Kichler Lighting 45885NI Manuel utilisateur

Taper
Manuel utilisateur
Date Issued: 09/18/17 IS-45885-CB
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starting and during the installation.
1) Find the appropriate threaded holes on mounting strap[1]
that align with hole distance in canopy[2] Thread mounting
screws[3] into threaded holes starting from outlet box[4] side.
2) Attach mounting strap to outlet box with strap mounting
screws[5]. Mounting strap can be adjusted to suit position of
xture.
3) Grounding instructions: (See Illus. A or B)
A) Onxtureswheremountingstrapisprovidedwithahole
and two raise dimples. Wrap ground wire from outlet box
around green ground screw, and thread into hole.
B) Onxtureswhereacuppedwasherisprovided.Put
ground wire from outlet box under cupped washer and
green ground screw and thread screw into hole in mount-
ing strap.
Ifxtureisprovidedwithgroundwire.Connectxtureground
wire to outlet box ground wire with wire connector, after follow-
ingtheabovesteps.Neverconnectgroundwiretoblackor
white power supply wires.
4) Makewireconnections.Referencechartbelowforcorrectcon-
nections and wire accordingly
5) Pushxturetowallcarefullypassingmountingscrewswith
holesincanopy.Makesureallwiresareinsidecanopyanddo
notgetpinchedbetweenwallandcanopyofxture.
6) Threadlockupknobs[6] onto mounting screws and tighten to
securexturetowall.
7) Carefullyraiseglass[7]tothexture.Slipthesmalleropening
overthesocket[8]andttheglassagainstthesocket.
8) Threadthesocketring[10]ontothesocket.Tightensocketring
tosecureglassinplace(DONOTovertighten).
9) Insert recommended bulb (not supplied).
10) Repeatsteps7-9forremainingsockets.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
A
B
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
4
3
1
2
8
6
7
9
5
Date Issued: 09/18/17 IS-45885-CB
INSTRUCTIONS
For Assembling and Installing Fixtures in Canada
Pour L’assemblage et L’installation Au Canada
Nous sommes là pour vous aider 866-558-5706
Heures : du lundi au vendredi, de 9h à 17h (heure de l’Est)
ATTENTION – RISQUE DE DÉCHARGES ÉLECTRIQUES -
Couper le courant au niveau du panneau du disjoncteur du
circuit principal ou de la boîte à fusibles principale avant de
procéder à l’installation.
1) Trouvezlestrousletésappropriéssurlasangledemontage
[1]quis’alignentavecladistancedutroudanslacanopée[2]
Visdexationduletage[3]danslestrousletésàpartirdu
côtésortie[4]côté.
2) Fixezlasangledemontageàlaboîtedesortieaveclesvis
dexationdelasangle[5].Lasangledemontagepeutêtre
régléeenfonctiondelapositionduluminaire.
3) Connecterlesls.Seporterautableauci-dessouspourfaireles
connexions.
4) Enfoncezl’appareilsurlemurenpassantsoigneusementles
visdemontageavecdestrousdanslecapot.Assurez-vous
quetousleslssontàl’intérieurdelacanopéeetnepasêtre
pincésentrelemuretlacanopéedel’appareil.
5) Remplacezlesboutonsdeverrouillage[6]surlesvisdemon-
tageetserrezpourxerleluminaireaumur.
6) Éleversoigneusementleverre[7]àl’appareil.Glissez
l’ouverturepluspetitesurladouille[8]etajustezleverrecon-
treladouille.
7) Enlezladouille[10]surlaprise.Serrezladouillepourxerle
verreenplace(PAStropserrer).
8) Répétezlesétapes6-8pourlesprisesrestantes.
9) Installerlaoulesampoulesrecommandées(nonfournies).
Connecter le fil noir ou
rouge de la boite
Connecter le fil blanc de la boîte
A Noir A Blanc
*Au cordon parallèle (rond et lisse)
*Au cordon parallele (à angles droits el strié)
Au bransparent, doré, marron, ou
noir sans fil distinctif
Au transparent, doré, marron, ou
noir avec un til distinctif
Fil isolé (sauf fil vert) avec
conducteur en cuivre
Fil isolé (sauf fil vert) avec
conducteur en argent
*Remarque: Avec emploi d’un fil paralléle
(SPT I et SPT II). Le fil neutre est á angles
droits ou strié et l’autre fil doit étre rond ou
lisse (Voir le schéma).
Fil Neutre
4
3
1
2
8
6
7
9
5
  • Page 1 1
  • Page 2 2

Kichler Lighting 45885NI Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues