Simplicity 030667-01 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur

Ce manuel convient également à

BRIGGS & STRATTON CORPORATION
MILWAUKEE, WISCONSIN, U.S.A.
Manual No. 80021674 Revision A
Portable Generator
Operator’s Manual
Generator certified in accordance with CSA (Canadian Standards Association) standard C22.2 No. 100-14, Motors and Generators.
2 www.powerboss-equipment.com
Thank you for purchasing this quality-built PowerBoss® generator. We are pleased that you’ve placed your
confidence in the PowerBoss brand. When operated and maintained according to the instructions in this manual,
your PowerBoss generator will provide many years of dependable service.
This manual contains safety information to make you aware of the hazards and risks associated with generator
products and how to avoid them. This generator is designed and intended only for supplying electrical power
for operating compatible electrical lighting, appliances, tools and motor loads, and is not intended for any other
purpose. It is important that you read and understand these instructions thoroughly before attempting to start or
operate this equipment. Save these original instructions for future reference.
This generator requires final assembly before use. Refer to the Assembly section of this manual for
instructions on final assembly procedures. Follow the instructions completely.
Where to Find Us
You never have to look far to find Briggs & Stratton support and service for your generator. Consult your Yellow
Pages. There are over 30,000 Briggs & Stratton authorized service dealers worldwide who provide quality service.
You can also contact Briggs & Stratton Customer Service by phone at (800) 743-4115, or on the Internet at
www.powerboss-equipment.com.
Generator
Model Number _____________________________
Revision __________________________________
Serial Number ______________________________
Date Purchased ___________________________
Engine
Model Number _____________________________
Type Number ______________________________
Serial Number ______________________________
Table of Contents
Operator Safety..................................................3
Assembly.......................................................8
Features and Controls ...........................................11
Operation......................................................13
Maintenance ...................................................16
Troubleshooting ................................................21
Warranty ......................................................24
Product Specifications ...........................................26
Common Service Parts ..........................................26
Copyright © 2017. Briggs & Stratton Corporation
Milwaukee, WI, USA. All rights reserved.
POWERBOSS is a registered trademark of
Briggs & Stratton Corporation
3
Operator Safety
Safety Labels
The generator safety labels shown below and on the next page are placed on your portable generator to draw
attention to potential safety hazards.
4 www.powerboss-equipment.com
5
Equipment Description
Read this manual carefully and become
familiar with your generator. Know its
applications, its limitations and any
hazards involved.
The generator is an engine–driven, revolving field,
alternating current (AC) generator. It was designed
to supply electrical power for operating compatible
electrical lighting, appliances, tools and motor loads.
The generator’s revolving field is driven at about
3,600 rpm by a single-cylinder engine.
NOTICE
Exceeding generators wattage/amperage
capacity could damage generator and/or electrical
devices connected to it.
DO NOT exceed the generator’s wattage/amperage
capacity. See Generator Capacity.
Every effort has been made to ensure that the
information in this manual is both accurate and current.
However, the manufacturer reserves the right to
change, alter or otherwise improve the generator and
this documentation at any time without prior notice.
The Emission Control System for this generator is
warranted for standards set by the Environmental
Protection Agency and the California Air Resources
Board.
This spark ignition system complies with the Canadian
standard ICES-002.
Important Safety Information
The manufacturer cannot possibly anticipate every
possible circumstance that might involve a hazard.
The warnings in this manual, and the tags and decals
affixed to the unit are, therefore, not all-inclusive.
If you use a procedure, work method or operating
technique that the manufacturer does not specifically
recommend, you must satisfy yourself that it is safe
for you and others. You must also make sure that the
procedure, work method or operating technique that
you choose does not render the generator unsafe.
Safety Symbols and Meanings
The safety alert symbol indicates a potential
personal injury hazard. A signal word (DANGER,
WARNING, or CAUTION) is used with the alert symbol
to designate a degree or level of hazard seriousness.
A safety symbol may be used to represent the type of
hazard. The signal word NOTICE indicates information
considered important, but not hazard-related.
DANGER indicates a hazard which, if not avoided,
will result in death or serious injury.
WARNING indicates a hazard which, if not
avoided, could result in death or serious injury.
CAUTION indicates a hazard which, if not avoided,
could result in minor or moderate injury.
NOTICE indicates information considered important,
but not hazard-related.
Fire
Explosion
Toxic Fumes
Hot Surface
Moving Parts
Electrical Shock
Kickback
Flying Objects
Operator’s Manual
6 www.powerboss-equipment.com
WARNING The engine exhaust from this
product contains chemicals known to the State of
California to cause cancer, birth defects, or other
reproductive harm.
WARNING Certain components in this product
and related accessories contain chemicals known to
the State of California to cause cancer, birth defects or
other reproductive harm. Wash hands after handling.
WARNING
This generator does not meet U. S. Coast Guard
Regulation 33CFR-183 and should not be used on
marine applications.
Failure to use the appropriate U. S. Coast Guard
approved generator could result in death or serious injury.
WARNING POISONOUS GAS HAZARD.
Engine exhaust contains carbon monoxide,
a poisonous gas that could kill you in
minutes. You CANNOT smell it, see it, or
taste it. Even if you do not smell exhaust fumes, you
could still be exposed to carbon monoxide gas.
Operate this product ONLY outside far away from
windows, doors and vents to reduce the risk of carbon
monoxide gas from accumulating and potentially being
drawn towards occupied spaces.
Install battery-operated carbon monoxide alarms or
plug-in carbon monoxide alarms with battery back-up
according to the manufacturer’s instructions. Smoke
alarms cannot detect carbon monoxide gas.
DO NOT run this product inside homes, garages,
basements, crawlspaces, sheds, or other partially-
enclosed spaces even if using fans or opening doors
and windows for ventilation. Carbon monoxide can
quickly build up in these spaces and can linger for hours,
even after this product has shut off.
ALWAYS place this product downwind and point the
engine exhaust away from occupied spaces.
If you start to feel sick, dizzy, or weak while using this
product, shut it off and get to fresh air RIGHT AWAY. See
a doctor. You may have carbon monoxide poisoning.
WARNING Fuel and its vapors are extremely
flammable and explosive which
could cause burns, fire or explosion
resulting in death or serious injury.
WHEN ADDING OR DRAINING FUEL
Turn generator engine OFF and let it cool at least 2
minutes before removing fuel cap. Loosen cap slowly to
relieve pressure in tank.
Fill or drain fuel tank outdoors.
DO NOT overfill tank. Allow space for fuel expansion.
If fuel spills, wait until it evaporates before starting engine.
Keep fuel away from sparks, open flames, pilot lights,
heat, and other ignition sources.
Check fuel lines, tank, cap and fittings frequently for
cracks or leaks. Replace if necessary.
DO NOT light a cigarette or smoke.
WHEN STARTING EQUIPMENT
Ensure spark plug, muffler, fuel cap, and air cleaner are
in place.
DO NOT crank engine with spark plug removed.
WHEN OPERATING EQUIPMENT
DO NOT operate this product inside any building,
carport, porch, mobile equipment, marine applications, or
enclosure.
DO NOT tip engine or equipment at angle which causes
fuel to spill.
DO NOT stop engine by moving choke control to CHOKE
( ) position.
WHEN TRANSPORTING,
MOVING OR REPAIRING EQUIPMENT
Transport/move/repair with fuel tank EMPTY or with fuel
shutoff valve OFF.
DO NOT tip engine or equipment at angle which causes
fuel to spill.
Disconnect spark plug wire.
STORING FUEL OR EQUIPMENT WITH FUEL IN TANK
Store away from furnaces, stoves, water heaters, clothes
dryers, or other appliances that have pilot light or other
ignition source because they could ignite fuel vapors.
WARNING Starter cord kickback (rapid
retraction) will pull hand and arm toward
engine faster than you can let go which
could cause broken bones, fractures,
bruises, or sprains resulting in serious injury.
When starting engine, pull cord slowly until resistance is
felt and then pull rapidly to avoid kickback.
NEVER start or stop engine with electrical devices
plugged in and turned on.
7
NOTICE
Exceeding generators wattage/amperage
capacity could damage generator and/or electrical
devices connected to it.
DO NOT exceed the generator’s wattage/amperage
capacity. See Generator Capacity.
Start generator and let engine stabilize before connecting
electrical loads.
Connect electrical loads in OFF position, then turn ON for
operation.
Turn electrical loads OFF and disconnect from generator
before stopping generator.
NOTICE
Improper treatment of generator could
damage it and shorten its life.
Use generator only for intended uses.
If you have questions about intended use, ask dealer or
contact local service center.
Operate generator only on level surfaces.
DO NOT expose generator to excessive moisture, dust,
dirt, or corrosive vapors.
DO NOT insert any objects through cooling slots.
If connected devices overheat, turn them off and
disconnect them from generator.
Shut off generator if:
-electrical output is lost;
-equipment sparks, smokes, or emits flames;
-unit vibrates excessively.
WARNING Starter and other rotating parts
could entangle hands, hair, clothing, or
accessories resulting in serious injury.
NEVER operate generator without protective housing or
covers.
DO NOT wear loose clothing, jewelry or anything that
could be caught in the starter or other rotating parts.
Tie up long hair and remove jewelry.
CAUTION Excessively high operating speeds
could result in minor injury.
Excessively low operating speeds impose a heavy
load.
DO NOT tamper with governor spring, links or other parts
to increase engine speed. Generator supplies correct
rated frequency and voltage when running at governed
speed.
DO NOT modify generator in any way.
WARNING
Generator voltage could cause
electrical shock or burn resulting in death or
serious injury.
Use listed transfer equipment, suitable for the intended
use, to prevent backfeed by isolating generator from
electric utility workers.
When using generator for backup power, notify utility
company.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords which are
worn, frayed, bare or otherwise damaged.
DO NOT operate generator in the rain or wet weather.
DO NOT handle generator or electrical cords while
standing in water, while barefoot, or while hands or feet
are wet.
DO NOT allow unqualified persons or children to operate
or service generator.
WARNING Exhaust heat/gases could ignite
combustibles, structures or damage
fuel tank causing a fire, resulting in
death or serious injury.
Contact with muffler area could cause burns
resulting in serious injury.
