
11. Connect Vent System
Connect the ventwork to the range hood.
Seal joints with vent clamps or duct tape to make
secure and airtight.
Check that the backdraft dampers work properly.
A
B
C
x2
D
A
B
C
10
12. Make Electrical Connection
Option 1 - Direct Wire Installations
Use a UL Listed/CSA Approved wire connector
and connect the 3 white wires (A) together.
Use a UL Listed/CSA Approved wire connector
and connect the 2 black wires (B) together.
Connect the green (or bare) ground wire (C) from the
power supply to the green ground screw in the electrical
box and tighten the screw securely.
Reinstall the electrical box cover.
Reconnect power.
Option 2 - Power Cord Kit Installations
For optional power cord kit installations, follow the instructions
supplied with the power cord kit. See the “Assistance or
Service” section for information on ordering.
NOTE: Use only with range hood cord connection kits that
have been investigated and found acceptable for use with
this model range hood.
13. Complete the Installation
Install a 120V, 75W maximum, light bulb with
E26 base. See “Replacing the Light Bulb” in
the “Range Hood Care” section.
If removed previously, replace the filter. See “Metal
Grease Filter” in the “Range Hood Care” section.
Check the operation of the range hood fan and light.
See the “Range Hood Use” section.
If the range hood does not operate, check to see whether
a circuit breaker has tripped or a household fuse has blown.
Disconnect the power and check the wiring connections.
NOTE: To get the most efficient use from your new
range hood, read the “Range Hood Use” section.
RANGE HOOD USE
The range hood is designed to remove smoke, cooking
vapors, and odors from the cooktop area. For best results,
start the hood before cooking and allow it to operate several
minutes after the cooking is complete to clear all smoke and
odors from the kitchen.
The hood controls are located on the front panel of
the range hood.
Range Hood Controls
Operating the light
Press the light switch to the left to turn the light On.
Press the light switch to the right to turn the light Off.
Operating the fan
The fan has 2 speeds.
Press the fan switch to the left for Low speed.
Press the fan switch to the right for High speed.
Return the fan switch to the center to turn the fan Off.
A
B
C
WARNING
Fire Hazard
Electrically ground the blower.
Use copper wire.
Connect ground wire to green ground screw in
terminal box.
Failure to do so can result in death, fire, or
electrical shock.
A
C
B
A. Light housing and cover
B. Grease filter retainer
C. Grease filter
A
B
Off
On
Low
Off
High
A. On/Off light switch
B. Fan speed switch
11
RANGE HOOD CARE
Cleaning
IMPORTANT: Clean the hood and grease filters frequently
according to the following instructions. Replace the grease
filter before operating hood.
Exterior Surfaces
IMPORTANT: Do not use soap-filled scouring pads,
abrasive cleaners, cooktop polishing creme, steel wool,
gritty washcloths, or paper towels.
To avoid damage to the stainless steel, do not use cleaners
that contain chlorine.
Cleaning Method:
Liquid detergent or all-purpose cleaner:
Rinse with clean water and dry with a soft, lint-free cloth.
Glass cleaner to remove fingerprints.
For stainless steel models, rub in the direction of the
grain to avoid scratching or damaging the surface.
For stainless steel models, use Stainless Steel Cleaner
and Polish, Part Number 31462A (not included):
See the “Assistance or Service” section to order.
Metal Grease Filter
To Clean the Filter:
1. Remove the screw from the grease filter retainer.
2. Turn the grease filter retainer to release the filter.
3. Wash the metal filter as needed in a dishwasher
or hot detergent solution.
To Replace the Filter:
1. To reinstall the filter, place the back edge of the filter into the
channel at the rear of the hood. Push the filter into place and
turn the filter retainer to secure the filter to the range hood.
2. Replace the screw in the grease filter retainer.
Replacing the Light Bulb
Turn off the range hood and allow the light bulb to cool.
1. Disconnect power.
2. Squeeze the plastic lens cover and remove it from the hood.
3. Screw a 120V, 75W maximum, light bulb with
E26 base into the socket.
4. Replace the lens cover by squeezing the cover
and inserting the tabs into the slots.
5. Reconnect power.
If the new light does not operate, make sure the light bulb
is inserted correctly before calling service.
A
A. Filter retainer
12
WIRING DIAGRAM
0.65 ±10% A
38 ±10% Watts
16.98 ±10% Ohms
9.36 ±10% Ohms
C19
SE116C
Motor Characteristics
Power Supply 120 VAC
Frequency 60 Hz
Amperage
Wattage Rating
Motor Resistance
Brown - White
Brown - Red
Light Switch
On - Off
Motor Switch
Low - Off - High
BK
WH
WH
WH
N
WH
RD
Speed 2
Common
Speed 1
BK
L
GND
Ground
Screw
BR
WH
RD
RD
BK
BR
BK
13
ASSISTANCE OR SERVICE
If you need service
Please refer to the warranty page in this manual.
If you need replacement parts
If you need to order replacement parts, we recommend that
you use only factory specified parts. Factory specified parts
will fit right and work right because they are made with the
same precision used to build every new appliance.
To locate factory specified replacement parts in your area,
call the following customer assistance telephone number
or your nearest designated service center.
In the U.S.A.
Call the Whirlpool Customer eXperience Center toll-free:
1-800-253-1301 or visit our website at www.whirlpool.com.
Our consultants provide assistance with:
Scheduling of service. Whirlpool designated service
technicians are trained to fulfill the product warranty
and provide after-warranty service anywhere in the
United States.
Features and specifications on our full line of appliances.
Referrals to local dealers.
Installation information.
Use and maintenance procedures.
Accessory and repair parts sales.
Specialized customer assistance (Spanish speaking,
hearing impaired, limited vision, etc.).
For further assistance
If you need further assistance, you can write to Whirlpool
Corporation with any questions or concerns at:
Whirlpool Brand Home Appliances
Customer eXperience Center
553 Benson Road
Benton Harbor, MI 49022-2692
Please include a daytime phone number in your correspondence.
In Canada
Call the Whirlpool Canada LP Customer eXperience
Centre toll-free: 1-800-807-6777 or visit our webpage
www.whirlpool.ca.
Our consultants provide assistance with:
Scheduling of service. Whirlpool designated service
technicians are trained to fulfill the product warranty
and provide after-warranty service anywhere in Canada.
Features and specifications on our full line of appliances.
Referrals to local Whirlpool dealers.
Use and maintenance procedures.
Accessory and repair parts sales.
Referrals to local dealers, repair parts distributors,
and service companies. Whirlpool Canada LP designated
service technicians are trained to fulfill the product warranty
and provide after-warranty service anywhere in Canada.
For further assistance
If you need further assistance, you can write to Whirlpool
Canada LP with any questions or concerns at:
Whirlpool Brand Home Appliances
Customer eXperience Centre
Whirlpool Canada LP
200 - 6750 Century Ave.
Mississauga, Ontario L5N 0B7
Please include a daytime phone number in your correspondence.
14
11/14
IF YOU NEED SERVICE:
1. Before contacting us to arrange service, please determine whether your product requires repair.
Some questions can be addressed without service. Please take a few minutes to review the
Troubleshooting or Problem Solver section of the Use and Care Guide, scan the QR code on
the right to access additional resources, or visit www.whirlpool.com/product_help.
2. All warranty service is provided exclusively by our authorized Whirlpool Service Providers.
In the U.S. and Canada, direct all requests for warranty service to:
Whirlpool Customer eXperience Center
In the U.S.A., call 1-800-253-1301. In Canada, call 1-800-807-6777.
If outside the 50 United States or Canada, contact your authorized Whirlpool dealer to determine whether another warranty applies.
WHIRLPOOL
®
MAJOR APPLIANCE
LIMITED WARRANTY
ATTACH YOUR RECEIPT HERE. PROOF OF PURCHASE IS
REQUIRED TO OBTAIN WARRANTY SERVICE.
