Frigidaire FFGH3054UB Manuel utilisateur

Catégorie
Micro-ondes
Taper
Manuel utilisateur
1
INSTALLATION INSTRUCTIONS
FRONT CONTROL FREESTANDING GAS RANGE
INSTALLATION AND SERVICE MUST BE
PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
IMPORTANT SAFETY INSTRUCTIONS
If the information in this manual is not
followed exactly, a re or electrical shock may result causing
property damage, personal injury or death.
FOR YOUR SAFETY:
Do not store or use gasoline or other ammable vapors
and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the re
department.
Installation and service must be performed by a qualied
installer, service agency or the gas supplier.
Important Notes to the Installer:
Read all instructions contained in these installation
instructions before installing range.
Remove all packing material from the oven
compartments before connecting the gas & electrical
supply to the range.
Observe all governing codes and ordinances.
Be sure to leave these instructions with the
consumer.
Important Notes to the Consumer:
Keep these instructions with your owner’s guide for
future reference.
As when using any appliance generating heat, there
are certain safety precautions you should follow.
These are listed in the Use & Care Guide, read it
carefully.
Tip Over Hazard
Range
leveling leg
Anti-tip
bracket
• A child or adult can tip the
range and be killed.
• Verify the anti-tip device has
been installed to floor or wall.
• Ensure the anti-tip device is re-engaged to floor
or wall when the range is moved.
• Do not operate the range without the anti-tip
device in place and engaged.
• Failure to follow these instructions can result in
death or serious burns to children and adults.
To check if the anti-tip bracket is installed properly, use
both arms to grasp the rear edge of the range back.
Carefully attempt to tilt range forward. When properly
installed, the range should not tilt forward.
Refer to the anti-tip bracket installation instructions
supplied with your range for proper installation.
FOR YOUR SAFETY: Do not
store or use gasoline or other ammable
vapors and liquids in the vicinity of this or
any other appliance.
Be sure your range is installed and grounded properly
by a qualied installer or service technician.
Make sure the wall coverings around the range can
withstand the heat generated by the range.
To eliminate the need to reach over the surface
elements, cabinet storage space above the elements
should be avoided.
P/N 809127205 (1804) Rev. A
English – pages 1-13
French – pages 14-26
Spanish – pages 27-40
2
30” GAS FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
Provide proper fuel type
Before proceeding: Your range is factory preset to operate
on natural gas. If L.P. conversion is needed, contact your
local L.P. Gas provider for assistance.
The L.P. conversion kit may be located on the lower rear
back panel of the range. If no L.P. kit is provided, contact
your product dealer to obtain the correct L.P. conversion
kit.
Installation of this range must conform with local codes
or, in the absence of local codes, with the National
Fuel Gas Code ANSI Z223.1—latest edition when
installed in the United States.
When installed in a manufactured (mobile) home,
installation must conform with the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part
3280 [formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD (Part 280)] or,
when such standard is not applicable, the Standard
for Manufactured Home Installations, ANSI/NCSBCS
A225.1, or with local codes.
This range has been design certied by CSA
International. As with any appliance using gas and
generating heat, there are certain safety precautions
you should follow. You will nd them in the Use & Care
Guide, read it carefully.
Be sure your range is installed and grounded properly
by a qualied installer or service technician.
This range must be electrically grounded in
accordance with local codes or, in their absence, with
the National Electrical Code ANSI/NFPA No .70—
latest edition when installed in the United States. See
Grounding Instructions on page 9.
Before installing the range in an area covered with
linoleum or any other synthetic oor covering, make
sure the oor covering can withstand heat at least
90°F above room temperature without shrinking,
warping or discoloring. Do not install the range over
carpeting unless you place an insulating pad or sheet
of 1/4-inch thick plywood between the range and
carpeting.
Make sure the wall coverings around the range can
withstand the heat generated by the range.
Do not obstruct the ow of combustion air at the oven
vent nor around the base or beneath the lower front
panel of the range. Avoid touching the vent openings
or nearby surfaces as they may become hot while the
oven is in operation. This range requires fresh air for
proper burner combustion.
Air curtain or other overhead range hoods, which
operate by blowing a downward air ow on to a range,
shall not be used in conjunction with gas ranges other
than when the hood and range have been designed,
tested and listed by an independent test laboratory for
use in combination with each other.
DO NOT MAKE ANY ATTEMPT TO
OPERATE THE ELECTRIC IGNITION OVEN DURING
AN ELECTRICAL POWER FAILURE. RESET ALL OVEN
CONTROLS TO “OFF” IN THE EVENT OF A POWER
FAILURE.
The electric ignitor will automatically re-ignite the oven
burner when power resumes if the oven thermostat control
was left in the “ON” position.
When an electrical power failure occurs during use, the
surface burners will continue to operate.
During a power outage, the surface burners can be lit with
a match. Hold a lighted match to the burner, then slowly
turn the knob to the LITE position. Use extreme caution
when lighting burners this way.
3
30” GAS FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
Never leave children alone or
unattended in the area where an appliance is in use. Teach
children the proper, safe use of all appliances. Never leave
the oven door open when the range is unattended.
Stepping, leaning or sitting on the doors or
drawers of this range can result in serious injuries and can
also cause damage to the range.
Do not store items of interest to children in the
cabinets above the range. Children could be seriously
burned climbing on the range to reach items.
To eliminate the need to reach over the surface
burners, cabinet storage space above the burners
should be avoided.
Adjust surface burner ame size so it does not extend
beyond the edge of the cooking utensil. Excessive
ame is hazardous.
Do not use the oven as a storage space. This creates
a potentially hazardous situation.
Never use your range for warming or heating the
room. Prolonged use of the range without adequate
ventilation can be dangerous.
Do not store or use gasoline or other ammable
vapors and liquids near this or any other appliance.
Explosions or res could result.
Reset all controls to the “OFF” position after using a
programmable timing operation.
Unlike some gas ranges, the cooktop is not removable.
Do not attempt to remove the cooktop.
Special instructions for appliances installed in the state of
Massachusetts:
This Appliance can only be installed in
the state of Massachusetts by a Massachusetts licensed
plumber or gas tter. When using a exible connector, it
must not exceed three (3) feet (36 in.) long. A “T” handle
type manual gas valve must be installed in the gas supply
line to this appliance.
4
30” GAS FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
1. Clearances and Dimensions
a. Provide adequate clearances between the range and adjacent combustible surfaces.
b. Location—Check location where the range will be installed. Check for proper electrical supply and gas supply and the stability of oor.
c. Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must be
solid and level.
