Tetra 12V GEPS12W-60 Signage Power Supply Guide d'installation

Taper
Guide d'installation
Installation Guide
SIGN186 | GE2022-3612
Power Supply Features
Supports all 12 VDC Tetra Products
UL: Class 2
IEC: SELV
100-240 VAC Input
For the latest North American install guides for your product go to: https://products.LED.com/led-signage-lighting
For the latest European install guides for your product go to: https://products.LED.com/eu
BG Българската версия на инструкциите за инсталаця
и информация за безопасност могат да бъдат
намерени на следния адрес: https://products.LED.
com/eu
CS Návod k montáží a bezpečnostní informace v
češtině najdete zde: https://products.LED.com/eu
DA Den danske version af installationsvejledningen
og sikkerhedsoplysninger kan findes på følgende
placering: https://products.LED.com/eu
DE Die deutsche Version der Installationsanleitung und
Sicherheitsinformationen finden Sie in folgendem
Verzeic: https://products.LED.com/eu
EL Μπορείτε να βρείτε την ελληνική εκδχή των
οδηγιών νγκατάστασης και των πληροφοριών
ασφάλειας στην εξής τοποθεσία: https://products.
LED.com/eu
ES La versión española de las instrucciones de
instalación y la información sobre seguridad puede
encontrarse en la siguiente ubicación: https://
products.LED.com/eu
ET Eestikeelse paigaldusjuhendi ja ohutusnñuded leiate
aadressilt: https://products.LED.com/eu
FI Asennusohjeiden ja turvallisuustietojen
suomenkielinen versio löytyy seuraavasta paikasta:
https://products.LED.com/eu
FR La version française des instructions d’installations
et information de sécurité est disponible à l’adresse
suivante: https://products.LED.com/eu
HR Hrvatska verzija priručnika za ugradnju i sigurnosnih
informacija nalazi se na sljedečoj lokaciji: https://
products.LED.com/eu
HU A telepítési útmutató és a biztnosági információk
magyar nyelvű változata az alábbi címen található:
https://products.LED.com/eu
IT La versione italiana del manuale di installazione
e sicurezza può essere reperita nella seguente
sezione: https://products.LED.com/eu
LT Lietuvišką diegimo instrukcijos ir saugos
informacijos versiją galima rasti šioje vietoje: https://
products.LED.com/eu
LV Uzstādīšanas instrukciju un drošības informāciju
latviešu valodā var atrast šeit: https://products.LED.
com/eu
NL De Nederlandse versie van de installatie-instructies
en veiligheidsinformatie kan op de volgende locatie
worden gevonden: https://products.LED.com/eu
PL Polską wersję instrukcji instalacji oraz informacje
dotyczące bezpieczeństwa można znaleźć w
następującej lokalizacji: https://products.LED.com/eu
PT A versão em Português das instruções de
instalação e das informações de segurança pode
ser encontrada na seguinte localização: https://
products.LED.com/eu
RO Versiunea în limba română a instrucţiunilor de
instalare şi a informaţiilor de siguranţă pot fi găsite
la: https://products.LED.com/eu
SV Ni hittar den svenska versionen
av installationsanvisningarna och
säkerhetsinformationen på följande plats: https://
products.LED.com/eu
SL Previdnostna opozorila in varnostne informacije
so na zadnji strani vodnika za namestitev. Pred
začetkom namestitve izdelka jih skrbno preberite:
https://products.LED.com/eu
SK Slovenskú verziu montažnej príručky a
bezpečnostnŷch instrukcií nájdete na nasledujúcej
lokalite: https://products.LED.com/eu
LED Systems Power Supply
GEPS12W-60 (100-240 VAC input/12VDC output/60W)
1212
Volt
EN
BEFORE YOU BEGIN
Read these instructions completely and carefully.
Prepare Electrical Wiring
Electrical Requirements
Acceptable for use in dry, damp and wet locations.
The grounding and bonding of the LED Driver shall be
done in accordance with National Electric Code (NEC)
Article 600.
Follow all National Electric Codes (NEC) and local codes.
FOR UL ONLY
Save These Instructions
Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
Tetra® Power Supply GEPS12W-60 Installation Guide
2
WARNING / AVERTISSEMENT
RISK OF ELECTRIC SHOCK
Disconnect power at fuse box or circuit breaker before servicing or
installing product.
Properly ground Tetra® power supply.
RISK OF FIRE
Minimum 10 cm (4”) to side and 2.5 cm (1”) spacing in
compartment surrounding component required.
Use only approved wire for input/output connection. Minimum size
18 AWG (0.82 mm2).
Follow all local codes.
Application considerations potentially requiring additional spacing
include high ambient temperature seen by the power supply, poor
contact with a heat dissipating material, inadequate ventilation, or
direct exposure to sun.
RISQUES DE DÉCHARGES ÉLECTRIQUES
Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur avant
l’entretien ou l’installation du produit.
Assurez-vous de correctement mettre à terre le bloc d’alimentation Tetra®.
RISQUES D’INCENDIE
Un espacement minimum de 10 cm (4 po) entre 2 alimentations de
puissance est requis ainsi qu’un espacement minimal de 2,5 cm (1 po)
avec toute enceinte.
N’utilisez que des fils approuvés pour les entrées/sorties de connexion.
Taille minimum 18 AWG (0.82 mm2).
Respectez tous les codes locaux.
Certaines applications pourraient requérir un espacement additionnel, p.
ex. une température ambiante élevée autour du bloc d’alimentation, un
mauvais contact avec une matière dissipatrice de chaleur, une ventilation
inadéquate ou une exposition directe au soleil.
Power Supply Installation
Black (-)
Green with
yellow stripe White (+)
Connect the AC line to the black
(line) and white (neutral) input
wires of the power supply using
18-14 AWG (0.82-2.08 mm2)
twist-on wire connectors.
Properly ground (green wire
with yellow stripe) power supply
in accordance with National
Electric Code (NEC) Article 600.
Power Supply
Conduit
Power Supply
input wires
AC Line
Run AC line through conduit
and attach conduit to outdoor-
rated/UL approved enclosure.
Attach power supply to
enclosure.
Connect the red stripe wire
(+) of the LED strip to the red
wire (+) of the power supply.
Connect the white wire (-) of
the LED strip to the black wire
(-) of the power supply.
To power supply
Red (+)
Red stripe (+)
White (-) Black (-)
NOTE: All electrical connections
should be made within the letter.
CAUTION / ATTENTION
RISK INJURY
While performing installations described, gloves, safety
glasses or goggles should be worn.
RISQUES DE BLESSURE
Lors de l’exécution des installations décrites, des gants, des lunettes
de sécurité ou des lunettes de protection doivent être portées.
1 2 3
Tetra® Power Supply GEPS12W-60 Installation Guide
3
OPTIONAL
A Weather Box (GEXNWB2) may be used to
house and seal Class 2 connections.
A) Insert wire connectors into weather box. Fill
with electrical grade silicone and close box.
B) Secure the weather box using a #6 or #8
(M2 or M3) screw.
Weather box
can be painted
Light engine
FOR UL ONLY
NOTE: For installation in Canada, a disconnect switch of appropriate rating needs to be placed within 29.5 feet
(9 meters) of primary side of the power supply. The switch voltage rating shall not be less than the branch circuit
voltage. The switch must also support twice the amount of input current.
FOR UL ONLY
NOTE: When installing power supply, connect to the appropriate sized building breaker or disconnect device
for line, neutral and ground connections, in accordance with National Electric Code (NEC) Article 600 and all
local regulations.
NOTE: Exceeding maximum load per bank will cause the power supply to shut down. Once the excess load is
removed, cycle the input power to restart the power supply.
NOTE: To avoid overloading this
power supply with LED modules,
please refer to the specific
module loading guides.
Mount Power Supply in a
horizontal orientation with
a minimum of one screw
per mounting plate (two
screws per power supply)
with the base in contact with
the mounting surface in
accordance with the power
supply spacing requirements
described above.
Tighten liquid-tight fittings
and properly replace cover on
junction box to ensure a water-
tight seal. If not protected
from the weather, the output
connections may be sealed
with electrical grade silicone.
4 5
A B
Tetra® Power Supply GEPS12W-60 Installation Guide
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 4 of 4
(Rev 06/19/23)
SIGN186 | GE2022-3612
Power Supply Specifications
Performance Data Min Typical Max
Input Voltage (VAC) 90 100-240 264
Input Frequency (Hz) 50/60
Input Current (A) 0.85
THD – 20
PF 0.9 –
Output Voltage (VDC) 11.4 12.0 12.6
Output Current (ADC) 0.8 5.0
Output Power (W) 60
Environmental Operating Temperature Range -40°C +25°C +60°C*
Environmental Humidity (non-condensing) 0% 95%
Environmental Storage Temperature Range -40°C +85°C
Environmental Rating IP66 Rated
Dimensions 12 in. x 2 in. x 1.25 in. (307 mm x 52 mm x 32 mm)
Conforms to the following standards:
This product is intended to be used as a lamp control gear that is installed after the mains control switch.
*Maximum case temperature is 80°C
Symptom Solution
All letters are OFF Recycle AC power, turn it off, then turn on again.
If still off, check the power supply DC output voltage using a voltmeter. It should be nominally 12V.
» If there is DC output, inspect and correct all DC wire damage/polarity issues; If no issue is found, replace the
OFF-module string.
» If there is no DC output, have a licensed electrician check the input AC voltage and if there is correct AC voltage,
replace the power supply.
» If there is no AC voltage, correct the upstream AC issue.
Some LEDs appear dim Ensure the overall length of the Tetra® LED System does not exceed the maximum load.
Ensure the length of supply wire is equal to or below the recommended remote mounting distance.
Some of the letters
are not illuminated
Inspect and correct the wires of the non-illuminated letters for damage/polarity issues; If no issues are found, see the
troubleshooting solution for “All letters are OFF.”
Shadows Re-route supply wire and secure to the back of the can with electrical grade RTV silicone. Adjust wire connector
orientation so that it does not cover any LEDs.
Adjust LED layout to ensure uniformity of illumination of the face of the letter.
Troubleshooting
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005 du Canada.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Tetra 12V GEPS12W-60 Signage Power Supply Guide d'installation

Taper
Guide d'installation