Good Earth Lighting LF1089-PEW-52LF4 Mode d'emploi

Taper
Mode d'emploi
Need Help?
Please visit our website at:
www.goodearthlighting.com/support
or call the customer care center
1-800-291-8838
8:30 a.m.-5 p.m., CST, Monday-Friday.
Besoin d’aide?
Visitez notre site Web au
www.goodearthlighting.com/support ou
communiquez avec notre service à la clientèle
au 1 800 291-8838, entre 8 h 30 et 17 h (HNC),
du lundi au vendredi.
¿Necesita ayuda?
Visite nuestro sitio web en:
www.goodearthlighting.com/support o llame
al Centro de Servicio al Cliente, al
1-800-291-8838, de 8:30 a.m. a 5 p.m., hora
central estándar, de lunes a viernes.
http://www.goodearthlighting.com/
52-tacoma-led-linear-decorative.html
See link or scan
for installation video.
Voir le lien ou le code à
balayer pour visionner
la vidéo relative à l’installation.
Vea el enlace o escanee para
acceder al video de instalación.
INSTALLATION OVERVIEW
PRÉSENTATION GÉNÉRALE DE L’INSTALLATION
GENERALIDADES SOBRE LA INSTALACIÓN
Panel
Panneau
Panel
E
F
S
Frame
Cadre
Armazón
E
F
S
Mounting Plate
Plaque de montage
Placa de montaje
E
F
S
Model / Model / Modelo #: LF1089-PEW-52LF4-G
52 in. Tacoma LED linear ceiling fixture
(Page 2)
Luminaire de plafond linéaire à DEL Tacoma de 52 po / 132 cm
Accesorio para iluminación LED de techo lineal
Tacoma de 52 pulgadas
Required
Nécessaire
Se necesita
Hardware kit* / Kit de petit matériel de
fixation* / Kit de herrajes*
*Actual hardware may differ from illustration
*Les éléments de fixation réels peuvent être différents de ceux de l’illustration.
*Los herrajes reales pueden diferir de los que se muestran en la ilustración
DD
x3
CC
x4
AA
x2
BB
x4
EE
x4
FF
x2
1/8 in.
1/8 po
0,3 cm
Warnings and Cautions
2
Shut off power at the circuit breaker or fuse panel before removing the old fixture or installing the new one.
LEDs can be damaged by electrostatic discharge shock. Before installation, discharge yourself by touching a grounded bare metal surface to remove
this hazard.
For INDOOR use only. For electrical requirements, see fixture. Minimum 90° supply conductors. The luminaire shall be used for class 1 wiring.
THIS FIXTURE IS DIMMABLE BY TRIAC DIMMERS AND IS NOT COMPATIBLE WITH 0-10V DIMMING SYSTEMS. Dimmers tested to be
compatible with this fixture are the Lutron: Diva® C•L™: DVWCL-153PH, Lumea® C•L™: LGCL-153PLH, and Toggler® C•L™: TGCL-153PH. (This
list of dimmers does not imply any guarantee or warranty of compatibility with a particular application. Dimmers not listed do not imply non-compati-
bility.)
If unsure if the electrical box is properly grounded, or the box is plastic and has no ground wire, or are unfamiliar with the methods of properly
grounding fixture, consult a qualified electrician.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
The user is cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures:
1) Reorient or relocate the receiving antenna. 2) Increase the separation between the equipment and receiver. 3) Connect the equipment into an outlet on a circuit different from that
of the receiver. 4) Consult the dealer or an experienced radio/TV technician for help.
12
To attach the mounting plate to the junction box, first hold the mounting plate up to the junction box in the desired orientation you want the fixture to be
mounted. Identify the set of mounting keyholes that align closest with the screws in the junction box. Pull black, white and ground supply wires from
electrical box through the hole in center of mounting plate. Ground wires can be either green or bare copper. Insert first screwhead into straight
keyhole slot , pivot mounting plate and insert second screw into curved keyhole slot . Once screws are engaged, maneuver mounting plate into
desired position. Tighten screws.
2B
English
Attach fixture mounting screws (AA) into electrical box and leave extended about a 3/8 in.
2A
To remove mounting plate, place the fixture face down. The instructions are written for the side marked with “STAND ON THIS SIDE” facing the
installer. The shift-frame needs to be unlocked to remove mounting plate for installation. Locate the lock sticker and rotate the locking mechanism
90° counter-clockwise . This allows the mounting bracket to slide to the left about an inch. In a continuous motion, push the entire mounting plate to
the left and once the lip of the mounting plate is free of the stationary end of the shift frame , angle up and remove .
1
2
3 4
1
See link or scan for installation video.
www.goodearthlighting.com/
28-tacoma-led-linear-decorative.html
2A 2B
AA x2
1
2
1
2
MOUNTING INSTRUCTIONS
Read all steps to familiarize yourself with the entire mounting procedure before starting.
