D+H DXD 150-BSY+ Mode d'emploi

Taper
Mode d'emploi
DXD 150-BSY+ (-HS)
DXD 300-BSY+ (-HS)
99.824.27 1.7/04/23
Konsolensätze bitte separat bestellen /
please order bracket sets separately /
Prière de commander séparément les kits de consoles
Standard Ausführung ohne Tubus/
Standard version without tube/
Exécution standard sans tube
Ausführung mit Tubus /
Version with tube /
Version avec tube
de Originalbetriebsanleitung . . . . . . . . . . . . . . . . . . . Seite . . . . . . . 2
Anschluss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Seite. . . . 14-15
Abmessungen. . . . . . . . . . . . . . . . . . . . . . . . . . . . Seite . . . . . . 16
en Original instructions . . . . . . . . . . . . . . . . . . . . . . . Page . . . . . . . 6
Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page. . . . 14-15
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page . . . . . . 16
fr Notice originale. . . . . . . . . . . . . . . . . . . . . . . . . . . Page . . . . . . 10
Connexion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page. . . . 14-15
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page . . . . . . 16
D+H Downloads
2/16 99.824.27 1.7/04/2399.824.27 1.7/04/23 3/16
Deutsch Deutsch
Bestimmungsgemäße Verwendung
- Zahnstangenantrieb zum elektromotorischen
Öffnen und Schließen von schweren Fenstern und
Klappen im Fassaden- und Dachbereich
- Betriebsspannung 24 V DC
- Einsetzbar für Öffnungen zur Rauchableitung,
D+H Euro-RWA gemäß DIN EN 12101-2 sowie für
täglichen Lüftungsbetrieb
- Nur für die Innenmontage geeignet
Leistungsmerkmale
- Mikroprozessorgesteuerte Synchro-Elektronik
BSY+ für sicheren und präzisen Synchronlauf
von bis zu 4 Antrieben
- Individuell programmierbar über Software SCS
- RWA-Highspeed-Funktion (Schnelllauf in AUF-
Richtung)
- Schließkantenschutz für die Hauptschließkante
- Besonders leise im Lüftungsbetrieb durch
reduzierte Motordrehzahl
Antriebseinheit mit 2,5 m Silicon-Kabel. Abhängig
vom Fenstertyp sind verschiedene Konsolensätze
separat erhältlich.
Lieferumfang
Sicherheitshinweise
Sicherheitskleinspannung 24 V DC!
Nicht am Stromnetz direkt anschließen!
- Anschluss darf nur durch eine autorisierte
Elektrofachkraft erfolgen.
- Quetschgefahr im handzugänglichen Bereich.
- Personen aus dem Fahrbereich des Antriebes
fernhalten.
- Kinder von der Steuerung fernhalten.
- Drucklast-Diagramm der Zahnstange beachten!
- Nur in trockenen Räumen verwenden.
- Nur für die Innenmontage geeignet.
Bei Gefahr durch Regen (z.B. an Lichtkuppel oder
Dachflächenfenster) Regenmelder verwenden.
- Bei Außenmontage Option -W einsetzen!
- Nur unveränderte D+H-Originalteile verwenden.
- Montageanleitung des Konsolensatzes beachten.
Beiliegenden roten Sicherheitszettel beachten!
Drucklast-Diagramm
Die maximale Drucklast der Zahnstange entspricht nicht automatisch der maximalen Druckkraft des Antriebes!
max. Last (N)
Hub (mm)
0
250
500
750
1000
1250
1500
0
500
1000
1500
2000
2500
3000
3500
DXD 150-BSY+ (-HS)
dauerhaft
kurzzeitig
DXD-BSY+ (-HS)DXD-BSY+ (-HS)
max. Last (N)
Hub (mm)
0
0
500
1000
1500
2000
2500
3000
3500
DXD 300-BSY+ (-HS)
dauerhaft
kurzzeitig
250
500
750
1000
1250
1500
I
III
100 mm
20 mm
7,1 mm/s
5 mm/s
5 mm/s
~7,1 mm/s / ~8 mm/s (~17 mm/s)
II
Schließbereiche
Typ DXD 150-BSY+ DXD 150-BSY+ HS DXD 300-BSY+ DXD 300-BSY+ HS
Versorgung 24 V DC, ±15 % 24 V DC, ±15 % 24 V DC, ±15 % 24 V DC, ±15 %
Nenn-Strom 1,4 A 2,5 A 2,5 A 5,0 A
Nenn-Kraft 1500 N 1500 N 3000 N 3000 N
Nenn-Verriegelungskraft 1400 N (ohne Konsole) 2800 N (ohne Konsole)
Lebensdauer >20 000 Doppelhübe
Einschaltdauer 30 %, bei Spielzeit 10 Minuten
Gehäuse Aluminium pulverbeschichtet / Polycarbonat
Schutzart IP 64 (“-W“ = IP 54)
Temp. Bereich -15 ... +75 °C (VdS 2580: - 5 ... +75 °C)
Temp. Standsicherheit 30 min / 300 °C
Emissions-Schalldruckpegel LpA ≤ 70 dB(A)
Nenn-Hublänge * siehe Typenschild
Zusatzfunktionen * Schließkantenschutz aktiviert (3 Wiederholungshübe)
* Programmierbar mit Software SCS
Laufgeschwindigkeiten und Kräfte
Normalbetrieb =
RWA- Schnelllauf =
Alle Kräfte
+ ca. 20 %
Abschaltreserve (kurzzeitig)
Technische Daten
Schließkantenschutz
In Laufrichtung "ZU" verfügt der Antrieb über einen
aktiven Schutz für die Hauptschließkante. Bei einer
Überlast im Schließbereich 3 und 2 fährt der Antrieb
für 10 Sekunden wieder "AUF". Danach fährt der
Antrieb wieder "ZU". Sollte nach drei Versuchen ein
Einfahren nicht möglich sein, bleibt der Antrieb in
dieser Stellung stehen.
Zusätzlich verfügt der Antrieb über einen passiven
Klemmschutz. Die Schließgeschwindigkeit wird im
Schließbereich 2 und 1 auf 5 mm/s reduziert.
An den Nebenschließkanten können
deutlich höhere Kräfte auftreten.
Quetschgefahr im handzugänglichen
Bereich.
Hauptschließkante
Nebenschließkante
Nebenschließkante
AUF
Kräfte
SB III
SB II
SB I
1500 N
1000 N
1000 N
800 N
3000 N
2000 N
1600 N
800 N
DXD 150-BSY+ (-HS) DXD 300-BSY+ (-HS)
ZU
abhängig von Magnetposition
Bei dem Typ DXD 150-BSY+ (-HS) sind Lasten von
über 1000 N bis zu 1500 N sind nur kurzzeitig
zulässig (z. B. zum Schneeabwerfen oder bei Wind-
belastungen). Diese dürfen bis zu einem Hub von
1750 mm auftreten.
Bei dem Typ DXD 300-BSY+ (-HS) sind Lasten von
über 2000 N bis zu 3000 N sind nur kurzzeitig
zulässig (z. B. zum Schneeabwerfen oder bei Wind-
belastungen). Diese dürfen bis zu einem Hub von
1500 mm auftreten.
WARNUNG
Lesen Sie alle Sicherheitshinweise, Anweisungen,
Bebilderungen und technischen Daten, mit denen
dieses Produkt versehen ist.
Versäumnisse bei der Einhaltung der
nachfolgenden Anweisungen können elektrischen
Schlag, Brand und/oder schwere Verletzungen
verursachen.
Bewahren Sie alle Sicherheitshinweise und
Anweisungen für die Zukunft auf.
2/16 99.824.27 1.7/04/2399.824.27 1.7/04/23 3/16
Deutsch Deutsch
Bestimmungsgemäße Verwendung
- Zahnstangenantrieb zum elektromotorischen
Öffnen und Schließen von schweren Fenstern und
Klappen im Fassaden- und Dachbereich
- Betriebsspannung 24 V DC
- Einsetzbar für Öffnungen zur Rauchableitung,
D+H Euro-RWA gemäß DIN EN 12101-2 sowie für
täglichen Lüftungsbetrieb
- Nur für die Innenmontage geeignet
Leistungsmerkmale
- Mikroprozessorgesteuerte Synchro-Elektronik
BSY+ für sicheren und präzisen Synchronlauf
von bis zu 4 Antrieben
- Individuell programmierbar über Software SCS
- RWA-Highspeed-Funktion (Schnelllauf in AUF-
Richtung)
- Schließkantenschutz für die Hauptschließkante
- Besonders leise im Lüftungsbetrieb durch
reduzierte Motordrehzahl
Antriebseinheit mit 2,5 m Silicon-Kabel. Abhängig
vom Fenstertyp sind verschiedene Konsolensätze
separat erhältlich.
Lieferumfang
Sicherheitshinweise
Sicherheitskleinspannung 24 V DC!
Nicht am Stromnetz direkt anschließen!
- Anschluss darf nur durch eine autorisierte
Elektrofachkraft erfolgen.
- Quetschgefahr im handzugänglichen Bereich.
- Personen aus dem Fahrbereich des Antriebes
fernhalten.
- Kinder von der Steuerung fernhalten.
- Drucklast-Diagramm der Zahnstange beachten!
- Nur in trockenen Räumen verwenden.
- Nur für die Innenmontage geeignet.
Bei Gefahr durch Regen (z.B. an Lichtkuppel oder
Dachflächenfenster) Regenmelder verwenden.
- Bei Außenmontage Option -W einsetzen!
- Nur unveränderte D+H-Originalteile verwenden.
- Montageanleitung des Konsolensatzes beachten.
Beiliegenden roten Sicherheitszettel beachten!
Drucklast-Diagramm
Die maximale Drucklast der Zahnstange entspricht nicht automatisch der maximalen Druckkraft des Antriebes!
max. Last (N)
Hub (mm)
0
250
500
750
1000
1250
1500
0
500
1000
1500
2000
2500
3000
3500
DXD 150-BSY+ (-HS)
dauerhaft
kurzzeitig
DXD-BSY+ (-HS)DXD-BSY+ (-HS)
max. Last (N)
Hub (mm)
0
0
500
1000
1500
2000
2500
3000
3500
DXD 300-BSY+ (-HS)
dauerhaft
kurzzeitig
250
500
750
1000
1250
1500
I
III
100 mm
20 mm
7,1 mm/s
5 mm/s
5 mm/s
~7,1 mm/s / ~8 mm/s (~17 mm/s)
II
Schließbereiche
Typ DXD 150-BSY+ DXD 150-BSY+ HS DXD 300-BSY+ DXD 300-BSY+ HS
Versorgung 24 V DC, ±15 % 24 V DC, ±15 % 24 V DC, ±15 % 24 V DC, ±15 %
Nenn-Strom 1,4 A 2,5 A 2,5 A 5,0 A
Nenn-Kraft 1500 N 1500 N 3000 N 3000 N
Nenn-Verriegelungskraft 1400 N (ohne Konsole) 2800 N (ohne Konsole)
Lebensdauer >20 000 Doppelhübe
Einschaltdauer 30 %, bei Spielzeit 10 Minuten
Gehäuse Aluminium pulverbeschichtet / Polycarbonat
Schutzart IP 64 (“-W“ = IP 54)
Temp. Bereich -15 ... +75 °C (VdS 2580: - 5 ... +75 °C)
Temp. Standsicherheit 30 min / 300 °C
Emissions-Schalldruckpegel LpA ≤ 70 dB(A)
Nenn-Hublänge * siehe Typenschild
Zusatzfunktionen * Schließkantenschutz aktiviert (3 Wiederholungshübe)
* Programmierbar mit Software SCS
Laufgeschwindigkeiten und Kräfte
Normalbetrieb =
RWA- Schnelllauf =
Alle Kräfte
+ ca. 20 %
Abschaltreserve (kurzzeitig)
Technische Daten
Schließkantenschutz
In Laufrichtung "ZU" verfügt der Antrieb über einen
aktiven Schutz für die Hauptschließkante. Bei einer
Überlast im Schließbereich 3 und 2 fährt der Antrieb
für 10 Sekunden wieder "AUF". Danach fährt der
Antrieb wieder "ZU". Sollte nach drei Versuchen ein
Einfahren nicht möglich sein, bleibt der Antrieb in
dieser Stellung stehen.
Zusätzlich verfügt der Antrieb über einen passiven
Klemmschutz. Die Schließgeschwindigkeit wird im
Schließbereich 2 und 1 auf 5 mm/s reduziert.
An den Nebenschließkanten können
deutlich höhere Kräfte auftreten.
Quetschgefahr im handzugänglichen
Bereich.
Hauptschließkante
Nebenschließkante
Nebenschließkante
AUF
Kräfte
SB III
SB II
SB I
1500 N
1000 N
1000 N
800 N
3000 N
2000 N
1600 N
800 N
DXD 150-BSY+ (-HS) DXD 300-BSY+ (-HS)
ZU
abhängig von Magnetposition
Bei dem Typ DXD 150-BSY+ (-HS) sind Lasten von
über 1000 N bis zu 1500 N sind nur kurzzeitig
zulässig (z. B. zum Schneeabwerfen oder bei Wind-
belastungen). Diese dürfen bis zu einem Hub von
1750 mm auftreten.
Bei dem Typ DXD 300-BSY+ (-HS) sind Lasten von
über 2000 N bis zu 3000 N sind nur kurzzeitig
zulässig (z. B. zum Schneeabwerfen oder bei Wind-
belastungen). Diese dürfen bis zu einem Hub von
1500 mm auftreten.
WARNUNG
Lesen Sie alle Sicherheitshinweise, Anweisungen,
Bebilderungen und technischen Daten, mit denen
dieses Produkt versehen ist.
Versäumnisse bei der Einhaltung der
nachfolgenden Anweisungen können elektrischen
Schlag, Brand und/oder schwere Verletzungen
verursachen.
Bewahren Sie alle Sicherheitshinweise und
Anweisungen für die Zukunft auf.
Eine DXD-BSY+ (-HS) Synchrongruppe kann aus
bis zu 4 Antrieben bestehen, welche über einen Bus
kommunizieren. Jeder Antrieb hat seine eigene
Adresse. Diese ist mittels Software SCS
konfigurierbar. Der letzte Antrieb einer Synchron-
gruppe ist der Master, welcher die restlichen
Antriebe, die Slaves, steuert. Kraftdifferenzen
zwischen den Antrieben einer Synchrongruppe
werden durch eine intelligente Kraft- und Positions-
regelung ausgeglichen. Bei Störung bzw. Ausfall
eines Antriebes werden alle Antriebe automatisch
abgeschaltet.
Funktionsbeschreibung
99.824.27 1.7/04/2399.824.27 1.7/04/23
4/16 5/16
Deutsch Deutsch
Sichtprüfung:
Es darf nur ein Master Antrieb vorhanden sein.
Der Master hat, entsprechend der Anzahl der
gesamt Antriebe, die letzte Adresse.
Die Adresse ist auf den Antrieb aufgeklebt.
Slave Antriebe sind abwärts durchnummeriert.
Bsp.: In einer Gruppe, bestehend aus 3 Antrieben,
gibt es einen Master 3, einen Slave 2 und einen
Slave 1 Antrieb.
Achtung: gilt nur bei Auslieferzustand. Sobald die
Antriebe mittels SCS neu konfiguriert wur-
den gilt die werksseitige Adressierung nicht mehr!
Verdrahtung:
Ist die Gruppe ordnungsgemäß verdrahtet?
Siehe dazu Anschlusspläne
Nullabgleich:
Nullabgleich durchführen.
Software SCS oder spezieller Magnet
MAG 502 wird benötigt.
D+H Service anrufen:
Konfigurierung der Antriebe erforderlich.
Die Software SCS wird benötigt.
Störungssuche
DXD-BSY+ (-HS)DXD-BSY+ (-HS)
Option -BRV
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
GY (-BRV)
PK (n.c.)
Option -SGI/-SKS
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
GY (-SGI/SKS)
PK (+SGI/SKS)
Option -SA-SZ
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
GY (-SZ)
GN (-SZ)
PK (-SA)
YE (-SA)
WH (n.c.)
BN (n.c.)
OG (n.c.)
Aderbelegung Stecker
Standard
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
Antriebskabel umsetzen
Antrieb Spannungsfrei schalten!
Anschluss: Seite 14 - 15
mind. 5mm
mind.
60mm
X
X
ZU-Magnet
NS
AUF-Magnet
N
S
Hubverkürzung
Zur Hubverkürzung Schlitzstifte und Magneten mit
einem geeigneten Werkzeug z.B. einem Schrauben-
dreher an die gewünschte Position
verschieben. Dabei Mindestabstände
(60 mm und 5 mm) unbedingt
einhalten!
Nach dem Verschieben
Des "ZU-Magneten“
den Antrieb zufahren
lassen, Er wird dann
automatisch auf
einen neuen Null-
Punkt gesetzt!
Ansicht X
Schlitzstift
Schlitzstift
2 Magnete
Bei einer Hubverrzung in
einer Antriebsgruppe (2 - 4
Antriebe) müssen immer alle
Magnete auf das gleiche Maß
(Toleranz ± 2,5 mm über alle Antriebe
gesehen) verschoben werden!
Ansicht X
Schlitzstift
Schlitzstift
zweites Anschlußkabel
- Der Schwenkraum des Antriebes muss über den
gesamten Hubbereich frei gehen. Anderenfalls
kann die Zahnstange und Aufhängung beschädigt
werden.
- Das Antriebsset ist vom Werk aus eingestellt. Bei
Veränderungen des Auslieferzustandes (wie z. B.
Antriebe aus bestehendem Set herausnehmen
bzw. neu eingliedern) müssen die Antriebe mit
SCS neu programmiert werden.
- Nur Antriebe mit gleicher Kraft verwenden.
- Gleichmäßige Lastverteilung auf alle Antriebe
beachten.
Montagehinweise
Wartung und Reinigung
Wartungs- und Reinigungsarbeiten nur in spannungsfreien
Zustand durchführen. Die Inspektion und Wartung hat
gemäß den D+H-Wartungshinweisen zu erfolgen. Es
dürfen nur original D+H-Ersatzteile verwendet werden.
Eine Instandsetzung erfolgt ausschließlich durch D+H.
Wischen Sie Verschmutzungen mit einem trockenen,
weichen Tuch ab.
Verwenden Sie keine Reinigungs- oder Lösemittel.
Elektrogeräte, Zubehör, Batterien und Verpackungen
sollen einer umweltgerechten Wiederverwertung
zugehrt werden. Werfen Sie Elektrogeräte und
Batterien nicht in den Hausmüll!
Nur für EU-Länder:
Gemäß der Europäischen Richtlinie 2012/19/EU
über Elektro- und Elektronik-Altgeräte und ihrer
Umsetzung in nationales Recht müssen nicht mehr
gebrauchsfähige Elektrogeräte getrennt gesammelt
und einer umweltgerechten Wiederverwertung
zugeführt werden.
Entsorgung
Konformitätserklärung
Wir erklären in alleiniger Verantwortung, dass das
unter „Technische Daten“ beschriebene Produkt mit
den folgenden Richtlinien übereinstimmt:
2014/30/EU, 2011/65/EU
S.I. 2016/1091, S.I. 2012/3032
Technische Unterlagen bei:
D+H Mechatronic AG, D-22949 Ammersbek
Dirk Dingfelder Maik Schmees
CEO CTO
24.10.2022
Option -SA-SZ
BN (Mot. b)
YE (Data A)
GN (Data B)
OG
GY
PK
WH (Mot. a)
max. 48V / 1A
r
s
Eine DXD-BSY+ (-HS) Synchrongruppe kann aus
bis zu 4 Antrieben bestehen, welche über einen Bus
kommunizieren. Jeder Antrieb hat seine eigene
Adresse. Diese ist mittels Software SCS
konfigurierbar. Der letzte Antrieb einer Synchron-
gruppe ist der Master, welcher die restlichen
Antriebe, die Slaves, steuert. Kraftdifferenzen
zwischen den Antrieben einer Synchrongruppe
werden durch eine intelligente Kraft- und Positions-
regelung ausgeglichen. Bei Störung bzw. Ausfall
eines Antriebes werden alle Antriebe automatisch
abgeschaltet.
Funktionsbeschreibung
99.824.27 1.7/04/2399.824.27 1.7/04/23
4/16 5/16
Deutsch Deutsch
Sichtprüfung:
Es darf nur ein Master Antrieb vorhanden sein.
Der Master hat, entsprechend der Anzahl der
gesamt Antriebe, die letzte Adresse.
Die Adresse ist auf den Antrieb aufgeklebt.
Slave Antriebe sind abwärts durchnummeriert.
Bsp.: In einer Gruppe, bestehend aus 3 Antrieben,
gibt es einen Master 3, einen Slave 2 und einen
Slave 1 Antrieb.
Achtung: gilt nur bei Auslieferzustand. Sobald die
Antriebe mittels SCS neu konfiguriert wur-
den gilt die werksseitige Adressierung nicht mehr!
Verdrahtung:
Ist die Gruppe ordnungsgemäß verdrahtet?
Siehe dazu Anschlusspläne
Nullabgleich:
Nullabgleich durchführen.
Software SCS oder spezieller Magnet
MAG 502 wird benötigt.
D+H Service anrufen:
Konfigurierung der Antriebe erforderlich.
Die Software SCS wird benötigt.
Störungssuche
DXD-BSY+ (-HS)DXD-BSY+ (-HS)
Option -BRV
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
GY (-BRV)
PK (n.c.)
Option -SGI/-SKS
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
GY (-SGI/SKS)
PK (+SGI/SKS)
Option -SA-SZ
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
GY (-SZ)
GN (-SZ)
PK (-SA)
YE (-SA)
WH (n.c.)
BN (n.c.)
OG (n.c.)
Aderbelegung Stecker
Standard
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
Antriebskabel umsetzen
Antrieb Spannungsfrei schalten!
Anschluss: Seite 14 - 15
mind. 5mm
mind.
60mm
X
X
ZU-Magnet
NS
AUF-Magnet
N
S
Hubverkürzung
Zur Hubverkürzung Schlitzstifte und Magneten mit
einem geeigneten Werkzeug z.B. einem Schrauben-
dreher an die gewünschte Position
verschieben. Dabei Mindestabstände
(60 mm und 5 mm) unbedingt
einhalten!
Nach dem Verschieben
Des "ZU-Magneten“
den Antrieb zufahren
lassen, Er wird dann
automatisch auf
einen neuen Null-
Punkt gesetzt!
Ansicht X
Schlitzstift
Schlitzstift
2 Magnete
Bei einer Hubverrzung in
einer Antriebsgruppe (2 - 4
Antriebe) müssen immer alle
Magnete auf das gleiche Maß
(Toleranz ± 2,5 mm über alle Antriebe
gesehen) verschoben werden!
Ansicht X
Schlitzstift
Schlitzstift
zweites Anschlußkabel
- Der Schwenkraum des Antriebes muss über den
gesamten Hubbereich frei gehen. Anderenfalls
kann die Zahnstange und Aufhängung beschädigt
werden.
- Das Antriebsset ist vom Werk aus eingestellt. Bei
Veränderungen des Auslieferzustandes (wie z. B.
Antriebe aus bestehendem Set herausnehmen
bzw. neu eingliedern) müssen die Antriebe mit
SCS neu programmiert werden.
- Nur Antriebe mit gleicher Kraft verwenden.
- Gleichmäßige Lastverteilung auf alle Antriebe
beachten.
Montagehinweise
Wartung und Reinigung
Wartungs- und Reinigungsarbeiten nur in spannungsfreien
Zustand durchführen. Die Inspektion und Wartung hat
gemäß den D+H-Wartungshinweisen zu erfolgen. Es
dürfen nur original D+H-Ersatzteile verwendet werden.
Eine Instandsetzung erfolgt ausschließlich durch D+H.
Wischen Sie Verschmutzungen mit einem trockenen,
weichen Tuch ab.
Verwenden Sie keine Reinigungs- oder Lösemittel.
Elektrogeräte, Zubehör, Batterien und Verpackungen
sollen einer umweltgerechten Wiederverwertung
zugehrt werden. Werfen Sie Elektrogeräte und
Batterien nicht in den Hausmüll!
Nur für EU-Länder:
Gemäß der Europäischen Richtlinie 2012/19/EU
über Elektro- und Elektronik-Altgeräte und ihrer
Umsetzung in nationales Recht müssen nicht mehr
gebrauchsfähige Elektrogeräte getrennt gesammelt
und einer umweltgerechten Wiederverwertung
zugeführt werden.
Entsorgung
Konformitätserklärung
Wir erklären in alleiniger Verantwortung, dass das
unter „Technische Daten“ beschriebene Produkt mit
den folgenden Richtlinien übereinstimmt:
2014/30/EU, 2011/65/EU
S.I. 2016/1091, S.I. 2012/3032
Technische Unterlagen bei:
D+H Mechatronic AG, D-22949 Ammersbek
Dirk Dingfelder Maik Schmees
CEO CTO
24.10.2022
Option -SA-SZ
BN (Mot. b)
YE (Data A)
GN (Data B)
OG
GY
PK
WH (Mot. a)
max. 48V / 1A
r
s
max. Load (N)
Stroke (mm)
0
250
500
750
1000
1250
1500
0
500
1000
1500
2000
2500
3000
3500
DXD 150-BSY+ (-HS)
durable
temporary
max. Load (N)
Stroke (mm)
0
0
500
1000
1500
2000
2500
3000
3500
DXD 300-BSY+ (-HS)
durable
temporary
250
500
750
1000
1250
1500
99.824.27 1.7/04/2399.824.27 1.7/04/23
6/16 7/16
English English
Intended use
- Rack and pinion drive for electric opening and
closing of heavy windows and flaps in the facade
and roof area
- Operating voltage 24 V DC
- Usheable for smoke ventilation, D+H Euro-SHEV
according to DIN EN 12101-2 as well as daily
natural ventilation
- Only for inside mounting
Performance features
- micro processor controlled synchro electronics
BSY + for a precise synchronous run of up to
8 drives
- individually programmable (via software SCS)
- SHEV-high speed function (fast-running
feature in OPEN-direction)
- closing edge protection for the main closing edge
- especially silent in ventilation operation
because of reduced motor speed
Drive unit with 2,5 m silicone cable. Dependent on
the type of window, different bracket sets are
available separately.
Extent of supply
Safety notes
Safety extra low voltage 24 V DC!
Do not connect directly to the mains supply!
- Connection has to be carried out only by an
authorized electrical specialist
- Danger of violent pressure in handaccessible area.
