Simplicity 030342-00 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur
PRO4000 Portable Generator
Operator’s Manual
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
JEFFERSON, WISCONSIN, U.S.A.
Manual No. 203336GS Revision A (04/17/2007)
Briggs & Stratton Power Products Group, LLC
900 North Parkway
Jefferson, WI 53549
Copyright © 2007 Briggs & Stratton Power Products Group,
LLC. All rights reserved. No part of this material may be
reproduced or transmitted in any form by any means without
the express written permission of Briggs & Stratton Power
Products Group, LLC.
Thank you for purchasing this quality-built Briggs & Stratton generator. We are pleased that you’ve placed your confidence in
the Briggs & Stratton brand. When operated and maintained according to the instructions in this manual, your Briggs &
Stratton generator will provide many years of dependable service.
This manual contains safety information to make you aware of the hazards and risks associated with generators and how to
avoid them. This generator is designed and intended only for supplying electrical power for operating compatible electrical
lighting, appliances, tools and motor loads, and is not intended for any other purpose. It is important that you read and
understand these instructions thoroughly before attempting to start or operate this equipment. Save these instructions for
future reference.
This generator requires final assembly before use. Refer to the Assembly section of this manual for instructions on final
assembly procedures. Follow the instructions completely.
Where to Find Us
You never have to look far to find Briggs & Stratton support and service for your generator. Consult your Yellow Pages. There
are over 30,000 Briggs & Stratton authorized service dealers worldwide who provide quality service. You can also contact
Briggs & Stratton Customer Service by phone at (800) 743-4115, or on the Internet at BRIGGSandSTRATTON.COM.
Generator
Model Number
Revision
Serial Number
Engine
Model Number
Type Number
Code Number
Date Purchased
1
FrançaisEspañol
Table of Contents
Operator Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Equipment Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Unpack Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Shipment Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Install Wheel Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Add Engine Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Add Fuel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
System Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Connecting to a Building’s Electrical System. . . . . . . . . . . . . . . . . . . . . . . . 7
Generator Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Features and Controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Cord Sets and Receptacles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Ground Fault Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Starting the Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Connecting Electrical Loads. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Stopping the Engine. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Operating Automatic Idle Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Oil Pressure Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Charging a Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Cold Weather Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Don’t Overload Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Maintenance Schedule. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Generator Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Fuel Valve Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Engine Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Warranties. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Emissions Control System Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Generator Owner Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Product Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Common Service Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
1
2 BRIGGSandSTRATTON.COM
SAVE THESE INSTRUCTIONS
Operator Safety
Equipment Description
Read this manual carefully and become familiar
with your generator. Know its applications, its
limitations and any hazards involved.
The generator is an engine–driven, revolving field, alternating
current (AC) generator. It was designed to supply electrical
power for operating compatible electrical lighting, appliances,
tools and motor loads. The generator’s revolving field is
driven at about 3,600 rpm by a single-cylinder engine.
This generator incorporates GFCI (Ground Fault Circuit
Interrupter) outlet protection and has its neutral bonded to
ground to comply to OSHA inspections on job sites. This
generator will not function when connected to a 2 pole
transfer switch since the home or building main breaker box
also has a neutral bonded to ground. When both the
generator and the home or building breaker box contains a
neutral bonded to ground, the generators GFCI will open and
no outlets will function.
Every effort has been made to ensure that the information in
this manual is both accurate and current. However, the
manufacturer reserves the right to change, alter or otherwise
improve the generator and this documentation at any time
without prior notice.
The Emission Control System for this generator is warranted
for standards set by the Environmental Protection Agency
and the California Air Resources Board.
Safety Rules
This is the safety alert symbol. It is used to alert
you to potential personal injury hazards. Obey all
safety messages that follow this symbol to avoid
possible injury or death.
The safety alert symbol ( ) is used with a signal word
(DANGER, WARNING, CAUTION), a pictorial and/or a safety
message to alert you to hazards. DANGER indicates a hazard
which, if not avoided, will result in death or serious injury.
WARNING indicates a hazard which, if not avoided, could
result in death or serious injury. CAUTION indicates a hazard
which, if not avoided, might result in minor or moderate
injury. NOTICE indicates a situation that could result in
equipment damage. Follow safety messages to avoid or
reduce the risk of injury or death.
The manufacturer cannot possibly anticipate every possible
circumstance that might involve a hazard. The warnings in
this manual, and the tags and decals affixed to the unit are,
therefore, not all-inclusive. If you use a procedure, work
method or operating technique that the manufacturer does
not specifically recommend, you must satisfy yourself that it
is safe for you and others. You must also make sure that the
procedure, work method or operating technique that you
choose does not render the generator unsafe.
Hazard Symbols and Meanings
A - Explosion G - Flying Objects
B - Fire H - Explosive Pressure
C - Electric Shock J - Chemical Burn
D - Toxic Fumes K - Moving Parts
E - Kickback L - Read Manual
F - Hot Surface
A B C
D E
G H
F
J
K L
NOTICE
Exceeding generators wattage/amperage capacity can
damage generator and/or electrical devices connected to it.
DO NOT exceed the generator’s wattage/amperage capacity. See
Don’t Overload Generator in the Operation section.
WARNING
Removing the neutral bond could result in death,
bodily injury and/or property damage.
DO NOT remove the neutral bond.
3
WARNING
The engine exhaust from this product contains
chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
WARNING
Running engine gives off carbon monoxide, an
odorless, colorless, poison gas.
Breathing carbon monoxide can cause headache,
fatigue, dizziness, vomiting, confusion, seizures,
nausea, fainting or death.
Operate generator ONLY outdoors.
Install a battery operated carbon monoxide alarm near the
bedrooms.
Keep exhaust gas from entering a confined area through
windows, doors, ventilation intakes, or other openings.
DO NOT start or run engine indoors or in an enclosed area,
(even if windows and doors are open), including the generator
compartment of a recreational vehicle (RV).
WARNING
Starter cord kickback (rapid retraction) can result
in bodily injury. Kickback will pull hand and arm
toward engine faster than you can let go.
Broken bones, fractures, bruises, or sprains
could result.
When starting engine, pull cord slowly until resistance is felt and
then pull rapidly to avoid kickback.
NEVER start or stop engine with electrical devices plugged in
and turned on.
WARNING
Fuel and its vapors are extremely flammable and
explosive.
Fire or explosion can cause severe burns or
death.
WHEN ADDING OR DRAINING FUEL
Turn generator OFF and let it cool at least 2 minutes before
removing fuel cap. Loosen cap slowly to relieve pressure in
tank.
Fill or drain fuel tank outdoors.
DO NOT overfill tank. Allow space for fuel expansion.
If fuel spills, wait until it evaporates before starting engine.
Keep fuel away from sparks, open flames, pilot lights, heat, and
other ignition sources.
DO NOT light a cigarette or smoke.
WHEN STARTING EQUIPMENT
Ensure spark plug, muffler, fuel cap, and air cleaner are in place.
DO NOT crank engine with spark plug removed.
WHEN OPERATING EQUIPMENT
DO NOT tip engine or equipment at angle which causes fuel to
spill.
This generator is not for use in mobile equipment or marine
applications.
WHEN TRANSPORTING OR REPAIRING EQUIPMENT
Transport/repair with fuel tank EMPTY or with fuel shutoff valve
OFF.
Disconnect spark plug wire.
WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK
Store away from furnaces, stoves, water heaters, clothes dryers,
or other appliances that have pilot light or other ignition source
because they can ignite fuel vapors.
WARNING
This generator does not meet U. S. Coast Guard Regulation
33CFR-183 and should not be used on marine applications.
Failure to use the appropriate U. S. Coast Guard approved
generator could result in death or serious injury and/or
property damage.
DANGER
Storage batteries give off explosive hydrogen
gas during recharging.
Hydrogen gas stays near battery for a long time
after battery has been charged.
Slightest spark will ignite hydrogen and cause
explosion.
You can be blinded or severely injured.
Battery electrolyte fluid contains acid and is
extremely caustic.
Contact with battery fluid will cause severe
chemical burns.
DO NOT allow any open flame, spark, heat, or lit cigarette during
and for several minutes after charging a battery.
Wear protective goggles, rubber apron, and rubber gloves.
4 BRIGGSandSTRATTON.COM
WARNING
Contact with muffler area can result in serious
burns.
Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.
DO NOT touch hot parts and AVOID hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 5 feet (1.5 m) of clearance on all sides of
generator including overhead.
Code of Federal Regulation (CFR) Title 36 Parks, Forests, and
Public Property require equipment powered by an internal
combustion engine to have a spark arrester, maintained in
effective working order, complying to USDA Forest service
standard 5100-1C or later revision. In the State of California a
spark arrester is required under section 4442 of the California
Public resources code. Other states may have similar laws.
WARNING
Unintentional sparking can result in fire or
electric shock.
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR
Disconnect the spark plug wire from the spark plug and place
the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
Use approved spark plug tester.
DO NOT check for spark with spark plug removed.
WARNING
Starter and other rotating parts can entangle
hands, hair, clothing, or accessories.
NEVER operate generator without protective housing or covers.
DO NOT wear loose clothing, jewelry or anything that may be
caught in the starter or other rotating parts.
Tie up long hair and remove jewelry.
CAUTION
Excessively high operating speeds increase risk of injury
and damage to generator.
Excessively low speeds impose a heavy load.
DO NOT tamper with governed speed. Generator supplies
correct rated frequency and voltage when running at governed
speed.
DO NOT modify generator in any way.
NOTICE
Improper treatment of generator can damage it and
shorten its life.
Use generator only for intended uses.
If you have questions about intended use, ask dealer or contact
local service center.
Operate generator only on level surfaces.
DO NOT expose generator to excessive moisture, dust, dirt, or
corrosive vapors.
DO NOT insert any objects through cooling slots.
If connected devices overheat, turn them off and disconnect
them from generator.
Shut off generator if:
-electrical output is lost;
-equipment sparks, smokes, or emits flames;
-unit vibrates excessively.
NOTICE
Exceeding generators wattage/amperage capacity can
damage generator and/or electrical devices connected to it.
DO NOT exceed the generator’s wattage/amperage capacity. See
Don’t Overload Generator in the Operation section.
Start generator and let engine stabilize before connecting
electrical loads.
Connect electrical loads in OFF position, then turn ON for
operation.
Turn electrical loads OFF and disconnect from generator before
stopping generator.
WARNING
Generator produces hazardous voltage.
Failure to isolate generator from power utility
can result in death or injury to electric utility
workers due to backfeed of electrical energy.
When using generator for backup power, notify utility company.
Use approved transfer equipment to isolate generator from
electric utility.
Use a ground fault circuit interrupter (GFCI) in any damp or
highly conductive area, such as metal decking or steel work.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords which are worn,
frayed, bare or otherwise damaged.
DO NOT operate generator in the rain or wet weather.
DO NOT handle generator or electrical cords while standing in
water, while barefoot, or while hands or feet are wet.
DO NOT allow unqualified persons or children to operate or
service generator.