DO NOT touch hot parts and AVOID hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 5 feet (1.5 m) of clearance on all sides of
generator including overhead.
It is a violation of California Public Resource Code,
Section 4442, to use or operate the engine on any forest-
covered, brush-covered, or grass-covered land unless
the exhaust system is equipped with a spark arrester, as
defined in Section 4442, maintained in effective working
order. Other states or federal jurisdictions may have
similar laws.
Contact the original equipment manufacturer, retailer, or
dealer to obtain a spark arrester designed for the exhaust
system installed on this engine.
Replacement parts must be the same and installed in the
same position as the original parts.
WARNING Unintentional sparking could cause
fire or electric shock resulting in
death or serious injury.
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR
GENERATOR
Disconnect the spark plug wire from the spark plug and
place the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
Use approved spark plug tester.
DO NOT check for spark with spark plug removed.
8 www.powerboss-equipment.com
Assembly
Your generator is ready for use after it has been
properly serviced with the recommended fuel and oil.
If you have any problems with the assembly of
your generator, please call the generator helpline
at (800) 743-4115. If calling for assistance, please
have the model, revision, and serial number from the
identification label available. See Generator Features
and Controls for identification label location.
Unpack Generator
1. Set the carton on a rigid, flat surface.
2. Remove everything from carton except generator.
3. Open carton completely by cutting each corner
from top to bottom.
4. Leave generator on carton to install wheel kit.
The generator is supplied with:
Operator’s manual
Engine oil bottle
NOTICE Be sure you have attached wheels and
support leg (if equipped) prior to adding oil and fuel.
Add Engine Oil
1. Place generator on a level surface.
2. Clean area around oil fill and remove yellow oil fill
cap/dipstick.
3. Using oil funnel (optional), slowly pour contents
of provided oil bottle into oil fill opening to the full
mark (A) on dipstick.
NOTICE
Improper treatment of generator could
damage it and shorten its life.
DO NOT attempt to crank or start the engine before it has
been properly serviced with the recommended oil. This
could result in an engine failure.
4. Replace oil fill cap/dipstick and fully tighten.
Add Fuel
Fuel must meet these requirements:
Clean, fresh, unleaded fuel.
A minimum of 87 octane/87 AKI (91 RON). For
high altitude use, see High Altitude.
Fuel with up to 10% ethanol (gasohol) is acceptable.
NOTICE Use of unapproved fuels could damage
generator and voids warranty.
DO NOT use unapproved fuel such as E15 and E85.
DO NOT mix oil in fuel or modify engine to run on alternate
fuels.
To protect the fuel system from gum formation, mix
in a fuel stabilizer when adding fuel. See Storage.
All fuel is not the same. If you experience starting or
performance problems after using fuel, switch to a
different fuel provider or change brands. This engine is
certified to operate on gasoline. The emission control
system for this engine is EM (Engine Modifications).
1. Clean area around fuel fill cap, remove cap.
2. Slowly add unleaded gasoline (B) to fuel tank (C).
Be careful not to fill above the baffle (D). This allows
adequate space for fuel expansion as shown.
3. Install fuel cap and let any spilled fuel evaporate
before starting engine.
High Altitude
At altitudes over 5,000 feet (1524 meters), a
minimum 85 octane / 85 AKI (89 RON) gasoline is
acceptable. To remain emissions compliant, high
altitude adjustment is required. Operation without
this adjustment will cause decreased performance,
increased fuel consumption, and increased emissions.
See a Briggs & Stratton Authorized Dealer for high
altitude adjustment information. Operation of the
engine at altitudes below 2,500 feet (762 meters) with
the high altitude kit is not recommended.
System Ground
The generator neutral is floating, which means that
the AC stator winding is isolated from the grounding
fastener and the AC receptacle ground pins. On a
floating neutral generator the AC receptacle ground
pins are not functional. Electrical devices, such as a
GFCI, requiring a functioning AC receptacle ground pin
will not operate.
FUEL
TANK
D
C
B
A
WARNING Fuel and its vapors are extremely
flammable and explosive which
could cause burns, fire or explosion
resulting in death or serious injury.
WHEN ADDING FUEL
Turn generator engine OFF and let it cool at least 2
minutes before removing fuel cap. Loosen cap slowly to
relieve pressure in tank.
Fill fuel tank outdoors.
DO NOT overfill tank. Allow space for fuel expansion.
If fuel spills, wait until it evaporates before starting engine.
Keep fuel away from sparks, open flames, pilot lights,
heat, and other ignition sources.
Check fuel lines, tank, cap and fittings frequently for
cracks or leaks. Replace if necessary.
DO NOT light a cigarette or smoke.
9
Special Requirements
There may be Federal, local codes, or ordinances that
apply to the intended use of the generator. Please
consult a qualified electrician, electrical inspector, or
the local agency having jurisdiction:
This generator is not intended to be used at a
construction site or similar activity as defined by NFPA
70-2014 (NEC) section 590.6.
Connecting to a Building’s Electrical System
Connections for standby power to a building’s electrical
system must be made by a qualified electrician. The
connection must isolate the generator power from utility
power or other alternative power sources and must
comply with all applicable laws and electrical codes.
