Extron NBP 200 Manuel utilisateur

Taper
Manuel utilisateur

Ce manuel convient également à

1
IMPORTANT:
Go to www.extron.com for the complete
user guide,
installation instructions,
and
specifications bef
ore connecting the
pr
oduct to the po
wer source.
Network Button Panel — US Gang Series •
Setup Guide
Overview
The Extron NBP Network Button Panels are fully customizable AV system control interfaces for use with Extron IPCPPro Series
and IPLPro Series Control Processors, and with Extron meeting space collaboration system products. The NBPs in this guide
fit a standard US two-gang or three-gang electrical junction box or mud ring. They have one white and one black faceplate for
each NBP, and a two- or three-gang mud ring. Each NBP button panel has a single LAN port, which supports both power and
communications between the control processor and button panels.
Use Extron Toolbelt software to discover and manage NBP button panels and assign each one a unique IP address. Then use
Extron GlobalConfigurator
®
(GC) Plus and Professional software, or Global Scripter
®
programming to configure the control
system, including the buttons on NBPs. Once configured, the AV system can be controlled from any of the NBPs.
This guide provides basic instructions for an experienced installer to install an NBP100 or NBP200 button panel. For more
about the NBPs, see the Network Button Panels User Guide, available on www.extron.com. For details on configuration, see the
software help files.
Front Panel Features
E
ON OFF
MEDIA
PLAYER
LAPTOP
PC
VIDEO
MUTE
HDMI 1
HDMI 2
WIRELESS
Extron
ON
PC
VIDEO
MUTE
LAPTOP
OFF
ON OFF
MEDIA
PLAYER
LAPTOP
PC
VIDEO
MUTE
HDMI 1 HDMI 2
WIRELESS
RESET
q
RESET
ON
PC
VIDEO
MUTE
LAPTOP
OFF
q
MAC: 00-05-A6-XX-XX-XX
S/N:
XXXXXXX
E
XXXXXX
00-05-A6-XX-XX-XX
MAC: 00-05-A6-XX-XX-XX
S/N:
XXXXXXX
E
XXXXXX
00-05-A6-XX-XX-XX
BBBB
C
D
C
D
C
D
C
D
C
D
C
D
C
D
C
D
B
BBB
NBP 100 Front Panel with Faceplate
NBP 100 Front Panel without Faceplate
AAAA
NBP 200 Front Panel with Faceplate
NBP 200 Front Panel without Faceplate
AAAA
Faceplate
Faceplate
EEEE
Mounting Holes (x4)
Mounting Holes (x6)MAC Address
EEEE
Figure 1. Front Panels With and Without Faceplates
A
Function buttons — Configure these buttons to light and function as desired.
B
Power buttons — These buttons are usually used to control the power to the display device. The On button has a nub that
can be felt with finger tips.
C
Volume knob — Configure the volume knob to increment or decrement audio volume.
D
Volume LEDs — Volume LEDs light to act as a meter to indicate the volume level.
C
Communications LED — This LED (present on certain
models only) indicates the configuration and connection status
of the NBP (see figure 1 on page 1).
Unlit — Normal operation (the NBP is configured and
connected to an IPCPPro control processor).
Blinking red — The NBP has been configured but is not
connected to an IPCPPro control processor.
Lit steadily — The NBP has not been configured.
2
Network Button Panel — US Gang Series • Setup Guide (Continued)
E
Reset button and LED — Pressing this recessed button (see figure 1 on the previous page) causes various product settings
to be reset to the factory defaults (see Reset Modes: a Brief Summary on page7). The LED is normally off except during
resets and immediately after boot-up.
All the function buttons, power buttons, and volume knob must be configured or programmed to carry out their functions. The
buttons are backlit by LEDs.
Buttons that are configured or programmed but are inactive are dimly lit.
Buttons that are not configured are dimly lit.
The NBP buzzes or chirps each time a button is pressed.
Rear Panel Features
LAN (Ethernet) and PoE connector and LEDs — Connect the unit to a network via this connector for control and Power over
Ethernet. Use the following diagrams as a guide.
NBP 200
Rear Panel
e
YYW W-N -L- M
e
YYW W-N -L- M
e
YYW W-N -L- M
e
YYW W-N -L- M
e
NBP 100
Rear Panel
e
e
e
YYW W-N -L- M
e
e
Side View
Side View
Grounding
Screw
LAN/PoE
(Ethernet)
connector
and LEDs
Figure 2. Rear Panel Features
LAN/PoE
RJ-45
Connector
NBP Rear Panel
LAN/PoE (Ethernet and
Power Over Ethernet)
Ethernet
NOTE:
MAC address information
(00-05-A6-XX-XX-XX)
is located on the front panel,
behind the faceplate.
PC
Link LED: Lights
green to indicate a
network connection.
Activity LED:
Blinks
amber to
indicate data
is being sent
or received.
TCP/IP
Network
Extron
IPCP Pro
Control
Processor
Connect to an Ethernet network.
This port must be congured.
Default protocol:
• NBP address: 192.168.254.253
• Gateway IP address: 0.0.0.0
• Subnet mask: 255.255.255.0
• DNS address: 127.0.0.1
• DHCP: off
• Link speed and duplex level: autodetected
• Data rates: 10/100Base-T
Power over Ethernet (PoE):
The NBP receives power at this port.
Default login credentials:
• Username: admin
• Initial password: unit serial number
• Password after a “Reset to Factory
Defaults”: extron
MAC: 00-05-A6-XX-XX-XX
S/N: XXXXXXX EXXXXXX
00-05-A6-XX-XX-XX
MAC: 00-05-A6-XX-XX-XX
S/N: XXXXXXX EXXXXXX
MAC
Address
Figure 3. LAN/PoE Port Details
NOTE: See the grounding instructions on page5.
ATTENTION:
Power over Ethernet (PoE) is
intended for indoor use only. It is to
be connected only to networks or
circuits that are not routed to the
outside plant or building.
L’alimentation via Ethernet (PoE) est
destinée à une utilisation en intérieur
uniquement. Elle doit être connectée
seulement à des réseaux ou des
circuits qui ne sont pas routés au
réseau ou au bâtiment extérieur.
IMPORTANT NOTES:
The factory configured password
for this device has been set to the
device serial number. Passwords are
case sensitive. Performing a Reset to
Factory Defaults (see Reset Modes:
a Brief Summary on page7)
sets the password to extron.
DHCP is off by default.
Rev. C: Added notes about the factory-set
passwords being the serial number and
about DHCP being off by default.
3
Installation
Step 1: Get Ready
Use the following check list to prepare for the installation.
Download and install the latest versions of the software, firmware, and device drivers needed to configure or program the control
processor or HCR receiver to interact with the NBPs and control the connected AV products. See the IPCPPro Series User Guide,
IPLPro Series User Guide, or HC400 Series User Guide (available at www.extron.com) for details on software and drivers.
Obtain network information for the unit from the network administrator. You need the following details for each IPLinkPro
device, including the IPCPPro and each NBP:
DHCP setting (on or off) Subnet mask User name
Device (NBP) IP address Gateway IP address Passwords
NOTE: If DHCP is on, you do not need the IP addresses and subnet mask.
Write down the MAC address of each IPLinkPro device (such as the NBP) to be used.
Obtain model names and setup information for the AV devices to be controlled in the system.
Each NBP button panel comes with a factory-installed Secure Sockets Layer (SSL) security certificate. If you intend to install
a different SSL certificate, contact your IT department to obtain the certificate or for instructions on how to obtain one. See
“Secure Sockets Layer (SSL) Certificates” in the Network Button Panels User Guide for requirements and guidelines regarding
SSL certificates.
Step 2: Prepare the Installation Site
ATTENTION:
Installation and service must be performed by authorized personnel only.
L’installation et l’entretien doivent être effectués par le personnel autorisé uniquement.
Extron recommends installing the NBP into a grounded, UL Listed electrical junction box.
Extron recommande d’installer le NBP dans une boîte de dérivation électrique mis à la terre, certifiée UL.
If the NBP will be installed into fine furniture, it is best to hire a licenced, bonded craftsperson to cut the access hole and
perform the physical installation so the surface will not be damaged.
S’il est prévu d’installer le NBP dans du beau mobilier, il est préférable de faire appel à un artisan autorisé et qualifié pour
couper le trou d’accès et réaliser l’installation de telle façon que la surface ne soit pas endommagée.
Follow all national and local building and electrical codes that apply to the installation site.
Respectez tous les codes électriques et du bâtiment, nationaux et locaux, qui s’appliquent au site de l’installation.
For the installation to meet UL requirements and to comply with National Electrical Code (NEC), the NBP must be installed
in a ULListed junction box. The end user or installer must furnish the junction box. It is not included with the unit.
Pour que l’installation respecte les exigences UL et soit conforme au National Electrical Code (NEC) américain, le NBP
doit être installé dans une boîte de dérivation certifiée UL. Il incombe à l’utilisateur final ou à l’installateur de fournir la
boîte de dérivation. Cet équipement n’est pas inclus avec l’unité.
Americans with Disabilities Act (ADA) compliance
When planning where to install the NBP button panels, you may need to consider factors affecting
accessibility of the button panels such as height from the floor, distance from obstructions, and
how far a user must reach to press the buttons. For guidelines, see sections
307 (“Protruding Objects”) and 308 (“Reach Ranges”) of the
2010 ADA Standards for Accessible Design available at
http://www.ada.gov/regs2010/2010ADAStandards/2010ADAStandards.pdf.
Site preparation
Each unit ships with a mud ring. Optional
ULListed in-wall junction boxes, external wall
boxes (EWBs), and surface or tabletop mounting
boxes are available for use with the button panels.
Read any installation instructions and UL
guidelines that come with the mounting devices, then follow the instructions to
install the box or mud ring in the opening at the installation site.
When you run cables to the mounting location, leave enough slack for device
installation. Secure the cables with a clamp for strain relief and so they do not slip
back down into the wall or furniture.
Rev. B: Added note.
Rev. B: Changed French text in the
second Attention
Rev. B: Changed the note to an
Attention & added French text,
per Homi As requirement for the
HC products..
Model US Gang Size
NBP 100 2
NBP 200 3
Mud Ring
Wall
4
Network Button Panel — US Gang Series • Setup Guide (Continued)
Step 3: Change a Faceplate, Button Labels, or Knob (Optional)
The faceplate, button labels, and knob can easily be changed at any time. Some button labels ship with the unit. You can create
and print your own customized labels using Extron Button Label Generator software.
Replacing a faceplate
To replace a faceplate:
1. Remove the faceplate by holding the body of the unit with one hand, gripping the sides of the faceplate with the other hand,
and pulling the faceplate away from the unit.
2. Align the openings of the new faceplate with the buttons and knob and with the LEDs, and place the faceplate against the
unit. The magnetic catches fasten the faceplate onto the unit.
Replacing button labels
To change a button label:
1. Remove the faceplate as described in step 1 of “Replacing a faceplate,” above.
2. For each button label to be replaced, gently separate the button lens cap from its
white diffuser. To to this, insert the end of the provided Extron removal (pry) tool
removal tool into the corner notch and gently twist the tool (see
1
in the
image at right).
3. Remove the label insert from the translucent button cap.
TIP: If the insert does not come out easily, use a piece of
sticky tape to pull it out of the button cap.
4. Select one of the button labels from the printed label sheets
included with the unit. Remove the label from its backing and
remove the clear, protective film from the front of the label.
5. Insert the button label into the button cap (see
2
at right).
Check for correct label orientation.
6. Align the cap with the white diffuser and the panel opening,
and press the clear cap into place on the button.
7. Reattach the faceplate to the unit (see step 2 in “Replacing a
faceplate”).
Changing a knob
To change a knob:
1. Remove the faceplate as described in step 1 of
“Replacing a faceplate.”
2. Firmly grasp the knob and pull it away from the NBP.
3. Align the ridge inside the new knob with the channel on
the knob control and allow the magnet in the knob to
snap into place (see
3
at right).
4. Reattach the faceplate to the unit (see step 2 in
“Replacing a faceplate” and see
4
at right).
TEXT
Separate the
two-piece button
her
e at the corner.
Dif
fuser
Base
Insert
button label.
Button
Lens Cap
Removal
(Pry) Tool
1
2
RESET
e
ON OFF
MAC: 00-05-A6-XX-XX-XX
S/N: ####### E######
00-05-A6-XX-XX-XX
Extron
33
4
4
5
Step 4: Cable All Devices
1. If the button panel is not mounted to a grounded metal
junction box or a grounded metal equipment rack, Extron
recommends connecting the unit to an earth ground to
protect the unit from electrostatic discharge.
To ground the unit:
a. Securely terminate a grounding cable with a ring terminal.
b. Remove the grounding screw in the lower left corner
of the rear panel, insert the grounding cable, replace
and securely fasten the screw (see figure 4 at right).
Do not over-tighten the screw. Maximum torque is
2inch-pounds (0.2 Newton-meter).
c. Connect the other end of the grounding cable to an
earth ground.
2. Connect the NBP to the network (see Rear Panel Features
on page2), and cable devices to the control processor or
HCR receiver (see the user guide for the appropriate device).
3. Connect power cords and power on the control processor
or receiver and other devices.
Step 5: Set Up the NBP for Network
Communication
1. Ensure that the PC that you will use for setup and the
NBP button panel are connected to the same Ethernet
subnetwork.
2. Start Toolbelt and use it to set the DHCP status or to
set the IP address, subnet, gateway IP address, DHCP
status, and related settings. Use the flowchart at right
as a guide to setting up the unit for network use.
NOTE: If using a host name instead of an IP
address, the user must enter a qualified host
name (Username.HostName.Domain).
For example: somename.somedomain.com.
Step 6: Configure the System
Use Global Configurator (GCPlus or GCProfessional) to
configure the IPCPPro control processor, IPLPro control processor, or HCR receiver. Alternatively, use Global Scripter to program
the control processor. That configuration sets the control and monitoring behavior for all the AV devices and control accessories
(such as the NBP button panels) in the system. An outline of the main configuration and programming steps is included in the
user guide for the control device.
NOTE: See the Toolbelt Help File, Global Configurator Help File, and Global Scripter Help File as needed for step-by-step
instructions and detailed information. The help file for GC includes an introduction to the software, and how to start a
project and configuration.
When configuration or programming is completed, save the project or program script, then build and upload the system
configuration to the control processor or receiver.
Step 7: Test and Troubleshoot
1. Test the system. See the IPCPPro Series User Guide, IPLPro Series User Guide, or HC400 Series User Guide for an outline
of the system testing and troubleshooting procedure.
2. Make adjustments to wiring or configuration as needed. Remember that the rear panel port on the button panel is not
accessible after the NBP is mounted.
LAN
/
PoE
NBP 100 Rear Panel
Figure 4. Connecting a Grounding Wire to the NBP
Open the Toolbelt software.
Start Device Discovery.
Toolbelt displays a list of all Extron control devices
connected to the network.
Using the MAC address, locate the desired device
in the list and select it. Enter credentials, if needed.
Network Communication Setup
Connect the NBP and PC to the same network.
Apply power to all devices.
Use the Set IP feature in Toolbelt or
use the Toolbelt
Manage > Network Settings tab
feature either to enable DHCP or to enter the
IP address, subnet address, and gateway, then
congure other network settings as needed.
Figure 5. Network Setup
Rev. B: Added
“Enter credentials,
if needed” and
“enable DHCP or
to...” to the network
setup flowchart.
Rev. B: Deleted
reference to
“during project
recovery”
6
Network Button Panel — US Gang Series • Setup Guide (Continued)
Step 8: Complete the Physical Installation
Mount the unit to a wall or furniture (see “Mounting”, below).
Mounting
Mount the NBP as follows:
1. Insert the cabled NBP into the mud ring or junction box within the wall or furniture, aligning the mounting holes in the NBP
with those in the box or mud ring.
2. Secure the NBP to the junction box, wall or surface mounting box, or
mud ring as follows (see figures 6 and 7):
a. Insert the included screws through the mounting
holes at the top and bottom of the unit, through
the plastic spacer (if not using a mud ring),
and into the corresponding threaded holes in
the box or mud ring.
NOTE: If the unit is not installed in a
mud ring, you must install the plastic
spacer. The spacer positions the unit
to allow the magnetic faceplate to
attach properly and securely.
b. Using a Phillips screwdriver, lightly tighten
the screws until snug.
ATTENTION:
Do not overtighten the screws.
Veillez à ne pas trop serrer les vis.
e
ON OFF
MAC: 00-05-A6-XX-XX-XX
S/N: ####### E######
00-05-A6-XX-XX-XX
Extron
Wall
Faceplate
NBP 100
Plastic Spacer
Wall Box
3. Attach the wallplate to the NBP: align the faceplate openings with the buttons, knob, and LEDs, and place the faceplate
against the unit (see figures 6 and 7). The magnetic catches fasten the faceplate onto the front of the unit.
ON
MAC: 00-05-A6-XX-XX-XX
S/N: ####### E######
00-05-A6-XX-XX-XX
Extron
Wall
NBP 100
Mud Ring
Faceplate
Figure 6. Installing the NBP in a Mud Ring
Figure 7. Installing the NBP in a Junction Box
NOTE: Extron
recommends taking
precautions to
avoid electrostatic
discharge issues
during installation.
7
Reset Modes: a Brief Summary
The NBP Series button panels offer the following reset modes:
Use Factory Firmware: Press and hold the Reset button while applying power to the unit. Keep holding the button
down until the Reset LED blinks twice, or for 6 seconds, then release the button. The unit enters
factory firmware mode. Use this mode to revert to factory firmware in the event of a firmware
failure.
Do not continue to operate the unit using the factory rmware version. If you want to use the
factory default rmware version, you must upload that version again.
Toggle DHCP Client: Press the Reset button five times (consecutively). Release the button. Do not press the button
within 3seconds following the fifth press. Use this mode to enable or disable the DHCP client
for the LAN port.
The Reset LED blinks 6 times if the DHCP client is enabled.
The Reset LED blinks 3 times if the DHCP client is disabled.
NOTES:
By default DHCP is off and the unit uses a static IP address.
When you disable the DHCP client, the unit reverts to using the previously-set
static IP address.
Reset All IP Settings: Press and hold the Reset button for 6 seconds. After the Reset LED blinks twice, release and
momentarily press the Reset button. Use this mode to reset all network settings to factory
default values without affecting user-loaded files.
Reset to Factory Defaults: Press and hold the Reset button for 9 seconds. After the Reset LED blinks three times, release
and momentarily press the Reset button within 1 second. Use this mode to return the unit to
factory default settings.
For detailed information on each mode and its use, see the Network Button Panels User Guide at www.extron.com.
Resources
Obtaining Instructions, Information, and Assistance
If you have questions during installation and setup, call the ExtronS3 Sales & Technical Support Hotline or the ExtronS3
Control Systems Support Hotline (1.800.633.9877).
Locating Software and Firmware on the Extron Website
There are three main ways to find software and firmware within www.extron.com:
Via links from the web page for the specific product
Via the Download page (Click on the Download tab at the top of any page within the website.)
Via links from search results
NOTES:
For some software you have the option to click the Download Now button to begin downloading the software file. For
other software there is a link for contacting an Extron support representative who can provide you access to the latest
version.
To obtain Extron control product software, you must have an Extron Insider account. Extron provides training to our
customers on how to use the software. Access to the full features of Global Configurator Professional is available to
those who successfully complete Extron Control Professional Certification.
8
Network Button Panel — US Gang Series • Setup Guide (Continued)
© 2019 - Extron Electronics All rights reserved. www.extron.com
All trademarks mentioned are the property of their respective owners.
Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876
68-3267-51, Rev. B
09 19
Overall Configuration Procedure
Configure the IP settings of each NBP
and of the control processor or receiver.
See the network
communication
setup instructions
Create a new GC Professional or GC Plus project
and add the control processor or receiver to it.
Congure ports.
Add NBP button panels and congure the buttons.
Test the system, make adjustments,
nalize conguration.
Save the project.
Cable the NBPs and the control processor or HCR receiver,
then apply power.
Cable all devices.
Prepare the installation site.
Get ready.
Change buttons or faceplates, if desired
Mount the NBPs.
Create monitors, schedules, timers, macros,
and local variables.
Build and upload the conguration to
the controller or receiver.
If desired or required, install a new
security certicate (via Toolbelt).
Within Global Configurator
(GC Professional or
GC Plus mode):
Figure 8. Overall Configuration Steps
network
communication
setup instructions
on page 5.
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the
Extron Safety and Regulatory Compliance Guide on the Extron website.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Extron NBP 200 Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues