Warnings and Important Information _____________________________________________3
Professional Bottom-Freezer
Dimensions ______________________________________________________________ 6
Specifi cations _____________________________________________________________ 7
Cutout Dimensions _________________________________________________________8
Anti-Tip Dimensions (36”) __________________________________________________ 9
Cabinet Information (Professional) _____________________________________________ 10
Cabinet Information (Professional with fl ush mount trim) __________________________ 11
Custom Side Panel Dimensions (Professional) ___________________________________ 12
Custom Side Panel Dimensions (Professional with fl ush mount trim) ________________ 13
General Information __________________________________________________________ 14
Unpacking & Moving _________________________________________________________ 16
Flush Mount Side Trim Installation _____________________________________________ 17
Installation __________________________________________________________________ 17
Hinge Adjustment ________________________________________________________ 18
Kickplate Installation ______________________________________________________ 21
Door Stop Adjustment ____________________________________________________ 21
System Specifi cations and Data ____________________________________________ 22
Final Installation__________________________________________________________ 23
Performance Checklist ________________________________________________________ 24
Control Panels _______________________________________________________________ 25
Service & Registration ________________________________________________________ 26
33
IMPORTANT – Please Read and Follow!
Make sure that incoming voltage is the
same as unit rating. An electric rating
plate specifying voltage, frequency,
wattage, amperage, and phase is attached
to the product.
To reduce the risk of fi re, electrical shock,
or injury to persons, installation work and
electrical wiring must be done by a
qualifi ed technician in accordance with all
applicable codes and standards, including
re-rated construction.
The installer should leave these
instructions with the consumer who should
retain them for local inspector’s use and
for future reference.
DANGER
WARNING
You will be killed or seriously injured if
you don't follow instructions.
You can be killed or seriously injured if
you don't follow instructions.
All safety messages will identify the
hazard, tell you how to reduce the chance
of injury, and tell you what can happen if
the instructions are not followed.
Your safety and the safety of others is
very important.
We have provided many important safety
messages in this manual and on your
appliance. ALWAYS read and obey all
safety messages.
This is the safety alert symbol. This
symbol alerts you to hazards that
can kill or hurt you and others.
All safety messages will be preceded
by the safety alert symbol and the word
“DANGER” or “WARNING.” These
words mean:
4
IMPORTANT – Please Read and Follow!
A GFI shall be used if required by NFPA-70 (National Electric Code), federal/state/local
laws, or local ordinances.
• The required use of a GFI is normally related to the location of a receptacle with respect to
any signifi cant sources of water or moisture.
• AGA Marvel will NOT warranty any problems resulting from GFI outlets which are not
installed properly or do not meet the requirements below.
If the use of a GFI is required, it should be:
• Of the receptacle type (breaker type or portable type NOT recommended)
• Used with permanent wiring only (temporary or portable wiring NOT recommended)
• On a dedicated circuit (no other receptacles, switches or loads in the circuit)
• Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT
recommended)
• Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard)
• In good condition and free from any loose-fi tting gaskets (if applicable in outdoor situations)
• Protected from moisture (water, steam, high humidity) as much as reasonably possible
5
WARNING
TIP OVER HAZARD
Appliance is top heavy
and tips easily when not
completely installed. Keep
doors closed until appliance
is completely installed and secured per
installation instructions.
Use two or more people to move and
install appliance. Failure to do so can
result in death or serious injury.
WARNING
ELECTRICAL SHOCK
HAZARD
Disconnect power or turn
power disconnect switch to
OFF position before removing top grille.
Failure to do so can result in death or
electrical shock.
IMPORTANT – Please Read and Follow!
Most of the unit’s weight is at the top. Extra care is needed when moving the unit to prevent
tipping. Use cardboard shipping material or plywood under unit until it is installed in the
operating position to protect oor surface.
It is your responsibility to:
comply with installation specifi cations and dimensions.
properly install unit.
remove any moldings or decorative panels that prevent the unit from being serviced.
make sure that you have these materials (not provided with your unit), which are necessary
for proper installation:
• 1/4” (6 mm) copper tubing with shutoff valve
• 6– #8 x 3” (7.6 cm) wood screws (longer screws may be required)
• 1– Saddle valve (do not use self-piercing feature of the valve)
assure that fl oor will support unit, door panels and contents (approximately
1200 pounds [540 kg]).
provide a properly grounded electrical outlet.
assure that location will permit appliance doors to open 90º minimum.
6
Dimensions (Bottom-Freezer)
36” Bottom-Freezer
24”
(61.0 cm)
35”
(88.9 cm)
52”
(132.1 cm
)
23–1/16”
(58.5 cm
)
3–19/32”
(9.1 cm)
36”
36”
(91.5 cm)
(91.5 cm)
36”
(91.5 cm)
9–5/32”
(23.3 cm)
82–3/4”
(210.2 cm)
min.
to
84–1/16”
(213.5 cm)
max.
2
0–3/4”
(52.7 cm)
22–3/16”
(56.4 cm)
1–1/2”
(3.8 cm)
26”
(66.0 cm)
24”
(61.0 cm)
35”
(88.9 cm)
52”
(132.1 cm
)
23–1/16”
(58.5 cm
)
3–19/32”
(9.1 cm)
36”
36”
(91.5 cm)
(91.5 cm)
36”
(91.5 cm)
9–5/32”
(23.3 cm)
82–3/4”
(210.2 cm)
min.
to
84–1/16”
(213.5 cm)
max.
2
0–3/4”
(52.7 cm)
23–3/8”
(59.4 cm)
1–1/2”
(3.8 cm)
26”
(66.0 cm)
Note: Flush Mount Trim (PBIRFTKSS) purchased separately.
36” Bottom-Freezer with
Flush Mount Trim
7
Specifi cations (Bottom-Freezer)
36” Bottom Freezer
Description MP36BF2
Overall width 36” (91.5 cm)
Overall height (from bottom) 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max.
Overall depth from rear To front edge of side trim: 22-3/16” (56.4 cm)
To front of top grille: 24” (61.0 cm)
To front of handle endcap: 26” (66.0 cm)
Cutout width 35-5/8” (90.5 cm) min. to 35-3/4” (90.8 cm) max.
Cutout height
82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max.
Cutout depth 24” (61.0 cm) min.
Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.9 amps
Inlet water requirements 1/4” copper tubing inlet waterline; minimum 20 psi;
maximum 120 psi
Overall interior dimensions
Refrigerator
Freezer
Total capacity
15.3 cu. ft. (434 liters)
5.1 cu. ft. (145 liters)
20.4 cu. ft. (579 liters)
Approximate shipping weight 565 lbs. (254.3 kg)
36” Bottom Freezer with Flush Mount Trim
Description MP36BF2 w/Flush Mount
Overall width 36” (91.5 cm)
Overall height (from bottom) 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max.
Overall depth from rear To front edge of side trim: 23-3/8” (59.4 cm)
To front of top grille: 24” (61.0 cm)
To front of handle endcap: 26” (66.0 cm)
Cutout width 36” (91.5 cm)
Cutout height
82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max.
Cutout depth 24” (61.0 cm) min.
Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage 9.9 amps
Inlet water requirements 1/4” copper tubing inlet waterline; minimum 20 psi;
maximum 120 psi
Overall interior dimensions
Refrigerator
Freezer
Total capacity
15.3 cu. ft. (434 liters)
5.1 cu. ft. (145 liters)
20.4 cu. ft. (579 liters)
Approximate shipping weight 565 lbs. (254.3 kg)
8
Cutout Dimensions (Bottom-Freezer)
9”
(22.9 cm)
73-3/8”
(186.4 cm)
82–7/8”
(210.5 cm) min.
anti-tip board &
opening height
84–1/16”
(213.5 cm) max.
anti-tip board &
opening height
35–5/8”
(90.5 cm) min.
to
35–3/4”
(90.8 cm) max.
36”
(91.5 cm)
PFlush Mount only
24”
(61.0 cm)
Electric Outlet Location
Water Line Entry Area
6–3/4”
(17.1 cm)
7–5/8”
(19.4 cm)
3”
(7.6 cm)
5/8”
(1.6 cm)
5/8”
(1.6 cm)
10–1/2”
(26.7 cm)
5/8”
(1.6 cm)
10–3/4”
(27.3 cm)
1”
(2.5 cm)
3–5/8”
(9.2 cm)
Optional floor
water line entry
35–5/8”
(90.5 cm)
36”
(91.5 cm)
Flush Mount only
See Anti-Tip board installation
6”
(15.2 cm)
9”
(22.9 cm)
36” Bottom-Freezer
9
Anti-Tip Dimensions (Bottom-Freezer)
36” Bottom-Freezer
Two 2”x 4” Mounting Boards
3” (7.6 cm) x 3-1/2” (8.9 cm)
NOTE: If unit is installed deeper than
24” (61.0 cm), then shim behind the mounting
boards by the difference.
NOTE: If unit is installed deeper than
24” (61.0 cm), then shim behind the mounting
boar
ds by the difference.
One 2”x 4” Mounting Boar
d
3” (7.6 cm) x 3-1/2” (8.9 cm)
Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.
NOTE: Top of unit must be placed firmly under anti-tip board.
Anti-Tip Location
Flush Mount Anti-Tip Location
79–3/8”
(201.6 cm) min.
to bottom of
anti-tip board
80–1/2”
(204.6 cm) max.
to bottom of
anti-tip board
29–1/2”
(74.9 cm)
3–1/2”
(8.9 cm)
3”
(7.6 cm)
29–1/2”
(74.9 cm)
3–1/2”
(8.9 cm)
1.5”
(3.8 cm)
10
Cabinet Information (Professional)
Door
Wall
1–13/16”
(4.6 cm)
Space if 24”
standard
cabinet
depth is
used
3/4”
(1.9 cm)
Full End
Panel
24”
(61.0 cm)
Standard
Cabinet
Depth
1–3/4”
(4.4 cm) Offset
5/16”
(0.8 cm)
Professional models fi t “semi-fl ush” in standard 24” (61.0 cm) deep cabinet openings. The door
face protrudes 1-3/4” (4.4 cm) from the cabinet face. The handle protrudes an additional
2-1/2” (6.4 cm) into the room.
Top View
1–13/16”
(4.6 cm)
Space if 24”
standard
cabinet
depth is
used
Door
24”
(61.0 cm)
Standard
Cabinet
Depth
Wall
3/4”
(1.9 cm)
Full End
Panel
1–3/4”
(4.4 cm) Offset
Countertop
Overhang
11
Cabinet Information (Professional with Flush Mount Trim)
Top View
Top View
Door
24”
(61.0 cm)
Standard
Cabinet
Depth
25”
(63.5 cm)
Countertop
Depth
Wall
3/4”
(1.9 cm)
Full End
Panel
Door
Wall
1”
(2.5 cm)
space if
25” (63.5 cm)
cabinet depth
is used
3/4”
(1.9 cm)
Full End
Panel
25”
(63.5 cm)
Flush
1”
(2.5 cm)
space if
25” (63.5 cm)
cabinet depth
is used
Flush
Professional models with fl ush mount trim fi t fl ush in standard 24” (61.0 cm) deep cabinet
openings with no protrusion into the room except the handle protrudes 2-1/2” (6.4 cm) into the
room.
12
Custom Side Panel Dimensions
(Professional)
3/4”
(1.9 cm)
End panel
5/32”
(0.4 cm)
3/16”
(0.5 cm)
Back filler
panel
22-7/16”
(57.0 cm)
22-7/16”
(57.0 cm)
22-1/4”
(61.0 cm)
6”
(15.2 cm)
Optional kickplate
Notch, dimensions
determined by cabinets
82-7/8”
(210.5 cm) min.
to
84-1/16”
(213.5 cm) max.*
82-7/8”
(210.5 cm) min.
to
84-1/16”
(213.5 cm) max.*
6”
(15.2 cm)
22-1/4”
(61.0 cm)
* Depending on how high leveling feet are raised, and cabinet enclosure height.
13
Custom Side Panel Dimensions
( Professional with Flush Mount Trim)
* Depending on how high leveling feet are raised, and cabinet enclosure height.
3/4”
(1.9 cm)
End panel
1”
(2.5 cm)
1/4”
(0.6 cm)
Z-Bracket
21-3/4”
(55.2 cm)
21-3/4”
(55.2 cm)
24”
(61.0 cm)
Optional kickplate
Notch, dimensions
determined by cabinets
24”
(61.0 cm)
82-7/8”
(210.5 cm) min.
to
84-1/16”
(213.5 cm) max.*
82-7/8”
(210.5 cm) min.
to
84-1/16”
(213.5 cm) max.*
14
General Information
Area Requirements
Verify the following:
Unit can fi t into residence and can be
moved around corners and through
doorways.
Floors can support unit’s weight plus
food weight (approximately 1200 pounds
[540 kg] per unit).
