WARNING RISK OF FIRE
To reduce the risk of severe injury or death, follow all installation instructions.
&ORWKHVGU\HULQVWDOODWLRQPXVWEHSHUIRUPHGE\DTXDOL¿HGLQVWDOOHU
Install the clothes dryer according to these instructions and in accordance with local
codes. In the absence of local codes, installation must comply with National Fuel Gas
Code, ANSIZ223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation
Code, CSA B149.1.
California Safe Drinking Water and Toxic Enforcement Act.
This act requires the governor of California to publish a list of substances known to
the state to cause cancer, birth defects or other reproductive harm and requires
businesses to warn customers of potential exposure to such substances. Gas
appliances can cause minor exposure to four of these substances, namely benzene,
carbon monoxide, formaldehyde and soot, caused primarily by the incomplete
combustion of natural gas or LP fuels. Properly adjusted dryers will minimize
incomplete combustion. Exposure to these substances can be minimized further by
properly venting the dryer to the outdoors.
This dryer must be exhausted to the outdoors.
Use only 4” rigid metal ducting for exhausting the clothes dryer to the outdoors.
DO NOTLQVWDOODFORWKHVGU\HUZLWKÀH[LEOHSODVWLFGXFWLQJPDWHULDOV,IÀH[LEOHPHWDO
(semi-rigid or foil-type) duct is installed, it must be UL listed and installed in accordance
with the instructions found in “Connecting The Dryer To House Vent” on page 6 of this
manual. Flexible venting materials are known to collapse, be easily crushed, and trap
OLQW7KHVHFRQGLWLRQVZLOOREVWUXFWGU\HUDLUÀRZDQGLQFUHDVHWKHULVNRI¿UH
Do not install or store this appliance in any location where it could be exposed to
water and or weather.
Save these instructions. (Installers: Be sure to leave these instructions with the
customer).
In the state of Massachusetts:
,QVWDOODWLRQ PXVW EH SHUIRUPHG E\ D TXDOL¿HG RU OLFHQVHG FRQWUDFWRU
SOXPEHURUJDV¿WWHUTXDOL¿HGRUOLFHQVHGE\WKHVWDWH
:KHQXVLQJEDOOW\SHJDVVKXWRȹYDOYHVWKH\VKDOOEH7KDQGOHW\SH
$ÀH[LEOHJDVFRQQHFWRUZKHQXVHGPXVWQRWH[FHHGIHHW
Installation
Instructions
Gas Dryer
01
BEFORE YOU BEGIN
Read these instructions completely and
FDUHIXOO\
,03257$17 Save these instructions
for local inspector’s use.
,03257$17 Observe all governing
codes and ordinances.
1RWHWR,QVWDOOHU Be sure to leave these
instructions with the customer.
1RWH WR &XVWRPHU Keep these
instructions with your Owner’s Manual for
future reference.
Before the old dryer is removed from
service or discarded, remove the dryer
door.
Inspect the dryer exhaust outlet and
straighten the outlet walls if they are bent.
Service information and the wiring
diagram are located in the control console.
Do not allow children on or in the appliance.
Close supervision of children is necessary
when the appliance is used near children.
Install the dryer where the temperature is
above 50°F for satisfactory operation of
the dryer control system.
Product failure due to improper installation
is not covered under the Warranty.
LEVEL
8" PIPE WRENCH
10" ADJUSTABLE WRENCHES
(x2)
SLIP JOINT PLIERS
FLAT BLADE SCREWDRIVER
M ATERIALS YOU WILL NEED
EXHAUST HOOD
FLEXIBLE GAS LINE CONNECTOR
SOAP SOLUTION
FOR LEAK DETECTION
PIPE
COMPOUND
DUCT TAPE
GLOVES
SAFETY GLASSES
4" DIAM METAL ELBOW
4" DUCT CLAMPS
OR
4" SPRING CLAMPS
(x2)
(x2)
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT
(IF NEEDED.)
234D2217P001 31-16735 10-13 GE
D
E
S
I
G
N
C
E
R
T
I
F
I
E
D
4XHVWLRQV"&DOO*(&$5(6RUYLVLWRXU:HEVLWHDW*($SSOLDQFHVFRP
,Q&DQDGDFDOORUYLVLWZZZ*($SSOLDQFHVFD
TOOLS YOU WILL
NEED
Installation Instructions
2
0LQLPXP&OHDUDQFH2WKHU7KDQ$OFRYHRU&ORVHW,QVWDOODWLRQ
Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear.
Consideration must be given to provide adequate clearance for installation and service.
GAS REQUIREMENTS
WARNING
• Installation must conform to local codes and
RUGLQDQFHVRULQWKHLUDEVHQFHWKH1$7,21$/)8(/
*$6&2'($16,=
 7KLV JDV GU\HU LV HTXLSSHG ZLWK D 9DOYH  %XUQHU
$VVHPEO\ IRU XVH RQO\ ZLWK QDWXUDO JDV 8VLQJ
FRQYHUVLRQ NLW :(; \RXU ORFDO VHUYLFH
RUJDQL]DWLRQ FDQ FRQYHUW WKLV GU\HU IRU XVH ZLWK
SURSDQH/3JDV$//&219(56,2160867%(0$'(
BY PROPERLY TRAINED AND QUALIFIED PERSONNEL
AND IN ACCORDANCE WITH LOCAL CODES AND
25',1$1&(5(48,5(0(176
7KHGU\HUPXVWEHGLVFRQQHFWHGIURPWKHJDVVXSSO\
SLSLQJ V\VWHP GXULQJ DQ\ SUHVVXUH WHVWLQJ RI WKDW
V\VWHPDWDWHVWSUHVVXUHLQH[FHVVRI36,.3D
7KHGU\HUPXVWEHLVRODWHGIURPWKHJDVVXSSO\SLSLQJ
V\VWHP E\ FORVLQJ WKH HTXLSPHQW VKXWRȹ YDOYH
GXULQJDQ\SUHVVXUHWHVWLQJRIWKHJDVVXSSO\SLSLQJ
RIWHVWSUHVVXUHHTXDOWRRUOHVVWKDQ36,.3D
GAS SUPPLY
• A 1/8-in.National Pipe Taper thread plugged tapping,
accessible for test gauge connection, must be installed
immediately upstream of the gas supply connection to
the dryer. Contact your local gas utility should you have
questions on the installation of the plugged tapping.
Supply line is to be 1/2-in. rigid pipe and equipped with
DQDFFHVVLEOHVKXWRȺZLWKLQ IWRIDQG LQ WKHVDPH
room with the dryer.
 8VH SLSH WKUHDG VHDOHU FRPSRXQG RU 7HÀRQ WDSH
appropriate for natural or LP gas.
 <RXPXVWXVHZLWKWKLVGU\HUDÀH[LEOHPHWDOFRQQHFWRU
listed connector ANSI Z21.24 / CSA 6.10. The length of
the connect shall not exceed 3 ft.
 &RQQHFWÀH[LEOHPHWDOFRQQHFWRUWRGU\HUDQGJDVVXSSO\
 2SHQVKXWRȺYDOYH
INTERNAL DUCT
OPENING
CHECK THAT EXHAUST
HOOD DAMPER OPENS
AND CLOSES FREELY.
WALL
TILT THE DRYER SIDEWAYS
AND REMOVE THE FOAM
SHIPPING PADS BY
PULLING AT THE SIDES
AND BREAKING THEM
AWAY FROM THE DRYER
LEGS. BE SURE TO
REMOVE ALL OF THE
FOAM PIECES AROUND
THE LEGS.
1
PREPARING FOR INSTALLATION OF
NEW DRYER
7,3,QVWDOO\RXUGU\HUEHIRUHLQVWDOOLQJ\RXUZDVKHU
7KLVZLOODOORZEHWWHUDFFHVVZKHQLQVWDOOLQJGU\HU
H[KDXVW
DISCONNECTING GAS
5(029,1*/,17)520:$//(;+$867
OPENING
5HPRYHDQGGLVFDUGH[LVWLQJSODVWLFRUPHWDOIRLO
WUDQVLWLRQGXFWDQGUHSODFHZLWK8/OLVWHGWUDQVLWLRQ
GXFW
DISCONNECT AND DISCARD OLD
FLEXIBLE GAS CONNECTOR AND
OLD TRANSITION DUCTING
MATERIAL. REPLACE WITH NEW
CSA(AGA) APPROVED FLEXIBLE
GAS LINE CONNECTOR AND UL
APPROVED TRANSITION DUCT.
TURN GAS
SHUT-OFF VALVE
TO THE OFF
POSITION.
:$51,1*1(9(55(86(2/'
)/(;,%/(&211(&7256
7KHXVHRIROGÀH[LEOHFRQQHFWRUVFDQFDXVHOHDNVDQG
SHUVRQDOLQMXU\ $OZD\VXVH QHZÀH[LEOH FRQQHFWRUV
when installing gas appliances.
DRYER GAS SUPPLY CONNECTION
2"
2-5/8"
3/8" NPT MALE THREAD GAS SUPPLY
NOTE: Add to vertical dimension
the distance between cabinet
bottom to floor.
Gas clothes dryers input ratings are based on sea level
operation and need not be adjusted for operation at or
below 2000 ft. elevation.
For operation at elevations above 2000 ft., input ratings
should be reduced at a rate of 4 percent for each 1000
ft. above sea level.
• Installation must conform to local codes and ordinances or,
in their absence, the NATIONAL FUEL GAS CODE, ANSI Z223.
$'-867,1*)25(/(9$7,21
Installation Instructions
3
LEAK TEST
RECONNECTING GAS
Note:7KHFRQQHFWRUDQG¿WWLQJVDUHGHVLJQHGIRUXVH
only on the original installation and are not to be reused
IRUDQRWKHUDSSOLDQFHRUDWDQRWKHUORFDWLRQ.HHSÀDUH
end of adaptor free of grease, oil and thread sealant.
CAUTION: Use adapters as shown. Connector
nuts must not be connected directly to pipe threads.
WARNING: 1(9(586($123(1
)/$0(727(67)25*$6/($.6
FLARE
NPT
PIPE SIZE
Listed connector ANSI Z21.24
/
CSA 6.10
1/8" NPT PIPE
PLUG FOR
CHECKING GAS
INLET PRESSURE
AT LEAST 1/2"
3/8" NPT
TIGHTEN THE FLEXIBLE
GAS LINE USING TWO
ADJUSTABLE WRENCHES.
TIGHTEN ALL CONNECTIONS
USING TWO ADJUSTABLE WRENCHES.
DO NOT OVERTORQUE GAS CONNECTIONS!
e
ck all connections for leaks with soapy solution or equivalent.
p
ly soap solution. Leak test solution must not contain ammonia
ch could cause damage to the brass fittings. If leaks are found,
s
e valve, retighten the joint, and repeat the soap test.
Installation Instructions
4
ELECTRICAL CONNECTION
INFORMATION
ELECTRICAL REQUIREMENTS
This appliance must be supplied with 120V, 60Hz, and
connected to a properly grounded branch circuit,
protected by a 15- or 20- amp circuit breaker or time-
delay fuse. If electrical supply provided does not meet the
DERYH VSHFL¿FDWLRQV LW LV UHFRPPHQGHG WKDW D OLFHQVHG
electrician install an approved outlet.
:$51,1*TO REDUCE THE
5,6.2)),5((/(&75,&$/6+2&.
AND PERSONAL INJURY:
'212786($1(;7(16,21&25'25$1$'$37(5
3/8*:,7+7+,6$33/,$1&(
Dryer must be electrically grounded in accordance
with local codes and ordinances, or in the absence
of local codes, in accordance with the NATIONAL
ELECTRICAL CODE, ANSI/NFPA NO. 70.
:$51,1* THIS DRYER IS
(48,33(' $ 7+5((3521* *5281',1*
PLUG FOR YOUR PROTECTION AGAINST
6+2&.+$=$5'$1'6+28/'%(3/8**('
DIRECTLY INTO A PROPERLY GROUNDED
7+5((3521* 5(&(37$&/( '2 127 &87
25 5(029( 7+( *5281',1* 3521*
)5207+,63/8*
ENSURE PROPER GROUND
EXISTS BEFORE USE.
IF LOCAL CODES PERMIT,
AN EXTERNAL GROUND WIRE
(NOT PROVIDED), WHICH MEETS
LOCAL CODES, MAY BE ADDED
BY ATTACHING TO THE GREEN
GROUND SCREW ON THE REAR
OF THE DRYER, AND TO A GROUNDED
METAL COLD WATER PIPE OR OTHER
ESTABLISHED GROUND.
