Safety Information
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANTSave these instructions for local
inspector’s use. Observe all governing codes and ordi-
nances.
Note to Installer Be sure to leave these instructions
with the Consumer.
Note to Consumer Keep these instructions with
your Owner’s Manual for future reference.
If you received a damaged unit, you should immediately
contact your dealer or builder.
Skill Level – Installation of this unit requires basic
mechanical, carpentry and plumbing skills. Proper
installation is the responsibility of the installer. Product
failure due to improper installation is not covered under the
GE Appliance Warranty.
See the Owner’s Manual for warranty information.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety
messages will follow the safety alert symbol and the word “DANGER”, “WARNING”, or “CAUTION”. These words are defined as:
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
WARNING
DANGER
CAUTION
For Monogram local service in your area, call 1.800.444.1845.
For Monogram service in Canada, call 1.800.561.3344
For Monogram Parts and Accessories, call 1.800.626.2002.
www.monogram.com
WARNING
Electrical Shock Hazard.
Plug into a grounded 3-prong outlet.
Do not remove the ground prong.
Do not use an adapter.
Immediately replace electric cords that become frayed
or damaged.
Do not use an extension cord with this appliance.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Follow the instructions in the section Grounding the
Unit.
WARNING
Tip Over Hazard.
These appliances are top heavy, especially with any doors open, and must be secured to prevent tipping forward
which could result in death or serious injury. Read and follow the entire installation instructions for securing the
appliance with the anti-tip system.
WARNING
Explosion Hazard.
Keep flammable materials and vapors, such as gasoline, away from appliance. Failure to do so can result in fire,
explosion, or death.
WARNING
To reduce the risk associated with choking, do not allow children under 3 years of age to have
access to small parts during the installation of this product.
CAUTION
Lifting Hazard
This unit is very heavy. To reduce the risk of person injury during maneuvering and installing this appliance, 3
people are required for proper installation.
CONSIGNES DE SÉCURITÉ
Ce symbole représente une alerte de sécurité. Ce symbole vous avise de dangers possibles pouvant causer la mort, des
blessures ou autres. Tous les messages de sécurité seront précédés du symbole d’alerte de sécurité ainsi que des mots «
DANGER », « AVERTISSEMENT » ou « MISE EN GARDE ». Ces messages sont les suivants :
Signale une situation qui présente un danger imminent et qui, si elle n’est pas évitée, entraînera des bles
sures graves, voire la mort.
Signale une situation qui présente un danger imminent et qui, si elle n’est pas évitée, peut entraîner des
blessures graves, voire la mort. .
Signale une situation qui présente un danger imminent et qui, si elle n’est pas évitée, peut entraîner des
blessures mineures ou graves.
AVERTISSEMENT
DANGER
ATTENTION
3
AVERTISSEMENT
Risque de basculement
Ces réfrigérateurs présentent une partie supérieure lourde, en particulier avec une porte ouverte; ils doivent donc
être fixés pour prévenir le basculement vers l’avant et le risque concomitant de blessure grave ou fatale. Lisez et
suivez les instructions d’installation complètes pour l’installation du système anti-basculement.
AVERTISSEMENT
Risque d’explosion.
Conservez les matériaux et vapeurs inflammables tels que l’essence à l’écart de votre réfrigérateur. Le non-
respect de cette instruction peut entraîner un risque d’incendie, d’explosion ou de décès.
AVERTISSEMENT
Pour réduire le risque d’étouffement pendant l’installation de ce produit, ne pas laisser les
petites pièces à la portée des enfants âgés de moins de 3 ans.
ATTENTION
Risque associé à la manutention d’une charge lourde
Ce réfrigérateur est très lourd. Pour réduire le risque de blessure lors de la manutention de ce réfrigérateur, trois
(3) personnes sont nécessaires pour procéder à l’installation appropriée du modèle 36 pouces, quatre (4) pour
l’installation des modèles 42 ou 48 pouces.
AVERTISSEMENT
Risque de choc électrique.
Branchez l’appareil dans une prise triple avec terre.
Ne retirez pas la broche de terre.
N’utilisez pas d’adaptateur.
Le non-respect de ces instructions peut entraîner des ris-
ques d’incendies, des chocs électriques ou la mort.
Remplacer immédiatement tout cordon électrique effilo-
ché ou endommagé.
N’utilisez pas de rallonge avec cet appareil.
Le non-respect de ces instructions peut entraîner des ris-
ques d’incendies, des chocs électriques ou la mort.
Suivez les instructions de la section Mise à la terre du
réfrigérateur.
4
Contents
Safety 2, 3
Planning Guide
The Installation Space 5
Dimensions and Clearances 5-7
Customization Basics 8
3/4” Overlay Panel Dimensions - Flush 8
1/4” Framed Panel Dimensions - Standard 9
3/4” Overlay Panel Dimensions - Standard 9
Side Panels 10
ZUG2 Grille Panel Dimensions 10
130° Door Swing 11
90° Door Swing 12
Installation Instructions
Tools, Hardware, Materials 13
Grounding the Unit 13
Parts Identification 14
Step 1. Remove Packaging 15
Step 2. Install Water Line 15
Step 3. Install Side Panels 15
Step 4. Install Case Trim 16
Step 5. Anti-Tip Procedures 17-18
Step 6. Level Unit 19
Step 7. Secure Unit to Cabinetry 19
Step 8, Secure Unit to Wall 20
Step 9. Adjust Door Swing 21
Step 10. Remove Door Trim 21
Step 11. Layout Decorative Door Panels 22
Step 12. Attach Brackets to Panels 23
Step 13. Hang Decorative Door Panels 24
Step 14. Layout Decorative Grille Panel 25
Step 15. Install Grille Panel 25
Step 16. Adjust Decorative Panels 26
Step 17 Replace Trim 27
Step 18. Connect Water Supply 28
Step 19. Start Icemaker 28
Step 20. Install Toekick 28
Design Guide
5
36" Frame to
Frame Width
*84" From
Floor to
Top Frame
35"
Case Width
*83-1/2"
at
Rear
25-3/8" Framed Models
25-3/4" Stainless Steel Models
Case Depth
Depth Including Handles:
26-7/8" Framed Models
27-3/4" Stainless Steel Models
28-11/16" Professional Models
THE INSTALLATION SPACE
Water And Electrical Locations
Electrical and water supply must be located as shown.
The Cutout Depth Must Be 24” Minimum
The unit will project forward, slightly beyond adjacent
cabinetry, depending on your installation.
Cutout Depth Beneath a Soffit:
When installed beneathh a soffit, the soffit cannot
exceed the 24” installation depth shown. The top case
trim overlaps the bottom of the soffit.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply
is required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install
a properly grounded 3-prong electrical receptacle
recessed into the back wall. Electrical must be
located on rear wall as shown.
Note: GFI (ground fault interrupter) is not
recommended.
• Water line can enter the opening through the
floor or back wall. The water line should be 1/4” O.D.
copper tubing or GE QuickConnect
kit between the
cold water line and water connection location, long
enough to extend to the front of the unit. Installation
of an easily accessible shut-off valve in the water line
is required.
DIMENSIONS AND CLEARANCES
* Shipping height. The
product can be adjusted
to fit into a cutout that
is 84-1/2” max. height.
Note that the top case
trim at the front is 1/2”
higher and will overlap
upper cabinetry or sof-
fit. Use leveling legs and
wheels for a maximum 1”
height adjustment.
Product Clearances
These units are equipped with a 3-position door stop.
The factory set 115° door swing can be adjusted to 90°
if clearance to adjacent cabinets or walls is restricted.
Order WX14X99 door stop for precise settings between
90° and 130°.
130° Door Swing
90° Door Swing
Allow 25” minimum clearance for a full 130° door
swing. Allow 15” for pan removal.
For a 90° door swing, allow 4” minimum clearance to
a wall for framed and stainless steel models. Allow 5”
minimum clearance for professional models. If the 90°
doorstop position is used, pan access is maintained but
pan removal is restricted.
See illustrations pages 6 and 7 to determine door swing
interaction with adjacent cabinets or countertops.
*4 stainless and trimmed
models. 5
Pro models.
*For standard installation, the finished cutout width
must be 35-1/2”.
*For flush mount installation, the finished cutout width
must be 39”.
115° Door Swing
Design Guide
6
These units are equipped with a 3-position door stop.
The factory set 115° door swing can be adjusted to 90°
if clearance to adjacent cabinets or walls is restricted.
Order WX14X99 door stop for precise settings between
90° and 115°.
When Installed into a corner:
Allow 15” for a full 115° door swing and pan removal.
Allow 4” min. clearance when door swing is adjusted
to a 90° opening for pan access, but pan removal is
restricted.
CLEARANCES FOR FLUSH INSTALLATION ONLY
ZUG2, ZUGSS2 Unified Grille Panel Kit
• If you are installing two units, side by side,
the installation space must be 75-1/8” wide.
Note: Additional cutout width may be required when
side panels are used. Add side panel thickness
to the finished cutout to calculate rough-in width.
The water and electrical locations for each product
must be located as shown.
A separate 115V, 60Hz., 15 or 20 amp power supply
is recommended for each product.
75-1/8" Finished Width
2-5/16"
24-3/16"
9"
5" 5" 5" 5"
5-1/2"
9"
5-1/2"
Electrical
Electrical
Area
Cold Water
Supply
Wall View
Cold Water
Supply
24" Minimum
Cutout Depth
84-1/2" Max
Finished
Opening
3-1/2"
3-1/2" 3-1/2" 3-1/2" 3-1/2"
3-1/2" 3-1/2" 3-1/2"
3-1/2"3-1/2"
Clearances for Multiple Single Door Installations
In a side-by-side installation of a left and right door
swing product, a 1-1/2” clearance between the units is
required. Order ZUGSS2 Stainless Steel Unified Grille
Panel Kit or ZUG2 Custom Panel Unified Grille Panel Kit
for one continuous grille panel.
15"
Min. to
Wall
15"
Min. to
Wall
115° Door
Swing
1-1/2"
115° Door
Swing
Clearances for two products installed side-by-side
with the same (left or right) door swing
Allow 2” minimum clearance between the products
to prevent door swing interference. Order the WX14X99
adjustable door stop to reduce the factory set 115°
door swing. Allow 15” minimum to a wall to achieve
full drawer extension and pan removal.
NOTE: ZUG2 and ZUGSS2 Grille Panel Kit will NOT fit this
installation.
4"
15"
Clearances for two products installed side-by-side
with right and left side hinges together
Allow 5” minimum between the two products to prevent
one door from striking the other. Use the WX14X99
adjustable door stop to reduce the factory set 115°
door swing and to allow pan removal.
NOTE: ZUG2 and ZUGSS2 Grille Panel Kit will NOT fit this
installation.
5"
FLUSH INSTALLATION ONLY
Design Guide
7
These units are equipped with a 3-position door stop.
The factory set 115° door swing can be adjusted to 90°
or 130° if clearance to adjacent cabinets or walls is
restricted. Order WX14X99 door stop for precise settings
between 90° and 130°.
When Installed into a corner:
Allow 25” for a full 130° door swing. Allow 15” for pan
removal. Allow 4” min. clearance when door swing
is adjusted to a 90° opening for pan access, but pan
removal is restricted.
25"
Min. to
Wall
130°
130° Door
Swing
CLEARANCES FOR STANDARD INSTALLATION AND STAINLESS MODELS ONLY
ZUG2, ZUGSS2 Unified Grille Panel Kit
• If you are installing two units, side by side,
the installation space must be 71-1/2” wide.
Note: Additional cutout width may be required when
side panels are used. Add side panel thickness
to the finished cutout to calculate rough-in width.
The water and electrical locations for each product
must be located as shown.
A separate 115V, 60Hz., 15 or 20 amp power supply
is recommended for each product.
Clearances for Multiple Single Door Installations
In a side-by-side installation of a left and right door
swing product, a 1” clearance between the units is
required. Order ZUGSS2 Stainless Steel Unified Grille
Panel Kit or ZUG2 Custom Panel Unified Grille Panel Kit
for one continuous grille panel.
Clearances for two products installed side-by-side
with the same (left or right) door swing
Allow 2” minimum clearance between the products
to prevent door swing interference. Order the WX14X99
adjustable door stop to reduce the factory set 115°
door swing. Allow 15” minimum to a wall to achieve
full drawer extension and pan removal.
NOTE: ZUG2 and ZUGSS2 Grille Panel Kit will NOT fit this
installation.
2"
15"
Clearances for two products installed side-by-side
with right and left side hinges together
Allow 5” minimum between the two products to prevent
one door from striking the other. Use the WX14X99
adjustable door stop to reduce the factory set 115°
door swing and to allow pan removal.
NOTE: ZUG2 and ZUGSS2 Grille Panel Kit will NOT fit this
installation.
5"
INSTALLATION FOR STANDARD AND
STAINLESS MODELS ONLY
Design Guide
8
CUSTOMIZATION BASICS:
Framed Or Overlay Panels, Custom
Handles and Accessory Kits
Professional Style Stainless Steel Models
Stainless steel wrapped refrigerators have beveled
edges and professional-style handles. These models are
shipped ready for installation.
Stainless Steel Wrapped Models
Stainless Steel wrapped models have wrapped doors
and grille panel, beveled edges, and tubular stainless
steel handles that coordinate with other Monogram
appliances. These models are shipped ready for
installation.
Trimmed Models
Trimmed models are designed to be customized with
decorative panels. Field installed custom door and grille
panels are required.
Optional Accessory Kits
• ZKHSS2: Monogram Tubular Stainless Steel handles
designed to fit 3/4” overlay panels.
• ZKHPSS1: Pro Tubular Stainless Steel handle designed
to fit 3/4” overlay panels.
• ZUG2: For side-by-side installation of two trimmed
models. This kit provides for the installation of a unified
custom grille panel to span the width of two units
using a framed or overlay panel.
• ZUGSS2: For side-by-side installation of two stainless
steel wrapped models. This kit provides a unified
stainless steel grille panel to span the width of two
units.
• ZTK36SDRHH: Trim kit for standard installation using
custom panels. This kit is for use with a right hand door
swing.
• ZTK36SDLHH: Trim kit for standard installation using
custom panels. This kit is for use with a left hand door
swing.
3/4” OVERLAY PANEL DIMENSIONS
(Flush Installation Only)
For a more custom appearance, overlay panels may be
installed to give a flush appearance with surrounding
cabinets. The overlay panel must be 3/4” thick. Panel
attaches to included brackets to provide mounting to the
appliance door.
IMPORTANT NOTE: Maximum total weight for the assembled
panels:
Door panel – 67 lbs. Grille Panel – 18 lbs.
1/2”
1/2”
1-1/4”
1”
1-1/4”
1”
Top/Bottom Hinge
Clearance
Router 1/8” Deep
Grille Panel
Door
Panel
38"
9-5/8"
69-13/16
"
CUSTOM HANDLE DESIGN GUIDE
(Flush Installation Only)
For custom handle installation, counterbore holes in
rear of decorative panels may not exceed 1/4” depth
to ensure 1/2” material thickness remains for handle
support. NOTE: The counterbore must not exceed 1” in
diameter.
Minimum distance from
handle side edge to handle
center should be 2-1/2” as
shown.
1/4”
1/2”
3/4”
2-1/2”
Improper installation can lead to a finger pinch
point hazard between the side door trim and the
cabinets when operating the door, especially
with children. To minimize this risk you must
follow the installation instructions for cabinet
dimensions, trim assembly, and door stop angle.
Door Trim Pinch Point Hazard
WARNING
Design Guide
9
If you choose to install framed panels, they must be cut to
the dimensions shown. The panels will slide into the frame
on the door and grille.
If the custom panel is less than 1/4” thick and if it fits
loosely in the door frame, it can be backed up with a piece
of filler material or foam tape to improve the fit.
IMPORTANT NOTE: Maximum weight for door panel
is 67 pounds. Maximum total weight for assembled grille
panel is 11 pounds.
3/4” OVERLAY PANEL DIMENSIONS
(Standard Installation Only)
For a more custom appearance, overlay panels may
be installed on trimmed models. The overlay panel must
be secured to a 1/4” thick backer panel which slides
into the trim. A spacer panel 0.10” thick must be placed
between the overlay and backer panel.
IMPORTANT NOTE: Maximum total weight for assembled
door panel is 67 pounds. Maximum total weight for
assembled grille panel is 11 pounds.
Assemble the panels with glue and screws.
• Center the spacer panel on the backer panel, left to
right and top to bottom. Secure the panels with glue.
• Center the spacer and backer panel on the overlay
panel and secure with glue and screws. Screws must
be countersunk into the backer panel.
Framed Panel Dimensions
A (Width) B (Grille Height) C (Door Height)
1/4” Framed Panel 33-7/8” 8-7/8” 69-5/16”
Overlay Panel Dimensions
A (Width) B (Grille Height) C (Door Height)
1/4” Backer Panel 33-7/8” 8-7/8” 69-5/16”
0.10” Spacer Panel 32-1/2” 7-5/8” 67-15/16”
3/4” Overlay Panel 34-1/8” 9” 69-9/16”
NOTE: Left-to-right offset is not always equal
to top-to-bottom offset.
1/4"
Panel
Door
5/16"
Trim
Reveal
1/4” FRAMED PANEL DIMENSIONS
(Standard Installation Only)
10
SIDE PANELS
Side panels must be used whenever the sides of the unit
will be exposed. The 1/4” side panels will slip into the
side case trim. Secure the panels to the unit with stick-
on hook and loop fastener strips. Order the side panels
from the cabinet manufacturer.
Cut a notch in the top front corner as shown to allow
clearance for corner keys in the front side trim.
ZUG2 GRILLE PANEL DIMENSIONS
The ZUG2 unified grille panel kit provides for the
installation of a framed or overlay grille panel.
* Depending on
installation height.
Assemble the overlay panels in the same manner
as the door panel.
Framed Panel Dimensions
A (Width) B (Height)
1/4” Framed Panel 69-7/8” 8-7/8”
Overlay Panel Dimensions
A (Width) B (Height)
1/4” Backer Panel 69-7/8” 8-7/8”
0.10” Spacer Panel 68-1/2” 7-5/8”
3/4” Overlay Panel 70-1/8” 9”
IMPORTANT NOTE: The maximum weight for the
unified grill is 25 pounds.
Design Guide
*84"
2-9/16"
24"
*3" to 4"
3/16"
1-7/8"
Design Guide
11
Top View
130° DOOR SWING
(Standard Installation Only)
Scale 1:1
Frameless Cabinets: The case trim
overlaps cabinets at the top and sides.
Therefore, frameless cabinets may require filler
strips to prevent interference with cabinet door
swing. The opening must allow for filler strips.
Design Guide
12
1/4"
1/2"
3/4"
1"
1-1/4"
1/4"
1/2"
3/4"
1"
1-1/4"
1-1/2"
23-7/8"
From Rear of
Unit
Cabinet Front
3/4" Overlay
Panel
(Nominal Size)
Case Trim
Refrigerator
or Freezer
Door
Top View
90° DOOR SWING
(Standard
Installation Only)
Scale 1:1
Frameless Cabinets:
The case trim overlaps
cabinets at the top and sides.
Therefore, frameless cabinets
may require filler strips
to prevent interference
with cabinet door swing.
The opening must allow
for filler strips.
Installation Instructions
13
HARDWARE SUPPLIED
• Water filter bypass plug
• Anti-Tip brackets
• 3 lag screws
• 2 Hair Pin Cotters
• 4 washers
• 5 toggles with bolts
• Toekick
TOOLS AND MATERIALS REQUIRED
Tin snips to cut banding
#2 Phillips screwdriver
• Stepladder
Drill and 1/2”, 3/16” bits
• Bucket
1/4”, 1/2”, 5/16”, 7/16” socket
• Level
• Safety glasses
• Appliance hand truck
• Pliers
• Tubing cutter
• Stud finder
7/16” and 1-1/4” open-end wrench
1/4” copper water line tubing or GE SmartConnect
Refrigerator Tubing kits
Water shut-off valve (optional but recommended)
Custom panels for door and grille panel
Screws to secure unit to cabinetry
Stick-on hook and loop fastener strips for
1/4” side panels
Flush install panel bracket kit
• Case Trim
FLOORING
For proper installation, this product must be placed
on a level surface of hard material that is at the same
height as the rest of the flooring. This surface should be
strong enough to support a fully loaded refrigerator or
freezer, or approximately 1,200 lbs. per unit.
NOTE: Protect the finish of the flooring. Cut a large sec-
tion of the cardboard carton and place under the prod-
uct where you are working.
NOTE: Not recommended for installation on carpeted flooring.
GROUNDING THE UNIT
WARNING
Electrical Shock Hazard.
Failure to follow these instructions can result in death,
fire, or electrical shock.
The power cord of this appliance is equipped with a
3-prong (grounding) plug which mates with a standard
3-prong (grounding) wall receptacle to minimize the
possibility of electric shock hazard from this appliance.
Have the wall outlet and circuit checked by a qualified
electrician to make sure the outlet is properly grounded.
Where a standard 2-prong wall outlet is encountered, it
is your personal responsibility and obligation to have it
replaced with a properly grounded 3-prong wall outlet.
DO NOT, UNDER ANY
CIRCUMSTANCES, CUT OR REMOVE
THE THIRD (GROUND) PRONG
FROM THE POWER CORD.
DO NOT USE AN ADAPTER PLUG
TO CONNECT THE REFRIGERATOR
TO A 2-PRONG OUTLET.
DO NOT USE AN EXTENSION CORD WITH THIS
APPLIANCE.
LA TERRE DE L’UNITÉ
AVERTISSEMENT
Risque de choc électrique.
Le non-respect de ces instructions peut entraîner des
risques d’incendies, des chocs électriques ou la mort.
Le cordon d’alimentation de cet appareil est équipé
d’une fiche à trois broches (pour une mise à la terre)
qui s’adapte à la prise de courant standard à 3
broches (pour une mise à la terre) pour minimiser les
risques de chocs électriques par cet appareil.
Faites vérifier la prise murale et le circuit électrique par
un électricien qualifié pour s’assurer que le système est
correctement mis à la terre.
Dans le cas d’une prise biphasée, l’installateur a la
responsabilité et l’obligation de la remplacer par une
prise triphasée correctement mise à la terre.
NE COUPEZ PAS OU N’ENLEVEZ
PAS, SOUS AUCUN PRÉTEXTE,
LA TROISIÈME BROCHE DE
MISE À LA TERRE DU CORDON
D’ALIMENTATION.
N’UTILISEZ PAS D’ADAPTATEUR
POUR BRANCHER LE
RÉFRIGÉRATEUR À UNE PRISE BIPHASÉE.
N’UTILISEZ PAS DE RALLONGE AVEC CET APPAREIL.
PARTS IDENTIFICATION:
14
Installation Instruction
Trim, Handle Side
Visor
Trim, Handle Side
Cover
Trim, Freezer Hinge
Side
Trim, Case, RH Side
Trim, Case, LH Side
Panel Bracket, Top Right
Panel Bracket, Bottom Left
Panel Bracket, Bottom
Right
Panel Bracket, Top Left
Panel Bracket, Top
Panel Bracket, Bottom
Door Bracket (4);
Installed on door
TOP IF HINGES ARE ON THE LEFT
TOP IF HINGES ARE ON THE RIGHT
BOTTOM IF HINGES ARE ON THE RIGHT
BOTTOM IF HINGES ARE ON THE LEFT
Door Panel Template
Grille Template
Door Trim Top
Door Trim, Bottom
Installation Instructions
15
STEP 3 INSTALL SIDE PANELS
Skip this step when not using side panels
If you are using 1/4” side panels, they should be inserted
into the case trim.
STEP 1 REMOVE PACKAGING
WARNING
Tip Over Hazard.
Product is much heavier at the top than at the bottom
– be careful when moving. When using a hand truck,
handle from side only.
AVERTISSEMENT
Risque de basculement
Le produit est beaucoup plus lourd en haut qu’en bas. Il
faut être prudent lors des déplacements. Si un diable est
utilisé, il faut soulever le réfrigérateur sur le côté seule-
ment.
• Carefully cut banding at the top and bottom, remove
outer carton.
• Slide out back corner posts (2).
• Slide carton off top of cabinet.
NOTE: IT IS NOT NECESSARY TO LAY CABINET DOWN
IN ORDER TO REMOVE SKID!
NOTE: DO NOT ATTEMPT TO ROLL UNIT OFF SKID.
STEP 2 INSTALL WATER LINE
• A cold water supply is required for automaticicemaker
operation. The water pressure must be between 40 and
120 p.s.i.
• Route 1/4” OD copper or GE SmartConnect
plastic
tubing between house cold water line and the water
connection location.
• Tubing should be long enough to extend to the front of
the unit. Allow enough tubing to accommodate bend
leading into the water line connection.
NOTE: The only GE approved plastic tubing is supplied in
the GE SmartConnect
Refrigerator Tubing kits. Do not
use any other plastic water supply line because the line
is under pressure at all times. Other types of plastic may
crack or rupture with age and cause water damage to
your home.
GE SmartConnect
Refrigerator Tubing Kits are available
in the following lengths:
2’ (.6 m) WX08X10002
6’ (1.8 m) WX08X10006
15’ (4.6 m) WX08X10015
25’ (7.6 m) WX08X10025
• The unit is secured to the skid with 4 slotted tie-down
straps. Remove the four 5/16” bolts from the base
channels in the tie-downs.
Remove toekick, custom handle trim, and wall brack-
et. Set aside for final installation.
• Lift the unit off the skid with an appliance dolly.
Handle from the sides.
• Remove the four 7/16” bolts securing the tie-down
brackets to the skid.
NOTE: Commonwealth of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle valves
are illegal and use is not permitted in Massachusetts.
Consult with your licensed plumber.
Shut off the main water supply.
Turn on the nearest faucet long enough to clear the line
of water.
Install a shut-off valve between the icemaker water
valve and cold water pipe in a basement or cabinet.
The shut-off valve should be located where it will be
easily accessible.
Turn on the main water supply and flush debris. Run
about a quart of water through the tubing into a
bucket. Shut off water supply at the shut-off valve.
NOTE: Saddle type shut-off valves are included in many
water supply kits. Before purchasing, make sure a saddle
type valve complies with your local plumbing codes.
Fasten the panels to the unit with stick-on hook and
loop fastener strips before setting unit in place.
Standard/Stainless Installation Only
The kit supplied with the unit contains 2 lag bolts and 4
toggles with bolts. The wall bracket will be attached to
the wall in 4 places.
Measure the opening where the unit is to be installed.
Mark the center with a vertical line.
Measure up 81 1/2” from the floor. Mark this point on
the wall.
Using a level, draw a horizontal line on the wall at this
height.
Locate at least 2 studs on the back wall. Mark these
points on the horizontal line.
Place the bottom of the wall bracket with tabs on the
horizontal line. Align the center notch on the bracket
with the center line on the wall.
• The anti-tip wall bracket has a series of holes. Select 2
holes that match with the located studs. Make sure the
holes selected are on the center of the studs. Mark the
wall at these points.
Installation Instructions
16
WARNING
Tip Over Hazard.
The unit is top-heavy and must be secured to prevent the
possibility of tipping forward.
AVERTISSEMENT
Risque de basculement
L’appareil ménager est beaucoup plus lourd en haut et il
faut le maintenir en place pour éviter la possibilité de son
basculement vers l’avant.
Flush Installation Only
• Cut a 1/2” x 4” block, 35” long.
• Measure and mark under the soffit,
5-1/4” from the front edge of the
cabinet.
• Secure the wood block to under the
soffit. From the bottom of the block
to the finished floor should measure
84”. See the illustration.
STEP 5 INSTALL ANTI-TIP BRACKET
STEP 4 INSTALL CASE TRIM
Install case trim using supplied right hand and left hand
case trim pieces and case trim screws. Attach case trim
to each side of case as shown in illustration using case
trim screws in holes provided down each side of case.
STEP 5 INSTALL ANTI-TIP BRACKET
(cont.)
Gently pull back at the ends of the plastic straps to make
the channel rest flush behind the wall.
Hold the ends of the straps in one hand and slide the plas-
tic cap along the straps until the flange of the cap is flush
with the wall.
Place your thumb between the plastic straps and bend up
and down to snap the straps off at the wall.
Install Screws and Bolts:
Have someone hold the wall bracket centered in place
with each of the holes aligned with the correct opening in
the bracket and level with the horizontal line.
Insert the lag screws through the bracket and into the
stud. Tighten with a wrench.
Insert the bolts into the toggle by hand until snug.
Tighten with a wrench.
Anti-Tip Wall Bracket
Bolt
Wall Toggle
Drywall or
Steel Stud
• Mark an additional hole at each end of the bracket. If one
of the studs is closer to the end of the bracket, mark an
additional hole towards the center of the bracket.
• Drill 1/2” holes into the wall board at the locations marked
for the toggles to be mounted (not the stud markings).
• Drill 3/16” holes into wooden studs where marked. If steel
stud construction, drill 1/2” holes into the studs where
marked. You will use 2 toggles with the metal studs.
Install Wall Toggles:
The wall toggles and bolts can be ordered as Service Kit
#WR49X10193. Wall toggles are installed in the drywall
and metal studs for stability. Install the wall toggles as fol-
lows:
Drill 1/2” holes at the wall markings made in the holes at
the ends of the wall bracket.
Hold the metal channel flat against the plastic straps
and slide the channel through the hole.
Installation Instructions
17
Plastic Straps
Metal Channel
Wood Stud
Lag Screw
Anti-Tip Wall Bracket
Two Additional
Hole Locations at
Ends of Brackets
Center
Wall Bracket
Line On Wall
Wall Studs
Line on Wall
Center
Cap
STEP 5 INSTALL ANTI-TIP BRACKET
(Standard/Stainless Installation
only) (cont.)
Installation Instructions
18
STEP 5 INSTALL ANTI-TIP BRACKET
(Standard/Stainless
Installation only) (cont.)
Remove Grilles for Access to Anti-Tip Locking Hooks
Fresh Food Unit
Open the access door.
Remove the 4 screws from the grille.
Pull the bottom of the grille forward, down and out
to remove.
Freezer Unit
Open the access door.
Remove the 4 screws from the grille.
Pull the bottom of the grille forward, down and out
to remove.
Power Cord
Locate the power cord inside the left cavity. If it has not
been adjusted so the plug is easily accessible,
do so now.
Move Unit into Final Position
Move appliance toward its final installed location.
Align the tabs on the wall bracket with the openings
in the back of the unit.
The unit has “L” bolts in the upper left and right
corners inside of the access compartment. These
bolts will interlock with the wall bracket and secure
the unit using the washers and hair pin cotters
in the hardware kit once the unit has been leveled
and is in the final position.
19
Installation Instructions
STEP 6 LEVEL UNIT
All models have 4-point leveling. The front is supported
by leveling legs; the rear is supported by adjustable
wheels. Both are accessible from the front of the unit.
• To level the back of the unit, turn the 7/16” hex nut
located above the front wheels. Turn clockwise
to raise or counterclockwise to lower the unit.
• For front leveling, use a 1-1/4” open-end wrench.
• Adjust height of unit to match installation cutout
opening 84-1/2”. The unit should be level and plumb
with cabinetry.
NOTE (Flush Installation Only): Raise appliance until
the case top comes in contact with the 1/2” spacer
block mounted to the underside of the cabinet soffit.
Appliance should be level at fully raised position.
CAUTION
The rear leveling wheels and front leveling legs are
limited to a maximum height adjustment of 1”. If the
installation requires more than 84-1/2” height, the
installer should elevate the unit on a sheet of plywood
or runners. Cabinetry trim could also be added across
the top of the opening to shorten the opening. If you
attempt to raise the unit more than 1”, you will damage
the front leveling legs and the rear leveling wheels.
ATTENTION
Les roues de nivellement arrière et les pattes de
nivellement avant permettent un réglage maximal
de 25 mm (1 po). Si l’ouverture pour l’appareil
ménager a une hauteur supérieure à 2,15 m (84-1/2
po), l’installateur doit élever l’appareil ménager sur
une feuille de contre-plaqué ou des glissières. Il est
également possible d’ajouter des baguettes de finition
des placards sur le haut de l’ouverture afin de la
réduire. Lever l’appareil ménager de plus de 25 mm
(1 po) endommage les pattes de nivellement avant et
les roues de nivellement arrière.
STEP 7 SECURE APPLIANCE
TO CABINETRY
Flush Installation Only
Whenever possible, perform this step for anti-tip security,
or when anti-tip brackets cannot be used. The appliance
must be secured to prevent tipping.
• Raise the grille panel to access the machine compart-
ment.
• For flush inset installation only, drill a hole in the case
top and drive a screw through the top into the adjacent
1/2” block.
Installation Instructions
20
STEP 8 SECURE UNIT TO WALL
Standard and Stainless Installation Only
The “L” rods can be found in the upper left and right
corners of the unit in the access compartment. Look
through the access compartment to make sure the rods
line up with the anti-tip bracket.
There are 2 washers and a hair pin cotter per rod.
Remove the washers and hair pin cotter from the end of
the rod.
Rotate and move the “L” rod into the slot in the anti-tip
bracket tab. Once it is in the slot, rotate the “L” rod so
the hook portion is pointing down. The holes at the front
end of the rod should be in a vertical position. Do this to
both sides.
Pull out on the end of the rod to make sure it is secure in
the bracket.
Locate the hole on the rod that is closest to the unit. A
hair pin cotter will be put through this hole to secure the
rod. If this hole appears to be too far away for a snug fit
against the unit, add the washers one at a time until the
pin will fit tightly into the hole.
Align the straight section of the pin with the hole from
the underside of the rod. Push the pin up until it snaps
into position. Pliers may be used. NOTE: The hair pin
cotter must be vertical when this step is completed to
ensure the “L” rod is engaged in the bracket.
Check the rod for tightness by pulling forward. If the rod
moves, remove the hair pin cotter and place another
washer on the rod. Reinsert the pin.
Replace the grille panel.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Monogram ZIRP360NHRH Guide d'installation

Catégorie
Frigos
Taper
Guide d'installation
Ce manuel convient également à

dans d''autres langues