Introduction
Accessories
Thank you for choosing the enterprise Wi-fi 6 access point. This guide is designed to familiarize you
with the layout of the access point and describes how to deploy the access point in your network.
AP-N505
Mounting Bracket x1
Optional (Not Included)
Screw Anchor x4
Screw x4
UPUP
K K
1
EN
Anti-theft key x1
Ethernet Cable x1Portable Hammer Drill x1 Rubber Hammer x1 Screwdriver x1
K
Console 48V
Reset
2.5G SFP
2.5G SFP
LAN/1G/PoE
Hardware Overview
Ports
SFP Port
Port Description
LAN1/PoE
An uplink adaptive Ethernet port for service data transmission.
IEEE 802.3af standard PoE power supply.
DC adapter power supply.
SFP
Anti-theft lockhole
An uplink fiber optical port for service data transmission.
CONSOLE An RJ45 console port for serial management.
Connect to the anti-theft lock.
1G
1G
2.5G
2.5G
3G
1G
3G
1G
1G
1G
/
/
1G
1G
/
/
1G
1G
2.5G
2.5G
Anti-theft lockhole
Reset Button
ConsoleSFP
LAN1/PoE
2
EN
DC 48V
DC 48V
Rate
(SFP port)
Rate
(optical module)
Negotiated Rate of the Device
Optical
Port
LED
The device at the other end that connects to the SFP port of the AP can support both optical and
electrical port types.
1G 1G/10G/auto 1G/2.5G/10G/auto
LED
Button
Button Description
Reset Restore to Factory Default Settings: Press and hold the “Reset” button
for more than 3 seconds.
Restart: Press the “Reset” button for less than 2 seconds.
FIT AP
DescriptionState
Off
Blinking Green
Frequency
N/A
3Hz
N/A
3Hz
AP is not connected to the power supply, or AP is in
DND state, which can be closed by software.
Uboot program initialization in progress.
Main program initialization in progress.
Initialization is complete, but both Ethernet links
are down.
Solid Green
Blinking Red
NOTE: 1. The SFP port of AP does not support negotiated rate. When using the optical
module, the rates of the AP, the optical module and the device at the other end must be
the same.
2. The AP supports optical&electrical uplink port multiplexing. If optical and electrical
uplink ports connect to cables at the same time, the AP will preferentially select the optical
uplink port as the data transmission port (automatically disables the electrical uplink port).
When the optical uplink port cable is removed, the electrical uplink port automatically starts.
3
EN
1G
1G
2.5G
2.5G
2.5G
1G
2.5G
1G
1G
/
/ / /
//
1G
/
/
1G
2.5G
Rate
(SFP port)
Rate
(optical module)
Negotiated Rate of the Device
Electrical
Port
1G 1G/10G/auto 1G/2.5G/10G/auto
DescriptionState Frequency
N/A
3Hz
Initialization is complete, and AP is
establishing a CAPWAP.
Program update in progress under FIT Mode.
Do not power AP off.
AP is working normally and the CAPWAP is in
normal state. No wireless client is associated
with AP.
AP is working normally and the CAPWAP is in
normal state. At least one wireless client is
associated with AP.
N/A
3Hz
Solid Orange
2Hz AP location, used to locates the current AP
model( AP-N505E).
Double Blinking RED
Blinking Orange
Solid Blue
Blinking Blue
FAT AP
DescriptionState
Off
Blinking Green
Frequency
N/A
3Hz
N/A
3Hz
AP is not connected to the power supply, or
AP is in DND state, which can be closed by
software.
Uboot program initialization in progress.
Main program initialization in progress.
Initialization is complete, but both Ethernet
links are down.
Solid Green
Blinking Red
Solid Blue
3Hz AP is working normally. At least one wireless
client is associated with AP.
Blinking Blue
N/A AP is working normally. No wireless client is
associated with AP.
NOTE: Hz indicates the number of times a flashing light blinks per second.
4
EN
K
K
2.5G SFP
2.5G SFP
Console LAN/1G/PoE
48V
PoE
Status M1 M2 PWR1 PWR2 PoE
1 2 3 4 5 6 7 8 910 11 12 13 14 15 16 17 18 19 20 21 22 23 24
24 25 2623
Green=1000M Yellow=10/100M On=Link Flashing=ACT PoE LED:Green=Good Supply Yellow=Over Load
CONSOLE
SFP+
S3410-24TS-P
PoE+
29 30 31 32
25 26 27 28
13 14 15 16 17 18 19 20 21 22 23 24
Yellow=Over Load
5678910 11 12
On=Link Flashing=ACT PoE LED Mode:Green=Good SupplyYellow=100M
1234
Green=10G/5G/2.5G/1G
MGMT
SYS PWR FAN PoE
PoE FUNC
CONSOLE
Connect the LAN1/PoE port of the AP to a PoE switch with an Ethernet cable.
Installation
Connecting the PoE Power Supply
Installation Requirements
Install AP indoors. Do not power AP on during installation.
Ensure that the installation site is dry and flat.
Ensure that the installation position is secure enough.
Ensure that AP avoid liquid intrusion.
Ensure that the space around the installation position is enough to facilitate heat dissipation
and maintain(more than 0.4m).
Install AP in a well-ventilated position.
The working environment must maintain a certain temperature and humidity.
Keep AP clean and dust-free.
Keep AP away from high voltage cables.
Keep AP away from strong thunderstorms and electric field environment.
5
EN
S5860-24XB-U
Ceiling Mount
1. Drill 4 mounting holes of 6mm(0.24 in) diameter into the desired positions of ceiling with a center
distance of 53mm(2.09 in).
2. Insert screw anchors into each hole separately, hit and fix them with a rubber hammer.
3. Align the 4 holes at the back of the mounting bracket with the screw anchors and fix the screws to
the mounting bracket with a screwdriver.
6
EN
LAN/1G/PoE
ole
48V
2.5G SFP
2.5G SFP
K
K
Console 48V
Reset
2.5G SFP
2.5G SFP
LAN/1G/PoE
NOTE: 1. Connect the Ethernet cable before mounting the AP on the bracket.
2. The AP should be pushed into the buckle holes smoothly.
3. After mounting, check whether the AP is fixed.
4. The steps of wall mount are the same as the ceiling mount.
Installing the Optical Transceiver Module
1. Insert the module into the SFP port.
7
EN
4. Align the buckles behind the AP with the buckle holes of the mounting bracket and push the AP
into the holes in the opposite direction of the arrow to fix.
8
EN
UP
UP
KK
(Optional) Enabling the Anti-theft Lock
1. Remove the screws on the mounting bracket with a screwdriver and enable anti-theft lock.
UP
UP
K K
2. Insert one connector of a fiber cable into the module.
K
Console 48V
Reset
2.5G SFP
2.5G SFP
LAN/1G/PoE
UP
UP
KK
For both ceiling mount and wall mount, hold two sides of the AP and push it in the direction of the
network port to release it from the buckle holes.
Dismounting the AP
9
EN
2. Align the buckles behind the AP with the buckle holes of the mounting bracket and push the AP into
the holes in the opposite direction of the arrow to fix.
UP
UP
KK
Configuring the Access Point
Configuring the AP via the Web-based Interface
Step 1: Connect a computer to the business port of the AP using the network cable.
Step 2: Set the IP address of the computer to 192.168.1.x (“x” is any number from 2 to 254).
Step 3: Open a browser, type http://192.168.1.1 and enter the default user name and password
(both are admin”)
Step 4: Click Login to display the web-based configuration page.
Step 5: Click System Mode Switch to switch the FIT/FAP working mode.
Access Point
Login
admin
*****
?x
OK Cancel
General
IP address:
Subnet mask:
Default gateway:
You can get IP settings assigned automatically if your network
supports this capability. Otherwise, you need to ask your network
administrator for the appropriate IP settings.
Internet Protocol Version 4 (TCP/IPv4) Properties
Use the following IP address:
Obtain an IP address automatically
Preferred DNS server:
Alternate DNS server:
Validate settings upon exit Advanced...
. . . 21168192
0255
255255
. . .
. . .
. . .
. . .
Obtain DNS server address automatically
Use the following DNS server addresses:
10
EN
NOTE: The AP works in Fit AP Mode by default.
Configuring the AP via the Console Port (FAT AP Mode)
Step 1: Connect a computer to the AP’s console port using the console cable.
Step 2: Start the terminal simulation software such as “HyperTerminal” on the computer.
Step 3: Set the parameters of the “HyperTerminal”: 9600 bits per second, 8 data bits, no parity,
1 stop bit and no flow control.
Step 4: After setting the parameters, click Connect to enter. And then enter the password
(“admin by default).
Protocol: Serial
Flow Control
DTR/DSR
RTS/CTS
XON/XOFF
Save session
Open in a tab
Cancel
COM3
9600
8
None
1
Port:
Baud rate:
Data bits:
Parity:
Stop bits:
Name of pipe:
Show quick connect on startup
x
Quick Connect
The port may be manually entered or selected from the list.
Connect
Connect
x
System Mode
Fit AP Mode
AC
AP
AP
CLLENT
POE SW
Internet
Fit AP Mode
AP
ROUTER
CLLENT
POE SW
Internet
Current Mode: Fit AP Mode
NOTE: The device restarts after mode switch. please wait for a minute.
11
EN
NOTE: For more details, please refer to the Configuration Guide on the website.
Troubleshooting
The screen displays request timed out
1. Check whether the network cable is intact.
2. Check whether the hardware connection is correct.
3. Check whether the IP address setting of the computer is correct.
4. Check whether the indicators of AP and the computer are normal.
LED is off after the AP is powered on
1. For PoE power supply, check whether the power source is IEEE 802.11af/at compliant, or whether
the Ethernet cable is properly connected.
2. For DC adapter power supply, check whether the adapter is connected to an active power outlet,
or whether the adapter works properly.
Ethernet port is not working after connecting
Check whether the device at the other end of the Ethernet cable is working properly, the Ethernet
cable is capable of providing the required data rate, or it is properly connected.
Wireless client cannot find the AP
1. Check whether the power supply works properly.
2. Check whether the Ethernet port is properly connected.
3. Check whether the AP is correctly configured.
4. Move the client device to adjust the distance between the client and the AP.
12
EN
Online Resources
Download https://www.fs.com/products_support.html
Help Center https://www.fs.com/service/fs_support.html
Contact Us https://www.fs.com/contact_us.html
FS ensures our customers that any damage or faulty items due to our workmanship, we will offer
a free return within 30 days from the day you receive your goods. We will also offer free software
update service. This excludes any custom made items or tailored solutions.
Product Warranty
Warranty: The Wi-fi 6 wireless access point enjoys 3 years limited warranty against
defect in materials or workmanship. For more details about warranty, please check at
https://www.fs.com/policies/warranty.html
3
Return: If you want to return item(s), information on how to return can be found at
https://www.fs.com/policies/day_return_policy.html
13
EN
14
Einführung
Zubehör
Vielen Dank, dass Sie sich für den Enterprise Wi-fi 6 Access Point entschieden haben. Diese Anleitung
soll Sie mit dem Aufbau des Access Point vertraut machen und beschreibt, wie Sie den Access Point in
Ihrem Netzwerk einsetzen.
AP-N505
Montagehalterung x1
Optional (nicht im Lieferumfang enthalten)
Schraubanker x4Schraube x4
UPUP
K K
Anti-Diebstahl-Schlüssel x1
Ethernet-Kabel x1
Tragbare
Hammerbohrmaschine x1 Gummihammer x1 Schraubendreher x1
DE
15
K
Console 48V
Reset
2.5G SFP
2.5G SFP
LAN/1G/PoE
Hardware-Übersicht
Ports
SFP-Anschluss
Port Beschreibung
LAN1/PoE
Ein anpassungsfähiger Uplink-Ethernet-Port für die Übertragung
von Dienstdaten.
IEEE 802.3af-Standard PoE-Stromversorgung.
DC-Adapter zur Stromversorgung.
SFP
Anti-Diebstahl-Schloss
Ein Uplink-Glasfaser-Port für die Übertragung von Dienstdaten.
KONSOLE Ein RJ45-Konsolen-Port für die serielle Verwaltung.
Loch für Diebstahlsicherung.
1G
1G
2,5G
2,5G
3G
1G
3G
1G
1G
1G
/
/
1G
1G
/
/
1G
1G
2,5G
2,5G
Anti-Diebstahl-Schloss
Reset-Taste
KonsoleSFP
LAN1/PoE
DC 48V
DC 48V
Rate
(SFP Port)
Rate
(optisches Modul)
Ausgehandelte Rate des Geräts
Optischer
Port
LED
Das Gerät am anderen Ende, das an den SFP-Port des APs angeschlossen wird, kann sowohl optische
als auch elektrische Porttypen unterstützen.
1G 1G/10G/auto 1G/2.5G/10G/auto
DE
16
LED
Taste
Taste Beschreibung
Reset Die Werkseinstellungen zurücksetzen: Drücken Sie die Reset-Taste für
mehr als 3 Sekunden.
Neustart: Drücken Sie die Reset-Taste für weniger als 2 Sekunden.
FIT AP
BeschreibungStatus
Aus
Blinkend Grün
Frequenz
N/A
3Hz
N/A
3Hz
Der AP ist nicht an die Stromversorgung angeschlossen,
oder der AP befindet sich im DND-Zustand, der per
Software beendet werden kann.
Die Initialisierung des Uboot-Programms wird
durchgeführt.
Das Hauptprogramm wird gerade initialisiert.
Die Initialisierung ist abgeschlossen, aber beide
Ethernet-Links sind ausgefallen.
Durchgehend Grün
Blinkend Rot
HINWEIS: 1. Der SFP-Port des APs unterstützt keine ausgehandelte Rate. Wenn Sie das
optische Modul verwenden, müssen die Raten des APs, des optischen Moduls und des
Geräts am anderen Ende gleich sein.
2. Der AP unterstützt optisches und elektrisches Uplink-Port-Multiplexing. Wenn optische
und elektrische Uplink-Ports gleichzeitig mit Kabeln verbunden sind, wählt der AP
bevorzugt den optischen Uplink-Port als Datenübertragungsport aus (der elektrische
Uplink-Port wird automatisch deaktiviert).Wenn das Kabel des optischen Uplink-Ports
entfernt wird, wird automatisch der elektrische Uplink-Port aktiviert.
1G
1G
2,5G
2,5G
2.5G
1G
2,5G
1G
1G
/
/ / /
//
1G
/
/
1G
2,5G
Rate
(SFP Port)
Rate
(optisches Modul)
Ausgehandelte Rate des Geräts
Elektrischer
Port
1G 1G/10G/auto 1G/2.5G/10G/auto
DE
17
BeschreibungStatus Frequenz
N/A
3Hz
Die Initialisierung ist abgeschlossen, und der
AP baut ein CAPWAP auf.
Programmaktualisierung im FIT-Modus läuft.
Schalten Sie den AP nicht aus.
Der AP arbeitet normal und der CAPWAP
befindet sich im Normalzustand. Kein
drahtloser Client ist mit dem AP verbunden.
Der AP arbeitet normal und der CAPWAP
befindet sich im Normalzustand. Mindestens
ein drahtloser Client ist mit dem AP verbunden.
N/A
3Hz
Durchgehend Orange
2Hz Der AP-Standort dient zur Lokalisierung des
aktuellen AP-Modells (AP-N505E).
Zweimalig blinkend Rot
Blinkend Orange
Durchgehend Blau
Blinkend Blau
FAT AP
BeschreibungStatus
Aus
Blinkendes Grün
Frequenz
N/A
3Hz
N/A
3Hz
Der AP ist nicht an die Stromversorgung
angeschlossen, oder der AP befindet sich im DND-
Zustand, der per Software beendet werden kann.
Die Initialisierung des Uboot-Programms wird
durchgeführt.
Das Hauptprogramm wird gerade initialisiert.
Die Initialisierung ist abgeschlossen, aber beide
Ethernet-Verbindungen sind ausgefallen.
Durchgehend Grün
Blinkendes Rot
Durchgehend Blau
3Hz Der AP funktioniert normal. Mindestens ein
drahtloser Client ist mit dem AP verbunden.
Blinkendes Blau
N/A Der AP funktioniert normal. Kein drahtloser Client
ist mit dem AP verbunden.
HINWEIS: Die Frequenz gibt an, wie oft ein Blinklicht pro Sekunde blinkt.
DE
18
K
K
2.5G SFP
2.5G SFP
Console LAN/1G/PoE
48V
PoE
Status M1 M2 PWR1 PWR2 PoE
1 2 3 4 5 6 7 8 910 11 12 13 14 15 16 17 18 19 20 21 22 23 24
24 25 2623
Green=1000M Yellow=10/100M On=Link Flashing=ACT PoE LED:Green=Good Supply Yellow=Over Load
CONSOLE
SFP+
S3410-24TS-P
PoE+
29 30 31 32
25 26 27 28
13 14 15 16 17 18 19 20 21 22 23 24
Yellow=Over Load
5678910 11 12
On=Link Flashing=ACT PoE LED Mode:Green=Good SupplyYellow=100M
1234
Green=10G/5G/2.5G/1G
MGMT
SYS PWR FAN PoE
PoE FUNC
CONSOLE
Verbinden Sie den LAN1/PoE-Port des APs mit einem PoE-Switch über ein Ethernet-Kabel.
Installation
Anschließen des PoE-Netzteils
Installationsanforderungen
Installieren Sie den AP in einem Innenraum. Schalten Sie den AP während der Installation
nicht ein.
Stellen Sie sicher, dass der Installationsort trocken und eben ist.
Stellen Sie sicher, dass die Installationsposition sicher genug ist.
Achten Sie darauf, dass in den AP keine Flüssigkeit eindringt.
Stellen Sie sicher, dass der Platz um den Installationsort ausreichend ist, um die Wärmeabfuhr
zu erleichtern und zu gewährleisten (mehr als 0,4 m).
Installieren Sie den AP an einem gut belüfteten Ort.
Die Arbeitsumgebung muss eine bestimmte Temperatur und Luftfeuchtigkeit haben.
Halten Sie den AP sauber und staubfrei.
Halten Sie den AP von Hochspannungskabeln fern.
Halten Sie den AP von starken Gewittern und elektrischen Feldern fern.
DE
19
S5860-24XB-U
Deckenmontage
1. Bohren Sie 4 Montagelöcher mit einem Durchmesser von 6 mm (0,24 Zoll) an den gewünschten
Stellen der Decke mit einem Mittenabstand von 53 mm (2,09 Zoll).
2. Setzen Sie die Dübel in jedes Loch einzeln ein, fixieren Sie sie mit einem Gummihammer und
befestigen Sie sie.
3. Richten Sie die 4 Löcher auf der Rückseite der Montagehalterung mit den Dübeln aus und
befestigen Sie die Schrauben mit einem Schraubenzieher an der Montagehalterung.
DE
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

FS AP-N505 Mode d'emploi

Taper
Mode d'emploi

dans d''autres langues