INSTALLATION INSTRUCTIONS

WS-70018


Phone (800) 526.2588
Fax (800) 526.2585

44 Harbor Park Drive
Port Washington, NY 11050

1600 Distribution Ct
Lithia Springs, GA 30122

1750 Archibald Avenue
Ontario, CA 91760


• Read all instructions before installing.
• System is intended for installation by a licensed electrician in accordance with the National Electrical Code (NEC) and local regulations.
When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
• Retain installation instructions for future maintenance reference.
All parts must be used as indicated in these instructions. This product is designed for use only with the supplied parts and/or
accessories designated for use by Modern Forms. Substitution of parts or accessories not designated for use with this product by Modern
Forms could result in personal injury or property damage, and will void the warranty. Contact an authorized dealer or the manufacturer if any
parts are damaged or missing.
Coastal conditions may cause mineral and residue build-up on the xture. We recommend that customers in coastal
areas clean all external surfaces of the xture once every two weeks with a wet cloth.
Pour éviter tout choc électrique, assurez-vous que le disjoncteur soit mis hors tension avant de commencer.
• Lisez toutes les instructions avant l’installation.
• Le système doit être installé par un électricien licensié conformément au code national de l’électricité (NEC), et également aux
règlements locaux.
• Lors de la manipulation du luminaire, n’appuyez pas sur les LED. Tenez-le uniquement par la base.
Toutes les pièces doivent être utilisées comme indiqué dans ces instructions. Ce produit est conçu pour être utilisé seulement
avec les pièces et/ou accessoires fournis pour être utilisés avec les produits Modern Forms. Remplacer des pièces ou accessoires non conçus
pour ce produit Modern Forms pourrait causer des dommages corporels ou matériels et pourrait également causer l’annulation de la
garantie. Veuillez contacter un revendeur autorisé ou le fabricant si des pièces manquent ou sont endommagées.
 Les conditions côtières peut causer une accumulation de minéraux et de résidue sur le luminaire. Nous recommendons
aux clients qui resident dans les zones côtières de nettoyer toutes les surfaces externes du luminaire une fois toutes les deux semaines avec
un chion humide.
Wire Connector
Qty: 3 PCS+1Extra
Mounting Screw
Qty: 1Extra
Knurling Screw
Qty: 2PCS+1Extra
&
'
%
$ (
Fix Screw
Qty: 2PCS+1Extra
Gasket
Qty: 4PCS+1Extra
Plastic Anchor
Qty: 1PC+1Extra
Wood Screw
Qty: 1PC+1Extra
) *
2
INSTALLATION INSTRUCTIONS
WS-70018
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Phone (800) 526.2588
Fax (800) 526.2585
44 Harbor Park Drive
Port Washington, NY 11050
1600 Distribution Ct
Lithia Springs, GA 30122
1750 Archibald Avenue
Ontario, CA 91760
parts on a clear area. Be careful not to lose any small
parts necessary for installation.
4. Drill holes in the wall aligned with the key holes located in the U bracket,
insert the plastic anchors (F).
5. Secure the mounting back plate to the junction box using standard
junction box screws that comes with the junction box.
Note: (i)using any other non-original- manufacturer Provided junction box
screw may result in safty issue;
(ii) The side of the mounting plate marked “GND” must face out.
6. Connect the driver’s input wires to junction box wires as shown in
Fig. 2,making sure that all wire connectors (A) are secured. If your outlet
wires are connected,
tuck them carefully inside the junction box.
7. Secure the U bracket to the wall by fastening the wood screws (G) to the plastic anchors (F),When you think the gap between the down
canopy and the wall is too large.T his is an optional step
10. Place the shade cover on the notch of the lamp body.
ing wires
information.
13. To utilize ELV or TRAIC dimming: use wires black (hot), white (neutral) and bare copper ground wire (ground).
14. To utilize 0-10V dimming: use wire purple (dim+), Pink or gray (dim-), black (hot), white (neutral) and bare copper ground wire (ground).
Ground Wire Mounting
Backplate
Acrylic
(
RPL-GLA-70018
)
SHADE
(RPL-SHA-70018)
Knurling Screw
Fix Screw
Mounting
Screw
Gasket
A
B
C
D
E
Plastic Anchor
F
Wood Screw
G
Driver:
5 3/10"[L] x 2 3 /5"[W] x 3/5"[H]
13
8
"
13
4
"
41
8
"
93
8
"
P
urple - Dim-
Pink or Gray - Dim-
Black - To Fixture -
Red - To Fixture + Green - Ground