CONTENTS
Introduction Page 3
Getting started Page 4
Setting your programs Page 5
View and edit a schedule Page 8
Holiday mode Page 9
Energy monitor Page 10
Settings Page 12
Setting heating target Page 14
Advanced settings Page 15
Setting your heating system Page 16
Probes Page 17
Warranty Page 18
24/7 Technical hotline - Ligne d’assistance technique - Línea de asistencia técnica
US 1.888.927.6333 / CAN 1.888.592.7687
3
Your thermostat’s default screen is the Home Screen. This screen
displays important information such as the time, current floor and
air temperature as well as the target set temperature. From this page
you can either access the “MENU” page (press “menu”) or override
the current program (press “ ” or “ ”).
When using the 3IE thermostat there are some simple rules to keep
in mind:
1. Pressing “ ” allows you to confirm your selection
2. Pressing “ ” takes you back to a previous page in the menu
sequence
3. Pressing the “ ” and “ ” buttons allow you to change the
setting which is highlighted
4. Pressing an illuminated button in this group will allow you to highlight another setting to edit
5. Pressing an illuminated button in this group will allow you to select another option in the menu
6. When this light is illuminated it indicates that power is being directed to the heating systems (can be
turned off).
If you do not press any button on the thermostat for 1 minute, then it will go to standby mode. In standby
mode the screen will be dimmed but the thermostat will continue to function as normal. To exit standby
mode press “wake” ( ).
The button on bottom of the 3IE (button 7) is the power button. You can turn off your thermostat and
your Warmup floor heating system by holding down this button for 3 seconds. You can turn it on again by
holding it down for another 3 seconds.
INTRODUCTION
GROUND FAULT CIRCUIT INTERRUPTER
The GFCI feature is used to detect any leakage of current from your heating system. During a ground fault
the two lines of the load will be cut off. Once your thermostat is installed and connected to a power supply
you can test the GFCI function by increasing the set temperature until heating is on - the red light in the
top corner must be illuminated - and pressing the “TEST” button (see 8).
If your test is successful you will see the GROUND FAULT screen and you will need to hold “cancel” for 3
seconds in order to restore heating operation.
TE
ST
4
24/7 Technical hotline - Ligne d’assistance technique - Línea de asistencia técnica
US 1.888.927.6333 / CAN 1.888.592.7687
GETTING STARTED
1. Language
2. Time perefrences and settings
3. Date preference and settings
4. Daylight savings
5. Temperature preferences
6. Theme
7. Brightness
8. Standby Brightness
9. Heating LED
10. Audio Feedback
11. Floor type
12. Set heating target
13. Program schedule
14. Set energy monitor
15. (You may skip this section and
complete at a later date )
16. Energy settings
On initial power up the thermostat will guide you through set up procedure.
By accessing the main menu you can program your thermostat or make any changes to the thermostat
settings. To access the menu press “menu” on the main screen.
If the thermostat is in sleep mode press ”wake”.
LThe energy monitoring menu will be skipped automatically if a pre set program is selected on initial
setup.
GROUND FAULT CIRCUIT INTERRUPTER (contd)
However if the thermostat detects that one of the relays has FAILED to open correctly you will see the
Control Fault screen and the TEST LED will illuminate.
In the following circumstances you should immediately isolate the power supply to the thermostat and
contact Warmup customer service:
1. Press the TEST button when heating is on (the red light in the top corner is on) and the screen does
not display GROUND FAULT or cut power to the load.
2. The thermostat shows the GROUND FAULT screen during normal operation.
3. The thermostat shows the CONTROL FAULT screen.
Note: The GFCI test should be carried out monthly.
24/7 Technical hotline - Ligne d’assistance technique - Línea de asistencia técnica
US 1.888.927.6333 / CAN 1.888.592.7687
5
Press “ ” and “ ” to set the start time for the first of the
day.
If you want to change the target floor temperature press
“floor temp”, you can now press “up” and “down” to change
the target floor temperature.
If you want the target temperature to change later on in the
day then press “add another period”. You can add up to 10
periods in each day.
SETTING YOUR PROGRAM
Press “menu”, then Press “set program”.
You may have to press “wake” first, if the stat is in standby
mode.
Press the programming option that suits your needs.
• Set each day separately: set each day of the week with
a different program
• Set weekday and weekend: set a program for Monday –
Friday and a different program for Saturday and Sunday
• Set all days the same: one program is set for all the days
of the week
• Set fixed temperature: set a single temperature to be
held constantly
• Select a pre-set: see explanation in table
LIf you hold a button for several seconds it will scroll
continuously until you release your finger
72°F
next period
LIf you would rather use your thermostat to target
an air temperature then see page 12.
6
24/7 Technical hotline - Ligne d’assistance technique - Línea de asistencia técnica
US 1.888.927.6333 / CAN 1.888.592.7687
Once you have set all the desired periods in the day press
“OK” to go to the summary page.
This summary page allows you to see the program you have
set for this day. If you need to change something press
“edit”. This will take you back to the first period of the day.
Remember that you will need to add all the periods again.
If you are happy with the program and would like to set the
same program for the following day press “copy to …”
SETTING YOUR PROGRAM
LIt is recommended that you finish your daily program
on a low target temperature so that you save energy
overnight.
If you do not need the heating to protect against
frost then you can scroll down to the bottom of the
temperature range to set the target temperature to
“OFF”. With this setting the heating will not come on
regardless of the temperature.
If you are happy with the program but would like to set a
different program for the following day press “OK
If you would like to return to the preceding day press “back”.
When you have set a program for all the days including
Sunday (or Weekend in the case of Weekday/Weekend) then
pressing “OK” will enter the schedule and return you to the
home screen.
LThe set temperature for the time before the first
period of the day comes from the night before.
104 F
86
68
50
- oor
24/7 Technical hotline - Ligne d’assistance technique - Línea de asistencia técnica
US 1.888.927.6333 / CAN 1.888.592.7687
7
SETTING YOUR PROGRAM
If you are using your 3IE thermostat in the bathroom, bedroom, kitchen or living room then the pre-set
schedules might help you set a program appropriate for you. Just select the desired pre-set room and
everything is done automatically.
PRE-SET PROGRAMS TABLE :
Bathroom Kitchen Bedroom Living room
Time Floor Temp Time Floor Temp Time Floor Temp Time Floor Temp
Monday
to Friday
06:00 72°F/ 25°C 06:00 73°F / 23°C 06:00 72°F / 25°C
08:00 50°F / 10°C 08:00 50°F /10°C 08:00 50°F /10°C
19:00 68°F / 20°C 18:00 73°F / 23°C 20:00 68°F / 20°C 18:00 73°F / 23°C
23:00 59°F / 15°C 22:00 50°F /10°C 23:00 50°F / 10°C 21:30 50°F / 10°C
Saturday -
Sunday
07:00 72°F / 25°C 07:00 73°F/23°C 06:00 72°F / 25°C 08:00 73°F / 23°C
11:00 64°F / 18°C 11:00 64°F /18°C 08:00 50°F / 10°C
18:00 68°F / 20°C 18:00 73°F/ 23°C 20:00 68°F / 20°C 18:00 68°F / 20°C
23:00 59°F / 15°C 22:00 50°F /10°C 23:00 50°F / 10°C 20:00 50°F / 10°C
LIf you have used a pre-set schedule but want to make some changes just use the edit schedule
function explained in the “View and Edit a Schedule” section.
8
24/7 Technical hotline - Ligne d’assistance technique - Línea de asistencia técnica
US 1.888.927.6333 / CAN 1.888.592.7687
If you would like to view or edit the time and temperature
settings of each day then press “view / edit program”.
Press “up” and “down” until the day that you would like to
view is highlighted, then press “OK” to view that day.
To exit the “VIEW / EDIT PROGRAM” menu, press “back”.
Note that if you have edited any days these changes will be
saved.
Here you can see review the heating schedule for the
selected day.
If you would like to change any of the heating periods press
“edit”. Remember that you will have to set all the heating
periods. You can view the schedule for the following day by
pressing “view …”.
To return to the day selection, press “OK”.
VIEW AND EDIT A SCHEDULE
L If you want to change the settings of multiple days it
might be easier to set a new program using the “set
program” option
104 F
86
68
50
24/7 Technical hotline - Ligne d’assistance technique - Línea de asistencia técnica
US 1.888.927.6333 / CAN 1.888.592.7687
9
HOLIDAY MODE allows you to over-ride your schedule with
a fixed temperature for a prolonged period of time. This
can help save energy if you know that you will be out of the
house and only want minimal heating.
Press the highlighted button next to “holiday”.
Press “up” and “down” to set the first day you would like the
HOLIDAY MODE to start.
Press “holiday end at” and then press “up” and “down” to
set the day when you would like holiday mode to stop. At
the end of the HOLIDAY MODE your program will return to
the current settings. If you would like HOLIDAY MODE to
continue indefinitely, leave the end date on “not specified”.
Press “holiday temperature” to set the fixed temperature
that will be held for the entire HOLIDAY MODE period.
Pressing “OK” will confirm the selection and HOLIDAY MODE
will start at 12:00 pm on the specified date.
During the HOLIDAY MODE you will have a modified home
screen. To cancel the HOLIDAY MODE at any time just press
“cancel”.
If you want to return to HOLIDAY MODE you will need to set
it again.
HOLIDAY MODE
5
5F
2011
50 F
F
10
24/7 Technical hotline - Ligne d’assistance technique - Línea de asistencia técnica
US 1.888.927.6333 / CAN 1.888.592.7687
ENERGY MONITOR
Your thermostat monitors the amount of energy your floor
heating system is using, you can use these pages to view the
amount of energy used and set parameters to estimate the
cost of that energy.
If you want to see how much energy you have used then
select “view energy use” and then select the time period you
would like to review.
* If you see the “load settings” option you will need to enter
the total power in watts of the floor heating system connect
to the thermostat. If you are unclear about the power of your
floor heating then contact your installer.
After you press “view energy use”, you will need to select the
length of time in which you are interested.
On the graph each red bar indicates a time period (in this
case it is months). The height of the bar indicates that
amount of energy in KWH used by the floor heating system
during that period. The bar in the far right is the most recent
time period and the bar on the far left is the oldest.
The total amount of energy used in the entire time span is
displayed in the bottom bar.
Press “OK” to return to the ENERGY MONITOR menu.
L If you are interested in seeing how much energy you
can save by adjusting the settings of your thermostat,
then alter your heating program and wait a few days
before comparing the daily energy used before and
after you changed your program.
24/7 Technical hotline - Ligne d’assistance technique - Línea de asistencia técnica
US 1.888.927.6333 / CAN 1.888.592.7687
11
$
ENERGY MONITOR
If you want to view the estimated cost of your energy usage
then you will need to set the cost parameters in “energy
settings”. The cost estimate will only be accurate for the time
period AFTER you set the heating costs.
• Single energy tariff means that you have a single cost
of electricity all day long
• Standard / low energy tariff means that you have a
discounted cost of electricity during part of the day.
Select the appropriate structure that applies to your
electricity tariff plan.
For both the standard and low energy tariff you will need
to set a cost per Kilowatt hour (KWH). First set the relevant
currency by pressing “up” and “down” (you can select £, $,
and Y). Press “ok” to proceed to the first digit of the energy
tariff, press “up” and “down” to select the correct amount
and then press “ok” to proceed to the second digit. Continue
pressing “ok” until you have set all the digits and returned to
the ENERGY MONITOR main page.
If you are setting a “standard/ low energy tariff” you will also
need to set the time of day at which the low energy tariff
starts and stops and the cost per KWH during the low tariff
period.
After all these parameters are set you can view the cost of
the energy used by your floor heating system in “view cost
estimate”. If you are using “standard / low energy tariff”
then the amount/ cost of energy used in the standard period
will be displayed in red and the amount/ cost used in the low
period will be displayed in white.
L If your energy cost is 11.6 cents per KWH then you will
need to set it to $0.116.
12
24/7 Technical hotline - Ligne d’assistance technique - Línea de asistencia técnica
US 1.888.927.6333 / CAN 1.888.592.7687
Your 3IE is a very flexible device and be configured in many
different ways to meet your requirements.
Functions that can be accessed in the “settings” menu
include:
Time
• Settimeanddate
• Set time format preference (12Hr clock or 24Hr
clock and date format preference (MM/DD/YYYY or
DD/MM/YYY)
• Turnonautomaticday-lightsavingsforyourregion
Language
• Selectthelanguageofoperations
Temperature preferences
• Selecttemperatureunitpreference(°Cor°F)
Display / audio
• Choosehomescreenthemeandsetscreenbrightness
• Turnon/offheatingLEDandaudiofeedback
• Turnon/offchildlock(detailsontheoppositepage)
Set heating target
• Select if your thermostat uses floor temperature
sensor or air temperature sensor for thermal regulation
(details : see page 14)
Advanced settings
WARNING!! The options in this section can affect the
performance of your thermostat and should only be
modified by an experienced floor heating installer or
under the instruction of Warmup technical support.
SETTINGS
24/7 Technical hotline - Ligne d’assistance technique - Línea de asistencia técnica
US 1.888.927.6333 / CAN 1.888.592.7687
13
SETTINGS
Theme
• Change the content and style of home screen and
standby screen
Standby brightness
• Setthe brightness of the LCDscreeninstandbymode
between 0 (dimmest) and 5 (brightest)
Note: when set to 0 the LCD screen will turn OFF and
the “wake” LED will not be illuminated. You will need to
remember that you turn the screen on by pressing
Display brightness
• SetthebrightnessoftheLCDscreeninnormaloperation
between 1 (dimmest) and 6 (brightest)
Heating indication
• Thisfeatureallowsyoutoturnofftheheatingindication
LED (top right of the LCD screen). The thermostat will
continue to operate as normal but the LED will not turn
on to indicate when heating has started and stopped.
Audio feedback
• Thisfeatureallowsyoutoturnoffthebeepsoundmade
when a button is pressed
Child lock
• Childlockcreatesadelaybetweenpressing“wake”and
exiting the standby mode. When child lock is on you will
need to hold “wake” continuously for 10 seconds in order
to exit standby mode.
14
24/7 Technical hotline - Ligne d’assistance technique - Línea de asistencia técnica
US 1.888.927.6333 / CAN 1.888.592.7687
Your thermostat is capable of using a floor temperature
sensor, air temperature sensor or both for thermal regulation.
If you are using your floor heating as secondary heating
source (such as in the bathroom) then you might prefer to
use the floor temperature. However if the floor heating is the
primary heating source in your home you might prefer to use
the air temperature.
Set floor temperature
• The thermostat will use the temperature reading from
the floor sensor to decide whether heating is required to
achieve the target set temperature
Set floor temperature with air limit
• Thermostat will use the temperature reading from the
floor sensor to decide whether heating is required to
achieve the target set temperature, however if the air
temperature goes above the set limit then heating will
be suspended until air temperature falls below limit.
Set air temperature
• Thermostat will use the temperature reading from
the air sensor (inside thermostat housing) to decide
whether heating is required to achieve the target set
temperature.
SETTING HEATING TARGET
Start
L Hint: if you change the heating target settings then it is
advisable to re-program your thermostat to ensure that
the program still meets your needs
24/7 Technical hotline - Ligne d’assistance technique - Línea de asistencia técnica
US 1.888.927.6333 / CAN 1.888.592.7687
15
WARNING!!
The options in this section can affect the performance of your thermostat and should only be modified by
an experienced floor heating installer or under the instruction of Warmup technical support.
ADVANCED SETTINGS
Programmable Limit Overheat
Limit
Air Floor
Min Max Min Max
Tiles 41°F / 5°C 86°F / 30°C 41°F / 5°C 104°F / 40°C 104°F / 40°C
Stone 41°F / 5°C 86°F / 30°C 41°F / 5°C 104°F / 40°C 104°F / 40°C
Laminate 41°F / 5°C 81°F / 27°C 41°F / 5°C 81°F / 27°C 86°F / 30°C
Wood 41°F / 5°C 81°F / 27°C 41°F / 5°C 81°F / 27°C 86°F / 30°C
Carpet 41°F / 5°C 81°F / 27°C 41°F / 5°C 81°F / 27°C 86°F / 30°C
Vinyl 41°F / 5°C 81°F / 27°C 41°F / 5°C 81°F / 27°C 86°F / 30°C
User Defined User Defined User Defined User Defined
16
24/7 Technical hotline - Ligne d’assistance technique - Línea de asistencia técnica
US 1.888.927.6333 / CAN 1.888.592.7687
SETTING YOUR HEATING SYSTEM
Floor type
This setting will affect the upper and lower limits of
programmable set temperatures as well as the overheat limit.
If you set a user defined limit then you are advised to check
the safe temperature limits with the flooring manufacturer
Master/ relay
This feature allows you to use one thermostat to control
another. This is useful if you need to control multiple floor
heating elements with one program. In order to set-up this
feature use the following steps:
1. Choose which thermostat will be the “master” and
which will be the “relay”.
2. Use low voltage electric cable to connect terminal 3 on
the “master” to terminal 3 on the “relay”.
3. Use low voltage electric cable to connect terminal 2 on
the “master” to terminal 2 on the “relay”.
4. In advanced settings of each thermostat switch the
“master” thermostat to master mode and the “relay”
thermostat to relay mode.
5. Program desired schedule into the “master”
thermostat. The “relay” thermostat will no longer use
its sensors for thermal regulation. It will now turn on/
off in tandem with the “master” thermostat.
LOn the “master” thermostat these connector cables
are in addition to the floor sensor but on the “relay”
thermostat the floor sensor is not necessary.
953
AM
953
AM
09:32 tues 23 jul 09
21.0°c target
20.5°c
floor
16.5°c out
16.5°c out
19.0°c air
19.0°c air
wake
tues 23 jul 09
21.0°c target
20.5°c
floor
14:22
wake
program
holiday
mode
advanced
sengs
energy
monitor
sengs
OPTIONS
ok
program
holiday
mode
advanced
sengs
energy
monitor
sengs
period: 1
day: all
add another
period
start me
08:00
floor temp
22.0°C
air limit temp
22.0°C
PROGRAM
ok cancel
SUMMARY all days
ok cancel - air
- floor - air
- floor
COST july
ok
0
1
2 £
std = £10.54 : low = £16.28
std = £10.54 : low = £16.28
LANGUAGE
english
francais
deutsch
espanol
portugese
cancel up downok
09:32 tues 23 jul 09
20.5°c
floor
temporary override
unl 20:00
cancel
21.0°c target
MASTER/RELAY
off
master
relay
19.0°c floor
19.0°c floor
21.5°c target
21.5°c target
19.0°c floor
19.0°c floor
21.5°c target
21.5°c target
wake
tues 23 jul 11
ok
OPTIONS tues 23 jul 09
21.0°c target
20.5°c
floor
21.0°c target
20.5°c
floor
09:32 tues 23 jul 09
09:32 tues 23 jul 09
16.5°c out
19.0°c air
19.0°c air
16.5°c out
16.5°c out
19.0°c air
19.0°c air
16.5°c out
16.5°c out
19.0°c air
19.0°c air
tues 23 jul 09
wake
09:32 tues 23 jul 09
wake
16.5°c out
16.5°c out
19.0°c air
19.0°c air
14:22
14:22
wakewake
19.0°c floor
19.0°c floor
21.5°c target
21.5°c target
16.5°c out
16.5°c out
19.0°c air
19.0°c air
19.0°c floor
19.0°c floor
21.5°c target
21.5°c target
16.5°c out
16.5°c out
19.0°c air
19.0°c air
wake
hours
0 12 24
10
20
30
40°C
program
holiday
mode
advanced
sengs
energy
monitor
sengs
OPTIONS tues 23 jul 09
09:32 tues 23 jul 11
72°F target
60.0°F out
60.0°F out
66.0°F air
66.0°F air
wake
09:32 tues 23 jul 11
wake
cancel up downok
24/7 Technical hotline - Ligne d’assistance technique - Línea de asistencia técnica
US 1.888.927.6333 / CAN 1.888.592.7687
17
Reset
PROBES
External sensor
You are able to attach a second sensor to terminals 2 and 3.
You can then use external sensor function to define the use of
that sensor:
1. External sensor: This is to be used when you can locate
the external sensor outside of the heated environment.
When this setting is selected it will display the external
temperature on the home screen and engage weather
compensation. Weather compensation saves energy by
delaying the start of heating period by 10 minutes if the
difference between internal and external temperature is
less than 41°F.
2. 2nd floor sensor: This is to be used if the floor surface area is very large and delicate to overheating.
The reading from this secondary floor sensor will be used to monitor the overheat limit.
Probe specification
If you have already installed a sensor which was not supplied by Warmup then you can use this setting to
allow your thermostat to function. The possible options are NTC 10K (standard probe supplied by Warmup
with the 3IE), NTC 12K (probe supplied by Warmup with previous models of thermostat) and NTC 15K. Note
that all thermostats are different and Warmup can only validate the thermostat’s performance when used
with a Warmup probe supplied for use with the 3IE.
Offset
In order to improve temperature reading accuracy this feature allows you to bias each sensor’s temperature
reading up or down by 41°F.
Reset
Reset will restore all software settings to the factory specified defaults.
LIf you are experiencing problems with your thermostat then you can perform a system reset by
holding the button the rear of the front module for 10 seconds.
18
24/7 Technical hotline - Ligne d’assistance technique - Línea de asistencia técnica
US 1.888.927.6333 / CAN 1.888.592.7687
WARRANTY
Warmup Inc warrants this product, to be free from defects in
the workmanship or materials, under normal use and service,
for a period of three (3) years from the date of purchase by
the consumer. If at any time during the warranty period the
product is determined to be defective, Warmup shall repair
or replace it, at Warmup’s option.
If the product is defective, please either,
(I) return it, with a bill of sale or other dated proof of
purchase, to the place from which you purchased it, or
(ii) contact Warmup. Warmup will determine whether the
product should be returned, or replaced.
This warranty does not cover removal or reinstallation costs,
and shall not apply if it is shown by Warmup that the defect
or malfunction was caused by damage which occurred while
the product was in the possession of a consumer.
Warmup’s sole responsibility shall be to repair or replace the
product within the terms stated above.
WARMUP SHALL NOT BE LIABLE FOR ANY LOSS OR
DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR
CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR
INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY,
EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS
PRODUCT. THIS WARRANTY IS THE ONLY EXPRESS
WARRANTY WARMUP MAKES ON THIS PRODUCT. THE
DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-
YEAR DURATION OF THIS WARRANTY.
This Warranty does not affect your statutory rights.
PLEASE REGISTER YOUR WARMUP PRODUCT AT:
www.warmup.com / www.warmup.ca
INSTALLATION
GUARANTEE
TM
24/7 Technical hotline - Ligne d’assistance technique - Línea de asistencia técnica
US 1.888.927.6333 / CAN 1.888.592.7687
19
CONTENU
Introduction Page 20
Premiers pas Page 21
Configuration des programmes Page 22
Programmes pré-définis Page 24
Voir et éditer un programme Page 25
Mode vacances Page 26
Contrôle de l’énergie Page 27
Réglages Page 29
Configurer la température cible Page 31
Paramètres avancés Page 32
Régler votre système chauffant Page 33
Sondes Page 34
Garantie Page 35
20
24/7 Technical hotline - Ligne d’assistance technique - Línea de asistencia técnica
US 1.888.927.6333 / CAN 1.888.592.7687
Lors de votre première utilisation du thermostat 3iE™,
familiarisez-vous avec ses six zones tactiles et son indicateur
LED lumineuse. Ils vont permettront de régler votre
thermostat et d’en modifier les paramètres. Les contrôles de
base sont les suivants :
1. La touche vous permet de valider une sélection.
2. Appuyez sur la touche pour annuler un réglage ou
pour retourner à l’écran précédent.
3. Grâce aux touches et vous pourrez augmenter et
diminuer les valeurs et/ou données.
4 et 5. Ces touches luminescentes vous permettent de
sélectionner l’option ou le paramètre que vous souhaitez
éditer.
6. Cette diode s’allume lorsque le système est en marche
ou actif.
7. Au bas de la façade du thermostat se trouve le bouton
d’alimentation. Pour mettre en marche ou éteindre
complètement le thermostat il suffit de presser ce
bouton pendant 3 secondes.
En outre, vous pouvez l’utiliser pour revenir à l’écran
d’accueil á tout moment.
Après une minute d’inactivité, l’écran du thermostat
s’assombrit puis se met en veille. En mode veille, le
thermostat continue de fonctionner normalement. Pour
désactiver ce mode, appuyez sur la touche “actif” ( ).
Sur l’écran d’accueil de votre thermostat, vous pourrez lire
des informations importantes telles que la date, l’heure, les
températures du sol et de l’air et aussi la température désirée.
A partir de cet écran, vous pouvez soit accéder au menu (en
appuyant sur “MENU”), soit passer outre le programme en
cours (en apputant sur “ “ ou “ “).
INTRODUCTION
LDans plusieurs des menus, vous trouverez l’option “aide”. Sélectionnez-la pour obtenir des
explications plus detaillées ou plus d’informations sur certaines fonctionnalités.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Warmup 3iE Energy Monitoring Thermostat Manuel utilisateur

Catégorie
Thermostats
Taper
Manuel utilisateur

dans d''autres langues