Installation Guide
SIGN108
Junction Box Features
Installation
Remove screw and lock washer and snap the top
cover off of the junction box.
Select a wire entry knock out location and carefully
remove metal plug. Install wire box fitting and supply
wire and secure in place.
• GEPSJB60 supports: GEPS12-60, GEPS12D-60U, GEPS24-80, GEPS24D-80U,
• GEPS12-60U-NA, GEPS12SE-60U-NA, GEPS12-60U-GL, GEPS24-100U-NA,
• GEPS24-100U-GL, GEPS24-100U-GLX
• Can be used on primary side of the power supplies listed above; or any other
power supply that similarly fits, with a class 2 output where otherwise acceptable
in the application.
• Suitable for dry or damp locations
1 2
Power Supply Junction Box
GEPSJB60
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING / AVERTISSEMENT
RISK OF ELECTRIC SHOCK:
• Disconnect power at fuse box or circuit breaker before servicing
or installing product.
• Properly ground Tetra® power supply.
RISK OF FIRE:
• Use only approved wire for input/output connection. Minimum
size 18 AWG (0.82 mm2).
• Use only approved wire for input connection. Maximum size 14
AWG; minimum 75C rated.
• Branch circuit limit of 15A.
• Follow all local codes.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur
avant l’entretien ou l’installation du produit.
• Assurez-vous de correctement mettre à terre l’alimentation électrique Tetra®.
RISQUES D’INCENDIE
• N’utilisez que des fils approuvés pour les entrées/sorties de connexion. Taille
minimum 18 AWG (0.82 mm2).
• N’utilisez que des fils approuvés pour les entrées/sorties de connexion. La
taille maximale 14 AWG; minimum 75C nominale.
• Respectez tous les codes locaux.