Portable Generator Location
Before starting the portable generator there are two equally
important safety concerns regarding carbon monoxide
(CO) poisoning and fire that must be addressed.
Operation Location of Portable Generator to REDUCE
THE RISK OF CARBON MONOXIDE POISONING
All fossil fuel burning equipment, such as a portable
generator, contains carbon monoxide gas in the engine
exhaust, a poisonous gas that could kill you in minutes.
You CANNOT smell it, see it, or taste it. Even if you do
not smell exhaust fumes, you could still be exposed to
carbon monoxide gas. The following must be completed
prior to starting the portable generator engine:
• By law it is required in many states to have a
Carbon Monoxide alarm in operating condition
in your home. Install/maintain battery-operated
carbon monoxide alarms or plug-in carbon
monoxide alarms with battery back-up according to
the manufacturer’s instructions. A CO alarm is an
electronic device that detects hazardous levels of
CO. When there is a buildup of CO, the alarm will
alert the occupants by flashing visual indicator light
and alarm. Smoke alarms cannot detect CO gas.
WARNING
Generator voltage could cause
electrical shock or burn resulting in death or
serious injury.
Use approved transfer equipment to prevent backfeed by
isolating generator from electric utility workers.
When using generator for backup power, notify utility
company.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords which are
worn, frayed, bare or otherwise damaged.
DO NOT operate generator in the rain or wet weather.
DO NOT handle generator or electrical cords while
standing in water, while barefoot, or while hands or feet
are wet.
DO NOT allow unqualified persons or children to operate
or service generator.
Carbon
Monoxide
Alarm
10 www.powerboss-equipment.com
Operate this product ONLY outside far away from
windows, doors and vents to reduce the risk of
carbon monoxide gas from accumulating and
potentially being drawn towards occupied spaces.
DO NOT run this product inside homes, garages,
basements, crawlspaces, sheds, or other partially-
enclosed spaces even if using fans or opening
doors and windows for ventilation. Carbon
monoxide can quickly build up in these spaces
and can linger for hours, even after this product
has shut off.
Your neighbor(s) home may be exposed to the
engine exhaust from your portable generator and
must be considered when deciding on a location
for the safe operation of your portable generator.
ALWAYS place this product downwind and point
the engine exhaust away from occupied spaces.
If you start to feel sick, dizzy, or weak while using this
product, get to fresh air RIGHT AWAY. See a doctor. You
may have carbon monoxide poisoning.
Operation Location of Portable Generator to
REDUCE THE RISK OF FIRE
WARNING Exhaust heat/gases could ignite
combustibles, structures or damage fuel
tank causing a fire, resulting in death or
serious injury.
Portable generator must be at least 5 feet (1.5 m) from
any structure, overhang, trees, windows, doors, any wall
opening, shrubs, or vegetation over 12 inches (30.5 cm)
in height.
DO NOT place portable generator under a deck or other
type of structure that may confine airflow.
Smoke alarm(s) MUST be installed and maintained
indoors according to the manufacturer’s instructions/
recommendations. Carbon monoxide alarms cannot
detect smoke.
DO NOT place portable generator in manner other than
shown.
Install carbon monoxide alarms
inside your home. Without working
carbon monoxide alarms, you will
not realize you are getting sick
and dying from carbon monoxide.
CARBON MONOXIDE ALARM(S)
USE OUTDOORS - AVOID CARBON MONOXIDE POISONING
point away
from home
MUFFLER
EXAMPLE OF LOCATION TO
REDUCE THE RISK OF FIRE
5 ft.
(1.5 m) min.
5 ft. (1.5 m) min.
MUFFLER
11
Características y mandos
Read this Operator’s Manual and safety rules before operating your generator.
Compare the illustrations with your generator, to familiarize yourself with the locations of various controls
and adjustments. Save this manual for future reference.
A - Engine Switch — Set this switch to ON (I) before
using recoil starter. Set switch to OFF (0) to switch
off engine.
B - 120 Volt AC, 30 Amp RV Outlet (3500 Watt only)
May be used to supply electrical power for the
operation of 120 Volt AC, 30 Amp, single phase, 60
Hz electrical, travel trailer loads.
C - Main Breaker (3500 Watt only) — The receptacles
are provided with a main breaker to protect the
generator against electrical overload.
D - Oil Fill Cap/Dipstick — Check and add engine oil
here.
E - Oil Drain Plug — Drain engine oil here.
F - 120 Volt AC, 20 Amp, Duplex Receptacle
May be used to supply electrical power for the
operation of 120 Volt AC, 20 Amp, single phase,
60 Hz electrical, lighting, appliance, tool and motor
loads.
G - Circuit Breakers — The 120 Volt AC, 20A duplex
receptacles are provided with “push to reset” circuit
breakers to protect the generator against electrical
overload.
H - Grounding Fastener — Consult your local agency
having jurisdiction for grounding requirements in
your area.
J - Spark Arrester Muffler — Exhaust muffler lowers
engine noise and is equipped with a spark arrester
screen.
K - Air Cleaner — Protects engine by filtering dust
and debris out of intake air.
L - Choke Lever — Used when starting a cold engine.
M - Fuel Valve Used to turn fuel supply on and off to
engine.