WALL
OR
CABINET
WALL
OR
CABINET
Gas location
Open space
for gas
This space
must
remain clear
5”
30” Minimum*
Minimum to
wall on either
side of range
above 36” height.
36”
18”
Minimum to
cabinets on
either side
of range
25” Max.
13”
Maximum depth
for cabinets
above range top.
0” clearance below cooking top and at rear of range
Typical cabinet installationFront
view
Side
view
30”
Minimum
30”
Minimum
*30" (762 mm) MINIMUM CLEARANCE BETWEEN THE
TOP OF THE COOKING SURFACE AND THE BOTTOM
OF AN UNPROTECTED WOOD OR METAL CABINET; OR
24" (610 mm) MINIMUM WHEN BOTTOM OF WOOD OR
METAL CABINET IS PROTECTED BY NOT LESS THAN
1/4" (6 mm) FLAME RETARDANT MILLBOARD COVERED
WITH NOT LESS THAN NO. 28 MSG SHEET STEEL, 0.015"
(0.4 mm) STAINLESS STEEL, 0.024" (0.6 mm) ALUMINUM
OR 0.020" (0.5 mm) COPPER. 0" (0 mm) CLEARANCE IS
THE MINIMUM FOR THE REAR OF THE RANGE. FOLLOW
ALL DIMENSION REQUIREMENTS PROVIDED ABOVE
TO PREVENT PROPERTY DAMAGE, POTENTIAL FIRE
HAZARD, AND INCORRECT COUNTERTOP AND CABINET
CUTS.
TO ELIMINATE THE RISK OF BURNS OR FIRE BY
REACHING OVER HEATED SURFACE UNITS, CABINET
STORAGE SPACE LOCATED ABOVE THE SURFACE UNITS
SHOULD BE AVOIDED. IF CABINET STORAGE IS TO BE
PROVIDED, THE RISK CAN BE REDUCED BY INSTALLING
A RANGE HOOD THAT PROJECTS HORIZONTALLY A
MINIMUM OF 5" (127 mm) BEYOND THE BOTTOM OF
THE CABINETS.
DO NOT MAKE ANY ATTEMPT TO
OPERATE THE ELECTRIC IGNITION OVEN DURING
AN ELECTRICAL POWER FAILURE. RESET ALL OVEN
CONTROLS TO OFF IN THE EVENT OF A POWER
FAILURE. The electric ignitor will automatically re-
ignite the oven burner when power resumes if the oven
thermostat control was left in the ON position.
When an electrical power failure occurs during use, the
surface burners will continue to operate.
During a power outage, the surface burners can be lit
with a match. Hold a lighted match to the burner, then
slowly turn the knob to the Lite position. Use extreme
caution when lighting burners this way.
29
7
/
8
"
Maximum
36
5
/
8
"
±
1
/
4
"
26
6
/
8
"
47"
Door open
8"
4
1
/
3
"
12
1
/
16
"
24
1
/
8
"
22
5
/
8
"
4"
6
1
/
2
"
Fig.1
Fig.2
Fig.3
5
30” GAS FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
2. Tools You Will Need
Fig. a
(Wear safety glasses when using tools):
For leveling legs and Anti-Tip Bracket:
Adjustable wrench or channel lock pliers (Fig. a)
5/16” Nutdriver or at head screwdriver (Fig. b)
Electric drill & 1/8” drill bit (3/16” Masonry drill bit if
installing in concrete) (Fig. c)
Level (Fig. d)
For gas supply connection:
Adjustable wrench and pipe wrench (Figs. a & e)
For burner ame adjustment:
Phillips head and small at-blade screwdrivers (Figs. f
& g)
Materials you will need:
Pipe joint sealant that resists action of LP/Propane gas
(Fig. h)
Gas line manual shut-off valve (Fig. i)
A new exible metal appliance conduit (1/2” NPT x
3/4” or 1/2” I.D.) must be design certied by CSA
International. Because solid pipe restricts moving the
range, we recommend using a new exible conduit
(4 to 5 foot length) for each new installation and
additional reinstallations. (Fig. j)
Use new are union adapters (1/2” NPT x 3/4” or 1/2”
I.D.) (Fig. k)
Materials supplied with appliance:
Anti-Tip Template (Fig. l)
Anti-Tip bracket; includes 2 mounting screws (Fig. m)
Tools
Fig. f
Materials
Fig. h
Fig. i
Fig. j
Fig. k
Fig. d
Fig. c
Fig. g
Fig. b
Fig. e
Fig. l
Fig. m
Materials supplied with appliance
6
30” GAS FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
For oor mount, locate the bracket by placing back edge
of the template where the rear of the range will be located.
Mark the location of the screw holes, shown in template.
B. Drill Pilot Holes and Fasten
Bracket - Drill a 1/8” (3 mm)
pilot hole where screws are
to be located. If bracket is to
be mounted to the wall, drill
pilot hole at an approximate
20° downward angle. If
bracket is to be mounted to
masonry or ceramic oors,
drill a 5/32” (4 mm) pilot hole
1-3/4” (44 mm) deep. The
screws provided may be
used in wood or concrete material. Use a 5/16” (8 mm)
nut-driver or at head screwdriver to secure the bracket
in place.
C. Level and Position Range - Level range by adjusting the
(4) leveling legs with a wrench. Note: Aminimum clearance
of 1/8” (3 mm) is required between the bottom of the
range and the leveling leg to allow room for the bracket.
Use a spirit level to check your adjustments. Slide range
back into position. Visually check that rear leveling leg
is inserted into and fully secured by the Anti-Tip Bracket
by removing lower panel or storage drawer. For models
with a warmer drawer or broiler compartment, grasp the
top rear edge of the range and carefully attempt to tilt it
forward.
3. Anti-Tip Bracket Installation
Instructions
Important Safety Warning
To reduce the risk of tipping of the range, the range should
be secured to the oor by properly installed anti-tip bracket
and screws packed with the range. Failure to install the
anti-tip bracket will allow the range to tip over if excessive
weight is placed on an open door or if a child climbs upon
it. Serious injury might result from spilled hot liquids or from
the range itself.
If range is ever moved to a different location, the anti-tip
brackets must also be moved and installed with the range.
Instructions are provided for installation in wood or cement
fastened to either the oor or wall. When installed to the
wall, make sure that screws completely penetrate dry wall
and are secured in wood or metal. When fastening to the
oor or wall, be sure that screws do not penetrate electrical
wiring or plumbing.
