INSTALLATION INSTRUCTIONS

FM-97414
HARDWARE
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Dec. 2023

Read all instructions before installing.
• System is intended for installation by a licensed electrician in accordance with the National Electrical Code (NEC) and local regulations.
When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
• Retain installation instructions for future maintenance reference.
All parts must be used as indicated in these instructions. This product is designed for use only with the supplied parts and/or
accessories designated for use by Modern Forms. Substitution of parts or accessories not designated for use with this product by Modern
Forms could result in personal injury or property damage, and will void the warranty. Contact an authorized dealer or the manufacturer if any
parts are damaged or missing.
Coastal conditions may cause mineral and residue build-up on the xture. We recommend that customers in coastal
areas clean all external surfaces of the xture once every two weeks with a wet cloth.

Lisez toutes les instructions avant l’installation.
Le système doit être installé par un électricien licensié conformément au code national de lélectricité (NEC), et également aux
règlements locaux.
Lors de la manipulation du luminaire, n’appuyez pas sur les LED. Tenez-le uniquement par la base.
 Toutes les pièces doivent être utilisées comme indiqué dans ces instructions. Ce produit est conçu pour être utilisé seulement
avec les pièces et/ou accessoires fournis pour être utilisés avec les produits Modern Forms. Remplacer des pièces ou accessoires non conçus
pour ce produit Modern Forms pourrait causer des dommages corporels ou matériels et pourrait également causer l’annulation de la
garantie. Veuillez contacter un revendeur autorisé ou le fabricant si des pièces manquent ou sont endommagées.
 Les conditions côtières peut causer une accumulation de minéraux et de résidue sur le luminaire. Nous recommendons
aux clients qui resident dans les zones côtières de nettoyer toutes les surfaces externes du luminaire une fois toutes les deux semaines avec
un chiffon humide.






2
INSTALLATION INSTRUCTIONS

FM-97414
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Dec. 2023
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
FIG. 2 Wiring

1. Shut o the power at the circuit breaker and remove existing
xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on
a clear area. Be careful not to lose any small parts necessary
for installation.

3. Remove the mounting backplate from the lampbodyand
Secure mounting backplate to the junction box using
junction box screw.
Note: (i) using any other non-original-manufacturer provided
junction box screw may result in safety issue;
(ii) The side of the mounting backplate marked “GND”
must face out.
4. Loosen the acrylic diuser from the lampbody by swing, and
take o the PC shade by loosening the assembly screw (C).

5. Connect the xture’s wires to junction box wires as shown
(Fig. 2). Make sure that all wire connectors (A) are secure. If
your outlet box has a green or bare copper ground wire,
connect the xture’s ground wire to it. Otherwise, connect
the xture’s ground wire directly to the back plate using the
screw provided. After wires are connected, tuck them
carefully inside the junction box.

6. Secure the lampbody to the jmounting backplate by using
mounting screw(B).Swing the lampbody and fasten the
mounting screw(B).
7. Secure the PC shade to the lampbody by using the
the assembly screw (C),and fasten the acrylic diffuser by
swing.
(OPTIONAL) DIMMER WIRING (Fig. 3)
Note: Dimming module (Part# LDS065M010AFE-LO1) is required in
order to utilize 0-10V dimming feature.
8. To utilize 0-10V dimming feature connect the purple (dim+)
and pink or gray (dim-) wires from the dimming module to
controller.From the dimming module connect the black (live)
or white (neutral) wires to the power sources from the junction
box and the black (output-) and blue (output+) wires to the
xture see (Fig.3) below.
Junction Box
Mounting
Backplate
Wire Connectors
Mounting Screw
Assembly Screw
Acrylic Diffuser
(RPL-GLA-97414)
PC Shade
2"
1 1/2"
Ø4
FIG. 1
Black - Live
White - Neutral
Purple - Dim+
Pink or Gray - Dim- Blue - Output+
Black- Output-
Dimming Module
FIG.3
DIMMER WIRING
  • Page 1 1