Baumer FHCK 07N6901 Mode d'emploi

Taper
Mode d'emploi
FHCK 07N6901
10152083
Í?*/4sÂÂ*ÂWÎ
1/2
IND. CONT. EQ
1DD2
Optoelektronische Sensoren
Photo electric sensors
Cellules opto-électroniques
Reflexions-Lichttaster mit
Hintergrundausblendung
Diffuse sensor with
background suppression
tecteur réflex avec
élimination de l'arrière plan
Canada
Baumer Inc.
CA-Burlington, ON L7M 4B9
Phone +1 (1)905 335-8444
China
Baumer (China) Co., Ltd.
CN-201612 Shanghai
Phone +86 (0)21 6768 7095
Denmark
Baumer A/S
DK-8210 Aarhus V
Phone: +45 (0)8931 7611
France
Baumer SAS
FR-74250 Fillinges
Phone +33 (0)450 392 466
Germany
Baumer GmbH
DE-61169 Friedberg
Phone +49 (0)6031 60 07 0
India
Baumer India Private Limited
IN-411058 Pune
Phone +91 20 66292400
Italy
Baumer Italia S.r.l.
IT-20090 Assago, MI
Phone +39 (0)2 45 70 60 65
Singapore
Baumer (Singapore) Pte. Ltd.
SG-339412 Singapore
Phone +65 6396 4131
Sweden
Baumer A/S
SE-56133 Huskvarna
Phone +46 (0)36 13 94 30
Switzerland
Baumer Electric AG
CH-8501 Frauenfeld
Phone +41 (0)52 728 1313
United Kingdom
Baumer Ltd.
GB-Watchfield, Swindon, SN6 8TZ
Phone +44 (0)1793 783 839
USA
Baumer Ltd.
US-Southington, CT 06489
Phone +1 (1)860 621-2121
www.baumer.com/worldwide
Baumer Electric AG · CH-8501 Frauenfeld
Phone +41 (0)52 728 1122 · Fax +41 (0)52 728 1144
Abmessungen
Dimensions
Dimensions
10,8
4,6
7,56,2
ø 5,2
LED
Teach-in
* 2,3 6
9,2
16,2
8
3
18
23,5
21,4
12,4
15,4
13,4
3
,
2
2
x
ø
10,7
3
ø
1,58,25
9,3
Alle Masse in mm
• All dimensions in mm
Toutes les dimensions en mm
* Senderachse
* Emitter axis
* Axe de l'émetteur
Elektrischer Anschluss
Connection diagram
Schéma de raccordement
0 V
NPN
WH (2)
BU (3)
BN (1)
BK (4)
Z
+VS
light/dark
ext. teach
Im Normalbetrieb die Teach-in Leitung auf 0V (PNP) bzw. +Vs (NPN) legen
Um die Immunität bezüglich elektromagnetischer Verträglichkeit zu erhöhen, wird empfohlen den Sensor mit der mitgelieferten Isolierplatte zu montieren
To increase the immunity regarding electromagnetic compatibility, it is recommended to install the sensor with the insulation plate provided
Pour augmenter l'immunité en ce qui concerne la compatibilité électromagnétique, il est recommandé d'installer le détecteur avec la plaque d'isolation fournie
In normal operation, set the teach-in line at 0V (PNP) or + Vs (NPN)
En fonctionnement normal, réglez l'apprentissage en ligne à 0V (PNP) ou + Vs (NPN)
•Anschlussleitung nicht unter Zug verlegen.
•Do not install the cable under tension.
•Eviter tout effort de traction sur le câble de raccordement lors de sa pose.
• Vor dem Anschliessen des Sensors die Anlage spannungsfrei schalten.
• Disconnect power before connecting the sensor.
• Mettre l`installation hors tension avant le raccordement du détecteur.
Technische Daten
Technical data
Données techniques
Betriebsspannungsbereich Vs (UL-Class 2) Voltage supply range Vs (UL-Class 2) Plage de tension Vs (UL-Class 2)
max. Stromverbrauch Mittel- / Spitzenwert max. supply current average / peak Consommation moyenne / pointe max.
max. Schaltstrom max. switching current Courant de sortie
max.
Spannungsabfall Voltage drop Tension résiduelle
Ansprechzeit Response time Temps d'activation
Abfallzeit Release time Temps désactivation
Kurzschlussfest Short circuit protection Protégé contre courts-circuits
Verpolungsfest Reverse polarity protection Protégé contre inversion de polarité
Betriebstemperatur Temperature range Température de service
Schutzklasse Protection class Classe de protection
max. Anzugsdrehmoment max. tightening torque Couple max. de serrage
Tastweite einstellbar Tw Sensing distance adjustable Tw Portée ajustable Tw
Tastbereich Tb bei Tw = 60 mm Sensing distance Tb at Tw = 60 mm Plage de détection Tb à Tw = 60 mm
Tastbereich Tb bei Tw = 10 mm Sensing distance Tb at Tw = 10 mm Plage de détection Tb à Tw = 10 mm
10 - 30 VDC
20 mA / 25 mA
100 mA
1,8 VDC
0,5 ms
0,5 ms
ja / yes / oui
ja / yes / oui
-20...+50 °C
IP 65
0,35 Nm
10...60 mm
2...60 mm
5...10 mm
Technische Änderungen vorbehalten Technical specifications subject to change Sous réserve de modifications techniques
2/2
Teach-in Abläufe
Teach-in procedures
Procédures de Teach-in
Anzeigeelemente / Bedienungselemente
- LED grün: Empfangsanzeige
- LED grün blinkend: Einstellhilfe / Verschmutzungsanzeige
- LED gelb: Ausgangsanzeige
- Taste: Teach-in
Statischer Teach-in Ablauf, für ruhende Objekte
1. Den Sensor in den statischen Teach-in-Modus bringen:
Taste ca. 2 sek drücken bis die LED (grün) blinkt
2.Das Objekt in die gewünschte ON-Position bringen und
Taste kurz drücken
3.Das Objekt in die gewünschte OFF-Position bringen und
Taste kurz drücken
Dynamischer Teach-in Ablauf, r bewegte und kleine Objekte
1. Den Sensor in den dynamischen Teach-in-Modus bringen:
Taste ca. 5 sek drücken bis das Blinken der LED (grün)
von langsam nach schnell wechselt
Nach Loslassen der Taste beginnt der Sensor sofort mit dem
Einlernen der Minimal- und Maximalwerte
2.Teach-in beenden: Taste kurz drücken
3.Ausgangsfunktion von Hellschaltung (Standard) auf
Dunkelschaltung wechseln: Taste innerhalb 5 sek nach
"Teach-in beenden" kurz drücken
Teach Feedback nach dem Teach-in Ablauf
Teach-in OK; LED (grün) leuchtet für 2 sek:
- Die eingelernte Anwendung arbeitet einwandfrei mit
genügend Unterschied der Lernpunkte und
innerhalb vom Erfassungsbereich des Sensors
Teach-in Warnung; LED (grün) blinkt für 2 sek:
- Die Differenz zwischen den Lernpositionen ist zu klein für eine
sichere Anwendung oder
- Der Sensor wurde ausserhalb seiner Bereichsgrenze eingelernt
Display elements / Operating elements
- Green LED: excess gain indicator
- Green LED flashing: alignment aid / soiled lens indicator
- Yellow LED: output indicator
- Button: Teach-in
Static Teach-in procedure, for non moving parts
1. Set the sensor into static Teach-in mode:
press the button approx. 2 sec until LED (green) is flashing
2.Set the object to the desired ON-position and
press the button shortly
3.Set the object to the desired OFF-position and
press the button shortly
Dynamic Teach-in procedure, for moving and small objects
1. Set the sensor into dynamic Teach-in mode:
press the button approx. 5 sec until LED (green) flashing
changes from slow to fast
After releasing the button, the sensor starts immediately to
sense the max. and min. values
2.Stop the Teach-in procedure: press the button shortly
3.To change the output function from light operate (standard)
to dark operate: press the button within 5 sec after "stop the
Teach-in procedure" shortly
Teach feedback after Teach-in procedure
Teach-in OK; LED (green) is on for 2 sec:
- The teached application is OK, within its sensing range and
there is enough difference between the teached values
Teach-in warning; LED (green) is flashing for 2 sec:
- The difference between the 1st and 2nd teach position is too
small for a safe application or
- The sensor is teached beyond its sensing range
Eléments d'affichage / Éléments opérationnels
- LED verte: témoin de réception
- LED verte clignotante: aide de réglage / contrôle d'encrassement
- LED jaune: témoin de sortie
- Touche: Teach-in
Teach-in statique, pour objets fixes
1. Appuyez env. 2 sec sur la touche Teach-in jusqu'à ce que la LED
(verte) clignote
2.Mise en place de l'objet dans la ON-position
appuyer sur la touche Teach-in
3.Mise en place de l'objet dans la OFF-position
appuyer sur la touche Teach-in
Teach-in dynamique, pour de petits objets ou objets en mouvement
1. Appuyez env. 5 sec sur la touche Teach-in jusqu'à ce que la LED
(verte) clignote plus rapidement
Dès que vous relachez la touche Teach-in, le capteur commence
à enregistrer les valeurs min. et max. du signal
2.Terminer le cycle Teach-in: appuyez sur la touche Teach-in
3.La fonction standard mémorisée est la commutation claire
Pour une commutation sombre, appuyez sur la touche Teach-in
encore une fois dans les suivant 5 sec
Teach feedback après le Teach-in
Teach-in OK; LED (verte) s'allume pendant 2 sec:
- L'application travaille correctement, avec suffisamment de
différence de signal pour la reconnaissance des 2 points et
dans la portée du capteur
Alerte Teach-in; LED (verte) clignote pendant 2 sec:
- La différence entre le premier et le second point mémorisés est
trop petite pour une application sûre ou
- Le capteur a été utilisé hors des limites spécifiées
4.Bei Tauschen der Punkte 2 und 3, wird der Sensor auf Dunkel-
schaltung umgestellt, andernfalls hellschaltend
4.The sensor is set to dark operate by interchanging the order
of items 2 and 3, otherwise it is set to light operate.
4.En inversant l’ordre 2 et 3, le détecteur est commuté sur com-
mutation sombre sinon il reste en commutation claire
FAQ
1. How to teach using the external wire input?
Same teach procedure as with the button. Instead of pressing
the button connect Teach-in input to +Vs (PNP) or 0V (NPN).
Teach feedback: Output open = Teach-in OK
Output closed = Teach-in warning
2. How to teach on maximum sensitivity / sensing range?
Cover the receiver lens. Go into the dynamic Teach-in mode.
After stopping the Teach-in procedure, press the button once
more to switch the output to dark operate, if desired.
3. What happens when ON- and OFF-Position are the same?
Even if there is no difference between the two signals, the
switching point is set on this position as good as possible.
4. Why is the green LED flashing?
- The sensor is operated at too little signal reserve.
- The sensor is inside a Teach-in procedure.
- Teach feedback: too little signal difference for a safe application
(2 sec fast flashing).
- Option to switch to dark operate (5 sec double flashing).
1. Comment fonctionne le Teach-in externe?
Exactement comme pour la touche Teach-in, en raccordant l'entrée
Teach-in externe avec +Vs pour PNP (0V pour NPN).
Teach feedback:
2. Comment adjuster à la sensibilité maximale / plage de détection?
Couvrir la lentille du récepteur de façon à prévenir la réception de
signal. Démarrer un Teach-in dynamique. Après avoir terminé le
Teach-in, il est possible de changer la sortie en commutation sombre.
3. Qu'est-ce qui ce passe si ON- et OFF-position sont les mêmes?
Même si la différence entre les deux positions est zéro, le capteur
choisi le point de commutation le plus proche possible.
4. Pourquoi est-ce que la LED verte clignote?
- Le capteur travaille avec insuffisament de réserve de signal.
- Le capteur se trouve dans une procédure de Teach-in.
- Teach-in avec insuffisament de différence (2 sec, rapide).
- Possibilité de changer en commutation sombre (5 sec, double).
Sortie non commutée = Teach-in OK
Sortie commutée = alerte Teach-in
1. Wie funktioniert der externe Teach-in-Vorgang?
Er ist identisch zur Taste, indem man den Teacheingang auf +Vs
bei PNP, ( 0V bei NPN ) verbindet.
Teach Feedback: Ausgang offen = Teach-in OK
Ausgang geschalten = Teach-in Warnung
2. Wie teacht man auf max. Empfindlichkeit / Tastweite?
Den Empfänger so abdecken dass er kein Licht mehr empfängt.
Dann in den dynamischen Teach-in-Modus gehen. Nach beenden
des Teach-in, kann noch auf Dunkelschaltung gewechselt werden.
3. Was passiert wenn die ON- und OFF-Position gleich sind?
Obwohl die Differenz zwischen den Lernpunkten Null ist, wird
der Schaltpunkt möglichst genau auf diese Position eingestellt.
4. Wieso blinkt die grüne LED?
- Der Sensor arbeitet mit ungenügender Signalreserve.
- Man befindet sich im Teach-in-Modus.
- Teach-in mit zu wenig Differenz zwischen den Lernpositionen
(2 sek schnelles Blinken).
- Möglichkeit auf dunkelschaltend zu stellen (5 sek, doppel).
Montage Mounting Montage
Baumer
electric
Swiss made
Baumer
electric
Swiss made
Baumer
electric
Baumer
electric
Hinweis: Für Montage und Inbetriebnahme sind geeignete ESD-
Schutzmassnahmen zu ergreifen. Empfehlung: als Minimal-ESD-
Schutzmassnahme ist der Metallrahmen anzufassen, an dem der
Sensor montiert ist, bevor der Sensor geteachet wird.
Note: proper ESD precautions should be taken for erection and
commissioning. Recommendation: as minimum ESD protection
measure, the metal frame is to touch, to which the sensor is
mounted before the sensor is taught.
Remarque: mesures de protection ESD appropriées doivent être prises
pour le montage et la mise en service. Recommandation: minimum
comme mesure de protection ESD, la structure métallique est au
toucher, à laquelle le capteur est monté devant le capteur est enseigné.
  • Page 1 1
  • Page 2 2

Baumer FHCK 07N6901 Mode d'emploi

Taper
Mode d'emploi