- Keep away People from the operating area of the
drive
- Keep away children from the control.
- Observe pressure load diagram of the toothed rack!
- Use only in dry rooms
- Only for inside mounting
Use rain detector with danger of rain
(e.g. at domelights or roof windows)
- Use option “-W“ in case of outside mounting!
- Just use unchanged original D+H parts
- Observe mounting instructions of bracket set!
Observe enclosed r ed safety slip!
DXD-BSY+ (-HS)DXD-BSY+ (-HS)
Pressure load diagram
Maximum pressure load of the toothed rack is not automatically identical with maximum pressure force of the drive!
Closing edge protection
main closing edge
beside closing edge
beside closing edge
In "CLOSE" direction the drive has an active
protection for the main closing edge. With an
overload in the closing range 3 and 2 the drive runs
"OPEN" for 10 seconds, then drive "CLOSE" again. If
after three attempts a closing is not possible, the
drive remains in this position.
In addition, the drive has a passive clamping
protection. The closing speed in closure Range 2
and 1 is reduced to 5 mm/s.
Higher forces can occur on besides
closing edges. Danger of violent
pressure in handaccessible area.
Type DXD 150-BSY+ DXD 150-BSY+ HS DXD 300-BSY+ DXD 300-BSY+ HS
Power supply 24 V DC, ±15 % 24 V DC, ±15 % 24 V DC, ±15 % 24 V DC, ±15 %
Nominal current 1,4 A 2,5 A 2,5 A 5,0 A
Nominal force 1500 N 1500 N 3000 N 3000 N
Nominal locking force 1400 N (without bracket) 2800 N (without bracket)
Lifetime >20 000 double strokes
Duty cycle 30 % (with cycle time 10 minutes)
Housing aluminium powder-coated / polycarbonate
Ingress protection IP 64 (“-W“ = IP 54)
Temperature range -15 ... +75 °C (VdS 2580: - 5 ... +75 °C)
Fire stability 30 min / 300 °C
Emission sound pressure
level LpA ≤ 70 dB(A)
Nominal stroke length* see type plate
Additional functions * closing edge protection activated (3 stroke repeatings)
* programmable with software SCS
Technical data
All forces
+ app. 20 %
switch-off reserve (temporary)
Normal operation =
SHEV- fast running =
OPEN
Forces
CR III
CR II
CR I
1500 N
1000 N
1000 N
800 N
3000 N
2000 N
1600 N
800 N
DXD 150-BSY+ (-HS) DXD 300-BSY+ (-HS)
CLOSE
I
III
100 mm
20 mm
7,1 mm/s
5 mm/s
5 mm/s
~7,1 mm/s / ~8 mm/s (~17 mm/s)
II
depending on magnet position
Running speed and forces
At the DXD 150-BSY+ (-HS) loads of more than 1000
N up to 1500 N are transient admissible only (e.g.
prior to snow removal or in case of wind loads).
These may occur up to a stroke of 1750 mm.
At the DXD 300-BSY+ (-HS) loads of more than 2000
N up to 3000 N are transient admissible only (e.g.
prior to snow removal or in case of wind loads).
These may occur up to a stroke of 1500 mm.
WARNING
Read all safety warnings, instructions, illustrations
and specifications provided with this product.
Failure to follow all instructions listed below may
result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future
reference.
max. Load (N)
Stroke (mm)
0
250
500
750
1000
1250
1500
0
500
1000
1500
2000
2500
3000
3500
DXD 150-BSY+ (-HS)
durable
temporary
max. Load (N)
Stroke (mm)
0
0
500
1000
1500
2000
2500
3000
3500
DXD 300-BSY+ (-HS)
durable
temporary
250
500
750
1000
1250
1500
99.824.27 1.7/04/2399.824.27 1.7/04/23
6/16 7/16
English English
Intended use
- Rack and pinion drive for electric opening and
closing of heavy windows and flaps in the facade
and roof area
- Operating voltage 24 V DC
- Usheable for smoke ventilation, D+H Euro-SHEV
according to DIN EN 12101-2 as well as daily
natural ventilation
- Only for inside mounting
Performance features
- micro processor controlled synchro electronics
BSY + for a precise synchronous run of up to
8 drives
- individually programmable (via software SCS)
- SHEV-high speed function (fast-running
feature in OPEN-direction)
- closing edge protection for the main closing edge
- especially silent in ventilation operation
because of reduced motor speed
Drive unit with 2,5 m silicone cable. Dependent on
the type of window, different bracket sets are
available separately.
Extent of supply
Safety notes
Safety extra low voltage 24 V DC!
Do not connect directly to the mains supply!
- Connection has to be carried out only by an
authorized electrical specialist
- Danger of violent pressure in handaccessible area.
- Keep away People from the operating area of the
drive
- Keep away children from the control.
- Observe pressure load diagram of the toothed rack!
- Use only in dry rooms
- Only for inside mounting
Use rain detector with danger of rain
(e.g. at domelights or roof windows)
- Use option “-W“ in case of outside mounting!
- Just use unchanged original D+H parts
- Observe mounting instructions of bracket set!
Observe enclosed r ed safety slip!
DXD-BSY+ (-HS)DXD-BSY+ (-HS)
Pressure load diagram
Maximum pressure load of the toothed rack is not automatically identical with maximum pressure force of the drive!
Closing edge protection
main closing edge
beside closing edge
beside closing edge
In "CLOSE" direction the drive has an active
protection for the main closing edge. With an
overload in the closing range 3 and 2 the drive runs
"OPEN" for 10 seconds, then drive "CLOSE" again. If
after three attempts a closing is not possible, the
drive remains in this position.
In addition, the drive has a passive clamping
protection. The closing speed in closure Range 2
and 1 is reduced to 5 mm/s.
Higher forces can occur on besides
closing edges. Danger of violent
pressure in handaccessible area.
Type DXD 150-BSY+ DXD 150-BSY+ HS DXD 300-BSY+ DXD 300-BSY+ HS
Power supply 24 V DC, ±15 % 24 V DC, ±15 % 24 V DC, ±15 % 24 V DC, ±15 %
Nominal current 1,4 A 2,5 A 2,5 A 5,0 A
Nominal force 1500 N 1500 N 3000 N 3000 N
Nominal locking force 1400 N (without bracket) 2800 N (without bracket)
Lifetime >20 000 double strokes
Duty cycle 30 % (with cycle time 10 minutes)
Housing aluminium powder-coated / polycarbonate
Ingress protection IP 64 (“-W“ = IP 54)
Temperature range -15 ... +75 °C (VdS 2580: - 5 ... +75 °C)
Fire stability 30 min / 300 °C
Emission sound pressure
level LpA ≤ 70 dB(A)
Nominal stroke length* see type plate
Additional functions * closing edge protection activated (3 stroke repeatings)
* programmable with software SCS
Technical data
All forces
+ app. 20 %
switch-off reserve (temporary)
Normal operation =
SHEV- fast running =
OPEN
Forces
CR III
CR II
CR I
1500 N
1000 N
1000 N
800 N
3000 N
2000 N
1600 N
800 N
DXD 150-BSY+ (-HS) DXD 300-BSY+ (-HS)
CLOSE
I
III
100 mm
20 mm
7,1 mm/s
5 mm/s
5 mm/s
~7,1 mm/s / ~8 mm/s (~17 mm/s)
II
depending on magnet position
Running speed and forces
At the DXD 150-BSY+ (-HS) loads of more than 1000
N up to 1500 N are transient admissible only (e.g.
prior to snow removal or in case of wind loads).
These may occur up to a stroke of 1750 mm.
At the DXD 300-BSY+ (-HS) loads of more than 2000
N up to 3000 N are transient admissible only (e.g.
prior to snow removal or in case of wind loads).
These may occur up to a stroke of 1500 mm.
WARNING
Read all safety warnings, instructions, illustrations
and specifications provided with this product.
Failure to follow all instructions listed below may
result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future
reference.
A synchron-group DXD-BSY+ (-HS) can be count up
to 4 drives, which communicate by a bus. Each drive
has it’s own adress. This adress is configurable with
SCS.
The last drive of a synchron-group is the master,
which controls the other drives, the slaves. Different
forces between the drives of a group will balanced
with intelligent force- and position control. In case of
malfunction respective cutoff of a drive, all drives will
shut down from the master-drive.
Functional description
99.824.27 1.7/04/2399.824.27 1.7/04/23
8/16 9/16
English English
Visual inspection:
Only one master-drive allowed.
The master has, according to common drives,
the last adress.
The adress is sticked on the drive. Slaves are
nubered downwards.
Example: In a group, composed of 3 drives,
there is a master 3, a slave 2 and a slave 1drive.
Attention: only applies by factory set. as soon as
the drives were reprogramized with software
SCS. The factory set adressing does not apply
any longer.
Wiring:
Is the group wired correctly?
Therefore look connection diagrams.
Null balance:
It should be null balanced.
Software SCS or the special magnet
MAG 502 is required.
Call D+H Service:
Drives must be configured.
Software SCS is required.
Trouble shooting
DXD -BSY+ (-HS)DXD -BSY+ (-HS)
Pin Assignment
Connection: page 14 - 15
Shifting of drive cable
Disconnect drive from electric voltage!
min. 5mm
min.
60mm
X
X
CLOSED-magnet
NS
OPEN-magnet
N
S
Stroke shortening
Shift slotted pins and magnets into desired position,
using a suitable tool e.g. a screw driver for
stroke shortening. Observe minimum
distances (60 mm und 5 mm)!
After shifting of the
“CLOSED-magnet”
let the drive run closed.
In this process, it will
be automatically set
on a new zero point!
In case of stroke shortening in
one drive group (2 - 4 drives), all
magnets must be shifted always
to the same proportion (tolerance
±2,5 mm for all drives together)!
View X
slotted pin
slotted pin
2 magnets
Option -BRV
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
GY (-BRV)
PK (n.c.)
Option -SGI/-SKS
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
GY (-SGI/SKS)
PK (+SGI/SKS)
Standard
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
Electrical devices, accessories, batteries and packa-
ging should be sorted for environmental-friendly
recycling. Do not dispose electrical devices and
batteries into household waste!
Only for EC countries:
According the European Guideline 2012/19/EU for
waste electrical and electronic equipment and its
implementation into national right, electrcal devices
that are no longer usable must be collected separa-
tely and disposed of in an environmentally correct
manner.
Disposal
Maintenance and cleaning
Maintenance work is only allowed when the device is in
a de-energized condition! Inspection and maintenance
has to be carried out according to D+H maintenance
notes. Only original D+H spare parts may be used.
Repair is to be carried out exclusively by D+H.
Wipe away debris or contamination with a dry, soft
cloth.
Do not use cleaning agents or solvents.
Mounting informations
- Swivel radius of the drive must go free over entire
range of stroke. Otherwise, the toothed rack and
the suspension can be damaged.
- The drive set will be full configured by factory.
The drives must be reconfigured in case of
alterations (e.g. removing of drives from existing
set or integrating a new drive) with SCS.
- Use only drives with the same force.
- Ensure evenly load distribution on all the drives.
Declaration of Conformity
We declare under our sole responsibility that the
product described under Technical Data” is in
conformity with the following :regulations
2014/30/EU, 2011/65/EU
S.I. 2016/1091, S.I. 2012/3032
Technical file at:
D+H Mechatronic AG, D-22949 Ammersbek
Dirk Dingfelder Maik Schmees
CEO CTO
24.10.2022
Option -SA-SZ
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
GY (-SZ)
GN (-SZ)
PK (-SA)
YE (-SA)
WH (n.c.)
BN (n.c.)
OG (n.c.)
second connecting cable
max. 48V / 1A
r
s
A synchron-group DXD-BSY+ (-HS) can be count up
to 4 drives, which communicate by a bus. Each drive
has it’s own adress. This adress is configurable with
SCS.
The last drive of a synchron-group is the master,
which controls the other drives, the slaves. Different
forces between the drives of a group will balanced
with intelligent force- and position control. In case of
malfunction respective cutoff of a drive, all drives will
shut down from the master-drive.
Functional description
99.824.27 1.7/04/2399.824.27 1.7/04/23
8/16 9/16
English English
Visual inspection:
Only one master-drive allowed.
The master has, according to common drives,
the last adress.
The adress is sticked on the drive. Slaves are
nubered downwards.
Example: In a group, composed of 3 drives,
there is a master 3, a slave 2 and a slave 1drive.
Attention: only applies by factory set. as soon as
the drives were reprogramized with software
SCS. The factory set adressing does not apply
any longer.
Wiring:
Is the group wired correctly?
Therefore look connection diagrams.
Null balance:
It should be null balanced.
Software SCS or the special magnet
MAG 502 is required.
Call D+H Service:
Drives must be configured.
Software SCS is required.
Trouble shooting
DXD -BSY+ (-HS)DXD -BSY+ (-HS)
Pin Assignment
Connection: page 14 - 15
Shifting of drive cable
Disconnect drive from electric voltage!
min. 5mm
min.
60mm
X
X
CLOSED-magnet
NS
OPEN-magnet
N
S
Stroke shortening
Shift slotted pins and magnets into desired position,
using a suitable tool e.g. a screw driver for
stroke shortening. Observe minimum
distances (60 mm und 5 mm)!
After shifting of the
“CLOSED-magnet”
let the drive run closed.
In this process, it will
be automatically set
on a new zero point!
In case of stroke shortening in
one drive group (2 - 4 drives), all
magnets must be shifted always
to the same proportion (tolerance
±2,5 mm for all drives together)!
View X
slotted pin
slotted pin
2 magnets
Option -BRV
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
GY (-BRV)
PK (n.c.)
Option -SGI/-SKS
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
GY (-SGI/SKS)
PK (+SGI/SKS)
Standard
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
Electrical devices, accessories, batteries and packa-
ging should be sorted for environmental-friendly
recycling. Do not dispose electrical devices and
batteries into household waste!
Only for EC countries:
According the European Guideline 2012/19/EU for
waste electrical and electronic equipment and its
implementation into national right, electrcal devices
that are no longer usable must be collected separa-
tely and disposed of in an environmentally correct
manner.
Disposal
Maintenance and cleaning
Maintenance work is only allowed when the device is in
a de-energized condition! Inspection and maintenance
has to be carried out according to D+H maintenance
notes. Only original D+H spare parts may be used.
Repair is to be carried out exclusively by D+H.
Wipe away debris or contamination with a dry, soft
cloth.
Do not use cleaning agents or solvents.
Mounting informations
- Swivel radius of the drive must go free over entire
range of stroke. Otherwise, the toothed rack and
the suspension can be damaged.
- The drive set will be full configured by factory.
The drives must be reconfigured in case of
alterations (e.g. removing of drives from existing
set or integrating a new drive) with SCS.
- Use only drives with the same force.
- Ensure evenly load distribution on all the drives.
Declaration of Conformity
We declare under our sole responsibility that the
product described under Technical Data” is in
conformity with the following :regulations
2014/30/EU, 2011/65/EU
S.I. 2016/1091, S.I. 2012/3032
Technical file at:
D+H Mechatronic AG, D-22949 Ammersbek
Dirk Dingfelder Maik Schmees
CEO CTO
24.10.2022
Option -SA-SZ
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
GY (-SZ)
GN (-SZ)
PK (-SA)
YE (-SA)
WH (n.c.)
BN (n.c.)
OG (n.c.)
second connecting cable
max. 48V / 1A
r
s
Charge max. (N)
course (mm)
0
0
500
1000
1500
2000
2500
3000
3500
DXD 300-BSY+ (-HS)
durable
brièvement
250
500
750
1000
1250
1500
99.824.27 1.7/04/2399.824.27 1.7/04/23
10/16 11/16
Français Français
Etendue de livraison
Motorisation avec ble silicone de 2,5 m. En
fonction du type de fenêtre, avec différentes kits de
console.
Utilisation conforme
- Motorisation à crémaillère pour l'ouverture et la
fermeture électromotorisées de fenêtres lourdes
et de vantaux dans les façades et les toits
- Tension de service 24 V DC
- Ingrable dans les ouvertures de sysmes
d'extraction de fumées, D+H Euro-RWA selon
DIN EN 12101-2, et utilisable pour la ventilation
quotidienne de pièces
- Uniquement pour montage à l'intérieur
Caractéristiques
- Électronique de synchronisation pilotée par
microprocesseur BSY+ pour un fonctionnement
synchronisé r et précis de 4 motorisations
maximum
- Programmation individuelle à l'aide du logiciel SCS
- Fonction EFC-Highspeed (fonctionnement rapide
en ouverture)
- Système de sécurité anti-coincement sur l'arête
de fermeture principale
Consignes de sécurité
Très basse tension de sécurité 24 V DC !
Ne pas raccorder directement au secteur !
- Seul un électricien qualifié est autorisé à procéder
au raccordement
- Risque d'écrasement des doigts dans la zone
accessible par les mains
- Tenir les personnes à l'écart de la zone de
mouvement de la motorisation
- Tenir les enfants à l'écart de la commande
- Respecter la charge de pression de la crémaillère!
- Uniquement placer la motorisation dans une pièce
sèche
- Uniquement pour montage à l'intérieur
- Employer un capteur de pluie en cas de risques de
pluie (par ex. lorsque le système est placé sur des
coupoles de toit ou des fenêtres de toit)
- Uniquement utiliser des pièces d'origine D+H non
modifiées
- Respecter la notice de montage du kit de console
Respecter les indications figurant sur l'étiquette
de sécurité rouge fournie !
DXD -BSY+ (-HS)DXD -BSY+ (-HS)
Charge de pression
La charge de pression maximale de la crémaillère ne correspond pas automatiquement à la force de pression
maximale de la motorisation !