Floors underneath refrigerator are level
with surrounding fi nished fl oor.
Rear wall is solid and is able to support
two horizontally mounted 2 x 4s (included)
bolted to two wall studs. The 2 x 4 board
bolt heads must be fl ush with 2 x 4 to
prevent obstruction.
Remove anything attached to rear or side
walls that can obstruct unit installation.
Cutout dimensions are accurate.
Electrical outlet is in correct location.
Water line is in correct location.
DO NOT install a refrigeration unit near
a heat source, nor in a location where the
surrounding temperature will fall below
60º F (16º C).
Electrical Requirements
It is the customer’s responsibility to:
Contact a qualifi ed electrical installer.
Assure that the electrical installation is
adequate and in conformance with
the National Electrical Code, ANSI/
NFPA 70-latest edition or Canadian
Electrical Code C22.1-1998 and C22.2
No. 0-M91 (or latest edition), and all local
codes and ordinances.
A 115 volt, 60-Hz, 15 amp, fused, electrical
supply is required. It is required that a
separate circuit serving only this appliance
be provided. This appliance is equipped
with a power supply cord having a 3-prong
grounding plug. To minimize possible
shock hazard, the cord must be plugged
into a mating 3-prong, grounding-type wall
receptacle. DO NOT use an extension cord.
If codes permit a separate grounding wire
to be used, it is recommended that a
qualifi ed electrician determine that the
grounding path is adequate.
DO NOT ground to a gas line. Check with a
qualifi ed electrician if you are not sure if the
appliance is properly grounded. DO NOT
have a fuse in the neutral or grounding
circuit.
Anti-Tip Requirements
The anti-tip boards should be fastened
into position prior to moving the unit into
the opening.
Note: Additional mounting boards may
be required if the unit does not touch
the back wall of the enclosure. To prevent
unit from tipping forward, it must be secured
in place with a solid soffi t or wood block.
15
General Information
Water Supply Requirements
Use only 1/4” (6 mm) copper tubing for
water line. DO NOT install copper tubing
in area where temperatures drop below
35º F (1.7º C). Before attaching copper
tubing to the unit, fl ush at least 2 quarts
(1.9 L) of water through the copper tubing
and into a bucket to remove any particles
in the water line.
AGA Marvel is not responsible
for property damage due to improper
installation or water connection.
Connect 1/4” (6 mm) fl exible copper
tubing to household plumbing in
compliance with local codes and
ordinances.
Length of copper tubing must reach from
water supply connection to the unit
connection with an additional length to
facilitate moving the unit out of enclosure
for cleaning or service. Tubing should be
soft instead of rigid and ends should be
free of burrs.
Copper tubing route must be above 35º F
(1.7º C) to prevent water line from freezing.
DO NOT use plastic water lines from
the household plumbing to the water
inlet valve connection on the
refrigeration unit.
DO NOT use the self-piercing feature of
a saddle valve. The hole made by the
piercing lance is too small for the water
ow rate required by the ice maker.
If saddle valve is not used, place a
separate shut-off valve in an easily
accessible location between water supply
and the unit. DO NOT install shut-off valve
behind the unit.
The installation of units with a reverse
osmosis system is acceptable as
long as the water pressure remains
within the allowable PSI as stated
below. It is important to note that with
many reverse osmosis systems, the
pressure starts off high, but then it
decreases as the water level of the reverse
osmosis storage area drops. This must
be considered when checking the water
pressure coming into the unit.
Connect a vertical or horizontal 1/2”
(1.3 cm) to 1-1/4” (3.2 cm) COLD water
line near water area.
Run water line through the fl oor, back,
or side wall. Tubing should lay fl at on fl oor
underneath the unit. Clamp tubing to wall
or oor.
Water pressure must be greater than
20 psi and less than 120 psi on non-
dispensers and greater than 35 psi and
less than 120 psi on dispensers.
WARNING
To avoid serious illness or death, DO NOT use
unit where water is microbiologically unsafe
or of unknown quality, without adequate
disinfection before or after the system.
Systems certi ed for cyst reduction may be
used on disinfected water that may contain
lterable cysts. The contaminants or other
substances removed or reduced by this water
treatment system are not necessarily
in your water.
CAUTION
Be sure to have a replacement cartridge
available when lter change is required.
• If water ltration system has been allowed to
freeze, replace lter cartridge.
If system has not been used in several
months, and water has an unpleasant
taste or odor, ush system by dispensing
2-3 glasses of water. If unpleasant taste or
odor persists, change lter cartridge.
16
General Information
Area Requirements
Most of the unit’s weight is at the top.
Extra care is needed when moving the unit
to prevent tipping.
DO NOT remove protective fi lm until unit
is in operating position.
All four leveling legs must contact the fl oor
to support and stabilize the full weight.
DO NOT drop unit.
Remove exterior shipping materials prior
to moving unit into home, except door
latching device.
Use two or more people to move and
install unit. Failure to follow this instruction
can result in back or other injury.
To avoid personal injury, wear gloves when
performing any installation procedure and
wear eye protection when cutting metal
straps.
Tip Over Hazard
Appliance is top heavy and tips easily when
not completely installed. Keep doors closed
until appliance is completely installed and
secured per installation instructions. Use
two or more people to move and install
appliance. Failure to do so can result in
death or serious injury.
Unpacking Unit
1. Remove top and bottom strap.
2. Remove top cap.
3. Cut carton rear approximately 1/4”
(0.6 cm) to 1” (2.5 cm) from right corner
with a utility knife extended 1/4” (0.6 cm).
4. Remove carton and exterior packaging.
Save cardboard shipping material to
protect oor surface when installing unit.
Remove anti-tip board and kickplate
from rear of unit.
Moving Unit
Remove shipping brackets from skid by removing four
bolts (two on each side) with a 1/2” (1.3 cm) deep-well
socket wench and a pair of pliers. Note: Tilting unit is
not required to remove shipping brackets.
Slip appliance dolly between unit and skid.
Remove unit from skid. Note: Use excess packaging
to protect decorative trim; also, verify that
leveling legs are up (0” adjustment).
17
Note: If the unit is to be installed fl ush with
the cabinets, the fl ush mount side trim must
be installed fi rst. If not, skip to “Installation”.
Step 1 - Locate the necessary parts: Two (2)
ush mount trim pieces and a hardware kit
with twenty-two (22) screws.
Step 2 - Remove the side trim on the
refrigerator and discard the trim and screws.
Step 3 - Align the top of the fl ush mount
side trim with the top of the unit's machine
compartment. Using the screws included in
the hardware kit, attach the side trim to the
unit, only using the holes visible through
the side trim. Note: DO NOT use the screw
holes in the machine compartment.
1
2
3
4
Place unit in front of cutout. Pull the center grille louver up at an angle and pull out.
Using an 8” (20.3 cm) magnetic nut driver, remove
the two 1/4” (0.6 cm) screws.
Remove grille assembly.
Installation
Flush Mount Side Trim Installation
(Sold Separately)
18
1
2
7
8a
Wall
2 x 4
Refrigerator
Front of unit
2
1 3
6
Replace unit top. Replace four side screws. Attach one 2 x 4 to wall stud (refer to dimensions page
for exact location).
Loosen the four hinge screws. Adjust door.
Retighten four hinge screws.
2
1
5
Remove four side screws and remove unit top.
8b
Wall
2 x 4
Refrigerator
9
If needed, depending on cabinet and depth,
attach second 2 x 4 to fi rst 2 x 4.
Plug in power cord to verify operation.
Note: Make sure power switch is in the “On” Position.
Hinge Adjustment
19
11
12
13
14
Pull supply tubing forward under unit.
Note: DO NOT use plastic water lines.
Flush water line by running two quarts of water
into a bucket. Turn water off.
Connect supply tube to water valve using
a 1/2” wrench. Note: DO NOT overtighten.
Turn on water supply and check for leaks.
10b
Place unit within 3” (7.6 cm) of being fl ush with cabinets. Note: To
avoid cabinet damage, place cardboard between cabinets and unit.
When moving unit, DO NOT crimp, kink or crush water supply line.
Carefully move unit until semi fl ush with cabinet
(depending on unit).
3”
3”
3”
10a
Hinge Adjustment (cont.)
20
17
Reinstall cabinet trim and screws.
15
Wall
2 x 4
Refrigerator
Screw
16
Lift unit off rollers to desired height and level unit using
a 5/16” head wrench. NOTE: DO NOT use an electric
device. Overtightening can cause damage.
Reinstall handle side door trim
and door trim screws.
Hinge Adjustment (cont.)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84

Marvel MP36BF2LS Guide d'installation

Catégorie
Frigos
Taper
Guide d'installation