A. Locate the Bracket Using the Template - (Bracket may be
located on either the left or right side of the range. Use
the information below to locate the bracket if template is
not available). Mark the oor or wall where left or right
side of the range will be located. If rear of range is against
the wall or no further than 1-1/4" (32 mm) from wall when
installed, you may use the wall or oor mount method. If
molding is installed and does not allow the bracket to t
ush against the wall, remove molding or mount bracket
to the oor. For wall mount, locate the bracket by placing
the back edge of the template against the rear wall and
the side edge of template on the mark made referencing
the side of the range. Place bracket on top of template
and mark location of the screw holes in wall. If rear of
range is further than 1-1/4" (32 mm) from the wall when
installed, attach bracket to the oor.
(31.75mm)
(31.75mm)
Fig. 4
Fig. 5
Fig. 6
Fig. 7
(17 mm)
7
30” GAS FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
Fig. 9
Be sure to stabilize the left side of the gas pressure
regulator before tightening ANY ttings to the pressure
regulator. Do not allow pressure regulator to turn on
pipe when tightening ttings (Refer to Fig. 9).
Fig. 8 - gas supply connections
Flare
union
adaptor
Flare
union
adaptor
Flexible appliance
conduit
Manual
shut-off
valve
Pressure
regulator
4. Provide an adequate gas
supply.
Please note: Operation at elevations above 2000 ft.,
appliance rating shall be reduced at the rate of 4 percent
for each 1000 ft. above sea level.
This appliance is pre-set to operate on 4” natural gas
manifold pressure. A convertible pressure regulator is
connected to the manifold and MUST be connected
in series with the gas supply line. If the LP/Propane
conversion kit has been used, follow instructions provided
with the kit for converting the pressure regulator to LP/
Propane use.
Care must be taken during installation of range not to
obstruct the ow of combustion and ventilation air.
For proper operation, the maximum inlet pressure to the
regulator should be no more than 14 inches of water
column pressure. The inlet pressure to the regulator must
be at least 1 inch greater than regulator manifold pressure.
Example: If regulator is set for natural gas 4 inch manifold
pressure, inlet pressure must be at least 5 inches; if
regulator has been converted for LP/Propane gas 10
inch manifold pressure, inlet pressure must be at least 11
inches.
Leak testing of the appliance shall be conducted according
to the instructions in step 4g.
The gas supply line should be 1/2” or 3/4” I.D.
5. Seal wall openings.
Seal any openings in the wall behind the range and in the
oor under the range after gas supply line is installed.
6.Connect range to gas
supply.
Note: To prevent leaks use pipe joint sealant on all male
(outside) pipe threads. Do not allow gas pressure reg-
ulator to turn on pipe when tightening ttings.
a. Install an external manual gas shut-off valve to gas
supply line in an accessible location outside of range.
Be sure you know where and how to shut off the gas
supply to the range (See Fig. 8).
b. Install 1/2” are union adapter to gas pressure
regulator using no more than 15ft./lbs. of torque (Refer
to Fig. 8).
8
30” GAS FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
OPEN CLOSED
Checking manifold gas pressure
Do not use ame to check for gas leaks.
Disconnect the range and its individual shut-off valve from
the gas supply piping system during any pressure testing
of that system at test pressures greater than 14” of water
column pressure (approximately 1/2” psig).
The appliance must be isolated from the gas supply
piping system by closing its individual manual shut-off
valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 14” of water
column pressure (approximately 1/2” psig).
If it should be necessary to check the manifold gas
pressure, connect manometer (water gauge) or other
pressure device to the top burner right rear orice. Using
a rubber hose with inside diameter of approximately 1/4,”
hold tubing down tight over orice. Turn burner valve on.
For an accurate pressure check have at least two (2)
other top burners burning. Be sure the gas supply (inlet)
pressure is at least one inch above specied range
manifold pressure. The gas supply pressure should never
be over 14” water column. When properly adjusted for
Natural Gas the manifold pressure is 4”. For LP/Propane
Gas the manifold pressure is 10”.
c. Tighten the gas supply tting and/or appliance conduit
to are union adaptor on the right side of the pressure
regulator (refer to Fig. 10) using NO MORE THAN
15ft./lbs. of torque. Be sure to stabilize the 1/2” are
union adapter with an adjustable wrench before
tightening the gas supply tting and/or appliance
conduit.
d. Install are union adapter to external manual shut-off
valve (See Fig. 8).
e. Attach exible appliance conduit to are union adaptor
on shut-off valve (See Fig. 8).
f. Make sure the service shut-off valve on pressure
regulator is set to the ON position (See Fig. 11).
Fig. 10
g. Check for gas leaks. Turn the gas supply on to the
range and use a liquid leak detector at all joints and
conduits to check for leaks in the system.
Fig. 11
Pressure
regulator
9
30” GAS FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
Grounding instructions:
The power cord of this appliance is equipped with a
3-prong (grounding) plug which mates with a standard
3-prong grounding wall receptacle to minimize the
possibility of electric shock hazard from this appliance.
The customer should have the wall receptacle and circuit
checked by a qualied electrician to make sure the
receptacle is properly grounded and polarized.
Fig. 13
Burner cap lip
Burner cap
Correct burner cap placement
Fig. 14
Incorrect burner cap placement
Fig. 15
Fig. 16
Do not, under any
circumstances, cut,
remove or bypass the
grounding prong.
Preferred method
Grounding
type wall
receptacle
Power
supply
cord with
3-prong
grounding
plug
Fig. 12
7. Read the following
electrical connection details
before connecting electricity
to range.
Before servicing, disconnect electrical sup-
ply at circuit breaker, fuse or power cord.
Electric requirements:
A dedicated, properly grounded and polarized branch
circuit protected by a 15 amp. circuit breaker or time delay
fuse. See serial plate for proper voltage.
Extension cord precautions:
Because of potential safety hazards under certain
conditions, we strongly recommend against the use of
any extension cord. However, if you still choose to use an
extension cord, it is absolutely necessary that it be a UL
listed 3-wire grounding type appliance extension cord and
that the current carrying rating of the cord in amperes be
equivalent to or greater than the branch circuit rating. Such
extension cords are obtainable through your local service
organization.
Please read carefully! For personal safety,
this product must be properly grounded.
Do not, under any circumstances, cut or remove the third
(ground) prong from the power cord (See Fig. 12).
Where a standard two-prong wall receptacle is
encountered, it is the personal responsibility and obligation
of the customer to have it replaced with a properly ground-
ed three-prong wall receptacle.
8. Check burner cap
placement.
It is very important to be sure that all surface burner caps
and burner grates are properly installed and in the correct
locations before operating the appliance. Please note that
the burner heads are secured to the cooktop. The cooktop
is not removeable. Do not attempt to remove or lift the
cooktop.
To prevent are-ups and avoid creation of
harmful by-products, do not use the cooktop without all
burner caps properly installed to insure proper ignition and
gas ame size.
Always keep the burner caps and burner heads in place
whenever the surface burners are in use. Do not allow
spills, food, cleaning agents or any other material to enter
the gas orice holder openings.
Check and be sure the size of each burner cap matches
the size of the burner head. Check and be sure that all
round style burner caps are correctly in place on round
burner heads.
Check and be sure that all oval style burner caps are cor-
rectly in place on oval burner heads (if equipped). Check
and be sure that all dual or twin style burner caps are cor-
rectly in place on dual or twin burner heads (if equipped).
On round style burners, the burner cap lip (See Fig. 13)
should t snug into the center of burner head and be level.
Refer to Figs. 14 & 15 for correct and incorrect burner cap
placement.
Once in place, you may check the t by gently sliding
the burner cap from side to side (Fig. 16) to be sure it
is centered and rmly seated. When the burner cap lip
makes contact inside the center of the burner head you will
be able to hear the burner cap click. Please note that the
burner cap should NOT move off the center of the burner
head when sliding from side to side.
10
30” GAS FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
Fig. 17
Burner ame size
5/8”
Cooktop
Fig. 18
9. Check ignition of surface
burners.
Operation of electric igniters should be checked after
range and supply line connectors have been carefully
checked for leaks and range has been connected to elec-
tric power.
a. To check for proper ignition, push in and turn a
surface burner knob counterclockwise to the LITE
position. You will hear the igniter sparking.
b. The surface burner should ignite when gas is available
to the burner. Purge air from supply lines by leaving
knob in the LITE position until burner ignites. Each
burner should light within four (4) seconds in normal
operation after air has been purged from supply lines.
c. Visually check that burner has a ame. Once the
burner ignites, the control knob should be turned out of
the LITE position.
d. Try each surface control knob separately until all
surface burners have been checked. Each burner
location is equipped with a separate electrode.
10. Adjust LOW setting of
surface burner valves (linear
ow).
Test to verify if LOW setting should be adjusted:
a. Push in and turn control to LITE until burner ignites.
b. Push in and quickly turn knob to lowest position.
c. If burner goes out, reset control to OFF.
d. Remove the surface burner control knob.
e. Insert a thin-bladed screwdriver into the hollow valve
stem and engage the slotted screw inside. Flame size
can be increased or decreased with the turn of the
screw (see Fig. 17 and Fig. 18).
f. Adjust ame until you can quickly turn knob from
LITE to lowest position without extinguishing the
ame. Flame should be as small as possible without
extinguishing.
Note: Air mixture adjustments are not required on surface
burners.
11. Check ignition of oven
burners.
The operation of oven igniters should be checked after
range and supply line connectors have been carefully
checked for leaks and range has been connected to elec-
tric power. Be sure all packing materials and literature are
removed from oven.
The oven burner is equipped with an electric control sys-
tem as well as an electric oven burner igniter. If your model
is equipped with an upper oven burner, it will also have
an electric burner igniter. These control systems require
no adjustment. When the oven is set to operate, current
will ow to the igniter. It will “glow” similar to a light bulb.
When the igniter has reached a temperature sufcient to
ignite gas, the electrically controlled oven valve will open
and ame will appear at the oven burner. There is a time
lapse from 30 to 60 seconds after the thermostat is turned
ON before the ame appears at the oven burner. When the
oven reaches the set temperature, the glowing igniter will
cycle off. The burner ame will turn off in 20 to 30 seconds
after the igniter turns off. To maintain any set oven
temperature, this cycle will continue as long as the oven
control is set to operate.
To check oven burner ignition:
a. Set oven to Bake at 300ºF. See User’s Manual for
operating instructions.
b. Within 60 seconds the oven burner should ignite.
Check for proper ame, and allow the burner to cycle
once. Reset control to OFF.
c. If your model is equipped with a waist-high broiler,
set oven to Broil. See User’s Manual for operating
instructions.
d. Within 60 seconds the broil burner should ignite.
Check for proper ame. Reset control to OFF.
11
30” GAS FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
To adjust lower oven air shut-
ter loosen lock screw (See
Fig. 20), reposition air shutter,
and tighten lock screw. When
nished adjusting replace
burner bafe and oven bottom
panel.
Fig. 19 - oven burner locations
Air shutter
Lock screw
Oven burner
Orice hood
Fig. 20 - typical oven
burner air shutter
13. Adjust air shutter - upper
oven (some models)
The approximate ame length of the upper (broil) burner
should be 1 inch having a distinct inner, blue ame. To
determine if the upper broil burner ame is proper, set the
oven to Broil. If the ame is yellow, increase upper oven
air shutter opening size. If the ame is a distinct blue,
reduce the air shutter opening size.
To adjust the upper air shutter loosen lock screw (See Fig.
20), reposition air shutter, and tighten lock screw.
14. Make sure range is level.
Level the range by placing a level horizontally on an oven
rack. Check diagonally from front to back, then level the
range by either adjusting the leveling legs or by placing
shims under the corners of the range as needed.
Note: After installation is complete, make sure all controls
are left in the off position.
Lower oven
bottom panel
(removable)
Lower oven
burner air
shutter
Lower oven
burner bafe
(removable)
Upper oven burner
(some models)
Upper oven burner air shut-
ter (some models)
12. Adjust air shutter - lower
oven.
To determine if the oven burner ame is proper, remove
the oven bottom panel and lower burner bafe (Refer to
Fig. 19) and set the oven to Bake at 300°F. The approx-
imate ame length of the lower oven burner should be 1
inch with a distinct inner blue ame.
To remove the lower oven bottom, remove oven bottom
hold down screws at rear of oven bottom panel. Pull up
at rear, disengage front of oven bottom from oven front
frame, and pull the oven bottom out of the oven. Remove
lower burner bafe to observe oven burner ame.
If the ame is yellow in color, increase the lower oven air
shutter opening size. If the ame is a distinct blue, reduce
the air shutter opening size.
12
30” GAS FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
15. Care, Cleaning and
Maintenance
Refer to the Use & Care Manual for cleaning instructions.
If removing the range is necessary for cleaning or
maintenance, shut off gas supply. Disconnect the gas
and electrical supply. If the gas or electrical supply is
inaccessible, lift the range slightly at the front and pull out
away from the wall. Pull out only as far as necessary to
disconnect the gas and electrical supply. Finish removing
the range for servicing and cleaning. Reinstall in reverse
order making sure to level the range and check gas
connections for leaks. Be sure to read and follow step 1 for
proper Anti-tip installation.
Some models have a cool-air intake vent on
the rear of the appliance. Do not block or obstruct this vent.
Before You Call for Service
Read the "Before You Call" and operating instruction sections
in your Use & Care Manual. It may save you time and expense.
The list includes common occurrences that are not the result
of defective workmanship or materials in this appliance.
Refer to the warranty in your Use & Care Manual for our
toll-free service number and address. Please call or write if
you have inquiries about your range product and/or need to
order parts.
16. Model and Serial Number
Location
The serial plate is located on the right-hand surface of the
oven front frame at the storage or warmer drawer; or the
lower panel area.
When ordering parts for or making inquires about your range,
always be sure to include the model and serial numbers and
a lot number or letter from the serial plate on your range.
Your serial plate also tells you the Kilowatt rating (power
requirements) and Voltage ratings.
Serial plate is located on the lower right front frame
of the appliance. Alternate location may be under
cooktop.
Serial Plate Locations:
13
30” GAS FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
NOTES
14
30” GAS FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
NOTICE D’INSTALLATION
CUISINIÈRE À GAZ AUTONOME
L’INSTALLATION ET L’ENTRETIEN DOIVENT ÊTRE RÉALISÉS PAR UN INSTALLATEUR QUALIFIÉ.
IMPORTANT : CONSERVEZ CES INSTRUCTIONS EN PRÉVISION D’UN USAGE ÉVENTUEL PAR
L’INSPECTEUR EN ÉLECTRICITÉ DE VOTRE LOCALITÉ. VEUILLEZ LIRE ET CONSERVER CES
INSTRUCTIONS POUR VOUS Y REPORTER ULTÉRIEUREMENT.
IMPORTANTES MESURES DE SÉCURITÉ
Si les directives contenues dans ce guide ne sont
pas suivies à la lettre, un feu ou une explosion pourrait se produire
et entraîner des dommages matériels, des blessures, voire la mort.
POUR VOTRE SÉCURITÉ :
Vous ne devez ni entreposer, ni utiliser d’essence ou d’autres
vapeurs ou liquides inammables à proximité de cet appareil ou
de tout autre appareil électroménager.
— QUE FAIRE SI VOUS DÉTECTEZ UNE ODEUR DE GAZ
Ne mettez pas d’appareil en marche.
Ne touchez à aucun commutateur électrique; ne vous
servez pas du téléphone de la maison.
En utilisant le téléphone d’un voisin, appelez immédiatement
le fournisseur de gaz. Suivez les directives données par
votre fournisseur de gaz
Si vous ne pouvez joindre votre fournisseur de gaz, appelez
les pompiers.
L’installation et l’entretien de cet appareil doivent être
réalisés par un installateur qualié, un technicien de service ou
le fournisseur de gaz.
Remarques importantes pour l’installateur
Lisez toutes les instructions contenues dans ce guide avant
de procéder à l’installation de la cuisinière.
Retirez tout le matériel d’emballage des compartiments du
four avant de connecter la cuisinière à l’alimentation en gaz
et à l’alimentation en électricité.
Respectez tous les codes et tous les règlements.
Assurez-vous de laisser ces instructions à l’utilisateur.
Remarque importante pour l’utilisateur
Conservez ces instructions avec le guide d’utilisation et
d’entretien pour vous y reporter ultérieurement.
Comme pour tout appareil produisant de la chaleur,
certaines précautions de sécurité doivent être respectées.
Ceux-ci sont répertoriés dans le Guide d’utilisation et
d’entretien, lisez-le attentivement.
Risque de basculement
Un enfant ou un adulte peut faire
basculer la cuisinière et en décéder.
• Vérifiez que le dispositif anti-renverse-
ment a été fixé au plancher ou au mur.
• Assurez-vous d’enclencher le dispositif anti-renversement
lorsque la cuisinière est déplacée sur le plancher ou contre le
mur.
Ne faites pas fonctionner la cuisinière si le dispositif anti-ren-
versement n’est pas en place et enclenché.
Le non-respect de ces instructions peut causer des blessures
fatales ou de graves brûlures aux enfants et aux adultes.
Pied de mise à
niveau de la
cuisinière
Support anti-
renversement
Pour vérifier si le support anti-renversement est correctement installé,
attrapez le bord arrière de la cuisinière à deux mains. et essayez
doucement de faire basculer la cuisinière vers l’avant. Lorsque le
support est correctement installé, la cuisinière ne doit pas basculer
vers l’avant.
Reportez-vous aux instructions d’installation du support anti-ren-
versement fournies avec la cuisinière pour vous assurer que
l’installation est effectuée de façon appropriée.
POUR VOTRE SÉCURITÉ : Vous
ne devez ni entreposer, ni utiliser d’essence ou d’autres
vapeurs ou liquides inammables à proximité de cet
appareil ou de tout autre appareil électroménager.
Assurez-vous que votre cuisinière est installée et mise à la
terre de façon appropriée par un installateur qualié ou un
technicien de service.
Assurez-vous que les revêtements muraux autour de la
cuisinière peuvent supporter la chaleur générée par la
cuisinière.
Pour éliminer le besoin d’atteindre les éléments de surface,
l’espace de rangement des armoires au-dessus des éléments
devrait être évité.
P/N 809127205 (1804) Rev. A
Anglais – páginas 1-13
Français – páginas 14-26
Español – páginas 27-40
15
INSTRUCTIONS D’INSTALLATION 30” CUISINIÈRE À GAZ AUTONOME
IMPORTANTES MESURES DE SÉCURITÉ
Type de gaz approprié
Avant de commencer : Votre cuisinière est préréglée en
usine pour fonctionner au gaz naturel. Si une conversion
au GPL est nécessaire, communiquez avec votre fournis-
seur de GPL pour obtenir de l’aide.
Il se peut qu’un nécessaire de conversion au GPL se
trouve sur le panneau du bas, à l’arrière de la cuisinière.
Si ce nécessaire de conversion n’est pas fourni, commu-
niquez avec votre marchand pour obtenir le nécessaire
approprié.
L’installation de cette cuisinière doit être faite
conformément aux codes locaux ou, si ce type
de code n’existe pas, au code national sur le gaz
combustible ANSI Z223.1 (dernière édition si l’appareil
est installé aux États-Unis).
Si la cuisinière est installée dans une maison
préfabriquée (maison mobile), l’installation doit
être conforme à la norme Manufactured Home
Construction and Safety Standard, titre 24 CFR, partie
3280 (anciennement désignée comme la Federal
Standard for Mobile Home Construction and Safety,
titre 24, HUD [partie 280]) ou, si cette norme ne
s’applique pas, l’installation doit être conforme à la
norme ANSI/NCSBCS A225.1 de la Standard for
Manufactured Home Installations, ou aux codes
locaux.
La conception de cette cuisinière a été approuvée
par CSA International. Comme dans le cas de tous
les appareils fonctionnant au gaz et produisant de la
chaleur, il est nécessaire de suivre certaines règles de
sécurité. Vous les trouverez dans le Guide d’utilisation
et d’entretien. Lisez-les attentivement.
Vériez que votre cuisinière est installée et mise à la
terre de façon appropriée par un installateur qualié ou
un technicien de service.
Cette cuisinière doit être mise à la terre conformément
aux codes locaux ou, en l’absence de tels codes,
conformément au National Electrical Code ANSI/NFPA
no 70 (dernière édition lorsque l’installation est faite
aux États-Unis). Reportez-vous aux instructions de
mise à la terre se trouvant à la page 22.
Avant d’installer la cuisinière dans un endroit recouvert
de linoléum ou de tout autre type de revêtement de sol
synthétique, assurez-vous que ce revêtement peut
supporter une chaleur se situant au moins à 50 ºC
(90 ºF) au-dessus de la température de la pièce sans
qu’il ne rétrécisse, ne gauchisse ou ne se décolore.
N’installez pas la cuisinière sur de la moquette,à moins
que vous placiez une plaque isolante en contreplaqué
d’une épaisseur de 0,6 cm (1/4 po) entre l’appareil et
la moquette.
Assurez-vous que le revêtement des murs qui se
trouve autour de la cuisinière peut supporter la chaleur
produite par celle-ci.
N’obstruez pas le débit d’air ni au niveau de l’évent du
four, ni autour de sa base. Ne bloquez pas non plus
le panneau avant inférieur de la cuisinière. Évitez de
toucher aux ouvertures de l’évent ou à la région située
près des surfaces, car celles-ci peuvent devenir très
chaudes lorsque le four fonctionne. Cette cuisinière
nécessite de l’air frais pour permettre une bonne
combustion des brûleurs.
Les rideaux d’air ou autres hottes de cuisinière en
hauteur qui projettent de l’air vers la cuisinière en
contrebas ne doivent pas être utilisés avec des
cuisinières à gaz, sauf si la hotte et la cuisinière ont
été conçues, testées et répertoriées par un laboratoire
d’essais indépendant et peuvent fonctionner
conjointement.
N’ESSAYEZ PAS DE FAIRE-
FONCTIONNER LE FOUR À ALLUMAGE ÉLECTRIQUE
DURANT UNE PANNE D’ÉLECTRICITÉ. REMETTEZ
TOUTES LES COMMANDES DU FOUR À LA POSITION
« OFF » (ARRÊT) EN CAS DE PANNE D’ÉLECTRICITÉ.
L’allumeur électrique rallumera automatiquement le brûleur
du four lorsque l’électricité reviendra, si les commandes du
thermostat du four ont été laissées à « ON » (marche).
Lorsqu’une panne d’électricité survient durant l’utilisation,
les brûleurs de surface continueront de fonctionner.
Durant une panne d’électricité, les brûleurs de surface
peuvent être allumés au moyen d’une allumette. Pour ce
faire, tenez une allumette allumée près du brûleur, puis
faites tourner lentement le bouton à la position « LITE »
(allumage). Faites preuve d’une grande prudence lorsque
vous allumez les brûleurs de cette façon.
16
INSTRUCTIONS D’INSTALLATION 30” CUISINIÈRE À GAZ AUTONOME
Ne laissez jamais un enfant seul ou-
sans surveillance à proximité d’un appareil électroménager
en marche. Enseignez aux enfants la manière d’utiliser les
appareils électroménagers de façon appropriée et sécu-
ritaire. Ne laissez jamais la porte du four ouverte lorsque
celui-ci est laissé sans surveillance.
Grimper, s’appuyer ou s’asseoir sur
les portes ou les tiroirs de la cuisinière peut causer des
blessures graves aux personnes ainsi que des dommages
à la cuisinière.
Ne rangez pas d’articles pouvant intéresser les
enfants dans les armoires se situant au-dessus de
la cuisinière. En voulant atteindre ces articles, les
enfants risqueraient de se brûler gravement.
Pour éliminer le besoin d’avoir à se pencher au-
dessus des brûleurs de surface, vous devriez éviter
de ranger des articles dans les armoires situées au-
dessus des brûleurs.
Réglez la amme du brûleur de surface pour qu’elle
ne dépasse pas du bord de l’ustensile de cuisson. Les
ammes excessives sont dangereuses.
N’utilisez pas le four comme espace de rangement.
Cela pourrait créer une situation potentiellement
dangereuse.
N’utilisez jamais votre cuisinière pour réchauffer
ou chauffer une pièce. Une utilisation prolongée de
la cuisinière sans aération adéquate peut s’avérer
dangereuse.
N’entreposez pas et n’utilisez pas d’essence ni
d’autres liquides et vapeurs inammables près de la
cuisinière ou de tout autre appareil électroménager.
Cela pourrait causer des explosions ou des incendies.
Remettez toutes les commandes à la position « OFF »
(arrêt) après avoir utilisé la fonction de programmation
de la minuterie.
Contrairement à celle de certaines cuisinières, la
table de cuisson n’est pas amovible. Ne tentez pas de
retirer cette table de cuisson.
Instructions particulières pour les appareils installés dans
l’État du Massachusetts :
Cet appareil ne peut être installé dans l’État du
Massachusetts que par un plombier ou un monteur
d’installations au gaz qualié de cet État. Si vous utilisez un
raccord de gaz exible, celui-ci ne doit pas excéder 0,91 m
(3 pi) de longueur. Un robinet de gaz manuel en « T » doit
être installé à la conduite de gaz qui est branchée à cet
appareil.
17
INSTRUCTIONS D’INSTALLATION 30” CUISINIÈRE À GAZ AUTONOME
1. Dégagements et dimensions
a. Prévoyez des dégagements adéquats entre la cuisinière et les surfaces combustibles adjacentes.
b. Emplacement: vériez l’emplacement la plage sera installée. Vériez l’alimentation électrique et l’alimentation en gaz et la stabilité du sol.
c. Les dimensions afchées doivent être utilisées. Les dimensions données fournissent un dégagement minimum. La surface de
contact doit être solideand level.
MUR
OU
ARMOIRE
MUR
OU
ARMOIRE
Espace ouvert
pour le gaz
Ubicación de gas
Cet espace
doit
reste clair
5”
30” Minimum*
Minimum to
wall on either
side of range
above 36” height.
36”
18”
Minimum to
cabinets on
either side
of range
25” Max.
13”
Maximum depth
for cabinets
above range top.
0” clearance below cooking top and at rear of range
Typical cabinet installationFront
view
Side
view
30”
Minimum
30”
Minimum
*ESPACE MINIMUM DE 76,2 CM (30”) ENTRE LE DESSUS
DE LA SURFACE DE CUISSON ET LE DESSOUS D’UNE
ARMOIRE EN BOIS OU EN MÉTAL NON PROTÉGÉE, OU
ESPACE MINIMUM DE 61 CM (24”) SI LE FOND DE L’ARMOIRE
EN BOIS OU EN MÉTAL EST PROTÉGÉ PAR UN PANNEAU
RÉSISTANT AU FEU D’AU MOINS 0,64 CM (1/4”) RECOUVERT
D’UNE FEUILLE D’ACIER DOUX DONT L’ÉPAISSEUR EST AU
MOINS DE 0,038 CM (0,015”) SI EN ACIER INOXYDABLE; DE
0,061 CM (0,024”) SI EN ALUMINIUM OU DE 0,051CM (0,020”)
SI EN CUIVRE. AUCUN ESPACE EST REQUIS À L’ARRIÈRE.
RESPECTEZ TOUTES LES DIMENSIONS INDIQUÉES CI
DESSUS AFIN D’ÉVITER DES DOMMAGES À LA PROPRIÉTÉ,
DE CRÉER UN DANGER POTENTIEL D’INCENDIE ET DE
FAIRE DES DÉCOUPAGES INCORRECTS DU COMPTOIR
ET DE L’ARMOIRE.
POUR ÉLIMINER LE RISQUE DE BRÛLURES OU D’INCENDIE
EN ATTEIGNANT LES UNITÉS DE SURFACE CHAUFFÉES,
L’ESPACE DE RANGEMENT DE L’ARMOIRE SITUÉ AU-
DESSUS DES UNITÉS DE SURFACE DOIT ÊTRE ÉVITÉ.
SI LE STOCKAGE DE L’ARMOIRE DOIT ÊTRE FOURNI, LE
RISQUE PEUT ÊTRE RÉDUIT EN INSTALLANT UNE HOTTE
DE CUISINIÈRE QUI SE PROJECTE HORIZONTALEMENT À
UN MINIMUM DE 5 “(127 mm) AU-DESSUS DU FOND DES
ARMOIRES.
Ne tentez pas d’utiliser les allumeur
électrique du four durant une panne de courant. Replacez
la commande du four à la position arrêt lorsqu’une panne
de courant survient. Les allumeurs électriques tenteront
de redémarrer le four lorsque le courant reviendra si la
commande a été laissée en marche. Lorsqu’une panne
de courant survient, les brûleurs de surface continuent de
fonctionner. S’ils ne sont pas en marche, ils peuvent être
allumés manuellement. Tenez une allumette allumée près
du brûleur et tournez lentement le bouton de ce brûleur à la
position LITE. Soyez très prudent.
29
7
/
8
"
Maximum
36
5
/
8
"
±
1
/
4
"
26
6
/
8
"
47"
porte ouverte
8"
4
1
/
3
"
12
1
/
16
"
24
1
/
8
"
22
5
/
8
"
4"
6
1
/
2
"
Fig.1
Fig.2
Fig.3
Vue de
face
Vue de
côté
Installation de cabinet typique
Minimum au mur
de chaque côté
de la plage
au-dessus
de 36” de
hauteur
Minimum aux
armoires de
chaque côté de
la cuisinière
Profondeur
maximale pour
les armoires
au-dessus de la
cuisinière
Dégagement sous le dessus de cuisson et à
l’arrière de la cuisinière
18
INSTRUCTIONS D’INSTALLATION 30” CUISINIÈRE À GAZ AUTONOME
2. Outils requis
Fig. a
(Porter des lunettes de sécurité lors de l’utilisation d’outils):
Pour les pattes de nivellement et le support anti-bas-
cule:
Clé à molette ou princes multiprises (Fig. a)
5/16” tournevis à douille ou tournevis à tête plate (Fig.
b)
Perceuse & foret de 1/8 diamètre (Si installer dans le
béton, foret de maçonnerie de 5/32”) (Fig. c)
Niveau (Fig. d)
Pour la connexion au gaz:
Clé à tuyau (Figs. a & e)
Pour l’ajustement de la amme:
Tournevis à tête Phillips et à tête plate (Figs. f & g)
Matériel supplémentaire:
Scellant à joints résistant au gaz propane (Fig. h)
Valve d’arrêt pour la ligne de gaz (Fig. i)
Un nouveau conduit exible pour appareil
électroménager design certié par CSA (½” NPT x
¾” ou ½” I.D.). Étant donné que les tuyaux solides
restreignent le déplacement de l’appareil, nous
recommandons d’utiliser un conduit exible (4 -5
pieds de long) pour toute nouvelle installation et
réinstallation.(Fig. k)
Matériaux fournis avec l’appareil:
Anti-Tip Modèle (Fig. l)
Support Anti-Tip; comprend 2 vis de montage (Fig. m)
Outils
Fig. f
Matériaux
Fig. h
Fig. i
Fig. j
Fig. k
Fig. d
Fig. c
Fig. g
Fig. b
Fig. e
Fig. l
Fig. m
Matériaux fournis avec l’appareil
19
INSTRUCTIONS D’INSTALLATION 30” CUISINIÈRE À GAZ AUTONOME
B. Percez les trous d’alignement et xez le support - Percez
un trou de 3 mm (1/8”) aux endroits les vis seront
localisées. Percez un trou d’alignement à un angle
descendant d’approximativement 20º si le support doit être
installé sur le mur. Percez
un trou d’alignement de
4 mm (5/32”) par 44 mm
(1-3/4”) de profondeur si
le support doit être installé
dans la maçonnerie ou des
planchers de céramique.
Les vis fournies peuvent
être utilisées dans le bois
ou des matériaux en béton.
Utilisez un serre écrou ou un
tournevis plat an de xer le
support en place.
C. Mise en place et à niveau de la cuisinière - Mettez la cuisinière
à niveau en ajustant les (4) pattes de mise à niveau à l’aide
d’une clé à molette. Note : Un espacement minimum de 3
mm (1/8”) requis entre le bas de la cuisinière et la patte
d’ajustement an de permettre un espace pour le support.
Utilisez un niveau à bulle pour vérier vos ajustements.
Glissez la cuisinière vers sa position. Vériez visuellement
que la patte de mise à niveau arrière est complètement
insérée et xée dans le support de contre-renversement
en retirant le panneau inférieur ou le tiroir de rangement.
Saisissez la partie supérieure arrière de la cuisinière et
essayez prudemment de la faire basculer vers l’avant, pour
les modèles possédant un tiroir-réchaud ou une rôtisserie.
3. Instructions d’installation du
support anti-basculement
Avertissement de sécurité important
La cuisinière doit être xée au plancher pour éviter qu’elle ne se
renverse. Ceci se réalise en installant un support anti-bascule à
l’aide des vis fournies avec la cuisinière. Si le support n’est pas
installé, la cuisinière peut basculer lorsqu’un poids excessif est
exercé sur une porte ouverte ou qu’un enfant monte dessus. Des
blessures graves peuvent s’ensuivre provenant de la cuisinière
elle-même ou du renversement de liquides chauds.
S’il faut déplacer la cuisinière à un autre endroit, le support
doit aussi être enlevé et réinstallé au nouvel emplacement.
Les instructions fournies sont prévues pour l’installation dans le
bois ou dans le béton, dans le plancher. Lors de l’installation,
assurez-vous que les vis ne pénètrent pas dans un câblage
électrique ou des accessoires de plomberie.
A. Situez le support en utilisant le gabarit- (Le support peut
être localisé à gauche ou à droite de la cuisinière. Utilisez
l’information donnée ci-après pour situer le support si le
gabarit n’est pas disponible.) Marquez le plancher ou le
mur à l’endroit le côté gauche ou droit de la cuisinière
sera situé. Vous pouvez utiliser la méthode de montage au
mur ou au plancher si l’arrière de la cuisinière est appuyé
au mur ou pas plus éloigné du mur que 32 mm (1 1/4”)
après installation. Enlevez la moulure ou xez le support au
plancher si une moulure est installée et ne permet pas au
support de s’appuyer fermement sur le mur. Pour un montage
contre le mur, situez le support en plaçant la partie arrière
du gabarit contre le mur arrière et le bord du gabarit sur la
marque faite qui identie le côté de la cuisinière. Placez le
support par-dessus le gabarit et identiez l’emplacement des
trous des vis dans le mur. Fixez le support au plancher si
l’arrière de la cuisinière est plus éloigné que 32 mm (1 1/4”)
du mur après l’installation. Situez le support en plaçant la
partie arrière du gabarit à l’endroit l’arrière de la cuisinière
sera localisé pour un montage sur le plancher. Marquez
l’emplacement des trous des vis indiqués sur le gabarit.
Fig. 4
Fig. 5
Fig. 6
Fig. 7
(17 mm)
Glissez la
cuisinère
en place
Côté de
la cuisinière
(32 mm)
(32 mm)
(32 mm)
(32 mm)
20
INSTRUCTIONS D’INSTALLATION 30” CUISINIÈRE À GAZ AUTONOME
Fig. 9
Veillez à stabiliser le côté gauche du détendeur de
gaz avant de serrer TOUS les autres raccords qui lui
sont rattachés. Empêchez le détendeur de s’ouvrir
lorsque vous effectuez le serrage des raccords (voir
g. 9).
Fig. 8 - Branchement de l’alimentation
Flare union
adaptateur
Appareil exible
conduit
Manuel
éteindre
soupape
Pression
régulateur
4. Prévoir une alimentation en
gaz adaptée
Remarque : Si l’altitude est supérieure à 610 m (2 000 pi), les
caractéristiques nominales de l’appareil doivent être réduites
de 4 % pour chaque tranche de 305 m (1 000 pi) d’altitude
au-dessus du niveau de la mer.
Cette cuisinière est préréglée pour fonctionner au moyen
d’une pression au collecteur de 10,2 cm (4 po). Un détendeur
convertible est raccordé au collecteur et DOIT être branché
en série avec la conduite d’alimentation en gaz. Si vous
utilisez le nécessaire de conversion au gaz propane/GPL,
suivez les instructions fournies dans ce nécessaire pour faire
la conversion du détendeur.
Lors de l’installation de la cuisinière, il est important de
s’assurer que le débit d’air nécessaire à la combustion et à la
ventilation n’est pas obstrué.
Pour assurer le bon fonctionnement de la cuisinière, la
pression d’admission maximale allant vers le détendeur ne
doit pas dépasser 35,6 cm (14 po) par rapport à la colonne
d’eau. La pression d’admission allant vers le détendeur doit
être supérieure d’au moins 2,5 cm (1 po) à la pression au
collecteur du détendeur.
Exemple : Si le détendeur est réglé à une pression au
collecteur de 10,2 cm (4 po) pour le gaz naturel, la pression
d’admission doit être d’au moins 12,7 cm (5 po); si le
détendeur a été converti au gaz propane/GPL et est réglé à
une pression au collecteur de 25,4 cm (10 po), la pression
d’admission doit être d’au moins 27,9 cm (11 po).
Veuillez procéder à la détection des fuites en suivant les
instructions de l’étape 4g.
La conduite d’alimentation en gaz doit être d’un diamètre
intérieur de 1,3 cm (1/2 po) ou de 1,9 cm (3/4 po).
5. Boucher les ouvertures qui
se trouvent dans le mur
Après avoir installé la conduite d’alimentation en gaz,
bouchez toutes les ouvertures qui se trouvent dans le mur
situé derrière la cuisinière ainsi que ceux se trouvant dans la
partie du plancher située sous la cuisinière.
6. Raccorder la cuisinière à la
conduite d’alimentation en gaz
Remarque :Pour éviter les fuites, utilisez de la pâte à joint
pour tuyau sur tous les raccords de tuyau de type mâle
(vers l’extérieur). Empêchez le détendeur de gaz de s’ou-
vrir lorsque vous effectuez le serrage des raccords.
a. Installez un robinet d’arrêt manuel externe sur la conduite
d’alimentation en gaz dans un endroit accessible situé
à l’extérieur de la cuisinière. Assurez-vous de connaître
l’endroit où se trouve le robinet d’arrêt ainsi que la façon
d’arrêter l’alimentation en gaz de la cuisinière (voir g. 8).
Flare union
adaptateur
b. Installez un adaptateur à raccord-union de 1,3 cm
(1/2 po) sur le détendeur sans serrer à plus de 15 pi/lb
(voir g. 8).
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Frigidaire FFGH3054UB Manuel utilisateur

Catégorie
Micro-ondes
Taper
Manuel utilisateur