N - Recoil Starter Used to start the engine manually.
P - Fuel Tank — Capacity of 3 U.S. gallons (11.4 l).
Items Not Shown:
Engine Identification — Provides model, type and
code of engine. Please have these readily available if
calling for assistance.
Identification Label (on back side of control panel) —
Provides model and serial number of generator. Please
have these readily available if calling for assistance.
G
L
H
M
C
B
A
P
N
D
E
F
K
J
12 www.powerboss-equipment.com
Cord Sets and Receptacles
Use only high quality, well-insulated, grounded
extension cords with the generator’s receptacles.
Inspect extension cords before each use.
Check the ratings of all extension cords before you
use them. Check operator’s manuals of devices to be
powered for the manufacturer’s recommendations.
120 Volt AC, 30 Amp RV Outlet (3500 Watt only)
Use a NEMA TT–30 plug with this receptacle. Connect
a 3–wire travel trailer cord set rated for 125 Volt AC
loads at 30 Amps to the plug.
Hot
120V
Ground
(Green)
NEMA
TT-30
Neutral
Use this receptacle to operate 120 Volt AC, 60 Hz,
single phase travel trailer loads requiring up to 3,500
watts (3.5 kW) of power at 29.1 Amps. The outlet is
protected by a push-to-reset circuit breaker.
NOTICE
Receptacles may be marked with rating
value greater than generator output capacity.
NEVER attempt to power a device requiring more
amperage than generator or receptacle can supply.
DO NOT overload the generator. See Generator Capacity.
120 Volt AC, 20 Amp, Duplex Receptacles
The duplex receptacles are protected against overload
by a push to reset circuit breaker.
Use receptacle to operate 120 Volt AC, single–phase,
60 Hz electrical loads requiring up to 2,400 watts
(2.4KW) at 20 Amps of current. Use cord sets that are
rated for 125 Volt AC loads at 20 Amps (or greater).
WARNING Damaged or overloaded electrical
cords could overheat, arc, and burn
resulting in death or serious injury.
ONLY use cords rated for your loads.
Follow all safeties on electrical cords.
Inspect cord sets before each use.
13
Operation
Starting the Engine
Disconnect all electrical loads from the generator. Use
the following start instructions:
1. Make sure unit is on a level surface.
NOTICE Failure to start and operate the unit on a
level surface could cause the unit not to start or shut
down during operation.
2. Turn the fuel valve (A) to ON (I) position.
A
3. Push choke lever (B) to CHOKE ( ) position.
4. Push engine switch (C) to the ON (I) position.
5. Grasp recoil handle and pull slowly until slight
resistance is felt. Then pull rapidly to start engine.
If engine starts, proceed to step 7.
If engine fails to start, proceed to step 6.
6. Move choke lever to CHOKE ( ) position, and
pull recoil handle twice.
If engine fails to start, repeat steps 5 thru 7.
7. Slowly move choke lever to RUN position (
). If
engine falters, move choke lever to half choke
position until engine runs smoothly, and then to
RUN position ( ).
NOTICE If engine floods, place choke lever in RUN
position ( ) and crank until engine starts.
NOTICE If engine starts after 3 pulls but fails to run,
or if unit shuts down during operation, make sure unit
is on a level surface and check for proper oil level in
crankcase. This unit may be equipped with a low oil
protection device. If so, oil must be at proper level for
engine to start.
Connecting Electrical Loads
1. Let engine stabilize and warm up for a few
minutes after starting.
2. Plug in and turn on the desired 120 Volt AC,
single phase, 60 Hz electrical loads.
NOTICE When plugging into the 120 Volt duplex
receptacles, plug items to be powered in sequence as
shown (3500 Watt ONLY).
NOTICE
DO NOT connect 240 Volt loads to the 120 Volt
duplex receptacles.
DO NOT connect 3-phase loads to the generator.
DO NOT connect 50 Hz loads to the generator.
DO NOT OVERLOAD THE GENERATOR. See
Generator Capacity.
C
B
WARNING Exhaust heat/gases could ignite
combustibles, structures or damage
fuel tank causing a fire, resulting in
death or serious injury.
Contact with muffler area could cause burns
resulting in serious injury.
DO NOT touch hot parts and AVOID hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 5 feet (1.5 m) of clearance on all sides of
generator including overhead.
It is a violation of California Public Resource Code,
Section 4442, to use or operate the engine on any forest-
covered, brush-covered, or grass-covered land unless
the exhaust system is equipped with a spark arrester, as
defined in Section 4442, maintained in effective working
order. Other states or federal jurisdictions may have
similar laws.
Contact the original equipment manufacturer, retailer, or
dealer to obtain a spark arrester designed for the exhaust
system installed on this engine.
Replacement parts must be the same and installed in the
same position as the original parts.
WARNING Starter cord kickback (rapid
retraction) will pull hand and arm toward
engine faster than you can let go which
could cause broken bones, fractures,
bruises, or sprains resulting in serious injury.
When starting engine, pull cord slowly until resistance is
felt and then pull rapidly to avoid kickback.
NEVER start or stop engine with electrical devices
plugged in and turned on.
