To disconnect your thermostat from the Wi-Fi router, press
the and buttons simultaneously for 10 seconds.
The symbol will disappear from the display.
To remove your thermostat from Neviweb, press "Delete" in the
thermostat's settings.
TECHNICAL SPECIFICATIONS
USER SETTINGS
DISCONNECT YOUR THERMOSTAT FROM THE WI-FI
ROUTER OR THE NEVIWEB APP
Operating voltage: 120/208/240/277Vac, 50/60 Hz
Maximum load:
1800 W @ 120 V / 15 A
3120 W @ 208 V / 15 A
3600 W @ 240 V / 15 A
4155 W @ 277 V / 15 A
Setpoint range: 5 °C to 30 °C (41 °F to 86 °F)
Display range: 0 °C to 50 °C (32 °F to 99 °F)
Resolution: ± 0.5 °C (± 1 °F)
Storage: -20 °C to 50 °C (-4 °F to 122 °F)
Operation: 0 °C to 50 °C (32 °F to 122 °F)
Protocol: Wi-Fi
Standard: IEEE 802.11 b/g/n
Frequency: 2.4 GHz
Controlling this HomeKit-enabled accessory automatically
and away from home requires a HomePod. Apple TV. or
iPad set up as a home hub. lt is recommended that you
update to the latest software and operating system.
Get the setpoint to its minimum and hold the button for 10 seconds to
access the menu.
Press the or button to change the setting,
Press the and buttons simultaneously to save and go to the next
parameter. Continue to press until the end of the list to exit the menu.
Ali of the thermostat's settings can be set through the Neviweb app.
However. if you have not created your account and wish to change
the temperature format, you need to:
Transmitter Module IC : 21098-ESPWROOM32 / FCC ID: 2AC7Z-ESPWROOM32
This device complies with Industry Canada license exempt RSS standard(s). Operation is subject to the
following two conditions:
(1) this device does not cause interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy, and if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to
try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.Increase the separation between the equipment and
receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected. Consult the dealer or an experienced radio/TV technician for help.
INSTALL YOUR THERMOSTAT
Unlock and lift the
thermostat cover.
Use the screws to secure the
thermostat to the electrical box.
Replace the cover and lock. Power up the thermostat.
Warnings
Before starting the installation of your new thermostat.
make sure that the breakers for your heating system are
off at the main electrical panel!
The installation of this thermostat must be performed
by a certified electrician and comply with the national
and local electrical codes and regulations.
Use the provided connectors
to connect the load/line wires
located on the back of the
thermostat.
12
345
Make sure to firmly tighten the
wire connectors for a secure
connection. A loose connection
can be a fire hazard.
3-year limited warranty
SINOPÉ TECHNOLOGIES INC. warrants the components of their products against
defects in material and workmanship for a 3 year period from the date of purchase,
under normal use and service, when proof of purchase of such is provided to the
manufacturer. This warranty does not cover any transportation costs that may be
incurred by the consumer. Nor does it cover a product subjected to misuse or
accidental damage. The obligation of SINOPÉ TECHNOLOGIES INC., under the
terms of this warranty, will be to supply a new unit and this releases the
manufacturer from paying the installation costs or other secondary charges linked
to replacing the unit or the components.
TH1500WF
Installation Guide
Smart Double
Pole Thermostat
For more information, visit our website:
660-0738-0006-A
Red (Line)
Red (Load)
Black (Load)
Black (Line)
SETTINGS WHICH CAN BE MODIFIED ON
THE DEVICE DIRECTLY
ADD YOUR THERMOSTAT TO
THE NEVIWEB APP
Tap the , then select "Add Device".
Select "Thermostats", then tap on your thermostat model:
TH1500WF.
2
1If you do not have an account yet,
download the Neviweb app for iOS or
Android to create an account and add
your device.
Follow the steps of
the Installation Wizard.
3
1) Load power
Reading of the load power connected to the thermostat, featured in watts.
Max
Load
Temp
Min
Temperature format
°C or °F (Default: °C)
Minimum setpoint
5 °C to 30 °C (Default: 5 °C)
Maximum setpoint
5 °C to 30 °C (Default: 30 °C)
Load power
0 W to 4155 W
4
Name Parameters & settings Display
3
2
1
Use of the Works with Apple badge means that an accessory has been designed to work
specifically with the technology identified in the badge and has been certified by the developer
to meet Apple performance standards. Apple is not responsible for the operation of this device
or its compliance with safety and regulatory standards.
HomeKit is a trademark of Apple Inc.
Neviweb® is a registered trademark of Sinopé Technologies Inc. in Canada and the United States.
Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries.
App Store is a service mark of Apple Inc., registered in the U.S. and other countries. Google Play
and the Google Play logo are trademarks of Google Inc.
The Wi-Fi CERTIFIED™ Logo is a certification mark of Wi-Fi Alliance®
10 sec.