Extron TLP Pro 1025M Manuel utilisateur

Taper
Manuel utilisateur

Ce manuel convient également à

1
IMPORTANT:
Go to for the
complete user guide and installation
instructions before connecting the
product to the power source.
TLP Pro x25M and TLS x25M Series TouchLink® Panels
Setup Guide
Overview
The Extron TLP Pro 525M, 725M, and 1025M are three series of wall mounted, capacitive touchscreen, TouchLink panels with TFT
active matrix color LCD screens with 24-bit color depth.
The TLS 525M, 725M, and 1025M have identical features but use the Room Agent™ software to coordinate room scheduling.
The TLP Pro 525M and TLS 525M models have a 5 inch screen with a 800x480 resolution.
The TLP Pro 725M and TLS 725M models have a 7 inch screen with a 1024x600 resolution.
The TLP Pro 1025M and TLS 1025M models have a 10.1 inch screen with a 1280x800 resolution.
This guide provides instructions for experienced installers to mount and install these TouchLink panels.
Setup Checklist
Get Ready
Download and install the latest version of the following software onto the PC being used to congure the TouchLink panel:
Toolbelt — Provides device discovery, device information, rmware updates, and conguration of network settings, system
utilities, and user management for TouchLink Pro devices and scheduling panels.
TLP Pro touchpanels
GUI Designer — For designing layouts for Extron TouchLink Pro touchpanels and third party touch interfaces.
Global Configurator® Professional and Global Configurator Plus — For setting up and conguring the control processor
and TouchLink panel.
Global Scripter® — Provides an integrated development environment for Extron control systems programming.
TLS scheduling panels
Room Agent — Free room booking software for conguring the panels for room scheduling.
NOTE: All ve software programs and supporting documentation are available from www.extron.com.
Obtain the following network information from your network administrator:
DHCP status — (on or off). If DHCP is off, you must also obtain:
IP address Subnet mask Gateway
User name — This can be either admin or user.
Password — The factory congured passwords for all accounts on this device have been set to the device serial number.
Passwords can be changed during conguration. Passwords are case sensitive.
NOTE: If the device is reset to default settings, the password is the default password conguration. The default
password is extron (for either admin or user).
Make a note of the TouchLink panel MAC address, which can be found on a rear-panel label.
Mount and Cable All Devices
ATTENTION:
Do not power on the TouchLink panels until you have read the Attention in the “Rear Panel Features” section of the
TLP Pro 525, 725, and 1025 Series User Guide.
Ne branchez pas les écrans tactiles avant d’avoir lu la mise en garde dans la section «Rear Panel Features » du
TLP Pro 525, 725, and 1025 Series User Guide.
Mount the units. There are several mounting options for TouchLink panels (see Mounting on the following page).
Connect the TouchLink panel to a Power over Ethernet injector (see figure 5 on page 5).
Connect the power injector to the LAN and power it on (figure 5).
Set up the TouchLink Panels for Network Communication
Connect the PC that you are using for setup, the control processor, and the touchpanel to the same Ethernet subnetwork.
Use the Setup Menu (see page 6) or Toolbelt to set the DHCP status and, if required, network addresses for the TouchLink
panel.
www.extron.com
2
TLP Pro x25M and TLS x25M Series TouchLink panels • Setup Guide (Continued)
Configure the TouchLink Panels
TLP Pro TouchLink panels — The GUI Designer Help File, the Global Configurator Help File, and the Toolbelt Help File provide
step-by-step instructions and detailed information, including an introduction to the software and sections on how to start a project
and conguration.
Global Scripter provides an Extron-exclusive Python library (ControlScript®) and Global Scripter modules to get you started (see the
Global Scripter Help File).
TLS scheduling panels — The Room Agent Help File, User Guide, and Quick Start Guide provide information about conguring these
panels.
Mounting
All these panels can be wall-mounted, either using a UL-listed junction box, an external wall box, or directly into drywall or furniture.
Suitable mounting accessories can be found at www.extron.com.
ATTENTION:
Do not install TouchLink panels in a re resistant rated wall or partition assembly.
Veuillez ne pas installer les écrans TouchLink dans un mur protégé par un dispositif coupe-feu ou dans une cloison.
All structural steps and electrical installation must be performed by qualied personnel in accordance with local and
national building codes and electrical codes.
Toute étape structurelle et installation électrique, doit être effectuée par un personnel qualié, conformément aux
codes du bâtiment, aux codes incendie et sécurité, et aux codes électriques, locaux et nationaux.