1
3
2
4
14 www.powerboss-equipment.com
NOTICE
Exceeding generators wattage/amperage
capacity could damage generator and/or electrical
devices connected to it.
DO NOT exceed the generator’s wattage/amperage
capacity. See Generator Capacity.
Start generator and let engine stabilize before connecting
electrical loads.
Connect electrical loads in OFF position, then turn ON for
operation.
Turn electrical loads OFF and disconnect from generator
before stopping generator.
Stopping the Engine
1. Turn OFF and unplug all electrical loads from
generator panel receptacles. NEVER start or stop
engine with electrical devices plugged in and
turned ON.
2. Let engine run at no-load for several minutes
to stabilize internal temperatures of engine and
generator.
3. Push engine switch to the OFF (0) position.
4. Turn fuel valve lever to the OFF (0) position.
Low Oil Shutdown
If the engine oil drops below a preset level, an oil
switch will stop the engine or will not allow you to start
the engine. Make sure unit is on a level surface and
check oil level with dipstick.
If oil level is at FULL mark on dipstick:
1. DO NOT try to restart the engine.
2.
Contact an Authorized Briggs & Stratton Service Dealer.
3. DO NOT operate engine until oil level is corrected.
If oil level is below FULL mark on dipstick:
1. Add oil to bring level to FULL mark.
2. Restart engine and if the engine stops again a low
oil condition may still exist. DO NOT try to restart
the engine.
3. Contact an Authorized Briggs & Stratton Service
Dealer.
4. DO NOT operate engine until oil level is corrected.
WARNING Fuel and its vapors are extremely
flammable and explosive which
could cause burns, fire or explosion
resulting in death or serious injury.
DO NOT stop engine by moving choke handle to CHOKE
position
( ).
15
Generator Capacity
To make sure your generator can supply enough
running watts and starting watts for the items you will
power at the same time, follow these simple steps:
1. Select the items you will power at the same time.
See following list for typical wattages.
* Typical wattages listed are approximate only. Check
tool or appliance for actual wattage.
** Per Briggs & Stratton 628K, Starting Watts
represents the momentary electrical current the
generator can provide to start electric motors.
Starting Watts does not represent the power
required to continuously run electrical loads.
Starting Watts is the maximum current that can
momentarily be supplied when starting a motor,
multiplied by the generator’s rated voltage.
2. Total the running watts. This is the amount of
power your generator must produce to keep your
items running. See following example:
Example
Total running watts = 2355
Highest starting watts = 2000
Total generator watts required = 4355
3. Estimate the starting watts you will need. Because
not all motors start at the same time, total starting
wattage can be estimated by adding only the
item with the highest additional starting watts
requirements to the total running watts from step 2.
Power Management
To manage generator power, sequentially add loads as
follows:
1. With nothing connected to generator, start the
engine outdoors.
2. Plug in and turn on the first load, preferably the
largest load you have.
3. Permit the generator output to stabilize (engine
runs smoothly and attached device operates
properly).
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
Never add more loads than the generator capacity.
Take special care to consider surge loads in generator
capacity.
Tool or Appliance
Running
Watts*
Starting
Watts**
Light Bulb - 75 Watt 75 -
Sump Pump 800 1200
Refrigerator/Freezer 800 2000
Water Well Pump - 1/3 HP 1000 2000
Window AC - 10,000 BTU 1200 1800
Furnace Fan Blower - 1/2 HP 800 1300
Microwave Oven - 1000 Watt 1000 -
Color Television - 42” 280 -
Personal Computer w/17” monitor 800 -
Garage Door Opener - 1/2 HP 480 520
Tool or Appliance Running Watts Starting Watts
Window air conditioner
1200 1800
Refrigerator 800 2000
Television 280
Light (75 Watts) 75
2355 Total
Running Watts
2000 Highest
Starting Watts
16 www.powerboss-equipment.com
Maintenance
Maintenance Schedule
Follow the hourly or calendar intervals, whichever
occurs first. More frequent service is required when
operating in adverse conditions noted below.
First 5 Hours
Change engine oil
Every 8 Hours or Daily
Clean debris
Check engine oil level
Every 50 Hours or every season
Clean/Replace air filter
1
Every 100 Hours or every season
Change oil
1
Change/Adjust spark plug
Clean spark arrester
Service fuel valve
1
Service more often under dirty or dusty conditions.
General Recommendations
Regular maintenance will improve the performance
and extend the life of the generator. See any
authorized dealer for service.
The generator’s warranty does not cover items that have
been subjected to operator abuse or negligence. To
receive full value from the warranty, the operator must
maintain the generator as instructed in this manual.
NOTICE
Improper treatment of generator could
damage it and shorten its life.
NEVER operate generator without protective housing or
covers to assure proper cooling.
Some adjustments will need to be made periodically to
properly maintain your generator.
All service and adjustments should be made at least
once each season. A new spark plug and clean
air filter assure proper fuel-air mixture and help
your engine run better and last longer. Follow the
requirements in the Maintenance Schedule chart
above.
Emissions Control
Maintenance, replacement, or repair of the
emissions control devices and systems may
be performed by any non-road engine repair
establishment or individual. However, to obtain
”no charge” emissions control service, the work must
be performed by a factory authorized dealer. See the
Emissions Warranty.
Generator Maintenance
Generator maintenance consists of keeping the unit
clean and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture, or any corrosive vapors. Cooling
air slots in the generator must not become clogged
with snow, leaves, or any other foreign material.
NOTICE DO NOT use water or other liquids to clean
generator. Liquids can enter engine fuel system, causing
poor performance and/or failure to occur. In addition, if
liquid enters generator through cooling air slots, some of
the liquid will be retained in voids and cracks of the rotor
and stator winding insulation. Liquid and dirt buildup on
the generator internal windings will eventually decrease
the insulation resistance of these windings.
Cleaning
Daily or before use, look around and underneath
the generator for signs of oil or fuel leaks. Clean
accumulated debris from inside and outside the
generator. Keep the linkage, spring and other engine
controls clean. Keep the area around and behind
the muffler free from any combustible debris. Inspect
cooling air slots and openings on generator. These
openings must be kept clean and unobstructed.
Engine parts should be kept clean to reduce the risk of
overheating and ignition of accumulated debris:
Use a damp cloth to wipe exterior surfaces clean.
NOTICE
Improper treatment of generator could
damage it and shorten its life.
DO NOT expose generator to excessive moisture, dust,
dirt, or corrosive vapors.
DO NOT insert any objects through cooling slots.
Use a soft bristle brush to loosen caked on dirt or oil.
Use a vacuum cleaner to pick up loose dirt and
debris.
17
Fuel Valve Maintenance
The fuel valve is equipped with a fuel sediment cup,
screen, and o-ring that need to be cleaned.
1. Move fuel valve to OFF (0) position.
2. Remove sediment cup (A) from fuel valve.
Remove o-ring (B) and screen (C) from fuel valve.
A
B
C
3. Wash sediment cup, o-ring, and screen in a
nonflammable solvent. Dry them thoroughly.
4. Place screen and o-ring into fuel valve. Install
sediment cup and tighten securely.
5. Move fuel valve to ON (I) position, and check for
leaks. Replace fuel valve if there is any leakage.
Engine Maintenance
Oil
Oil Recommendations
We recommend the use of Briggs & Stratton Warranty
Certified oils for best performance. Other high-quality
detergent oils are acceptable if classified for service
SF, SG, SH, SJ or higher. DO NOT use special
additives.
Outdoor temperatures determine the proper oil
viscosity for the engine. Use the chart to select the
best viscosity for the outdoor temperature range
expected.
* Below 40°F (4°C) the use of SAE 30 will result in hard
starting.
** Above 80°F (27°C) the use of 10W30 may cause
increased oil consumption. Check oil level more frequently.
Checking Oil Level
Oil level should be checked prior to each use or
at least every 8 hours of operation. Keep oil level
maintained.
1. Make sure generator is on a level surface.
2. Clean area around oil fill, remove oil cap/dipstick
and wipe dipstick with clean cloth. Replace
dipstick. Remove and check oil level.
NOTICE DO NOT screw in dipstick when checking oil
level.
3. Verify oil is at full mark (D) on dipstick. Replace
and tighten oil cap/dipstick.
D
Adding Engine Oil
1. Make sure generator is on a level surface.
2. Check oil level as described in Checking Oil Level.
3. If needed, slowly pour oil into oil fill opening to the
full mark on dipstick. DO NOT overfill.
NOTICE Overfilling with oil could cause the engine
to not start, or hard starting.
DO NOT overfill.
If over the FULL mark on dipstick, drain oil to reduce oil
level to FULL mark on dipstick.
4. Replace and tighten oil cap/dipstick.
WARNING Unintentional sparking could cause
fire or electric shock resulting in
death or serious injury.
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR
GENERATOR
Disconnect the spark plug wire from the spark plug and
place the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
Use approved spark plug tester.
DO NOT check for spark with spark plug removed.
18 www.powerboss-equipment.com
Changing Engine Oil
If you are using your generator under extremely dirty or
dusty conditions, or in extremely hot weather, change
the oil more often.
KEEP OUT OF REACH OF CHILDREN.
DON’T POLLUTE. CONSERVE
RESOURCES. RETURN USED OIL TO
COLLECTION CENTERS.
Change the oil while the engine is still warm from
running, as follows:
1. Make sure unit is on a level surface.
2. Disconnect the spark plug wire from the spark
plug and place the wire where it cannot contact
spark plug.
3. Clean area around oil drain plug (A). The oil
drain plug is located at base of engine, opposite
carburetor.
4. Remove oil drain plug and drain oil completely
into a suitable container.
5. Reinstall oil drain plug and tighten securely.
Remove oil cap/dipstick.
6. Slowly pour recommended oil (about 20 oz.
(0.6 l)) into oil fill opening. Pause to permit oil to
settle. Fill to the full mark on dipstick.
7. Wipe dipstick clean each time oil level is checked.
DO NOT overfill.
8. Reinstall oil cap/dipstick. Tighten cap securely.
9. Wipe up any spilled oil.
Service Air Filter
Your engine will not run properly and may be damaged
if you run it with a dirty air filter. Clean or replace more
often if operating under dusty or dirty conditions.
