Modern Forms WS-54127 Cadence Mode d'emploi

Taper
Mode d'emploi
1
INSTALLATION INSTRUCTIONS
541-Bath Light
WS-54127/WS-54139
HARDWARE
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Nov. 2020
Wire Connector
Qty:3+1Extra
Mounting Screw
Qty:2+1 Extra
Plastic Anchor
Qty:4+2Extra
Wood Screw
Qty: 4+2Extra
Square Plate
Qty:2pcs
Wire Connector
Qty:2+1Extra
Round Plate
Qty:2pcs
Mounting Bracket A
Qty:1pc
Mounting Bracket B
Qty:2pcs
Driver
Qty:1pc
ABCDE
FGHIJ

• Read all instructions before installing.
• System is intended for installation by a licensed electrician in accordance with the National Electrical Code (NEC) and local regulations.
When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
• Retain installation instructions for future maintenance reference.
All parts must be used as indicated in these instructions. This product is designed for use only with the supplied parts and/or
accessories designated for use by dweLED. Substitution of parts or accessories not designated for use with this product by dweLED could
result in personal injury or property damage, and will void the warranty. Contact an authorized dealer or the manufacturer if any parts are
damaged or missing.
 Coastal conditions may cause mineral and residue build-up on the xture. We recommend that customers in coastal
areas clean all external surfaces of the xture once every two weeks with a wet cloth.
Pour éviter tout choc électrique, assurez-vous que le disjoncteur soit mis hors tension avant de commencer.
• Lisez toutes les instructions avant l’installation.
• Le système doit être installé par un électricien licensié conformément au code national de lélectricité (NEC), et également aux
règlements locaux.
• Lors de la manipulation du luminaire, n’appuyez pas sur les LED. Tenez-le uniquement par la base.
Toutes les pièces doivent être utilisées comme indiqué dans ces instructions. Ce produit est conçu pour être utilisé seulement
avec les pièces et/ou accessoires fournis pour être utilisés avec les produits dweLED. Remplacer des pièces ou accessoires non conçus pour ce
produit dweLED pourrait causer des dommages corporels ou matériels et pourrait également causer l’annulation de la garantie. Veuillez
contacter un revendeur autorisé ou le fabricant si des pièces manquent ou sont endommagées.
Les conditions côtières peut causer une accumulation de minéraux et de résidue sur le luminaire. Nous recommendons
aux clients qui resident dans les zones côtières de nettoyer toutes les surfaces externes du luminaire une fois toutes les deux semaines avec
un chion humide.
2
INSTALLATION INSTRUCTIONS
541-Bath Light
WS-54127/WS-54139
FIG. 1
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Nov. 2020
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
PREPARATION
1.
MOUNTING WITH JUNCTION BOX (Fig. 1)
4. Choose between a square or round plate (F orG).
Note:
thread the driver's output wire through the hole of the plate.
9. I
Note
DIMMING WIRING INFORMATION (Fig. 4)
Square/Round Plate
Junction Box Screw
Mounting Screw
Mounting Hole
Junction Box
Cover
LED Tube
Driver
Cross Bar
Wire Connector
House Wire
Wire Connector
Driver Output Wire
Ground Wire
A
F
J
B
C
E
Plastic Anchor
D
Wood Screw
Mounting Bracket B
Mounting Screw
C
Mounting Bracket A
H
I
Standard
Driver Input Wire
>4
Junction Box
Wall
12. This xture features electronic low voltage (ELV) or 0-10V dimming capabilities. See notes below for specic dimming wires information.
13. To utilize ELV dimming: use wires black (hot), white (neutral) and green ground wire (ground).
14. To utilize 0-10V dimming: use wire purple (dim+), pink or gray (dim-), black (hot), white (neutral) and green ground wire (ground).
滚滚长江东逝水
Purple - Dim+
Black - Hot
White - Neutral
Black - Output -
Red - Output +
3
INSTALLATION INSTRUCTIONS
541-Bath Light
WS-54127/WS-54139
FIG. 2
Fixture Wires
Black or
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
FIG. 3 Wiring
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Nov. 2020
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Mounting Backplate Dimension
FIG.4 Driver Wiring
MOUNTING WITHOUT JUNCTION BOX (Fig. 2)
insert the plastic anchors (D).
32
3d1.28
w"
Mounting Hole Dimensions
WS-54127 24
WS-54139 36
WS-54127 24
WS-54139 36
0.94
0.94
Access hole
Junction Box
0.45
Access hole Driver Output Wire
B
C
D
E
Standard
I
LED driver
Black - Hot
White - Neutral
Black - Output -
Red - Output +
Mounting hole
Plastic Anchor
Wood Screw
Wire Connector
Power feed
Mounting Screw
Cover
LED Tube
Mounting Bracket B
Mounting hole
Pink or Gray -Dim
Remote
LED
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JAN 2023 G0
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
INSTALLATION INSTRUCTION
Trimless Junction Box Cover
MKCP-3040-WT
OVERALL COMPONENT DIMENSIONS
CAUTION: TO PREVENT ELECTRICAL SHOCK, ENSURE ELECTRICITY HAS BEEN TURNED OFF AT THE CIRCUIT BREAKER BEFORE
BEGINNING.
-Read all instructions before installing.
-System is intended for installation by a licensed electrician in accordance with the National Electrical Code (NEC) and local regulations.
-When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
-Retain installation instructions for future maintenance reference.
WARNING: All parts must be used as indicated in these instructions. This product is designed for use only with the supplied parts and/or
accessories designated for use by Modern Forms. Substitution of parts or accessories not designated for use with this product by Modern Forms
could result in personal injury or property damage, and will void the warranty. Contact an authorized dealer or the manufacturer if any parts are
damaged or missing.
MISE EN GARDE: POUR ÉVITER TOUT CHOC ÉLECTRIQUE, ASSUREZVOUS QUE LE DISJONCTEUR SOIT MIS HORS TENSION AVANT DE
COMMENCER.
-Lisez toutes les instructions avant l’installation.
-Le système doit être installé par un électricien licensié conformément au code national de l’électricité (NEC), et également aux règlements
locaux.
-Lors de la manipulation du luminaire, n’appuyez pas sur les LED. Tenez-le uniquement par la base.
ATTENTION: Toutes les pièces doivent être utilisées comme indiqué dans ces instructions. Ce produit est conçu pour être utilisé seulement avec
les pièces et/ou accessoires fournis pour être utilisés avec les produits Modern Forms. Remplacer des pièces ou accessoires non conçus pour ce
produit Modern Forms pourrait causer des dommages corporels ou matériels et pourrait également causer l’annulation de la garantie. Veuillez
contacter un revendeur autorisé ou le fabricant si des pièces manquent ou sont endommagées.
COMPONENT OVERVIEW
The trimless junction box cover is intended for installation to NEC approved 4” square junction boxes recessed in drywall and ush with the
support structure. It may be covered with spackle and/or plaster to conceal junction box visibility. It is to be connected to compatible Modern
Forms xtures. Refer to specications sheets for more information.
2"
#8
TYP
HARDWARE
Wire Connector
Qty: 3 (+1 Extra)
½” Plastic Spacer
Qty: 2
⁄”-40 x 1⁄” Long
Mounting Screw
Qty: 2 (+1 Extra)
¾” Plastic Spacer
Qty: 2
A
D
B
E
#8-32 x ¾” Long
Junction Box Screw
Qty: 2 (+1 Extra)
1” Plastic Spacer
Qty: 2
C
F
NOTE: This accessory is supplied with an optional mounting C-ring for
xture connection via ⁄” K.O. hole. This component may be omitted
from the installation if mounting xtures using #8 screw holes.
2Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JAN 2023 G0
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
INSTALLATION INSTRUCTION
Trimless Junction Box Cover
MKCP-3040-WT
FIG. 1
FIG. 2
FIG. 4
TRIMLESS JUNCTION BOX COVER INSTALLATION:
The trimless junction box cover is compatible with NEC approved
4” square junction boxes recessed in drywall and ush with the
support structure.
1. Install compatible junction box (by others) to the framing
structure. Ensure the junction box is ush with the base or front
of framing structure (See FIG. 1).
2. Install the mounting plate to the junction box (See FIG. 2).
Ensure the spacer alignment base is facing outward.
FIG. 3
105mm
105mm
FIG. 5 FIG. 6
3. Determine the drywall thickness and select the appropriate
spacer to install between the mounting plate and the trimless
junction box cover (See FIG. 3).
NOTE: Only 1 matching pair of spacers are to be used per
installation.
4. Using the mounting screws provided, attach the trimless
junction box cover to the mounting plate (See FIG. 4).
5. Make a 4⁄” square cutout in drywall at the intended trimless
junction box cover location and proceed to install to framing
structure (See FIG. 5). Apply and nish spackle up to the center
hole of trimless junction box cover. Ensure #8 holes on the
cover are free of spackle. (See FIG. 6).
Mounting Plate
Plastic
Spacers
Trimless Junction Box Cover
Cover Mounting Screws
Ground Wire
Example: ½” Drywall (No Spacer)
⁄”½”
Spacer Alignment
Base
Spacer
Height
Drywall
Thickness
No Spacer ½”
½” ⁄”
¾” 1”
1” 1¼”
Junction Box
Screws
CB
D
E
F
3Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JAN 2023 G0
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
INSTALLATION INSTRUCTION
Trimless Junction Box Cover
MKCP-3040-WT
FIXTURE INSTALLATION TO JUNCTION BOX COVER:
The trimless junction box cover features two #8 holes which may be used to mount xtures:
1. Make appropriate splice connections. Wiring may be placed inside the xture or pushed into the junction box.
2. Using #8 mounting screws supplied with the lighting xture, attach the xtures to the #8 holes on the trimless junction box cover. Apply
xture cover or lensing (where applicable) to complete the installation. (See FIG. 7).
Fixture #8 Mounting Screws
FIG. 7
Wire Connector
A
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Modern Forms WS-54127 Cadence Mode d'emploi

Taper
Mode d'emploi