Lumination LRXD Series Disk Downlight Retrofit Guide d'installation

Taper
Guide d'installation
Installation Guide / Manuel d’installation
IND584 | A-1028965
Lumination® LRXD
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 1 of 3
(Rev 06/08/23)
IND584-Lumination-LRXD-Disk-Light-Retrofit-Install-Guide_R01
BEFORE YOU BEGIN/
AVANT DE COMMENCER
Read these instructions completely and carefully.
Lisez attentivement toutes ces instructions.
Lumination® LED Luminaire
(LRXD Series)
WARNING / AVERTISSEMENT
RISK OF ELECTRICAL SHOCK. Turn power off before inspection, installation or removal. Install this kit only in the luminaires that has the construction
features and dimensions shown in the photographs and/or drawings. Installation of this retrot assembly requires a person familiar with the construction
and operation of the luminaire’s electrical system and the hazard involved. If not qualied, do not attempt installation. Contact a qualied electrician.
To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. Do not make or alter any open holes in an
enclosure of wiring or electrical components during kit installation.
RISQUES D’INCENDIE OU DE DÉCHARGES ÉLECTRIQUES. Coupez l’alimentation avant d’inspecter, installer ou déplacer le luminaire. Risques
d’incendie ou choc L’installation de trousses de mise à niveau au DEL nécessite des connaissances des systèmes électriques d’éclairage. Risque d’incendie
ou d’électrocution. N’ installer cette trousse que sur des luminaires qui ont les caractéristiques de construction et les dimensions telles que montrées sur
les photographies et dessins présentés. Pour prévenir les dommages ou l’abrasion de ls électriques, ne pas exposer les ls aux arêtes de pièce de tôlerie
ou n’importe quels autres objets tranchant. Ne pas percer ou altérer les trous d’un boitier contenant l ou composantélectrique durant l’installation.
Prepare Electrical Wiring
Save These Instructions
Use only in the manner intended by the manufacturer. If you have
any questions, contact the manufacturer.
Note: LRXD products are suitable for indoor covered ceiling
wet location applications.
Les produits de LRXD sont appropriés
pour les endroits humides couverts au plafond.
The luminaire LRXD*****MD** must be supplied with
120-277V AC, 50/60 HZ.
Connected to an individual properly grounded branch
circuit, protected by a 15 or 20 ampere circuit breaker.
Use min. 75°C supply conductor.
The grounding and bonding of the overall system shall
be done in accordance with National Electric Code
(NEC) and local codes.
Electrical Requirements
Grounding Instructions
CAUTION/ATTENTION
Fixture may fall down if not installed properly, follow installation instructions. Wear safety glasses and proper aid during installation and maintenance.
Use only UL certied wire, wire connectors, minimum 18AWG,minimum rated 75°C. Le luminaire peut tomber s’il nest pas installé correctement,suivre les
instructions d’installation.Porter des lunettes de sécurité et les aides appropriées lors del’installation et de l’entretien.N’utilisez que des ls approuvés par
UL pour les entrées/sortiesde connexion. Calibre minimum 18 AWG (0.75mm2) ettempérature minimale de 75°C.
The retrot kit is accepted as a component of a luminaire
where the suitability of the combination shall be determined
by UL or authorities having jurisdiction. Wear work gloves to
prevent dirt and oil from being transferred to the luminaire.
Lumination® LRXD Installation Guide / Manuel d’installation
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 2 of 3
(Rev 06/08/23)
IND584-Lumination-LRXD-Disk-Light-Retrofit-Install-Guide_R01
The components have been properly
packed to avoid damage during transit.
Inspect the components to conrm there
is no physical damage. Do not install
damaged components.
Retrot Kit
Light engine and junction box
Installation Instructions
Fixture Requirements Provided Components Component List
The LED retrot luminaire must be
connected to the mains supply according
to its ratings on the product label.
Luminaire Installation
Before retrot, verify that the bracket in the existing installation are
metal and are constructed similarly to the illustration at left.
Below only demonstrate the installation
procedures with round type xture.
Suitable Frame Frame Hole Suitable Fixture
Size (in.) Shape Size (in.)
4Round 4.25 - 4.90 LRXDR4xxxxx
6 Round 5.94 - 6.79 LRXDR6xxxxx
4Square 4.64 - 5.35 LRXDS4xxxxx
6 Square 6.06 - 7.32 LRXDS6xxxxx
Ensure that the power to the unit is
turned o. Use proper lockout and tagout
procedures.
Remove existing lamps, xture and ballast.
Disassemble AC conduit from the existing
junction box. Verify that the AC supply line
is provided with a ground wire connected
to the luminaire.
Secure provided junction box to the
building structure or existing frame per
local codes. If necessary, remove existing
junction box. Connect AC conduit to
provided junction box and connect the
black, white, and green/yellow wires of the
AC leads to the black, white, and green
wires using twist-own wire connectors and
close junction box.
Wire Diagram CCT Setting Switch
Optional dimmer: When connecting with
dimming controller, wires must be run
through another separate knockout hole.
Connect the violet (dimming +) and pink
(dimming -) wires to the violet and pink
wires of the xture.
NOTE: For 2700/3000/3500K model and 3500/4000/5000K model , the default CCTs
is 3000K and 3500K respectively. Lift up the cover for the switch, and use it as a tool to
choose the desired CCT.
NOTE: Please cover dimming leads with wire nuts
if you won’t connect with dimming leads.
Pink
Lumination® LRXD Installation Guide / Manuel d’installation
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 3 of 3
(Rev 06/08/23)
IND584-Lumination-LRXD-Disk-Light-Retrofit-Install-Guide_R01
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation,
operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufciently for the purchasers purposes, the
matter should be referred to Current.
Ces instructions ne prétendent pas couvrir tous les détails ou variantes de l’équipement ni couvrir toutes les conditions possibles à satisfaire en rapport avec l’installation,
l’opération ou l’entretien. Si des informations supplémentaires sont souhaitées sur des aspects qui ne sont pas sufsamment couverts pour satisfaire les besoins du client,
ou si des problèmes particuliers se présentent, veuillez addresser ces questions à Current.
Questions: l Web: LED.com l Phone/Tél: 1-866-855-8629
All product and company names are trademarks™ or registered® trademarks of their respective holders. Use of them does not imply any afliation with or endorse-
ment by them. All specications are subject to change without notice.
Tous les noms de compagnies et de produits sont des marques déposées™ ou marques enregistrées® de leurs propriétaires respectifs. Leur utilisation ne représente
aucune afliation ni aval de leur part. Toutes les spécications sont sujettes à changement sans préavis.
FCC Statements/Déclarations FCC:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class [A] RFLD complies with the
Canadian standard ICES-005. Ce DEFR de la classe [A] est
conforme à la NMB-005 du Canada.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interfer-
ence to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required
to correct the interference at his own expense.
Cet appareil est en conformité avec la section 15 des règlements de la FCC. Sa mise en service est sujette aux deux conditions suivantes : (1) Cet appareil ne
peut pas causer des interférences nuisibles, et (2) cet appareil doit accepter toute interférence reçue, y compris les interférences qui pourraient causer un
fonctionnement inadéquat. Cette classe [A] RFLD est en conformité avec la norme Canadienne ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005
du Canada.
Remarque:: Cet équipement a été testé et prouvé être en conformité avec les limites d’un appareil digital de Classe A, suivant la Section 15 des règlements
de la FCC. Ces limites sont établies pour assurer une protection raisonnable contre les interférences nuisibles lorsque l’équipement est mis en service dans
un environnement commercial. Cet équipement émet, utilise et peut radier une énergie de radio fréquence et, s’il n’est pas installé et utilisé suivant les
instructions du manuel, pourrait causer des interférences nuisibles aux communications radio. Lopération de cet équipement dans une zone résidentielle va
probablement causer des interférences nuisibles auquel cas l’utilisateur a l’obligation de corriger le problème à ses propres frais.
Load springs into upright position by
twisting the springs upward and carefully
insert the xture to the hole of the frame.
Verify the trim is ush with ceiling.
CAUTION/ATTENTION
RISK OF PERSONAL INJURY. Operators shall ensure no appendages are in the path of the
torsion springs as they are a pinch hazard when released. The springs will release when the arm
is exed downward. Be cautious that no body part is in the path of the spring when released.
RISQUE DE BLESSURE CORPORELLE. Les techniciens veilleront à ce qu’aucun appendice ne se
trouve sur le chemin des ressorts de torsion, car ils présentent un risque de pincement lorsqu’ils
sont libérés. Les ressorts seront libérés au moment de échir le bras vers le bas. Faites attention
à ce qu’aucune partie du corps ne se trouve sur le chemin du ressort à sa libération.
  • Page 1 1
  • Page 2 2
  • Page 3 3

Lumination LRXD Series Disk Downlight Retrofit Guide d'installation

Taper
Guide d'installation