CAME CK0010, CK0014, CK0015 Guide d'installation

Taper
Guide d'installation
®
www.Came.com
24810650
001CK0010
001CK0014 FR-001CK0015 FR
English
EN
10
11
7
2
+
001DC011AC
001DC002AC
001DC011AC
001DC01EARY
001DC03EARY
001CS2PLCO
001CK0010-14FR-15FR 24810650 05-08-14_EN
2
General Notes
• Read the instructions carefully before beginning the installation and carry
out the actions as specied by the manufacturer.
The installation, programming, commissioning and maintenance of the
product must only be carried out by qualied technicians, properly trained
in compliance with the regulations in force, including health and safety
measures and the disposal of packaging.
The installer must ensure that the information for the user, where there is
any, is provided and delivered.
• Before carrying out any cleaning or maintenance operation, disconnect the
devices from the power supply.
The equipment must only be used for the purpose for which it was
expressly designed.
The manufacturer declines all liability for any damage as a result of impro-
per, incorrect or unreasonable use.
eventuali danni derivanti da usi impropri, erronei ed irragionevoli.
ÉLIMINATION - S’assurer que le matériel d’emballage nest pas abandonné
dans la nature et quil est éliminé conformément aux normes en vigueur
dans le pays d’utilisation du produit.
À la n du cycle de vie de l’appareil, faire en sorte qu’il ne soit pas abandonné
dans la nature.
L’appareil doit être éliminé conformément aux normes en vigueur et en
privilégiant le recyclage de ses pièces.
Le symbole et le sigle du matériau sont indiqués sur les pièces pour lesquelles
le recyclage est prévu.
Déclaration CE - Came Cancelli Automatici S.p.A. déclare que ce dispositif est
conforme à la directive 2014/30/UE. Original sur demande.
001DC01EARY-001DC03EARY
Wall-mounted installation
Remove the unit from the metallic support by sliding it after pressing the
plastic button A.
Attach the wall bracket to the round recessed box Ø 60mm Ba, the
rectangular box 503 B , B, the rectangular box 506E B, or the
UNICO recessed box (001DC004AC) using the provided screws and observing
the TOP indication. To ensure greater stability to the mounting surface,
secure box with screws and anchors provided.
The recessed box must be tted at a suitable height in relation to the user.
Avoid excessive tightening of the screws. Once the connections have been
made, hook the video terminal to the metal support CD. To release the
unit from the metal support, press the plastic hook and lift the terminal E.
1
2
a  
A
B
001CK0010-14FR-15FR 24810650 05-08-14_EN
3
Technical features
Type
001DC01EARY-001DC03EARY
Power supply from BUS [V DC]
15÷20
Consumption max [mA] 175
Consumption in stand by [mA] 1
Single LED consumption [mA]
1
Storage temperature [°C] -25 ÷ +70
Operating temperature [°C] +5 ÷ +40
IP Rating [IP]
30
Video signal system PAL/NTSC
Display LCD TFT 3,5’
Features F
Terminal board a
Doorbell
+
B BUS line input
Resistive load termination
CL.RES
XDV/304
CL.RES CL.RES
1 2 3
MASTER/SLAVE selection
M/S MASTER SLAVEM/S
Fam. Rossi
In case of simultaneous call, the audio/video communication will be
activated on the MASTER extension only.
D
C
E
F
a
– + B
CL.RES
M/S
001CK0010-14FR-15FR 24810650 05-08-14_EN
4
Melody setting
For call programming, see the entry panel documentation.
3sec
... beep!
3sec
... beep!
3sec
... beep!
3sec
... beep!
3sec
... beep!
3sec
... beep!
3sec
... beep!
a
Accessing programming. Press and hold the key for 3 seconds. A brief acoustic signal and
the blinking LED will conrm that programming has been accessed a.
Programming the melody associated to the call from the entry panel (1 acoustic signal).
To hear the melodies in sequence, press the key . To select the melody and exit the
programming, press the key . To select the melody and continue with programming,
press the key .
Programming the melody associated with the doorbell (2 acoustic signals). For this
type of programming proceed as previously described for “Programming the melody
associated to the call from the entry panel”.
Programming the number of call rings (3 acoustic signals). Press the key the number
of times equal to the rings selected for the call (1 to 6 rings). 3 s after the key is pressed
the last time, the call selected for the selected number of rings will be will be reproduced. To
save the new settings, press the button ; otherwise, press the door lock release button
( ) to enter the entry panel call melody programming procedure again.
001CK0010-14FR-15FR 24810650 05-08-14_EN
5
A
43,5
45
7,5 57
70
106
A
B
64,5
70
145
43,5
45
7,5 57
70
106
A
B
64,5
70
145
M2M1
+
a
001DC002AC
Installation
The power supplier must ALWAYS be installed horizontally. The device can be
installed on a DIN rail (EN 50022) in an appropriate electric panel.
NOTE. Proper ventilation is required if the power supplier is installed in a
metal container.
Technical features
Type
001DC002AC
Power supply [V AC] 230
Max current demand [A AC] 0,2
Max energy dissipation [W] 10
Nominal power supply [V DC] 18
Nominal current demand [A DC] 1 for 1’
Nominal current demand [A DC] 0.5 for 3’
Storage temperature [°C] -25 ÷ +70
Operating temperature [°C]
0 ÷ +35
IP Rating [IP] 30
Features A
Terminal board a
~Mains
~
Terminal board
+Power supply 18 VDC (*)
(*) The appliance is electronically protected against overloads and short
circuits.
001CK0010-14FR-15FR 24810650 05-08-14_EN
6
001DC011AC
Device description A
The 001DC011AC AC/DC converter is device designed for the installation
of audio receivers and video receivers coupled with a compatible gate
automatism equipped with an accessory output.
With just 4 wires that connect the gate with the audio receiver/video receiver
kit, the device not only supplies the kit but it also allows you to operate the
gate. Command 2-7 is executed by a clean contact (relay).
Technical features
Type 001DC011AC
Minimum input voltage (V AC) 20
Maximum input voltage (V AC) 25
Output voltage (V DC) 18
Output current (A) 1
Maximum operating relative humidity without
condensation 95
Storage temperature (°C) -25 ÷ +70
Operating temperature (°C) -15 ÷ +50
Features of terminals 2 - 7
Control voltage: 12V - 12.5 mA
Maximum switching voltage: 50 V AC or 75 V DC
Maximum switching power: 60VA - 24W
Function of terminals
18V DC supply output
+
2Opening command output towards gate
7
10 Power supply input 20÷25V AC
11
Opening command input from entry panel
48,5 mm
21 mm
60 mm
85,5 mm
69,5 mm
A
10
11
7
2
+
001DC011AC
a
001CK0010-14FR-15FR 24810650 05-08-14_EN
7
A B
D
135
99 30
3.5
6.5
243
207
135
99 30
3.5
6.5
243
207
001CS2PLCO
Wall Mounting
With the allen wrench unscrew the blocking screws and remove the plate
A. Fix the given plugs and screw the entry panel B at the desired height
considering the position of the lens of the camera C.
Run the hose with the system conductors B.
Extract the plastic terminal cover and wire the connections D.
Once all the connections have been made, re-insert the terminal covers.
For the installation of the accessories refer to the chapter “Button module in-
stallation”. Perform the programming and adjustment operations of the entry
panel as described to the chapter “Programming. Install the front plate A.
Recessed Installation (optional)
Install the recessed box at the desired height considering the position of
the lens of the camera C, but in advance, run the hose with the system
conductors through one of the breaking points F a.
C
500 mm
1080 mm
77°
94°
800 mm
500 mm
163,5 mm
43,5 mm
500 mm
1080 mm
77°
94°
800 mm
500 mm
163,5 mm
43,5 mm
H= 165 cm
(RECOMMENDED
HEIGHT)
001CK0010-14FR-15FR 24810650 05-08-14_EN
8
G
I J
F
H
1
2
During installation of the recessed box it is possible to avoid any deforma-
tion by using the provided spacer F . With the allen wrench unscrew
the blocking screws and remove the entry panel plate A. Introduce the
cable connections in the special hole B and x the entry panel on the
frame as shown in gure G; extract the plastic terminal cover and wire
the connections D.
Once the connections have been made and re-insert the terminal covers.
For the installation of the accessories refer to the chapter “Button module
installation”.
Perform the programming and adjustment operations of the entry panel as
described to the chapter “Programming. Install the front plate A.
Button module installation
Insert the button module as highlighted H paying special attention to the
top to bottom orientation J.
Remove the glass and write the user names I, paying special attention to
the orientation of the glass J.
A
B
a
E
001CK0010-14FR-15FR 24810650 05-08-14_EN
9
Accessories K
001DC00EGMA11 single button a,
001DC00PLACO01 Wall roof ,
Recessed box 001DC00PLCO03 ,
Recessed frame 001DC00PLACO02 .
K
a
53x13x0,3 mm 53x33x0,3 mm
Personalized labels, dimensions
M1
BOUT
M2
SW3
PROG RESET
LED PROG
M1
BOUT
M2
SW3
PROG RESET
PROG
a
Technical features
Type 001CS2PLCO
Power supply [V AC] 16-18
Consumption [mA] 250
Consumption in stand by [mA] 100
Storage temperature [°C] -25 ÷ +70
Operating temperature [°C) -15 ÷ +50
IP Rating [IP] 54
Standard video
PAL/NTSC
Resolution [pixel] 680x512
Minimum lighting [LUX] 1
Features L
Terminal board a
BOUT Riser
+Power supply 16-18 VDC
Terminal board
Earth
Door lock release button (NA)
Solenoid lock
12 V 1 A max
PROG key and PROG LED
Programming key and LED (see 'Programming' paragraph).
The PROG LED can take on the following states:
O
On
Slow ashing
Quick ashing
Adjustments
loudspeaker audio
microphone audio
Solenoid lock 1-10 s. (default 1 s)
L
001CK0010-14FR-15FR 24810650 05-08-14_EN
10
Connection example M
M1
BOUT
M2
SW3
PROG
RESET
PROG
M2M1
+
VLS/300
B
B
NO
C
+
001DC002AC
001DC005AC
M
Programming
The kit is pre-congured to manage a single call originating from a single entry panel. One or more receivers answering the same call can be added, by
following the below “Call button programming” procedure.
Initial programming
M1
BOUT
SW3
PROG RESET
PROG
M2
SW3
PROG RESET
PROG
SW3
PROG RESET
PROG
>3’
<6’
M1
BOUT
SW3
PROG RESET
PROG
M2
a
beep
A
SW3
PROG RESET
PROG
Entering Programming Mode. Press the PROG a key for at least 3 seconds and then release it
(within 6 seconds), as soon as the LED PROG lights up and the key back lighting ashes as illustrated
in gure . Failure of the PROG LED to light up, indicates a malfunction. Check the connections and
re-access the programming mode.
Programming of the Key Type. Press the rst key of the entry panel in the position indicated /
A until the backlighting LED stops ashing and remains lit.
Programming the call keys. Lift the receiver (if present) of the extension that you want to programme
then press the door lock release and AUX2 buttons. On the entry panel, press the call
key to associate with the internal extension : an acoustic signal will conrm that the setting was
stored. Hang up the receiver again, if necessary and continue, repeating the same operations for
the other extensions.
001CK0010-14FR-15FR 24810650 05-08-14_EN
11
SW3
PROG RESET
PROG
beep
SW3
PROG RESET
PROG
SW3
PROG RESET
PROG
SW3
PROG RESET
PROG
<1’
<1’
Exiting programming. Briey press the PROG
key : the PROG LED o. NOTE. If no action is
performed, the procedure will automatically end
after 30 minutes.
Reprogramming procedure
Entering Programming Mode. Press the PROG a key for at least 3 seconds and then release it (within
6 seconds) as soon as the LED PROG light ashes and the key back lighting lights up as illustrated in
gure . Failure of the PROG LED to light up, indicates a malfunction. Check the connections and
re-access the programming mode.
M1
BOUT
SW3
PROG RESET
PROG
M2
M1
BOUT
SW3
PROG RESET
PROG
M2
SW3
PROG RESET
PROG
>3’
<6’
 
SW3
PROG RESET
PROG
>3’
<6’
a
Programming the call keys. Lift the receiver (if present) of the extension that you want to programme
then press the door lock release and AUX2 buttons. On the entry panel, press the call
key to be associated with the internal extension : an acoustic signal will conrm that the setting
was stored. Hang up the receiver again, if necessary and continue, repeating the same operations
for the other extensions.
Exiting programming. Briey press the PROG key : the PROG LED o. NOTE. If no action is performed, the procedure will automatically end after 30 minutes.
Programming key type. At the “Programming Call Buttons” stage, press the PROG key for at least 3 seconds and then release it (within 6 seconds), as
soon as the LED PROG lights up and the key back lighting ashes as illustrated in gure, entering “Programming Button Types/Combinations as part
of the procedure.
Press the rst key of the entry panel in the position indicated until the backlighting LED stops ashing and remains lit.
At the end, exit programming, briey press the PROG key : the PROG LED will turn o. If no action is performed, the procedure will end automatically
after 30 minutes.
001CK0010-14FR-15FR 24810650 05-08-14_EN
12
Connection examples
a
a
 
001CS2PLCO
+
BOUT
-
-
-
M1
+
M2
M2
A
001DC01EARY
CL.RESM/S
M1
B
+
001DC002AC
001CS2PLCO
+
BOUT
-
-
-
M2
+
M2
M1
001DC002AC
A
001DC01EARY
CL.RESM/S
M1
B
+
001DC01EARY
CL.RESM/S
M1
B
+
001DC01EARY
CL.RESM/S
M1
B
+
001DC002AC
2
2
2
2
2
2
2
2
001DC002AC
2
001DC002AC
2
2
2
001DC011AC
4
4
10
11
7
2
+
001DC011AC
CAME GATE
001DC002AC
2
2
2
2
2
2
2
2
001DC002AC
2
001DC002AC
2
2
2
001DC011AC
4
4
10
11
7
2
+
001DC011AC
CAME GATE
001DC002AC
2
2
2
2
2
2
2
2
001DC002AC
2
001DC002AC
2
2
2
001DC011AC
4
4
10
11
7
2
+
001DC011AC
CAME GATE
001DC002AC
2
2
2
2
2
2
2
2
001DC002AC
2
001DC002AC
2
2
2
001DC011AC
4
4
10
11
7
2
+
001DC011AC
CAME GATE
001CK0010-14FR-15FR 24810650 05-08-14_EN
13
001CS2PLCO
2
12
OUT
SW2
SW4
SW3
001DC006AC
34
IN
SW0
+
BOUT
-
M1
001DC002AC
A
+
M2
-
-
M2
001DC01EARY
CL.RESM/S
M1
B
+
2001DC01EARY
CL.RESM/S
M1
B
+
1
001DC01EARY
CL.RESM/S
M1
B
+
1
001DC01EARY
CL.RESM/S
M1
B
+
1
2
+
BOUT
-
M1
-
-
M2
+
-
-
11
10
7
2
2
7
10
11
001DC01EARY
CL.RESM/S
M1
B
+
001CS2PLC0001DC011AC
CAME GATE
10
11
7
2
+
001DC011AC
001CK0010-14FR-15FR 24810650 05-08-14_EN
14
N° Slave
Lb
La
Lc
N° Master
001CS2PLCO
001DC006AC
001DC002AC
001DC011AC
VCM/1D UTP CAT5
N° Master 3 2 1 1
N° Slave 0 3 7 3
Distances
VCM/1D VCM/2D UTP/CAT 5 2x1mm22x2,5mm2
La+Lb ≤100 m ≤100 m
Lc ≤25 m ≤60 m
La+Lb+Lc ≤100 m
Distances
001CK0010-14FR-15FR 24810650 05-08-14_EN
15
001CK0010-14FR-15FR 24810650 05-08-14_EN
16
CAME Cancelli Automatici S.p.a.
Via Martiri Della Libertà, 15
31030 Dosson Di Casier (Tv)
(+39) 0422 4940
(+39) 0422 4941
Assistenza Tecnica/Numero Verde 800 295830
www. came.com
EN • For any further information on company, products and assistance in your language:
001CK0010-14FR-15FR 24810650 05-08-14_EN
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

CAME CK0010, CK0014, CK0015 Guide d'installation

Taper
Guide d'installation

dans d''autres langues