INSTALLATION INSTRUCTIONS
PD-82044
Fig.1
Mounting Plate Dimensions
Fig.4
Pink or Gray- Dim
Red - Fixture+
Black - Fixture-
Black - Hot
White - Neutral
Green - Ground
PREPARATION
DIMMING WIRING INFORMATION (Fig. 3)
Plastic Anchor
Wire Connector
GND Screw
Junction Box Screw Mounting Screw
Junction Box
Mounting Plate
Wood Screw
Wire Connector
Fixture’s Wire
2x 6” Rods
6x12” Rods
Driver
Swivel
Union Joint
Glass
(RPL-GLA-82024)
Base
F
Turn to down
11. Secure the xture to the mounting plate use the mounting screw (B).
12. Rotate the glass into the Base.
13. For slope ceiling applications, rotate swivel at the top of the stem to ensure luminaire is aiming down (Fig.4).
CONNECTING THE WIRES (Fig. 2)
MOUNTING THE FIXTURE (Fig. 1)
3. Remove the mounting screw (B) from the xture, take down the mounting plate.
4. Drill holes in the wall aligned with the key holes located in the mounting plate, insert the plastic anchor(E).
5. Secure the mounting plate to the junction box using standard junction box screws that comes with the
junction box. fasten it to the wall using wood screw(D).
Note: (i) using any other non-original-manufacturer provided junction box screw may result in safety issue;
(ii) The side of the mounting back plate marked “GND” must face out.
6. Choose the number of the rods suitable for your application. Thread the xture wire through the rods, union joint, swivel and canopy.
Connect the xture, rods, union joint and swivel. Make sure all are tightened.
Note: When connecting the union joint (F), rst attach it to the rod, then attach it to the swivel.
7. Connect the xture’s wires with driver’s output wires using wire connectors (B), Connect the driver’s input wires to junction box wires using
wire connectors (A) as shown in Fig. 2, making sure that all wire connectors are secured. If you outlet box has a green or bare copper ground
wire, connect the xture’s ground wire to it. Otherwise, connect the xture’s ground wire directly to the mounting plate using the GND screw
provided. After wires are connected, tuck them carefully inside the junction box.
1. Shut o the power at the circuit breaker and remove existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to
lose any small parts necessary for installation.
COMPLETING THE INSTALLATION (Fig. 1)
8. This xture features electronic low voltage (ELV or TRIAC ) or 0-10V dimming capabilities. See notes below for specic dimming wires information.
9. To utilize ELV or TRIAC dimming: use wires black (hot), white (neutral) and bare copper ground wire (ground).
10. To utilize 0-10V dimming: use wire purple (dim+), pink or gray (dim-), black (hot), white(neutral) and bare copper ground wire (ground).
NOTE: Make sure to connect 0-10V prior to power-up the xture in order to allow the 0-10V dimming to function properly.
Fig. 2 Wiring
Fig. 3
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
purple - Dim
Ø
48”
2w”
Ø
1w”
168”
10a”