Installation and Operation Instructions
Direct-Vent Linear Gas Fireplace
P/N 901226-00 REV. B 07/2023
Report No. F22-797
CUS
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a neigh-
bor’s phone. Follow the gas supplier’s instruc-
tions.
If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
AVERTISSEMENT:
RISQUED’INDENDIE OU D’EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d’entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié
ou par le fournisseur de gaz.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or
mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated
on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d’autres gaz, sauf si une trousse de conversion est utilsée.
Ce manuel est disponible en francais, simple-
ment en faire la demande. Numéro de la pièce
901226-01.
Models
P901226-00
ALLUMEDLX48TEN
ALLUME48TEN
2
General Information
901226-00B, 07/2023
Innovative Hearth Products
Allume48TEN & AllumeDLX48TEN Series Linear Direct-Vent Gas Fireplaces
DANGER
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of burns from the hot viewing glass is pro-
vided with this appliance and shall be installed for the protection of children and
other at-risk individuals.
DANGER
PELIGRO
VITRE CHAUDE
RISQUE DE BRÛLURES.
NE TOUCHEZ PAS UNE VITRE
NON REFROIDIE.
NE LAISSEZ JAMAIS UN ENFANT
DE TOUCHER LA VITRE.
EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
USTED NUNCA DEBE
TOCAR EL VIDRIO CALIENTE.
LOS NIÑOS NUNCA DEBE
TOCAR EL VIDRIO.
L’écran pare-étincelles fourni avec ce foyer réduit le risque de brûlure en cas de
contact accidentel avec la vitre chaude et doit être installé pour la protection Des
enfants et Des personnes à risques.
Se provee con este aparato una barrera de proteccion (malla), diseñada para reducir
el riesgo de quemaduras por contacto accidental con el vidrio caliente que debe
estar instalada para proteccion de infantes y otros individuos en riesgo.
Vea el volante adjunto para la representación de color adecuado
See attached color flyer for proper color representation
Voir ci-joint tract pour une bonne représentation de la couleur
SAFETY AND YOUR FIREPLACE
3
General Information
901226-00B, 07/2023
Innovative Hearth Products
Allume48TEN & AllumeDLX48TEN Series Linear Direct-Vent Gas Fireplaces
Afin d’éviter les brûlures
graves ou les blessures,
ne pas retirer l’écran de
protection de la foyer qui
empêche tout contact
direct avec la vitre.
Suivez les instructions de sécurité
ci-dessous et veillez à ce que tous
les membres de votre famille soient
conscients du danger de brûlure
encouru :
Les surfaces de votre foyer deviennent
EXTRÊMEMENT CHAUDES !
La vitre située à l'avant du foyer atteint
des températures EXTRÊMEMENT
ÉLEVÉES et peut causer de graves
blessures en cas de contact.
Tenez les enfants à l'écart du foyer
lorsqu'il fonctionne. Surveillez
attentivement les enfants dans les
pièces où un foyer est utilisé afin
d'éviter qu'ils ne soient en contact avec
la vitre.
Tenez tous les vêtements, les meubles,
l'essence et tout autre liquide
inflammable à l'écart du foyer.
Même après fermeture du gaz, les
surfaces du foyer restent extrêmement
chaudes.
Veillez à coller les Étiquettes de mise
en garde relatives à la sécurité
d'utilisation à l'endroit où vous
utilisez le foyer, pour rappeler à tous
les utilisateurs les dangers liés aux
températures élevées
(Page 40)
.
Lisez L’information de sûreté
importante (Page 4)
.
Para evitar quemaduras y lesiones
graves, no quite el protector de malla
o guardia de seguridad que evita el
contacto directo con el vidrio.
Siga las instrucciones de seguridad
a continuación y asegúrese de que
todos en su hogar sepan acerca de este
peligro de quemadura:
¡Las superficies de la chimenea
estarán EXTREMADAMANTE
CALIENTES!!
El vidrio delante de la
chimenea alcanza temperaturas
EXTREMADAMENTE ALTAS y puede
causar quemaduras graves si se toca.
Mantenga a los niños alejados de
la chimenea en funcionamiento.
Supervise en forma cercana a los niños
en cualquier cuarto donde haya una
chimenea funcionando para impedir el
contacto con el vidrio.
Mantenga la ropa, mobiliario, gasolina
y otros líquidos inflamables alejados
de la chimenea.
Aún después de haber apagado el
gas, las superficies de la chimenea
permanecen extremadamente
calientes.
Asegúrese de colocar las Etiquetas de
advertencia de seguridad de operación
en el lugar donde enciende la chimenea,
para que todos recuerden los peligros
asociados con las altas temperaturas
(Página 40)
.
Lea Información importante de
seguridad (Página 4).
Seguridad y su
chimenea
La sécurité et
votre foyer
[FRENCH][ENGLISH] [SPANISH]
Safety and Your
Fireplace
To prevent severe burns
and injuries, do Not
remove the barrier on the
appliance which prevents
direct contact with the
glass.
Follow the safety instructions below
and be sure everyone in your household
understands this burn hazard:
The surfaces on your fireplace get
EXTREMELY HOT!
The glass on the front of the
fireplace reaches EXTREMELY HIGH
temperatures and can cause severe
burns if touched.
Keep children away from an operating
fireplace. Closely supervise children
in any room where a fireplace is
operating to prevent contact with glass.
Keep clothing, furniture, gasoline, and
other flammable liquids away from the
fireplace.
Even after the gas is turned off,
fireplace surfaces remain extremely
hot.
Be sure to attach the enclosed Safety-
in-Operation Warnings where you
turn on your fireplace, to help remind
everyone of the dangers associated with
high temperatures
(Page 40)
.
Read Important Safety Information
(Page 4)
.
All parts of your
IHP fireplace get
EXTREMELY HOT!
Toutes les parties de votre
foyer IHP deviennent
EXTRÊMEMENT CHAUDES !
¡Todas las partes de la
chimenea IHP se ponen
MUY CALIENTES!
4
General Information
901226-00B, 07/2023
Innovative Hearth Products
Allume48TEN & AllumeDLX48TEN Series Linear Direct-Vent Gas Fireplaces
Important Safety Information
1. WARNING: Do not operate appliance
with the glass front removed, cracked,
or broken.
2. Do not use this appliance if any part
has been under water. Immediately
call a qualified service technician to in-
spect the appliance and to replace any
part of the control system and any gas
control which has been under water.
3. Due to high temperatures, the appli-
ance should be located out of traffic
and away from furniture and draperies.
4. Children and adults should be alerted
to the hazards of high surface tem-
perature and should stay away to avoid
burns or clothing ignition.
5. Clothing or other flammable material
should not be placed on or near the
appliance.
6. Young children should be carefully
supervised when they are in the same
room as the appliance. Toddlers,
young children, and others may be sus-
ceptible to accidental contact burns.
A physical barrier is recommended
if there are at-risk individuals in the
house. To restrict access to a fireplace
or stove, install an adjustable safety
gate to keep toddlers, young children,
and other at-risk individuals out of the
room and away from hot surfaces.
7. Any safety screen, guard or barrier
removed for servicing an appliance
must be replaced prior to operating
the appliance.
8. Installation and repair should be done
by a qualified service person. The ap-
pliance should be inspected before use
and at least annually by a professional
service person. More frequent clean-
ing may be required due to excessive
lint from carpeting, bedding material,
et cetera. It is imperative that control
compartments, burners, and circulat-
ing air passageways of the appliance
be kept clean. See maintenance in-
structions on Page 48.
L’information de sûreté
importante
1. AVERTISSEMENT. Ne pas utiliser l’appareil
si le panneau frontal en verre n’est pas en
place, est craqué ou brisé.
2. Ne pas se servir de cet appareil s’il a été
plongé dans l’eau, même partiellement.
Faire inspecter l'appareil par un technicien
qualifié et remplacer toute partie du systéme
de contrôle et toute commande qui ont été
plongées dans l'eau.
3. En raison des températures élevées,
l’appareil devrait être installé dans un en-
droit où il y a peu de circulation et loin du
mobilier et des tentures.
4. Les enfants et les adultes devraient être
informés des dangers que posent les tem-
pératures de surface élevées et se tenir à
distance afin d’éviter des brûlures ou que
leurs vêtements ne s’enflamment.
5. On ne devrait pas placer de vêtements
ni d’autres matières inflammables sur
l’appareil ni à proximité.
6. Les jeunes enfants devraient être surveillés
étroitement lorsqu’ils se trouvent dans la
même pièce que l’appareil. Les tout petits,
les jeunes enfants ou les adultes peuvent
subir des brûlures s’ils viennent en contact
avec la surface chaude. Il est recommandé
d’installer une barrière physique si des
personnes à risques habitent la maison.
Pour empêcher l’accès à un foyer ou à un
poêle, installez une barrière de sécurité
; cette mesure empêchera les tout petits,
les jeunes enfants et toute autre personne
à risque d’avoir accès à la pièce et aux
surfaces chaudes.
7. Tout écran ou protecteur retiré pour per-
mettre l’entretien de l’appareil doit être
remis en place avant de mettre l’appareil
en marche.
8. L’installation et la réparation devrait être
confiées à un technicien qualifié. L’appareil
devrait faire l’objet d’une inspection par un
technicien professionnel avant d’être utilisé
et au moins une fois l’an par la suite. Des
nettoyages plus fréquents peuvent être
nécessaires si les tapis, la literie, et cetera
produisent une quantité importante de pous-
sière. Il est essentiel que les compartiments
abritant les commandes, les brûleurs et les
conduits de circulation d’air de l’appareil
soient tenus propres. Voyez les instructions
d’entretien à la Page
48
.
Información importante de
seguridad
1. ADVERTENCIA: No opere el artefacto con el
frente de vidrio quitado, agrietado o roto.
2. No use este artefacto si alguna de sus partes
ha estado bajo agua. Llame de inmediato
a un técnico de servicio calificado para
que inspeccione el artefacto y reemplace
cualquier parte del sistema de control y
cualquier control de gas que haya estado
bajo agua.
3. Debido a las altas temperaturas, el artefacto
debe situarse fuera de las áreas de tráfico y
lejos del mobiliario y cortinas.
4. Se debe alertar a los niños y adultos sobre
los peligros de las altas temperaturas en la
superficie y que se mantengan alejados para
evitar quemaduras o ignición de la ropa.
5. No debe colocarse ropa u otros materiales
inflamables sobre y cerca del artefacto.
6. Se debe supervisar de cerca a los niños
cuando estén en el mismo cuarto que el
artefacto. Los niños pequeños, los jóvenes
y otras personas pueden ser susceptibles
a quemaduras por contacto accidental. Se
recomienda instalar una barrera física si hay
personas en riesgo en la casa. Para restringir
el acceso a una chimenea o estufa, instale
una puerta de seguridad ajustable para
mantener a los niños pequeños, jóvenes y
otras personas en riesgo fuera del cuarto y
lejos de las superficies calientes.
7. Cualquier malla o resguardo de seguridad
quitado para dar servicio a un artefacto, debe
reinstalarse antes de operar el artefacto.
8. Una persona de servicio competente debe
realizar la instalación y reparación. Una
persona de servicio profesional debe
inspeccionar el artefacto antes de usar al
menos una vez por año. Se puede requerir
limpieza más frecuente debido a la pelusa
excesiva del alfombrado, del material de
cobijas, etc. Es imprescindible mantener
limpios los compartimientos de control, los
quemadores y los pasajes de circulación del
aire del artefacto. Ver las instrucciones de
mantenimiento en la página 48.
IMPORTANT SAFETY INFORMATION
5
General Information
901226-00B, 07/2023
Innovative Hearth Products
Allume48TEN & AllumeDLX48TEN Series Linear Direct-Vent Gas Fireplaces
Safety and Your Fireplace .............................................................. 2
Important Safety Information ........................................................ 4
Safety ............................................................................................ 6
Local Codes .................................................................................. 8
Product Features ........................................................................... 8
Packaging ..................................................................................... 8
Product Identification .................................................................... 9
Requirements for the Commonwealth of Massachusetts ............. 9
Cold Climate Insulation ................................................................. 9
High Altitude Requirements ........................................................ 10
Manufactured Home Requirements ............................................ 10
Typical Locations ........................................................................ 10
Pre-installation ............................................................................ 11
Framing and Finishing ................................................................. 12
Installing TV above Fireplace ....................................................... 13
Termination Location and Clearances.......................................... 17
Venting Installation ..................................................................... 18
Thank you for your purchase. We appreciate your business!
Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information.
Following these safety, care, and operation instructions will help ensure many years of dependable and enjoyable service from your fireplace.
Please read and understand these instructions before installing or operating.
TABLE OF CONTENTS
Installation Assessories ...............................................................26
Fireplace Installation ....................................................................28
Finishing Fireplace .......................................................................37
Attaching Safety Operation Warnings ..........................................40
Operation .....................................................................................41
Cleaning and Maintenance ...........................................................48
Maintenance Schedule .................................................................50
Wiring Diagrams ..........................................................................51
Gas Conversion Kits .....................................................................53
Specifications ...............................................................................54
Technical Service .........................................................................54
Replacement Parts .......................................................................54
Service Hints ................................................................................ 54
Troubleshooting ...........................................................................55
Parts ............................................................................................56
Optional Accessories ....................................................................59
Warranty ......................................................................................61
6
General Information
901226-00B, 07/2023
Innovative Hearth Products
Allume48TEN & AllumeDLX48TEN Series Linear Direct-Vent Gas Fireplaces
WARNING
Do not slam or strike glass doors. Damage can
result in a hazardous condition.
CAUTION
Hot while in operation. Do not touch. Severe Burns may
result. Keep children, clothing furniture, gasoline and
other liquids having flammable vapors away.
ATTENTION
L’appareil est chaud lorsqu’il fonctionne. Ne pas
toucher l’appareil. Risque de brûlures graves.
Surveiller les enfants. Garder les vêtements, les
meubles, l’essence ou autres liquides produisant
des vapeur inflammables loin de l’appareil.
SAFETY
WARNING
Improper installation, adjustment, alteration,
service or maintenance can cause injury or property
damage. Refer to this manual. For assistance or
additional information consult a qualified installer,
service agency or the gas supplier.
AVERTISSEMENT
Une installation, un réglage,une modification,
une réparation ou un entretien mal effectué peut
causer des dommages matériels ou des blessures.
Voir la notice de l’utilisateur qui accompagne
l’appareil. Pour de l’aide ou des renseignements
supplémentaires, consultez un installateur, un
technicien agréé ou le fournisseur de gaz.
IMPORTANT
Read this owner’s manual carefully and completely
before trying to assemble, operate or service this
fireplace. Improper use of this fireplace can cause
serious injury or death from burns, fire, explosion,
electrical shock and carbon monoxide poisoning.
WARNING
This product can expose you to chemicals including
Carbon Black, which is known to the State of Califor-
nia to cause cancer, and Carbon Monoxide, which is
known to the State of California to cause birth defects
or other reproductive harm. For more information go
to www.P65Warnings.ca.gov
These vented gas fireplace heaters are sealed combustion, air-
circulating gas fireplaces designed for residential, manufactured
home, and commercial applications. Direct-vent appliances
operate with the combustion chamber isolated from the indoor
environment. All air for combustion is brought in from the outside,
and exhaust gases are vented through the same direct-vent, coaxial
(intake/exhaust) vent system. These fireplaces must be installed
with IHP approved Direct Vent Pipe components and terminations.
This fireplace must be installed by a qualified (certified or licensed)
service person. If the glass door assembly and venting pipe are not
properly seated, connected and sealed, carbon monoxide leakage
(spillage) can occur.
7
General Information
901226-00B, 07/2023
Innovative Hearth Products
Allume48TEN & AllumeDLX48TEN Series Linear Direct-Vent Gas Fireplaces
SAFETY Continued
WARNING
Any change to this fireplace or its controls can be
dangerous. Do not modify this fireplace under any
circumstances. Any parts removed for servicing
must be replaced prior to operating fireplace.
WARNING
Do not use a blower insert, heat exchanger insert
or other accessory not approved for use with this
fireplace.
Do not use this fireplace to cook food or burn paper
or other flammable material.
DANGER
Carbon monoxide poisoning may lead to death!
Carbon Monoxide Poisoning: Early signs of carbon monoxide poison-
ing resemble the flu, with headaches, dizziness or nausea. If you have
these signs, the fireplace may not be working properly. Get fresh air
at once! Have fireplace serviced. Some people are more affected by
carbon monoxide than others. These include pregnant women, people
with heart or lung disease or anemia, those under the influence of
alcohol and those at high altitudes.
Natural and Propane/LP Gas: Natural gas is odorless, although it has
an odor-making agent added to the gas. Propane/LP gas has a natural
odor. The odor helps you detect a gas leak. However, the odor added
to the gas can fade. Gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this
manual for reference. It is your guide to safe and proper operation
of this fireplace.
Keep the area around your fireplace clear of com-
bustible materials, gasoline and other flammable
vapor or liquids. Do not run fireplace where these
are used or stored.
This fireplace reaches high temperatures. Keep chil-
dren and adults away from hot surface to avoid burns
or clothing ignition. Fireplace will remain hot for a time
after shutdown. Allow surface to cool before touching.
1. For propane/LP fireplace, do not place propane/LP supply tank(s)
inside any structure. Locate propane/LP supply tank(s) outdoors.
To prevent performance problems, do not use propane/LP fuel
tank of less than 100 lb. capacity.
2. If you smell gas
shut off gas supply
do not try to light any appliance
do not touch any electrical switch; do not use any phone in your
building
leave the building immediately
immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier's instructions
if you cannot reach your gas supplier, call the fire department.
3. Never install the fireplace
in a recreational vehicle
in windy or drafty areas where curtains or other combustible
(flammable) objects can make contact with the fireplace front
in high traffic areas
4. Turn fireplace off and let cool before servicing, installing or
repairing. Only a qualified service person should install, service
or repair this fireplace. Have fireplace inspected annually by a
qualified service person.
5. You must keep control compartments, burners and circulating
air passages clean. More frequent cleaning may be needed due
to excessive lint and dust from carpeting, bedding material, etc.
Turn off the gas valve and pilot light before cleaning fireplace.
6. Have fireplace and venting system inspected annually by a quali-
fied service person. If needed, have venting system cleaned or
repaired. See Cleaning and Maintenance, Page 48.
7. Do not use any solid fuels (wood, coal, paper, cardboard, etc.)
in this fireplace. Use only the gas type indicated on fireplace
nameplate.
8. This appliance, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes,
with the National Electrical Code, ANSI/NFPA 70 or Canadian
Electrical Code, CSA C22.1.
9. Provide adequate clearances around air openings.
Only trim kit(s) supplied by the manufacturer shall be used in the
installation of this fireplace.
Seules des portes certifiées pour cet appareil doivent être utilisées.
If the barrier becomes damaged, the barrier shall be replaced with the
manufacturer’s barrier for this appliance
For use with barrier(s) Part No(s). F4870. Follow installation instruc-
tions.
Reinstall any barrier removed before operating the appliance. The
barrier is designed to reduce the risk of burns from hot glass. Do not
operate the appliance without the barrier installed.
8
General Information
901226-00B, 07/2023
Innovative Hearth Products
Allume48TEN & AllumeDLX48TEN Series Linear Direct-Vent Gas Fireplaces
LOCAL CODES
Install and use fireplace with care. Follow all local codes. In the ab-
sence to local codes, use the current National Fuel Gas Code ANSI
Z223.1/NFPA 54* (USA) or the current CAN/CGA B149.1 Installation
Code (Canada).
*Available from:
American National Standards Institute, Inc.
25 West 43rd Street, 4th floor
New York, NY 10036
National Fire Protection Association, Inc.
1 Batterymarch Park
Quincy, MA 02169-7471
Codes and Standards
Listing: These fireplaces comply with National Safety Standards
and are tested and listed by PFS TECO (Report No. F22-797) to
ANSI Z21.88-2019 (in Canada, CSA-2.33), and CSA 2.17-2017/
CGA 2.17 -M91 (R2014) in both USA and Canada, as vented gas
fireplace heaters.
These appliances comply with CSA P.4.1-15 “Testing Method
for Measuring Annual Fireplace Efficiency. P4 (EnerGuide) is a
measurement of the Canadian Office of Energy Efficiency.
These fireplaces are listed for installation in bedrooms, aftermarket
mobile homes, and manufactured homes.
The installation must conform to local codes or, in the absence of
local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA
54—latest edition, or the Natural Gas and Propane Installation
Code, CSA B149.1.
The fireplace, when installed, must be electrically grounded and
wired in accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70—latest
edition, or the Canadian Electrical Code, CSA C22.1—latest edition.
PRODUCT FEATURES
These are a few facts that can help you understand and enjoy your
direct vent fireplace:
The venting system may be routed to the outside of your home in
several ways. It may vent through the roof (vertical) or it may vent
to an outside/exterior wall (horizontal). The vent pipe installation is
very important to allow for proper operation. You must follow the
venting instructions very carefully for either vertical or horizontal
applications.