Please have the following information available when you call the
Customer eXperience Center:
Name, address and telephone number
Model number and serial number
A clear, detailed description of the problem
Proof of purchase including dealer or retailer name and address
ONE YEAR LIMITED WARRANTY
WHAT IS COVERED WHAT IS NOT COVERED
For one year from the date
of purchase, when this major
appliance is installed, operated
and maintained according to
instructions attached to or
furnished with the product,
Whirlpool Corporation or
Whirlpool Canada LP (hereafter
“Whirlpool”) will pay for Factory
Specified Replacement Parts and
repair labor to correct defects in
materials or workmanship that
existed when this major appliance
was purchased, or at its sole
discretion replace the product. In
the event of product replacement,
your appliance will be warranted
for the remaining term of the
original unit’s warranty period.
YOUR SOLE AND EXCLUSIVE
REMEDY UNDER THIS LIMITED
WARRANTY SHALL BE PRODUCT
REPAIR AS PROVIDED HEREIN.
Service must be provided by a
Whirlpool designated service
company. This limited warranty
is valid only in the United States
or Canada and applies only when
the major appliance is used in the
country in which it was purchased.
This limited warranty is effective
from the date of original consumer
purchase. Proof of original
purchase date is required to obtain
service under this limited warranty.
1. Commercial, non-residential, multiple-family use, or use inconsistent with published user,
operator or installation instructions.
2. In-home instruction on how to use your product.
3. Service to correct improper product maintenance or installation, installation not in accordance
with electrical or plumbing codes or correction of household electrical or plumbing (i.e. house
wiring, fuses or water inlet hoses).
4. Consumable parts (i.e. light bulbs, batteries, air or water filters, preservation solutions, etc.).
5. Defects or damage caused by the use of non-genuine Whirlpool parts or accessories.
6. Conversion of products from natural gas or L.P. gas.
7. Damage from accident, misuse, abuse, fire, floods, acts of God or use with products not
approved by Whirlpool.
8. Repairs to parts or systems to correct product damage or defects caused by unauthorized
service, alteration or modification of the appliance.
9. Cosmetic damage including scratches, dents, chips, and other damage to the appliance finishes
unless such damage results from defects in materials and workmanship and is reported to
Whirlpool within 30 days.
10. Discoloration, rust or oxidation of surfaces resulting from caustic or corrosive environments
including but not limited to high salt concentrations, high moisture or humidity or exposure to
chemicals.
11. Food or medicine loss due to product failure.
12. Pick-up or delivery. This product is intended for in-home repair.
13. Travel or transportation expenses for service in remote locations where an authorized Whirlpool
servicer is not available.
14. Removal or reinstallation of inaccessible appliances or built-in fixtures (i.e. trim, decorative
panels, flooring, cabinetry, islands, countertops, drywall, etc.) that interfere with servicing,
removal or replacement of the product.
15. Service or parts for appliances with original model/serial numbers removed, altered or not easily
determined.
The cost of repair or replacement under these excluded circumstances shall be borne by the
customer.
DISCLAIMER OF IMPLIED WARRANTIES
IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR A
PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW. Some states and provinces do not
allow limitations on the duration of implied warranties of merchantability or fitness, so this limitation may not apply to you. This warranty gives
you specific legal rights, and you also may have other rights that vary from state to state or province to province.
DISCLAIMER OF REPRESENTATIONS OUTSIDE OF WARRANTY
Whirlpool makes no representations about the quality, durability, or need for service or repair of this major appliance other than the
representations contained in this warranty. If you want a longer or more comprehensive warranty than the limited warranty that comes with
this major appliance, you should ask Whirlpool or your retailer about buying an extended warranty.
LIMITATION OF REMEDIES; EXCLUSION OF INCIDENTAL AND CONSEQUENTIAL DAMAGES
YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR AS PROVIDED HEREIN.
WHIRLPOOL SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states and provinces do not allow the
exclusion or limitation of incidental or consequential damages, so these limitations and exclusions may not apply to you. This warranty gives
you specific legal rights, and you also may have other rights that vary from state to state or province to province.
www.whirlpool.com/product_help
15
SÉCURITÉ DE LA HOTTE DE CUISINIÈRE
Risque possible de décès ou de blessure grave si vous ne
suivez pas immédiatement les instructions.