With a Wall Box or Junction Box
Some local building codes require the TouchLink panel to be mounted in a junction box. Junction boxes or wall boxes must be
purchased separately. Figure 1 shows the TLP Pro 725M. Installation for the other panels is very similar.
NOTES:
The 5 inch models mount to a 1-gang junction box. The
US 1-gang junction box should be installed so that the
long side is horizontal. EU or MK 1-gang junction boxes
should be installed in the standard orientation.
The 7 and 10 inch models mount to a 2-gang junction
box.
Extron provides four 3/4" #6-32 Philips pan head screws
for mounting to US junction boxes
Extron provides two 16 mm M 3.5 Philips pan head
screws for mounting to MK junction boxes
EU junction boxes are usually provided with their own
screws.
With a wall box
1. Install a junction box or wall box (see gure 1, 1),
following the instructions provided by the manufacturer.
2. Fasten the mounting plate to the wallbox (2) with
the provided screws. Use the mounting holes that
are appropriate to the junction box you are using (see
figure 2 on the next page).
3. Run and connect cables to the back of the TouchLink
panel (see Rear Panel Features on page 4).
4. The mounting plate for the 5 inch TouchLink panel has
two hooks (one in each top corner). The mounting plate
for the 7 and 10 inch panels has four hooks (3), one in
each corner (see figure 2).
Position the touch panel so that the mounting slots (see
figure 4,D, on page 4) in the rear of the TouchLink
panel align with these hooks.
5. Move the TouchLink panel inward and downward so that
the panel sits securely on the hooks, and the tongue at
the bottom of the mounting plate (4) sits in the groove
in the bottom of the panel (see inset, gure 1, 5).
6. Fasten the TouchLink panel to the mounting plate with
the lock screw (6).
steps 3 through 6
TOP
e
Back View
12
3
4
5
6
4
Figure 1. Mounting the TLP Pro 725M with a Junction Box
gure 1
3
Product Category
NORTH
AMERICA
NORTH
AMERI
CA
MK
MK
EU/MK EU/MK
WALL
WALL
WALL
WALL
NORTH
AMERICA
NORTH
AMERICA
NORTH
AMERICA
NORTH
AMERICA
EU
MK
EU
EU EU
M
K
Figure 2. Mounting Plates for 5 inch models (left) and 7 or 10 inch models (right)
NOTE: The TLP Pro 725M, TLS 725M, TLP Pro 1025M, and TLS 1025M TouchLink panels use the same mounting plate.
Without a wall box
If the wall box is not required by local building codes, you can mount the TouchLink panel directly into drywall.
1. Use the mounting plate as a template to mark the wall or download the cut-out template for your product from www.extron.com.
Place the template or mounting plate against the wall or furniture in a suitable location and ensure that it is level.
2. Mark the position of the hole and cut the wall.
For the 5 inch models, this hole is 2.4 inches (61 mm) wide x 2.1 inches (53 mm) high.
For the 7 or 10 inch models, this hole is 3.5 inches (89 mm) wide x 2.0 inches (51 mm) high.
3. Mark the slots labeled WALL (5 inch models) or MK (7 or 10 inch models) (see gure 2) and drill the two pilot holes. Extron
recommends using two Molly bolts or SnapToggle bolts.
4. Secure the mounting plate to the wall (see figure 1, 2, on the previous page).
5. Complete the installation as described in steps 3 through 6 on the previous page.
gure 2
Front Panel Features
NOTE: Figure 3 shows the front panel of the TLP Pro 725M.
The front panels of all the TouchLink panels have the same
features and are almost identical apart from the size.
A Motion sensor — Detects motion between three to ve feet
from the TouchLink panel, and at least 15° from the center
axis.
If the sleep timer has been set (see Setup Menu on
page 6), and no motion has been detected for a
user-dened period of time, the TouchLink panel enters
sleep mode.
If Wake on Motion has been set (see Setup Menu), and
motion is detected by the sensor while the screen is in
sleep mode, the screen display is restored and active.
Extron
A
A
AB
B
BC
C
CA
A
A
D
D
D
E
E
E E
E
E
Figure 3. TLP Pro 725M Front Panel
B Communication LED — (TLP Pro models only) Shows the conguration and connection status of the touchpanel:
Unlit during normal operation (the touchpanel is congured and connected to an IP Link Pro control processor).
Blinks red if the touchpanel has been congured but is not connected to an IP Link Pro control processor.
Lights steadily red if the touchpanel has not been congured.
The indicator can be toggled between enabled and disabled, using the Setup Menu.
C Light sensor — Monitors ambient light level and adjusts screen brightness.
D Capacitive touchscreen
The TLP Pro 525M series and TLS 525M have a 5 inch screen with a 800x480 resolution.
The TLP Pro 725M series and TLS 725M have a 7 inch screen with a 1024x600 resolution.
The TLP Pro 1025M series and TLS 1025M have a 10.1 inch screen with a 1280x800 resolution.
gure 3
4
TLP Pro x25M and TLS x25M Series TouchLink panels • Setup Guide (Continued)
Rear Panel Features
D
D
D
C
C
CA
A
AB
B
B
E
E
E
J
J
JH
H
H
TLP Pro 525M I
I
I
G
G
G
D
D
D
C
C
CA
A
AB
B
B
E
E
E
F
F
F
G
G
G
H
H
HI
I
I J
J
J
K
K
K
D
D
D
D
D
D
D
D
D
D
D
D
TLP Pro 725M
F
F
F
C
C
CA
A
AB
B
BH
H
H
H
H
H
E
E
E
F
F
F
G
G
G
D
D
D
D
D
D
K
K
K
D
D
D
D
D
D
I
I
I J
J
JTLP Pro 1025M
Figure 4. TLP Pro 525M, 725M, and 1025M Rear Panels
gure 4
NOTES:
The panels shown in gure 4 are for illustration
only and are not to the same scale.
The TLS models have the same rear panel
features as the corresponding TLP Pro models.
For more information, follow these links to the next page.
AMENU Button
BRESET Button
CRESET LED
DMounting Slots
EDigital Input Monitoring Port
FLAN/PoE Connector
GUSB Port
HSpeaker
ISlot for Mounting Plate
JMounting Screw
KRear Panel Status Lights
E Status lights — Two LED light bars, one on either side of the screen (see figure 3 on the previous page).
TLS models — The LEDs light green when the room is currently available and red when the room is currently booked. They
cannot be programmed.
TLP Pro models — The LEDs can be congured to light red or green and to blink or light continuously, to provide system
feedback (see the Global Configurator Help File and Global Scripter Help File).
5
Product Category
A MENU Button (see figure 4 on the previous page)— Activates the setup menu (see Setup Menu on the next page).
B RESET Button — Pressing the Reset button allows the unit to be reset in any of three different modes (for an overview, see
Reset Modes, on the next page).
C RESET LED — Provides feedback about the reset status when the user presses the Reset button (see Reset Modes).
D Mounting Slots — The TLP Pro 725M and TLP Pro 1025M have four, one in each corner. The TLP Pro 525M has two, one in each
top corner. The hooks on the corners of the mounting plate (see figure 1, 3 on page 2) t into these slots for wall mounting.
E Digital Input Monitoring Port — This two-pole captive screw port (1 = signal and G = ground) monitors digital input with or
without a +5 VDC pull-up.
F LAN/PoE Connector — Connect the TouchLink panel to a PoE power injector (not provided) using a twisted pair cable,
terminated with an RJ-45 connector. Connect the power injector to the LAN through a nework switch. An Extron IP Link Pro
control processor must also be connected to the same network as the TouchLink Pro touchpanel. TLS models do not require a
control processor
ATTENTION:
The TouchLink panels are Power over Ethernet (PoE 802.3af, class 3) compliant. Do not power on the touchpanels
until you have read the Attention in the “Rear Panel Features” section of the TLP Pro 525, 725, and 1025 Series
User Guide.
Les écrans TouchLink supportent l’alimentation via Ethernet (PoE 802.3af, classe 3). Veuillez lire la partie
« Attention » dans la section « Rear Panel Features » du TLP Pro 525, 725, and 1025 Series User Guide, avant de
mettre sous tension les écrans tactiles.
NOTE: These TouchLink panels are shipped without a power
injector. The power injector must be purchased separately.
MENU Button
RESET Button
RESET LED
Mounting Slots
Digital Input Monitoring Port
LAN/PoE Connector
Extron recommends the Extron XTP PI 100 power injector (see gure 5).
Your power injector may look different.
G USB Port — Compatible with USB 2.0.
H Speaker — Provides audible feedback for the user.
TLP Pro 525M and TLS 525M — a single speaker.
TLP Pro 725M and TLS 725M — a single speaker.
TLP Pro 1025M and TLS 1025M — two (dual mono) speakers.
USB Port
Speaker
100-240V
~
50-60Hz
0.4A MAX
XTP
PWR
XTP PWR
To network switchTo TouchLink panel
Figure 5. XTP PI 100 Power Injector
gure 5
I Slot for Mounting Plate — The tongue at the bottom of the mounting plate (see figure 1, 4) ts into this slot, for wall mounting.
J Mounting Screw — Tightens against the tongue of the mounting plate to secure the TouchLink panel.
K Rear Panel Status Lights — These lights can be disabled for glass mount applications.
TLP Pro 525M and TLS 525M — no lights.
TLP Pro 725M and TLS 725M — Six lights, three on each side of the panel.
TLP Pro 1025M and TLS 1025M — Two lights, one on each side of the panel.
TLS models — The LEDs light green when the room is currently available and red when the room is currently booked. They
cannot be programmed.
TLP Pro models — The LEDs can be congured to light red or green and to blink or light continuously, to provide system
feedback.
The rear panel status lights can be toggled between enabled and disabled by using the Setup Menu (see the next page).
For information about programming these LEDs for the TLP Pro x25M models, see the Global Configurator Help File and Global
Scripter Help File.
Mounting Screw
Slot for Mounting Plate
Rear Panel Status Lights
6
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the
Extron Safety and Regulatory Compliance Guide on the Extron website.
© 2020 - 2023 Extron Electronics — All rights reserved. www.extron.com
All trademarks mentioned are the property of their respective owners.
Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876
TLP Pro x25M and TLS x25M Series TouchLink panels • Setup Guide (Continued)
Reset Modes: a Brief Summary
These TouchLink panels provide the following reset modes (see the TLP Pro 525, 725, and 1025 Series User Guide for complete
information):
Use Factory Firmware — With the unit powered off, press and hold the RESET button (see figure 4, B on page 4) while
reapplying power to the unit. Use this mode with Toolbelt software to replace rmware in the event of conicts arising from
uploading a rmware update.
Reset All IP Settings — Press and hold the RESET button for 6 seconds. After the RESET LED (C) blinks twice, release and
momentarily press the RESET button. Use this mode to reset all network settings without affecting user-loaded les.
Reset to Factory Defaults — Press and hold the RESET button for 9 seconds. After the RESET LED blinks three times,
release and momentarily press the RESET button. Use this mode to return the TouchLink panel to factory default settings.
NOTES:
The factory congured passwords for all accounts on this device have been set to the device serial number.
Passwords are case sensitive.
If the device is reset to default settings, the password will be the default password conguration. The default
password is extron (for either admin or user).
Enable or Disable the DHCP Client — This mode toggles between DHCP enabled and DHCP disabled. Press the RESET
button ve times, consecutively. After the fth press, do not press the button again within 3 seconds. If DHCP was enabled, it
is now disabled and the Power LED blinks three times. If DHCP was disabled, it is now enabled and the Power LED blinks six
times.
Reset Modes
Status DisplayAudioAdvanced Exit
Network
Info
Model: TLP Pro 725M
Part Number: 60-1563-02
Firmware
Version:3.09.0000-b002
Network
IP Address:
DHCP:
Host Name:
Off
192.168.254.251
TLP-AB-CD-EF
Display
Resolution:
GUI Project:
Sleep Timer:
800x480
N/A
5 Minutes
Audio
System Volume:
System Mute:Off
99
Advanced
Controller IP:N/A
Project Size:N/A
Bootloader
Version:1.00.0002
LinkLicenses
LinkLicenses
User Interface
System Information
Primary Controller Address:
N/A
System ID:N/A
Edit
LinkLicense for TLP Pro Control Processor
Figure 6. Setup Menu: Status Screen for TLP Pro 725M
Setup Menu
Figure 6 shows the Status screen for the TLP Pro 725M. The
screen for the TLP Pro 525M, TLP Pro 1025M, and the TLS
models are similar.
Press the MENU button (figure 4, A) to open the setup menu.
The Status screen shows seven panes. The Status, Network,
Display, Audio, and Advanced screens can be accessed by
pressing the appropriate button in the navigation bar at the top
of the screen or clicking on the corresponding pane of the Status
screen.
System Information allows the touchpanel to be connected
to a control processor. Toggle the LinkLicenses switch
to allow the device to function as a touchpanel or a control
processor. These two functions can be accessed from the
Status page of the setup menu. (For more information, see the
TLP Pro 525, 725, and 1025 Series User Guide).
68-2831-55 Rev. C
05 23
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Extron TLP Pro 1025M Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues