Z-Wave® Certified Wireless Lighting Control
Certifié Z-Wave Commande d’éclairage sans fil
Control inalámbrico para iluminación certificado por Z-Wave®
14326
ZW3006
In-wall Wireless
Smart Dimmer (1000w)
Montage mural
Intelligent Gradateur
sans fil (1000w)
Interruptor de pared
reductor inalámbrico
de luz inteligente (1000w)
A
B
C
E
DF
White (Neutral)
Green (Ground)
Black (Line / Hot)
Z-Wave
Single
Switch
Black
(Load)
Scan to view
installation guide
Balayez ce code pour
consulter le guide
d’installation.
Escanear para ver
la guía de instalación
MANUAL • MANUEL • MANUAL
14326 UL v2
WARRANTY
JASCO Products warrants this product to be free from manufacturing defects for a period of
two years from the original date of consumer purchase. This warranty is limited to the repair or
replacement of this product only and does not extend to consequential or incidental damage to
other products that may be used with this product. This warranty is in lieu of all other warranties,
expressed or implied. Some states do not allow limitations on how long an implied warranty
lasts or permit the exclusion or limitation of incidental or consequential damage, so the above
limitations may not apply to you. This warranty gives you specic rights, and you may also have
other rights which vary from state to state. Please contact Customer Service at 800-654-8483
(option 1) between 7:30AM – 5:00PM CST or via our website (www.jascoproducts.com) if the
unit should prove defective within the warranty period.
GARANTIE
JASCO Products garantit que ce produit est exempt de tout défaut de fabrication pour une
période de deux ans à compter de la date de l’achat original par l’acheteur. Cette garantie se
limite exclusivement à la réparation ou au remplacement de ce produit et n’est pas applicable
aux dommages indirects ou accessoires survenus sur d’autres produits utilisés avec ce
produit. Cette garantie se substitue à toute autre garantie expresse ou implicite. Certains
États ne permettent pas de restrictions quant à la durée d’une garantie implicite ou permettent
l’exclusion ou la limitation des dommages indirects et accessoires; il se peut, par conséquent,
que cette garantie ne s’applique pas dans votre cas. Cette garantie vous confère des droits
juridiques précis; vous pouvez jouir d’autres droits qui peuvent varier d’un État à l’autre. Veuillez
communiquer avec le service à la clientèle au 1-800-654-8483 (option 1) entre 7 h 30 et 17 h
(heure normale du Centre) ou par l’intermédiaire de notre site Web (www.jascoproducts.com) si
l’appareil s’avère défaillant au cours de la période de garantie.
GARANTÍA
JASCO Products garantiza que este producto está libre de defectos de fabricación durante
un periodo de dos años a partir de la fecha original de compra por parte del consumidor. Esta
garantía se limita a la reparación o sustitución de este producto solamente y no se extiende
a daños derivados o accidentales causados a otros productos que se usen con esta unidad.
Esa garantía remplaza a todas las demás garantías expresas o implícitas. Algunos estados no
autorizan limitaciones en cuanto a la duración de una garantía implícita ni permiten la exclusión
o limitación por daños accidentales o derivados; por lo tanto, puede que las anteriores
limitaciones no apliquen en su caso. Esta garantía le da a usted derechos especícos, y otros
que usted puede tener y que varían según el estado en el que usted reside. Si la unidad
resultare defectuosa dentro del periodo de garantía, comuníquese por favor con Atención al
Cliente en el 800-654-8483 (opción 1) entre 7.30 y 17 h, Hora del Centro, o a través de nuestro
sitio de internet.
JASCO Products Company, Building B
10 E Memorial Rd. Oklahoma City, OK 73114
SPECIFICATIONS
ZW3006
Power: 120 VAC, 60 Hz.
Signal Frequency: 908.4/916 MHz.
Minimum Load: 40W, incandescent lamps only.
Maximum Loads: 1000W, 2-gang 800W, and 3-gang 600W incandescent lamps only.
Wireless Range: Up to 150 feet line of sight from controller or closest Z-Wave receiver module.
Operating Temperature Range: 32-104° F (0-40° C)
For indoor use only.
Specications subject to change without notice due to continuing product improvement
SPÉCIFICATIONS
ZW3006
Power: 120 VAC, 60 Hz.
Signal Frequency: 908.4/916 MHz.
Minimum Load: 40W, incandescent lamps only.
Maximum Loads: 1000W, 2-gang 800W, and 3-gang 600W incandescent lamps only.
Wireless Range: Up to 150 feet line of sight from controller or closest Z-Wave receiver module.
Operating Temperature Range: 32-104° F (0-40° C)
For indoor use only.
Specications subject to change without notice due to continuing product improvement
ESPECIFICACIONES:
ZW3006
Power: 120 VAC, 60 Hz.
Signal Frequency: 908.4/916 MHz.
Minimum Load: 40W, incandescent lamps only.
Maximum Loads: 1000W, 2-gang 800W, and 3-gang 600W incandescent lamps only.
Wireless Range: Up to 150 feet line of sight from controller or closest Z-Wave receiver module.
Operating Temperature Range: 32-104° F (0-40° C)
For indoor use only.
Specications subject to change without notice due to continuing product improvement
MADE IN CHINA/FABRIQUÉ EN CHINE/HECHO EN CHINA
DISTRIBUTED BY
JASCO PRODUCTS COMPANY LLC,
10 E. MEMORIAL RD.,
OKLAHOMA CITY, OK 73114.
© JASCO 2015 | 14326 | ZW3006 | rev. 09/11/15 RT
The Jasco Add-on switch is required for Multi-Switch 3-way or 4-way installations.
Connecting the traveler terminal of this switch to a standard, non-Jasco switch will cause damage or result in improper
function. If this switch is a part of a 3-way or 4-way multi-switch installation, do not connect the traveler wire or apply
power until Jasco Add-on switches are correctly installed. For more information on 3-Way or 4-Way installations, view
the manual or quick-start guide that comes with the Jasco Add-on switch.
This Device supports Lifeline (association group 1) supporting 1 node for lifeline communication. Group 1 must be
assigned the Node ID of the primary controller where unsolicited notifications will be sent. The Z-Wave controller
should set this association automatically after inclusion. Lifeline association only supports the “Device Reset
Locally” function. Refer to the instructions of your controller for any available details on how this can be set.
Z-WAVE INTEROPERABILITY
This product can be included and operated in any Z-Wave network with
other Z-Wave certified devices from other manufacturers and/or other
applications. All non-battery operated nodes within the network will act
as repeaters regardless of vendor to increase reliability of the network.
5. To Change Color Of The Paddle
This step is optional. Before you start you may want
to change the color of the paddle to match your
wallplate or decor.
1. Lift the Air Gap tab at the base of the paddle.
2. Push side tabs in on one side and then the other
to release paddle. Lift the cover up and off.
3. Simply put the new paddle onto the switch by
inserting the air gap and side tabs and snapping
securely into place.
Once this step has been completed
please return to section 3.
All brand names shown are trademarks of their
respective owners.
Tous les noms de marque illustrés sont des
marques de commerce de leurs propriétaires
respectifs.
Todas las marcas que aparecen aquí son
marcas registradas de sus respectivos dueños.
From Breaker Box
Out to Light (Load)
A
E
D
C
From Breaker Box
Out to Light (Load)
A
E
D
C
OR
OR
3.
If you have any problems or questions, contact our tech support team
at; 1-800-654-8483, option 1 Monday–Friday, 7:30–5pm CST
For the most up-to-date product support, accessories, electronic (PDF) format
manuals and more, visit www.jascoproducts.com/support.
• No user servicable parts in this unit.
Si vous avez des problèmes ou des questions, communiquez avec notre
équipe de soutien technique au 1-800-654-8483, option1, du lundi au
vendredi, de 7 h 30 à 17 h (HNC).
Pour le soutien relatif aux produits le plus à jour, les accessoires,
les manuels en format électronique (PDF) et plus encore, visitez le site
www.jascoproducts.com/support.
• Aucune des pièces de ce dispositif ne peut être réparée par l’utilisateur.
Si tiene problemas o dudas, comuníquese con nuestro equipo técnico al
número: 1-800-654-8483, opción 1 de lunes a viernes, de 7:30 a 5 p.m., hora
estándar del centro (CST).
Para recibir el soporte técnico más actualizado sobre productos,
accesorios, manuales en formato digital (PDF), entre otros,
visite www.jascoproducts.com/support.
• Esta unidad no contiene piezas que el usuario pueda reparar.
STOP
DO NOT RETURN THIS
PRODUCT TO THE STORE
NE RETOURNEZ PAS
CE PRODUIT AU MAGASIN
NO DEVUELVA ESTE
PRODUCTO A LA TIENDA.
RISK OF FIRE
RISK OF ELECTRICAL SHOCK
RISK OF BURNS
CONTROLLING APPLIANCES:
CAUTION: TO REDUCE THE RISK OF OVERHEATING
AND POSSIBLE DAMAGE TO OTHER EQUIPMENT,
DO NOT INSTALL TO CONTROL A MOTOR-
OPERATED APPLIANCE, A FLUORESCENT
LIGHTING FIXTURE, OR A TRANSFORMER
SUPPLIED APPLIANCE.
• ONLY USE TO CONTROL INCANDESCENT OR
DIMMABLE CFL/LED BULBS
• DO NOT EXCEED RATINGS
• DO NOT USE TO CONTROL ANY DEVICE WHERE
UNINTENDED OPERATION COULD CAUSE
UNSAFE CONDITIONS (HEAT LAMP, SUN LAMP,
ETC.)
• FOR INDOOR USE ONLY
RIESGO DE INCENDIO
RIESGO DE DESCARGA ELÉCTRICA
RIESGO DE QUEMADURAS
CONTROL DE APARATOS:
PRECAUCIÓN: A FIN DE DISMINUIR EL RIESGO
DE RECALENTAMIENTO Y DE POSIBLES DAÑOS
EN LOS DEMÁS EQUIPOS, NO INSTALAR PARA
CONTROLAR APARATOS QUE FUNCIONAN A
MOTOR, ARTEFACTOS DE ILUMINACIÓN DE LUZ
FLUORESCENTE O APARATOS ALIMENTADOS CON
TRANSFORMADORES.
• USAR EXCLUSIVAMENTE PARA CONTROLAR
BOMBILLAS CFL/LED INCANDESCENTES O
ATENUABLES
• NO SUPERE LOS VALORES NOMINALES
ELÉCTRICOS
• NO USAR PARA CONTROLAR DISPOSITIVOS
• USE SOLAMENTE EN INTERIORES
NOT FOR USE WITH MEDICAL OR LIFE
SUPPORT EQUIPMENT
Z-WAVE ENABLED DEVICES SHOULD NEVER BE
USED TO SUPPLY POWER TO, OR CONTROL
THE ON/OFF STATUS OF MEDICAL AND/OR LIFE
SUPPORT EQUIPMENT.
NE PAS UTILISER AVEC UN ÉQUIPEMENT
MÉDICAL OU DE SURVIE
LES DISPOSITIFS COMPATIBLES AVEC LA
TECHNOLOGIE Z-WAVE NE DEVRAIENT
JAMAIS ÊTRE UTILISÉS POUR ALIMENTER OU
COMMANDER LA MISE EN MARCHE OU L’ARRÊT DE
L’ÉQUIPEMENT MÉDICAL OU DE SURVIE.
SE PROHÍBE SU EMPLEO EN
EQUIPO MÉDICO O EQUIPO PARA EL
MANTENIMIENTO DE LAS FUNCIONES
VITALES
LOS DISPOSITIVOS Z-WAVE NUNCA SE DEBEN
USAR PARA SUMINISTRAR ENERGÍA ELÉCTRICA
AL EQUIPO MÉDICO O AL EQUIPO PARA EL
MANTENIMIENTO DE FUNCIONES VITALES, NI
PARA CONTROLAR EL ESTADO DE ENCENDIDO O
APAGADO DE DICHOS EQUIPOS.
RISQUE D’INCENDIE
RISQUE DE CHOC ÉLECTRIQUE
RISQUE DE BRÛLURES
COMMANDE DES APPAREILS:
ATTENTION: POUR RÉDUIRE LE RISQUE DE
SURCHAUFFE ET DE DOMMAGES POSSIBLES
À D’AUTRES APPAREILS, NE PAS INSTALLER
POUR COMMANDER UN APPAREIL ACTIONNÉ
PAR MOTEUR, UN APPAREIL D’ÉCLAIRAGE
FLUORESCENT OU UN APPAREIL ALIMENTÉ PAR
UN TRANSFORMATEUR.
• UTILISER SEULEMENT POUR COMMANDER
LES AMPOULES À DEL ET FLUOCOMPACTES À
INCANDESCENCE OU À INTENSITÉ RÉGLABLE
• NE PAS DÉPASSER LES CARACTÉRISTIQUES
NOMINALES
• NE PAS UTILISER POUR COMMANDER
DES APPAREILS POUR LESQUELS UN
FONCTIONNEMENT IMPRÉVU POURRAIT
ENTRAÎNER DES CONDITIONS DANGEREUSES
(LAMPE À RAYONS INFRAROUGES, LAMPE
SOLAIRE, ETC.)
• POUR UTILISATION INTÉRIEURE UNIQUEMENT
AVERTISSEMENT
WARNING ADVERTENCIA
En
This device complies with part 15 of the FCC and Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
FCC NOTE: The manufacturer is not responsible for any radio or TV interference caused by
unauthorized modications to this equipment. Such modications could void the user’s authority
to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
— Consult the dealer or an experienced radio/TV technician for help
Important note: To comply with the FCC RF exposure compliance requirements, no change
to the antenna or the device is permitted. Any change to the antenna or the device could result
in the device exceeding the RF exposure requirements and void user’s authority to operate the
device.
FCC / IC
Es
Este dispositivo cumple con las Especicaciones del apartado 15 de las normas de la FCC y con
las especicaciones de las normas radioeléctricas (RSS) del Ministerio de Industria de Canadá
aplicables a aparatos exentos de licencia. El funcionamiento está sujeto a las siguientes dos
condiciones: (1) este dispositivo no debe provocar interferencia perjudicial, y (2) este dispositivo
debe aceptar toda interferencia que reciba, incluso la que pudiera causar un funcionamiento no
deseado.
NOTA DE LA FCC: El fabricante no se hace responsable de ninguna interferencia de radio o TV
ocasionada por modicaciones no autorizadas efectuadas a este equipo. Dichas modicaciones
podrían anular la autoridad del usuario para utilizar el equipo.
NOTA: Este equipo ha sido probado y cumple con los límites para aparatos digitales de Clase B,
de conformidad con el apartado 15 de las normas de la FCC. Estos límites están diseñados para
proveer protección razonable contra interferencias perjudiciales en una instalación residencial.
Este equipo genera, usa y puede irradiar energía de radiofrecuencias y, si no se instala y usa
según las instrucciones, puede provocar interferencia perjudicial a las radiocomunicaciones. No
obstante, no hay garantías de que no ocurrirá interferencia en una instalación en particular. Si
este equipo provoca interferencia perjudicial a la recepción de radio o televisión, lo que puede
determinarse encendiendo y apagando el equipo, se recomienda que el usuario intente corregir
la
interferencia por medio de la implementación de una o más de las siguientes medidas:
— Reorientar o reubicar la antena receptora.
— Incrementar la separación entre el equipo y el receptor.
— Conectar el equipo a un tomacorriente de un circuito diferente del circuito al que está
conectado el receptor.
— Consultar al distribuidor o a un técnico con experiencia en radio/televisión para
solicitar asistencia.
Nota importante: Para cumplir con los requisitos de cumplimiento de exposición de
radiofrecuencia de la FCC, no se permiten cambios a la antena o el dispositivo. Cualquier cambio
a la antena o dispositivo podría hacer que el dispositivo supere los requerimientos de exposición
de radiofrecuencia y anular la autoridad del usuario para operar el dispositivo.
FCC — U2ZZW3006A | IC: 6924A-ZW3006A
Jasco Products Company | Model: ZW3006 / 14326
CAN ICES-3(B) / NMB-3(B)
Fr
Cet appareil est conforme au paragraphe 15 des normes FCC et au CNR pour les appareils
exempts de licence d’Industrie Canada. Son utilisation est sujette aux deux conditions suivantes :
1) cet appareil ne doit pas occasionner de brouillage préjudiciable et 2) cet appareil doit
accepter toutes les interférences reçues, notamment les interférences qui peuvent provoquer un
fonctionnement non désiré.
NOTE DE LA FCC : Le fabricant n’est pas responsable des interférences sur les fréquences
radioélectriques ou télévisuelles pouvant être causées par des modications non autorisées de
ce matériel. De telles modications peuvent annuler le droit de l’utilisateur à utiliser cet appareil.
REMARQUE : Cet appareil a été testé et certié conforme aux limites relatives aux appareils
numériques de catégorie B dénies dans le paragraphe 15 des normes FCC. Ces limites ont
été dénies an de fournir une protection raisonnable contre le brouillage préjudiciable en milieu
résidentiel. Cet appareil produit, utilise et peut émettre des ondes de fréquence radio et, s’il n’est
pas installé et utilisé conformément aux instructions, il peut provoquer un brouillage préjudiciable
aux communications radio. Il n’existe toutefois aucune garantie que des interférences ne se
produiront pas au sein d’une installation donnée. Si cet appareil occasionne un brouillage
préjudiciable à la réception radiophonique ou télévisuelle, il suft d’allumer et d’éteindre l’appareil
pour déterminer sa responsabilité. Nous encourageons l’utilisateur à essayer de corriger ces
interférences en appliquant une ou plusieurs des mesures suivantes :
— Réorienter ou déplacer l’antenne de réception.
— Augmenter la distance entre l’appareil et le récepteur.
— Brancher l’appareil à une prise secteur différente de celle du récepteur.
— Consulter le revendeur ou un technicien spécialisé en postes radio ou téléviseurs.
Remarque importante : Pour se conformer aux exigences de conformité de la FCC concernant
l’exposition aux RF, aucune modication apportée à l’antenne ou au dispositif n’est autorisée.
Toute modication apportée à l’antenne ou au dispositif pourrait faire en sorte que le dispositif
dépasse les exigences d’exposition aux RF et pourrait annuler le droit de l’utilisateur à utiliser ce
dispositif.
Out to Light (Load)
A
D
E
C
B
From Breaker Box
Multi-switch wiring
For 3-way installations, please refer to Add-on Switch manual
Single switch wiring
Before you start; you may wish to change the paddle to match your wallplate or decore.
Please proceed to section 5.
1. Shut off power to the circuit at circuit breaker or fuse box.
IMPORTANT! Verify power is OFF to switch box before continuing.
2. Remove wall plate.
3. Remove the switch mounting screws.
4. Carefully remove the switch from the switch box. DO NOT disconnect the wires.
There are up to four screw terminals on the switch; these are marked
A. LINE (Hot) — Black (connected to power)
WARNING — SHOCK HAZARD
Turn OFF the power to the branch circuit for the switch and lighting xture at the
service panel. All wiring connections must be made with the POWER OFF to avoid
personal injury and/or damage to the switch.
This device is intended for installation in accordance with the National Electric Code
and local regulations in the United States, or the Canadian Electrical Code and local
regulations in Canada. If you are unsure or uncomfortable about performing this
installation consult a qualied electrician.
B. NEUTRAL — White (this terminal is not used for the installation process)
C. LOAD — Black (connected to lighting)
D. GROUND — Green/Bare
E. TRAVELER — Red/Other (only in 3-way installations)
Match these screw terminals to the wires connected to the existing switch.
5. Disconnect the wires from the existing switch. Be careful to label wires according to the
previous terminal connection.
Observe Important Wiring Information
IMPORTANT!: This Dimmer is rated for and intended to only be used with copper wire.
Wire Gauge Requirements
Use 14 AWG or larger wires suitable for at least 80° C for supplying Line (HOT), Load,
Neutral, Ground and Traveler connections.
Wire strip length:
For attachment to screw terminals: Strip insulation 1” (25mm)
For attachment using the enclosure’s holes: Strip insulation 5/8” (16mm)
UL species that the tightening torque for the screws is 14 Kgf-cm (12 lbf-in).
1. Connect the green or bare copper ground wire to the GROUND terminal.
2. Connect the black wire that goes to the light to the terminal marked LOAD.
3. Connect the black wire that comes from the electrical service panel (Hot) to the terminal
marked LINE.
4. Connect the white wire to the neutral terminal (use jumper wire [not included] if needed).
Note: The Traveler terminal is only used for 3-way or 4-way wiring and should remain
insulated if the switch is being installed in a 2-way system (one switch & one load).
5. Insert Dimmer into the switch box being careful not to pinch or crush wires.
6. Secure the Dimmer to the box using the supplied screws.
7. Mount the wall plate.
8. Reapply power to the circuit at fuse box or circuit breaker and test the system.
Basic Operation
The connected light can be turned ON/OFF and adjust dim levels in two ways:
1. Manually from the front panel of the In-wall Dimmer
2. Remotely with a Z-Wave Controller
Manual Control
The Front Panel Rocker Dimmer allows the user to:
Turn ON/OFF the connected xture.
To turn the connected xture ON: Press and release the top of the rocker.
To turn the connected xture OFF: Press and release the bottom of the rocker.
Adjust dim level
To increase brightness: press and hold the top of the rocker
To decrease brightness: press and hold the bottom of the rocker.
1. Tools You Will Need
• Turn ON/OFF and adjust dim levels manually or remotely via the Z-Wave controller
• Can be Included in multiple Groups and Scenes
• May be used in single pole installation or with up to two Jasco Add-on switches in 3-way or
4-way wiring configurations
• Compatible with incandescent and halogen bulbs only
• Interchangeable Paddle switch — White & light almond paddle in package
• Uses a standard, decorative-size wall plate for single gang installations (wall plate not included)
• Blue LED indicates switch location in a dark room
• Z-Wave Certified for simple pairing and integrated home automation
• Screw Terminal Installation — requires wiring connections for Line (Hot), Load, Neutral, and
Ground. Traveler wire required for 3-way or 4-way installation
• This device supports lifeline (association group 1)
• This Z-Wave device has advanced features that allow you to customize your experience.
These features can only be adjusted by a Z-Wave enabled controller that support the
Z-Wave Configuration command class. For a complete list of Adjustable Configurations,
visit: www.jascoproducts.com/z-waveconfig
Getting To Know Your New Z-Wave Device
IMPORTANT!
The xture controlled by the Z-Wave In-wall Smart Dimmer must not exceed
1000 watts (Incandescent). Not for use with CFL or LED lighting.
Single, Dual And Triple Gang Boxes
When installing the In-wall Smart Dimmer in multiple gang boxes it may be
necessary to break off one or both sides of the scored tabs on the front yoke.
This will affect the electrical rating of the switch (see specifications for details).
2.
A. Top Rocker — (Press &
release to turn Dimmer on,
press & hold increases
brightness)
B. Bottom Rocker — (Press
& release to turn Dimmer off,
press & hold to dim)
C. Ground (Green/Bare)
D. Load (Black)
E. Line (Black)
F. Traveler (Red/Other)
Adding your device to a Z-wave network
1. Follow the instructions for your Z-wave certified controller to include a device to the Z-wave
network.
2. Once the controller is ready to include your device, press and release the top or bottom of the
wireless smart switch(rocker) to include it in the network.
3. Once your controller has confirmed that the device has been included, refresh the Z-wave network
to optimize performance.
Please reference the controller’s manual for instructions.
Now you have complete control to turn your fixture ON/OFFaccording to groups, scenes, schedules
and interactive automations programmed by your controller.
If your Z-wave certified controller features Remote Access, you can now control your fixture from
your mobile devices.
To exclude and reset the device
1. Follow the instructions for your Z-wave certified controller to exclude a device from the Z-wave
network.
2. Once the controller is ready to Exclude your device, press and release the top or bottom of the
wireless smart dimmer (rocker) to exclude it from the network.
To return your switch to factory defaults:
Quickly press ON (Top) button three (3) times then immediately press the OFF (Bottom) button three
(3) times. The LED will flash ON/OFF 5 times when completed successfully.
Note: This should only be used in the event your network’s primary controller is
missing or otherwise inoperable.
4.