This fireplace may be installed in any room of your house provided
all local codes and these installation instructions are followed.
Each time you turn on your fireplace, you may notice some amount
of condensation on the inside of the fireplace glass. This is normal
and will disappear after 10-20 minutes of operation.
Your direct vent fireplace system (fireplace and venting) is a bal-
anced and sealed combustion system. It requires approximately
10-20 minutes of operating time before the flame pattern stabilizes.
PACKAGING
The assembled Direct Vent Gas Fireplace is packaged with:
Literature Kit (Installation and Operation Instructions (this
manual), Hot Glass Safety Flyer, and Safety-In-Operation Warn-
ing Labels.
Reflective Glass Media
Allume 48 - Two (2), 5 lb. bags, Black
Allume DLX48 - Two (2), 5 lb. bags, Platinum
One (1), Ecoflow Wireless Wall Switch (Allume 48)
One (1), Ecoflow Hand Held Remote (Allume DLX48)
Four (4), AA Batteries
One (1), Fireboard Top
One (1), Fireboard Bottom
Two (2), Fireboard Sides
28 Self Drill Bugle Drywall Screws (to attach Fireboard)
One (1) Heat Shield (see Figure 1)
One (1) Pipe Shield (see Figure 1)
Twelve (12) #10 Hex Head Screws
9
General Information
901226-00B, 07/2023
Innovative Hearth Products
Allume48TEN & AllumeDLX48TEN Series Linear Direct-Vent Gas Fireplaces
PRODUCT IDENTIFICATION
REQUIREMENTS FOR THE COMMONWEALTH OF
MASSACHUSETTS
These appliances are approved for installation in the U.S. state of
Massachusetts if the following additional requirements are met:
Install this fireplace in accordance with Massachusetts Rules
and Regulations 248 C.M.R. 4.00 through 8.00.
Installation and repair must be done by a plumber or gas fitter
licensed in the Commonwealth of Massachusetts.
The flexible gas line connector used shall not exceed 36” (914
mm) in length.
The individual manual shutoff must be a T-handle type valve.
Massachusetts Horizontal Vent Requirements
In the Commonwealth of Massachusetts, horizontal terminations
installed less than seven (7) ft above the finished grade must
comply with the following additional requirements:
A hard wired carbon monoxide detector with an alarm and
battery back-up must be installed on the floor level where the
gas fireplace is installed. The carbon monoxide detector must
comply with NFPA 720, be ANSI/UL 2034 listed and be CSA
certified.
A metal or plastic identification plate must be permanently
mounted to the exterior of the building at a minimum height
of eight (8) ft above grade and be directly in line with the
horizontal termination. The sign must read, in print size no
less than one-half (1/2) inch in size, GAS VENT DIRECTLY
BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS.
COLD CLIMATE INSULATION
For cold climate installations, seal all cracks around your fireplace
with noncombustible material and wherever cold air could enter
the room. It is especially important to insulate outside chase cavity
between studs and under floor on which fireplace rests, if floor
is above ground level. Gas line holes and other openings should
be caulked or stuffed with unfaced fiberglass insulation. Caulk the
firestop only where the pipe penetrates an outside wall, attic, or
other unconditioned space.
NOTE: Caulking used must have a minimum of 300°F continuous
exposure rating.
NOTE: Do not use loose, or blown-in insulation in the cavity
surrounding the fireplace.
If the fireplace is being installed on a cement slab in cold climates, a
sheet of plywood or other raised platform can be placed underneath
to prevent conduction of cold transferring to the fireplace and into
the room. It also helps to sheetrock inside surfaces and tape for
maximum air tightness and caulk firestops.
Figure 1 - Component Overview
Heatshield
Pipe Shield
Wrapper
Back
Wrapper
Side
Nailing
Flange
(4 places)
Floor
Fireplace
Stand-offs
(2 places) Flue Connector
Gas
Connection
Glass Door
Barrier
10
General Information
901226-00B, 07/2023
Innovative Hearth Products
Allume48TEN & AllumeDLX48TEN Series Linear Direct-Vent Gas Fireplaces
MANUFACTURED HOME REQUIREMENTS
This appliance may be installed in an aftermarket, permanently
located, manufactured home (USA only) or mobile home, where
not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other
gases, unless a certified kit is used.
CAUTION
Ensure that the cross members are not cut or
weakened during installation. The structural
integrity of the manufactured home floor, wall, and
ceiling / roof must be maintained.
CAUTION
This appliance must be grounded to the chassis of
the manufactured home in accordance with local
codes or in the absence of local codes, with the
National Electrical Code ANSI / NFPA 70—latest
edition or the Canadian Electrical Code CSA C22.1—
latest edition.
TYPICAL LOCATIONS
In selecting the location, the aesthetic and functional use of the
fireplace are primary concerns. However, vent system routing to
the exterior and access to the fuel supply are also important. The
fireplace may be located on or near conventional construction
materials. See Location and Space requirements Page 11 for
more information.
Due to high temperatures, the appliance should be located out of
traffic and away from furniture and draperies.
The location should also be free of electrical, plumbing or other
heating/air conditioning ducting.
Be aware that this is a heat producing fireplace. Objects placed
above the unit are exposed to elevated temperatures. Do not
insulate the space between the fireplace and the area above it.
HIGH ALTITUDE REQUIREMENTS
Orifice Sizes—Sea Level to High Altitude
These fireplaces are tested and approved for installation at
elevations of 0–4500 ft (0–1372 m) above sea level using the
standard burner orifice sizes (see specifications table, Page 54).
For elevations above 4500 ft, contact your gas supplier or qualified
service technician.
Deration
At elevations above 4500 ft, the amount of BTU fuel value delivered
must be reduced by either:
Using gas that has been derated by the gas company.
Changing the burner orifice to a smaller size as regulated
by the local authorities having jurisdiction and by the (USA)
National Fuel Gas Code NFPA 54/ANSI Z223.1—latest edition
or, in Canada, the CAN/CGA-B149.1 codes—latest edition.
IN CANADA - CSA 2.17-2017/CGA 2.17 -M91 (R2014) (HIGH
ALTITUDE):
The conversion shall be carried out by a manufacturer’s authorized
representative, in accordance with the requirements of the
manufacturer, provincial or territorial authorities having jurisdiction
and in accordance with the requirements of the CAN/CGA-B149.1
or CAN/CGA-B149.2 Installation codes.
Figure 2 - Typical Locations and Venting
NOTE: Framing details not shown. This illustrates typical locations only.
Top Vent
Top Vent
Top Vent Top Vent
Top Vent - See-Thru
Recessed
Installation
Fireplace
Fireplace Collar
Vertical
Termination
Horizontal
Termination
11
General Information
901226-00B, 07/2023
Innovative Hearth Products
Allume48TEN & AllumeDLX48TEN Series Linear Direct-Vent Gas Fireplaces
PRE-INSTALLATION
LOCATION AND SPACE REQUIREMENTS
Determine the safest and most efficient location for your direct vent fireplace.
Make sure that rafters and wall studs are not in the way of the venting system.
Choose a location where the heat output is not affected by drafts, air condi-
tioning ducts, windows or doors. Be aware of all restrictions and precautions
before deciding the exact location for your fireplace and termination cap.
When deciding the location of your fireplace, follow these rules:
Do not connect this fireplace venting to a chimney flue serving a separate
solid-fuel burning fireplace or appliance.
Due to high temperatures, do not locate this fireplace in high traffic areas,
windy or drafty areas or near furniture or draperies.
Proper clearances must be maintained.
If your fireplace is to be installed directly on carpeting, vinyl tile or any
combustible material other than wood, it must be installed on a metal or
wood panel extending the full width and depth of the fireplace (see Figure
11, Page 16).
Standoff spacers attached to your fireplace can be placed directly against
the wall or framing material. See framing details, Pages 12-16.
When locating the termination cap, it is important to observe the minimum
clearances shown in Table 2, Page 17.
Do not recess the termination cap into a wall or siding.
You may paint the termination cap with high temperature heat-resistant
paint to coordinate with the exterior finish.
There must not be any obstruction such as bushes, garden sheds, fences,
decks or utility buildings within 24" from the front of the termination cap
and the front of outside air vent.
Do not locate the termination cap and outside air vent where excessive
snow or ice build up may occur. Be sure to clear vent termination area
after snow falls to prevent accidental blockage of venting system. When
using snow blowers, do not direct snow towards vent termination area.
NOTICE
This fireplace is intended for use as supplemental heat. Use this
fireplace along with your primary heating system. Do not install this
fireplace as your primary heat source. If you have a central heat-
ing system, you may run system’s circulating blower while using
fireplace. This will help circulate the heat throughout the house.
CLEARANCES
Minimum clearances to combustibles for the fireplace are as follows:
Table 1 - Minimum Clearances
Back 3/4” (19 mm) to wrapper
Sides 1/2” (13 mm) to wrapper
0” (0 mm) to Spacers
Top of Standoffs 0” (0 mm)
Floor 0” (0 mm)
From Bottom of Unit to Ceiling 84” (2134 mm)
Enclosure Height * Vertical Penetration- 60"
Horizontal Penetration- 84"
Horizontal Vent 3” (77 mm) - Top,
1" (26 mm) - Sides and Bottom
Vertical Vent 1” (26 mm)
Front Clearance — clearance immediately
in front of viewing area(s) 36” (914 mm)
NOTE: Do not pack with insulation or other materials around the fireplace.
* No elbows allowed inside enclosure for 60" enclosure height; 60"
enclosure height requires vertical vent penetration.
Figure 3 - Standoff and Heatshield Installation
IMPORTANT! TOP STANDOFFS, HEATSHIELD, PIPE SHIELD, AND NAILING FLANGES MUST BE INSTALLED BEFORE VENTING!
1. Prepare top standoffs.
a. Identify top standoffs shipped flat on top of the fireplace (Figure 3).
b. Bend standoffs as shown and attach with supplied screws. They should measure 6-3/8" tall when installed.
2. Locate (4) nailing flanges on sides of fireplace. Loosen mounting screw and rotate 180° forward, then bend outward so that it is flush with the front
of the fireplace (Figure 3).
AFTER INSTALLING UNIT INTO FRAMING:
3. Using supplied screws, install pipe shield with mounting tab toward front of fireplace, and vertical bends toward vent collar (Figure 3).
4. Install heatshield with supplied screws (Figure 3).
View from rear
View from front
Nailing Flanges
Pipe Shield
Heatshield
Top Standoff
12
General Information
901226-00B, 07/2023
Innovative Hearth Products
Allume48TEN & AllumeDLX48TEN Series Linear Direct-Vent Gas Fireplaces
IMPORTANT! Before you begin framing, determine whether
you will be installing the fireplace as a one-sided application
or See-Thru application, with or without a HeatFlo Kit (see
Accessories, Page 59). Follow instructions included with
applicable kits and appropriate framing dimensions in this
manual.
The fireplace will come factory installed as a one sided appliance.
If you will be using the fireplace for a one sided regular application,
you can install it as is. If you will be upgrading the fireplace to a
See-Thru application a conversion kit is required (see Accessories,
Page 59). Follow instructions included with the Kit.
NOTE: The optional Blower Kit is not compatible with the Indoor See-
Thru Kit. If the Blower Kit is installed, it must be removed or disabled
when a Indoor See-Thru Kit is installed.
Floor Protection
1. Frame the fireplace as illustrated in Figures 4-9, Pages 12-15.
All framing details must allow for a minimum clearances to
combustible framing members as shown in Table 1, Page 11.
2. Mount the fireplace on the floor or on a fully supported base
extending the full width and depth of the unit. If installed
over combustible materials, such as carpeting, vinyl tile, or
combustible material other than wood flooring, the appliance
must be installed on a metal or wood panel extending the full
width and depth of the fireplace.
3. Headers may be in direct contact with the standoffs, but must
not be supported by them or notched to fit around them after self
supporting (see Figure 4). All construction above the fireplace
must be self-supporting. DO NOT use the fireplace for structural
support.
4. Figure 4, shows a typical framing of this fireplace. Figure 7,
Page 15 shows framing for HeatFlo kit installation. Figure 9,
Page 15 shows a recessed framing for HeatFlo kit installation. All
minimum clearances must be met. Vent pipe needs to maintain
1" clearance. Wood studs may be notched. Fireboard is provided
for facing around the fireplace.
5. If you are using a separate combustible mantel piece, refer to
Figure 38, Page 37 for proper installation height. You can also
install noncombustible mantel.
NOTE: Fireplace is designed for 1/2” thickness of non-combus-
tible fireboard on the face of the unit (Included with one sided
application). If installing a two sided application, the non-com-
bustible fireboard will be included with the Indoor See-Thru Kit,
see accessories Page 59).
FRAMING AND FINISHING
Framing Dimensions Standard Installation - Inches (millimeters)
A B C *E
48” Models
One Sided
Framing 55-5/8
(1413) 19-1/2
(496) 39-1/8
(994) 84
(2134)
See-Thru
Framing 55-5/8
(1413) 18-1/2
(469) 39-1/8
(994) 84
(2134)
Optional See-Thru Kit required for See-Thru installation
*
Minimum height from appliance base to ceiling
Fireplace Framing Standard Installation (Flush Wall)
Figure 4 - Framing Flush Wall (Standard Installation)
C
*E
B
A
Secure Nailing
Flanges to
Framing
Wood Header
C
13
General Information
901226-00B, 07/2023
Innovative Hearth Products
Allume48TEN & AllumeDLX48TEN Series Linear Direct-Vent Gas Fireplaces
FRAMING AND FINISHING Continued
WARNING
Ensure clearances to combustibles are maintained when building a mantel or shelves above the fireplace.
Elevated temperatures on the wall or in the air above the fireplace can cause melting, discoloration or damage
to decorations, a television (TV) or other electronic components.
IMPORTANT NOTICE
Most television manufacturers instruct the homeowner to not place the television above a heat source. Doing
so may negatively affect the longevity of the television and may negate the warranty. If you do place a
television above the fireplace, please be aware of the large amount of heat generated by the fireplace and
consider placing the television above the fireplace at 12” minimum on a flush wall and at 18" for a recessed
installation, to reduce the amount of heat that reaches the television. The homeowner must understand that
IHP does not take responsibility for any negative impact to televisions placed near this fireplace.
TVs should not be used in situations where the actual TV temperature exceeds the manufacturer’s technical
specification. Contact the TV manufacturer directly if you cannot locate this information or have questions
regarding this information.
NOTE: Clearances to TV are provided only for guidance, please follow TV manufacturer's recommendation for
installation.
INSTALLING TELEVISION (TV) ABOVE FIREPLACE
The following section details two options for installing a television (TV) above Fireplace
See Figures 6-9 for TVs Installed above the fireplace:
WIRING NOTE: If running wiring into the enclosure, use thermal insulating wrap around the wiring. Secure the wiring to protect from
contact with hot surfaces.
IMPORTANT NOTE
HeatFlo Kits allow for a recessed wall pocket above the fireplace. Follow instructions for Fireplace Framing
Dimensions for Recessed Wall Pocket.
14
General Information
901226-00B, 07/2023
Innovative Hearth Products
Allume48TEN & AllumeDLX48TEN Series Linear Direct-Vent Gas Fireplaces
FRAMING AND FINISHING Continued
*E. Minimum height from appliance base to ceiling
*F. Minimum distance from framed opening to ceiling Inches (millimeters)
Figure 6
Television (TV)
Fireplace
Ceiling
Wall
HeatFlo
Vent
Opening
B
C
A
Min. 76”
(1.930 m)
Max. 20 ft.
(6.096 m)
(A) TV Above fire-
place Opening 12 (305)
(B) TV Below Vent
Opening 3 (77)
(C) Vent Opening
Below Ceiling 4" (102)
Figure 5 - Fireplace Framing Dimensions for Flush Wall TV Installation One Sided & See-Thru Application
Minimum Dimensions for
Television (TV) Installed
Above Fireplace (Flush Wall)
*E
B
A
G
H
C
*F
Base of
Fireplace
Secure Nailing
flanges to
Framing
Wood Header
C
Framing Dimensions with HeatFlo Kit for Flush Wall TV Installation, One Sided & See-Thru Application
A B C D *E *F G H
48” Models One Sided Framing
55-5/8 (1413) 19-1/2 (496) 39-1/8 (994) 3-1/2 (89) 84 (2134) 1-1/2 (38) 53-1/2 (1359) 5-1/8 (130)
See-Thru Framing
55-5/8 (1413) 18-1/2 (469) 39-1/8 (994) 3-1/2 (89) 84 (2134) 1-1/2 (38) 53-1/2 (1359) 5-1/8 (130)
Optional See-Thru Kit required for See-Thru installation
Inches (millimeters)
15
General Information
901226-00B, 07/2023
Innovative Hearth Products
Allume48TEN & AllumeDLX48TEN Series Linear Direct-Vent Gas Fireplaces
(A) Pocket Above Fireplace Opening (Min.) 18” (457 mm)
(B) Pocket Below Vent Opening (Min.) 5-1/2” (140 mm)
(C) Vent Opening Below Ceiling 4" (102 mm)
* NOTE: Maximum pocket depth is 3-1/2” (89 mm)
FRAMING AND FINISHING Continued
Figure 9 - Dimensions for Television (TV) Installed
Above Fireplace on a Recessed Wall Pocket
Figure 7 - Fireplace Framing Dimensions for Recessed Wall Pocket TV Installation One Sided & See-Thru Application
Television (TV)
Fireplace
Ceiling
Wall
HeatFlo
Vent
Opening
B
C
A
Min. 76”
(1.930 m)
Max. 20 ft.
(6.096 m)
3" Min.
(All Sides)
Pocket *
Fireplace Framing Recessed Wall Pocket & HeatFlo Kit
(For TV Installation)
Framing Dimensions with HeatFlo Kit for Recessed Wall Pocket TV Installation One Sided & See-Thru Application - Inches (millimeters)
A B C *D *E *F G H
48” Models One Sided Framing
55-5/8 (1413) 19-1/2 (496) 39-1/8 (994) 3-1/2 (89) 84 (2134) 1-1/2 (38) 53-1/2 (1359) 5-1/8 (130)
See-Thru Framing
55-5/8 (1413) 18-1/2 (470) 39-1/8 (994) 3-1/2 (89) 84 (2134) 1-1/2 (38) 53-1/2 (1359) 5-1/8 (130)
Optional See-Thru Kit required for See-Thru installation *D Maximum allowable depth
*E. Minimum height from appliance base to ceiling *F. Minimum distance from framed opening to ceiling
Base of
Fireplace
Secure Nailing
Flanges to
Framing C
Wood Header
*F
A
B
*E
G
H
C
D
*
16
General Information
901226-00B, 07/2023
Innovative Hearth Products
Allume48TEN & AllumeDLX48TEN Series Linear Direct-Vent Gas Fireplaces
NOTE: Back wall of chase/
enclosure (including finishing
materials) shown.
F
B
A
C
D
E
7 (178)
Figure 10 - Fireplace Framing Specifications - Corner Installation with Horizontal termination
Fireplace Framing Specifications -Corner Installation with
Horizontal termination
Model A B C D E F
48” 54-1/4
(1378)
93-15/16
(2386)
66-7/16
(1688)
47
(1194)
26-11/16
(678)
1
(25)
Figure 11 - Fireplace Dimensions
Inches (millimeters)
Inches (millimeters)
Top View
Front View
Fireplace Dimensions
Model A B C D E
48” 54-1/4
(1378)
27-1/8"
(689)
46
(1168)
50-3/8
(1280)
57-7/16
(1459)
FRAMING AND FINISHING Continued
A
B
9-1/4
(235)
19-11/16
(500)
9-5/16
(237)
14-1/2
(368)
top of flue collar
32-7/8
(835)
33-5/8
(854)
C
D
E
18-5/8
(473)
20
(508)
5/8
(16) 3/4
(19)
39
(991)
Side View
17
General Information
901226-00B, 07/2023
Innovative Hearth Products
Allume48TEN & AllumeDLX48TEN Series Linear Direct-Vent Gas Fireplaces
TERMINATION LOCATION AND CLEARANCES
Table 2 - Horizontal vent termination clearances for buildings with combustible and noncombustible exteriors
Fixed
Closed Openable Fixed
Closed
V
V
VV
V
V
X
X
VX
G
G
J
F
B
B
K
H
I
A
E
L
D
B
M
C
B
V
V
A
G
G
B
TERMINATION CAP AIR SUPPLY INLET GAS METER RESTRICTED AREA
(TERMINATION PROHIBITED)
Openable
See Table 3
V
V
Inside Corner
VV
Outside Corner Recessed Location
Balcony with No Side
Wall
V
Balcony with Perpendicular Side Wall
G
F
M
M
NPO
Q
U.S. Installation ** Canadian Installation *
AClearance above grade, veranda, porch, desk, or balcony 12” (300 mm) ** 12” (300 mm) *
BClearance to window or door that may be opened 6” (150 mm)
for fireplaces < 10,000 Btu/h (3 kW),
9” (230 mm)
for fireplaces > 10,000 Btu/h (3 kW), and < 50,000 Btu/h (15
kW),
12” (300 mm)
for fireplaces > 50,000 Btu/h (15 kW) **
6” (150 mm)
for fireplaces < 10,000 Btu/h (3 kW),
12” (300 mm)
for fireplaces > 10,000 Btu/h (3 kW)
CClearance to permanently closed window 9” (229 mm)
recommended to prevent window condensation 12” (305 mm)
recommended to prevent window
condensation
DVertical clearance to ventilated soffit located above the
termination within a horizontal distance of 18” (458 mm) 18” (458 mm) 18” (458 mm)
EClearance to unventilated soffit 12” (305 mm)
30” (760 mm) to vinyl soffit 12” (305 mm)
30” (760 mm) to vinyl soffit
FClearance to outside corner 5” (127 mm)
minimum 5” (127 mm)
minimum
GClearance to inside corner 2” (51 mm) minimum 2” (51 mm) minimum
HClearance to each inside of center line extended above
meter / regulator assembly 36” (910 mm)
within a height of 15 ft above the meter / regulator assembly ** 36” (910 mm)
within a height of 15 ft above the meter /
regulator assembly *
IClearance to service regulator vent outlet 36” (910 mm)** 36” (910 mm)*
JClearance to nonmechanical air supply inlet to building or
the combustion air inlet to any other fireplace 6” (150 mm)
for fireplaces < 10,000 Btu/h (3 kW),
9” (230 mm)
for fireplaces > 10,000 Btu/h (3 kW) and < 50,000 Btu/h (15 kW),
12” (300 mm)
for fireplaces > 50,000 Btu/h (15 kW)**
6” (150 mm)
for fireplaces < 10,000 Btu/h (3 kW),
12” (300 mm)
for fireplaces > 10,000 Btu/h (3 kW)
KClearance to a mechanical air supply inlet 36” (910 mm) above if within 10 ft (3 m) horizontally ** 72” (1830 mm) *
LClearance above paved sidewalk or paved driveway located
on public property 84” (2130 mm) ‡ 84” (2130 mm) ‡
MClearance under veranda, porch, deck or balcony 12” (300 mm) *‡ 12” (300 mm) *‡
NDepth of alcove (maximum) 72” (1830 mm) ** 72” (1830 mm) *
OClearance to termination (alcove) 6” (15.2 mm) ** 6” (15.2 mm)*
PWidth of alcove (minimum) 36” (910 mm) ** 36” (910 mm) *
QClearance to combustible above (alcove) 18” (457 mm) ** 18” (457 mm) *
*
**
*‡
In accordance with the current CAN/CGA-B149.1 National Gas And Propane Installation Code
In accordance with the current ANSI Z223.1/NFPA 54 National Fuel Gas Codes
A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings
Only permitted if veranda, porch, deck, or balcony is fully-open on a minimum two sides beneath the floor
18
Innovative Hearth Products
Allume48TEN & AllumeDLX48TEN Series Linear Direct-Vent Gas Fireplaces
Installation
901226-00B, 07/2023
VENTING INSTALLATION
Approved Vent Components
These fireplaces are designed, tested and listed for operation and
installation with the following vent components only:
Secure Vent® Direct-Vent System Components,
Secure Flex® Flexible Vent Components, and
Z-FLEX® Model GA Venting Systems listed to UL1777 and
ULCS635 manufactured by Flexmaster Canada Limited.
Use only the correct size venting (4-1/2” inner and 7-1/2” outer).
These approved vent system components are labeled for identifica-
tion. DO NOT use any other manufacturer’s vent components with
these fireplaces.
The venting system must terminate on the outside of the structure
and can not be attached to a chimney or flue system serving a sepa-
rate solid fuel or gas burning appliance. A direct vent appliance must
have its own venting system. DO NOT common vent this appliance.
These models are approved to be vented either horizontally through
an outside wall or vertically through a roof or chase enclosure using
the following guidelines:
When venting system terminates horizontally on an outside wall,
you may install a standoff if the termination cap is to be installed
directly on a combustible finish such as vinyl, wood, stucco, etc.
Never run the vent downward as this may cause excessive tem-
peratures which could cause a fire.
Vent pipe air space clearances to combustibles are 1" on all sides
except on the horizontal sections, which requires 3" clearance
from the top of the pipe including horizontal terminal.
Have fireplace and selected vent components on hand to help
determine the exact measurements when elbowing or offsetting.
Always use wall firestops when penetrating walls and firestops
when penetrating ceilings or attic spaces.
INSTALLATION PRECAUTIONS
Wear gloves and safety glasses for protection
Use extreme caution when using ladders or when on roof tops
Be aware of electrical wiring locations in walls and ceilings
WARNING
Read all instructions completely and thoroughly
before attempting installation. Failure to do so
could result in serious injury, property damage or
loss of life.
WARNING
This gas fireplace and vent assembly must be vented
directly to the outside. The venting system must
NEVER be attached to a chimney serving a separate
solid fuel burning appliance. Each direct vent gas
appliance must use a separate vent system. Do not
use common vent systems.
NOTICE
Read these instructions completely before
attempting installation.
NOTICE
Failure to follow these instructions will void the
warranty
.
NOTICE
Do not seal termination cap to vent pipe. Cap must
be removable for vent inspection and maintenance.
The following actions will void the warranty on your venting
system:
Installation of any damaged venting component
Unauthorized modification of the venting system (Do not cut or alter
vent components)
Installation of any component part not manufactured or approved
by Innovative Hearth Products
Installation other than as instructed by these instructions
VENT INSTALLATION PLANNING
There are two basic types of direct vent installation:
Horizontal Termination
Vertical Termination
Horizontal Termination Installation
IMPORTANT: Horizontal terminations require only inner portion of
wall firestop.
1. Set fireplace in its desired location and determine the route your
horizontal venting will take. Do not secure fireplace until all vent-
ing has been installed. Some installations require sliding fireplace
in and out of position to make final venting connections. Figures
16-18 on Page 21 show different configurations for venting with
horizontal termination that will help you decide which application
best suits your installation. Check to see if wall studs or roof
rafters are in the path of your desired venting route. If they are,
you may want to adjust location of fireplace.
2. Direct vent pipe sections and components are designed with
special twist-lock connections.
Twist-Lock Procedure: Female ends of pipes have locking lugs
(indentations). These lugs will slide straight into matching slots
on male ends of adjacent pipes. Push pipe sections together and
twist one section clockwise approximately one-quarter turn until
sections are fully locked (see Figure 12, Page 19).
NOTE: Horizontal vent must be sloped to 1/4” per foot rise from
inlet to termination. Use non-combustible hanger straps (such
as plumbers tape) to support horizontal sections every 4 feet.
Pipe must not sag.
3. Assemble desired combination of pipe and elbows to fireplace flue
collar. If there are long portions of venting run, pre-assembled
pipe sections may be installed as subassemblies for convenience.
WARNING
Vent pipe air space clearances to combustibles
are 1" on all sides except on horizontal sections,
which require 3" clearances from the top of the
pipe including the horizontal terminal. Where the
Vertical termination cap penetrates a combustible
space, 1" air space clearance is required.
19
Innovative Hearth Products
Allume48TEN & AllumeDLX48TEN Series Linear Direct-Vent Gas Fireplaces
Installation
901226-00B, 07/2023
NOTICE
Do not seal termination cap to vent pipe. Cap must be
removable for vent inspection and maintenance.
4. Carefully determine location where vent pipe assembly will penetrate
outside wall. Mark center line of pipe on wall. Mark wall for a 12-1/8"
x 12-1/8" square hole, where bottom of square starts 5-1/8" below
center line of pipe (see Figure 13). This will provide the 3" minimum
spacing needed on top of horizontal pipe. Cut and frame 12-1/8" x
12-1/8" rectangular hole in exterior wall where vent will be termi-
nated. If wall being penetrated is constructed of noncombustible
material, such as masonry block or concrete, an 8" hole with zero
clearance is acceptable.
6. Combustible Exterior Wall: A combustible siding standoff is
required when terminating through combustible siding materials.
For vinyl siding, stucco or wood exteriors, a siding standoff may be
installed between the vent cap and the exterior wall. Siding standoff
prevents excessive heat from damaging siding materials. Siding
material must be cut to accommodate standoff. Fasten vent cap
to standoff. Apply nonhardening mastic around outside edge of
standoff. Position standoff/cap assembly over the 12-1/8" x 12-1/8"
rectangular hole and attach to exterior wall with appropriate type
fasteners for wall material (see Figure 14). Siding standoff must
sit flush against exterior fascia material.
Figure 12 - Vent Pipe Connections
Female Locking Lugs
Male Slots
VENTING INSTALLATION Continued
Firestop/Spacer (SV4.5HF) shown
on the exterior side of the wall. It
may also be installed on the
interior side.
Typical
Termination
Shown
7”
(178)
5-1/8”
(130 mm)
12-1/8”
(308 mm)
Note: Centerline of Vent Piping is
NOT the Same as the Centerline of
the Frame Opening.
6” to 48” Vent Section,
Telescopic vent section,
Elbow or Appliance Collar Base of Appliance
3”
(77 mm)
1”
(26 mm)
Adaptor
SV4.5RCH
10-1/2”
(267 mm)
*
To help minimize water infiltration
it is recommended that the Fire-
stop/ Spacer (SV4.5HF) be installed
on the exterior side of the wall.
*Recommended IHP termination kit: H1968.
**With termination kit only, 6 to 9-1/4”
To connect Vent Cap with Horizontal Vent Pipe: Slide wall firestop
over vent pipe before connecting horizontal run to vent cap
**
See Table 10 for the minimum distance
to the base of the fireplace.
Figure 13 - Installing the Horizontal Termination, SV4.5HT-2 or SV4.5HTSS
Figure 14 - Venting Connection and Exterior Wall Recessing of the Horizontal
Termination SV4.5HT-2 or SV4.5HTSS
* Use silicone caulking to seal the
top and sides of the termination,
up to the underlayment, stucco,
or masonry wall surface.
Adaptor
SV4.5RCH
**For thicknesses greater than 9-1/4"
(235mm), see Table 20.
SV4.5HT-2
Square Termination
Maximum Wall Thickness
9-1/4" (235 mm)**
Exterior Surface of Siding
Exterior Surface of
Framing
6" to 9-1/4"
(152 to 235 mm)**
1-1/4" Maximum Recess of the
Square Termination into Exterior
Finishing Material
SV4.5HT-2
Square Termination
*Caulk
*Caulk
Stucco
Siding
Interior Surface of
Finished Wall
Last Vent Section. Use
Telescopic Vent Section
(SV4.5LA), If Necessary
Maximum Extent of Vent
Run Sections Relative
to Exterior Surface of
Framing
NOTE: To help minimize water infiltration install the firestop/spacer
(SV4.5HF) on the exterior side of the wall.
5. Noncombustible Exterior Wall: Position horizontal vent cap in
enter of the 9-1/2" round hole and attach to exterior wall with four
fasteners. Before attaching vent cap to exterior wall, run a bead of
non-hardening mastic (pliable sealant) around outside edges to make
a seal between it and outside wall. NOTE: Use the appropriate
type fasteners for stucco, brick, concrete or other types of sidings.
Exterior Wall Thickness Vent Components Required
6 to 9-1/4” (152 to 235 mm) Termination Kit Only
10-3/4 to 14” (273 to 356 mm) Termination Kit and 6” Vent Section (SV4.5L6)
16-3/4 to 20” (426 to 508 mm) Termination Kit and 12” Vent Section (SV4.5L12)
11-3/4 to 20” (299 to 508 mm) Termination Kit and Telescopic Section (SV4.5LA)
and 6” vent section (SV4.5L6)
Table 3 - Venting Components Required for Various Exterior Wall Thicknesses
Carefully move fireplace, with vent assembly attached, toward wall
and insert vent pipe into horizontal termination. Pipe overlap should
be a minimum of 1-1/4". Slide wall firestop against interior wall
surface and attach with screws. Place fireplace into position and shim
with noncombustible ma-terial if needed. Nail or screw side flanges to
framing to secure unit in place.
IMPORTANT: Make sure fireplace is level before securing. If fireplace
is not level it will not work properly.
20
Innovative Hearth Products
Allume48TEN & AllumeDLX48TEN Series Linear Direct-Vent Gas Fireplaces
Installation
901226-00B, 07/2023
Figure 15A - Minimum & Maximum Venting System Requirements
5’ 10’ 15’ 20’ 25’ 30’ 35’ 40’ 45’ 50’ 55’
5’
10’
15’
20’
25’
30’
35’
40’
45’
HORIZONTAL VENT LENGTH
VERTICAL VENT HEIGHT (40’ MAX.)
Up to 3 elbows
Up to 2 elbows
Up to 1 elbows
V+H <= 55 ft
Vmax = 40 ft
V+H <= 55 ft
Vmax = 10 ft
Min Vent
Vmin = 2 ft
Hmax = 1 ft
Restrictor set to position 2 (2-1/4" opening)
Restrictor set to position 3 (1-7/16" opening)
Restrictor set to position 4 (5/8" opening)
Restrictor setting open position 1
VENTING INSTALLATION Continued
VENT SYSTEM CONFIGURATIONS - HORIZONTAL AND VERTICAL TERMINATION
NOTE: Up to 2 pieces of 3 ft Secure Flex may be used in
the configurations described above. For more combinations
of flex the maximum total run can be no more than 40 ft.
Any turns are to be treated as either 45° or 90° elbows.
NOTE: Flex is not allowed for ceiling, attic, and wall
penetrations.
NOTE: Two 45° elbows are equivalent to one 90° elbow
WARNING
Never run vent downward as this may cause excessive temperatures which could cause a fire. Operation of
improperly installed and maintained venting system could result in serious injury, property damage or loss of life.
Figure 15B - Flue Restrictor Position
Restrictor Position
IMPORTANT NOTE: Restrictor Plates should both be moved evenly when adjusted, not just one.
4 3 2Open
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62

Astria Fireplaces Allume DLX Mode d'emploi

Catégorie
Poêles
Taper
Mode d'emploi

dans d''autres langues