Type DXD 150-BSY+ DXD 150-BSY+ HS DXD 300-BSY+ DXD 300-BSY+ HS
Alimentation 24 V DC, ±15 % 24 V DC, ±15 % 24 V DC, ±15 % 24 V DC, ±15 %
Courant nominale 1,4 A 2,5 A 2,5 A 5,0 A
Force nominale 1500 N 1500 N 3000 N 3000 N
Force de verrouillage nom. 1400 N (sans console) 2800 N (sans console)
Durée de vie >20 000 courses doubles
Durée d’enclenchement 30 % (manoeuvres de 10 minutes)
Corps Aluminium, thermolaqué, polycarbonate
Degré de protection IP 64 (“-W“ = IP 54)
Classe de température -15 ... +75 °C (VdS 2580: - 5 ... +75 °C)
sistance au feu 30 min / 300 °C
Emission niveau de
pression acoustique LpA ≤ 70 dB(A)
Course nominale * cf. plaquette signalétique
Fonctions additionnelles * Anti-coincement activé (3 courses de répétition)
* Programmable avec le logiciel SCS
Activité normale =
EFC fonctionnement rapide =
Système anti-pincement
Caractéristiques techniques
Toutes les forces
+ ca. 20 % de réserve
de coupure (en peu de temps)
Dans le sens « fermeture », la motorisation est équipée
d'une protection anti-pincement active pour l'arête de
fermeture principale. En cas de surcharge dans les
plages de fermeture 3 et 2, le moteur fonctionne dans le
sens « ouverture » pendant 10 secondes. Ensuite, il
reprend la direction « fermeture ». Si la fermeture se
révèle impossible après 3 tentatives, la motorisation
restera dans cette position. La motorisation est en outre
dotée d'une sécurité anti-coincement passive. La vitesse
de fermeture diminue à 5 mm/sec dans les plages de
fermeture 2 et 1.
Les forces au niveau des arêtes de
fermeture latérales peuvent être nettement
plus élevées. Risque d'écrasement des
doigts dans la zone accessible par les mains.
Arête de fermeture latérale
Arête de fermeture latérale
Arête de
fermeture principale
Ouvert
Forces
PF III
PF II
PF I
1500 N
1000 N
1000 N
800 N
3000 N
2000 N
1600 N
800 N
DXD 150-BSY+ (-HS) DXD 300-BSY+ (-HS)
FERMÉ
I
III
100 mm
20 mm
7,1 mm/s
5 mm/s
5 mm/s
~7,1 mm/s / ~8 mm/s (~17 mm/s)
II
selon la position de l'aimant
Vitesses de courses et forces
Charge max. (N)
course (mm)
0
250
500
750
1000
1250
1500
0
500
1000
1500
2000
2500
3000
3500
DXD 150-BSY+ (-HS)
durable
brièvement
Sur l'équipement de la version DXD 150-BSY+ (-HS), un
passement de la limite de charge de 1000 N jusqu'à
1500 N n'est admissible qu'à court terme.(par ex. pour
charger la neige ou en cas de forte sollicitation par le
vent (rafales de vent)). Course maximale admissible
pour une exposition à de telles charges : 1750 mm
Sur l'équipement de la version DXD 300-BSY+ (-HS), un
passement de la limite de charge de 2000 N jusqu'à
3000 N n'est admissible qu'à court terme.(par ex. pour
charger la neige ou en cas de forte sollicitation par le
vent (rafales de vent)). Course maximale admissible
pour une exposition à de telles charges : 1500 mm
AVERTISSEMENT
Lire tous les avertissements de sécurité, les
instructions, les illustrations et les spécifications
fournis avec cet produit.
Ne pas suivre les instructions énumérées ci-
dessous peut provoquer un choc électrique, un
incendie et/ou une blessure sérieuse.
Conserver tous les avertissements et toutes les
instructions pour pouvoir s'y reporter
ultérieurement.
Charge max. (N)
course (mm)
0
0
500
1000
1500
2000
2500
3000
3500
DXD 300-BSY+ (-HS)
durable
brièvement
250
500
750
1000
1250
1500
99.824.27 1.7/04/2399.824.27 1.7/04/23
10/16 11/16
Français Français
Etendue de livraison
Motorisation avec ble silicone de 2,5 m. En
fonction du type de fenêtre, avec différentes kits de
console.
Utilisation conforme
- Motorisation à crémaillère pour l'ouverture et la
fermeture électromotorisées de fenêtres lourdes
et de vantaux dans les façades et les toits
- Tension de service 24 V DC
- Ingrable dans les ouvertures de sysmes
d'extraction de fumées, D+H Euro-RWA selon
DIN EN 12101-2, et utilisable pour la ventilation
quotidienne de pièces
- Uniquement pour montage à l'intérieur
Caractéristiques
- Électronique de synchronisation pilotée par
microprocesseur BSY+ pour un fonctionnement
synchronisé r et précis de 4 motorisations
maximum
- Programmation individuelle à l'aide du logiciel SCS
- Fonction EFC-Highspeed (fonctionnement rapide
en ouverture)
- Système de sécurité anti-coincement sur l'arête
de fermeture principale
Consignes de sécurité
Très basse tension de sécurité 24 V DC !
Ne pas raccorder directement au secteur !
- Seul un électricien qualifié est autorisé à procéder
au raccordement
- Risque d'écrasement des doigts dans la zone
accessible par les mains
- Tenir les personnes à l'écart de la zone de
mouvement de la motorisation
- Tenir les enfants à l'écart de la commande
- Respecter la charge de pression de la crémaillère!
- Uniquement placer la motorisation dans une pièce
sèche
- Uniquement pour montage à l'intérieur
- Employer un capteur de pluie en cas de risques de
pluie (par ex. lorsque le système est placé sur des
coupoles de toit ou des fenêtres de toit)
- Uniquement utiliser des pièces d'origine D+H non
modifiées
- Respecter la notice de montage du kit de console
Respecter les indications figurant sur l'étiquette
de sécurité rouge fournie !
DXD -BSY+ (-HS)DXD -BSY+ (-HS)
Charge de pression
La charge de pression maximale de la crémaillère ne correspond pas automatiquement à la force de pression
maximale de la motorisation !
Type DXD 150-BSY+ DXD 150-BSY+ HS DXD 300-BSY+ DXD 300-BSY+ HS
Alimentation 24 V DC, ±15 % 24 V DC, ±15 % 24 V DC, ±15 % 24 V DC, ±15 %
Courant nominale 1,4 A 2,5 A 2,5 A 5,0 A
Force nominale 1500 N 1500 N 3000 N 3000 N
Force de verrouillage nom. 1400 N (sans console) 2800 N (sans console)
Durée de vie >20 000 courses doubles
Durée d’enclenchement 30 % (manoeuvres de 10 minutes)
Corps Aluminium, thermolaqué, polycarbonate
Degré de protection IP 64 (“-W“ = IP 54)
Classe de température -15 ... +75 °C (VdS 2580: - 5 ... +75 °C)
sistance au feu 30 min / 300 °C
Emission niveau de
pression acoustique LpA ≤ 70 dB(A)
Course nominale * cf. plaquette signalétique
Fonctions additionnelles * Anti-coincement activé (3 courses de répétition)
* Programmable avec le logiciel SCS
Activité normale =
EFC fonctionnement rapide =
Système anti-pincement
Caractéristiques techniques
Toutes les forces
+ ca. 20 % de réserve
de coupure (en peu de temps)
Dans le sens « fermeture », la motorisation est équipée
d'une protection anti-pincement active pour l'arête de
fermeture principale. En cas de surcharge dans les
plages de fermeture 3 et 2, le moteur fonctionne dans le
sens « ouverture » pendant 10 secondes. Ensuite, il
reprend la direction « fermeture ». Si la fermeture se
révèle impossible après 3 tentatives, la motorisation
restera dans cette position. La motorisation est en outre
dotée d'une sécurité anti-coincement passive. La vitesse
de fermeture diminue à 5 mm/sec dans les plages de
fermeture 2 et 1.
Les forces au niveau des arêtes de
fermeture latérales peuvent être nettement
plus élevées. Risque d'écrasement des
doigts dans la zone accessible par les mains.
Arête de fermeture latérale
Arête de fermeture latérale
Arête de
fermeture principale
Ouvert
Forces
PF III
PF II
PF I
1500 N
1000 N
1000 N
800 N
3000 N
2000 N
1600 N
800 N
DXD 150-BSY+ (-HS) DXD 300-BSY+ (-HS)
FERMÉ
I
III
100 mm
20 mm
7,1 mm/s
5 mm/s
5 mm/s
~7,1 mm/s / ~8 mm/s (~17 mm/s)
II
selon la position de l'aimant
Vitesses de courses et forces
Charge max. (N)
course (mm)
0
250
500
750
1000
1250
1500
0
500
1000
1500
2000
2500
3000
3500
DXD 150-BSY+ (-HS)
durable
brièvement
Sur l'équipement de la version DXD 150-BSY+ (-HS), un
passement de la limite de charge de 1000 N jusqu'à
1500 N n'est admissible qu'à court terme.(par ex. pour
charger la neige ou en cas de forte sollicitation par le
vent (rafales de vent)). Course maximale admissible
pour une exposition à de telles charges : 1750 mm
Sur l'équipement de la version DXD 300-BSY+ (-HS), un
passement de la limite de charge de 2000 N jusqu'à
3000 N n'est admissible qu'à court terme.(par ex. pour
charger la neige ou en cas de forte sollicitation par le
vent (rafales de vent)). Course maximale admissible
pour une exposition à de telles charges : 1500 mm
AVERTISSEMENT
Lire tous les avertissements de sécurité, les
instructions, les illustrations et les spécifications
fournis avec cet produit.
Ne pas suivre les instructions énumérées ci-
dessous peut provoquer un choc électrique, un
incendie et/ou une blessure sérieuse.
Conserver tous les avertissements et toutes les
instructions pour pouvoir s'y reporter
ultérieurement.
99.824.27 1.7/04/23
12/16 99.824.27 1.7/04/23 13/16
Français Français
Contrôle visuel :
Une seule motorisation maître peut être présente.
Le maître dispose de la dernière adresse,
conformément au nombre total de motorisations.
L'adresse est collée sur la motorisation.
Les motorisations esclaves sont numéroes
dans l'ordre décroissant.
Exemple : dans un groupe compo de 3 motori-
sations, il y a un maître, un esclave 1 et un esclave 2.
Attention : cet adressage vaut uniquement à l'état
à la livraison. EN effet, en cas de reconfiguration
avec le logiciel SCS, l'adressage défini en usine
n'existe plus !!
Câblage :
Le groupe est-il correctement câblé ?
Voir les schémas de câblage.
Remise à zéro :
Procéder à une remise à zéro.
Pour ce faire, le logiciel SCS ou l'aimant
spécial MAG502 sont requis.
Appeler le SAV de D+H :
Configuration des motorisations requise.
Le logiciel SCS est nécessaire.
Dépannage
Un groupe de synchronisation DXD-BSY+ (-HS) peut se
composer de maximum 4 motorisations qui
communiquent par le biais d'un bus. Chaque motorisation
possède sa propre adresse, laquelle est configurable à
l'aide du logiciel SCS. La dernière motorisation d'un
groupe de synchronisation est le maître (Master), lequel
pilote les autres motorisations, les esclaves (Slave). Les
différences de force entre les motorisations d'un groupe
de synchronisation sont équilibrées par une gulation
intelligente de position et de force. En cas de
dysfonctionnement ou de panne de l'une des
motorisations, toutes les autres sont sactivées.
Description des fonctions
DXD -BSY+ (-HS) DXD -BSY+ (-HS)
Brochage des fiches
Connexion: Page 14 - 15
Intervertir le câble d'alimentation
Mettre hors tension le moteur
Moindre 5mm
Moindre
60mm
X
X
Aimant FERME
NS
Aimant OUVRIR
N
S
Raccourcissement de la course
Déplacer à la position voulue les goupilles fendues
et les aimants à l'aide d'un outil approprié, par ex.
d'un tournevis. Respecter les espacements
minimums (60 mm et 5 mm) !
Le déplacement de l'aimant
"FERME” se termine par le
mouvement de
fermeture du moteur.
Nouvelle prise
D'origine par voie
automatique !
En cas de raccourcissement de
la course sur un groupe moteur
(2 à 4 moteurs), veiller à
déplacer l'ensemble des aimants
avec la même distance (tolérance totale sur
l'ensemble des moteurs : ± 2,5 mm) !
Avis X
Goupille fendue
Goupille fendue
2 aimants
Option -BRV
WH (Mot. a)
BN (Mot. b)
ORG (-HS)
YE (Data A)
GN (Data B)
GY (-BRV)
PK (n.c.)
Option -SGI/-SKS
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
GY (-SGI/SKS)
PK (+SGI/SKS)
Standard
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
Nettoyage et entretien
Avant toute intervention de maintenance, mettre
l'installation hors tension! L'inspection et l'entretien
doivent être effectués dans le respect des consignes
de D+H. Seules des pièces de rechange D+H
d'origine peuvent être employées.
En cas de présence de saletés, utiliser un chiffon doux
et sec.
Ne pas utiliser de détergents ou de solvants.
Les appareil électrique, ainsi que leurs accessoires,
batteries et emballages, doivent pouvoir suivre chacun
une voie de recyclage appropre. Ne jetez pas votre
appareil électroportatif avec les ordures nares !
Seulement pour les pays de l’Union Européenne :
Conforment à la directive européenne 2012/19/EU
relative aux déchets d’équipements électriques et
électroniques et sa réalisation dans les lois nationales,
les outils électroportatifs dont on ne peut plus se servir
doivent être sépas et suivre une voie de recyclage
appropriée.
Elimination des déchets
- Veiller à un rayon de pivotement du moteur
exempt d'obstacles sur toute la plage de course.
Sinon risque d'endommagement de la crémaillère
et de la suspension.
- La motorisation est réglée en usine. En cas de
modification de l'état à la livraison (par ex. sortir un
moteur d'un kit ou l'intégrer dans un autre kit), les
motorisations doivent être reprogrammées avec
le logiciel SCS.
- Utiliser seulement des moteurs de puissance
identique.
- Veiller à une répartition uniforme des charges
sur l'ensemble des moteurs.
Informations sur le montage
Déclaration de conformité
Nous déclarons sous notre propre responsabilité que
le produit décrit sous Caractéristiques tech-niques est
en conformité avec les réglementations suivants :
2014/30/EU, 2011/65/EU
S.I. 2016/1091, S.I. 2012/3032
Dossier technique auprès de :
D+H Mechatronic AG, D-22949 Ammersbek
Dirk Dingfelder Maik Schmees
CEO CTO
24.10.2022
Option -SA-SZ
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
GY (-SZ)
GN (-SZ)
PK (-SA)
YE (-SA)
WH (n.c.)
BN (n.c.)
OG (n.c.)
second câble
de raccordement
max. 48V / 1A
r
s
99.824.27 1.7/04/23
12/16 99.824.27 1.7/04/23 13/16
Français Français
Contrôle visuel :
Une seule motorisation maître peut être présente.
Le maître dispose de la dernière adresse,
conformément au nombre total de motorisations.
L'adresse est collée sur la motorisation.
Les motorisations esclaves sont numéroes
dans l'ordre décroissant.
Exemple : dans un groupe compo de 3 motori-
sations, il y a un maître, un esclave 1 et un esclave 2.
Attention : cet adressage vaut uniquement à l'état
à la livraison. EN effet, en cas de reconfiguration
avec le logiciel SCS, l'adressage défini en usine
n'existe plus !!
Câblage :
Le groupe est-il correctement câblé ?
Voir les schémas de câblage.
Remise à zéro :
Procéder à une remise à zéro.
Pour ce faire, le logiciel SCS ou l'aimant
spécial MAG502 sont requis.
Appeler le SAV de D+H :
Configuration des motorisations requise.
Le logiciel SCS est nécessaire.
Dépannage
Un groupe de synchronisation DXD-BSY+ (-HS) peut se
composer de maximum 4 motorisations qui
communiquent par le biais d'un bus. Chaque motorisation
possède sa propre adresse, laquelle est configurable à
l'aide du logiciel SCS. La dernière motorisation d'un
groupe de synchronisation est le maître (Master), lequel
pilote les autres motorisations, les esclaves (Slave). Les
différences de force entre les motorisations d'un groupe
de synchronisation sont équilibrées par une gulation
intelligente de position et de force. En cas de
dysfonctionnement ou de panne de l'une des
motorisations, toutes les autres sont sactivées.
Description des fonctions
DXD -BSY+ (-HS) DXD -BSY+ (-HS)
Brochage des fiches
Connexion: Page 14 - 15
Intervertir le câble d'alimentation
Mettre hors tension le moteur
Moindre 5mm
Moindre
60mm
X
X
Aimant FERME
NS
Aimant OUVRIR
N
S
Raccourcissement de la course
Déplacer à la position voulue les goupilles fendues
et les aimants à l'aide d'un outil approprié, par ex.
d'un tournevis. Respecter les espacements
minimums (60 mm et 5 mm) !
Le déplacement de l'aimant
"FERME” se termine par le
mouvement de
fermeture du moteur.
Nouvelle prise
D'origine par voie
automatique !
En cas de raccourcissement de
la course sur un groupe moteur
(2 à 4 moteurs), veiller à
déplacer l'ensemble des aimants
avec la même distance (tolérance totale sur
l'ensemble des moteurs : ± 2,5 mm) !
Avis X
Goupille fendue
Goupille fendue
2 aimants
Option -BRV
WH (Mot. a)
BN (Mot. b)
ORG (-HS)
YE (Data A)
GN (Data B)
GY (-BRV)
PK (n.c.)
Option -SGI/-SKS
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
GY (-SGI/SKS)
PK (+SGI/SKS)
Standard
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
Nettoyage et entretien
Avant toute intervention de maintenance, mettre
l'installation hors tension! L'inspection et l'entretien
doivent être effectués dans le respect des consignes
de D+H. Seules des pièces de rechange D+H
d'origine peuvent être employées.
En cas de présence de saletés, utiliser un chiffon doux
et sec.
Ne pas utiliser de détergents ou de solvants.
Les appareil électrique, ainsi que leurs accessoires,
batteries et emballages, doivent pouvoir suivre chacun
une voie de recyclage appropre. Ne jetez pas votre
appareil électroportatif avec les ordures nares !
Seulement pour les pays de l’Union Européenne :
Conforment à la directive européenne 2012/19/EU
relative aux déchets d’équipements électriques et
électroniques et sa réalisation dans les lois nationales,
les outils électroportatifs dont on ne peut plus se servir
doivent être sépas et suivre une voie de recyclage
appropriée.
Elimination des déchets
- Veiller à un rayon de pivotement du moteur
exempt d'obstacles sur toute la plage de course.
Sinon risque d'endommagement de la crémaillère
et de la suspension.
- La motorisation est réglée en usine. En cas de
modification de l'état à la livraison (par ex. sortir un
moteur d'un kit ou l'intégrer dans un autre kit), les
motorisations doivent être reprogrammées avec
le logiciel SCS.
- Utiliser seulement des moteurs de puissance
identique.
- Veiller à une répartition uniforme des charges
sur l'ensemble des moteurs.
Informations sur le montage
Déclaration de conformité
Nous déclarons sous notre propre responsabilité que
le produit décrit sous Caractéristiques tech-niques est
en conformité avec les réglementations suivants :
2014/30/EU, 2011/65/EU
S.I. 2016/1091, S.I. 2012/3032
Dossier technique auprès de :
D+H Mechatronic AG, D-22949 Ammersbek
Dirk Dingfelder Maik Schmees
CEO CTO
24.10.2022
Option -SA-SZ
WH (Mot. a)
BN (Mot. b)
OG (-HS)
YE (Data A)
GN (Data B)
GY (-SZ)
GN (-SZ)
PK (-SA)
YE (-SA)
WH (n.c.)
BN (n.c.)
OG (n.c.)
second câble
de raccordement
max. 48V / 1A
r
s
99.824.27 1.7/04/2399.824.27 1.7/04/23
14/16 15/16
Deutsch / English / Français Deutsch / English / Français
* nicht bei / not in case of / pas pour : GVL 8x0x-E/ -K/ -M
** Gegen Kurzschluss sichern / protect against short circuit / Protéger contre les courts-circuits
*** Bei Anschluss an D+H RWA Zentralen mit E/HS Leitungsüberwachung /
In case of connection to D+H SHEV control panels with E/HS line monitoring /
En cas de raccordement à des centrales D+H RWA, avec une surveillance des lignes E/HS
**** Kabel gemäß D+H Kabelverlegetabelle (siehe Gebrauchsanleitung der Zentrale) /
Cable acc. to D+H table for layout of cables (see instructions for use of control panel) /
Câble selon le tableau de pose de câbles D+H (cf. le mode d'emploi de la centrale)
Anschluss / Connection / Connexion
?
12345
L
6
N–
7
ZA E/X ab
LT
Gruppe / Group / Groupe
Überwachung /
Monitoring /
Surveillance*
Mot. a
Mot. b
MOT
(BK)
(BK)
(OG)
2x47kW
Endmodul
Terminal module
Module terminal
EM 47 K *
(WH)
(BN)
(OG)
(YE)
(GN)
Mot. a
Mot. b
HS
Data a
Data b
DXD-BSY+
Master 1
Abzweigdose / Junction box / Boîte de dérivation
****
***
**
DXD -BSY+ (-HS)DXD -BSY+ (-HS)
Anschluss / Connection / Connexion
?
123 4 5
L
6
N–
7
ZA E/X ab
LT
Gruppe / Group / Groupe
Überwachung /
Monitoring /
Surveillance*
Mot. a
Mot. b
MOT
(BK)
(BK)
(OG)
2x47kW
Endmodul
Terminal module
Module terminal
EM 47 K *
(WH)
(WH)
(BN)
(BN)
(OG)
(OG)
(YE)
(YE)
(GN)
(GN)
Mot. a
Mot. a
Mot. b
Mot. b
HS
HS
Data a
Data a
Data b
Data b
Slave 1
Master 2
Abzweigdose / Junction box / Boîte de dérivation
****
***
**
**
zur Zentrale /
to control panel /
vers la centrale
(WH) weiss / white / blanc
(BN) braun / brown / brun
(OG) orange / orange / orange
(YE) gelb / yellow / jaune
(GN) grün / green / vert
(PK) rosa / pink / rose
(GY) grau / grey / gris
**
DXD-BSY+
DXD-BSY+
**
zur Zentrale /
to control panel /
vers la centrale
Mot. b
(BN)
Mot. a
(WH)
Normalbetrieb
Normal mode
Activité normale
RWA- Schnelllauf
SHEV- fast running
EFC fonctionnement rapide
High-Speed
***
High-Speed
High-Speed
High-Speed
***
High-Speed
High-Speed
Mot. b
(BN)
Mot. a
(WH)
99.824.27 1.7/04/2399.824.27 1.7/04/23
14/16 15/16
Deutsch / English / Français Deutsch / English / Français
* nicht bei / not in case of / pas pour : GVL 8x0x-E/ -K/ -M
** Gegen Kurzschluss sichern / protect against short circuit / Protéger contre les courts-circuits
*** Bei Anschluss an D+H RWA Zentralen mit E/HS Leitungsüberwachung /
In case of connection to D+H SHEV control panels with E/HS line monitoring /
En cas de raccordement à des centrales D+H RWA, avec une surveillance des lignes E/HS
**** Kabel gemäß D+H Kabelverlegetabelle (siehe Gebrauchsanleitung der Zentrale) /
Cable acc. to D+H table for layout of cables (see instructions for use of control panel) /
Câble selon le tableau de pose de câbles D+H (cf. le mode d'emploi de la centrale)
Anschluss / Connection / Connexion
?
12345
L
6
N–
7
ZA E/X ab
LT
Gruppe / Group / Groupe
Überwachung /
Monitoring /
Surveillance*
Mot. a
Mot. b
MOT
(BK)
(BK)
(OG)
2x47kW
Endmodul
Terminal module
Module terminal
EM 47 K *
(WH)
(BN)
(OG)
(YE)
(GN)
Mot. a
Mot. b
HS
Data a
Data b
DXD-BSY+
Master 1
Abzweigdose / Junction box / Boîte de dérivation
****
***
**
DXD -BSY+ (-HS)DXD -BSY+ (-HS)
Anschluss / Connection / Connexion
?
123 4 5
L
6
N–
7
ZA E/X ab
LT
Gruppe / Group / Groupe
Überwachung /
Monitoring /
Surveillance*
Mot. a
Mot. b
MOT
(BK)
(BK)
(OG)
2x47kW
Endmodul
Terminal module
Module terminal
EM 47 K *
(WH)
(WH)
(BN)
(BN)
(OG)
(OG)
(YE)
(YE)
(GN)
(GN)
Mot. a
Mot. a
Mot. b
Mot. b
HS
HS
Data a
Data a
Data b
Data b
Slave 1
Master 2
Abzweigdose / Junction box / Boîte de dérivation
****
***
**
**
zur Zentrale /
to control panel /
vers la centrale
(WH) weiss / white / blanc
(BN) braun / brown / brun
(OG) orange / orange / orange
(YE) gelb / yellow / jaune
(GN) grün / green / vert
(PK) rosa / pink / rose
(GY) grau / grey / gris
**
DXD-BSY+
DXD-BSY+
**
zur Zentrale /
to control panel /
vers la centrale
Mot. b
(BN)
Mot. a
(WH)
Normalbetrieb
Normal mode
Activité normale
RWA- Schnelllauf
SHEV- fast running
EFC fonctionnement rapide
High-Speed
***
High-Speed
High-Speed
High-Speed
***
High-Speed
High-Speed
Mot. b
(BN)
Mot. a
(WH)
99.824.27 1.7/04/23
ohne Tubus /
without tube /
sans tube
182 mm
101 mm
8,5 mm
23 mm
30 mm
36 mm
7 mm
11 mm
84 mm
88 mm
187
mit Tubus /
with tube /
avec tube
Hub + 209 mm
Hub + 240,5 mm
Hub + 206 mm
Hub + 226 mm
38 mm
Ø 10 mm
Abmessungen / Dimensions / Dimensions
D+H Mechatronic AG
Georg-Sasse-Str. 28-32
, Germany22949 Ammersbek
: +49 239Tel. 40-605 65
: +49Fax 40-605 65 254
www.dh-partner.com
© 2022 D+H Mechatronic AG, Ammersbek
Technische Änderungen vorbehalten /
Rights to technical modifications reserved /
Sous réserve de modifications techniques /
100 % Recyclingpapier / Recycled paper / Papier recyclé
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

D+H DXD 150-BSY+ Mode d'emploi

Taper
Mode d'emploi