Fhiaba FK30BI-LST Guide d'installation

Taper
Guide d'installation
Installation guide EN
Notice d’installation FR
Guía de instalación ES
www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222)www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222)
2
www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222)www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222)
1. IMPORTANT INSTRUCTIONS ........................................................................................................................................ 4
1.1 Important safety instructions ..............................................................................................................................................................4
1.2 Child safety ................................................................................................................................................................................................ 4
2. TECHNICAL REQUIREMENTS ....................................................................................................................................... 5
2.1 Appliance features and installation requirements ........................................................................................................................ 5
2.2 Installation cutout features: panel-ready columns .......................................................................................................................6
2.3 Installation cutout features: panel-ready ......................................................................................................................................... 8
2.4 Installation cutout features: cladded columns ...............................................................................................................................10
2.5 Installation cutout features: cladded .................................................................................................................................................12
2.6 Installation cutout features: X-Pro ......................................................................................................................................................14
2.6 Installation cutout features: X-Pro ......................................................................................................................................................16
2.7 Installation cutout features: X-Pro columns ....................................................................................................................................18
2.7 Installation cutout features: X-Pro columns ....................................................................................................................................20
3. PREPARING FOR THE INSTALLATION ......................................................................................................................... 22
3.1 Transport to installation site and unpacking ...................................................................................................................................22
3.2 Electrical and water connection .........................................................................................................................................................22
3.3 Energy: Alternatives and Home Automation ...................................................................................................................................23
3.4 Leveling ......................................................................................................................................................................................................24
4. CUTOUT DIMENSIONS .................................................................................................................................................. 25
4.1 Cutout dimension for combined installation (for all models except XPro) .............................................................................25
5. PANEL MOUNTING ........................................................................................................................................................ 26
5.1 Overlay door-panel layout .....................................................................................................................................................................26
5.2 Overlay panel layout for appliance with one bottom drawer ..................................................................................................... 28
5.3 Overlay panel layout for appliance with two bottom drawers ................................................................................................... 29
5.4 Overlay panel layout for appliance with glass door and one bottom drawer .......................................................................30
5.5 Overlay panel layout for appliance with glass door and two bottom drawers ..................................................................... 31
5.6 Overlay panel for column ...................................................................................................................................................................... 32
5.7 Overlay panel layout for column with glass door ..........................................................................................................................33
5.8 Panel dimensions: single bottom drawer ........................................................................................................................................34
5.9 Panels dimensions: two bottom drawers.........................................................................................................................................35
5.10 Panel dimensions column models ...................................................................................................................................................36
5.11 Mounting panels to the door .............................................................................................................................................................. 37
5.12 Mounting panels to the drawer .........................................................................................................................................................37
5.13 Optional 1/8’’ panel reveal for multiple-unit installation ..........................................................................................................38
6. INSTALLATION: BOTTOM COMPRESSOR MODELS ..................................................................................................... 39
6.1 Built-in installation of single appliance ............................................................................................................................................39
6.2 Built-in installation of two or more appliances .............................................................................................................................. 39
6.3 Maximum cabinet depth over panel-ready appliance with single door panel ...................................................................... 44
7. COMPLETING THE INSTALLATION ............................................................................................................................... 45
7.1 Anti-tipping safety assembly ...............................................................................................................................................................45
7.2 Ventilation ..................................................................................................................................................................................................46
7.3 Mounting the handles on cladded models ....................................................................................................................................... 47
7.4 Post-installation checklist ....................................................................................................................................................................47
7.5 Start-up ......................................................................................................................................................................................................47
3
INDEX EN
www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222)
4
1.1 Important safety instructions
Symbols used in the Guide:
Note
Tips for the correct use of the appliance
Important
Instructions for avoiding appliance damage
Warning
Instructions for preventing injury
1.2 Child safety
DANGER: Risk of child entrapment. Before disposing
of your old refrigerator, freezer or wine cellar:
> Remove the doors
> Leave the shelves in place, so that children may
not easily climb inside.
Dimensions in parentheses are in inches.
Weights in parentheses are in pounds.
Temperatures in parentheses are
in degrees Fahrenheit.
1. IMPORTANT INSTRUCTIONS
www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) 5
2.1 Appliance features and
installation requirements
Weight with
packaging 18”
up to 150 kg (331 lbs.)
24”
up to 170 kg (375 lbs.)
30”
up to 190 kg (419 lbs.)
36”
up to 200 kg (441 lbs.)
Voltage AC 110 - 120V 60Hz
Power supply
cable 90° Nema 5-15P
Dedicated circuit
breaker 15A
Potable water
supply pressure from 0.05 MPa to 0.5 MPa
(0.5 Bar - 5 Bar)
PSI measurement 7.25psi - 72.5psi
Water connection 3/4” NPT (1/4” elbow
adapter included)
Provided
installation
accessories
- Anti-tipping kit
- Lateral mounting clips
(10 pieces)
- Overlay panel mounting kit
- Water connection kit
- 4 mm (1/8”)
Additional
equipment needed - Phillips screwdriver
- wood drill
- 2.5 mm (1/8”) bit for wood
- 8 mm (3/8”) bit for walls
- 10 mm (3/8”) bit for walls
- 17 mm (11/16”) wrench
- 19 mm (3/4”) wrench
- 13 mm (1/2”) socket for
adjusting the rear leveling
legs
- 2.5 mm Allen wrench for
installing handles
Other provided
accessories - Cleaning kit
2. TECHNICAL REQUIREMENTS EN
www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222)
6
2. TECHNICAL REQUIREMENTS
2.2 Installation cutout features:
panel-ready columns
A Minimum cutout height
2134 mm (84”)
Cutout width
36” model: 914 mm (36”)
30” model: 762 mm (30”)
24” model: 610 mm (24”)
18” model: 457 mm (18”)
Minimum cutout depth
610 mm (24”) + panel thickness for flush installation
Area to be left clear for the anti-tipping brackets
127 mm (5”) for both right and left sides
B Appliance height
2120 mm (83 1/2”) + 25 mm (1”)
615 (24 ¼”)
565 (22 ¼” )
505 (19 ¾”)
A A
127 mm (5") 127 mm (5")
36": 914 mm (36”)
18": 457 mm (18”)
24": 610 mm (24”)
30": 762 mm (30”)
82 mm
(3 1/2")
min 2134
(84”)
82 mm
(3 1/2")
2120 (83 ½”)
+25 (1”)
233 (9
¼”
)
+ 25 (1”)
231 (9
⅛”
) +
25 (1”)
1808
(71 ¼” )
610 (24”)
560 (22)
500 (19 ¾”)
A A
127 mm (5") 127 mm (5")
36":914 (36”)
18": 457 (18”)
24": 610 (24”)
30": 762 (30”)
82 mm
(3 1/2")
min 2134
(84”)
82 mm
(3 1/2")
2120 (83 ½”)
+25 (1”)
233 (9
¼”
)
+ 25 (1”)
231 (9
⅛”
) +
25 (1”)
1808
(71 ¼” )
A
B
www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) 7
2. TECHNICAL REQUIREMENTS EN
90° hinges available
to be ordered as spare
part.
Door-Swing Clearance Minimum distance from
the wall (hinge side)
Width of appliance body.
Width of appliance with
mounting brackets installed
(eective width)
100°
36" model: 912 mm (35 ")
30" model: 760 mm (29 ")
24" model: 608 mm (23 ")
18" model: 455 mm (17 ")
36" model: 885 mm (34 ")
30" model: 735 mm (28 ")
24" model: 585 mm (23")
18" model: 435 mm (17 ")
36" model: 158 mm (6 ¼")
30" model: 132 mm (5 ¼" )
24" model: 108 mm (4 ¼")
18" model: 82 mm (3 ¼")
36" model: 1489 mm (58 ⅝")
30" model: 1338 mm (52 ⅝")
24" model: 1187 mm (46 ¾")
18" model: 1036 mm (40
¾
")
610 mm (24")
560 mm (22")
100°
36" model: 912 mm (35 ")
30" model: 760 mm (29 ")
24" model: 608 mm (23 ")
18" model: 455 mm (17 ")
36" model: 885 mm (34 ")
30" model: 735 mm (28 ")
24" model: 585 mm (23")
18" model: 435 mm (17 ")
36" model: 158 mm (6 ¼")
30" model: 132 mm (5 ¼" )
24" model: 108 mm (4 ¼")
18" model: 82 mm (3 ¼")
36" model: 1489 mm (58 ⅝")
30" model: 1338 mm (52 ⅝")
24" model: 1187 mm (46 ¾")
18" model: 1036 mm (40
¾
")
610 mm (24")
560 mm (22")
www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222)
8
2. TECHNICAL REQUIREMENTS
2.3 Installation cutout features:
panel-ready
A Minimum cutout height
2134 mm (84”)
Cutout width
36” model: 914 mm (36”)
30” model: 762 mm (30”)
24” model: 610 mm (24”)
Minimum cutout depth
610 mm (24”) + panel thickness for flush installation
Area to be left clear for the anti-tipping brackets
127 mm (5”) for both right and left sides
B Appliance height
2120 mm (83 1/2”) + 25 mm (1”)
C Appliance height
2120 mm (83 1/2”) + 25 mm (1”)
B
C
A A
140 (5 ½”) 140 (5 ½”)
36”: 914 mm (36”)
24”: 610 mm (24”)
30”: 762 mm (30”)
610 (24”)
560 (22”)
610 (24”)
560 (22”)
500 (19 ¾”)
500 (19 ¾”)
10 (⅜”)
100 (4”) 100 (4”)
min 2134
(84”)
2120 (83 ½”)
+25 (1”)
721 (28 ⅜”)
+25 (1”)
1293
(50 ⅞” )
20 (¾”)
474
(18 ⅝”)
248 (9 ¾”)
+ 25 (1”)
231 (9 ⅛”)
+ 25 (1”)
2120 (83 ½”)
+25 (1”)
846 (33 ¼”)
+25 (1”)
1168
(46”)
20 (¾”)
330 (13”)
259 (10 1/4”)
248 (9 ¾”)
+ 25 (1”)
231 (9 ⅛”)
+ 25 (1”)
A
www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) 9
2. TECHNICAL REQUIREMENTS EN
90° door swing available
using part 90STOP
Door-Swing Clearance Minimum distance from
the wall (hinge side)
Width of appliance body.
Width of appliance with
mounting brackets installed
(eective width)
100°
36” model: 912 mm (35 ")
30” model: 760 mm (29 ")
24” model: 608 mm (23 ")
36” model: 885 mm (34 ")
30” model: 735 mm (28 ")
24” model: 585 mm (23")
10 (⅜”)
36” model: 160 mm (6 ¼”)
30” model: 125 mm (5”)
24” model: 90 mm (3 ½”)
36” model: 1489 mm (58 ⅝”
)
30” model: 1338 mm (52 ⅝”
)
24” model: 1187 mm (46 ¾”)
992 (39”)
610 (24”)
560 (22”)
100°
36” model: 912 mm (35 ")
30” model: 760 mm (29 ")
24” model: 608 mm (23 ")
36” model: 885 mm (34 ")
30” model: 735 mm (28 ")
24” model: 585 mm (23")
10 (⅜”)
36” model: 160 mm (6 ¼”)
30” model: 125 mm (5”)
24” model: 90 mm (3 ½”)
36” model: 1489 mm (58 ⅝”)
30” model: 1338 mm (52 ⅝”)
24” model: 1187 mm (46 ¾”)
992 (39”)
610 (24”)
560 (22”)
www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222)
10
2. TECHNICAL REQUIREMENTS
2.4 Installation cutout features:
cladded columns
A Minimum cutout height
2134 mm (84”)
Cutout width
36” model: 914 mm (36”)
30” model: 762 mm (30”)
24” model: 610 mm (24”)
18” model: 457 mm (18”)
Minimum cutout depth (for flush installation)
630 mm (24 3/4 ”)
Area to be left clear for the anti-tipping brackets
127 mm (5”) for both right and left sides
B Appliance height
2120 mm (83 1/2”) + 25 mm (1”)
233 (9
¼”
)
+ 25 (1”)
A A
127 mm (5") 127 mm (5")
36":914 mm (36”)
18": 457 mm (18”)
24": 610 mm (24”)
30": 762 mm (30”)
615 (24 ¼”)
565 (22 ¼” )
231 (9
⅛”
) +
25 (1”)
505 (19 ¾”)
82 mm
(3 1/2")
82 mm
(3 1/2")
2120 (83 ½”)
+25 (1”)
min 2134
(84”)
1808
(71 ¼” )
A
B
A A
E W E W
140 (5 ½”) 140 (5 ½”)
100 (4”) 100 (4”)
KS899: 900 (35 ½”)
KS599: 600 (23 ¾”)
KS749: 750 (29 ⅝”)
620 (24 ”)
558 (22)
720 (28 ⅜)
KS449: 450 (17 ¾”)
2120 (83 ½”)
+25 (1”)
2024 (79 ¾”)
2120 (83 ½”)
+25 (1”)
96 (3 ¾”) + 25(1”)
www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) 11
2. TECHNICAL REQUIREMENTS EN
90° door swing available
using part 90STOP
Door-Swing Clearance
Width of appliance body.
Width of cladded door
Width of appliance with
mounting brackets installed
(eective width)
Minimum distance from
the wall (hinge side)
100°
36" model: 1487 mm (58 ½”)
30" model: 1336 mm (52 ⅝”)
24" model: 1185 mm (46 ⅝”)
18" model: 1034 mm (40 ¾’’)
36":
908 mm (35 ¾")
30":
756 mm (29 ¾")
24":
603 mm (23 ¾")
18": 451 mm (17
¾
")
36" model: 139 mm (5 ½”)
30" model: 103 mm (4 ⅛”)
24" model: 89 mm (3 ½”)
18" model: 63 mm (2 ½”)
620 (24 ”)
558 (22”)
68 (2 ¾”)
36" model: 885 mm (34 ")
30" model: 735 mm (28 ")
24" model: 585 mm (23")
18" model: 435 mm (17 ")
36" model: 912 mm (35 ")
30" model: 760 mm (29 ")
24" model: 608 mm (23 ")
18" model: 455 mm (17 ")
100°
36" model: 1487 mm (58 ½”)
36" model: 139 mm (5 ½”)
30" model: 103 mm (4 ⅛”)
24" model: 89 mm (3 ½”)
18" model: 63 mm (2 ½”)
www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222)
12
2. TECHNICAL REQUIREMENTS
2.5 Installation cutout features:
cladded
A Minimum cutout height
2134 mm (84”)
Minimum cutout width
36” model: 914 mm (36”)
30” model: 762 mm (30”)
24” model: 610 mm (24”)
Minimum cutout depth
635 mm (25 ”)
Area to be left clear for the anti-tipping brackets
127 mm (5”) for both right and left sides
B Appliance height
2120 mm (83 1/2”) + 25 mm (1”)
B
A
A A
140 (5 ½”) 140 (5 ½”)
36”: 914 mm (36”)
30”: 762 mm (30”)
24”: 610 mm (24”)
558 (22”)
735 (29)45 (1 ¾”)
9 ( ⅜”)
96 (3 ¾”)
615 (24 ¼”)
100 (4”) 100 (4”)
min 2134
(84”)
2120 (83 ½”)
+25 (1”)
732 (28 ⅞”)
+25 (1”)
1378
(54 ¼”)
637
(25 ⁄”)
www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) 13
2. TECHNICAL REQUIREMENTS EN
90° hinges available
to be ordered as spare
part.
Door-Swing Clearance Minimum distance from
the wall (hinge side)
Width of appliance body.
Width of cladded door
100°
10 (⅜”)
68 (2 ¾”)
36": 230 (9”)
30": 195 (7 ¾”
)
24": 160 (6 ¼”)
36":
1470 (57 ⅞”)
30": 1320 (52”)
24": 1170 (46”)
1016 (40”)
615 (24 ¼”)
558 (22”)
52 (2”)
36” model: 912 mm (35 ")
30” model: 760 mm (29 ")
24” model: 608 mm (23 ")
36” model: 885 mm (34 ")
30” model: 735 mm (28 ")
24” model: 585 mm (23")
100°
10 (⅜”)
68 (2 ¾”)
36": 230 (9”)
30": 195 (7 ¾”)
24": 160 (6 ¼”)
36": 1470 (57 ⅞”)
30": 1320 (52”)
24": 1170 (46”)
1016 (40”)
615 (24 ¼”)
558 (22”)
52 (2”)
36” model: 912 mm (35 ")
30” model: 760 mm (29 ")
24” model: 608 mm (23 ")
36” model: 885 mm (34 ")
30” model: 735 mm (28 ")
24” model: 585 mm (23")
www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222)
14
2. TECHNICAL REQUIREMENTS
2.6 Installation cutout features:
X-Pro
(North American standard cutout width)
A Minimum cutout height
2134 mm (84”)
Minimum cutout width
36” model: 914 mm (36”)
30” model: 762 mm (30”)
24” model: 610 mm (24”)
Depth with door
635 mm (25 ”)
Area to be left clear for the anti-tipping brackets
127 mm (5”) for both right and left sides
B Appliance height
2120 mm (83 1/2”) + 25 mm (1”)
B
A
When installing
our top
compressor
models in a
standard NA
cut out it is
recommended to
use the J-profile
trim kit to close
the lateral gap
of the appliance,
alternatively use
the standard
plastic mounting
clips when
installing unit
into Euro width
cabinet. (Shown
on next page)
Installing in the
unit in a standard
North American
“cutout” without
the J-profile trim
kit, will result
in a larger gap
along the cabinet
opening.
A A
140 (5 ½”) 140 (5 ½”)
36”: 914 mm (36”)
24”: 610 mm (24”)
30”: 762 mm (30”)
560 (22”)
635 (25”)
693 (27 ¼”)
195 (7 ⅝”)
8 (⅜”)
8 (⅜”)
97 (3 ⅞”)
+ 25 (1”)
100 (4”) 100 (4”)
min 2134
(84”)
2120 (83 ½”)
+25 (1”)
613 (24 ⅛”)
+25 (1”)
1296
(50”)
516
(20 ⅜”)
A A
140 (5 ½”) 140 (5 ½”)
36”: 914 mm (36”)
24”: 610 mm (24”)
30”: 762 mm (30”)
560 (22”)
635 (25”)
693 (27 ¼”)
195 (7 ⅝”)
8 (⅜”)
8 (⅜”)
97 (3 ⅞”)
+ 25 (1”)
100 (4”) 100 (4”)
min 2134
(84”)
2120 (83 ½”)
+25 (1”)
613 (24 ⅛”)
+25 (1”)
1296
(50”)
516
(20 ⅜”)
www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) 15
2. TECHNICAL REQUIREMENTS EN
Door-Swing Clearance Minimum distance from
the wall (hinge side)
Width of cutout/opening
Width of cladded door
Width of appliance with J-
profile installed (eective
width)
36” model: 935 mm (36 ¾”)
30” model: 785 mm (30 ⅞”)
24” model: 635 mm (25”)
36”:880mm (34 ⅝”)
30”:730mm (28 ¾”)
24”:580mm (22 ⅞”)
100°
36" model: 230 mm (9”)
30" model: 195 mm (7 ¾”)
24" model: 160 mm (6 ¼”)
36" model: 1470 mm (57 ⅞”)
30" model: 1320 mm (52”)
24" model: 1170 mm (46”)
1016 mm (40”)
635 mm (25”)
560 mm (22”)
75 mm (3”)
36” model: 914 mm (36”)
30” model: 762 mm (30”)
24” model: 610 mm (24”)
58 mm (2 ¼”)
24: 610 (24”)
18: 457 (18”)
30: 762 (30”)
36: 914 (36”)
36” model: 935 mm (36 ¾”)
30” model: 785 mm (30 ⅞”)
24” model: 635 mm (25”)
36”:880mm (34 ⅝”)
30”:730mm (28 ¾”)
24”:580mm (22 ⅞”)
100°
36" model: 230 mm (9”)
30" model: 195 mm (7 ¾”)
24" model: 160 mm (6 ¼”)
36" model: 1470 mm (57 ⅞”)
30" model: 1320 mm (52”)
24" model: 1170 mm (46”)
1016 mm (40”)
635 mm (25”)
560 mm (22”)
75 mm (3”)
36” model: 914 mm (36”)
30” model: 762 mm (30”)
24” model: 610 mm (24”)
58 mm (2 ¼”)
24: 610 (24”)
18: 457 (18”)
30: 762 (30”)
36: 914 (36”)
J-profile
code FXJTRIMSS
19 (
¾
)
7 (
¼
)
7 (
¼
)
25 (
1
)
60 (2
)
131 (5
)
Due to the design of this model (Euro width),
the J-Profile trims serve a dual purpose
in terms of improving the aesthetics when
installing into an existing standard North
American width cutout by increasing the
effective width of the model overlapping the
side gables and improving the transition for
a proud (not flush) installation, as this model
is also slightly deeper at 25” than a standard
cutout cabinet. (Shown on next page)
www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222)
16
2.6 Installation cutout features:
X-Pro
(European standard cutout width)
A Minimum cutout height
2134 mm (84”)
Minimum cutout width
36” model: 900 mm (35 1/2”)
30” model: 750 mm (29 5/8”)
24” model: 600 mm (23 3/4”)
Depth with door
635 mm (25 ”)
Area to be left clear for the anti-tipping brackets
127 mm (5”) for both right and left sides
B Appliance height
2120 mm (83 1/2”) + 25 mm (1”)
2. TECHNICAL REQUIREMENTS
B
A
A A
140 (5 ½”) 140 (5 ½”)
36”: 900 mm (35 ½”)
24”: 600 mm (23 ¾”)
30”: 750 mm (29 ⅝”)
560 (22”)
635 (25”)
693 (27 ¼”)
195 (7 ⅝”)
8 (⅜”)
8 (⅜”)
97 (3 ⅞”)
+ 25 (1”)
100 (4”) 100 (4”)
min 2134
(84”)
2120 (83 ½”)
+25 (1”)
613 (24 ⅛”)
+25 (1”)
1296
(50”)
516
(20 ⅜”)
A A
140 (5 ½”) 140 (5 ½”)
36”: 900 mm (35 ½”)
24”: 600 mm (23 ¾”)
30”: 750 mm (29 ⅝”)
560 (22”)
635 (25”)
693 (27 ¼”)
195 (7 ⅝”)
8 (⅜”)
8 (⅜”)
97 (3 ⅞”)
+ 25 (1”)
100 (4”) 100 (4”)
min 2134
(84”)
2120 (83 ½”)
+25 (1”)
613 (24 ⅛”)
+25 (1”)
1296
(50”)
516
(20 ⅜”)
When installing
our top
compressor
models in a new
construction, it is
recommended to
use the European
“cutout”
dimensions
to achieve a
minimal gap on
the lateral sides
and avoid the
need to use the
J-profile trim kit.
Installing in the
unit in a standard
North American
“cutout” without
the J-profile trim
kit, will result
in a larger gap
along the cabinet
opening.
www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) 17
EN
If the units are to be installed inside
a cutout or within an enclosed
structure, it is necessary to install
a ventilation shaft at the back of the
cutout to assure proper ventilation at
the back of the unit.
Cross-sectional chimney ventilation
area should equal 200 cm² (31in²).
Door-Swing Clearance Minimum distance from
the wall (hinge side)
Width of appliance body.
Width of cladded door
Width of appliance with
mounting brackets installed
(eective width)
2. TECHNICAL REQUIREMENTS
36
"
model: 898 mm (36 ”)
30
"
model: 748 mm (29 ½”)
24
"
model: 588 mm (23 ”)
36
":
880mm(34 ”)
30
":
730mm(28 ¾”)
24
":
580mm(22 ”)
100°
36" model: 230 mm (9”)
30" model: 195 mm (7 ¾”)
24" model: 160 mm (6 ¼”)
36" model: 1470 mm (57 ⅞”
)
30" model: 1320 mm (52”)
24" model: 1170 mm (46”)
1016 (40”)
635 mm (25”)
560 mm (22”)
75 mm (3”)
10 mm (⅜”)
58 mm (2 ¼”)
36" model: 885 mm (34 ")
30" model: 735 mm (28 ")
24" model: 585 mm (23")
36
"
model: 898 mm (36 ”)
30
"
model: 748 mm (29 ½”)
24
"
model: 588 mm (23 ”)
36
":
880mm(34 ”)
30
":
730mm(28 ¾”)
24
":
580mm(22 ”)
100°
36" model: 230 mm (9”)
30" model: 195 mm (7 ¾”)
24" model: 160 mm (6 ¼”)
36" model: 1470 mm (57 ⅞”)
30" model: 1320 mm (52”)
24" model: 1170 mm (46”)
1016 (40”)
635 mm (25”)
560 mm (22”)
75 mm (3”)
10 mm (⅜”)
58 mm (2 ¼”)
36" model: 885 mm (34 ")
30" model: 735 mm (28 ")
24" model: 585 mm (23")
www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222)
18
2.7 Installation cutout features:
X-Pro columns
(North American standard cutout width)
A Minimum cutout height
2134 mm (84”)
Cutout width
36” model: 914 mm (36”)
30” model: 762 mm (30”)
24” model: 610 mm (24”)
18” model: 457 mm (18”)
Depth with door
635 mm (25”)
Area to be left clear for the anti-tipping brackets
127 mm (5”) for both right and left sides
B Appliance height
2120 mm (83 1/2”) + 25 mm (1”)
Requires
J-profile trim
kit to finish the
large openings/
gaps around the
appliance or use
the standard
plastic mounting
clips for fitting
into Euro width
cabinet.
2. TECHNICAL REQUIREMENTS
B
A
A A
140 (5 ½”) 140 (5 ½”)
36”: 914 mm (36”)
24”: 610 mm (24”)
30”: 762 mm (30”)
560 (22”)
635 (25”)
693 (27 ¼”)
18”: 457 mm (18”)
100 (4”) 100 (4”)
min 2134
(84”)
2120 (83 ½”)
+25 (1”)
8 (⅜”)
195 (7 ⅝”)
1820
(71 ⅝”)
97 (3 ⅞”)
+ 25 (1”)
www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) 19
EN
Door-Swing Clearance
If the units are to be installed inside
a cabinet or within an enclosed
structure, it is necessary to install
a ventilation shaft at the back of the
cutout to assure proper ventilation at
the back of the unit. Cross-sectional
chimney ventilation
area should equal 200 cm² (31 in²).
Minimum distance from
the wall (hinge side)
Width of cutout/opening
Width of cladded door
Width of appliance with J-
profile installed (eective
width)
2. TECHNICAL REQUIREMENTS
100°
36”: 230 (9”)
30”: 195 (7 ¾”)
24”: 160 (6 ¼”)
18”: 125 (4 ⅞”)
XS899: 1475 (58”)
XS749: 1325 (52 ⅛”)
XS599: 1175 (46 ¼”)
XS449: 1025 (40 ⅜”)
90°
XS899: 230 (9”)
XS749: 195 (7 ¾”)
XS599: 160 (6 ¼”)
XS449: 125 (4 ⅞”)
75 (3”)
25 (1”)
90°
36”: 1480 (58 ¼”)
30”: 1330 (52 ⅜”)
24”: 1180 (46 ½”)
18”: 1030 (40 ½”)
36”: 1480 (58 ¼”)
30”: 1330 (52 ⅜”)
24”: 1180 (46 ½”)
18”: 1030 (40 ½”)
640 mm (25 1/4”)
560 (22”)
XS899 / FP36: 899 (35 ”)
XS749 / FP30: 749 (29 ½”)
XS599 / FP24: 599 (23 ”)
635 (25”)
560 (22”)
75 (3”)
635 (25”)
560 (22”)
75 (3”)
10 (⅜”)
58 (2 ¼”) 58 (2 ¼”)
10 (⅜”)
36" model: 898 mm (35 ")
30" model: 748 mm (29 ½")
24" model: 598 mm (23 ")
18" model: 448 mm (17 ")
36”:880mm (34 ⅝”)
30”:730mm (28 ¾”)
24”:580mm (22 ⅞”)
18”:430mm (18 ⅞”)
36" model: 885 mm (34 ")
30" model: 735 mm (28 ")
24" model: 585 mm (23")
18" model: 435 mm (17 ")
100°
36”: 230 (9”)
30”: 195 (7 ¾”)
24”: 160 (6 ¼”)
18”: 125 (4 ⅞”)
XS899: 1475 (58”)
XS749: 1325 (52 ⅛”)
XS599: 1175 (46 ¼”)
XS449: 1025 (40 ⅜”)
90°
XS899: 230 (9”)
XS749: 195 (7 ¾”)
XS599: 160 (6 ¼”)
XS449: 125 (4 ⅞”)
75 (3”)
25 (1”)
90°
36”: 1480 (58 ¼”)
30”: 1330 (52 ⅜”)
24”: 1180 (46 ½”)
18”: 1030 (40 ½”)
36”: 1480 (58 ¼”)
30”: 1330 (52 ⅜”)
24”: 1180 (46 ½”)
18”: 1030 (40 ½”)
640 mm (25 1/4”)
560 (22”)
635 (25”)
560 (22”)
75 (3”)
635 (25”)
560 (22”)
75 (3”)
10 (⅜”)
58 (2 ¼”)
58 (2 ¼”)
10 (⅜”)
36: 914 (36”)
30: 762 (30”)
24: 610 (24”)
18: 457 (18”)
36” model: 914 mm (36”)
30” model: 762 mm (30”)
24” model: 610 mm (24”)
36” model: 935 mm (36 ¾”)
30” model: 785 mm (30 ⅞”)
24” model: 635 mm (25”)
18” model: 485 mm (19 ⅛”)
36”:880mm (34 ⅝”)
30”:730mm (28 ¾”)
24”:580mm (22 ⅞”)
18”:430mm (18 ⅞”)
18” model: 458 mm (18”)
J profile
code FXJTRIMSS
19 (
¾
)
7 (
¼
)
7 (
¼
)
25 (
1
)
60 (2
)
131 (5
)
www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222)
20
2.7 Installation cutout features:
X-Pro columns
(European standard cutout width)
A Minimum cutout height
2134 mm (84”)
Cutout width
36” model: 900 mm (35 1/2”)
30” model: 750 mm (29 5/8”)
24” model: 600 mm (23 3/4”)
18” model: 450 mm (17 ¾”)
Depth with door
635 mm (25”)
Area to be left clear for the anti-tipping brackets
127 mm (5”) for both right and left sides
B Appliance height
2120 mm (83 1/2”) + 25 mm (1”)
2. TECHNICAL REQUIREMENTS
B
A
A A
140 (5 ½”) 140 (5 ½”)
560 (22”)
635 (25”)
693 (27 ¼”)
18”: 450 mm (17 ¾”)
100 (4”) 100 (4”)
min 2134
(84”)
2120 (83 ½”)
+25 (1”)
8 (⅜”)
195 (7 ⅝”)
1820
(71 ⅝”)
97 (3 ⅞”)
+ 25 (1”)
36”: 900 mm (35 ½”)
24”: 600 mm (23 ¾”)
30”: 750 mm (29 ⅝”)
A A
140 (5 ½”) 140 (5 ½”)
560 (22”)
635 (25”)
693 (27 ¼”)
18”: 450 mm (17 ¾”)
100 (4”) 100 (4”)
min 2134
(84”)
2120 (83 ½”)
+25 (1”)
8 (⅜”)
195 (7 ⅝”)
1820
(71 ⅝”)
97 (3 ⅞”)
+ 25 (1”)
36”: 900 mm (35 ½”)
24”: 600 mm (23 ¾”)
30”: 750 mm (29 ⅝”)
When installing
our top
compressor
models in a new
construction, it is
recommended to
use the European
“cutout”
dimensions
to achieve a
minimal gap on
the lateral sides
and avoid the
need to use the
J-profile trim kit.
Installing in the
unit in a standard
North American
“cutout” without
the J-profile trim
kit, will result
in a larger gap
along the cabinet
opening.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146

Fhiaba FK30BI-LST Guide d'installation

Taper
Guide d'installation