(;+$867,1)250$7,21
:$51,1* IN CANADA AND IN THE
81,7('67$7(67+(5(48,5('(;+$867'8&7
',$0(7(5,6,1PP'212786('8&7
/21*(57+$163(&,),(',17+((;+$867
/(1*7+7$%/(
8VLQJH[KDXVWORQJHUWKDQVSHFL¿HGOHQJWKZLOO
• Increase the drying times and the energy cost.
• Reduce the dryer life.
$FFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG
7KHFRUUHFWH[KDXVWLQVWDOODWLRQLVYOUR
RESPONSIBILITY3UREOHPVGXHWRLQFRUUHFWLQVWDOODWLRQ
DUHQRWFRYHUHGE\WKHZDUUDQW\
Remove and discard existing plastic or metal foil transition
duct and replace with UL listed transition duct.
The 0$;,080$//2:$%/( duct length and number of
bends of the exhaust system depends upon the type of
duct, number of turns, the type of exhaust hood (wall cap),
and all conditions noted below. The maximum duct length
for rigid metal duct is shown in the table below.
EXHAUST LENGTH
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90º
Elbows
Rigid
Metal
Rigid
Metal
90 Feet
60 Feet
45 Feet
35 Feet
0
1
2
3
60 Feet
45 Feet
35 Feet
25 Feet
Use only
for short
run installations
(;+$8676<67(0&+(&./,67
HOOD OR WALL CAP
Terminate in a manner to prevent back drafts or entry of birds or
other wildlife.
Termination should present minimal resistance to the exhaust air
ÀRZDQGVKRXOGUHTXLUHOLWWOHRUQRPDLQWHQDQFHWRSUHYHQWFORJJLQJ
1HYHU install a screen in or over the exhaust duct. This could cause
lint build up.
Wall caps must be installed at least 12 in. above ground level or any
other obstruction with the opening pointed down.
SEPARATION OF TURNS
For best performance, separate all turns by at least 4 ft. of straight
duct, including distance between last turn and exhaust hood.
TURNS OTHER THAN 90º
• One turn of 45º or less may be ignored.
• Two 45º turns should be treated as one 90º turn.
• Each turn over 45º should be treated as one 90º turn.
SEALING OF JOINTS
All joints should be tight to avoid leaks. The male end of each section
of duct must point away from the dryer.
Do not assemble the ductwork with fasteners that extend into the
duct. They will serve as a collection point for lint.
Duct joints can be made air and moisture-tight by wrapping the
overlapped joints with duct tape.
Horizontal runs should slope down toward the outdoors 1/4
inch per foot.
INSULATION
Duct work that runs through an unheated area or is near air
conditioning should be insulated to reduce condensation and lint
build-up.
For every extra 90° elbow, reduce the allowable vent system
length by 10 ft.
Two 45° elbows will be treated like one 90° elbow.
For the side exhaust installations, add one 90° elbow to the
chart.
The total vent system length includes all the straight portions
and elbows of the system (transition duct included).
Installation Instructions
5
GAS
INLET
PIPE
EXTERNAL
DUCT
OPENING
DUCT TAPE OR
DUCT CLAMP
DUCT TAPE OR
DUCT CLAMP
(CUT TO PROPER
LENGTH)
4" METAL DUCT
CSA (AGA) APPROVED
NEW FLEXIBLE GAS
LINE CONNECTOR
NOTE: WE STRONGLY RECOMMEND SOLID METAL EXHAUST DUCTING.
HOWEVER, IF FLEXIBLE DUCTING IS USED IT MUST BE UL-LISTED METAL
NOT PLASTIC.
FOR STRAIGHT LINE INSTALLATION, CONNECT THE DRYER EXHAUST TO
THE EXTERNAL EXHAUST HOOD USING DUCT TAPE OR CLAMP.
STANDARD REAR EXHAUST
(Vented at floor level)
(;+$867&211(&7,21
THIS DRYER COMES READY FOR REAR
(;+$867,1*,) 63$&( ,6/,0,7('86(
THE INSTRUCTIONS IN SECTION 9 TO
(;+$867',5(&7/<)5207+(6,'(625
%277202)7+(&$%,1(7
RECOMMENDED
CONFIGURATION
TO MINIMIZE
EXHAUST
BLOCKAGE.
ELBOW HIGHLY
RECOMMENDED
ELBOW HIGHLY
RECOMMENDED
NOTE: ELBOWS WILL PREVENT DUCT
KINKING AND COLLAPSING.
STANDARD REAR EXHAUST
(Vented above floor level)
:$51,1*TO REDUCE THE
RISK OF FIRE OR PERSONAL INJURY:
This clothes dryer must be exhausted to the
outdoors.
We recommend that you install your dryer before
installing your washer. This will permit direct access
for easier exhaust connection.
Use only 4” rigid metal ducting for the home exhaust
duct.
 8VH RQO\ µ ULJLG PHWDO RU 8/OLVWHG ÀH[LEOH PHWDO
(semi-rigid or foil-type) duct to connect the dryer
to the home exhaust duct. It must be installed
in accordance with the instructions found in
“Connecting The Dryer To House Vent” on page 6 of
this manual.
Do not terminate exhaust in a chimney, a wall,
a ceiling, gas vent, crawl space, attic, under an
HQFORVHG ÀRRU RU LQ DQ\ RWKHU FRQFHDOHG VSDFH
of a building. The accumulated lint could create a
potential ¿UHKD]DUG
Never terminate the exhaust into a common duct
with a kitchen exhaust system. A combination of
JUHDVHDQGOLQWFUHDWHVDSRWHQWLDO¿UHKD]DUG
 'RQRWXVHGXFWORQJHUWKDQVSHFL¿HGLQWKHH[KDXVW
length table. Longer ducts can accumulate lint,
FUHDWLQJDSRWHQWLDO¿UHKD]DUG
Never install a screen in or over the exhaust duct.
This will cause lint to accumulate, creating a
SRWHQWLDO¿UHKD]DUG
Do not assemble ductwork with any fasteners
that extend into the duct. These fasteners can
DFFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG
Do not obstruct incoming or exhausted air.
• Provide an access for inspection and cleaning of
the exhaust system, especially at turns and joints.
Exhaust system shall be inspected and cleaned at
least once year.
8
/(9(/,1*'5<(5
LEVEL
SIDE-TO-SIDE.
4 LEVELING LEGS
2 ANTI-TIP LEGS
LEVEL
FRONT-TO-BACK.
STAND THE DRYER UPRIGHT NEAR THE
FINAL LOCATION AND ADJUST THE 4 LEVELING
LEGS TO MATCH THE HEIGHT OF YOUR WASHER.
ADJUST THE 2 ANTI-TIP LEGS TO CONTACT
THE FLOOR.
Installation Instructions
6
&211(&7,1*7+('5<(572+286(9(17
RIGID METAL TRANSITION DUCT
For best drying performance, a rigid metal transition duct is
recommended.
Rigid metal transitions ducts reduce the risk of crushing and kinking.
8//,67(')/(;,%/(0(7$/6(0,5,*,'75$16,7,21'8&7
 ,IULJLGPHWDOGXFWFDQQRWEHXVHGWKHQ8/OLVWHGÀH[LEOH
metal (semi-rigid) ducting can be used (Kit WX08X10077).
 1HYHULQVWDOOÀH[LEOHPHWDOGXFWLQZDOOVFHLOLQJVÀRRUVRU
other enclosed spaces.
7RWDOOHQJWKRIÀH[LEOHPHWDOGXFWVKRXOGQRWH[FHHGIHHWP
For many applications, installing elbows at both the dryer
and the wall is highly recommended (see illustrations below).
Elbows allow the dryer to sit close to the wall without kinking
and or crushing the transition duct, maximizing drying
performance.
Avoid resting the duct on sharp objects.
8//,67(')/(;,%/(0(7$/)2,/7<3(75$16,7,21'8&7
In special installations, it may be necessary to connect the
GU\HUWRWKHKRXVHYHQWXVLQJDÀH[LEOHPHWDOIRLOW\SHGXFW
$8/OLVWHGÀH[LEOHPHWDOIRLOW\SHGXFWPD\EHXVHG21/<
LQLQVWDOODWLRQVZKHUHULJLGPHWDORUÀH[LEOHPHWDOVHPLULJLG
ducting cannot be used AND where a 4” diameter can be
maintained throughout the entire length of the transition duct.
,Q&DQDGDDQGWKH8QLWHG6WDWHVRQO\WKHÀH[LEOHPHWDOIRLO
type) ducts that comply with the “Outline for Clothes Dryer
Transition Duct Subject 2158A” shall be used.
 1HYHULQVWDOOÀH[LEOHPHWDOGXFWLQZDOOVFHLOLQJVÀRRUVRU
other enclosed spaces.
7RWDOOHQJWKRIÀH[LEOHPHWDOGXFWVKRXOGQRWH[FHHGIHHWP
Avoid resting the duct on sharp objects.
For best drying performance:
1.
Slide one end of the duct over the clothes dryer outlet
pipe.
2.
Secure the duct with a clamp.
3.
With the dryer in its permanent position, extend the duct
to its full length. Allow 2” of duct to overlap the exhaust
SLSH&XWRȺDQGUHPRYHH[FHVVGXFW.HHSWKHGXFWDV
VWUDLJKWDVSRVVLEOHIRUPD[LPXPDLUÀRZ
4.
Secure the duct to the exhaust pipe with the other clamp.
ELBOWS HIGHLY
RECOMMENDED
ELBOW HIGHLY
RECOMMENDED
DO
DO NOT
SIT DRYER
ON FLEXIBLE
EXHAUST
DO NOT USE
EXCESSIVE
EXHAUST
LENGTH
DO NOT
CRUSH
FLEXIBLE
EXHAUST
AGAINST
WALL.
DON’T
9
$/&29(25&/26(7,167$//$7,21
If your dryer is approved for installation in an alcove or closet,
it will be stated on a label on the dryer back.
• The dryer MUST be vented to the outdoors. See the (;+$867
INFORMATION section.
Minimum clearance between dryer cabinet and adjacent
walls or other surfaces is:
0 in. either side
3 in. front and rear
 0LQLPXPYHUWLFDOVSDFHIURPÀRRUWRRYHUKHDGFDELQHWV
ceiling, etc. is 52 in.
Closet doors must be louvered or otherwise ventilated and
must contain a minimum of 60 sq. in. of open area equally
distributed. If the closet contains both a washer and a dryer,
doors must contain a minimum of 120 sq.in. of open area
equally distributed.
The closet should be vented to the outdoors to prevent gas
pocketing in case of a gas leak in the supply line.
No other fuel-burning appliance shall be installed in the same
closet with the dryer.
11
MOBILE OR MANUFACTURED HOME INSTALLATION
Installation must conform to the MANUFACTURED HOME
&216758&7,216$)(7<67$1'$5'7,7/(3$57
or, when such standard is not applicable, with AMERICAN
1$7,21$/67$1'$5')2502%,/(+20(12%.
• The dryer MUST be vented to the outdoors with the
termination securely fastened to the mobile home structure.
(See (;+$867,1)250$7,21 section 6.)
• The vent MUST NOT be terminated beneath a mobile or
manufactured home.
The vent duct material MUST BE METAL.
.,7'0867 be used to attach the dryer securely to
the structure.
The vent MUST NOT be connected to any other duct, vent, or
chimney.
Do not use sheet metal screws or other refastening devices
which extend into the interior of the exhaust vent.
Provide an opening with a free area of at least 25 sq. in.or
introduction of outside air into the dryer room.
Stacking of a gas dryer is not permitted in a mobile home or
manufactured home.
10
BATHROOM OR BEDROOM INSTALLATION
• The dryer MUST be vented to the outdoors. See (;+$867
INFORMATION section 6.
The installation must conform with local codes or, in the
absence of local codes, with the 1$7,21$/)8(/*$6&2'(
$16,=
Installation Instructions
7

'5<(5(;+$867725,*+7/()725
BOTTOM CABINET
:$51,1*
BEFORE PERFORMING
7+,6(;+$867
,167$//$7,21%(685(
TO DISCONNECT THE DRYER FROM ITS
(/(&75,&$/ 6833/< 3527(&7 <285
HANDS AND ARMS FROM SHARP
EDGES WHEN WORKING INSIDE THE
&$%,1(7%(685(72:($5*/29(6
Note: Only 4” round rigid metal ducting allowed inside
dryer.
TAB LOCATION
Detach and remove the bottom, right or left side knockout
as desired. Remove the screw inside the dryer exhaust duct
and save. Pull the duct out of the dr
y
er.
REMOVE
SCREW
AND SAVE.
REMOVE
DESIRED
KNOCKOUT
(ONE ONLY).
ADDING NEW DUCT
ADDING ELBOW AND DUCT FOR
(;+$86772/()76,'(2)&$%,1(7
• Preassemble 4” elbow with 4” duct. Wrap duct tape
around joint.
,QVHUWGXFWDVVHPEO\HOERZ¿UVWWKURXJKWKHVLGH
opening and connect the elbow to the dryer internal
duct.
CAUTION:%HVXUHQRWWRSXOORUGDPDJH
WKHHOHFWULFDOZLUHVLQVLGHWKHGU\HUZKHQLQVHUWLQJWKH
GXFW
• Apply duct tape as shown on the joint between the
dryer internal duct and the elbow.
Cut the duct as shown and keep portion A.
9"
AB
FIXING HOLE
Through the rear opening, locate the tab in the middle of
the appliance base. Lift the tab to about 45º using a flat
blade screwdriver.
BEND TAB
UP 45
o
Reconnect the cut portion (A) of the duct to the blower
housing. Make sure that the shortened duct is aligned with
the tab in the base. Use the screw saved previously to secure
the duct in place through the tab on the appliance base.
LEFT SIDE
EXHAUST
PORTION "A"
FIXING
HOLE
EXHAUST CAN
BE ADDED TO
LEFT OR RIGHT SIDE
DUCT
TAPE
DUCT
TAPE
CAUTION:
Internal duct joints must be
VHFXUHG ZLWK WDSH RWKHUZLVH
they may separate and cause
DVDIHW\KD]DUG
GARAGE INSTALLATION (IF ALLOWED
%</2&$/&2'(6
Dryers installed in garages must be elevated 18 inches
FPDERYHWKHÀRRU

Installation Instructions
8
$'',1*(/%2:)25(;+$867
THROUGH BOTTOM OF CABINET
Insert the elbow through the rear opening and connect
it to the dryer internal duct.
Apply duct tape on the joint between the dryer internal
duct and elbow, as shown on page 7.
$'',1*&29(53/$7(725($52)
CABINET
Connect standard metal elbows and ducts to complete
the exhaust system. Cover back opening with a plate (Kit
WE1M454) available from your local service provider. Place
GU\HULQ¿QDOORFDWLRQ
:$51,1*1(9(5/($9(7+(
%$&.23(1,1*:,7+2877+(3/$7(
PL ATE
(KIT WE1M454)
CAUTION:
Internal duct joints must be secured with tape,
otherwise they may separate and cause a
safety hazard.
CHANGING DIRECTION OF DOOR OPENING
1. 2SHQWKHGRRUDQGUHPRYHWKH¿OOHUSOXJVRSSRVLWHWKH
hinges. With the door completely open, remove the
bottom screws from each hinge on the dryer face. Insert
these screws about half way into the TOP holes, for each
KLQJHRQWKHRSSRVLWHVLGHZKHUH\RXUHPRYHGWKH¿OOHU
SOXJV$SSO\¿UPSUHVVXUHWRJHWWKHVFUHZVVWDUWHG
2. Loosen the top screws from each hinge on the dryer
face half way. With one hand holding the top of the door
and the other hand holding the bottom, remove the
door from the dryer by lifting it UP and OFF.
3. Remove the blind plate from
the hinge side of the dryer
by removing its two screws.
Remove the strike plate
from the opposite side of the
dryer by removing its two
screws. Reinstall the plates,
on the opposite sides, using
two screws in each plate.
4. Rotate the door 180º. Insert the door on the opposite
side of the opening by moving the door ON and DOWN
until the top hinge and the bottom hinge are resting on
the top screws inserted in step 1.
5. Remove the remaining screws from the side of the
opening from which the door was removed. With these
screws secure each hinge at the bottom. Tighten the
two top screws on each hinge. Reinsert the plastic plugs
on the side from which the door was removed.
LOOSEN EACH TOP HINGE
SCREW HALF WAY AND LIFT
THE DOOR UP AND OFF
14
ROTATE DOOR 180º AND HANG
IT ON TOP HINGE SCREWS
INSTALL AND TIGHTEN BOTTOM
SCREWS AND TIGHTEN TOP
SCREWS
INSERT PLUGS
INTO HOLES ON
OPPOSITE SIDE
FRONT PANEL
SWITCH
STRIKE
PLATE
BLIND
PLATE
REMOVE BOTTOM SCREW FROM EACH HINGE
AND INSTALL HALF WAY INTO EACH TOP OF
OPPOSITE HINGE HOLES
REMOVE 4 PLUGS AND KEEP
FOR INSERTION INTO
THE OPPOSITE SIDE
Installation Instructions
9
WATER SUPPLY REQUIREMENTS
Hot and cold water faucets MUST be installed within 42 in.
(107 cm) of your washer’s water inlet. The faucets MUST
be 3/4 in. (1.9 cm) garden hose-type so inlet hoses can
be connected. Water pressure MUST be between 10 and
120 pounds per square inch. Your water department can
advise you of your water pressure.
NOTE: A water softener is recommended to reduce buildup
of scale inside the steam generator if the home water
supply is very hard.
15
CONNECTING INLET HOSES
(on some models)
To produce steam, the dryer must connect to the cold
water supply. Since the washer must also connect to the
cold water, a “Y” connector is inserted to allow both inlet
hoses to make that connection at the same time.
NOTE: Use the new inlet hoses provided; never
use old hoses.
 7XUQWKHFROGZDWHUIDXFHWRȺ5HPRYHWKHZDVKHULQOHW
KRVHIURPWKHZDVKHU¿OOYDOYHFRQQHFWRUFROG
 (QVXUHWKHUXEEHUÀDWZDVKHULVLQSODFHDQGVFUHZWKH
IHPDOHFRXSOLQJRIWKHVKRUW KRVH RQWR WKH ZDVKHU¿OO
YDOYHFRQQHFWRU7LJKWHQE\KDQGXQWLO¿UPO\VHDWHG
 Attach the female end of the ‘’Y’’ connector to the male
FRXSOLQJRIWKHVKRUWKRVH(QVXUHWKHUXEEHUÀDWZDVKHU
LVLQSODFH7LJKWHQE\KDQGXQWLO¿UPO\VHDWHG
 ,QVHUW WKH ¿OWHUVFUHHQLQ WKH FRXSOLQJRI WKH ZDVKHU·V
LQOHW KRVH ,I D UXEEHU ÀDW ZDVKHU LV DOUHDG\ LQ SODFH
UHPRYHLWEHIRUHLQVWDOOLQJWKH¿OWHUVFUHHQ$WWDFKWKLV
coupling to one male end of the ‘’Y’’ connector. Tighten
E\KDQGXQWLO¿UPO\VHDWHG
 (QVXUHWKHUXEEHUÀDWZDVKHULVLQSODFHDQGDWWDFKWKH
dryer’s long inlet hose to the other male end of the ‘’Y’
FRQQHFWRU7LJKWHQE\KDQGXQWLO¿UPO\VHDWHG
 (QVXUH WKH UXEEHU ÀDW ZDVKHU LV LQ SODFH DQG DWWDFK
WKH RWKHU HQG RI WKH GU\HU·V ORQJ LQOHW KRVH WR WKH ¿OO
valve connector at the bottom of the dryer back panel.
7LJKWHQE\KDQGXQWLO¿UPO\VHDWHG
 Using pliers, tighten all the couplings with an additional
two–thirds turn.
NOTE: Do not overtighten. Damage to the couplings may
result.

6(59,&,1*
:$51,1* LABEL ALL WIRES
PRIOR TO DISCONNECTION WHEN
6(59,&,1*&21752/6:,5,1*(55256
CAN CAUSE IMPROPER AND DANGEROUS
23(5$7,21$)7(56(59,&,1*
,167$//$7,21
For servicing phone numbers for replacement parts, and
other information, refer to Owner’s Manual or visit our
Web site.
15
&211(&7,1*,1/(7+26(6FRQW
 Turn the water faucet on.
 Check for leaks around the ‘’Y’’ connector, faucet and
hose couplings.
REGISTER YOUR NEW APPLIANCE TO RECEIVE ANY
IMPORTANT PRODUCT NOTIFICATIONS.
Please go to www.GEAppliances.com or mail in your
Product Registration Card.
For questions on installation, call: 800.626.2000 (US) or
800-561-3344 (Canada).
10
Notes
Notes
11
Notes
12
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

GE Gas Dryer Guide d'installation

Taper
Guide d'installation

dans d''autres langues