If the information in this manual
is not followed exactly, a fire or
explosion may result causing
property damage personal injury
or loss of life.
Installation and service must be
performed by a qualified installer,
service agency or gas supplier.
Improper Installation, adjustment,
alteration, service or maintenance
can cause injury or property
damage.
Read the installation, operation
and maintenance instructions
thoroughly before installing or
servicing this equipment.
Save these instructions for
future reference. If you are
assembling this unit for
someone else, give this manual
to him or her to read and save
for future reference.
! !
IMPORTANT WARNING
SAVE THESE
INSTRUCTIONS
!DANGER
If you smell gas:
2. Extinguish any open flame.
1. Shut o gas to the appliance.
3. If odor continues, keep away from the appliance and
immediately call your gas supplier or fire department.
!
!
WARNING
WARNING
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
An LP-cylinder not connected for use should be
stored in vicinity of this or any other appliance.
For outdoor use only. DO NOT use
for cooking. DO NOT use under any
overhead enclosure.
USC
For Technical Support Please Contact Real Flame® At: 1-800-654-1704
T0004-MGO
LOT#________
PO#________
Gray Ledgestone Fire Column Owners Manual
!DANGER
This appliance can produce carbon
monoxide which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed
space such as a camper, tent, car or home.
CARBON MONOXIDE HAZARD
TABLE OF CONTENTS
Important Safety Information
Propane (LP) Dangers and Warnings
Parts List
Assembly Instructions
Lighting Instructions
Care and Cleaning
Gas Component Checks
Troubleshooting
Warranty
3
5
7
8
13
14
15
16
18
2
IF YOU SMELL GAS
• Do not try lighting any appliance.
• Extinguish any open flame.
• Shut off gas supply to the fire column.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
WARNING Failure to follow the dangers, warning and cautions in this manual may
property.
result in serious bodily injury or death, or in a fire or explosion causing damage to
• IMPORTANT NOTICE Read and understand all warnings and precautions prior to
alteration, service or maintenance can cause injury or property damage.
• Note The use and installation of this product must conform to local codes. In the
absence of local codes, use the National Fuel Gas Code, ANSI Z21.97. Reference to
Natural Gas and Propane Installation code CSA B149.1 or Propane Storage and
Handling code B149.2.
Minimum Clearance from Unit to Combustible Materials
72”(182.9cm) from the top; 48” (121.9 cm) from all sides and back. Do not locate this
fire column under any overhead enclosure.
supply piping system during any pressure testing of that system at test pressures in
excess of 1/2 of psi (3.5 kPa). The appliance must be isolated from the gas supply
testing of the gas supply piping system at test pressures equal to or less than 1/2 psi
(3.5 kPa).
Keep these instructions for future reference. If you are assembling this unit for someone
This gas fire column and its individual shuto valve must be disconnected from the gas
This gas fire column must be used ONLY outdoors in a well-ventilated space and shall NOT
else, give this manual to him or her to read and keep for future reference.
be used inside a building, garage, or any other enclosed area.
fumes can accumulate and cause asphyxiation.
• Children should be alerted to the hazards of high surface temperatures and kept at a
(7.62m) of this or any other appliance.
• Do not store any combustible materials in the base enclosure.
The use of alcohol, prescription or non-prescription drugs may impair an individual’s
IMPORTANT SAFETY INFORMATION
!WARNING FIRE COLUMN IS FOR OUTDOOR USE ONLY
3
• Always use in accordance with all applicable local, state and national codes. Contact your local
• DO NOT burn solid fuels such as: wood, charcoal briquettes, lump charcoal, manufactured
logs, driftwood, trash, leaves, paper, cardboard, plywood, painted or stained or pressure
securely fastened and tightened.
is in operation.
combustible constructions. Avoid using near or under overhanging trees and shrubs.
rock or stone. An asphalt or blacktop surface may not be acceptable for this purpose.
system and any gas control which has been under water.
• DO NOT use in windy conditions.
touch hot surfaces until the unit has cooled unless you are wearing protective gear such as
insulated pot holders or heat resistant gloves or mittens to avoid burns.
• Use only the gas assembly provided. The replacement gas assembly shall be that specified by
the manufacturer.
• Always disconnect the LP tank when the unit is not in use.
• Glass beads are very hot; please keep the children or pets away at a safe distance.
abrasion or wear by looking through the access panel. If if any part is damaged, it must be
IMPORTANT SAFETY INFORMATION (continued)
4
5
Before each use, remove the glass beads. Examine the burner and its components. If dirty,
clean with a soft brush and soapy water solution. Examine the area around the burner;
any dirt or foreign material, such as spider webs or nests in this area should be removed.
assembly cannot be replaced. Please contact Real Flame at 1-800-654-1704 for technical support.
LP GAS
characteristics before using any LP gas product.
Propane Characteristics
• Flammable, explosive under pressure, heavier than air and settles in pools in low areas.
• In its natural state, propane has no odor. For your safety, an odorant has been added.
Contact with propane could burn your skin.
LP GAS WARNINGS
Cylinders must be stored outdoors in a well-ventilated area out of reach of children.
• Disconnected cylinders must have threaded valve plugs tightly installed and must not be
stored in a building, garage or any other enclosed area.
• Never use a propane cylinder with a damaged body, valve, collar or footing.
• Dented or rusted propane cylinders may be hazardous and should be checked by your
propane gas supplier.
• Be sure to use only one 1 lb (465 g) LP gas cylinder in this appliance.
• Only tanks marked “propane” may be used.
The LP gas supply tank must be constructed and marked in accordance with the
the National Standard of Canada, CAN/CSA-B339, LP gas tanks, Spheres and Tubes for
the Transportation of Dangerous Goods; and Commission.
• LP gas tank must be arranged for vapor withdrawal.
Type I (CGA810) LP gas tank connection.
the operations manual will void manufacturer warranty.
IMPORTANT SAFETY INFORMATION (continued)
PROPANE (LP) DANGERS AND WARNINGS
!WARNING
serious personal injury, or property damage.
6
Gas Cylinder Valve Outlet and Inlet Connection, ANSI/CGA-V-1-1977, CSA B96.
• Never use an LP gas tank with a damaged body, valve, collar, or footing. Dented or rusted
LP gas tanks may be hazardous and should be checked by your LP gas supplier prior to
use.
The LP gas tank should not be dropped or handled roughly.
Tanks must be stored outdoors out of the reach of children. Do NOT store in a building,
garage, or any other enclosed area.
• Never store your LP gas tank where temperatures can reach over 125°F.
• Do not store the LP gas cylinder in direct sunlight or near a source of heat or combustion.
to increase, which may open the relief valve and allow gas to escape.
• Place dust cap on valve outlet whenever the LP gas tank is not in use. Only install the
type of dust cap on the LP gas tank valve outlet that is provided with the LP gas tank
valve. Other types of caps or plugs may result in leakage of propane.
a. Do not store a spare LP gas cylinder under or near this appliance.
serious injury may occur.
The pressure regulator is set for 11 inches of water column (pressure).
The maximum inlet gas pressure for this appliance is 14 inches of water column pressure.
• Never attempt to attach this appliance to the self-contained LP gas system of a camper trailer,
motor home or house.
• Always use the gas assembly provided with the appliance to connect to a LP gas cylinder. Never
connect to an unregulated LP gas supply. For technical support contact Real Flame at 1-800-654-1704.
• Hand turn the 1 lb LP gas tank. Never use tools. If the tank will not turn by hand, do not
Connecting your gas cylinder
Before connection, be sure that there is no debris caught in the head of the gas cylinder, head of
the regulator valve or in the head of the burner and burner ports. Connect screw on the 1 lb LP
PROPANE (LP) DANGERS AND WARNINGS
7
PARTS LIST
Ledgestone Column 1
118027402
Glass panes 4
Feet 06000003 4
Door
1Glass Beads 118006525
1
1
2
3
4
5
118000003
N/A
5
4
6
3
6
Glass Hardware Kit 118020007 4
1
2
ASSEMBLY INSTRUCTIONS
1
Insert the glass panes (3) into the corner brackets (7).
Secure the glass into place by tightening the screws with a screwdriver. Do not
overtighten the screws.
3
3
33
6
6
8
Check to make sure there is no debris in the head of the LP gas
tank or in the head of the regulator valve. Make sure you check the
burner and burner ports as well.
Connect the tank to the valve by threading clockwise. Hand tighten
only. Disconnect when not in use.
Connecting the LP Gas Tank
ASSEMBLY INSTRUCTIONS
2
9
10
3
ASSEMBLY INSTRUCTIONS
Place glass beads by hand. DO NOT dump bag out into tray to avoid
clogging the burner with dust. Position the glass beads (1.2kgs) to a
level about 1” above the top of the burner.
4
Check for leaks at these locations
!
!
WARNING Before using this outdoor fire column, make
WARNING Failure to inspect this connection or
sure you have read, understand and are following all
information provided in the Important Safety Information
section of this manual. Failure to follow those instructions
can cause death, serious injury or property damage.
follow these instructions could cause a fire or an
explosion, which can cause death, serious bodily
injury, or damage to property.
Prior to each gas fire column operation, check the valve
assembly for evidence of excessive abrasion or wear
though the access panel on the side of the base. Replace
the access panel prior to operating fire column.
BURNER CONNECTIONS
Make sure all of the connections are tight. If your unit
was assembled for you, visually check all connections.
Please refer to diagram for proper installation.
If any part appears to be incorrect please contact Real
Flame at 1-800-654-1704 for assistance.
CHECKING FOR LEAKS
Make a leak check solution by mixing 1 part dish
washing soap with 3 parts water in a spray bottle.
Make sure control knob is “OFF.” Then, attach the 1 lb
LP gas tank.
Spray leak solution on valve connections paying
particular attention to the areas indicated by arrows.
If any bubbles appear turn LP gas tank OFF,
reconnect and re-test. If you continue to see bubbles
after several attempts, disconnect LP gas source and
contact Real Flame at 1-800-654-1704 for assistance.
If no bubbles appear after one minute turn tank OFF,
wipe away solution and proceed.
PRE-USE INSTRUCTIONS
11
12
5
Using a Long Match or Lighter
1. Prior to lighting, use a shovel to move crushed glass for access to the burner.
2. Wearing heat resistant gloves, position the burning long match or burning butane
lighter near the side of long match or burning butane lighter near the side of
the burner. DO NOT lean over the fire column while lighting!
3. Turn control knob counterclockwise to “LIGHT”.
4. Remove long match/long butane lighter.
5. After lighting, use a shovel and heat resistant gloves to carefully move the crushed glass back
into the proper position and replace the glass panel.
6. After lighting, rotate the Burner Control Knob counter clockwise to “Low” setting. Observe
flame, make sure all burner ports are lit. Flame height should be no higher than 13 inches tall.
7. Adjust the flame to the desired height with the control knob.
When using this method to light yourre column use heat resistant gloves and follow the step by step
instructions. Failure to do so could result in severe injury.
If burner flame goes out during operation, immediately turn the control knob “OFF” and let the gas
clear a minimum of 5 minutes before attempting to re-light the fire column.
Please refer to the trouble shooting pages for additional support beginning on page 15.
!
!WARNING
WARNING
LIGHTING INSTRUCTIONS
13
WARNING DO NOT inspect this outdoor fireplace until the fire is COMPLETELY out.
WARNING DO NOT move or store this fire column unless the fire is COMPLETELY out and
cool to the touch.
WARNING DO NOT tamper with this appliance. This is DANGEROUS and will void the
warranty. Any part found to be faulty must be replaced with an approved part, confirmed by
manufacturer. For technical support contact Real Flame at: 1-800-654-1704.
!
!
!
Inspecting
This outdoor fire column must be inspected regularly to insure that the product is
safe to use and to extend product life.
1. Check the burner to make sure it is securely in place.
2. Check the Venturi tube to make sure it is clear and free of insects, spider nests and other debris.
3. Check all gas connections for leaks.
4. Check ignition system to insure proper sparking.
5. Check components for any signs of damage, rust or excessive wear.
6. If damage to any component is detected, DO NOT operate until the proper repairs have been
made.
1. Remove tank and store in a cool, dry location outdoors, away from children.
2. Carefully remove rock filler and store components flat to protect them from breakage.
3. ALWAYS cover your outdoor fireplace when not in use with the cover provided with the unit.
4. Store in a cool, dry location away from children and pets.
General Care and Cleaning
This outdoor fireplace should be cleaned regularly to ensure safe use and extend product life.
Note: After repeated use, a slight discoloration of the finishes may occur.
Column
1. Wipe exterior surfaces with a mild dish washing soap or baking soda, then rinse clean with
water.
Stainless Steel
1. For general cleaning use warm water, soap, ammonia, or detergent apply with a soft cloth or
sponge.
2. For finger prints or smears use 3M Stainless Steel Cleaner and Polish, Arcal 20, Lac-O-Nu,
LuminWash, O’Cedar Cream Polish, or Stainless Shine, this will provide a barrier file to
minimize fingerprints.*
3. For stubborn stains and discoloration use 3M Stainless Steel Cleaner and Polish, Allchem
Concentrated Cleaner, Samae, Twinkle, Cameo Copper Cleaner, Liquid Nu Steel, Coppers or
Revere Stainless Steel Cleaner, apply using a soft cloth in the same direction of the polish
lines.*
* Use of proprietary names is intended only to indicate a type of cleaner and does not constitute endorsement. Omission of any
proprietary cleanser does not imply its inadequacy. All products should be used in strict accordance with instructions on package.
Storage
CARE AND CLEANING
14
Possible Cause 1: No Gas Flow.
-Check if the LP gas tank is empty. If empty, replace the tank. If the propane
tank is not empty, refer to “Problem: Sudden drop in gas flow” on the
following page.
Possible Cause 2: 1 lb tank not fully connected.
-Turn the tank about one half to three fourths a turn, until you
feel a solid stop. Do not use tools, tighten by hand only.
Possible Cause 3: Burner ports clogged or blocked.
-Reference “Problem: Irregular flame pattern” on the
following page. Clean the burner ports as described
there.
TROUBLESHOOTING
For Technical Support Contact Real Flame at: 1-800-654-1704
Problem: The fire column emits a lot of black smoke when in use
Problem: Burner will not light with match
Possible Cause: Flame is being obstructed at burner ports.
-Make sure that the gas ports on the burner are free
of any glass beads so that the flame can flow naturally.
Burner
Ports
Possible Cause 1: Out of gas.
-Call your local gas company.
Possible Cause 2: Excess flow safety device may have been activated.
- Turn control knob to “OFF”, wait 30 seconds and light outdoor fireplace. If
the control knob and disconnecting the 1 lb LP tank. Turn burner
Reconnect the tank and perform a leak check at tank connection. Wait 30 seconds
and light the fire column.
Problem: Sudden drop in gas flow, or a reduced flame height
15
16
Possible Cause: Burner ports are clogged or blocked.
-Clean burner ports. Do this by inserting a
paperclip into each of the burner ports to
ensure they are not clogged. WARNING: Make
sure burner is not on and the gas supply has
been properly disconnected. Allow 15 minutes
for unit to cool before touching it.
If these troubleshooting steps are unable to resolve the problem,
please call Real Flame at: 1-800-654-1704
Possible Cause 1: High or gusting winds.
-Increase flame to “HIGH” setting.
Possible Cause 2: Low on LP gas.
-Replace LP gas tank.
Possible Cause 3: Excess flow valve tripped.
-Refer to “Problem: Sudden drop in gas flow”
Possible Cause 1: Ice has built up on the outside of the LP gas tank because the
vaporization process is too low.
-Turn the control knob to “OFF”. Replace with a spare LP gas tank and resume
burning. Store the spare LP gas tank in a well ventilated area, away from children.
Problem: Irregularame pattern,ame does not run the full length of the burner
Problem: Flame blow out
Problem: Flame seems to lose heat when burning in cold weather -
temperature below 50°F
TROUBLESHOOTING
Burner
Ports
Customer Service: 1-800-654-1704 in USA
Service à la clientèle: 1-800-363-6443 in Canada
custserv@realflame.com
Warranty & Return Policies
Real Flame®
7800 Northwestern Ave.
Racine, WI 53403
Warranty
Real Flame® Company warrants Real Flame gas fireplaces and accessories to be free from defects
in parts under normal use and service for a period of 1 year from the date of purchase and defective
from finish issues for a period of 2 years from the date of purchase. In the event of such defects Real
Flame will, at its option, replace the defective product or refund the purchase price. The foregoing
is the exclusive remedy and Real Flame disclaims all other warranties, including any implied
warranty or merchantability or firness for a particular purpose. In addition, Real Flame will not be
responsible for consequential damages in excess of the purchase price of the product on which
such liability is based.
Return Policy
You may return your purchase within 90 days of receipt. No refunds will be issued for incomplete
or unauthorized returns. All returned products must be 100% complete, adequately packaged in
original packaging and in resalable condition. Products that have been assembled or modified will
not be eligible for return. All items must be returned in their entirety, meaning all items included
must be returned together. No returns or exchanges on discontinued items. Please begin the return
process by contacting the store or company where you bought your Real Flame item.
Replacement Parts
In the event that an item has been lost or damaged, either by the manufacturer or in shipping, you
may request a replacement. Replacement parts are not available for all units and only given at Real
Flame’s discretion. We will assess any damage and find a solution, which could include shipping
you a replacement. No replacements are available for discontinued items or repackaged (open
box) products. Please call Real Flame Customer Service at 800-654-1704 for replacement parts
before returning the damaged item. Please have the following information
(which can be found in your instruction manual) ready before you call Customer Service.
• Model Number of Item
• 4-8 digit Part Number
• Lot Code Number
• Shipping Address
• A picture of the damaged item may be requested. Pictures should be
sent to custserv@realflame.com
Incorrect Order Received
If you received something other than what you ordered, please contact Real Flame Customer
Service at 800-654-1704 within 48 hours of receiving the item.
Please refer to www.Realflame.com for our complete return guidelines and policies.
RF General Warranty_052115
16
La négligence à suivre
scrupuleusement les instructions
contenues dans ce manuel peut
provoquer un incendie ou une
explosion occasionnant des
dommages à la propriété, des
blessures sérieuses et même la mort.
L’installation et l’entretien doivent
être faits par un installeur qualifié,
une compagnie d’entretien ou un
fournisseur de gaz.
Une installation, une mise au point,
une modification ou un entretien
inappropriés peuvent occasionner
des blessures ou des dommages à la
propriété.
Lire attentivement les instructions
concernant l’installation, l’utilisation et
l’entretien avant d’installer ou d’utiliser
l’appareil.
Garder ces instructions pour une
consultation future. Si vous assemblez
cet appareil pour quelqu’un d’autre,
lui donner le manuel pour lecture et
consultation futures.
!IMPORTANT !AVERTISSEMENT
!AVERTISSEMENT
CONSERVER CES
INSTRUCTIONS
!DANGER
Si vous percevez une odeur de gaz :
1. Couper l’alimentation en gaz de l’appareil.
2. Éteindre toute flamme nue.
3. Si l’odeur persiste, vous éloigner de l’appareil et
appeler immédiatement votre fournisseur de gaz ou le
service des incendies.
!AVERTISSEMENT
Ne pas entreposer ou utiliser d’essence, de vapeurs
ou liquides inflammables à proximité de cet
appareil ou de tout autre appareil.
Une bouteille de gaz PL non connectée et non
utilisée ne devrait pas être entreposée à proximité
de cet appareil ou de tout autre appareil.
Pour un usage extérieur exclusivement.
NE PAS utiliser pour la cuisson. NE PAS
utiliser sous une enceinte couverte.
USC
Pour le support technique S’il vous plaît nous contacter: 1-800-654-1704
Manuel d’utilisation de la colonne
T0004-MGO
2
!DANGER
Cet appareil peut produire du monoxyde
de carbone, lequel est toujours inodore.
Utiliser cet appareil dans un endroit fermé
peut causer la mort.
Ne jamais utiliser cet appareil dans un
espace fermé comme une fourgonnette
de camping, une tente, une voiture ou à
l’intérieur de la maison.
DANGER DE MONOXYDE DE CARBONE
TABLE DES MATIÈRES
Instruction de sécurité importante
Avertissements et dangers du Propane (PL)
Liste des pièces
Instructions pour l’assemblage
Instructions pour l’allumage
Soins et entretien
Vérifications entourant le gaz
Dépannage
Garantie
3
5
8
9
14
15
16
17
20
3
SI VOUS PERCEVEZ UNE ODEUR DE GAZ
Couper l’alimentation en gaz de la colonne-foyer.
• N’allumer aucun appareil.
Ne toucher aucun interrupteur électrique; n’utiliser aucun téléphone de l’immeuble.
• Appeler immédiatement un fournisseur de gaz d’un téléphone de votre voisinage.
• Suivre les instructions de votre fournisseur de gaz.
Si vous ne pouvez parler à votre fournisseur de gaz, appeler le service des incendies.
AVERTISSMENT La négligence à suivre les avertissements de danger et de précautions
de ce manuel peut occasionner des blessures corporelles sérieuses ou la mort ou
provoquer un incendie ou une explosion occasionnant des dommages à la proprié.
AVIS IMPORTANT Lire et comprendre tous les avertissements et toutes les
précautions avant de procéder à l’assemblage et à l’utilisation de votre colonne
inappropriés peuvent occasionner des blessures et des dommages à la propriété.
• Note L’utilisation et l’installation de ce produit doivent être conformes aux règlements
en vigueur dans votre région. En l’absence de règlements, utiliser les règlements
nationaux régissant l’utilisation du gaz ANSI Z21.97. Se reporter aux codes
d’installation du gaz naturel et du gaz propane (CSA B149.1) et à l’entreposage et la
manipulation du propane (B149.2).
Dégagement minimum de l’unité des matériaux combustibles
72” (182.9cm) du dessus; 48” (121.9 cm) de chacun des côtés et du derrière. Ne pas
installer cette colonne-foyer sous une enceinte couverte.
Cette colonne-foyer au gaz et sa soupape d’arrêt individuelle doivent être
débranchées du système d’alimentation en gaz durant les tests de pression de ce
système pour des tests de pressions au-delà de 1/2 psi (3.5 kPa). L’appareil doit être
isolé du système d’alimentation en gaz en fermant manuellement sa soupape d’arrêt
individuelle durant les tests de pression du système d’alimentation en gaz pour les
tests équivalant à 1/2 psi (3.5 kPa) ou moins.
Garder ces instructions pour une consultation future. Si vous assemblez cet appareil
pour quelqu’un dautre, lui donner le manuel pour une lecture et une consultation futures.
Cette colonne-foyer au gaz est conçue pour un usage extérieur SEULEMENT, dans un
endroit bien ventilé et ne doit PAS être utilisée dans un immeuble, un garage ou tout
autre endroit fermé.
• NE PAS utiliser cette colonne
TOXIQUES de monoxyde de carbone peuvent s’accumuler et provoquer une asphyxie.
• NE JAMAIS LAISSER cette colonne-foyer au gaz sans surveillance lors de son usage.
Les enfants devraient être prévenus des dangers de brûlures s’ils touchent les surfaces
très chaudes et devraient être tenus à une distance sécuritaire du feu lorsque la foyer
est en usage.
moins 25 pieds (7,62 m) de cet appareil ou de tout autre appareil.
• Ne pas entreposer de matériaux combustibles dans l’enceinte de la base.
L’utilisation d’alcool, de médicaments ou de drogues peut altérer les capacités d’un
individu et l’empêcher de bien assembler ou d’utiliser de façon sécuritaire cette
colonne-foyer extérieure
INSTRUCTION DE SÉCURITÉ IMPORTANTE
!LA COLONNE-FOYER EST CONÇUE
EXCLUSIVEMENT POUR L’EXTÉRIEUR
AVERTISSMENT
4
Mettre la colonne-foyer dans un endroit dégagé et libre de tous matériaux combustibles,
Cette colonne-foyer extérieure ne doit PAS être utilisée par des enfants. Les jeunes enfants
devraient faire l’objet d’une surveillance constante lorsqu’ils sont à proximité de la colonne
foyer extérieure.
Cette colonne-foyer extérieure ne doit pas être installée ou utilisée dans ou sur des véhicules
récréatifs et /ou sur des bateaux.
Toujours utiliser selon les règlements locaux, nationaux ou provinciaux en vigueur. Contacter le
service des incendies de votre locali pour connaître les détails concernant les feux extérieurs.
User avec cette colonne-foyer extérieure, des mêmes précautions que vous le feriez avec un feu
extérieur.
NE PAS brûler de combustibles solides tels que du bois, des briquettes de charbon, du
charbon de bois en blocs, des bûches manufacturées, du bois de grève, des déchets, des feuilles,
du papier, du contreplaqué, du bois traité peint ou teint dans cette colonne-foyer extérieure.
• NE PAS utiliser cette colonne-foyer extérieure avant qu’elle soit complètement assemblée et
• NE PAS entreposer un autre réservoir de gaz à moins de 10 pieds (3,05 m) de cette colonne-
foyer extérieure lorsqu’elle est en usage.
• NE PAS utiliser cette colonne-foyer extérieure près des voitures, des camions, des
fourgonnettes ou des véhicules récréatifs.
• NE PAS utiliser cette colonne-foyer extérieure sous des abris couverts ou près de
constructions combustibles non protégées. Éviter l’utilisation près ou sous les arbres et
les arbustes.
Toujours utiliser cette colonne-foyer extérieure sur une surface dure, de niveau et non
combustible comme le béton, la roche ou la pierre. L’asphalte et les revêtements
hydrocarbonés ne sont pas acceptables pour cet usage
• NE PAS utiliser cette colonne-foyer extérieure si des parties sont sous l’eau. Appeler
pièce ou système de commande et toute commande de gaz qui auraient été sous l’eau.
foyer extérieure.
• NE PAS utiliser par temps venteux.
Garder les rallonges électriques éloignées d’une colonne-foyer extérieure qui est chaude.
Certaines parties de cette colonne-foyer extérieure deviennent trop chaudes pour être
touchées lors de l’utilisation. Ne pas toucher les surfaces chaudes avant que l’appareil n’ait
refroidi, à moins que vous n’utilisiez un dispositif de protection comme des gants isolés pour
colonne-foyer au gaz.
Toute protection ou tout autre dispositif de sécurité enlevé lors de l’entretien courant doit être
replacé avant de réutiliser la colonne-foyer.
• NE PAS tenter de déplacer ou d’entreposer cette colonne-foyer extérieure avant que toutes les
pièces n’aient refroidi.
• NE PAS vous pencher au-dessus de cette colonne-foyer lorsque le feu est allumé ou qu’elle est
en usage.
• Utiliser seulement l'ensemble de gaz fournis avec l’appareil. L'ensemble de gaz de remplacement
ne devrait se faire que par ceux suggérés par le manufacturier.
• NE PAS tenter de déconnecter le régulateur de gaz du réservoir ou tout autre raccord de gaz
lorsque l’appareil est en usage.
INSTRUCTION DE SÉCURITÉ IMPORTANTE
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49

Real Flame T0004LP-GLS Mode d'emploi

Catégorie
Cheminées
Taper
Mode d'emploi