The next set of steps illustrates the lift and shift procedure to hook the fixture assembly to the mounting plate. Refer to these as you read through the
directions. Familiarize yourself with the mechanics of the mounting hardware on the back side of the fixture. The backside of fixture has a movable spring
loaded rail. There is also a rotating locking lever above the lock arrow. Notice when in the closed position, the rail will not slide. This lock must be rotated
open during the mounting procedure and closed after fixture is successfully mounted.
Stand on the side of fixture where the lock indicated with an arrow on the frame is located. Getting help if needed, hold fixture up to secured mounting
plate and attach the support wire hooks from the backside of fixture to specially designed slots in mounting plate. NOTE: Insert hook into large slot and
out the smaller hole. Allow fixture to hang, tilted to one side, for wiring.
3
Locate the open holes for mounting at the corners of mounting plate and drill a 1/8 in. pilot hole in the center. If a wooden stud is encountered, use the
wood screws (BB) and washers (EE) provided to secure mounting plate directly to stud.
If no stud is encountered, place the drywall anchors (CC) in the pilot holes and screw them into place until flushed with surface of drywall. Place
washer (EE) over the mounting hole and drive long screws (BB) into drywall anchor until snug. DO NOT OVERTIGHTEN. NOTE: Main support for
mounting plate is provided by attaching to a securely mounted electrical box. If the electrical box is not properly secured, alternative mounting methods
such as toggle bolts (not included) should be used to secure mounting plate.
3A
3B
4
3B
With Wood Stud
Drywall Without Wood Stud
3A
EE x4
BB x4
1/8 in. 1/8 in.
3B
EE x4
BB x4 CC x4
Fixture must be properly grounded. Connect mounting plate ground wire and fixture ground wire to green or bare copper ground wire in electrical box
using wire nut (DD).
Connect white wires, one from each driver, to white supply lead in electrical box using wire nut (DD). Connect black wires, one from each driver, to
black supply lead in electrical box using wire nut (DD). Use cable ties (FF) to secure loose fixture wires to one another in center of mounting plate to
keep them from getting in the way during fixture mounting.
Connect the connector from mounting plate driver to the connector from the fixture.
Place hand over handprint in Box A and lift this side up to the ceiling, being careful not to scratch ceiling.
4
5A
5B
6A
Keeping one hand on Box A, slide fixture over (Box B) while raising the other end of the fixture up to the ceiling. You should feel the rail on the fixture
hook the edge of the mounting plate and slide to the open position (Fig. 1).
With the fixture fully engaged with the mounting plate, slide the fixture back to the opposite side (Box C), allowing the fixed rail to hook the other end of
the mounting plate (Fig. 2).
6B
6C
5
Good Earth Lighting® - 10 YEAR LIMITED WARRANTY
The manufacturer warrants this lighting fixture to be free from defects in materials and workmanship for a period of (10) years from the date of original purchase by the
consumer. The fixture is not warrantied for use in a commercial or retail application. The warranty is limited to use in a residential environment. We will repair or replace (at our
option) the unit in the original color and style if available, or in a similar color and style if the original item has been discontinued, without charge. Defective units must be
properly packed and returned to the manufacturer with a letter of explanation and your original purchase receipt showing date of purchase. Call 1-800-291-8838 to obtain a
return authorization number and an address where to ship your defective product. Note: C.O.D. shipments will NOT be accepted. The liability of the manufacturer is in any
case limited to replacement of the defective light fixture product. The manufacturer will not be liable for any other loss, damage, labor costs or injury which is caused by the
product. This limitation upon the liability of the manufacturer includes any loss, damage, labor costs or injury which is (I) to person or property or otherwise; (II) incidental or
consequential in nature; (III) based upon theories of warranty, contract, negligence, strict liability, tort, or otherwise; or (IV) directly, or indirectly related to the sale, use, or repair
of the product. This warranty gives you specific rights, and you may also have other rights which vary from state to state.
Troubleshooting Guide
Fixture doesn’t light.
Problem Cause Solution
Fuse blows or circuit breaker trips
when light is turned on.
Power is off.
Bad connection.
Bad switch.
Discontinue use.
Check if power supply is on.
Check cords and/or wiring.
Test or replace switch.
Call customer service.
Before doing any work on the fixture, shut off power supply at the circuit breaker panel to avoid electrical shock.
Hardware Kit:
ZH-LF1089F52-PEW
Replacement Parts List
SAVE THESE INSTRUCTIONS.
Printed in China
Good Earth Lighting
®
1400 East Business Center Drive, Ste. 108 Mount Prospect, IL 60056
6
Slowly release fixture making sure it stays in place. To lock the fixture in place, extend hand over the frame above the lock arrow and rotate the rail
locking lever into place (Fig. 3). If lever does not rotate fully into place, the panel is not positioned properly. Manuever fixture until it seats properly or
repeat mounting steps if needed until locking lever rotates into place.
Restore power once fixture is properly installed.
7
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Good Earth Lighting LF1089-PEW-52LF4 Mode d'emploi

Taper
Mode d'emploi