Whirlpool UXT5530AAS Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation
30" AND 36" (76.2 AND 91.4 CM) RANGE HOOD
Installation Instructions and Use & Care Guide
HOTTE DE CUISINIÈRE
DE 30" ET 36" (76,2 ET 91,4 CM)
Instructions d’installation et Guide d’utilisation et d’entretien
Table of Contents/Table des matières .....................................2
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONL
Y.
IMPOR
TANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISA
TION RÉSIDENTIELLE UNIQUEMENT
.
LI3VQE/W10274302F
2
TABLE OF CONTENTS TABLE DES MATIÈRES
RANGE HOOD SAFETY
You can be killed or seriously injured if you don't immediately
You
can be killed or seriously injured if you don't
follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
State of California Proposition 65 Warnings:
WARNING: This product contains one or more chemicals known to the State of California to cause cancer.
WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other
reproductive harm.
RANGE HOOD SAFETY .................................................................2
INSTALLATION REQUIREMENTS .................................................3
Tools and Parts ............................................................................. 3
Location Requirements ................................................................4
Venting Requirements ..................................................................5
Electrical Requirements ...............................................................6
INSTALLATION INSTRUCTIONS ...................................................7
Prepare Location ..........................................................................7
Install Range Hood ....................................................................... 9
Complete Installation .................................................................10
RANGE HOOD USE ......................................................................10
Range Hood Controls ................................................................11
RANGE HOOD CARE ...................................................................11
Cleaning .....................................................................................11
WIRING DIAGRAM .......................................................................12
ASSISTANCE OR SERVICE .........................................................13
In the U.S.A. ...............................................................................13
In Canada ...................................................................................13
Accessories ................................................................................13
WARRANTY ..................................................................................14
SÉCURITÉ DE LA HOTTE DE CUISINIÈRE ...............................15
EXIGENCES D’INSTALLATION ...................................................17
Outils et pièces ...........................................................................17
Exigences d’emplacement .........................................................17
Exigences concernant l’évacuation ...........................................18
Spécifications électriques ..........................................................20
INSTRUCTIONS D’INSTALLATION .............................................21
Préparation de l’emplacement ...................................................21
Installation de la hotte ................................................................22
Achever l’installation ..................................................................24
UTILISATION DE LA HOTTE .......................................................24
Range Hood Controls ................................................................24
ENTRETIEN DE LA HOTTE .........................................................25
Nettoyage ...................................................................................25
SCHÉMA DE CÂBLAGE ...............................................................26
ASSISTANCE OU SERVICE .........................................................27
Au Canada ..................................................................................27
Accessoires ................................................................................27
GARANTIE .....................................................................................27
3
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting
installation. Read and follow the instructions provided
with any tools listed here.
Tools needed
Drill
1
1
/
4
" (3 cm) drill bit
1
/
8
" (3 mm) drill bit for pilot holes
Pencil
Wire stripper or utility knife
Tape measure or ruler
Caulking gun and weatherproof caulking compound
Flat-blade screwdriver
Phillips screwdriver
For vented installations, you also need:
Saber or keyhole saw
Vent clamps
Metal snips
Compass or 8" (20.3 cm) circle template
Parts supplied
Remove parts from package. Check that all parts are included.
2 - Metal filters
6 - 4.5 x 13 mm mounting screws
3 - 4 x 8 mm damper screws
3
1
/
4
" x 10" (8.3 x 25.4 cm) damper/vent connector
4 - 5 x 45 mm screws
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
4
4 - 8 x 40 mm wall anchors
Recirculating kit
Charcoal filters for non-vented (recirculating) installations.
See the “Assistance or Service” section to order
replacement filters.
Parts needed
For vented installations:
3
1
/
4
" x 10" (8.3 x 25.4 cm) or 6" (15.2 cm) or larger
round metal venting
6" (15.2 cm) or larger round damper, if using
6" (15.2 cm) or larger round vent system
3
1
/
4
" x 10" (8.3 x 25.4 cm) to 6" (15.2 cm) or larger
diameter transition piece if using 6" (15.2 cm) or
larger diameter round vent system.
For cabinets with recessed bottoms:
Two 2" (5.1 cm) wide filler strips. Length and
thickness determined by recess dimensions.
Four flat-head wood screws or machine screws
with washers and nuts (to attach filler strips).
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
It is the installer’s responsibility to comply with installation
clearances specified on the model/serial/rating plate.
The model/serial/rating plate is located inside the range
hood on the left wall.
Range hood location should be away from strong draft
areas, such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance. Consult the
cooktop/range manufacturer installation instructions before
making any cutouts.
Grounded electrical outlet is required. See “Electrical
Requirements” section.
This range hood is recommended for use with cooktops
with a maximum total rating of 65,000 BTUs or less.
The hood is factory-set for vented installations.
For non-vented (recirculating) installations, the
Recirculation Kit is included. See the “Assistance
or Service” section to order Replacement Charcoal
Filters Part Number W10272068.
All openings in ceiling and wall where range hood
will be installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title
24 CFR, Part 328 (formerly the Federal Standard for Mobile
Home Construction and Safety, title 24, HUD, Part 280)
or when such standard is not applicable, the standard for
Manufactured Home Installation 1982 (Manufactured Home
Sites, Communities and Setups) ANSI A225.1/NFPA 501A,
or latest edition, or with local codes.
Product Dimensions
Installation Clearances
2"
(5.1 cm)
12"
(30.5 cm)
9"
(22.9 cm)
A
B
C
D
E
A. 18" (45.7 cm) min. clearance - upper cabinet to countertop
B. 24" (61 cm) min. for electric cooking surfaces
27" (68.6 cm) min. for gas cooking surfaces
30" (76.2 cm) suggested max. - bottom of range hood
to cooking surface
C. 30" or 36” (76.2 cm or 91.4 cm) min. cabinet opening width
D. 13" (33 cm) cabinet depth
E. 36" (91.4 cm) base cabinet height
5
Venting Requirements
(Vented Models Only)
Vent system must terminate to the outdoors,
except for non-vented (recirculating) installations.
Do not terminate the vent system in an attic or
other enclosed area.
Do not use a 4" (10.2 cm) laundry-type wall cap.
Use a 6" (15.2 cm) or larger round metal vent or a
3
1
/
4
" x 10" (8.3 x 25.4 cm) rectangular metal vent.
Rigid metal vent is recommended. Plastic or metal
foil vent is not recommended.
The length of vent system and number of elbows should
be kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61 cm) of straight
vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps to seal all joints in the vent system.
The vent system must have a damper. If roof or wall cap has
a damper, do not use damper supplied with the range hood.
Use caulking to seal exterior wall or roof opening
around the cap.
Cold Weather Installations
An additional back draft damper should be installed to minimize
backward cold air flow and a thermal break should be installed
to minimize conduction of outside temperatures as part of the
vent system. The damper should be on the cold air side of the
thermal break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup
air systems when using ventilation systems greater than
specified CFM of air movement. The specified CFM varies
from locale to locale. Consult your HVAC professional for
specific requirements in your area.
Venting Methods
Vent system can terminate either through the roof or wall.
Use 3
1
/
4
" x 10" (8.3 x 25.4 cm) with a maximum vent length
of 35 ft (10.7 m) or 6" (15.2 cm) or larger round vent with a
maximum length of 50 ft (15.2 m) for vent system.
NOTE: Flexible vent is not recommended. Flexible vent
creates back pressure and air turbulence that gently reduces
performance.
Roof Venting Wall Venting
A
B
D
C
E
A
B
C
D
E
A. 6" (15.2 cm) or larger round
vent or a 3
1
/
4
" x 10" (8.3 x
25.4 cm) rectangular vent
through roof
B. Round vent: use 6" (15.2 cm)
or larger round damper
(purchased separately)
C. Round vent: use 3
1
/
4
" x 10"
(8.3 x 25.4 cm) to 6" (15.2 cm)
or larger diameter transition
piece (purchased separately)
D. 24" to 30" (61 to 76.2 cm)
above electric cooking surface
27" to 30" (68.6 to 76.2 cm)
above gas cooking surface
E. Roof cap
A. 6" (15.2 cm) or larger round
vent or a 3
1
/
4
" x 10" (8.3 x
25.4 cm) rectangular vent
through the wall
B. Round vent: use 3
1
/
4
" x 10"
(8.3 x 25.4 cm) to 6" (15.2 cm)
or larger diameter transition
piece (purchased separately)
C. 3
1
/
4
" x 10" (8.3 x 25.4 cm)
through the wall
D. 24" to 30" (61 to 76.2 cm)
above electric cooking surface
27" to 30" (68.6 to 76.2 cm)
above gas cooking surface
E. Wall cap
Calculating Vent System Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
6" (15.2 cm) or Larger Round Vent System
Vent Piece Round
45° elbow 2.5 ft (0.8 m)
90° elbow 5 ft (1.5 m)
6" (15.2 cm) or larger wall cap 0 ft (0 m)
3
1
/
4
" x 10" (8.3 cm x 25.4 cm)
to 6" (15.2 cm) or larger
4.5 ft (1.4 m)
3
1
/
4
" x 10" (8.3 cm x 25.4 cm) to
6" (15.2 cm) or larger 90° elbow
5 ft (1.5 m)
6
Example vent system
Maximum Recommended Length = 50 ft (15.2 m)
1 - 90° elbow = 5 ft (1.5 m)
1 - wall cap = 0 ft (0 m)
8 ft (2.4 m) straight = 8 ft (2.4 m)
Length of 6" (15.2 cm) system = 13 ft (3.9 m)
3
1
/
4
" x 10" (8.3 cm x 25.4 cm) Vent System
Vent Piece
3
1
/
4
" x 10"
(8.3 cm x 25.4 cm)
90° elbow
5 ft (1.5 m)
3
1
/
4
" x 10"
(8.3 cm x 25.4 cm)
flat elbow
12 ft (3.7 m)
3
1
/
4
" x 10"
(8.3 cm x 25.4 cm)
wall cap
0 ft (0 m)
Example vent system
Maximum Recommended Length = 35 ft (10.7 m)
1 - 90° elbow = 5 ft (1.5 m)
8 ft (2.4 m) straight = 8 ft (2.4 m)
1 - wall cap = 0 ft (0 m)
Length of 3
1
/
4
" x 10"
(8.3 cm x 25.4 cm) system
= 13 ft (3.9 m)
Electrical Requirements
IMPORTANT: The range hood must be electrically grounded
in accordance with local codes and ordinances, or in the
absence of local codes, with the National Electrical Code,
ANSI/NFPA 70 (latest edition) or Canadian Electrical Code,
CSA C22.1 No. 0-M91 (latest edition).
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine
that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
A 120 volt, 60 Hz, AC only, 15- or 20-amp, fused
electrical circuit is required. A time-delay fuse or circuit
breaker is also recommended. It is recommended that a
separate circuit serving only this range hood be provided.
This range hood is equipped with a power supply
cord having a 3 prong grounding plug.
To minimize possible shock hazard, the cord must be
plugged into a mating, 3 prong, grounding-type outlet,
grounded in accordance with local codes and ordinances.
If a mating outlet is not available, it is the personal
responsibility and obligation of the customer to have the
properly grounded outlet installed by a qualified electrician.
Wall cap
90˚ elbo
w
2 ft (0.6 m)
6 ft (1.8 m)
Wall cap
3
¹⁄₄
" x 10"
(8.3 x 25.4 cm)
elbow
2 ft
(0.6 m)
6 ft (1.8 m)
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
7
The grounded 3 prong outlet is to be located inside the
cabinet above the range hood at a maximum distance of
33
7
/
16
" (85 cm) from where the power cord exits the hood.
INSTALLATION INSTRUCTIONS
Prepare Location
NOTE: For vented installations, it is recommended that
the vent system be installed before hood is installed.
Before making cutouts, make sure there is proper
clearance within the ceiling or wall for exhaust vent.
1. For vented installations, determine which venting
method to use: roof or wall.
2. Select a flat surface for assembling the range hood.
Place covering over that surface.
3. Using 2 or more people, lift the range hood and set
it upside down onto covered surface.
4. If cabinet has recessed bottom, add wood filler strips
on each side. Install screws to attach filler strips in
locations shown.
Determine Wiring Hole Location
Cut only one 1
1
/
4
" (3.2 cm) diameter wiring access hole.
See Step 2 for wiring hole location instructions.
1. Determine and clearly mark a vertical centerline on the
wall and cabinet in the area the vent opening will be made.
2. To wire through top:
Mark a line distance “A” from the left of the centerline
on the underside of the cabinet. Mark the point on this
line that is 2" (5.1 cm) from back wall. Drill a 1
1
/
4
" (3.2 cm)
diameter hole through the cabinet at this point.
33
⁷⁄₁₆" (85 cm)
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
For a grounded, cord-connected range hood:
This range hood must be grounded. In the event of an
electrical short circuit, grounding reduces the risk of electric
shock by providing an escape wire for the electric current.
This range hood is equipped with a cord having a grounding
wire with a grounding plug. The plug must be plugged into
an outlet that is properly installed and grounded.
WARNING: Improper grounding can result in a risk of
electric shock.
Consult a qualified electrician if the grounding instructions
are not completely understood, or if doubt exists as to
whether the range hood is properly grounded.
Do not use an extension cord. If the power supply cord is too
short, have a qualified electrician install an outlet near the
range hood.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
Cabinet
bottom
Wall
3" (7.6 cm)
Wood filler strips
(recessed cabinet
bottoms only)
3" (7.6 cm)
A
A. Centerline
Centerline
2" (5.1 cm)
from wall,
not cabinet
frame
A
A. 12" (30.5 cm)
8
Style 1 - Cut Openings for 3
1
/
4
" x 10"
(8.3 cm x 25.4 cm) Rectangular Vent System
Roof Venting
To make a 4
1
/
4
" x 10
1
/
2
" (10.8 cm x 26.7 cm) rectangular
cutout on the underside of cabinet top and bottom:
1. Mark lines
1
/
2
" (1.3 cm) and 4
3
/
4
" (12.1 cm) from the
back wall on the centerline of the underside of cabinet.
2. Mark lines 5
1
/
4
" (13.3 cm) to the right and left
of the centerline on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular
opening for vent.
4. Repeat steps 1 through 3 for the underside
of the top of the cabinet.
Wall Venting
To make a 3
1
/
2
" x 10
1
/
2
" (8.9 cm x 26.7 cm) rectangle
in the wall:
1. Make 2 lines by measuring
3
/
8
" (9.5 mm) and
3
7
/
8
" (9.8 cm) down from underside of cabinet
and mark on the centerline on the back wall.
2. Mark lines 5
1
/
4
" (13.3 cm) to the right and left
of the centerline on the wall.
3. Use saber or keyhole saw to cut a rectangular
opening in the wall for the vent.
Style 2 - Cut Openings for 3
1
/
4
" x 10" (8.3 x 25.4 cm)
Rectangular Vent to Round Vent Transition
Roof Venting
To make a 4
1
/
4
" x 10
1
/
2
" (10.8 cm x 26.7 cm) rectangular
cutout on the underside of cabinet bottom:
1. Mark lines
1
/
2
" (1.3 cm) and 4
3
/
4
" (12.1 cm) from the
back wall on the centerline of the underside of cabinet.
2. Mark lines 5
1
/
4
" (13.3 cm) to the right and left
of the centerline on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular
opening for vent.
To make a circular vent opening on the underside
of the cabinet top:
1. Mark a centerline on the underside of the top of cabinet.
2. Mark a line 5" (12.7 cm) from the back wall on the
underside of the top of cabinet.
3. Use a compass or a circle template to draw a circle
with a diameter that is
1
/
4
" (6.4 mm) larger than the vent.
4. Use saber or keyhole saw to cut the circular vent opening.
Install Vent System
1. Install vent through the vent opening in upper cabinet or
wall. Complete venting system according to the selected
venting method. See “Venting Requirements” section.
2. Use caulking to seal exterior wall or roof opening
around the cap.
5¹/"
(13.3 cm)
5¹/"
(13.3 cm)
*4³⁄₄"
(12.1 cm)
*From wall, not cabinet frame
*¹⁄₂" (1.3 cm)
³⁄₈"
3⁷⁄₈"
Cabinet
front
(1.0 cm)
(9.8 cm)
5¹⁄₄"
(13.3 cm)
Centerline
5¹⁄₄"
(13.3 cm)
5¹/"
(13.3 cm)
5¹/"
(13.3 cm)
*4³⁄₄"
(12.1 cm)
*From wall, not cabinet frame
*¹⁄₂" (1.3 cm)
Circular vent opening
Cabinet
cutouts
*From wall, not
cabinet frame
*5"
(12.7 cm)
9
Install Range Hood
1. Remove the grease filters. See the “Range
Hood Care” section.
2. Remove mounting screws and lateral supports.
3. For vented installations:
Depending on your installation, remove either top
or rear rectangular vent knockout. If using round
vent, remove top rectangular knockout.
NOTE: Do not remove rectangular knockouts
if installation of range hood is to be non-venting
(recirculating).
Make sure damper pivot is nearest to top/back
edge of range hood.
Remove tape from damper flap.
NOTE: The exhaust adaptor/damper can be
installed up to 1" (2.5 cm) on either side of the
hood center to accommodate off-center ductwork.
If using rectangular vent, attach rectangular damper/vent
connectors to the range hood using sheet metal screws.
If using round vent, attach vent transition piece
(purchased separately) to range hood top using
sheet metal screws.
NOTE: If the wall cap is directly behind the vent
connector, the dampers in the connector and
wall cap must not interfere with each other.
Remove the vent connector damper if they interfere.
4. Lift the range hood up under cabinet and determine
final location by centering beneath cabinet. Mark on
the underside of cabinet the location of the 4 keyhole
mounting slots on the range hood. Set range hood
aside on a covered surface.
5. Use
1
/
8
" (3 mm) drill bit and drill 4 pilot holes as shown.
6. Install the 4 - #10 x
5
/
8
" mounting screws in pilot holes.
Leave about
1
/
4
" (6.4 mm) space between screw heads
and cabinet to slide range hood into place.
A
A
B
A. Lateral supports
B. Mounting screws
A
B
C
D
C
B
E
A. Vertical vent
B. Sheet metal screws
C. Hinge pin
D. Vent knockouts
E. Horizontal vent
A
A. Keyhole slot
A
A. Drill pilot hole
¹⁄₄"
(6.4 mm)
10
7. For non-vented (recirculating) installations:
Remove screws and rear support.
Remove the blower mounting screws. Push up on the
blower to detach the blower from the mounting plate.
Remove the vent knockout from the front mounting plate.
Rotate the blower and attach to front mounting
plate. Install the blower mounting screws.
Install charcoal filters. See the “Range Hood
Care” section.
8. Using 2 people, lift range hood into final position, feeding
electrical wire through wiring opening. Position the range
hood so that the large end of the keyhole slots are over
the screws. Then push the hood toward the wall so that
the screws are in the neck of the slots. Tighten mounting
screws to cabinet, making sure mounting screws are in
narrow neck of slots.
9. Check that damper, if used, rotates up and down freely.
10. Reinstall the rear support.
11. Replace the 2 lateral supports.
12. Replace filters. See the “Range Hood Care” section.
13. Plug 3 prong power cord into a grounded 3 prong outlet
located inside the cabinet above the range hood.
14. For Vented Installations Only:
Connect ventwork to hood. Seal joints with clamps
to make secure and airtight.
Complete Installation
1. Replace grease filters. See the “Range Hood Care” section.
2. Check the operation of the range hood fan and light.
See “Range Hood Use” section.
If range hood does not operate, check to see whether a
circuit breaker has tripped or a household fuse has blown.
Disconnect power and check wiring connections.
NOTE: To get the most efficient use from your new range
hood, read the “Range Hood Use” section.
RANGE HOOD USE
The range hood is designed to remove smoke, cooking
vapors and odors from the cooktop area. For best results,
start the hood before cooking and allow it to operate several
minutes after the cooking is complete to clear all smoke and
odors from the kitchen.
The hood controls are located on the center of the range hood.
A
A. Rear support
A
B
C
A. Front mounting plate knockout
B. Blower mounting screws
C. Blower
A
B
A. Front mounting plate
B. Blower mounting screws
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
A
B
C
D
A. Halogen lamp housings
B. Grease filter handle
C. Blower and light controls
D. Grease filter
11
Range Hood Controls
Operating the light
The On/Off light button controls both lights. Press once
for On and again for Off.
Operating the blower
The Blower Speed buttons turn the blower On and control
the blower speed and sound level for quiet operation. The
speed can be changed anytime during fan operation by
pressing the desired blower speed button.
The Blower Off button turns the blower Off.
RANGE HOOD CARE
Cleaning
IMPORTANT: Clean the hood and grease filters frequently
according to the following instructions. Replace grease
filters before operating hood.
Exterior Surfaces
To avoid damage to the exterior surface, do not use
steel wool or soap-filled scouring pads.
Always wipe dry to avoid water marks.
Cleaning Method:
Liquid detergent soap and water, or all-purpose cleanser
Wipe with damp soft cloth or nonabrasive sponge,
and then rinse with clean water and wipe dry.
Metal Grease Filters
1. Remove each filter by pulling the spring release handle
and then pulling down the filter.
2. Wash metal filters as needed in dishwasher
or hot detergent solution.
3. Reinstall the filter by making sure the spring release handles
are toward the front. Insert aluminum filter into upper track.
4. Push in spring release handle.
5. Push up on metal filter and release handle to latch into place.
6. Repeat steps 1 through 5 for the other filter.
Non-Vented (recirculating) Installation Filters
The charcoal filter is not washable. It should last up to six
months with normal use. Replace with Charcoal Filter Kit
Number W10272068.
To replace charcoal filter:
1. Cover the grille that covers the blower motor with the
charcoal filter so that the slots on the filter correspond
to the pins on the sides of the motor cover grille.
2. Turn the charcoal filter clockwise to lock it.
3. Repeat steps 1 through 2 on the other filter.
Replacing a Halogen Lamp
Turn off the range hood and allow the halogen lamp to cool.
To avoid damage or decreasing the life of the new lamp,
do not touch lamp with bare fingers. Replace lamp, using
tissue or wearing cotton gloves to handle lamp.
If new lights do not operate, make sure the lamps are inserted
correctly before calling service.
1. Disconnect power.
2. Use a flat-blade screwdriver and gently pry the
light cover loose.
3. Remove the lamp and replace with a 120-volt, 40-watt
maximum, halogen lamp made for a G-9 base.
4. Replace the light cover.
5. Reconnect power.
A
B
C
D
E
A. Blower speed maximum button
B. Blower speed medium button
C. Blower speed minimum button
D. Blower Off button
E. On/Off light button
A
A. Spring release handle
A
B
C
A. Charcoal filter
B. Pins
C. Blower motor
12
WIRING DIAGRAM
WH
RD
BK
GY
BR
YL
BK
RD
WH
YL
BR
WH
YL
RD
GY
YL/GN
YL/GN
BK
GY
Push button switch
Switch Operation
Position
Function
Off
No connection
Lamps
Low speed
Med speed
High speed
GY/YL
(M - La)
GY/WH
(L - 1)
GY/RD
(L - 2)
GY/BK
(L - 3)
YL
WH
BK
BK
WH
BU
YL
BU
WH
BK
GY
Motor Specifications
Power Supply
Frequency
Power Absorption
120 VAC
60 Hz
240 WH
Motor Resistance (Ohms)
BU-RD
BU-GY
BU-BK
BU-WH
Room
temperature
37.7
30.3
28.8
45.1
73.4°F (23°C)
WH
WH
WH
WH
YL/GN
YL/GN
YL/GN
SE13EB
M
V
1
5
23
46789
3
2
1
L
La
M
12.5uF
13
ASSISTANCE OR SERVICE
If you need service
Please refer to the warranty page in this manual.
If you need replacement parts
If you need to order replacement parts, we recommend that
you use only factory specified parts. Factory specified parts
will fit right and work right because they are made with the
same precision used to build every new appliance.
To locate factory specified replacement parts in your area,
call the following customer assistance telephone number
or your nearest designated service center.
In the U.S.A.
Call the Whirlpool Customer eXperience Center toll free:
1-800-253-1301 or visit our website at www.whirlpool.com.
Our consultants provide assistance with:
Scheduling of service. Whirlpool designated service
technicians are trained to fulfill the product warranty and
provide after-warranty service anywhere in the United States.
Features and specifications on our full line of appliances.
Referrals to local dealers.
Installation information.
Use and maintenance procedures.
Accessory and repair parts sales.
Specialized customer assistance (Spanish speaking,
hearing impaired, limited vision, etc.).
For further assistance
If you need further assistance, you can write to Whirlpool
Corporation with any questions or concerns at:
Whirlpool Brand Home Appliances
Customer eXperience Center
553 Benson Road
Benton Harbor, MI 49022-2692
Please include a daytime phone number in your correspondence.
In Canada
Call the Whirlpool Canada Customer eXperience Centre toll free:
1-800-807-6777, or visit our website at www.whirlpool.ca.
Our Consultants Provide Assistance With:
Scheduling of Service. Whirlpool designated service
technicians are trained to fulfill the product warranty
and provide after-warranty service anywhere in Canada.
Features and specifications on our full line of appliances.
Referrals to local dealers.
Use and maintenance procedures.
Accessory and repair parts sales.
For Further Assistance
If you need further assistance, you can write to Whirlpool
Canada with any questions or concerns at:
Whirlpool Brand Home Appliances
Customer eXperience Centre
200 - 6750 Century Ave.
Mississauga, Ontario L5N 0B7
Please include a daytime phone number in your correspondence.
Accessories
Replacement Charcoal Filter Kit (2 Pack of Filters)
(for non-vented installations only)
Order Part Number W10272068
3
1
/
4
" x 10" (8.3 x 25.4 cm) Makeup Air Kit
(consult local building codes)
Order Part Number W10446914
14
11/14
IF YOU NEED SERVICE:
1. Before contacting us to arrange service, please determine whether your product requires repair.
Some questions can be addressed without service. Please take a few minutes to review the
Troubleshooting or Problem Solver section of the Use and Care Guide, scan the QR code on
the right to access additional resources, or visit www.whirlpool.com/product_help.
2. All warranty service is provided exclusively by our authorized Whirlpool Service Providers.
In the U.S. and Canada, direct all requests for warranty service to:
Whirlpool Customer eXperience Center
In the U.S.A., call 1-800-253-1301. In Canada, call 1-800-807-6777.
