Modern Forms WS-30118 Luzerne Mode d'emploi

Taper
Mode d'emploi
WARNING: All parts must be used as indicated in these instructions. This product is designed for use only with the supplied parts and/or
accessories designated for use by Modern Forms. Substitution of parts or accessories not designated for use with this product by Modern Forms
could result in personal injury or property damage, and will void the warranty. Contact an authorized dealer or the manufacturer if any parts are
damaged or missing.
ATTENTION: Toutes les pièces doivent être utilisées comme indiqué dans ces instructions. Ce produit est conçu pour être utilisé seulement avec
les pièces et/ou accessoires fournis pour être utilisés avec les produits Modern Forms. Remplacer des pièces ou accessoires non conçus pour ce
produit Modern Forms pourrait causer des dommages corporels ou matériels et pourrait également causer l’annulation de la garantie. Veuillez
contacter un revendeur autorisé ou le fabricant si des pièces manquent ou sont endommaes.
1
INSTALLATION INSTRUCTIONS
301 - LED Wall Sconce
WS-30118 / WS-30128
HARDWARE
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement progr
am. JANUARY, 2017
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
CAUTION: To prevent electrical shock, ensure electricity has been turned off at the circuit breaker before beginning.
Read all instructions before installing.
System is intended for installation by a licensed electrician in accordance with the National Electrical Code (NEC) and local regulations.
When handling the fixture, do not apply pressure to the LEDs. Hold the fixture by the base only.
Retain installation instructions for future maintenance reference.
MAINTENANCE NOTE: Coastal conditions may cause mineral and residue build-up on the fixture. We recommend that customers in coastal
areas clean all external surfaces of the fixture once every two weeks with a wet cloth.
MISE EN GARDE: Pour éviter tout choc électrique, assurez-vous que le disjoncteur soit mis hors tension avant de commencer.
Lisez toutes les instructions avant l’installation.
Le système doit être installé par un électricien licensié conformément au code national de l’électricité (NEC), et également aux
règlements locaux.
Lors de la manipulation du luminaire, n’appuyez pas sur les LED. Tenez-le uniquement par la base.
NOTE D’ENTRETIEN: Les conditions côtières peut causer une accumulation de minéraux et de résidue sur le luminaire. Nous recommendons
aux clients qui resident dans les zones côtières de nettoyer toutes les surfaces externes du luminaire une fois toutes les deux semaines avec
un chiffon humide.
A
A
A
B
A
C
A
D
A
E
A
F
A
G
A
H
A
I
A
J
Wire Connector
Qty: 3pcs+1 Extra
Mounting Screw
Qty:1 Extra Plastic Anchor
Qty: 2pcs+1 Extra
Knurling Nut
Qty: 2pcs+1 Extra
Wood Screw
Qty: 2pcs+1 Extra
Fixed Screw
Qty:1 Extra
Assembly Screw
Qty: 2pcs+1 Extra Cover
Qty:1pc Mounting Ring
Qty: 1pc Conversion Plate
Qty: 1pc
Aug. 2020
A
A
A
B
A
E
A
F
A
H
A
D
A
I
A
J
A
C
A
G
A
D
A
E
INSTALLATION INSTRUCTIONS
WS-30118 / WS-30128
301 – LED Wall Sconce
2
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement progr
am. JANUARY, 2017
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Fig.1
Fig.2
Mounting Screw
Fixed Screw
Fixed Plate
Decorative Ring
Cover
Magnet
Wire Connector
Wood Screw
Plastic Anchor
Junction Box Screw
Switch Box
Back Plate
Long Reeded Glass
(RPL-GLA-30118-01)
(RPL-GLA-30128-01)
Short Reeded Glass
(RPL-GLA-30118-02)
(RPL-GLA-30128-02)
Wood Screw
Assembly Screw
Plastic Anchor
Knurling Nut
Back Plate
Conversion Plate
Mounting Ring
Junction Box
Junction Box Screw
Aug. 2020
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig. 3 Wiring
INSTALLATION INSTRUCTIONS
WS-30118 / WS-30128
301 – LED Wall Sconce
3
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement progr
am. JANUARY, 2017
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
PREPARATION
INSTALLATION
1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.
2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
NOTE: (1) Glass may be inserted into the decorative ring before installing the fixture
onto the wall;
(2) Glass can be fine-tuned to make its axis parallelled to the lamp body.
3. Remove the mounting screw (B) from the fixture, then remove the back plate.
4. Drill holes in the wall aligned with the key-hole located in the back plate, insert the plastic anchor (D).
5. Secure the back plate to the switch box using the junction box screws. Fasten the back plate to wall using the wood screw (E).
The side of the mounting plate marked “GND” must face out.
6. Connect the fixture’s wires to junction box wires as shown in Fig. 3, making sure that all wire connectors (A) are secured. If your outlet box
has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the
back plate using the GND screw provided. After wires are connected, tuck them carefully inside the switch box.
7. Remove the fixed screw (C) from the decorative ring, then remove the fixed plate .
8. Insert the reeded glass into the decorative ring as shown in Fig.1, then secure the fixed plate to the decorative ring using fixed screw (C), put
the cover (G) onto the fixed plate.
MOUNT ON SWITCH BOX
3. Remove the mounting screw (B) from the fixture, then remove the back plate.
4. Fasten the knurling nut (H) on the back plate.
5. Drill holes in the wall aligned with the key-hole located in the back plate, insert the plastic anchor (D).
6. Secure the mounting ring (I) to the junction box using junction box screw. Ensure the two holes (spacing 2-3/4”) are vertical as shown in Fig. 2 .
7. Place the back plate and the coversion plate (J) onto the mounting ring (I). Align the two holes on the back plate with the slots on conversion plate
(J) and the holes on mounting ring (I), fasten with assembly screw (F).
8. Connect the fixture’s wires to junction box wires as shown in Fig. 3, making sure that all wire connectors (A) are secured. If your outlet box has a
green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back
plate using the GND screw provided. After wires are connected, tuck them carefully inside the junction box.
9. Remove the fixed screw (C) from the decorative ring, then remove the fixed plate .
10. Insert the reeded glass into the decorative ring as shown in Fig.1, then secure the
fixed plate to the decorative ring using fixed screw (C), put the cover (G) onto the
fixed plate.
MOUNT ON JUNCTION BOX
(Fig. 1)
(Fig. 2)
Mounting Ring Dimensions
Back Plate Dimensions
4”
4”
1 3/4” 1 3/8”
WS-30118: 13”
WS-30128: 23 1/4”
WS-30118: 8 3/4”
WS-30128: 14 1/4”
3 1/4”
1 3/8”
1 5/8”
Aug. 2020
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JAN 2023 G0
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
INSTALLATION INSTRUCTION
Trimless Junction Box Cover
MKCP-3040-WT
OVERALL COMPONENT DIMENSIONS
CAUTION: TO PREVENT ELECTRICAL SHOCK, ENSURE ELECTRICITY HAS BEEN TURNED OFF AT THE CIRCUIT BREAKER BEFORE
BEGINNING.
-Read all instructions before installing.
-System is intended for installation by a licensed electrician in accordance with the National Electrical Code (NEC) and local regulations.
-When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
-Retain installation instructions for future maintenance reference.
WARNING: All parts must be used as indicated in these instructions. This product is designed for use only with the supplied parts and/or
accessories designated for use by Modern Forms. Substitution of parts or accessories not designated for use with this product by Modern Forms
could result in personal injury or property damage, and will void the warranty. Contact an authorized dealer or the manufacturer if any parts are
damaged or missing.
MISE EN GARDE: POUR ÉVITER TOUT CHOC ÉLECTRIQUE, ASSUREZVOUS QUE LE DISJONCTEUR SOIT MIS HORS TENSION AVANT DE
COMMENCER.
-Lisez toutes les instructions avant l’installation.
-Le système doit être installé par un électricien licensié conformément au code national de l’électricité (NEC), et également aux règlements
locaux.
-Lors de la manipulation du luminaire, n’appuyez pas sur les LED. Tenez-le uniquement par la base.
ATTENTION: Toutes les pièces doivent être utilisées comme indiqué dans ces instructions. Ce produit est conçu pour être utilisé seulement avec
les pièces et/ou accessoires fournis pour être utilisés avec les produits Modern Forms. Remplacer des pièces ou accessoires non conçus pour ce
produit Modern Forms pourrait causer des dommages corporels ou matériels et pourrait également causer l’annulation de la garantie. Veuillez
contacter un revendeur autorisé ou le fabricant si des pièces manquent ou sont endommagées.
COMPONENT OVERVIEW
The trimless junction box cover is intended for installation to NEC approved 4” square junction boxes recessed in drywall and ush with the
support structure. It may be covered with spackle and/or plaster to conceal junction box visibility. It is to be connected to compatible Modern
Forms xtures. Refer to specications sheets for more information.
2"
#8
TYP
HARDWARE
Wire Connector
Qty: 3 (+1 Extra)
½” Plastic Spacer
Qty: 2
⁄”-40 x 1⁄” Long
Mounting Screw
Qty: 2 (+1 Extra)
¾” Plastic Spacer
Qty: 2
A
D
B
E
#8-32 x ¾” Long
Junction Box Screw
Qty: 2 (+1 Extra)
1” Plastic Spacer
Qty: 2
C
F
NOTE: This accessory is supplied with an optional mounting C-ring for
xture connection via ⁄” K.O. hole. This component may be omitted
from the installation if mounting xtures using #8 screw holes.
2Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JAN 2023 G0
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
INSTALLATION INSTRUCTION
Trimless Junction Box Cover
MKCP-3040-WT
FIG. 1
FIG. 2
FIG. 4
TRIMLESS JUNCTION BOX COVER INSTALLATION:
The trimless junction box cover is compatible with NEC approved
4” square junction boxes recessed in drywall and ush with the
support structure.
1. Install compatible junction box (by others) to the framing
structure. Ensure the junction box is ush with the base or front
of framing structure (See FIG. 1).
2. Install the mounting plate to the junction box (See FIG. 2).
Ensure the spacer alignment base is facing outward.
FIG. 3
105mm
105mm
FIG. 5 FIG. 6
3. Determine the drywall thickness and select the appropriate
spacer to install between the mounting plate and the trimless
junction box cover (See FIG. 3).
NOTE: Only 1 matching pair of spacers are to be used per
installation.
4. Using the mounting screws provided, attach the trimless
junction box cover to the mounting plate (See FIG. 4).
5. Make a 4⁄” square cutout in drywall at the intended trimless
junction box cover location and proceed to install to framing
structure (See FIG. 5). Apply and nish spackle up to the center
hole of trimless junction box cover. Ensure #8 holes on the
cover are free of spackle. (See FIG. 6).
Mounting Plate
Plastic
Spacers
Trimless Junction Box Cover
Cover Mounting Screws
Ground Wire
Example: ½” Drywall (No Spacer)
⁄”½”
Spacer Alignment
Base
Spacer
Height
Drywall
Thickness
No Spacer ½”
½” ⁄”
¾” 1”
1” 1¼”
Junction Box
Screws
CB
D
E
F
3Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JAN 2023 G0
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
INSTALLATION INSTRUCTION
Trimless Junction Box Cover
MKCP-3040-WT
FIXTURE INSTALLATION TO JUNCTION BOX COVER:
The trimless junction box cover features two #8 holes which may be used to mount xtures:
1. Make appropriate splice connections. Wiring may be placed inside the xture or pushed into the junction box.
2. Using #8 mounting screws supplied with the lighting xture, attach the xtures to the #8 holes on the trimless junction box cover. Apply
xture cover or lensing (where applicable) to complete the installation. (See FIG. 7).
Fixture #8 Mounting Screws
FIG. 7
Wire Connector
A
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Modern Forms WS-30118 Luzerne Mode d'emploi

Taper
Mode d'emploi