GE Appliances SIGN171 Guide d'installation

Taper
Guide d'installation
Tetra® Contour LS
LED Lighting System
Installation Guide
SIGN171 | GE2024-0587
24
Volt
RETROFIT SIGN CONVERSION LED KIT FOR USE ONLY IN
ACCORDANCE WITH KIT INSTRUCTIONS.
KIT IS COMPLETE ONLY WHEN ALL PARTS REQUIRED BY
THE INSTRUCTIONS ARE PRESENT.
TROUSSE DE CONVERSION À DEL POUR LA
MODERNISATION DES ENSEIGNES
À UTILISER CONFORMÉMENT AU GUIDE D’INSTALLATION.
Electrical Requirements
Acceptable to use in dry, damp and wet locations when
installed correctly.
The grounding and bonding of the LED Driver shall be done in
accordance with National Electric Code (NEC) Article 600.
Follow all National Electric Codes (NEC) and local codes.
These products are only suitable for connection to a circuit
from a Class 2 power source.
These products have not been evaluated for use when
connected to a power source that does not comply with
Class 2 voltage and energy limited supplies.
Save These Instructions
Use only in the manner intended by the manufacturer. If
you have any questions, contact the manufacturer.
WARNING / AVERTISSEMENT
RISK OF ELECTRIC SHOCK
Turn power o before inspection, installation or
removal.
Properly ground power supply enclosure.
RISK OF FIRE
Use only UL approved wire for input/output
connections. Minimum size 18 AWG (0.82mm2)
Follow all NEC and local codes.
Not to be submerged or used in a marine environment.
RISK OF FIRE OR ELECTRIC SHOCK
LED Retrot Kit installation requires knowledge of
sign electrical systems. If not qualied, do not attempt
installation. Contact a qualied electrician.
Install this kit only in host signs that have been identied
in the installation instructions and where the input rating
of the retrot kit does not exceed the input rating of the
sign.
Installation of this LED retrot kit may involve drilling or
punching of holes into the structure of the sign. Check
for enclosed wiring and components to avoid damage
to wiring and electrical parts.
Do not make or alter any open holes in an enclosure of
wiring or electrical components during kit installation.
RISQUES DE DÉCHARGES ÉLECTRIQUES
Coupez l’alimentation avant l’inspection, l’installation ou le
déplacement.
Assurez-vous de correctement mettre à terre l’alimentation électrique.
RISQUES D’INCENDIE
N’utilisez que des ls approuvés par UL pour les entrées/sorties de
connexion. Taille minimum 18 AWG (0.82mm2)
Respectez tous les codes NEC et codes locaux.
Ne pas submerger ou installer dans un environnement marin.
RISQUE D’INCENDIE OU DE CHOC ÉLECTRIQUE
L’installation de l’équipement de remplacement DEL exige Ia
connaissance des systèmes électriques pour enseignes. Si non qualié,
ne tentez pas d’installation. Veuillez contacter un électricien qualié.
Risque d’incendie ou de choc Électrique. Installez cet ensemble
seulement dans des enseignes hôtes qui ont été identiés dans les
instructions d’installation et dont la capacité d’entrée de l’ensemble
ne dépasse pas la capacité d’entrée de l’enseigne.
L’installation de cet équipement de remplacement DEL peut
impliquer le perçage ou le poinçonnage de trous dans la structure
du panneau Vériez le câblage et les composants inclus pour éviter
d’endommager le câblage et les composants électriques.
Ne pas faire ou modier les trous ouverts dans une enceinte de
câblage ou de composants électriques pendant l’installation de cet
équipement de remplacement DEL.
Outdoor installations require waterproong of wire connections. See instructions for details.
Avoid prolonged exposure to standing water or ice.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
GEXNLBL-1, GEXNLGL-1, GEXNLRD-1,
GEXNL65-1, GEXNL32-1
Prepare Electrical Wiring
Tetra® Contour LS Installation Guide
2
Components and Tools Required
UL approved 18 AWG (0.82mm2) supply wire
Tetra® End Caps
Weather boxes
Light Guide Mounting Clips
22 AWG (0.33mm2) tie-wire
#6, #8 or #10 (M2, M3 or M4) self drilling pan
headed screws
UL approved 22-14 AWG (0.33-2.08mm2) twist-on
wire connectors
Tetra® 24 Volt power supply
Tetra® Contour LS
Cordless drill
Tape measure
Wire stripper/cutter
Electrical grade silicone.
Examples of electrical grade silicone:
Momentive RTV 6700 Series Silicone Rubber Adhesive
Sealant
Momentive White Blanc RTV 162 Silicone Rubber Adhesive
Sealant-Electrical Grade
Dow Corning 3140 - Non-Corrosive Flowable (clear)
Dow Corning 3145 - Non-Corrosive Nonowable (clear or
gray)
Dow Corning RTV 748 Non-Corrosive Sealant-White
Cutting Resolution Table
Light Engine Color Color Cutting Resolution
GEXNLRD-1 Red 8 in. (203 mm)
GEXNLGL-1 Green 8 in. (203 mm)
GEXNLBL-1 Blue 8 in. (203 mm)
GEXNL65-1 White 8 in. (203 mm)
GEXNL32-1 Warm White 8 in. (203 mm)
Tc=80°C
(–)
(+)
8 feet (2.44m)
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005 du Canada.
1
1
13
13
14
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
10
10
11
11
12
12
9
NOTE: For planning the layout, measure the perimeter of the building and divide by 8 ft. (2.44m) to determine the required quantity
of Tetra Contour LS systems. See cutting resolution table on page 2 for guidelines when cutting any Tetra Contour LS sections. For
seamless designs, accessories are available for straight runs and 90 degree corners.
NOTE: Do not use more than one sux code for each respective application, as mixing sux codes may result in appearance variation.
Sux code can be found on the packaging label.
NOTE: Tetra Contour LS systems cannot be bent. Use only for straight runs.
Planning First
Tetra® Contour LS Installation Guide
3
METHOD A - Installing Tetra Contour LS - Straight Runs Only
For cut end, ll cap with electrical
grade silicone and push cap on the
end to seal. Clean excess silicone.
Secure light guide by twisting
tie-wire around the mounting clip
and light guide.
Insert wire connectors into weather
box. Fill with electrical grade
silicone and close box. Weather
box can be mounted using #8 (M3)
screws.
NOTE: Weather box is required for
all outdoor electrical connections.
Install one mounting clip at each
end and then a minimum of one
mounting clip every 18 inches
(457mm).
If required, using a sharp cutting
tool, cut wire loops between
sections (refer to the Cutting
Resolution Table on page 2).
Remove light engine from light
guide and cut light guide to
desired length.
Installation
Cut wiring
at top
Uncut
wiring at
bottom
For vertical or near vertical
installations, we recommend
designing such that any cut-end
termination of a Contour piece
resides at the top of the design.
Wires between light guide
segments can be folded behind
the light guide and attached with
clear zip ties.
NOTE: Zip ties should wrap around
outside light guide.
Plug together all adjacent Tetra
Contour LS sections and tuck wires
behind.
Continue attaching all the sections
to the remaining mounting clips,
leaving a 3/8 inch (10mm) gap
between sections to allow for
expansion or contraction.
Fill both end caps with
silicone and install
3/8 in. (10mm)
Light guide
Wire loops Light engine (back)
18 in. (457mm)
NOTE: Weather box
is required for all
outdoor electrical
connections.
Weather box can
be painted
CAUTION
Risk of damage. Must use
electrical grade silicone.
1
4
7
2
5
8
3
6
9
Tetra® Contour LS Installation Guide
4
For uncut end, fold wire over Tetra
Contour. Fill the end cap with
silicone and push cap on the end
to secure. Clean excess silicone.
Run a wire from the power supply
to a section of Tetra Contour LS.
NOTE: Power supply connection
must be contained in an acceptable
UL/NEMA enclosure.
NOTE: Power supply loading is
described in the power supply
installation instructions.
Electrical grade
silicone
Electrical
grade
silicone
Linear: At each gap between
sections, apply silicone on both
sides to secure light guide
connector. Snap on a light
guide connector.
Cut o the quick connector on
the Tetra Contour LS that you are
connecting to the power supply.
Corner: For all corners (planar,
inside, outside) insert rst light
guide all the way into the corner
connector. Then insert the second
light guide up to the rst one.
Using twist-on wire connectors,
connect the white wire with red
stripe (+) from the LED strip to the
red wire (+) of the power supply.
Connect the white wire (-) from the
LED strip to the black or blue wire
(-) of the power supply.
NOTE: Grounding and bonding
must be done in accordance with
National Electrical Code (Article
600). See power supply instructions.
Joining with Light Guide Connectors, Corners and Bends
Electrical Connections
Power
supply
To Tetra Contour LS
Red (+)
Black or blue (-)
White with
red stripe (+)
Red (+)
White (-)
Black or
blue (-)
To power supply
Weather box can be painted
Insert wire connectors into weather
box. Fill with electrical grade
silicone and close box.
Secure the weather box using a
#6 or #8 (M2 or M3) screw.
NOTE: When using twist-on
connectors, weather box is required
for all outdoor electrical connections.
NOTE: Do not use connectors pre-lled with silicone grease/mineral base protective grease or use silicone grease to seal connections.
NOTE: All electrical connections
should be suitably protected from
mechanical damage and the
environment. Seal all connections
in locations that may be exposed
to water with electrical grade RTV
silicone.
10
13
16
11
14
17
12
15
WARNING
Risk of electrical shock. Turn power OFF before inspection, installation or removal.
Tetra® Contour LS Installation Guide
5
METHOD B - Attaching Tetra Contour LS to Tetra Contour
Tetra Contour LS
+
++
Tetra Contour
White wire with
red stripe
Tetra Contour LS
Tetra Contour
Outside wires (+)
Center wire (-)
White wire with red stripe (+)
White wire (-)
Splice the white wire with red stripe (+) of Tetra Contour LS
to the two outside wires (+) of Tetra Contour and splice the
white wire (-) of Tetra Contour LS to the center wire (-) of
Tetra Contour. Insert wire connectors into weather box. Fill
with electrical grade silicone and close box.
Tetra Contour LS can be connected to formable Tetra
Contour for custom shapes. Separate wires and identify
conductors as positive (+) and negative (–). Strip ends
back 0.5 in. (13mm).
Weather box can be painted
Insert wire connectors into weather
box. Fill with electrical grade
silicone and close box.
Secure the weather box using a #6
or #8 (M2 or M3) screw.
NOTE: When using twist-on
connectors, weather box is
required for all outdoor electrical
connections.
NOTE: For assembling
accessories like
connectors and
corners, see Page 4.
1. (Existing Signs Only) Prior to installation, survey the site for information regarding power and accessibility inside and outside the
building. Ensure that the branch circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED
power supply, and have a current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes
(whichever is less).
2. (Existing Signs Only) Remove the existing lighting equipment to be replaced, such as neon tubing or uorescent tubes; and
associated transformers and ballasts. Care should be taken not to break the existing neon or uorescent tubes.
NOTE: Follow all federal and local regulations when disposing of neon tubing, uorescent tubes, transformers and ballasts.
3. (Existing Signs Only) If removal of the existing lighting equipment eliminates the disconnect switch, as required by applicable
local, state, or country electrical codes; a new disconnect switch must be installed.
4. (Existing Signs Only) Repair and seal any unused openings in the electrical enclosure. Openings greater than 12.7-mm (1/2-in)
diameter require a metal patch secured by screws or rivets and caulked with non-hardening caulk. Smaller openings may be sealed
with non-hardening caulk.
5. Using the layout guidelines above, determine required number of LED modules required to illuminate the sign.
6. A Tetra® 24VDC Class 2 Power Supply, as listed below, must be used with this retrot kit. Determine the number of Tetra® Class 2
Power Supplies required to power the number of LED modules required to illuminate the sign, so as not to overload the Tetra® Class
2 Power Supply chosen.
7. Follow method A or B to mount the Tetra Contour LS.
8. Connect the DC output of the power supply to the LED modules using the Electrical Connections instructions above.
9. Connect the power unit to the supply in accordance with the applicable local, state, and country electrical codes, and the instructions
found in the power supply installation guide.
10. If required, the disconnect switch shall be installed by qualied personnel, in accordance with applicable local, state, and country
electrical codes.
Retrot Instructions
1
3 4
2
Tetra® Contour LS Installation Guide
www.gecurrent.com
© 2021 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information provided is subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
SIGN171 (Rev 05/26/21) GE2024-0587
18 AWG/0.82 mm2
Supply Wire 16 AWG/1.31 mm2
Supply Wire 14 AWG/2.08 mm2
Supply Wire 12 AWG/3.31 mm2
Supply Wire
25W Power Supply 20 ft./6.1 m
80W Power Supply 20 ft./6.1 m 30 ft./9.1 m 50 ft./15.2 m 86 ft./26.1 m
100W Power Supply 20 ft./6.1 m 30 ft./9.1 m 50 ft./15.2 m 86 ft./26.1 m
180W Power Supply 20 ft./6.1 m 30 ft./9.1 m 50 ft./15.2 m 86 ft./26.1 m
Symptom Solution
All LEDs are OFF Check AC input connection and/or check circuit breaker
Check wire connection(s) at the Tetra Contour LS section and power supply for improper termination(s) or
short circuits. Properly terminate or replace the wire connection(s).
Check that connections are the white wire with red stripe (+) of the LED strip to the red wire (+) of the
power supply and the white wire (-) of the LED strip to the black or blue wire (-) of the power supply.
Some LEDs appear dim Ensure the overall length of the Tetra Contour LS does not exceed the maximum load.
Ensure the length of supply wire is equal to or below the recommended remote mounting distance.
Make sure that all LED light engines have the same sux code (sux code is located on the box label).
Some of the sections
are not illuminated Check wire connection(s) at the Tetra Contour LS section and power supply for improper termination(s) or
short circuits. Properly terminate or replace the wire connection(s).
Check that connections are the white wire with red stripe (+) of the LED strip to the red wire (+) of the power
supply and the white wire (-) of the LED strip to the black or blue wire (-) of the power supply.
SKU Rating
25W
Power Supply
Note: Load shall
not exceed 0.83A
80W
Power Supply
Note: Load shall
not exceed 3.3A
100W
Power Supply
Note: Load shall
not exceed 4A
180W
Power Supply
Note: Load shall not
exceed 3.8A per each
(of 2) output channels
300W
Power Supply
Note: Load shall not
exceed 4A per each
(of 3) output channels
GEXNLRD-1 24VDC, 1.30W/ft. (Strip)
1.53W/ft. (System) 16 ft. (4.88 m) 58 ft. (17.68 m) 69 ft. (21m)
65 ft. (19.81 m) per
output channel
130 ft. (39.62 m) per
power supply
69 ft. (21 m) per
output channel
207 ft. (63 m) per
power supply
GEXNLBL-1,
GEXNLGL-1 24VDC, 1.73W/ft. (Strip)
2.03W/ft. (System) 12 ft. (3.66 m) 44 ft. (13.41 m) 52 ft. (15.85 m)
48 ft. (14.63 m) per
output channel
96 ft. (29.26 m) per
power supply
52 ft. (15.8 m) per
output channel
156 ft. (47.5 m) per
power supply
GEXNL65-1,
GEXNL32-1 24VDC, 3.17W/ft. (Strip)
3.73W/ft. (System) 6 ft. (1.83 m) 24 ft. (7.3 m) 29 ft. (8.8 m)
27 ft. (8.2 m) per
output channel
54 ft. (16.4 m) per
power supply
29 ft. (8.8 m) per
output channel
87 ft. (26.5 m) per
power supply
Troubleshooting
This product is intended solely for the use of non-residential signage lighting and is not intended for use in any other applications.
Conforms to the following standards:
If you have any questions about these instructions or your specic application, please contact support at [email protected].
For the latest install guides for your product go to: www.gecurrent.com
Maximum Loading per Tetra® 24 VDC Power Supply