5
Assembly
Your generator requires some assembly and is ready for use
after it has been properly serviced with the recommended oil
and fuel.
If you have any problems with the assembly of your generator,
please call the generator helpline at 1-800-743-4115. If calling
for assistance, please have the model, revision, and serial
number from the data tag available. See Generator Controls
and Features for data tag location.
Unpack Generator
1. Set the carton on a rigid, flat surface.
2. Remove everything from carton except generator.
3. Open carton completely by cutting each corner from
top to bottom.
4. Leave generator on carton to install wheel kit.
Shipment Contents
The generator is supplied with:
Engine oil
Operator’s manual
Battery charge cables
Wheel kit
120/240 Volt, 20 Amp locking plug
120 Volt, 30 Amp locking plug
Install Wheel Kit
NOTE: Wheel kit is not intended for over-the-road use.
You will need the following tools to install these
components:
1/2” or 13 mm and 7/16” wrench
Socket wrench with a 9/16” or 14 mm and a 7/16”
socket
Pliers
Safety glasses
Install the wheel kit as follows:
1. Tip generator so that engine end is up.
2. Slide axle (A) through both mounting brackets.
3. Slide a wheel (B) over axle.
NOTE: Be sure to install both wheels with the air inflation
valve on the outboard side.
4. Place a washer (C) on axle and then place an e-ring
(D) in axle groove.
5. Install e-ring with pliers, squeezing from top of e-ring
to bottom of axle.
6. Repeat steps 3 through 5 to secure second wheel.
CAUTION
E-rings can cause eye injury.
E-rings can spring back and become airborne
when installing or removing.
Always wear eye protection when installing/removing e-rings.
B
C
D
T
A
K
L
E
G
H
M
F
N
S
P
R
J
7. Attach vibration mounts (E) to support leg (F) with
1/4-20 x 1” capscrews (G) and 1/4-20 lock nuts (H).
8. Tip generator so that engine side is down.
9. Remove existing hardware (J) from left unit vibration
mount with 13mm wrench. Use same hardware to
attach support leg.
10. Attach other side of support leg with a M8 x 20 mm
capscrew (K) and M8 lock nut (L).
11. Attach handle (M) to bracket on generator frame as
shown, with a 50 mm capscrew (N), flat washers (P),
nylon washers (R), and M8 lock nut (S).
NOTE: DO NOT overtighten. Handle must be able to move up
and down freely.
12. Return generator to normal operating position (resting
on wheels and support leg).
13. Loop handle pin (T) on generator frame just above
handle bracket.
14. Raise handle and insert handle pin to move generator.
15. Check that tires are inflated to value marked on tire or
within 15 and 40 psi.
Add Engine Oil
1. Place generator on a flat, level surface.
2. Clean area around oil fill and remove yellow oil fill cap.
NOTE: See the section Oil to review oil recommendations.
Verify provided oil bottle is correct viscosity for current
ambient temperature.
3. Using oil funnel (optional), slowly pour contents of
provided oil bottle into oil fill opening.
4. Replace oil fill cap and fully tighten.
Add Fuel
Fuel must meet these requirements:
Clean, fresh, unleaded gasoline.
A minimum of 87 octane/87 AKI (91 RON). High
altitude use, see High Altitude.
Gasoline with up to 10% ethanol (gasohol) or up to
15% MTBE (methyl tertiary butyl ether) is acceptable.
To protect the fuel system from gum formation, mix in a fuel
stabilizer when adding fuel. See Storage. All fuel is not the
same. If you experience starting or performance problems
after using fuel, switch to a different fuel provider or change
brands. This engine is certified to operate on gasoline. The
emission control system for this engine is EM (Engine
Modifications).
1. Clean area around fuel fill cap, remove cap.
2. Slowly add unleaded gasoline (A) to fuel tank (B). Be
careful not to fill above the baffle (C). This allows
adequate space for fuel expansion as shown.
3. Install fuel cap and let any spilled fuel evaporate before
starting engine.
High Altitude
At altitudes over 5,000 feet (1524 meters), a minimum
85 octane / 85 AKI (89 RON) gasoline is acceptable. To
remain emissions compliant, high altitude adjustment is
required. Operation without this adjustment will cause
decreased performance, increased fuel consumption, and
increased emissions. See a Briggs & Stratton Authorized
Dealer for high altitude adjustment information. Operation of
the engine at altitudes below 2,500 feet (762 meters) with
the high altitude kit is not recommended.
FUEL
TANK
C
B
A
6 BRIGGSandSTRATTON.COM
NOTICE
Improper treatment of generator can damage it and
shorten its life.
DO NOT attempt to crank or start the engine before it has been
properly serviced with the recommended oil. This may result in
an engine failure.
NOTICE
Avoid generator damage.
Failure to follow Operator’s Manual for fuel
recommendations voids warranty.
DO NOT use unapproved gasoline such as E85.
DO NOT mix oil in gasoline.
DO NOT modify engine to run on alternate fuels.
WARNING
Fuel and its vapors are extremely flammable and
explosive.
Fire or explosion can cause severe burns or
death.
WHEN ADDING FUEL
Turn generator OFF and let it cool at least 2 minutes before
removing fuel cap. Loosen cap slowly to relieve pressure in
tank.
Fill fuel tank outdoors.
DO NOT overfill tank. Allow space for fuel expansion.
If fuel spills, wait until it evaporates before starting engine.
Keep fuel away from sparks, open flames, pilot lights, heat, and
other ignition sources.
DO NOT light a cigarette or smoke.
7
System Ground
The generator has a system ground that connects the
generator frame components to the ground terminals on the
AC output receptacles. The system ground is connected to
the AC neutral wire (the neutral is bonded to the generator
frame).
Special Requirements
There may be Federal or State Occupational Safety and
Health Administration (OSHA) regulations, local codes, or
ordinances that apply to the intended use of the generator.
Please consult a qualified electrician, electrical inspector, or
the local agency having jurisdiction:
In some areas, generators are required to be registered
with local utility companies.
If the generator is used at a construction site, there
may be additional regulations which must be observed.
Connecting to a Building’s Electrical System
Connections for standby power to a building’s electrical
system must be made by a qualified electrician. The
connection must isolate the generator power from utility
power or other alternative power sources and must comply
with all applicable laws and electrical codes.
Generator Location
Clearances and Air Movement
Place generator outdoors in an area that will not accumulate
deadly exhaust gas. DO NOT place generator where exhaust
gas (A) could accumulate and enter inside or be drawn into
a potentially occupied building. Ensure exhaust gas is kept
away from any windows, doors, ventilation intakes, or other
openings that can allow exhaust gas to collect in a confined
area. Prevailing winds and air currents should be taken into
consideration when positioning generator.
WARNING
Generator produces hazardous voltage.
Failure to isolate generator from power utility
can result in death or injury to electric utility
workers due to backfeed of electrical energy.
When using generator for backup power, notify utility company.
Use approved transfer equipment to isolate generator from
electric utility.
Use a ground fault circuit interrupter (GFCI) in any damp or
highly conductive area, such as metal decking or steel work.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords which are worn,
frayed, bare or otherwise damaged.
DO NOT operate generator in the rain or wet weather.
DO NOT handle generator or electrical cords while standing in
water, while barefoot, or while hands or feet are wet.
DO NOT allow unqualified persons or children to operate or
service generator.
WARNING
Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.
Keep at least 5 ft. (1.5 m) clearance on all sides of generator
including overhead.
A
8 BRIGGSandSTRATTON.COM
Features and Controls
Read this Operator’s Manual and safety rules before operating your generator.
Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and
adjustments. Save this manual for future reference.
A
C
E
F
M
N
L
D
K
A - Fuel Tank — Capacity of four and a half (4.5) U.S. gallons.
B - Hour Meter — Displays and records how many hours
your generator has run (up to 9,999.9).
C - 12 Volt DC Receptacle — Use this receptacle with
battery charge cables to charge a 12 Volt battery.
D - Idle Control Switch — Use this switch to turn the idle
control feature on and off.
E - 120 Volt AC, 20 Amp Duplex Receptacle — May be
used to supply electrical power for the operation of
120 Volt AC, 20 Amp, single phase, 60 Hz electrical
lighting, appliance, tool and motor loads.
F - 120 Volt AC, 30 Amp Locking Receptacle — May be
used to supply electrical power for the operation of
120 Volt AC, 30 Amp, single phase, 60 Hz electrical
lighting, appliance, tool and motor loads.
G - 120/240 Volt AC, 20 Amp Locking Receptacle — May
be used to supply electrical power for the operation of
120 and/or 240 Volt AC, 20 Amp, single phase, 60 Hz
electrical lighting, appliance, tool and motor loads.
H - GFCI Circuit Breaker — A GFCI circuit breaker is
provided to protect against electrical ground fault and
protect the generator against electrical overload.
J - Grounding Fastener — If required, please consult a
qualified electrician, electrical inspector, or local agency
having jurisdiction.
K - Data Tag – Provides model, revision and serial number
of generator. Please have these readily available if calling
for assistance.
L - Spark Arrester Muffler — Exhaust muffler lowers engine
noise and is equipped with a spark arrester screen.
M - Air Cleaner — Protects engine by filtering dust and
debris out of intake air.
N - Choke Lever — Used when starting a cold engine.
Items Not Shown:
Engine Identification — Provides model, type and code of
engine. Please have these readily available if calling for
assistance.
Fuel Valve Used to turn fuel supply on and off to engine.
Oil Drain Plug — Drain engine oil here.
Oil Fill Cap/Dipstick — Check and add engine oil here.
Recoil Starter — Used to start the engine.
Rocker Switch — Set this switch to run (I) before using
recoil starter. Set switch to stop (O) to stop engine.
G
H
J
B
Cord Sets and Receptacles
Use only high quality, well-insulated, grounded extension
cords with the generator’s 120 Volt duplex receptacle.
Inspect extension cords before each use.
Check the ratings of all extension cords before you use
them. Extension cord sets used should be rated for 125 Volt
AC loads at 20 Amps or greater for most electrical devices.
Some devices, however, may not require this type of
extension cord. Check the operator’s manuals of those
devices for the manufacturer’s recommendations.
Keep extension cords as short as possible to minimize
voltage drop.
120/240 Volt AC, 20 Amp, Locking Receptacle
Use a NEMA L14-20 plug with this receptacle. Connect a
4-wire cord set rated for 250 Volt AC loads at 20 Amps (or
greater). You can use the same 4-wire cord if you plan to run
a 120 Volt load.
This receptacle powers 120/240 Volt AC, 60 Hz, single phase
loads requiring up to 4,000 watts of power (4.0 kW) at
16.6 Amps for 240 Volts or two independent 120 Volt loads
at 16.6 Amps each. The outlet is protected by a 2 pole GFCI
circuit breaker.
120 Volt AC, 30 Amp Locking Receptacle
Use a NEMA L5–30 plug with this receptacle. Connect a
3–wire cord set rated for 125 Volt AC loads at 30 Amps to
the plug.
Use this receptacle to operate 120 Volt AC, 60 Hz, single phase
loads requiring up to 3,600 watts (3.6 kW) of power at 30
Amps. The outlet is protected by a 2 pole GFCI circuit breaker.
120 Volt AC, 20 Amp, Duplex Receptacles
The duplex receptacle is protected against overload by a
2 pole GFCI circuit breaker.
Use each receptacle to operate 120 Volt AC, single-phase,
60 Hz electrical loads requiring up to 2,400 watts (2.4 kW) at
20 Amps of current. Use cord sets that are rated for 125 Volt
AC loads at 20 Amps (or greater). Inspect cord sets before
each use.
12 Volt DC, 10 Amp Receptacle
This receptacle allows you to recharge a 12 Volt automotive
or utility style storage battery with the battery charge cables
provided.
This receptacle can not recharge 6 Volt batteries and can not
be used to crank an engine having a discharged battery. See
the section Charging a Battery before attempting to recharge
a battery.
WARNING
Overloaded electrical cords can overheat, arc,
and burn resulting in death, bodily injury, and/or
property damage.
ONLY use cords rated for your loads.
Follow all safeties on electrical cords.
9
4-Wire Cord Set
240V
120V
120V
NEMA L14-20
W (Neutral)
X (Hot)
Y (Hot)
Ground (Green)
NOTICE
Receptacles may be marked with rating value greater than
generator output capacity.
NEVER attempt to power a device requiring more amperage
than generator or receptacle can supply.
DO NOT overload the generator. See Don’t Overload Generator.
3-Wire Cord Set
Neutral
120V
Hot
Ground (Green)
NEMA L5-30
10 BRIGGSandSTRATTON.COM
Ground Fault Protection
This unit is equipped with a Ground Fault Circuit Interrupter
(GFCI). This device meets applicable federal, state and local
codes.
The GFCI protects against electrical shock that may be
caused if your body becomes a path which electricity travels
to reach ground. This could happen if you touch a “Live”
appliance or wire, or are touching plumbing or other
materials that connect to the ground.
When protected by a GFCI, one may still feel a shock, but the
GFCI should cut current off quickly enough so that a person
in normal health should not suffer any serious electrical
injury.
Test GFCI Circuit Breaker
Test your GFCI circuit breaker every month, as follows:
1. While generator is running, push white “Test” button.
The circuit breaker should trip (handle will move to
approximate center position), which will disconnect
power to outlets.
2. If handle moves to center, reset circuit breaker by
firmly moving handle to “Off” (down) position, then to
On” (up) position.
During Generator Use
If circuit breaker trips during use, it usually indicates faulty
electrical equipment or cords. However, test the circuit
breaker as follows;
1. Disconnect loads, reset and test circuit breaker as
described earlier. Let generator run without any loads
for 1 minute.
2. If circuit breaker tests correctly, the electrical
equipment or extension cords may be faulty. Replace
faulty electrical equipment and cords before further
use.
CAUTION
If circuit breaker does not trip:
DO NOT use generator.
Call a Briggs & Stratton Power Products service center.
WARNING
Generator produces hazardous voltage/current.
The GFCI will not protect you against the following situations:
-Line-to-line shocks;
-Current overloads or line-to-line short circuits.
The fuse or circuit breaker at the control panel must provide
such protection.
CAUTION
If circuit breaker does not reset properly:
DO NOT use generator.
Call a Briggs & Stratton Power Products service center.
CAUTION
If circuit breaker trips in the 1 minute period:
DO NOT use generator.
Call a Briggs & Stratton Power Products service center.
CAUTION
If circuit breaker tests correctly:
Have qualified personnel check all electrical equipment and
cords for any defects.
Replace electrical equipment and cords or take to a qualified
repair center.
WARNING
Generator produces hazardous voltage.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords which are worn,
frayed, bare or otherwise damaged.
DO NOT operate generator in the rain or wet weather.
DO NOT handle generator or electrical cords while standing in
water, while barefoot, or while hands or feet are wet.
DO NOT allow unqualified persons or children to operate or
service generator or electrical loads.
Operation
Starting the Engine
Disconnect all electrical loads from the generator. Use the
following start instructions:
1. Make sure unit is on a level surface.
IMPORTANT: Failure to start and operate the unit on a level
surface will cause the unit not to start or shut down during
operation.
2. Turn the fuel valve (A) to the “On” position.
3. Make sure idle control switch is in “Off” position.
4. Push engine rocker switch to run position (I).
5. Push choke lever to “Choke” position.
6. Grasp recoil handle and pull slowly until slight
resistance is felt. Then pull rapidly one time only to
start engine.
If engine starts, proceed to step 8.
If engine fails to start, proceed to step 7.
7. Move choke lever to “Half” choke position, and pull
recoil handle twice.
If engine fails to start, repeat steps 5 thru 6.
8. Slowly move choke lever to “Run” position. If engine
falters, move choke lever to “Half” choke position until
engine runs smoothly, and then to “Run” position.
IMPORTANT: If engine floods, move choke lever to “Run
position and crank until engine starts.
NOTE: If engine starts after 3 pulls but fails to run, or if unit
shuts down during operation, make sure unit is on a level
surface and check for proper oil level in crankcase. This unit
may be equipped with a low oil protection device. If so, oil
must be at proper level for engine to start.
A
11
WARNING
Starter cord kickback (rapid retraction) can result
in bodily injury. Kickback will pull hand and arm
toward engine faster than you can let go.
Broken bones, fractures, bruises, or sprains
could result.
When starting engine, pull cord slowly until resistance is felt and
then pull rapidly to avoid kickback.
NEVER start or stop engine with electrical devices plugged in
and turned on.
12 BRIGGSandSTRATTON.COM
Connecting Electrical Loads
1. Let engine stabilize and warm up for a few minutes
after starting.
2. Plug in and turn on the desired 120 and/or 240 Volt
AC, single phase, 60 Hz electrical loads.
NOTE:
DO NOT connect 240 Volt loads to the 120 Volt duplex
receptacles.
DO NOT connect 3-phase loads to the generator.
DO NOT connect 50 Hz loads to the generator.
DO NOT OVERLOAD THE GENERATOR. See Don’t
Overload Generator.
Stopping the Engine
1. Turn OFF and unplug all electrical loads from generator
panel receptacles. NEVER start or stop engine with
electrical devices plugged in and turned ON.
2. Move idle control switch to “Off” position.
3. Let engine run at no-load for several minutes to
stabilize internal temperatures of engine and generator.
4. Push engine rocker switch to stop position (O).
5. Move fuel valve to “Off” position.
Operating Automatic Idle Control
This feature is designed to greatly improve fuel economy.
When this switch is turned ON, the engine will only run at
its normal high governed engine speed when electrical loads
are connected. When electrical loads are removed, the
engine will run at a reduced speed.
With the switch off, the engine will run at the normal high
engine speed. Always have the switch off when starting and
stopping the engine.
Oil Pressure Shutdown
If engine oil pressure drops below a preset level, an oil
switch will stop the engine. Check oil level with dipstick.
If oil level is between ADD and FULL mark on dipstick:
1. DO NOT try to restart the engine.
2. Contact a Briggs & Stratton Authorized Dealer.
3. DO NOT operate engine until oil pressure is corrected.
If oil level is below ADD mark on dipstick:
1. Add oil to bring level to FULL mark.
2. Restart engine and if the engine stops again a low oil
pressure condition may still exist. DO NOT try to restart
the engine.
3. Contact a Briggs & Stratton Authorized Dealer.
4. DO NOT operate engine until oil pressure is corrected.
WARNING
Contact with muffler area can result in serious
burns.
Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.
DO NOT touch hot parts and AVOID hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 5 feet (1.5 m) of clearance on all sides of
generator including overhead.
Code of Federal Regulation (CFR) Title 36 Parks, Forests, and
Public Property require equipment powered by an internal
combustion engine to have a spark arrester, maintained in
effective working order, complying to USDA Forest service
standard 5100-1C or later revision. In the State of California a
spark arrester is required under section 4442 of the California
Public resources code. Other states may have similar laws.
NOTICE
Exceeding generators wattage/amperage capacity can
damage generator and/or electrical devices connected to it.
DO NOT exceed the generator’s wattage/amperage capacity. See
Don’t Overload Generator in the Operation section.
Start generator and let engine stabilize before connecting
electrical loads.
Connect electrical loads in OFF position, then turn ON for
operation.
Turn electrical loads OFF and disconnect from generator before
stopping generator.
WARNING
Backfire, fire or engine damage could occur.
DO NOT stop engine by moving choke control to “Choke
position.
13
Charging a Battery
Your generator has the capability of recharging a discharged
12 Volt automotive or utility style storage battery.
DO NOT use the unit to charge any 6 Volt batteries.
DO NOT use the unit to crank an engine having a
discharged battery.
To recharge 12 Volt batteries, proceed as follows:
1. Check fluid level in all battery cells. If necessary, add
ONLY distilled water to cover separators in battery
cells. DO NOT use tap water.
2. If battery is equipped with vent caps, make sure they
are installed and are tight.
3. If necessary, clean battery terminals.
4. Connect battery charge cable connector plug to panel
receptacle identified by the words “12V 10A D.C.”
5. Connect battery charge cable clamp with red handle to
the positive (+) battery terminal.
6. Connect battery charge cable clamp with black handle
to the negative (–) battery terminal.
7. Start engine. Let engine run while battery recharges.
8. When battery has charged, shut down engine.
NOTE: Use an automotive hydrometer to test battery state of
charge and condition. Follow the hydrometer manufacturer’s
instructions carefully. Generally, a battery is considered to be
at 100% state of charge when specific gravity of its fluid (as
measured by hydrometer) is 1.260 or higher.
Cold Weather Operation
Under certain weather conditions (temperatures below 40°F
[4°C] combined with high humidity), your generator may
experience icing of the carburetor and/or the crankcase
breather system. To reduce this problem, you need to
perform the following:
1. Make sure generator has clean, fresh fuel.
2. Open fuel valve (turn valve to open position).
3. Use SAE 5W-30 oil.
4. Check oil level daily or after every eight (8) hours of
operation.
5. Maintain generator following Maintenance Schedule in
Maintenance section.
6. Shelter unit from elements.
Creating a Temporary Shelter
1. In an emergency, use the original shipping carton.
2. Cut off top carton flaps and one long side of carton to
expose muffler side of unit. If required, tape up other
sides of carton to fit over generator as shown.
NOTE: If required, remove wheel kit to fit carton over
generator as shown.
3. Cut appropriate slots to access receptacles of unit.
4. Face exposed end away from wind and elements.
5. Locate generator as described in the section Generator
Location. Keep exhaust gas from entering a confined
area through windows, doors, ventilation intakes or
other openings.
Wind
Typical Generator
Shown
DANGER
Storage batteries give off explosive hydrogen
gas during recharging.
Hydrogen gas stays near battery for a long time
after battery has been charged.
Slightest spark will ignite hydrogen and cause
explosion.
You can be blinded or severely injured.
Battery electrolyte fluid contains acid and is
extremely caustic.
Contact with battery fluid will cause severe
chemical burns.
DO NOT allow any open flame, spark, heat, or lit cigarette during
and for several minutes after charging a battery.
Wear protective goggles, rubber apron, and rubber gloves.
14 BRIGGSandSTRATTON.COM
6. Start generator as described in the section Starting the
Engine, then place carton over generator. Keep at least
5 ft. (1.5 m) clearance on all sides of generator
including overhead with shelter in place.
7. Remove shelter when temperatures are above 40°F
[4°C].
8. Turn engine OFF and let cool two (2) minutes before
refueling. Let any spilled fuel evaporate before starting
engine.
Creating a Permanent Shelter
1. Build a structure that will enclose three sides and the
top of the generator, making sure muffler side of
generator is exposed.
NOTE: Structure should hold enough heat created by the
generator to prevent icing problem.
2. DO NOT enclose generator any more than shown.
NOTE: If a wheel kit is installed on the generator, enlarge
shelter accordingly.
3. Follow steps 3 through 8 as described previously in
Creating a Temporary Shelter.
WARNING
Running engine gives off carbon monoxide, an
odorless, colorless, poison gas.
Breathing carbon monoxide can cause headache,
fatigue, dizziness, vomiting, confusion, seizures,
nausea, fainting or death.
Operate generator ONLY outdoors.
Install a battery operated carbon monoxide alarm near the
bedrooms.
Keep exhaust gas from entering a confined area through
windows, doors, ventilation intakes, or other openings.
DO NOT start or run engine indoors or in an enclosed area,
(even if windows and doors are open), including the generator
compartment of a recreational vehicle (RV).
WARNING
Contact with muffler area can result in serious
burns.
Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.
DO NOT touch hot parts and AVOID hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 5 feet (1.5 m) of clearance on all sides of
generator including overhead.
Remove shelter when temperatures are above 40°F [4°C].
15
Don’t Overload Generator
Capacity
You must make sure your generator can supply enough
rated (running) and surge (starting) watts for the items you
will power at the same time. Follow these simple steps:
1. Select the items you will power at the same time.
2. Total the rated (running) watts of these items. This is
the amount of power your generator must produce to
keep your items running. See the table on the right.
3. Estimate how many surge (starting) watts you will need.
Surge wattage is the short burst of power needed to
start electric motor-driven tools or appliances such as a
circular saw or refrigerator. Because not all motors start
at the same time, total surge watts can be estimated by
adding only the item(s) with the highest additional surge
watts to the total rated watts from step 2.
Example:
Total Rated (Running) Watts = 3075
Highest Additional Surge Watts = 1800
Total Generator Output Required = 4875
Power Management
To prolong the life of your generator and attached devices, it
is important to take care when adding electrical loads to your
generator. There should be nothing connected to the
generator outlets before starting its engine. The correct and
safe way to manage generator power is to sequentially add
loads as follows:
1. With nothing connected to the generator, start the
engine as described in this manual.
2. Plug in and turn on the first load, preferably the largest
load you have.
3. Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly).
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
NEVER add more loads than the generator capacity. Take
special care to consider surge loads in generator capacity, as
described above.
* Wattages listed are approximate only. Check tool or
appliance for actual wattage.
Tool or Appliance Watts (Starting) Watts
Window Air
Conditioner
1200 1800
Refrigerator 800 1600
Deep Freezer 500 500
Television 500
Light (75 Watts) 75
3075 Total
Running Watts
1800 Highest
Surge Watts
Tool or Appliance
Rated*
(Running)
Watts
Additional
Surge (Starting)
Watts
Essentials
Light Bulb - 75 watt 75 -
Deep Freezer 500 500
Sump Pump 800 1200
Refrigerator/Freezer - 18 Cu. Ft. 800 1600
Water Well Pump - 1/3 HP 1000 2000
Heating/Cooling
Window AC - 10,000 BTU 1200 1800
Window Fan 300 600
Furnace Fan Blower - 1/2 HP 800 1300
Kitchen
Microwave Oven - 1000 Watt 1000 -
Coffee Maker 1500 -
Electric Stove - Single Element 1500 -
Hot Plate 2500 -
Family Room
DVD/CD Player 100 -
VCR 100 -
Stereo Receiver 450 -
Color Television - 27” 500 -
Personal Computer w/17” monitor 800 -
Other
Security System 180 -
AM/FM Clock Radio 300 -
Garage Door Opener - 1/2 HP 480 520
Electric Water Heater - 40 Gallon 4000 -
DIY/Job Site
Quartz Halogen Work Light 1000 -
Airless Sprayer - 1/3 HP 600 1200
Reciprocating Saw 960 960
Electric Drill - 1/2 HP 1000 1000
Circular Saw - 7 1/4” 1500 1500
Miter Saw - 10” 1800 1800
Table Planer - 6” 1800 1800
Table Saw/Radial Arm Saw - 10” 2000 2000
Air Compressor - 1-1/2 HP 2500 2500
16 BRIGGSandSTRATTON.COM
General Recommendations
Regular maintenance will improve the performance and
extend the life of the generator. See any authorized dealer for
service.
The generator’s warranty does not cover items that have
been subjected to operator abuse or negligence. To receive
full value from the warranty, the operator must maintain the
generator as instructed in this manual.
Some adjustments will need to be made periodically to
properly maintain your generator.
All service and adjustments should be made at least once
each season. Follow the requirements in the Maintenance
Schedule chart above.
NOTE: Once a year you should clean or replace the spark
plug and replace the air filter. A new spark plug and clean air
filter assure proper fuel-air mixture and help your engine run
better and last longer.
Emissions Control
Maintenance, replacement, or repair of the emissions control
devices and systems may be performed by any non-road
engine repair establishment or individual. See Emissions
Control System Warranty in the Warranties section.
Maintenance
Maintenance Schedule
Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in adverse
conditions noted below.
¹ Change oil after the first (5) operating hours and every 50 hours or every year, whichever occurs first, thereafter.
Change oil sooner when operating under dirty or dusty conditions.
² Replace more often under dirty or dusty conditions.
Maintenance Schedule - Fill in Dates as You Complete Regular Service
Maintenance Task
Service Intervals
Service Dates
Before
Each Use
Every 25 Hours
or Yearly
Every 50 Hours
or Yearly
Every 100 Hours
or Yearly
Clean debris
X
Check oil level
X
Change engine oil
X
1
Service air cleaner pre-filter
X
2
Service air cleaner paper filter
X
2
Service fuel filter
X
Service spark plug
X
Service spark arrester
X
Clean cooling system
X
2
Prepare for storage
If unit is to remain idle for longer than 30 days.
17
Generator Maintenance
Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive dust,
dirt, moisture, or any corrosive vapors. Cooling air slots in
the generator must not become clogged with snow, leaves,
or any other foreign material.
NOTE: DO NOT use water or other liquids to clean
generator. Liquids can enter engine fuel system, causing
poor performance and/or failure to occur. In addition, if
liquid enters generator through cooling air slots, some of the
liquid will be retained in voids and cracks of the rotor and
stator winding insulation. Liquid and dirt buildup on the
generator internal windings will eventually decrease the
insulation resistance of these windings.
Cleaning
Daily or before use, look around and underneath the
generator for signs of oil or fuel leaks. Clean accumulated
debris from inside and outside the generator. Keep the
linkage, spring and other engine controls clean. Keep the
area around and behind the muffler free from any
combustible debris. Inspect cooling air slots and openings
on generator. These openings must be kept clean and
unobstructed.
Engine parts should be kept clean to reduce the risk of
overheating and ignition of accumulated debris:
Use a damp cloth to wipe exterior surfaces clean.
Use a soft bristle brush to loosen caked on dirt or oil.
Use a vacuum cleaner to pick up loose dirt and debris.
Fuel Valve Maintenance
The fuel valve is equipped with a fuel sediment cup, screen,
retaining ring and o-ring that need to be cleaned every
100 hours or once a year (whichever occurs first).
1. Move fuel valve to “Off” position.
2. Remove sediment cup (A) from fuel valve. Remove
o-ring (B), retaining ring (C) and screen (D) from fuel
valve.
3. Wash sediment cup, o-ring, retaining ring, and screen
in a nonflammable solvent. Dry them thoroughly.
4. Place screen, retaining ring, and o-ring into fuel valve.
Install sediment cup and tighten securely.
5. Move fuel valve to “On” position, and check for leaks.
Replace o-ring if there is any leakage.
NOTICE
Improper treatment of generator can damage it and
shorten its life.
DO NOT expose generator to excessive moisture, dust, dirt, or
corrosive vapors.
DO NOT insert any objects through cooling slots.
A
B
C
D
18 BRIGGSandSTRATTON.COM
Engine Maintenance
Oil
Oil Recommendations
NOTE: Use a high quality detergent oil classified “For Service
SF, SG, SH, SJ” or higher. DO NOT use special additives.
1. Choose a viscosity according to the table below:
NOTE: Synthetic oil meeting ILSAC GF-2, API certification
mark and API service symbol with “SJ/CF ENERGY
CONSERVING” or higher, is an acceptable oil at all
temperatures. Use of synthetic oil does not alter required oil
change intervals.
SAE 30: 40°F and higher (5°C and higher) is good for all
purpose use above 40°F, use below 40°F will cause hard
starting.
10W-30: 0 to 100°F (-18 to 38°C) is better for varying
temperature conditions. This viscosity improves cold
weather starting, but may increase oil consumption above
80°F (27°C).
*Check oil level frequently at higher temperatures.
Synthetic 5W-30: -20 to 120°F (-30 to 40 °C) provides the
best protection at all temperatures as well as improved
starting with less oil consumption.
5W-30: 40°F and below (5°C and below) is recommended
for winter use and works best in cold conditions.
Checking Oil Level
Oil level should be checked prior to each use or at least
every 5 hours of operation. Keep oil level maintained.
1. Make sure generator is on a level surface.
2. Clean area around oil fill, remove oil cap/dipstick and
wipe dipstick with clean cloth. Replace and tighten
dipstick. Remove and and check oil level.
3. Verify oil is at “Full” mark (A) on dipstick. Replace and
tighten oil cap/dipstick.
Adding Engine Oil
1. Make sure generator is on a level surface.
2. Check oil level as described in Checking Oil Level.
3. If needed, slowly pour oil into oil fill opening to the
Full” mark on dipstick. DO NOT overfill.
4. Replace and tighten oil cap/dipstick.
WARNING
Unintentional sparking can result in fire or
electric shock.
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR
Disconnect the spark plug wire from the spark plug and place
the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
Use approved spark plug tester.
DO NOT check for spark with spark plug removed.
NOTICE
Overfilling with oil may cause the engine to not start, or
hard starting.
DO NOT overfill.
If over the FULL mark on dipstick, drain oil to reduce oil level to
FULL mark on dipstick.
A
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88

Simplicity 030342-00 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur