5
Understanding the Status Light
Specifications
Electrical requirements: 2-bay charger x 12 V, 1.5 A
4-bay charger x 12 V, 2.4 A
8-bay charger x 12 V, 4.15 A
Operating temperature: 0°C to 35°C (32°F to 95°F)
Storage temperature: -30°C to 70°C (-22°F to 158°F)
Relative humidity: 0% to 95% non-condensing
Where to Find More Information
Go to the Intermec web site at www.intermec.com to find
manuals as PDF files. If you have any problems, please visit
our Product Support web site at intermec.custhelp.com or call
1-800-755-5505.
Color Description
Steady green Battery is fully charged.
Slow flashing
green
Battery is quick charging. Quick charging occurs for the first
hour that the battery is in the charger. After 1 hour, the
battery is charged to approximately 75% capacity.
Fast flashing
green
Battery is charging. A fully discharged battery charges to
100% capacity in approximately 3 hours.
Flashing red The battery temperature is too cold or too hot for the battery
to charge. Make sure that the temperature is from 0°C to
35°C (32°F to 95°F).
Steady red The battery is not charging, because the battery is faulty.
Replace the battery.
No light The charger is not operating. Make sure that the:
•battery is correctly inserted in the charger.
•power supply is properly connected to the charger and an
AC outlet.
•battery contacts are clean. To clean the contacts, rub
them with a pencil eraser and remove any eraser debris.