Cree UR Series LED Upgrade Kit Manuel utilisateur

Taper
Manuel utilisateur
1 of 5 LPN000171_J
UR Series
LED Upgrade Kit
Includes: 48" Linear Option
INSTALLATION INSTRUCTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
1. DANGER – RISK OF SHOCK – DISCONNECT POWER BEFORE INSTALLATION
DANGER – RISQUE DE CHOC – COUPER L’ALIMENTATION AVANT L’INSTALLATION
2. WARNING – Risk of re or electric shock. LED Upgrade Kit installation requires knowledge of luminaires electrical
systems. If not qualied, do not attempt installation. Product must be installed in accordance with NEC or your local
electrical code. If you are not familiar with these codes and requirements, contact a qualied electrician.
ATTENTION- Risque d’incendie ou de choc électrique. L’installation du kit upgrade LED exige la connaissance des systèmes
électriques pour luminaires. Si non qualié, ne tentez pas d’installation. Ce produit doit être installé conformément à NEC ou votre
code électrique local. Si vous n’êtes pas familier avec ces codes et ces exigences, veuillez contacter un électricien qualié.
3. WARNING – Risk of re or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for
installation of the LED upgrade kit. Check for enclosed wiring and components.
ATTENTION - Risque d’incendie ou de choc électrique. Câblage électriques peuvent être endommagés lors du perçage pour
l’installation du kit upgrade LED. Vérier les ls et composants.
4. WARNING – Risk of re or electric shock. Check the existing wiring for damage before installing upgrade kit. Do not
install if existing wires are damaged.
ATTENTION- Risque d’incendie ou de choc électrique. Vériez si le câblage existant n’est pas endommagé avant l’installation du
kit upgrade LED. Ne pas installer si des ls sont endommagés.
5. WARNING – To prevent wiring damage or abrasion, do not expose wires to the edge of sheet metal or any other sharp
objects.
ATTENTION - Pour éviter les dégâts de câblage par l’abrasion, ne pas mettre en contact les ls électriques avec des bords de
tôle ou d’autres objets pointus.
6. WARNING – Risk of re or electric shock. Install this kit only in the luminaires that have the construction features and
dimensions shown in the photographs and/or drawings.
ATTENTION - Risque d’incendie ou de choc électrique. Installez ce kit seulement dans les luminaires qui ont les caractéristiques
de construction et les dimensions dans les photographies ou les dessins de la page suivante.
7. The retrot assembly is accepted as a component of a luminaire where the suitability of the combination shall be
determined by ul or authorities having jurisdiction
Le montage rétracté est considéré comme le composant d’un système lumineux incandescent où l’adaptation à la structure doit
être déterminée par le csa ou les autorités en vigueur.
8. Only the holes indicated in the photographs or drawings may be made or altered as a result of the kit installation. Do not
leave any other holes open in a wiring enclosure or electrical component.
Seulement les trous indiqués dans les photographies ou les dessins peuvent être faits ou altérés pour l’installation du kit upgrade
LED. Ne laissez aucun trou ouvert dans le compartiment électrique.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
NOTES:
1. Upgrade Kit is for installation in a nominal 1x4 or 2x4 Listed dry or damp location fluorescent troffer, wrap or strip luminaire, with or without a
diffuser. The luminaire shall have the following minimum dimensions:
2-15/16” deep pan
3“ wide minimum wiring compartment
43” minimum length to accommodate lightbars
Only ONE kit is to be installed per luminaire
2. Consult your local authority regarding disposal or recycling of removed ballast and lamp.
LIST OF SUPPLIED COMPONENTS
Upgrade UR2 Single Kit contains the following parts:
UR2-48 drivers are used with UR48 Light Bars only.
UR2-24 drivers are used with UR24 Light Bars only.
(2) – LED lightbars
(1) – Driver (may be packaged separately)
(6) – Mounting Clips
(8) – #6-20 Self Drilling Screws
(1) - #8-32 Driver Mounting screw
(1) - Relamping label
Upgrade UR3 Single Kit contains the following parts:
UR3-48 drivers are used with UR48 Light Bars only.
UR3-24 drivers are used with UR24 Light Bars only.
(3) – LED lightbars
(1) – Driver ( may be packaged separately)
(9) – Mounting Clips
(12) – #6-20 Self Drilling Screws
(1) - #8-32 Driver Mounting screw
(1) - Relamping label
(1) - Extension Cable
2 of 5 LPN000171_J
TO INSTALL
NOTE: The instructions below reflect the steps necessary for
retrofit of a typical fluorescent troffer luminaire. These steps
are functionally identical for retrofit of a typical wrap or strip
luminaire.
STEP 1:
Locate latches on the lens frame and release them allowing
lens frame to swing open. Carefully let lens frame hang. See
Figure 1.
STEP 2:
Remove existing linear fluorescent tubes and properly
dispose of them. See Figure 2.
STEP 3:
To remove the wiring compartment, squeeze the sides in and
pull down and set aside. See Figure 3.
STEP 4:
Locate the existing ballast and remove the screw holding the
ballast to the housing. Properly dispose of the screw. See
Figure 3.
STEP 5:
To remove the ballast from housing, cut the leads from the
ballast to the socket housing on both ends of the luminaire
and cap socket leads. See Figure 4 and 5.
NOTE: When cutting leads, leave the smallest amount of wire
attached to luminaire.
1
3
2
4 5
3 of 5 LPN000171_J
6 7
8
STEP 6:
Cut the leads from the ballast to the input power ensuring
to leave as much length as possible for electrical
connections. Remove ballast from housing and
properly dispose of. See Figure 6.
STEP 7:
Push exposed socket leads back into socket housing on
each side of the luminaire or cap any exposed accessible
leads. See Figure 7.
STEP 8:
Prepare input power by stripping input power leads 1/4”.
See Figure 8.
STEP 9:
Bring new driver into housing using mounting holes from
old ballast and secure it using supplied #8-32 screw.
Ensure that the existing luminaire housing is properly
grounded to ensure proper driver grounding. See Figure 9.
NOTE: If housing has multiple locations for power supply,
new driver can be secured in any of these locations.
STEP 10:
Make electrical connection per “Electrical Connections”
section on page 5.
NOTE: Ensure that the driver is properly grounded to
luminaire using supplied screw from Step 9.
STEP 11:
Bring wiring compartment previously removed in Step 3 into
the housing. Carefully tuck all leads and wire connectors
into the wire compartment. Reattach wire compartment
by snapping into place over driver insuring no wires are
pinched. See Figure 10.
NOTE: Route the driver outgoing leads through the wiring
compartment allowing leads to be exposed through the end
of the wiring compartment. See Figure 10.
9
10
4 of 5 LPN000171_J
STEP 12:
Snap (3) supplied mounting clips onto each LED
lightbar. See Figure 11.
STEP 13:
Bring LED lightbar into housing and reposition
clips on LED lightbar as needed. For temporary
placement of LED lightbar the clips have
magnets located on the bottom of the clip.
Repeat this step for each LED lightbar supplied
in kit.
STEP 14:
Once all LED lightbars are in desired position
permanently secure them to housing by
inserting (2) supplied self tapping screws into
each end of the LED lightbar. See Figure 12.
NOTE: The middle bracket on the LED lightbar
DOES NOT need to be secured.
STEP 15:
Connect the power supply leads connector, that
is exposed at the end of the wiring compartment
with the LED lightbar connector. See Figure 13.
NOTE: For UR3 kits an extension cord needs
to be applied to the lightbar connector
farthest from the wiring compartment and the
power supply leads at the end of the wiring
compartment. See Figure 14.
NOTE: Place the relamp label, provided in the
kit, on the lighting compartment. Make sure that
the label is visible.
STEP 16:
Close the lens door and secure the latches.
11
13
12
14
Extension cord
Lightbar Connector
Power Supply Leads
5 of 5 LPN000171_J
www.cree.com/lighting
© 2015 Cree, Inc. All rights reserved. For informational purposes only. Content is subject to change.
See www.cree.com/lighting/products/warranty for warranty and specifications. Cree® and the Cree
logo are registered trademarks.
ELECTRICAL CONNECTIONS
Make the following Electrical Connections:
a. Connect the black fixture lead to the voltage supply Line position. SI Hot 1 and S2 Hot 2.
b. Connect the white fixture lead to the neutral supply position.
c. For Step Dimming refer to the table.
ELECTRICAL CONNECTIONS - 0-10V DIMMING (120-277VAC AND 347V MODELS)
STEP 1:
Connect power conduit and dimming conduit to access plates (and expanded J-Box if needed).
STEP 2:
Make the following Electrical Connections:
a. Connect the black fixture lead to the voltage supply Line position, Hot.
b. Connect the white fixture lead to the neutral supply position.
c. Connect the green or green/yellow ground lead to the supply ground lead.
d. If 0/1-10v Dimming is used, connect the violet lead to the supply positive dimming lead.
e. If 0/1-10v Dimming is used, connect the gray lead to the supply negative dimming lead.
Power
Output
Position
S1
On
On
Off
Off
S2
On
Off
On
Off
100%
50%
50%
0%
DRIVER ASSEMBLY
BLACK
BLACK
WHITE
NEUTRAL
S1
LINE S2
LINE
VIOLET
GREY
DRIVER ASSEMBLY
BLACK
WHITE
NEUTRAL
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Cree UR Series LED Upgrade Kit Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues