BEL RCM150/300 Guide d'installation

Taper
Guide d'installation
a
belfuse.com/power-solutions
INSTALLATION INSTRUCTION
RCM150/300 Series
150/300 W DC-DC Converters
F
ETY APPROVALS
OPERATION RANGE
Refer to product rating label for input and output ratings.
INSTALLATION
Connection to the system shall only be effected with cables with suitable wire section or mating connectors (option K).
The auxiliary connector shall be connected via the suitable female connector.
Other installation methods may not meet the safety requirements.
Pin “PE” on input connector is reliably connected to the case. For safety reasons it is essential to connect this pin to the protective earth.
Do not open the converters, or the warranty will be invalidated.
For more details refer to Product datasheet / Accessories datasheets (application notes) at belfuse.com/power-solutions and go to the
respective product or family part number listing.
CLEANING LIQUIDS AND PROTECTION DEGREE
The converters are not hermetically sealed. In order to avoid possible damage, any penetration of liquids shall be avoided.
The converters correspond to protection degree IP 30.
CAUTIONS
These converters are components, intended exclusively for inclusion by an industrial assembly process or by a professionally competent
person. Installation must strictly follow the national safety regulations in respect of the enclosure, mounting, creepage distances,
clearances, markings and segregation requirements of the end-use application.
This is a Class A product. In a residential environment this product may cause radio interference in which case the user may be required to
take adequate measures.
CAUTION:
Hot Surface To reduce the risk of injury avoid coming into contact with a hot surface.
Surface chaude Pour réduire le risque de blessure, évitez d'entrer en contact avec une surface chaude.
PROTECTIVE EARTHING
There’s a protective earth (PE) pin available on input connector.
FUSING
The railway standard EN 50155 does not recommended fuses in the converters. Consequently, the installer must preview an external fuse or
circuit breaker. However, when this is not possible, an incorporated fuse is available (option F). This fuse is not accessible and will not trip,
except if the converter is defect. The type of the incorporated fuses is specified in table. Such fuses are also recommended for external
fuses.
Recommended external fuses (same as with option F)
Model
Fuse type
24RCM150
15 A fast acting
24RCM300
30 A fast acting
110RCM150
5 A fast acting
110RCM300
8 A fast acting
SERVICING
The product(s) must be returned to the Authorized Bel Service Center for repair with a pre-assigned RMA number.
RCM150/300 Series Installation Instruction
2
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
© 2019 Bel Power Solutions & Protection
BCM.00549_AC
LIMITED WARRANTY
The company warrants each power supply of its manufacture for a period of five years from the date of original shipment. This warranty
applies to defects in materials and workmanship that result in non-performance to published specifications. The product(s) must be returned
to the Authorized Service Center for repair with a pre-assigned RMA number.
The company assumes no liabilities for consequential damages of any kind through the use or misuse of its products by any user. No other
obligations are expressed or implied.
Please note that the specifications, terms, and conditions stated are subject to change without notice.
INPUT AND OUTPUT CONNECTOR DETAILS
Refer to the product datasheets at belfuse.com/power-solutions.
MECHANICAL DIMENSIONS AND MOUNTING REQUIREMENTS
Refer to the product datasheets at belfuse.com/power-solutions.
ALLOWED MOUNTING POSITION
Make sure that there is sufficient airflow available for convection cooling and that the temperature of the bottom plate is within the specified
range. This should be verified by measuring the case temperature at the specified measuring point, when the converter is operated in the
end-use application. TC max should not be exceeded. Ensure that a failure of the converter does not result in a hazardous condition.
NUCLEAR AND MEDICAL APPLICATIONS
These products are not designed or intended for use as critical components in life support systems, equipment used in hazardous
environments, or nuclear control systems.
TECHNICAL REVISIONS
The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured.
Specifications are subject to change without notice.
  • Page 1 1
  • Page 2 2

BEL RCM150/300 Guide d'installation

Taper
Guide d'installation

dans d''autres langues