Modern Forms PD-68356 Intrasection Mode d'emploi

Taper
Mode d'emploi
Modern Forms
www.modernforms.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
HARDWARE

• Read all instructions before installing.
• System is intended for installation by a licensed electrician in accordance with the National Electrical Code (NEC) and local regulations.
When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
• Retain installation instructions for future maintenance reference.
: All parts must be used as indicated in these instructions. This product is designed for use only with the supplied parts and/or
accessories designated for use by Modern Forms. Substitution of parts or accessories not designated for use with this product by
Modern Forms could result in personal injury or property damage, and will void the warranty. Contact an authorized dealer or the
manufacturer if any parts are damaged or missing.
: Coastal conditions may cause mineral and residue build-up on the xture. We recommend that customers in
coastal areas clean all external surfaces of the xture once every two weeks with a wet cloth.
: Pour éviter tout choc électrique, assurez-vous que le disjoncteur soit mis hors tension avant de commencer.
• Lisez toutes les instructions avant l’installation.
• Le système doit être installé par un électricien licensié conformément au code national de l’électricité (NEC), et également aux
règlements locaux.
• Lors de la manipulation du luminaire, n’appuyez pas sur les LED. Tenez-le uniquement par la base.
: Toutes les pièces doivent être utilisées comme indiqué dans ces instructions. Ce produit est conçu pour être utilisé seulement
avec les pièces et/ou accessoires fournis pour être utilisés avec les produits Modern Forms. Remplacer des pièces ou accessoires non conçus
pour ce produit Modern Forms pourrait causer des dommages corporels ou matériels et pourrait également causer l’annulation de la garantie.
Veuillez contacter un revendeur autorisé ou le fabricant si des pièces manquent ou sont endommagées.
: Les conditions côtières peut causer une accumulation de minéraux et de résidue sur le luminaire. Nous recommendons
aux clients qui resident dans les zones côtières de nettoyer toutes les surfaces externes du luminaire une fois toutes les deux semaines avec un
chion humide.
1
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement progr
JANUARY, 2017
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
am. Nov . 2019
Feb. 2022
INSTALLATION INSTRUCTIONS

PD-68356
Plastic Anchor
Qty: 2PCS+1 Extra
Mounting Screw
Qty: 1 Extra
Wood Screw
Qty: 2PCS+1Extra
BA
B
Wire Connector
Qty: 3pcs+1Extra
A
A
CDE
Union Joint
Qty: 2PCS
2
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement progr
JANUARY, 2017
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
am. Nov . 2019
Feb. 2022
INSTALLATION INSTRUCTIONS

PD-68356
Fig.1
Mounting Plate Dimensions
Fig.3
PREPARATION
A
A
A
B
A
C
A
D
A
E
Turn to down
9. Secure the xture to the mounting plate use the mounting screw (B).
10. For slope ceiling applications, rotate swivel at the top of the stem to ensure luminaire is aiming down (Fig.3).
CONNECTING THE WIRES (Fig. 2)
MOUNTING THE FIXTURE (Fig. 1)
3. Remove the mounting screw (B) from the xture, take down the mounting plate.
4. Drill holes in the wall aligned with the key holes located in the mounting plate, insert the plastic anchor(D).
5. Secure the mounting plate to the junction box using standard junction box screws that comes with the
junction box. fasten it to the wall using wood screw(C).
Note: (i) using any other non-original-manufacturer provided junction box screw may result in safety issue;
(ii) The side of the mounting back plate marked “GND” must face out.
6. Choose the number of the rods suitable for your application. Thread the xture wire through the rods, union joint, swivel and canopy.
Connect the xture, rods, union joint and swivel. Make sure all are tightened.
Note: When connecting the union joint (E), rst attach it to the rod, then attach it to the swivel.
7. Hook the safety cord to the mounting plate.
8. Connect the xture’s wires to junction box wires using wire connectors (A) as shown in Fig. 2, making sure that all wire connectors
are secured. If you outlet box has a green or bare copper ground wire, connect the xture’s ground wire to it. Otherwise, connect
the xture’s ground wire directly to the mounting plate using the GND screw provided. After wires are connected, tuck them carefully
inside the junction box.
1. Shut o the power at the circuit breaker and remove existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to
lose any small parts necessary for installation.
COMPLETING THE INSTALLATION (Fig. 1)
Fig. 2 Wiring
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Wire Connector
Fixture's wire
Mounting Screw
Wood Screw
Junction Box Screw
Canopy
Plastic Anchor
Swivel
Union Joint
6 x 12" Rods
2 x 6" Rods
Mounting Plate
Junction Box
Safety Cord
48
1w
1a
13”
11”
  • Page 1 1
  • Page 2 2

Modern Forms PD-68356 Intrasection Mode d'emploi

Taper
Mode d'emploi