If outside the 50 United States or Canada, contact your authorized Whirlpool dealer to determine whether another warranty applies.
WHIRLPOOL
®
MAJOR APPLIANCE
LIMITED WARRANTY
ATTACH YOUR RECEIPT HERE. PROOF OF PURCHASE IS
REQUIRED TO OBTAIN WARRANTY SERVICE.
Please have the following information available when you call the
Customer eXperience Center:
Name, address and telephone number
Model number and serial number
A clear, detailed description of the problem
Proof of purchase including dealer or retailer name and address
ONE YEAR LIMITED WARRANTY
WHAT IS COVERED WHAT IS NOT COVERED
For one year from the date
of purchase, when this major
appliance is installed, operated
and maintained according to
instructions attached to or
furnished with the product,
Whirlpool Corporation or
Whirlpool Canada LP (hereafter
“Whirlpool”) will pay for Factory
Specified Replacement Parts and
repair labor to correct defects in
materials or workmanship that
existed when this major appliance
was purchased, or at its sole
discretion replace the product. In
the event of product replacement,
your appliance will be warranted
for the remaining term of the
original unit’s warranty period.
YOUR SOLE AND EXCLUSIVE
REMEDY UNDER THIS LIMITED
WARRANTY SHALL BE PRODUCT
REPAIR AS PROVIDED HEREIN.
Service must be provided by a
Whirlpool designated service
company. This limited warranty
is valid only in the United States
or Canada and applies only when
the major appliance is used in the
country in which it was purchased.
This limited warranty is effective
from the date of original consumer
purchase. Proof of original
purchase date is required to obtain
service under this limited warranty.
1. Commercial, non-residential, multiple-family use, or use inconsistent with published user,
operator or installation instructions.
2. In-home instruction on how to use your product.
3. Service to correct improper product maintenance or installation, installation not in accordance
with electrical or plumbing codes or correction of household electrical or plumbing (i.e. house
wiring, fuses or water inlet hoses).
4. Consumable parts (i.e. light bulbs, batteries, air or water filters, preservation solutions, etc.).
5. Defects or damage caused by the use of non-genuine Whirlpool parts or accessories.
6. Conversion of products from natural gas or L.P. gas.
7. Damage from accident, misuse, abuse, fire, floods, acts of God or use with products not
approved by Whirlpool.
8. Repairs to parts or systems to correct product damage or defects caused by unauthorized
service, alteration or modification of the appliance.
9. Cosmetic damage including scratches, dents, chips, and other damage to the appliance finishes
unless such damage results from defects in materials and workmanship and is reported to
Whirlpool within 30 days.
10. Discoloration, rust or oxidation of surfaces resulting from caustic or corrosive environments
including but not limited to high salt concentrations, high moisture or humidity or exposure to
chemicals.
11. Food or medicine loss due to product failure.
12. Pick-up or delivery. This product is intended for in-home repair.
13. Travel or transportation expenses for service in remote locations where an authorized Whirlpool
servicer is not available.
14. Removal or reinstallation of inaccessible appliances or built-in fixtures (i.e. trim, decorative
panels, flooring, cabinetry, islands, countertops, drywall, etc.) that interfere with servicing,
removal or replacement of the product.
15. Service or parts for appliances with original model/serial numbers removed, altered or not easily
determined.
The cost of repair or replacement under these excluded circumstances shall be borne by the
customer.
DISCLAIMER OF IMPLIED WARRANTIES
IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR A
PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW. Some states and provinces do not
allow limitations on the duration of implied warranties of merchantability or fitness, so this limitation may not apply to you. This warranty gives
you specific legal rights, and you also may have other rights that vary from state to state or province to province.
DISCLAIMER OF REPRESENTATIONS OUTSIDE OF WARRANTY
Whirlpool makes no representations about the quality, durability, or need for service or repair of this major appliance other than the
representations contained in this warranty. If you want a longer or more comprehensive warranty than the limited warranty that comes with
this major appliance, you should ask Whirlpool or your retailer about buying an extended warranty.
LIMITATION OF REMEDIES; EXCLUSION OF INCIDENTAL AND CONSEQUENTIAL DAMAGES
YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR AS PROVIDED HEREIN.
WHIRLPOOL SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states and provinces do not allow the
exclusion or limitation of incidental or consequential damages, so these limitations and exclusions may not apply to you. This warranty gives
you specific legal rights, and you also may have other rights that vary from state to state or province to province.
www.whirlpool.com/product_help
15
SÉCURITÉ DE LA HOTTE DE CUISINIÈRE
Risque possible de décès ou de blessure grave si vous ne
suivez pas immédiatement les instructions.
Risque possible de décès ou de blessure grave si vous
ne suivez pas les instructions.
Tous les messages de sécurité vous diront quel est le danger potentiel et vous disent comment réduire le risque de blessure et
ce qui peut se produire en cas de non-respect des instructions.
Votre sécurité et celle des autres est très importante.
Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de
toujours lire tous les messages de sécurité et de vous y conformer.
AVERTISSEMENT
DANGER
Voici le symbole d’alerte de sécurité.
Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous
et à d’autres.
Tous les messages de sécurité suivront le symbole d’alerte de sécurité et le mot “DANGER” ou
“AVERTISSEMENT”. Ces mots signifient :
Avertissements de la proposition 65 de l'État de Californie :
AVERTISSEMENT : Ce produit contient au moins un produit chimique connu par l’État de Californie pour être à l’origine de
cancers.
AVERTISSEMENT : Ce produit contient au moins un produit chimique connu par l’État de Californie pour être à l’origine de
malformations et autres déficiences de naissance.
16
IMPORTANTES INSTRUCTIONS DE SÉCURITÉ
LIRE ET CONSERVER CES INSTRUCTIONS
AVERTISSEMENT : POUR RÉDUIRE LE RISQUE
D'INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES
CORPORELS, RESPECTER LES INSTRUCTIONS
SUIVANTES :
Utiliser cet appareil uniquement dans les applications
envisagées par le fabricant. Pour toute question, contacter
le fabricant.
Avant d'entreprendre un travail d'entretien ou de nettoyage,
interrompre l'alimentation de la hotte au niveau du tableau
de disjoncteurs, et verrouiller le tableau de disjoncteurs
pour empêcher tout rétablissement accidentel de
l'alimentation du circuit. Lorsqu'il n'est pas possible de
verrouiller le tableau de disjoncteurs, placer sur le tableau
de disjoncteurs une étiquette d'avertissement proéminente
interdisant le rétablissement de l'alimentation.
Tout travail d'installation ou câblage électrique doit être
réalisé par une personne qualifiée, dans le respect des
prescriptions de tous les codes et normes applicables, y
compris les codes du bâtiment et de protection contre les
incendies.
Ne pas faire fonctionner un ventilateur dont le cordon ou la
fiche est endommagé(e). Jeter le ventilateur ou le retourner
à un centre de service agréé pour examen et/ou réparation.
Une source d'air de débit suffisant est nécessaire pour le
fonctionnement correct de tout appareil à gaz (combustion
et évacuation des gaz à combustion par la cheminée), pour
qu'il n'y ait pas de reflux des gaz de combustion. Respecter
les directives du fabricant de l'équipement de chauffage et
les prescriptions des normes de sécurité - comme celles
publiées par la National Fire Protection Association (NFPA)
et l'American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), et les prescriptions des
autorités réglementaires locales.
Lors des opérations de découpage et de perçage dans un
mur ou un plafond, ne pas endommager les câblages
électriques et les canalisations qui peuvent s’y trouver.
Les ventilateurs d'évacuation doivent toujours décharger
l'air à l'extérieur.
MISE EN GARDE : Cet appareil est conçu uniquement
pour la ventilation générale. Ne pas l'utiliser pour l'extraction
de matières ou vapeurs dangereuses ou explosives.
MISE EN GARDE : Pour minimiser le risque d'incendie
et évacuer adéquatement les gaz, veiller à acheminer l'air
aspiré par un conduit jusqu'à l'extérieur - ne pas décharger
l'air aspiré dans un espace vide du bâtiment comme une
cavité murale, un plafond, un grenier, un vide sanitaire ou
un garage.
AVERTISSEMENT : POUR RÉDUIRE LE RISQUE
D'INCENDIE, UTILISER UNIQUEMENT DES CONDUITS
MÉTALLIQUES.
AVERTISSEMENT : POUR MINIMISER LE RISQUE
D'UN FEU DE GRAISSE SUR LA CUISINIÈRE :
Ne jamais laisser un élément de surface fonctionner à
puissance de chauffage maximale sans surveillance. Un
renversement/débordement de matière graisseuse pourrait
provoquer une inflammation et la génération de fumée.
Utiliser une puissance de chauffage moyenne ou basse
pour le chauffage d'huile.
Veiller à toujours faire fonctionner le ventilateur de la hotte
lors de la cuisson avec une puissance de chauffage élevée
ou lors de la cuisson d'un mets à flamber (à savoir crêpes
Suzette, cerise jubilée, steak au poivre flambé).
Nettoyer fréquemment les ventilateurs d'extraction. Veiller à
ne pas laisser la graisse s'accumuler sur les surfaces du
ventilateur ou des filtres.
Utiliser toujours un ustensile de taille appropriée. Utiliser
toujours un ustensile adapté à la taille de l'élément
chauffant.
AVERTISSEMENT : POUR RÉDUIRE LE RISQUE DE
DOMMAGES CORPORELS APRÈS LE DÉCLENCHEMENT
D'UN FEU DE GRAISSE SUR LA CUISINIÈRE, APPLIQUER
LES RECOMMANDATIONS SUIVANTES :
a
Placer sur le récipient un couvercle bien ajusté, une tôle à
biscuits ou un plateau métallique POUR ÉTOUFFER LES
FLAMMES, puis éteindre le brûleur. VEILLER À ÉVITER
LES BRÛLURES. Si les flammes ne s'éteignent pas
immédiatement, ÉVACUER LA PIÈCE ET APPELER LES
POMPIERS.
NE JAMAIS PRENDRE EN MAIN UN RÉCIPIENT
ENFLAMMÉ - vous risquez de vous brûler.
NE PAS UTILISER D'EAU, ni un torchon humide - ceci
pourrait provoquer une explosion de vapeur brûlante.
Utiliser un extincteur SEULEMENT si :
– Il s'agit d'un extincteur de classe ABC, dont on connaît le
fonctionnement.
– Il s'agit d'un petit feu encore limité à l'endroit où il s'est
déclaré.
– Les pompiers ont été contactés.
– Il est possible de garder le dos orienté vers une sortie
pendant l'opération de lutte contre le feu.
a
Recommandations tirées des conseils de sécurité en cas
d'incendie de cuisine publiés par la NFPA.
AVERTISSEMENT : Pour réduire le risque d'incendie
ou de choc électrique, ne pas utiliser ce ventilateur avec un
quelconque dispositif de réglage de la vitesse à semi-
conducteurs.
17
EXIGENCES D’INSTALLATION
Outils et pièces
Rassembler les outils et composants nécessaires avant
d’entreprendre l’installation. Lire et observer les instructions
fournies avec chacun des outils de la liste ci-dessous.
Outils nécessaires
Perceuse
1 foret de 1
1
/
4
" (3 cm)
Foret de
1
/
8
" (3 mm) pour avant-trous
Crayon
Pince à dénuder ou couteau utilitaire
Mètre-ruban ou règle
Pistolet à calfeutrage et composé de calfeutrage
résistant aux intempéries
Tournevis à lame plate
Tournevis Phillips
Pour une installation avec décharge à l’extérieur,
vous aurez également besoin de :
Scie sauteuse ou scie à guichet
Brides de conduit
Cisaille de ferblantier
Compas ou gabarit de diamètre 8" (20,3 cm)
Pièces fournies
Retirer les pièces de l’emballage. Vérifier que
toutes les pièces sont présentes.
2 - filtres métalliques
6 - vis de montage de 4,5 x 13 mm
3 - vis de clapet de 4 x 8 mm
Module clapet/connecteur de conduit de 3
1
/
4
" x 10"
(8,3 x 25,4 cm)
4 - vis de 5 x 45 mm
4 - vis d’ancrage mural de 8 x 40 mm
Ensemble de recyclage
Filtres à charbon - Installation sans décharge à l’extérieur
(recyclage). Pour commander des filtres à charbon de
rechange, voir la section “Assistance ou service”.
Pièces nécessaires
Installations avec décharge à l’extérieur :
Conduit métallique rond de 3
1
/
4
" x 10" (8,3 x 25,4 cm)
ou d’un diamètre de 6" (15,2 cm) ou plus
Clapet anti-reflux de 6" (15,2 cm) ou plus de diamètre,
pour utilisation avec un circuit d’évacuation de 6"
(15,2 cm) ou plus de diamètre
Raccord de transition de 3
1
/
4
" x 10" (8,3 x 25,4 cm) sur 6"
(15,2 cm) ou plus de diamètre pour utilisation avec circuit
d’évacuation d’un diamètre de 6" (15,2 cm) ou plus.
Pour placards avec cavité au fond :
Deux tringles d’appui de largeur 2" (5,1 cm). Longueur
et épaisseur selon les dimensions de l’encastrement.
Quatre vis à bois à tête plate ou vis à métaux avec
rondelles et écrous, pour la fixation des tringles d’appui.
Exigences d’emplacement
IMPORTANT : Observer les dispositions de tous
les codes et règlements en vigueur.
C’est à l’installateur qu’incombe la responsabilité de
respecter les distances de séparation exigées, spécifiées
sur la plaque signalétique de l’appareil. La plaque
signalétique est située à l’intérieur de la hotte, sur
la paroi gauche.
Installer la hotte de cuisinière à distance de toute zone
exposée à des courants d’air, comme fenêtres, portes
et bouches de chauffage.
Respecter les dimensions indiquées pour les ouvertures
à découper dans les placards; ces dimensions tiennent
compte des valeurs minimales des dégagements de
séparation. Avant d’effectuer des découpages, consulter
les instructions d’installation fournies par le fabricant de
la table de cuisson/cuisinière.
On doit disposer d’une prise de courant électrique reliée
à la terre. Voir la section “Spécifications électriques”.
Il est recommandé d’utiliser cette hotte avec une table de
cuisson dont la puissance totale ne dépasse pas 65 000 BTU.
La hotte a été configurée à l’usine pour une installation avec
décharge à l’extérieur. Pour une installation sans décharge
à l’extérieur (recyclage), l’ensemble de recyclage est inclus.
Voir la section “Assistance ou service” pour commander
un filtre à charbon de rechange (pièce n° W10272068).
Assurer l’étanchéité au niveau de chaque ouverture
découpée dans le plafond ou le mur pour l’installation
de la hotte de cuisinière.
Installation dans une résidence mobile
L’installation de cette hotte de cuisinière doit satisfaire aux
exigences de la norme Manufactured Home Construction
Safety Standards, Titre 24 CFR, partie 328 (anciennement
Federal Standard for Mobile Home Construction and Safety,
titre 24, HUD, partie 280); lorsque cette norme n’est pas
applicable, l’installation doit satisfaire aux critères de la plus
récente édition de la norme Manufactured Home Installation
1982 (Manufactured Home Sites, Communities and Setups)
ANSI A225.1/NFPA 501A, ou des codes et règlements locaux.
Dimensions du produit
2"
(5,1 cm)
12"
(30,5 cm)
9"
(22,9 cm)
18
Dégagements de séparation à respecter
Exigences concernant l’évacuation
(Uniquement pour modèles avec évacuation)
Le système d’évacuation doit décharger l’air à l’extérieur,
excepté pour les installations sans décharge à l’extérieur
(recyclage).
Ne pas terminer le conduit d’évacuation dans un grenier
ou dans un autre espace fermé.
Ne pas utiliser une bouche de décharge murale
de 4" (10,2 cm) normalement utilisée pour un
équipement de buanderie.
Utiliser un conduit métallique rond de 6" (15,2 cm) ou plus
de diamètre, ou un conduit métallique rectangulaire de 3
1
/
4
"
x 10" (8,3 cm x 25,4 cm). Un conduit en métal rigide est
recommandé. L’utilisation d’un conduit de plastique ou en
feuille métallique est déconseillée.
La longueur du système d’évacuation et le nombre
de coudes doit être réduit au minimum pour fournir
la meilleure performance.
Pour un fonctionnement efficace et silencieux :
Ne pas utiliser plus de trois coudes à 90°.
Veiller à ce qu’il y ait une section droite de conduit
de 24" (61,0 cm) au minimum entre deux coudes,
si on doit utiliser plus d’un raccord coudé.
Ne pas installer 2 coudes ensemble.
Au niveau de chaque jointure du conduit de décharge,
assurer l’étanchéité avec les brides de serrage pour conduit.
Le système d’évacuation doit comporter un clapet.
Si la bouche de décharge murale ou par le toit comporte
un clapet, ne pas utiliser le clapet fourni avec la hotte
de cuisinière.
Autour de la bouche de décharge à l’extérieur par
un mur ou par le toit, assurer l’étanchéité avec un
produit de calfeutrage.
Installations pour régions à climat froid
On doit installer un clapet anti-reflux additionnel à l’arrière
pour minimiser le reflux d’air froid, et incorporer un élément
d’isolation thermique pour minimiser la conduction de chaleur
par l’intermédiaire du conduit d’évacuation, de l’intérieur de
la maison à l’extérieur. Le clapet anti-reflux doit être placé du
côté air froid par rapport à l’élément d’isolation thermique.
L’élément d’isolation thermique doit être aussi proche que
possible de l’endroit où le système d’évacuation s’introduit
dans la partie chauffée de la maison.
Air d’appoint
Le code du bâtiment local peut exiger l’emploi d’un système
d’appoint d’air lors de l’emploi d’un ventilateur d’extraction
dont la capacité d’aspiration est supérieure à un débit (pieds
cubes par minute) spécifié. Le débit spécifié, pieds cubes par
minute, est variable d’une juridiction à une autre. Consulter
un professionnel des installations de chauffage ventilation/
climatisation au sujet des exigences spécifiques applicables
dans la juridiction locale.
Méthodes d’évacuation
La sortie à l’extérieur du circuit d’évacuation peut se faire
à travers le toit ou à travers un mur. Utiliser un conduit
rectangulaire de 3
1
/
4
" x 10" (8,3 cm x 25,4 cm) pour une
longueur effective maximale de circuit de 35 pi (10,7 m)
ou un conduit rond de 6" (15,2 cm) ou plus de diamètre pour
une longueur effective maximale de circuit de 50 pi (15,2 m).
REMARQUE : On déconseille l’emploi d’un conduit
flexible. Un conduit flexible peut susciter une rétro-pression
et des turbulences de l’air, ce qui réduit considérablement
la performance.
A
B
C
D
E
A. Dégagement min. de 18" (45,7 cm) entre le placard
supérieur et le plan de travail
B. 24" (61 cm) min. pour les surfaces de cuisson électriques
27" (68,6 cm) min. pour surfaces de cuisson au gaz
Distance maximale suggérée de 30" (76,2 cm) du bas
de la hotte à la surface de cuisson
C. Largeur minimale de l’ouverture du placard de 30"
ou 36" (76,2 ou 91,4 cm)
D. Profondeur de placard 13" (33 cm)
E. Hauteur de placard du bas 36" (91,4 cm)
19
Décharge à travers le toit Décharge à travers le mur
A
B
D
C
E
A
B
C
D
E
A. Conduit rond de diamètre 6"
(15,2 cm) ou plus ou conduit
rectangulaire de 3
1
/
4
" x 10"
(8,3 x 25,4 cm) à travers le toit
B. Conduit rond : utiliser un
clapet rond de 6" (15,2 cm)
ou plus de diamètre (achat
séparé)
C. Conduit rond : Utiliser un
raccord de transition de
3
1
/
4
" x 10” (8,3 x 25,4 cm)
sur 6" (15,2 cm) ou de plus
grande taille (achat séparé).