Risque possible de décès ou de blessure grave si vous
ne suivez pas les instructions.
Tous les messages de sécurité vous diront quel est le danger potentiel et vous disent comment réduire le risque de blessure et
ce qui peut se produire en cas de non-respect des instructions.
Votre sécurité et celle des autres est très importante.
Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de
toujours lire tous les messages de sécurité et de vous y conformer.
AVERTISSEMENT
DANGER
Voici le symbole d’alerte de sécurité.
Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous
et à d’autres.
Tous les messages de sécurité suivront le symbole d’alerte de sécurité et le mot “DANGER” ou
“AVERTISSEMENT”. Ces mots signifient :
Avertissements de la proposition 65 de l'État de Californie :
AVERTISSEMENT : Ce produit contient au moins un produit chimique connu par l’État de Californie pour être à l’origine de
cancers.
AVERTISSEMENT : Ce produit contient au moins un produit chimique connu par l’État de Californie pour être à l’origine de
malformations et autres déficiences de naissance.
16
IMPORTANTES INSTRUCTIONS DE SÉCURITÉ
LIRE ET CONSERVER CES INSTRUCTIONS
AVERTISSEMENT : POUR RÉDUIRE LE RISQUE
D'INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES
CORPORELS, RESPECTER LES INSTRUCTIONS
SUIVANTES :
Utiliser cet appareil uniquement dans les applications
envisagées par le fabricant. Pour toute question, contacter
le fabricant.
Avant d'entreprendre un travail d'entretien ou de nettoyage,
interrompre l'alimentation de la hotte au niveau du tableau
de disjoncteurs, et verrouiller le tableau de disjoncteurs
pour empêcher tout rétablissement accidentel de
l'alimentation du circuit. Lorsqu'il n'est pas possible de
verrouiller le tableau de disjoncteurs, placer sur le tableau
de disjoncteurs une étiquette d'avertissement proéminente
interdisant le rétablissement de l'alimentation.
Tout travail d'installation ou câblage électrique doit être
réalisé par une personne qualifiée, dans le respect des
prescriptions de tous les codes et normes applicables, y
compris les codes du bâtiment et de protection contre les
incendies.
Ne pas faire fonctionner un ventilateur dont le cordon ou la
fiche est endommagé(e). Jeter le ventilateur ou le retourner
à un centre de service agréé pour examen et/ou réparation.
Une source d'air de débit suffisant est nécessaire pour le
fonctionnement correct de tout appareil à gaz (combustion
et évacuation des gaz à combustion par la cheminée), pour
qu'il n'y ait pas de reflux des gaz de combustion. Respecter
les directives du fabricant de l'équipement de chauffage et
les prescriptions des normes de sécurité - comme celles
publiées par la National Fire Protection Association (NFPA)
et l'American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), et les prescriptions des
autorités réglementaires locales.
Lors des opérations de découpage et de perçage dans un
mur ou un plafond, ne pas endommager les câblages
électriques et les canalisations qui peuvent s’y trouver.
Les ventilateurs d'évacuation doivent toujours décharger
l'air à l'extérieur.
MISE EN GARDE : Cet appareil est conçu uniquement
pour la ventilation générale. Ne pas l'utiliser pour l'extraction
de matières ou vapeurs dangereuses ou explosives.
MISE EN GARDE :
Pour minimiser le risque d'incendie
et évacuer adéquatement les gaz, veiller à acheminer l'air
aspiré par un conduit jusqu'à l'extérieur - ne pas décharger
l'air aspiré dans un espace vide du bâtiment comme une
cavité murale, un plafond, un grenier, un vide sanitaire ou
un garage.
AVERTISSEMENT :
POUR RÉDUIRE LE RISQUE
D'INCENDIE, UTILISER UNIQUEMENT DES CONDUITS
MÉTALLIQUES.
AVERTISSEMENT : POUR MINIMISER LE RISQUE
D'UN FEU DE GRAISSE SUR LA CUISINIÈRE :
Ne jamais laisser un élément de surface fonctionner à
puissance de chauffage maximale sans surveillance. Un
renversement/débordement de matière graisseuse pourrait
provoquer une inflammation et la génération de fumée.
Utiliser une puissance de chauffage moyenne ou basse
pour le chauffage d'huile.
Veiller à toujours faire fonctionner le ventilateur de la hotte
lors de la cuisson avec une puissance de chauffage élevée
ou lors de la cuisson d'un mets à flamber (à savoir crêpes
Suzette, cerise jubilée, steak au poivre flambé).
Nettoyer fréquemment les ventilateurs d'extraction. Veiller à
ne pas laisser la graisse s'accumuler sur les surfaces du
ventilateur ou des filtres.
Utiliser toujours un ustensile de taille appropriée. Utiliser
toujours un ustensile adapté à la taille de l'élément
chauffant.
AVERTISSEMENT : POUR RÉDUIRE LE RISQUE DE
DOMMAGES CORPORELS APRÈS LE DÉCLENCHEMENT
D'UN FEU DE GRAISSE SUR LA CUISINIÈRE, APPLIQUER
LES RECOMMANDATIONS SUIVANTES :
a
Placer sur le récipient un couvercle bien ajusté, une tôle à
biscuits ou un plateau métallique POUR ÉTOUFFER LES
FLAMMES, puis éteindre le brûleur. VEILLER À ÉVITER
LES BRÛLURES. Si les flammes ne s'éteignent pas
immédiatement, ÉVACUER LA PIÈCE ET APPELER LES
POMPIERS.
NE JAMAIS PRENDRE EN MAIN UN RÉCIPIENT
ENFLAMMÉ - vous risquez de vous brûler.
NE PAS UTILISER D'EAU, ni un torchon humide - ceci
pourrait provoquer une explosion de vapeur brûlante.
Utiliser un extincteur SEULEMENT si :
– Il s'agit d'un extincteur de classe ABC, dont on connaît le
fonctionnement.
– Il s'agit d'un petit feu encore limité à l'endroit où il s'est
déclaré.
– Les pompiers ont été contactés.
– Il est possible de garder le dos orienté vers une sortie
pendant l'opération de lutte contre le feu.
a
Recommandations tirées des conseils de sécurité en cas
d'incendie de cuisine publiés par la NFPA.
AVERTISSEMENT : Pour réduire le risque d'incendie
ou de choc électrique, ne pas utiliser ce ventilateur avec un
quelconque dispositif de réglage de la vitesse à semi-
conducteurs.
17
EXIGENCES D’INSTALLATION
Outillage et pièces
Rassembler les outils et pièces nécessaires avant
d’entreprendre l’installation. Lire et observer les instructions
fournies avec chacun des outils de la liste ci-dessous.
Outils nécessaires
Pièces fournies
Retirer les pièces de l’emballage. Vérifier que toutes
les pièces sont présentes.
Pièces nécessaires
Pour installations avec conduit
d’évacuation circulaire de 7" (17,8 cm)
Accessoires en option
* Pour des renseignements sur la commande, voir la section
“Assistance ou service”.
Exigences d’emplacement
IMPORTANT : Observer les dispositions de tous les codes
et règlements en vigueur.
C’est à l’installateur qu’incombe la responsabilité
de respecter les distances de séparation spécifiées
sur la plaque signalétique. La plaque signalétique est
située à l’intérieur de la hotte, sur la paroi de gauche.
Installer la hotte de cuisinière à distance de toute zone
exposée à des courants d’air, comme fenêtres, portes
et bouches de chauffage à fort débit.
Respecter les dimensions indiquées pour les ouvertures
à découper dans les meubles. Ces dimensions tiennent
compte des valeurs minimales des dégagements de
séparation. Avant d’effectuer des découpages, consulter
les instructions d’installation fournies par le fabricant
de la table de cuisson/cuisinière.
Il est recommandé d’utiliser cette hotte avec une table
de cuisson dont la puissance totale ne dépasse pas
40 000 BTU.
Une prise de courant électrique reliée à la terre est
nécessaire. Voir la section “Spécifications électriques”.
Assurer l’étanchéité au niveau de chaque ouverture
découpée dans le plafond ou le mur pour l’installation
de la hotte de cuisinière.
Ces hottes de cuisinière ont été configurées à l’usine pour
une installation avec décharge à l’extérieur. Les modèles
pouvant être installés dans une configuration sans décharge
à l’extérieur (recyclage) nécessitent des filtres à charbon.
Voir la section “Assistance ou service” pour connaître le
processus de commande des filtres à charbon.
Installation dans une résidence mobile
L’installation de cette hotte doit satisfaire aux exigences
de la norme Manufactured Home Construction Safety
Standards, Titre 24 CFR, partie 328 (anciennement Federal
Standard for Mobile Home Construction and Safety, titre 24,
HUD, partie 280); lorsque cette norme n’est pas applicable,
l’installation doit satisfaire aux critères de la plus récente
édition de la norme Manufactured Home Installation 1982
(Manufactured Home Sites, Communities and Setups) ANSI
A225.1/NFPA 501A ou des codes et règlements locaux.
Pistolet à calfeutrage et composé
de calfeutrage résistant aux
intempéries
Scie sauteuse ou scie à guichet
Tournevis à
lame plate
Perceuse avec
forets de ¹⁄₈"
(3 mm), ¹⁄₂"
(13 mm) et
1 ¹⁄₄" (3 cm)
Pince à dénuder
Tournevis
Phillips n˚ 2
Cisaille de ferblantier
Crayon
Vis à tête bombée
n˚ 8-18 x 5/8"
(4,2 x 16 mm)
Vis à tête plate
n˚ 8-18 x 1"
(4,2 x 25 mm)
Chevilles
d'ancrage
Brides de
montage
Plaque de montage de conduit
circulaire de 7" (17,8 cm)
Pièce numéro W10388168*
Connecteurs
de fils
homologués UL/CSA
Lampe de
120 V,
75 watts
maximum,
à culot E26
Circuit d'évacuation métallique
circulaire de 7" (17,8 cm)
avec bouche de décharge à
travers le mur ou à travers le toit
Clapet anti-reflux
circulaire de 7" (17,8 cm)
Pièce numéro
W10355451*
Brides de conduit
selon le besoin
Ensemble du cordon
d'alimentation
Pièce numéro
W10355452*
Nettoyant et poli pour
acier inoxydable
Pièce numéro 31462A*
18
Dimensions du produit
Distances de dégagement à respecter
Circuit d’évacuation
Méthodes d’évacuation
REMARQUES :
L’emploi d’un conduit flexible est déconseillé. Un conduit
flexible peut causer une rétro-pression et des turbulences
de l’air, ce qui réduit considérablement la performance.
Le circuit d’évacuation est facultatif pour ce modèle.
La sortie à l’extérieur du circuit d’évacuation peut se faire
à travers le toit ou à travers un mur. Utiliser un conduit
d’évacuation circulaire de 7" (17,8 cm) ou plus large, d’une
longueur maximale de 50 pi (15,2 m) pour le circuit d’évacuation.
Évacuation par le dessus Évacuation par le mur
A
B
A
B
A. Conduit circulaire
de 7" (17,8 cm) pour
évacuation à travers le toit
(à acheter séparément)
B. Bouche de décharge
sur toit avec clapet
(à acheter séparément)
A. Conduit rond de 7" (17,8 cm)
avec sortie par le dessus
et décharge à travers le mur
(à acheter séparément)
B. Bouche de décharge
à travers le mur avec clapet
(à acheter séparément)
Installations dans les régions au climat froid
On doit installer un clapet anti-retour supplémentaire à
l’arrière pour minimiser le reflux d’air froid et incorporer
un élément d’isolation thermique pour minimiser la conduction
de chaleur par l’intermédiaire du conduit d’évacuation,
de l’intérieur de la maison à l’extérieur. Le clapet anti-retour
doit être placé du côté air froid de la résistance thermique.
L’élément d’isolation thermique doit être aussi proche que
possible de l’endroit où le circuit d’évacuation s’introduit
dans la partie chauffée de la maison.
Air d’appoint
Les codes locaux en bâtiment peuvent imposer l’emploi d’un
circuit de renouvellement de l’air/introduction d’air d’appoint,
lors de l’utilisation d’un circuit d’aspiration de débit supérieur
à une valeur spécifiée en pieds cubes par minute. Le débit
spécifié en pieds cubes par minute varie d’une juridiction
à l’autre. Consulter un professionnel des installations de
chauffage ventilation/climatisation au sujet des exigences
spécifiques applicables dans la juridiction locale.
1"
(2,5 cm)
4¹⁵⁄₁₆"
(12,5 cm)
6⁹⁄₁₆" (16,7 cm)
29¹⁵⁄₁₆" (76,0 cm)
18⁵⁄₈"
(47,3 cm)
1¹⁄₂"
(3,8 cm)
9"
(22,9 cm)
2"
(5,1 cm)
1"
(2,5 cm)
B
A
C
D
E
A. 24" (61 cm) de distance minimale à partir
de la surface de cuisson électrique
24" (61 cm) de distance minimale à partir
de la surface de cuisson au gaz
30" (76,2 cm) de distance maximale suggérée
au-dessus de la surface de cuisson
B. 18" (45,7 cm) de dégagement minimal entre
le placard supérieur et le plan de travail
C. 30" (76,2 cm) de largeur minimale d’ouverture du placard
D. 12" (30,5 cm) de profondeur de placard
E. 36" (91,4 cm) de hauteur du placard du bas
19
Exigences concernant l’évacuation
Le système doit décharger l’air à l’extérieur.
Ne pas terminer le circuit d’évacuation dans un grenier
ou dans un autre espace clos.
Ne pas utiliser une bouche de décharge murale
de 4" (10,2 cm) normalement utilisée pour un
équipement de buanderie.
Utiliser un conduit d’évacuation métallique circulaire de
7" (17,8 cm). Un conduit en métal rigide est recommandé.
Ne pas utiliser de conduit de plastique ou en aluminium.
La longueur du circuit d’évacuation et le nombre
de coudes doivent être réduits au minimum pour
des performances optimales.
Pour un fonctionnement efficace et silencieux :
Ne pas utiliser plus de trois coudes à 90°.
Veiller à ce qu’il y ait une section droite de conduit
d’un minimum de 24" (61 cm) entre les coudes si
l’on doit utiliser plus d’un coude.
Ne pas installer 2 coudes successifs.
Utiliser des brides ou du ruban adhésif pour conduit
pour assurer l’étanchéité de chaque jointure du circuit
d’évacuation.
Le circuit d’évacuation doit comporter un clapet
anti-reflux. Si la bouche de décharge murale ou
par le toit comporte un clapet, ne pas utiliser
le clapet fourni avec la hotte de cuisinière.
À l’aide d’un produit de calfeutrage, assurer
l’étanchéité autour de la bouche de décharge
à l’extérieur (à travers le mur ou le toit).
Calcul de la longueur du circuit d’évacuation
Pour calculer la longueur effective du circuit d’évacuation
nécessaire, additionner les longueurs équivalentes (en pieds
ou mètres) de tous les composants utilisés dans le circuit.
Circuit d’évacuation
Composant
Coude à 45° 2,5 pi (0,8 m)
Coude à 90° 5 pi (1,5 m)
Bouche de décharge
murale de 7" (17,8 cm)
0 pi (0 m)
Exemple de circuit d’évacuation
1 coude à 90° = 5 pi (1,5 m)
1 bouche de décharge murale = 0 pi (0 m)
Section droite de 8 pi (2,4 m) = 8 pi (2,4 m)
Longueur totale = 13 pi (3,9 m)
Longueur maximale recommandée
Circuit d’évacuation avec conduits
circulaires de 7" (17,8 cm)
= 50 pi (15,2 m)
Spécifications électriques
Observer les dispositions de tous les codes
et règlements en vigueur.
S’assurer que l’installation électrique est correcte et
qu’elle satisfait aux exigences de la plus récente édition
de la norme National Electrical Code, ANSI/NFPA 70
ou de la norme CSA C22. 1-94, Code canadien de
l’électricité, partie 1 et C22.2 No. 0-M91 (dernière édition),
et de tous les codes et règlements en vigueur.
Si les codes le permettent et si l’on utilise un conducteur
distinct de liaison à la terre, il est recommandé qu’un
électricien qualifié vérifie la qualité de la liaison à la terre.
Pour obtenir un exemplaire des normes des codes
ci-dessus, contacter :
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
L’appareil doit être alimenté par un circuit de 120 V,
CA seulement, 60 Hz, 15 ampères, protégé par fusible.
Si le domicile possède un câblage en aluminium,
suivre la procédure ci-dessous :
1. Raccorder une section de câble en cuivre massif
aux conducteurs en queue de cochon.
2. Connecter le câblage en aluminium à la section
ajoutée de câblage en cuivre en utilisant des
connecteurs et/ou des outils spécialement conçus
et homologués UL pour fixer le cuivre à l’aluminium.
Suivre la procédure recommandée par le fabricant de
connecteurs électriques. Les raccordements aluminium/
cuivre doivent satisfaire aux prescriptions des codes
locaux et de l’industrie, et être conformes aux pratiques
de câblage reconnues.
Le calibre des conducteurs et les connexions doivent
être compatibles avec les caractéristiques électriques
de l’appareil spécifiées sur la plaque signalétique. La
plaque signalétique de l’appareil est située à l’intérieur
de la hotte, sur la paroi de gauche.
Le calibre des conducteurs doit être conforme aux
exigences du National Electrical Code, de la plus récente
édition de la norme ANSI/NFPA 70 ou des normes CSA
C22. 1-94, Code canadien de l’électricité, partie 1 et
C22.2 No. 0-M91 (édition la plus récente) et de tous
les codes et règlements en vigueur.
décharge
murale
2 pi (0,6 m)
6 pi (1,8 m)
20
INSTRUCTIONS D’INSTALLATION
REMARQUES :
Selon le modèle, déterminer la méthode d’évacuation
à utiliser : à travers le toit ou à travers le mur.
Il est recommandé que l’installation du circuit
d’évacuation soit réalisée avant celle de la
hotte. Voir “Circuit d’évacuation” dans la section
“Exigences d’installation” en cas de besoin.
Avant d’exécuter les découpages, vérifier qu’il existe
un dégagement suffisant dans le plafond ou le mur
pour le conduit d’évacuation.
1. Déconnecter la source
de courant électrique
2. Marquage de l’emplacement
des trous
Aligner le bord extérieur des brides de montage
avec les bords extérieurs du placard supérieur.
IMPORTANT : Les brides de montage doivent être
en contact avec le placard supérieur.
Marquer les trous supérieurs des brides avec un crayon.
3. Installation des brides
À l’aide d’un tournevis Phillips n° 2, installer
les chevilles d’ancrage.
À l’aide des vis à tête plate n° 8-18 x 1" (4,2 x 25 mm)
Phillips n° 2, installer les brides de montage en utilisant
les trous supérieurs.
REMARQUE : Pour les installations sur une surface autre
qu’un panneau de gypse, il est recommandé de faire appel
à du personnel qualifié pour déterminer la méthode d’ancrage.
4. Préparation de la hotte
Placer la hotte en appui sur la face arrière,
sur une surface couverte.
À l’aide d’un tournevis Phillips n° 2, retirer la plaque
de montage du conduit rond de 7" (17,8 cm) attachée
avec des vis de 3,5 x 9,5 mm.
À l’aide d’un tournevis Phillips n° 2, retirer le couvercle
du boîtier de raccordement.
A l’aide d’un tournevis à lame plate, retirer l’opercule
pour le passage de l’alimentation électrique approprié.
AVERTISSEMENT
Risque de choc électrique
Déconnecter la source de courant électrique avant
l'entretien.
Replacer pièces et panneaux avant de faire la remise
en marche.
Le non-respect de ces instructions peut causer
un décès ou un choc électrique.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

KitchenAid 30" Range with the FIT System Le manuel du propriétaire

Catégorie
Hottes
Taper
Le manuel du propriétaire
Ce manuel convient également à