Safer together
Smart, discreet and fully automatic,
Vayyar Home protects 24/7.
Simply place it on the wall and if you fall,
it will get you help.
11
Power adapter Double-sided
adhesive strips
Vayyar Home device Instruction Manual
22
What’s In the Box
No ButtonsNo WearablesNo Cameras
IMPORTANT: Watch our video
installation guide to learn
how to setup your Vayyar
Home correctly.
Helpful infomation you will learn in the video:
How to choose the right location
How to mount Vayyar Home securely
How to test your device
Watch it now at
vayyarhome.com/go
4433
Warnings
1. Use and handle your Vayyar Home device carefully.
2. The Vayyar Home device can break if dropped.
3. Using a power adaptor other than the one provided can cause malfunction or
potentially damage the Device.
4. Opening or tampering with the Device voids the warranty.
5. Keep the device away from water. Water damage is not covered by the
warranty.
6. The device will not function during a power outage.
7. The device will not transmit an alert to an emergency contact if the WiFi in your
Home is not working.
8. You must follow the installation and use instructions or the device will
not work.
9. Do not mount on wallpaper because the device may fall o the wall or damage
the wallpaper.
10. Follow the instructions carefully before removing the device from the wall.
FCC Regulations
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this Device may not cause harmful interference,
and (2) this Device must accept any interference received, including interference
that may cause undesired operation. Any changes or modications not expressly
approved by the party responsible for compliance could void the user’s authority
to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital Device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment o and
on, the user is encouraged to try to correct the interference by one or more of
the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit dierent from that to which
the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
To maintain compliance with FCC’s RF Exposure guidelines, this equipment
should be installed and operated with a minimum distance of 20cm between
the radiator and your body. Use only the supplied antenna.
Changes or modications made to this equipment not expressly approved by
Vayyar Imaging Ltd. may void the FCC authorization to operate the equipment.
The device shall not be used on an airplane while airborne.
FCC ID: 2AHIS-VH02R01| Contains FCC ID: 2AHIS-V60G-HOME
For product available in the USA/Canada market, only channel 1~11 can be
operated. Selection of other channels is not possible.
Pour les produits disponibles aux États-Unis / Canada du marché, seul le canal 1
à 11 peuvent être exploités. Sélection d’autres canaux n’est pas possible.
The transmitter module may not be co-located with any other transmitter or
antenna.
Le module émetteur peut ne pas être coïmplanté avec un autre émetteur ou
antenne.
IC Regulations
Industry Canada ICES-003 Compliance : CAN ICES-3 (B)/NMB-3(B)
IC Caution: RSS-Gen Issue 4 December 2014”&”CNR-Gen 4e Décembre 2014:
Contact us at: homesupport@vayyar.com
Need Assistance with Installation?
Important tips when mounting Vayyar Home:
Mount Vayyar Home near an electrical outlet so that it can be plugged in.
Vayyar Home should have a direct line of sight of all parts of the room.
Make sure it is placed away from metallic objects.
When mounting on the wall:
Vayyar Home should be placed on the wall at a height of
5 feet / 1.5 meters from the floor to the center of the device.
Vayyar Home should be placed on a wall and not on or behind a window,
a TV or any piece of furniture.
When mounting on the ceiling:
Vayyar Home should be mounted in the center of the room.
The ceiling height be between 8’ 2’’- 9’ 10’’ / 2.5-3.0 m.
- English:
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s). Operation is subject to the following two conditions:
: (1) This device may not cause
interference, and (2) This device must accept any interference, including
interference
that may cause undesired operation of the device.
- French:
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux
appareils radio exempts de licence. L’exploitation est autorisée aux deux
conditions
suivantes:
(1) l’appareil ne doit pas produire de brouillage, et;
(2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d’encompromettre le fonctionnement.
IC: 21498-VH02R01 | Contains IC: 21498-V60GHOME.
IC Radiation Exposure Statement:
This equipment complies with IC RSS-102 radiation exposure limits set forth for
an uncontrolled environment. This equipment should be installed and operated
with minimum distance 20cm between the radiator & your body.
Cet équipement est conforme aux limites d’exposition aux rayonnements IC
établies pour un environnement non contrôlé. Cet équipement doit être instal
et utilisé avec un minimum de 20cm de distance entre la source de rayonnement
et votre corps.
CE:
Compliance with 2014/53/EU Radio Equipment Directive (RED)
In accordance with Article 10.8(a) and 10.8(b) of the RED, the following table
provides information on the frequency bands used and the maximum RF
transmit power of the product for sale in the EU:
This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
Hereby, Vayyar Imaging Ltd. declares that the radio equipment type Vayyar Home is in compliance with Directive 2014/53/EU
Frequency range (MHz) Max. Transmit Power (dBm/mW)
2400-2483.5 Up to 100mW
60 GHz Below 100mW