D. 24" à 30" (61 à 76,2 cm)
au-dessus de la surface
de cuisson électrique
27" à 30" (68,6 à 76,2 cm)
au-dessus de la surface
de cuisson au gaz
E. Bouche de décharge sur toit
A. Conduit de diamètre 6"
(15,2 cm) ou plus ou conduit
rectangulaire de 3
1
/
4
" x 10"
(8,3 x 25,4 cm) à travers le mur
B. Conduit rond : Utiliser un
raccord de transition de
3
1
/
4
" x 10" (8,3 x 25,4 cm)
sur 6" (15,2 cm) ou de plus
grande taille (achat séparé)
C. Sortie à travers le mur pour
conduit rectangulaire de
3
1
/
4
" x 10" (8,3 x 25,4 cm)
D. 24" à 30" (61 à 76,2 cm)
au-dessus de la surface
de cuisson électrique
27" à 30” (68,6 à 76,2 cm)
au-dessus de la surface
de cuisson au gaz
E. Bouche de décharge murale
Calcul de la longueur effective
du circuit d’évacuation
Pour calculer la longueur effective du circuit d’évacuation
nécessaire, additionner les longueurs équivalentes (pieds/
mètres) de tous les composants utilisés dans le système.
Système de décharge circulaire de 6" (15,2 cm) ou plus
Composant Conduit rond
Coude à 45° 2,5 pi (0,8 m)
Coude à 90° 5 pi (1,5 m)
Bouche de décharge murale
de 6" (15,2 cm) ou plus
0 pi (0 m)
3
1
/
4
" x 10" (8,3 cm x 25,4 cm)
sur 6" (15,2 cm) ou plus
4,5 pi (1,4 m)
Coude à 90° de 3
1
/
4
" x 10"
(8,3 cm x 25,4 cm) sur 6"
(15,2 cm) ou plus
5 pi (1,5 m)
Exemple de système de décharge
Longueur maximale recommandée = 50 pi (15,2 m)
1 - coude à 90° = 5 pi (1,5 m)
1 - bouche de décharge murale = 0 pi (0 m)
Section droite de 8 pi (2,4 m) = 8 pi (2,4 m)
Longueur du système de dia.
6" (15,2 cm)
= 13 pi (3,9 m)
Système de décharge de 3
1
/
4
" x 10" (8,3 cm x 25,4 cm)
Composant
Coude à 90° de 3
1
/
4
" x 10"
(8,3 cm x 25,4 cm)
5 pi (1,5 m)
Coude plat de 3
1
/
4
" x 10"
(8,3 cm x 25,4 cm)
12 pi (3,7 m)
Bouche de décharge murale de
3
1
/
4
" x 10" (8,3 cm x 25,4 cm)
0 pi (0 m)
Exemple de système de décharge
Longueur maximale recommandée = 35 pi (10,7 m)
1 - coude à 90° = 5 pi (1,5 m)
Section droite de 8 pi (2,4 m) = 8 pi (2,4 m)
1 - bouche de décharge murale = 0 pi (0 m)
Longueur du système de
3
1
/
4
" x 10" (8,3 cm x 25,4 cm)
= 13 pi (3,9 m)
Bouche de
décharge m
urale
coude à 90˚
2 pi (0,6 m)
6 pi (1,8 m)
Bouche de
décharge m
urale
Coude de 3
¹⁄₄
" x 10"
(8,3 x 25,4 cm)
2 pi (0,6 m)
6 pi (1,8 m)
20
Spécifications électriques
IMPORTANT : La hotte doit être correctement reliée à la
terre en conformité avec les codes et règlements locaux
en vigueur, ou en l’absence de tels codes, avec le National
Electrical Code, ANSI/NFPA 70 (dernière édition) ou le Code
canadien des installations électriques, CSA C22.1. No. 0-M91
(dernière édition).
Si les codes le permettent et si on utilise un conducteur
distinct de liaison à la terre, il est recommandé qu’un
électricien qualifié vérifie la qualité de la liaison à la terre.
Pour obtenir un exemplaire des normes des codes
ci-dessus, contacter :
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
Une alimentation de 120 volts, 60 Hz, CA seulement,
de 15 ou 20 ampères, protégée par un fusible est requise.
On recommande également d’utiliser un fusible ou un
disjoncteur temporisé. Il est recommandé de raccorder
la hotte sur un circuit distinct exclusif à cet appareil.
Cette hotte est équipée d’un cordon d’alimentation
électrique de liaison à la terre à trois broches.
Pour minimiser les risques de choc électrique, on
doit brancher le cordon sur une prise de courant de
configuration correspondante, à 3 alvéoles, reliée à la terre
et installée conformément aux codes et règlements locaux.
Si une prise de courant de configuration correspondante
n’est pas disponible, le client a la responsabilité et
l’obligation de faire installer par un électricien qualifié
une prise de courant correctement reliée à la terre.
La prise à 3 broches reliée à la terre doit se trouver dans
un placard situé au-dessus de la hotte, à une distance
maximale de 33
7
/
16
" (85 cm) à partir du point duquel le
cordon d’alimentation sort de la hotte.
AVERTISSEMENT
Risque de choc électrique
Brancher sur une prise à 3 alvéoles reliée à la terre.
Ne pas enlever la broche de liaison à la terre.
Ne pas utiliser un adaptateur.
Ne pas utiliser un câble de rallonge.
Le non-respect de ces instructions peut causer
un décès, un incendie ou un choc électrique.
33
⁷⁄₁₆" (85 cm)
INSTRUCTIONS DE MISE À LA TERRE
CONSERVEZ CES INSTRUCTIONS
Pour une hotte reliée à la terre et connectée par un
cordon :
Cette hotte doit être reliée à la terre. Au cas où un court-
circuit se produirait, la liaison à la terre réduit le risque de
choc électrique, en permettant au courant de s'échapper
directement vers la terre. La hotte est équipée d'un cordon
comportant un conducteur de liaison à la terre avec fiche de
liaison à la terre. La fiche doit être branchée dans une prise
correctement installée et reliée à la terre.
AVERTISSEMENT : Une mise à la terre incorrecte
peut entraîner un risque de choc électrique.
Consulter un électricien qualifié si les instructions de mise à
la terre ne sont pas complètement comprises, ou si vous
avez des doutes quant à la qualité de la liaison à la terre de
la hotte.
Ne pas utiliser de câble de rallonge. Si le cordon
d'alimentation électrique est trop court, faire installer une
prise près de la hotte par un électricien qualifié.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Whirlpool UXT5530AAS Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation

dans d''autres langues