To service the air filter, follow these steps:
1. Unclamp latches (B) that hold on the cover (C).
2. Remove cover and foam air filter (D).
3. Wash the foam air filter in liquid detergent and
water. Squeeze dry the foam air filter in a clean
cloth.
4. Saturate the foam air filter with clean engine oil.
To remove the excess engine oil, squeeze the
ffoam air filter in a clean cloth.
5. Reinstall clean or new foam air filter (D).
6. Reinstall the air filter cover and clamp latches.
Service Spark Plug
Changing spark plug will help your engine to start
easier and run better.
1. Clean area around spark plug.
2. Remove and inspect spark plug.
3. Replace spark plug if electrodes are pitted, burned
or porcelain is cracked. Use the recommended
replacement spark plug. See Specifications.
4. Check electrode gap with wire feeler gauge and
reset spark plug gap to recommended gap if
necessary (see Specifications).
5. Install spark plug and tighten firmly.
B
C
D
B
A
CAUTION Avoid prolonged or repeated skin
contact with used motor oil.
Used motor oil has been shown to cause skin cancer in
certain laboratory animals.
Thoroughly wash exposed areas with soap and water.
19
Inspect Muffler and Spark Arrester
Inspect the muffler for cracks, corrosion, or other
damage. Remove the spark arrester, if equipped, and
inspect for damage or carbon blockage. If replacement
parts are required, make sure to use only original
equipment replacement parts.
Clean or replace spark arrester as follows:
1. Allow the engine to cool completely before
servicing the spark arrester.
2. Remove the two screws (A) holding the cover plate
(B) which retains the end of the spark arrester (B)
to the muffler (D).
3. Remove the spark arrester screen.
4. Carefully remove the carbon deposits from the spark
arrester screen with a wire brush.
5. Replace the spark arrester if it is damaged.
6. Position the spark arrester in the muffler and
attach the cover plate with the two screws.
A
D
B
C
WARNING Exhaust heat/gases could ignite
combustibles, structures or damage
fuel tank causing a fire, resulting in
death or serious injury.
Contact with muffler area could cause burns
resulting in serious injury.
DO NOT touch hot parts and AVOID hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 5 feet (1.5 m) of clearance on all sides of
generator including overhead.
It is a violation of California Public Resource Code,
Section 4442, to use or operate the engine on any forest-
covered, brush-covered, or grass-covered land unless
the exhaust system is equipped with a spark arrester, as
defined in Section 4442, maintained in effective working
order. Other states or federal jurisdictions may have
similar laws.
Contact the original equipment manufacturer, retailer, or
dealer to obtain a spark arrester designed for the exhaust
system installed on this engine.
Replacement parts must be the same and installed in the
same position as the original parts.
20 www.powerboss-equipment.com
Storage
The generator should be started at least once every
seven days and allowed to run at least 30 minutes. If
this cannot be done and you must store the unit for
more than 30 days, use the following guidelines to
prepare it for storage.
Generator Storage
Clean the generator as outlined in Cleaning.
Check that cooling air slots and openings on
generator are open and unobstructed.
Long Term Storage Instructions
Fuel can become stale when stored over 30 days.
Stale fuel causes acid and gum deposits to form in the
fuel system or on essential carburetor parts. To keep
fuel fresh, use Briggs & Stratton® Advanced Formula
Fuel Treatment & Stabilizer, available wherever Briggs
& Stratton genuine service parts are sold.
There is no need to drain gasoline from the engine
if a fuel stabilizer is added according to instructions.
Run the engine for 2 minutes to circulate the stabilizer
hroughout the fuel system before storage.
If gasoline in the engine has not been treated with a
fuel stabilizer, it must be drained into an approved
container. Run the engine until it stops from lack
of fuel. The use of a fuel stabilizer in the storage
container is recommended to maintain freshness.
Change Engine Oil
While engine is still warm, drain oil from crankcase.
Refill with recommended grade. See Changing Engine
Oil.
Other Storage Tips
1. DO NOT store fuel from one season to another
unless it has been treated as described in Long
Term Storage Instructions.
2. Replace fuel container if it starts to rust. Rust and/
or dirt in fuel can cause problems if it’s used with
this unit.
3. Cover unit with a suitable protective cover that
does not retain moisture.
4. Store generator in clean, dry area.
WARNING Storage covers could cause a fire
resulting in death or serious injury
DO NOT place a storage cover over a hot generator.
Let equipment cool for a sufficient time before placing the
cover on the equipment.
WARNING Fuel and its vapors are extremely
flammable and explosive which
could cause burns, fire or explosion
resulting in death or serious injury.
WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN
TANK
Store away from furnaces, stoves, water heaters, clothes
dryers or other appliances that have pilot light or other
ignition source because they could ignite fuel vapors.
WHEN DRAINING FUEL
Turn generator engine OFF and let it cool at least 2
minutes before removing fuel cap. Loosen cap slowly to
relieve pressure in tank.
Drain fuel tank outdoors.
Keep fuel away from sparks, open flames, pilot lights,
heat, and other ignition sources.
Check fuel lines, tank, cap and fittings frequently for
cracks or leaks. Replace if necessary.
Do not light a cigarette or smoke.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72

Simplicity 030667-01 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur
Ce manuel convient également à